Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Article in English | MEDLINE | ID: mdl-38987502

ABSTRACT

INTRODUCTION: This study aimed to compare the impact of different broach surface designs on post-operative clinical outcomes, bone reactions and changes in bone mineral density (BMD) in patients who underwent total hip arthroplasty (THA) using a fully hydroxyapatite coated and double tapered stem with either compaction shape (COM) or hybrid shape (HYB) broaches. MATERIALS AND METHODS: A retrospective analysis was conducted on 76 patients (100 hips) who underwent primary THA using the Avenir complete stem®. Patients were divided into two groups: the COM broach group (50 hips) and HYB broach group (50 hips). We evaluated clinical outcomes using the Japanese Orthopaedic Association hip scores one month before the surgery, and 12 and 24 months after the surgery. Radiographic findings, including stem alignment angles, radiolucent lines, spot welds, and cortical hypertrophy, were assessed. BMD around the stem in Gruen zones 1-7 was evaluated using dual-energy X-ray absorptiometry (DEXA) at 7 days, 12, and 24 months post-operatively. The Dorr classification was used to assess femoral morphology. RESULTS: There were no significant differences in clinical outcomes, radiographic findings, or BMD changes between the COM and HYB broach groups in the overall patient cohort. However, in Dorr type A femurs, the COM broach group demonstrated superior BMD superior preservation in zones 1 and 7 after 12 months and in zones 1, 6 and 7 after 24 months. Additionally, in Dorr type B femurs, significant BMD preservation was observed in zone 3 at 24 months in the COM broach group. CONCLUSIONS: This study suggests that the broach surface design of fully hydroxyapatite coated stems may influence periprosthetic BMD changes, especially in Dorr type A and B femurs. Surgeons should consider broach selection based on patient-specific femoral morphology to optimize BMD preservation in THA procedures using fully hydroxyapatite coated stems.

2.
Arch Orthop Trauma Surg ; 144(6): 2881-2887, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38771361

ABSTRACT

INTRODUCTION: Bone maintenance after total hip arthroplasty (THA) is important for implant success. This study aimed to investigate the relationship between patient characteristics and periprosthetic bone maintenance after THA for better implant selection. MATERIALS AND METHODS: This retrospective cohort study enrolled 112 consecutive patients who underwent THA using full hydroxyapatite (HA) compaction with short (n = 55) or short-tapered wedge (n = 61) stems. Periprosthetic bone mineral density (BMD) was compared between the two groups after propensity score matching, and the relationship between periprosthetic BMD changes and patient background was analyzed. RESULTS: Both groups showed similar periprosthetic BMD changes after adjusting for patient background using propensity score matching. Canal flare index > 3.7 in patients that underwent THA using tapered-wedge stem (odds ratio (OR), 3.2; 95% confidence interval (CI), 1.3-7.9, p = 0.013) and baseline zone 1 BMD > 0.65 in patients that received with short HA compaction stems (OR, 430.0; 95% CI 1.3-1420, p = 0.040) were associated with proximal periprosthetic bone maintenance after THA. CONCLUSION: Considering their predictive value, canal flare index and zone 1 BMD assessment might be useful strategies for implant selection during THA.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Density , Femur , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/methods , Retrospective Studies , Male , Female , Middle Aged , Aged , Femur/surgery , Prosthesis Design
3.
Eur J Orthop Surg Traumatol ; 34(4): 2041-2047, 2024 May.
Article in English | MEDLINE | ID: mdl-38517525

