Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
Add more filters










Publication year range
1.
Chemosphere ; 346: 140409, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37832893

ABSTRACT

Biomass, including municipal solid waste, and solar energy are two of the inevitable sources for future decarbonized energy systems. Fresnel lens thermal collectors using cheap micro-structured foils is an interesting emerging medium-temperature solar thermal design that might be of high practical value, provided that its fluctuating output is managed. This study proposes a hybrid solar-waste solution using this type of collector for multi-generation via an Organic Rankine Cycle. The cycle is specially designed for supplying low-grade heat, power, and industrial heat (which is a very critical sector to be decarbonized) taking advantage of the generated stable solar-waste medium-temperature heat at zero emission level. To achieve this optimal design, the article conducts a thorough energy-exergy-economic-environment (4E) analysis of the system and employs the non-dominated sorting genetic algorithm (NSGA II) for the optimizations. A benchmarking analysis is also conducted to show the importance of industrial heat supply in this cycle. The results show that this hybridization, owing to the cheap and flexible heat delivery of the waste incinerator as well as the low cost of the solar collectors, is very effective for efficient and cheap multi-generation. Especially for industrial heat supply, the competitive levelized cost of energy (LCOE) of 23.96 €/MWh is obtained, which is way lower than today's achievable costs in the industry.


Subject(s)
Incineration , Solar Energy , Incineration/methods , Hot Temperature , Solid Waste/analysis , Temperature
2.
Micromachines (Basel) ; 14(12)2023 Dec 09.
Article in English | MEDLINE | ID: mdl-38138389

ABSTRACT

Based on three-dimensional optical proximity correction (3D OPC), recent advancements in 3D lithography have enabled the high-fidelity customization of 3D micro-optical elements. However, the micron-to-millimeter-scale structures represented by the Fresnel lens design bring more stringent requirements for 3D OPC, which poses significant challenges to the accuracy of models and the efficiency of algorithms. Thus, a lithographic model based on optical imaging and photochemical reaction curves is developed in this paper, and a subdomain division method with a statistics principle is proposed to improve the efficiency and accuracy of 3D OPC. Both the simulation and the experimental results show the superiority of the proposed 3D OPC method in the fabrication of Fresnel lenses. The computation memory requirements of the 3D OPC are reduced to below 1%, and the profile error of the fabricated Fresnel lens is reduced 79.98%. Applying the Fresnel lenses to an imaging system, the average peak signal to noise ratio (PSNR) of the image is increased by 18.92%, and the average contrast of the image is enhanced by 36%. We believe that the proposed 3D OPC method can be extended to the fabrication of vision-correcting ophthalmological lenses.

3.
Polymers (Basel) ; 15(16)2023 Aug 14.
Article in English | MEDLINE | ID: mdl-37631460

ABSTRACT

The Fresnel lens is an optical system consisting of a series of concentric diamond grooves. One surface of the lens is smooth, while the other is engraved with concentric circles of increasing size. Optical interference, diffraction, and sensitivity to the angle of incidence are used to design the microstructure on the lens surface. The imaging of the optical surface depends on its curvature. By reducing the thickness of the lens, light can still be focused at the same focal point as with a thicker lens. Previously, lenses, including Fresnel lenses, were made of glass due to material limitations. However, the traditional grinding and polishing methods for making Fresnel lenses were not only time-consuming, but also labour-intensive. As a result, costs were high. Later, a thermal pressing process using metal moulds was invented. However, the high surface tension of glass caused some detailed parts to be deformed during the pressing process, resulting in unsatisfactory Fresnel lens performance. In addition, the complex manufacturing process and unstable processing accuracy hindered mass production. This resulted in high prices and limited applications for Fresnel lenses. These factors prevented the widespread use of early Fresnel lenses. In contrast, polymer materials offer advantages, such as low density, light weight, high strength-to-weight ratios, and corrosion resistance. They are also cost effective and available in a wide range of grades. Polymer materials have gradually replaced optical glass and other materials in the manufacture of micro-optical lenses and other miniaturised devices. Therefore, this study focuses on investigating the manufacturing parameters of Fresnel lenses in the injection moulding process. We compare the quality of products obtained by two-stage injection moulding, injection compression moulding, and IMD (in-mould decoration) techniques. The results show that the optimal method is IMD, which reduces the nodal displacement on the Fresnel lens surface and improves the transmission performance. To achieve this, we first establish a Kriging model to correlate the process parameters with optimisation objectives, mapping the design parameters and optimisation objectives. Based on the Kriging model, we integrate the NSGA-II algorithm with the predictive model to obtain the Pareto optimal solutions. By analysing the Pareto frontier, we identify the best process parameters. Finally, it is determined that the average nodal displacement on the Fresnel surface is 0.393 mm, at a holding pressure of 320.35 MPa and a melt temperature of 251.40 °C. Combined with IMD technology, product testing shows a transmittance of 95.43% and an optimisation rate of 59.64%.

