Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-430134

ABSTRACT

Objective To evaluate the efficacy of laparoscopic Habib 4X (Habib 4X,Angio Dynamics US),a new bipolar radiofrequency (RF) device,in laparoscopic liver resection.Methods Thirty one patients who underwent laparoscopic liver resection using the laparoscopic Habib 4X from Sept 2009 to Apr 2012 were studied retrospectively.Results The laparoscopic Habib 4X was success fully used in 30 patients (malignant,n=18; benign,n=12).The procedures performed included left lateral sectionectomy (n=12),left hemi-hepatectomy (n=1),Ⅴ or Ⅵ segmentectomy (n=9),Ⅴ and Ⅵ bi-segmentectomy (n=2) and wedge exclusion (n=6).The time required for precoagulation and resection was 10~68 min (median 24 min).The mean intraoperative blood loss was 145±75ml (range 8-370 ml).Mild abnormal liver function which returned to normal in 3 to 5 days was detected postoperatively.The mean hospital stay was 7.8±2.6 d (range 3~12 days).There was no patient who developed postoperative bleeding,bile leakage or abdominal abscess.For cancer patients,there was no local recurrence on follow-up.Conclusion Laparoscopic Habib 4X,a device when used in laparoscopic liver resection,resulted in minimal blood loss and quick recovery.It had only mild effect on liver function and it had low morbidity.In addition,it might reduce the risk of local recurrence in malignant tumours.

2.
HPB (Oxford) ; 10(4): 261-4, 2008.
Article in English | MEDLINE | ID: mdl-18773100

ABSTRACT

BACKGROUND: In recent years the progress of laparoscopic procedures and the development of new and dedicated technologies have made laparoscopic hepatic surgery feasible and safe. In spite of this laparoscopic liver resection remains a surgical procedure of great challenge because of the risk of massive bleeding during liver transection and the complicated biliary and vascular anatomy in the liver. A new laparoscopic device is reported here to assist liver resection laparoscopically. METHODS: The laparoscopic Habib 4X is a bipolar radiofrequency device consisting of a 2 x 2 array of needles arranged in a rectangle. It is introduced perpendicularly into the liver, along the intended transection line. It produces coagulative necrosis of the liver parenchyma sealing biliary radicals and blood vessels and enables bloodless transection of the liver parenchyma. RESULTS: Twenty-four Laparoscopic liver resections were performed with LH4X out of a total of 28 attempted resections over 12 months. Pringle manoeuvre was not used in any of the patients. None of the patients required intraoperative transfusion of red cells or blood products. CONCLUSION: Laparoscopic liver resection can be safely performed with laparoscopic Habib 4X with a significantly low risk of intraoperative bleeding or postoperative complications.

3.
HPB (Oxford) ; 10(4): 256-60, 2008.
Article in English | MEDLINE | ID: mdl-18773112

ABSTRACT

BACKGROUND: Intraoperative blood loss has been shown to be an important factor correlating with morbidity and mortality in liver surgery. In spite of the technological advances in hepatic parenchymal transection devices, bleeding remains the single most important complication of liver surgery. The role of radiofrequency (RF) in liver surgery has been expanded from tumour ablation to major hepatic resections in the last decade. Habib 4X, a new bipolar RF device designed specifically for liver resection is described here. METHODS: Habib 4X is a bipolar, handheld, disposable RF device and consists of two pairs of opposing electrodes which is introduced perpendicularly into the liver, along the intended transection line. It produces controlled RF energy between the electrodes and the heat produced seals even major biliary and blood vessels and enables resection of the liver parenchyma with a scalpel without blood loss or biliary leak. RESULTS: Three hundred and eleven patients underwent 384 liver resections from January 2002 to October 2007 with this device. There were 109 major resections and none of the patients had vascular inflow occlusion (Pringle's manoeuvre). Mean intraoperative blood loss was 305 ml (range 0-4300) ml, with less than 5% (n=18) rate of transfusion. CONCLUSION: Habib 4X is an additional device for hepatobiliary surgeons to perform liver resections with minimal blood loss and low morbidity and mortality rates.

SELECTION OF CITATIONS
SEARCH DETAIL
...