ABSTRACT

PURPOSE: This study aimed to compare bone mineral density (BMD) changes around the femoral component after total hip arthroplasty (THA) in a fully hydroxyapatite-coated stem (CORAIL) and in a tapered-wedge stem (Taperloc complete) and identify predictors of BMD changes. METHODS: This retrospective study compared 43 hips in the CORAIL group and 40 hips in the Taperloc group. The relative changes in BMD at 2 years after THA measured using dual-energy X-ray absorptiometry and the three-dimensional quantified contact states of the stem with the femoral cortical bone were assessed. Predictors of the relative change in the BMD around the proximal part of the stem were examined using multiple regression analysis. RESULTS: The decrease in BMD in Gruen zone 7 was significantly less in the CORAIL group than in the Taperloc group (P = 0.02). In the CORAIL group, the contact area in any zone was not a significant predictor of the relative changes in BMD. The contact area between the Taperloc stem and the femoral cortical bone in zones 2 and 6 was a positive predictor of the relative changes in BMD in zones 1 (P = 0.02 and P = 0.04, respectively) and 2 (P = 0.008 and P = 0.004, respectively). CONCLUSION: The CORAIL stem suppressed the postoperative BMD loss around the stem, irrespective of the contact state. The Taperloc complete stem required contact with the proximal femoral metaphysis to suppress the postoperative BMD loss around the stem.


Subject(s)
Absorptiometry, Photon , Arthroplasty, Replacement, Hip , Bone Density , Bone Remodeling , Durapatite , Femur , Hip Prosthesis , Prosthesis Design , Humans , Male , Female , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Retrospective Studies , Bone Remodeling/physiology , Middle Aged , Aged , Femur/surgery , Femur/diagnostic imaging , Coated Materials, Biocompatible
4.
J Arthroplasty ; 39(8): 2082-2087, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38360279

ABSTRACT

BACKGROUND: Hydroxyapatite-coated, triple-tapered, shorter-length stems with a medial collar have been reported with good results for a few years. We investigated whether contact between the medial collar and femoral neck affects clinical outcomes and changes in bone mineral density (BMD) in patients who have this type of stem in their total hip arthroplasty construct. METHODS: This was a retrospective, single-center study involving 62 patients scheduled for unilateral total hip arthroplasty using a hydroxyapatite-coated, triple-tapered, shorter-length stem who were followed for at least 1 year postoperatively. All patients had a Dorr type B femoral canal shape. Contact between the medial collar and the femoral neck was evaluated by computed tomography at the third postoperative month, and patients were classified into 2 groups. Postoperative clinical outcomes were investigated by the Western Ontario and McMaster Universities Arthritis Index and the Japanese Orthopaedic Association scores; radiological evaluation included stem fixation, spot welds and cortical hypertrophy, postoperative 3-dimensional stem alignment, and periprosthetic BMD changes. RESULTS: There were 51 patients in the Contact + group (collar and neck contact) and 11 in the Contact-group (no contact). There were no differences between the 2 groups in the improvement of Western Ontario and McMaster Universities Arthritis Index and Japanese Orthopaedic Association scores, stem fixation, occurrence of cortical hypertrophy, or 3-dimensional stem alignment. Radiolucent lines were present in zones 3, 4, and 5 in 6 patients (12%) in the Contact + group only, who had no statistical difference between the 2 groups. Bone mineral density (BMD) decreased most in zone 7 in both groups, with no difference between the 2 groups. CONCLUSIONS: The presence or absence of contact between the medial collar and femoral neck did not affect postoperative BMD changes or radiological or clinical results. LEVEL OF EVIDENCE: Therapeutic Level III.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Density , Durapatite , Femur Neck , Hip Prosthesis , Prosthesis Design , Humans , Male , Female , Retrospective Studies , Arthroplasty, Replacement, Hip/instrumentation , Middle Aged , Aged , Femur Neck/diagnostic imaging , Tomography, X-Ray Computed , Treatment Outcome , Coated Materials, Biocompatible
5.
World Neurosurg ; 184: e367-e373, 2024 04.
Article in English | MEDLINE | ID: mdl-38307197