4.
Micromachines (Basel) ; 14(6)2023 May 31.
Article in English | MEDLINE | ID: mdl-37374762

ABSTRACT

Focused ultrasound featuring non-destructive and high sensitivity has attracted widespread attention in biomedical and industrial evaluation. However, most traditional focusing techniques focus on the design and improvement of single-point focusing, neglecting the need to carry more dimensions of multifocal beams. Here we propose an automatic multifocal beamforming method, which is implemented using a four-step phase metasurface. The metasurface composed of four-step phases improves the transmission efficiency of acoustic waves as a matching layer and enhances the focusing efficiency at the target focal position. The change in the number of focused beams does not affect the full width at half maximum (FWHM), revealing the flexibility of the arbitrary multifocal beamforming method. Phase-optimized hybrid lenses reduce the sidelobe amplitude, and excellent agreement is observed between the simulation and experiments for triple-focusing beamforming metasurface lenses. The particle trapping experiment further validates the profile of the triple-focusing beam. The proposed hybrid lens can achieve flexible focusing in three dimensions (3D) and arbitrary multipoint, which may have potential prospects for biomedical imaging, acoustic tweezers, and brain neural modulation.

5.
Ultrasonics ; 131: 106934, 2023 May.
Article in English | MEDLINE | ID: mdl-36773482

ABSTRACT

Two single element, 8 mm focal depth, 6 MHz PZT-5A 40% volume fraction 1-3 composite Fresnel aluminum lens based therapeutic ultrasound transducers for use in small animal histotripsy applications were built with 15 mm outer diameters - one with a central hole of 5.7 mm diameter for future co-registration and one full-aperture. The device was built with the front face filled with acoustically transparent epoxy to create a flat aperture allowing gel-coupling to tissue, where the Fresnel lens design allowed flattening of the aperture with minimal epoxy fill. Epoxy fill resulted in a 6% loss of focal pressure. The full-aperture device achieved 37 MPa/100 V peak-to-peak focal pressures with the removed center element device achieving 25 MPa/100V - a 32% reduction, which matches COMSOL simulated results. Pulsing between 190 V and 270 V at 17 cycles and 1 kHz PRF, the full-aperture device generated bubble clouds in water ranging from 0.31 mm to 0.51 mm radially, and 0.53 mm to 0.81 mm axially. Cavitation for the removed center element device was observed to begin at 370 V, and was consistent at 400 V.

