Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
Int J Surg Case Rep ; 115: 109123, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38271866

ABSTRACT

INTRODUCTION AND IMPORTANCE: The elbow is one of the most mobile joints, and its movement is very important. Bony ankylosed elbow is an uncommon condition leading to complete loss of activity of elbow, and then lead to severe disability and limitation in activities of daily living. CASE PRESENTATION: A 63-year-old woman sustained comminuted fracture of left distal humerus. She underwent open reduction and internal fixation by plates. After the plates were removed in 2016,stiffness developed.The elbow was stable but fixed at 90°ï¼Œthere was no vascular injury or deficit in sensory and motor function of the ulnar nerve. She hopes to eliminate pain and restore normal mobility compatible with ADL. CLINICAL DISCUSSION: Complete bony ankylosis of the elbow joint may be caused by trauma, rheumatic disease, burns, congenital stiffness and other conditions. Even with the compensation of shoulder and wrist, it will still have a great impact on upper limb function. Whether to treat mainly depends on whether the patient has the require to improve the functionality and return to daily activities. Treatment methods are very limited, including interposition arthroplasty and TEA. Defect of soft tissue appeared was seen in our case, Hernia Patch was innovatively applied to reconstruct the defect of soft tissue and maintain continuity of elbow extension mechanism. CONCLUSION: Patients with post-traumatic elbow joint ankylosis were suffered from severe bony abnormalities, but also soft tissue contracture or defects due to multiple operations and trauma. We present a case of complete bony ankylosed elbow treated with total elbow arthroplasty and Hernia Patch.

2.
J Abdom Wall Surg ; 2: 11499, 2023.
Article in English | MEDLINE | ID: mdl-38312418

ABSTRACT

Background: Hernia patches for umbilical hernia repair have gained popularity due to their short operation time and ease of use. However, up to 10% re-operation and 8% recurrence rates at 2-year follow-up have been published. This retrospective cohort study presents the long-term results of the hernia patch technique for umbilical hernia repair. Methods: All adult patients who underwent a primary umbilical hernia repair at Oulu University Hospital hernia surgery units during 2014-2018 were included in the study. The primary outcome measure was recurrence rate. Secondary outcomes were complications and re-operation rate. Results: A total of 619 elective primary umbilical hernia repairs were performed during 2014-2018. The major technique used was Ventralex™ ST hernia patch repair (79.0%, 488/619) for small hernias with a mean width of 1.8 (SD 0.79) cm. Most of the patches (84.7%, 414/488) were placed in the preperitoneal space. Hernia recurrence rate of patient operated on using Ventralex™ ST hernia patch was 2.5% (12/488) during a mean follow-up time of 68 (SD 16, 43-98) months. Re-operation rate for another reason than recurrence was 1.6% (8/488). Clavien-Dindo complications ≥3 occurred in 4.1% (20/488) of cases and surgical site infection rate was 3.3% (16/488). Conclusion: Umbilical hernia repair using a Ventralex™ ST hernia patch placed in preperitoneal space have acceptable results in terms of recurrence and re-operations in this cohort study.

3.
Biomater Sci ; 1(11)2013 Nov 01.
Article in English | MEDLINE | ID: mdl-24349707

ABSTRACT

Through the use of mechanical reinforcement of collagen matrices, mechanically strong and compliant 3D tissue mimetic scaffolds can be generated that act as scaffolds for soft tissue engineering. Collagen has been widely used for the development of materials for repair, augmentation or replacement of damaged or diseased tissue. Herein we describe a facile method for the layer-by-layer fabrication of robust planar collagen fiber constructs. Collagen gels cast in a phosphate buffer were dried to form dense collagen mats. Subsequent gels were layered and dried atop mats to create multilayer constructs possessing a range of tunable strengths (0.5 - 11 MPa) and stiffness (1 - 115 MPa). Depending on processing conditions and crosslinking of constructs, strain to failure ranged between 9 to 48%. Collagen mats were constructed into hernia patches that prevented hernia recurrence in Wistar rats.

4.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-565581

ABSTRACT

Objective To discuss the operation style of filling,film-style,three-dimensional double-layer mesh tension-free for hernia and the repair materials,the selectlon of surgical operation style for reducing recurrence.Methods We used the style of plug-and-chip,two-dimensional mesh tension-free hernia repair for the treatment of 130 cases of inguinal hernia patients.Results In 130 cases of patients with 1~5 years of follow-up,there was no recurrence.Conclusion A reasonable choice of repair materials and improving the surgical operation can be effective in reducing recurrence.

SELECTION OF CITATIONS
SEARCH DETAIL
...