ABSTRACT

OBJECTIVE: This is a single-surgeon series that prospectively evaluates the results of sacroiliac joint (SIJ) fusion for patients with SIJ dysfunction using hydroxyapatite-coated screws (HACSs) compared with titanium triangular dowels (TTDs). METHODS: A total of 113 patients underwent SIJ fusion surgery between 2013 and 2018 at the University Hospital Llandough to treat symptomatic SIJ dysfunction not responding to nonoperative measures. Of the 113 patients, 40 were treated with HACSs and 73 with TTDs. Patient-reported outcomes measures (PROMs) were collected preoperatively and at 12 months postoperatively, including the 36-item short-form health survey, Oswestry disability index, EuroQol-5D-5L, and Majeed pelvic score. Patients with ongoing symptoms were followed up beyond the study period. RESULTS: Of the 113 patients, 33 completed follow-up in the HACS group compared with 61 in the TTD group. Both groups had comparable preoperative PROMs; however, the postoperative PROMs were significantly better in the TTD group. Additionally, 21 patients (63%) in the HACS group had radiological evidence of screw lysis compared with 5 patients (9%) in the TTD group. A subgroup analysis revealed less significant improvement in PROMs for patients with screw lysis compared with those without. Four patients were offered further revision surgery. CONCLUSIONS: Minimally invasive SIJ fusion has been shown to have good clinical outcomes for select patients. However, our experience shows that HACSs are associated with a high rate of screw lysis and poorer patient outcomes compared with TTDs. Therefore, we recommend the use of TTDs instead of HACSs for SIJ fusion surgery.


Subject(s)
Spinal Diseases , Spinal Fusion , Humans , Titanium , Spinal Fusion/methods , Sacroiliac Joint/surgery , Prospective Studies , Durapatite/therapeutic use , Minimally Invasive Surgical Procedures/methods , Spinal Diseases/surgery , Outcome Assessment, Health Care
6.
Chemosphere ; 342: 140161, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37716566

ABSTRACT

Fluoride (F) contamination in groundwater affects millions of people across the world. Although several sorbents have been identified for low-cost F removal, the choice of the optimal sorbent is dictated by the specific chemistry of contaminated groundwater. In this contribution, eight prevalent sorbents-activated alumina (AA), calcite, hydroxyapatite-coated calcite (HCC), natural chitosan, chalk, Mg-Al-CO3 layered double hydroxide (LDH), calcined Mg-Al-CO3 LDH (cLDH), and hydrous ferric oxide (HFO)-were categorized on their relative F removal mechanisms, extents, and kinetics from a typical synthetic groundwater, representative of contaminated aquifers of North India. Initially, batch experiments containing sorbents at 4 g·L-1 were conducted at a high F concentration (2.9 mM). The dominant F removal processes were identified by aqueous- and solid-phase characterization of reaction by-products. While chalk and calcite removed F by secondary precipitation of fluorite, HCC removed F by fluorapatite precipitation, and other sorbents removed F by sorption. Depending on the immobilization mechanism identified, the F uptake kinetics on each sorbent was modeled with either pseudo-second order or generalized rate equations. Among sorptive F uptake, cLDH exhibited the highest (10-2.15 mg·g-1·h-1) and HFO showed the lowest (10-4.15 mg·g-1·h-1) rates. Fluoride removal by precipitation was the fastest with chalk at 10-1.3 (h-1) (0.16). Subsequent experiments with AA and HCC at lower initial F concentration (0.42 mM) suggested increased uptake by ∼30x and ∼7x, respectively, relative to uptake in 2.9 mM initial F systems. For AA, apart from the widely-accepted mechanism of adsorption, an unidentified F-containing surface precipitate was formed. HCC was identified as the most promising sorbent with no sludge generation.