6.
Sensors (Basel) ; 22(21)2022 Nov 07.
Article in English | MEDLINE | ID: mdl-36366271

ABSTRACT

The polymerase chain reaction is an important technique in biological research. However, it is time consuming and has a number of disadvantages. Therefore, real-time PCR technology that can be used in real-time monitoring has emerged, and many studies are being conducted regarding its use. Real-time PCR requires many optical components and imaging devices such as expensive, high-performance cameras. Therefore, its cost and assembly process are limitations to its use. Currently, due to the development of smart camera devices, small, inexpensive cameras and various lenses are being developed. In this paper, we present a Compact Camera Fluorescence Detector for use in parallel-light lens-based real-time PCR devices. The proposed system has a simple optical structure, the system cost can be reduced, and the size can be miniaturized. This system only incorporates Fresnel lenses without additional optics in order for the same field of view to be achieved for 25 tubes. In the center of the Fresnel lens, one LED and a complementary metal-oxide semiconductor camera were placed in directions that were as similar as possible. In addition, to achieve the accurate analysis of the results, image processing was used to correct them. As a result of an experiment using a reference fluorescent substance and double-distilled water, it was confirmed that stable fluorescence detection was possible.


Subject(s)
Lenses , Optical Devices , Real-Time Polymerase Chain Reaction , Optics and Photonics , Image Processing, Computer-Assisted
7.
Biosensors (Basel) ; 12(1)2022 Jan 13.
Article in English | MEDLINE | ID: mdl-35049668

ABSTRACT

Measuring pH has become a major key for determining health conditions, and food safety. The traditional pH assessment approaches are costly and offer low sensitivity. Here, a novel pH sensor based on a pH-responsive hydrogel has been developed. A Fresnel lens pattern was replicated on the surface of the pH-responsive hydrogel using the replica mould method. The pH sensors were tested in a pH range of 4-7. Introducing various pH solutions to the pH sensor led to volumetric shifts as the hydrogel swelled with pH. Consequently, the dimensions of the replicated Fresnel lens changed, modifying the focal length and the focus efficiency of the optical sensor. As a result, the measured optical power at a fixed distance from the sensor changed with pH. The optical sensor showed the best performance in the acidic region when pH changed from 4.5 to 5.5, in which the recorded power increased by 13%. The sensor exhibited high sensitivity to pH changes with a short respond time in a reversible manner. The developed pH optical sensor may have applications in medical point-of-care diagnostics and wearable continuous pH detection devices.


Subject(s)
Hydrogels , Wearable Electronic Devices , Hydrogen-Ion Concentration
8.
Micromachines (Basel) ; 12(11)2021 Oct 26.
Article in English | MEDLINE | ID: mdl-34832726

ABSTRACT

Evolvable acoustic fields are considered an effective method for solving technical problems related to fields such as biological imaging, particle manipulation, drug therapy and intervention. However, because of technical difficulties and the limited technology available for realizing flexible adjustments of sound fields, few studies have reported on this aspect in recent years. Herein, we propose a novel solution, using a Fresnel lens-focused ultrasonic transducer for generating excited-signal-dependent acoustic pressure patterns. Finite element analysis (FEA) is used to predict the performance of a transducer with a Fresnel lens. The Fresnel lens is printed using 3D additive manufacturing. Normalized intensity maps of the acoustic pressure fields are characterized from the Fresnel lens-focused transducer under various numbers of excited-signal cycles. The results demonstrate that under different cycle excitations, a temporal evolution acoustic intensity can be generated and regulated by an ultrasound transducer with a 3D Fresnel lens. This acoustical pattern control method is not only simple to realize but also has considerable application prospects.

9.
Sensors (Basel) ; 21(19)2021 Oct 08.
Article in English | MEDLINE | ID: mdl-34641010

ABSTRACT

This paper presents an experimental setup to measure the horizontal centering error of a pre-built pyroelectric infrared (PIR) sensor module, in which a dual-element PIR sensor is aligned at the focal point of a single-zone Fresnel Lens. In the setup, the sensor module was placed facing a modulated infrared radiating source and turned over a range of horizontal angles. The position of the optical axis of the sensor module was determined based on the analysis of the output response of the sensor at turned angles. Thus, the horizontal centering error of the module is defined as the difference between the mechanical axis of the housing and the found optical axis. For the prebuilt sensor module, with the specific available equipment, the measurement of the centering error of the module achieved a resolution of 0.02 degrees.

