1.
Sensors (Basel) ; 22(5)2022 Feb 27.
Article in English | MEDLINE | ID: mdl-35271021

ABSTRACT

This paper presents the process of designing, fabricating, assembling, programming and optimizing a prototype nonlinear mechatronic Ball-Plate System (BPS) as a laboratory platform for engineering education STEM. Due to the nonlinearity and complexity of BPS, the task presents challenges such as: (1) difficulty in controlling the stabilization of a particular position point, known as steady-state error, (2) position resolution, known as specific distance error, and (3) adverse environmental effects-light-shadow error, which is also discussed in this paper. The laboratory prototype BPS for education was designed, manufactured and installed at Karlovac University of Applied Sciences in the Department of Mechanical Engineering, Mechatronics program. The low-cost two-degree BPS uses a USB HD camera for computer vision as a feedback sensor and two DC servo motors as actuators. Due to control problems, an advanced block diagram of the control system is proposed and discussed. An open-source control system based on Python scripts, which allows the use of ready-made functions from the library, allows the color of the ball and the parameters of the PID controller to be changed, indirectly simplifying the control system and performing mathematical calculations directly. The authors will continue their research on this BPS mechatronic platform and control algorithms.


Subject(s)
Algorithms , Computers , Feedback
2.
Sensors (Basel) ; 18(2)2018 Feb 08.
Article in English | MEDLINE | ID: mdl-29419782

ABSTRACT

In this work, we irradiated a high-definition (HD) industrial camera based on a commercial-off-the-shelf (COTS) CMOS image sensor (CIS) with Cobalt-60 gamma-rays. All components of the camera under test were fabricated without radiation hardening, except for the lens. The irradiation experiments of the HD camera under biased conditions were carried out at 1.0, 10.0, 20.0, 50.0 and 100.0 Gy/h. During the experiment, we found that the tested camera showed a remarkable degradation after irradiation and differed in the dose rates. With the increase of dose rate, the same target images become brighter. Under the same dose rate, the radiation effect in bright area is lower than that in dark area. Under different dose rates, the higher the dose rate is, the worse the radiation effect will be in both bright and dark areas. And the standard deviations of bright and dark areas become greater. Furthermore, through the progressive degradation analysis of the captured image, experimental results demonstrate that the attenuation of signal to noise ratio (SNR) versus radiation time is not obvious at the same dose rate, and the degradation is more and more serious with increasing dose rate. Additionally, the decrease rate of SNR at 20.0, 50.0 and 100.0 Gy/h is far greater than that at 1.0 and 10.0 Gy/h. Even so, we confirm that the HD industrial camera is still working at 10.0 Gy/h during the 8 h of measurements, with a moderate decrease of the SNR (5 dB). The work is valuable and can provide suggestion for camera users in the radiation field.

3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-509915

ABSTRACT

Objective To explore the application and implementation of narrow band imaging (NBI) in fiberscope.Methods NBI color filter in the light source gifted the host machine with NBI function,and the application of DBI technique in fiberscope was implemented with a compatible HD camera.Results NBI technique involved in fiberscope decreased the costs in hospital and departments,relieved patient pain and increased the diagnosis rate.Conclusion NBI technique can be applied to electron mirror and fiberscope,and gains advantages in the future.