7.
Arch Orthop Trauma Surg ; 143(7): 4465-4472, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36261646

ABSTRACT

INTRODUCTION: It is clinically important to analyze the initial contact state between an implant and femoral cortical bone as it affects clinical outcomes, such as stress shielding, stem subsidence, thigh pain, and patient-reported outcomes after total hip arthroplasty. Whether the initial contact state of a double-tapered fully hydroxyapatite (HA)-coated stem is achieved with the preserved cancellous or cortical bone remains to be established. This study aimed to compare the contact area with the femoral cortical bone between a double-tapered fully HA-coated stem (HA group) and a tapered wedge cementless stem (TW group) using three-dimensional computed tomography (3DCT)-based templating software. MATERIALS AND METHODS: Forty-seven total hip arthroplasties in the HA and TW groups each were retrospectively analyzed. The contact area between the implant and femoral cortical bone in the whole stem and at each Gruen zone was measured using density mapping with 3DCT-based templating software. RESULTS: The demographic data were not significantly different between the two groups. The contact area in the whole stem area was lower in the HA group (HA 5.4 ± 1.8% vs. TW 9.0 ± 4.8%, p < 0.01). The HA group had a lower contact area in zone 2 (HA 6.7 ± 6.5% vs. TW 15.6 ± 10.8%, p < 0.01) and zone 6 (HA 1.8 ± 3.5% vs. TW 6.3 ± 3.6%, p < 0.01) than the TW group. The implant type (ß = 0.41, p < 0.01) and stem coronal alignment (ß = - 0.29, p < 0.01) were significant predictors of the contact area in the whole stem area in a multiple regression analysis (adjusted R2 = 0.27, p < 0.01). CONCLUSION: The contact area of the double-tapered fully HA-coated stem was significantly lower than that of the tapered wedge cementless stem.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Durapatite , Retrospective Studies , Arthroplasty, Replacement, Hip/methods , Tomography, X-Ray Computed/methods , Femur/diagnostic imaging , Femur/surgery , Cortical Bone/diagnostic imaging , Cortical Bone/surgery , Prosthesis Design
8.
J Orthop Surg Res ; 17(1): 131, 2022 Mar 03.
Article in English | MEDLINE | ID: mdl-35241103

ABSTRACT

BACKGROUND: To improve implant survival through accelerated early bone remodeling during total hip arthroplasty (THA), hydroxyapatite (HA) is widely used as a bioactive coating, which is believed to enhance initial fixation by osseointegration. We aimed to investigate the relationship between stem insertion alignment and postoperative bone mineral density (BMD) changes in patients with full hydroxyapatite-coated (HA) compaction short stem and short tapered-wedge stem. METHODS: This retrospective cohort study enrolled 115 consecutive patients (115 joints) undergoing THA using the full HA compaction short (n = 59) and short tapered-wedge (n = 56) stems. Stem alignment, including anteversion, valgus, and anterior tilt were measured by a three-dimensional template using computed tomography data. Post-operative peri-prosthetic BMD was measured by dual-energy X-ray absorptiometry. The relationship between stem alignment and BMD changes in the stems was analyzed. RESULTS: Patterns of peri-prosthetic BMD changes were similar in both groups. Stem insertion alignments of anteversion, valgus, and anterior tilt were different between the two stem types. Stem alignment of valgus and anterior tilt did not affect peri-prosthetic BMD in either of the stem type. An absolute anteversion difference between stem anteversion and original canal anteversion caused significant peri-prosthetic BMD loss in Gruen zones one and seven in the tapered-wedge stem. However, stem alignment of absolute anteversion difference did not affect BMD changes in the HA compaction stem. CONCLUSIONS: Peri-prosthetic bone remodeling remained unaffected by stem alignment after THA with the new short full HA compaction stem.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Bone Remodeling , Durapatite , Hip Prosthesis , Prosthesis Design , Absorptiometry, Photon/methods , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Bone Density , Female , Femur , Humans , Male , Middle Aged , Retrospective Studies
9.
Arch Orthop Trauma Surg ; 142(10): 2903-2910, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34435238

ABSTRACT

PURPOSE: We aimed to investigate the differences in peri-prosthetic bone remodelling between the full hydroxyapatite (HA)-collared compaction short stem and the short tapered-wedge stem. METHODS: This retrospective cohort study enrolled 159 consecutive patients (159 joints) undergoing total hip arthroplasty (THA) using the full HA compaction short (n = 64) and short tapered-wedge (n = 95) stems. Body mass index (BMI), peri-prosthetic bone mineral density (BMD), and clinical factors, including the Japanese Orthopaedic Association score and the University of California Los Angeles (UCLA) activity score were assessed and compared. RESULTS: Stem related complications were seen in three cases. Both groups showed similar peri-prosthetic BMD changes. Peri-prosthetic BMD was almost maintained in the distal femur and Gruen zone 6 with both type of stems, but significant BMD loss was found in zones 1 and 7 in both groups and in zone 2 of the full HA compaction stem group. No significant correlations were found between the proximal femoral BMD changes and the age, BMI, and UCLA score in both the full HA compaction and tapered-wedge stem groups. Femoral bone shape affected the peri-prosthetic BMD changes in the tapered-wedge stem group but not in the full HA compaction group. The stem collar of the full HA compaction stem did not affect peri-prosthetic BMD, but unique bone remodelling in the calcar region was observed in 27.6% cases. A significant difference in the peri-prosthetic BMD changes at Gruen zone 2 was found in patients with or without thigh pain. CONCLUSION: Peri-prosthetic bone remodelling remained unaffected by clinical and radiographic factors after THA with the new short full HA compaction stem. Therefore, this new stem may be useful in a variety of cases.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Absorptiometry, Photon , Bone Density , Bone Remodeling , Durapatite , Femur/surgery , Humans , Prosthesis Design , Retrospective Studies
10.
Surg Neurol Int ; 13: 556, 2022.
Article in English | MEDLINE | ID: mdl-36600749