10.
Polymers (Basel) ; 12(12)2020 Dec 12.
Article in English | MEDLINE | ID: mdl-33322782

ABSTRACT

This paper presents a focusing efficiency and focal length tunable planar Fresnel lens in reflection type based on azo-dye-doped cholesterol liquid crystal film. The Fresnel-like pattern of a pumping beam can be formed by a Sagnac interferometer. When the azo-dye molecules are irradiated by the pumping beam, the photoalignment effect will be induced in the bright (odd) zones due to the trans-cis photoisomerization of azo-dye molecules. Thus, the structures of cholesteric liquid crystals in the odd zones will reorient from the imperfectly planar textures to the perfectly planar textures. The different structures of cholesteric liquid crystals in two adjacent zones will give rise to phase difference for the reflected light and thus function as a Fresnel lens. The focusing efficiency of the proposed Fresnel lens can be controlled by the applied voltages and affected by the polarization state of incident light. Moreover, various focal lengths of the Fresnel lens can be achieved by rewriting a different center radius of the Fresnel-like pattern.

11.
Micromachines (Basel) ; 11(2)2020 Jan 21.
Article in English | MEDLINE | ID: mdl-31972956

ABSTRACT

Femtosecond laser direct writing through two-photon polymerization has been widely used in precision fabrication of three-dimensional microstructures but is usually time consuming. In this article, we report the rapid fabrication of continuous surface Fresnel lens array through femtosecond laser three-dimensional focal field engineering. Each Fresnel lens is formed by continuous two-photon polymerization of the two-dimensional slices of the whole structure with one-dimensional scan of the corresponding two-dimensional engineered intensity distribution. Moreover, we anneal the lens array to improve its focusing and imaging performance.

12.
J Microelectromech Syst ; 29(5): 692-698, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33746473

ABSTRACT

This paper describes a novel acoustic transducer with dual functionality based on 1-mm-thick lead zirconate titanate (PZT) substrate with a modified air-cavity Fresnel acoustic lens on top. Designed to let ultrasound waves focus over an annular ring region, the lens generates a long depth-of-focus Bessel-like focal beam and multiple trapping zones based on quasi-Airy beams and bottle beams. With 2.32 MHz sinusoidal driving signal at 150 Vpp, the transducer produces a focal zone with 9.9 mm depth-of-focus and 0.8 MPa peak pressure at a focal length of 31.33 mm. With 2.32 MHz continuous sinusoidal drive at 30-35 Vpp, the transducer is able to trap multiple polyethylene microspheres (350-1,000 µm in diameter and 1.025-1.130 g/cm3 in density) in water either simultaneously (when suspended by mechanical agitation or released from water surface) or sequentially (when placed one after another with a pipette). The largest particles the transducer could trap are two 1-mm-diameter microspheres stuck together (1.07 mg in weight, lifted by buoyance and 0.257 µN acoustic-field-induced force). When the transducer is moved laterally, some firmly trapped microspheres follow along the transducer's movement, while being trapped. When trapped, some microspheres can rotate due to the rotation torque generated by the quasi-Airy beams.

13.
Polymers (Basel) ; 11(9)2019 Sep 04.
Article in English | MEDLINE | ID: mdl-31487836

ABSTRACT

This paper presents an electrically tunable Fresnel lens in a twisted nematic liquid crystal cell fabricated by using a Sagnac interferometer. When the Fresnel-patterned green beam, formed by the Sagnac interferometer, is irradiated on the azo-dye doped liquid crystal mixture, the azo-dye molecules undergo trans-cis photoisomerization and then generate the photo-alignment effect in the bright (odd) zones. The director of the liquid crystal molecules in the odd zones reorients the direction perpendicular to the polarization direction of the linearly polarized green beam. The various structures of liquid crystals in the odd and even zones will result in a phase difference and thus, a Fresnel lens can be generated. The experimental results show that the proposed Fresnel lens has a high diffraction efficiency of 31.5% under an applied alternating-currents (AC) voltage. The focal length of the Fresnel lens can also be tuned by thermally erasing the photo-alignment effect of the azo dyes and rewriting by a different Fresnel-like pattern.

14.
Sensors (Basel) ; 19(16)2019 Aug 18.
Article in English | MEDLINE | ID: mdl-31426566

ABSTRACT

Chromatic confocal technology (CCT) is one of the most promising methods for the contactless and accurate measurement of structure profiles. Based on the principles of chromatic dispersion and confocal theory, a dispersion probe is proposed and optimized with several commercial and cheap refractive index lenses. The probe provides 0.3× magnification and a dispersion range of 400 µm with a commercial LED source with an effective bandwidth of ca. 450-623 nm. Since the noise fluctuation can affect the extraction stability of the focal wavelength, a modification to the centroid peak extraction algorithm is proposed in this paper, where several virtual pixels are interpolated among the real pixels of the spectrometer before thresholding. In addition, a series of experiments were carried out to test the system's displacement measurement performance. The results clearly show that stability is improved by the modified algorithm, and the calibration repeatability is ±0.3 µm in the full measurement range with a linear stage. The standard deviation at the fixed position has an optimal value of 0.009 µm. The section profile of a Fresnel lens is measured by the CCT system to demonstrate its high feasibility and efficiency.

15.
ACS Appl Mater Interfaces ; 10(1): 1217-1224, 2018 Jan 10.
Article in English | MEDLINE | ID: mdl-29235344

ABSTRACT

Holographic photopolymers capable of high refractive index modulation (Δn) on the order of 10-2 are integral for the fabrication of functional holographic optical elements that are useful in a myriad of optical applications. In particular, to address the deficiency of suitable high refractive index writing monomers for use in two-stage holographic formulations, here we report a novel high refractive index writing monomer, 1,3-bis(phenylthio)-2-propyl acrylate (BPTPA), simultaneously possessing enhanced solubility in a low refractive index (n = 1.47) urethane matrix. When examined in comparison to a widely used high refractive index monomer, 2,4,6-tribromophenyl acrylate, BPTPA exhibited superior solubility in a stage 1 urethane matrix of approximately 50% with a 20% higher refractive index increase per unit amount of the writing monomer for stage 2 polymerizations. Formulations with 60 wt % loading of BPTPA exhibit a peak-to-mean holographic Δn ≈ 0.029 without obvious deficiencies in transparency, color, or scatter. To the best of our knowledge, this value is the highest reported in the peer-reviewed literature for a transmission hologram. The capabilities and versatility of BPTPA-based formulations are demonstrated at varying length scales via demonstrative refractive index gradient structure examples including direct laser write, projection mask lithography of a 1″ diameter Fresnel lens, and ∼100% diffraction efficiency volume transmission holograms with a 1 µm fringe spacing in 11 µm thick samples.

16.
Sensors (Basel) ; 17(12)2017 Dec 05.
Article in English | MEDLINE | ID: mdl-29206137

ABSTRACT

The focusing properties of Fresnel Zone Plates (FZPs) against frequency are analyzed in this work. It is shown that the FZP focal length depends almost linearly on the operating frequency. Focal depth and focal distortion are also considered, establishing a limit on the frequency span at which the operating frequency can be shifted. An underwater FZP ultrasound focusing system is demonstrated, and experimental results agree with the theoretical analysis and simulations.

17.
Sensors (Basel) ; 17(7)2017 Jul 22.
Article in English | MEDLINE | ID: mdl-28737674

ABSTRACT

The focusing capabilities of a pinhole zone plate lens are presented and compared with those of a conventional Fresnel zone plate lens. The focusing properties are examined both experimentally and numerically. The results confirm that a pinhole zone plate lens can be an alternative to a Fresnel lens. A smooth filtering effect is created in pinhole zone plate lenses, giving rise to a reduction of the side lobes around the principal focus associated with the conventional Fresnel zone plate lens. The manufacturing technique of the pinhole zone plate lens allows the designing and constructing of lenses for different focal lengths quickly and economically and without the need to drill new plates.