ABSTRACT

Background: Multiple anterior cervical diskectomy/fusion (ACDF) techniques now use a variety of Polyehteretherketone (PEEK) cages; stand-alone (SA) and zero-profile (ZP) with/without screws, cages filled with demineralized bone matrix/autograft, and cages coated with hydroxyapatite or titanium. We compared the safety/ efficacy between different PEEK ACDF cage constructs in 17 studies, and in some cases, additionally contrasted results with "routine" ACDF (i.e. series/historical data performed with combinations of iliac autograft/allograft and plates). Methods: We focused on the clinical outcomes, fusion rates, postoperative radiographic changes/lordosis/ subsidence, and/or reoperation rates for various PEEK ACDF constructs vs. "routine" ACDF. Results: One to 3 and 4-level PEEK ACDF cages demonstrated high fusion rates, few cage failures, and low reoperation rates. Subsidence for PEEK ACDF cages did not reduce fusion rates or diminish the quality of postoperative outcomes. Further, titanium-coated (T-C) PEEK cages lowered fusion rates in one study (i.e. 44.1% fusions vs. 88.2% for routine PEEK ACDF) while ACDF PEEK cages coated with hydroxyapatite (HA) showed only a "trend" toward enhanced arthrodesis. Conclusion: One to 3-4 multilevel ACDF PEEK cage constructs demonstrated comparable safety/efficacy when compared with each other, or in select cases, with "routine" ACDF (i.e. using autograft/allograft and plates).

11.
Diagnostics (Basel) ; 11(11)2021 Nov 12.
Article in English | MEDLINE | ID: mdl-34829440

ABSTRACT

Digital tomosynthesis (DTS) is a new imaging technique derived from radiography, and its usefulness has been gradually reported in the field of orthopedic diagnosis in recent years. A fully hydroxyapatite (HA)-coated stem, which is used for total hip arthroplasty (THA), is a type of cementless stem that has been widely used recently and reported to have good results. However, stem loosening on plain radiographs is difficult to determine in some cases due to cancellous condensation around the stem. In this retrospective cross-sectional study, we compared the results of plain radiography versus DTS to evaluate the imaging findings after THA using a fully HA-coated stem. Twenty joints each in the 3 y and 1 y postoperative groups underwent plain radiography and DTS. On DTS, bone formation around the stem was confirmed in all cases; however, this formation was not reproducible on plain radiography, and there were cases in which the reaction could not be confirmed or cases with cancellous condensation resembling reactive lines. This reaction was not reproducible on plain radiographs, and in some cases, the reaction could not be confirmed, or there were cases with cancellous condensation that resembled reactive lines. Therefore, DTS was useful in the diagnosis of bone formation around the implant.

12.
J Spine Surg ; 7(2): 155-161, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34296027

ABSTRACT

BACKGROUND: The proper diagnosis and treatment of sacroiliac joint (SIJ) pain remains a clinical challenge. Dysfunction of the SIJ can produce pain in the lower back, buttocks, and extremities. The present prospective clinical study is a follow-up report on a previous 1-year report on the use of a novel hydroxyapatite (HA)-coated titanium screw for the surgical treatment of SIJ dysfunction. METHODS: Data were prospectively collected on 32 consecutive patients who underwent minimally invasive SIJ fusion with a novel HA-coated screw. Clinical assessments and radiographs were collected and evaluated at 24 months postoperatively. RESULTS: Mean preoperative visual analog scale (VAS) back, left, and right leg pain scores decreased significantly to 20.0 (±18.4), 5.8 (±8.1), and 11.5 (±20.1) at 24-month follow-up, respectively. Oswestry Disability Index (ODI) scores significantly decreased to 27.5 (±18.8) points at 24 months (P<0.01). Two patients who required revision surgery reported improvement of their symptoms within 3 weeks and did not require subsequent surgery to be performed. CONCLUSIONS: This study shows positive clinical and functional outcomes for patients who have undergone fusion using HA-coated screws for SIJ dysfunction. SIJ fusion using a HA-coated screw to treat SIJ dysfunction significantly decreased VAS back and leg pain and ODI scores at 2-year follow-up.

13.
J Biomater Appl ; 36(3): 552-561, 2021 09.
Article in English | MEDLINE | ID: mdl-34162236

ABSTRACT

Despite advances in the pathogenesis of Tauroursodeoxycholic acid (TUDCA) on bone, the understanding of the effects and mechanisms of bone osseointegration in TUDCA-associated Hydroxyapatite (HA)-coated titanium implants remains poor. Therefore, the present work was aimed to evaluate the effect of local administration with TUDCA on HA-coated titanium implants osseointegration in ovariectomized(OVX) rats and further investigation of the possible mechanism. Twelve weeks after bilateral ovariectomy, all animals were randomly divided into three groups: sham operation(Sham) group, OVX group and TUDCA group, and all the rats from Sham group and OVX group received HA implants and animals belonging to group TUDCA received TUDCA-HA implants until death at 12 weeks. The bilateral femurs of rats were harvested for evaluation. TUDCA increased new bone formation around the surface of titanium rods and push-out force other than group OVX. Histology, Micro-CT and biochemical analysis results showed systemic TUDCA showed positive effects than OVX group on bone formation in osteopenic rats, with beneficial effect on via activation OPG/RANKL pathway and BMP-2/Smad1 pathway and microarchitecture as well as by reducing protein expression of TNF-α and IFN-γ. The present study suggests that local use of TUDCA may bring benefits to the osseointegration of HA-coated titanium implants in patients with osteoporosis, and this effect may be related to the inhibition of inflammatory reaction and promotion of osteogenesis.


Subject(s)
Coated Materials, Biocompatible/chemistry , Durapatite/chemistry , Osseointegration/drug effects , Taurochenodeoxycholic Acid/pharmacology , Titanium/chemistry , Animals , Female , Ovariectomy , Prostheses and Implants , Rats , Rats, Sprague-Dawley , Taurochenodeoxycholic Acid/administration & dosage
14.
Adv Clin Exp Med ; 30(6): 633-640, 2021 06.
Article in English | MEDLINE | ID: mdl-33984195

ABSTRACT

BACKGROUND: Sinus lift with a simultaneous implant placement in the residual maxilla is a common technique used worldwide. Nevertheless, choosing an ideal grafting material remains an object of dispute. The use of an autologous blood-derived graft, known as platelet-rich fibrin (PRF), has not yet been recognized to be as good as xenografts and alloplastic materials. However, initial results have been promising. OBJECTIVES: To conduct a clinical and radiological comparison of implantation with a simultaneous sinus lift using xenograft or PRF clots. MATERIAL AND METHODS: Thirty sinus lifts with simultaneous implantation were conducted using a lateral window approach and the tent pole technique, with xenograft (group 1 (G1)) or PRF (group 2 (G2)) as a filling material. To be included in the study, patients must have had an alveolar ridge height of 4-5 mm, no signs of inflammatory processes, good oral hygiene, and no other grafting procedures performed in region of implant insertion. In each case, the measurements taken were probing pocket depth (PPD), height of keratinized tissue (HKT), clinical attachment level (CAL), recession depth/width (RD/RW), and, on panoramic X-rays, marginal bone loss (MBL), grafted sinus high (GSH), and bone gain (BG). Preand post-operative treatment was applied to reduce the chance of infection. RESULTS: During the study, 30 implants (hydroxyapatite-coated implants manufactured by SGS - 10 mm in length and 4.2 mm in diameter) were placed. The survival rate of implants in both groups was 100% with no implant mobility, pain, paresthesia, or inflammatory processes in the direct vicinity of the implants observed, except in 1 patient. After 36 months of follow-up, the radiological assessments for G1 were: GSH 4.5 mm, MBL 0.46 mm and BG 4.53 mm; and for G2: 3.4 mm, 0.6 mm and 3.4 mm, respectively. Results of the clinical measurements were for G1: HKT after 36 months (HKT36) 2.46 mm, CAL 0.47 mm and PPD 2 mm; and for G2: HKT36 3.13 mm, CAL 0.6 mm and PPD 2.07 mm. CONCLUSIONS: After 3 years of follow-up, the results of sinus lifting solely using PRF with simultaneous implantation were promising, especially in terms of soft tissue management. Therefore, PRF can be regarded as an alternative to previously used materials.