18.
Sensors (Basel) ; 16(11)2016 Nov 23.
Article in English | MEDLINE | ID: mdl-27886050

ABSTRACT

In this paper, acoustic tweezers which use beam forming performed by a Fresnel zone plate are proposed. The performance has been demonstrated by finite element analysis, including the acoustic intensity, acoustic pressure, acoustic potential energy, gradient force, and particle distribution. The acoustic tweezers use an ultrasound beam produced by a lead zirconate titanate (PZT) transducer operating at 2.4 MHz and 100 Vpeak-to-peak in a water medium. The design of the Fresnel lens (zone plate) is based on air reflection, acoustic impedance matching, and the Fresnel half-wave band (FHWB) theory. This acoustic Fresnel lens can produce gradient force and acoustic potential wells that allow the capture and manipulation of single particles or clusters of particles. Simulation results strongly indicate a good trapping ability, for particles under 150 µm in diameter, in the minimum energy location. This can be useful for cell or microorganism manipulation.

19.
ACS Appl Mater Interfaces ; 7(16): 8809-16, 2015 Apr 29.
Article in English | MEDLINE | ID: mdl-25853731

ABSTRACT

Silk proteins from spiders and silkworms have been proposed as outstanding candidates for soft micro-optic and photonic applications because of their optical transparency, unique biological properties, and mechanical robustness. Here, we present a method to form microstructures of the two constituent silk proteins, fibroin and sericin for use as an optical biomaterial. Using photolithography, chemically modified silk protein photoresists are patterned in 2D arrays of periodic patterns and Fresnel zone plates. Angle-dependent iridescent colors are produced in these periodic micropatterns because of the Bragg diffraction. Silk protein photolithography can used to form patterns on different substrates including flexible sheets with features of any shape with high fidelity and resolution over large areas. Finally, we show that these mechanically stable and transparent iridescent architectures are also completely biodegradable. This versatile and scalable technique can therefore be used to develop biocompatible, soft micro-optic devices that can be degraded in a controlled manner.


Subject(s)
Biocompatible Materials/chemistry , Fibroins/chemistry , Optics and Photonics/methods , Sericins/chemistry , Animals , Bombyx , Fibroins/ultrastructure , Luminescence , Materials Testing , Microscopy, Atomic Force , Optical Imaging , Proteolysis , Sericins/ultrastructure
20.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-74934

ABSTRACT

PURPOSE: To compare electroretinogram (ERG) waveforms acquired using a ganzfeld stimulator and a Fresnel ganzfeld stimulator. METHODS: ERGs were recorded with a ganzfeld stimulator and a Fresnel ganzfeld stimulator from both eyes of 25 volunteers. Peak-to-trough amplitudes and peak implicit times were compared between both eyes and between a ganzfeld stimulator and a Fresnel ganzfeld stimulator. ERGs taken from the sitting and supine positions were also compared using the Fresnel ganzfeld stimulator. RESULTS: There was no statistically significant difference between the Fresnel ganzfeld stimulator and dome-shaped ganzfeld stimulator in amplitude and implicit time of dark adapted 0.01, 3.0 ERG, photopic 3.0 ERG, photopic 3.0 flicker. The differences in amplitude and implicit time between the right and left eyes were not influenced by the Fresnel ganzfeld stimulator. Additionally, no differences were observed in ERGs obtained from the sitting and supine positions using the Fresnel ganzfeld stimulator. CONCLUSIONS: The newly developed ganzfeld stimulator with a sealed Fresnel lens can be considered as a reliable alternative method for measuring ERGs. Fresnel ganzfeld stimulator is useful for patients having problems with mobility or uncooperative children.


Subject(s)
Child , Humans , Supine Position , Volunteers
SELECTION OF CITATIONS
SEARCH DETAIL
...