Subject(s)
Dental Implants , Platelet-Rich Fibrin , Bone Transplantation , Follow-Up Studies , Heterografts , Humans , Maxilla , Maxillary Sinus , Retrospective Studies
15.
Bone Joint J ; 103-B(5): 958-963, 2021 May.
Article in English | MEDLINE | ID: mdl-33934651

ABSTRACT

AIMS: The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively. METHODS: A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time. RESULTS: Stress shielding was graded as mild in 14 shoulders and moderate in three; the greater tuberosity was the predominant site for stress shielding. The mean metaphyseal and diaphyseal fill-fit ratios were 0.56 (SD 0.1) and 0.5 (SD 0.07), respectively. For shoulders with no radiologically visible stress shielding, the mean decrease in grey value in zones 1 and 7 was 20%, compared with 38% in shoulders with radiologically visible stress shielding. CONCLUSION: The rate of moderate stress shielding was 7%, five years after implantation of a cementless standard-length HA-coated humeral component. Clinical observation of stress shielding identified on radiographs seems to represent a decrease in grey value of 25% or more. Cite this article: Bone Joint J 2021;103-B(5):958-963.


Subject(s)
Arthroplasty, Replacement, Shoulder/instrumentation , Humerus/surgery , Prosthesis Design , Shoulder Prosthesis , Adolescent , Adult , Aged , Coated Materials, Biocompatible , Durapatite , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted
16.
Exp Ther Med ; 21(5): 541, 2021 May.
Article in English | MEDLINE | ID: mdl-33815614

ABSTRACT

Osteoarthritis is mainly located in the knee area. It is an important concern related to the population health, determined by the influence on the quality of life of patients. Total knee arthroplasty (TKA) with uncemented fixation is among the most encountered procedures performed in patients of a younger age. The present study investigated the response of patients (quality of life, mobility and pain management) with titanium/hydroxyapatite-coated implants with polyethylene inserts. A total of 57 patients with knee arthroplasty were studied with an average age of 54.1±4.9 years and 57.8% were females. The present study focused on the following aspects: The components of such a prosthesis and the way they contribute to a physiological fixation/recovery; how the implant surgery is performed; the clinical and demographic characteristics of the patients; postoperative pain assessment in different types of movement; the management of the movement capacity 1 year after the surgery; and complications that may occur. One year after the surgery, these patients reported pain release, considerably favorable results in every-day activities, and good mobility (capable of using the car, rising from the bed or standing). Knowledge and accurate observation of the correct steps in performing this surgery and the role of the components of the prosthesis can lead to favorable therapeutic outcomes for patients with knee osteoarthritis.

17.
J Clin Med ; 9(7)2020 Jul 02.
Article in English | MEDLINE | ID: mdl-32630629

ABSTRACT

(1) Background: High primary stability is important for the long-term survival of cementless femoral stems in total hip arthroplasty (THA). The objective of this study was to investigate the migration pattern of a hydroxyapatite-coated cementless hip stem developed for minimally invasive surgery using model-based radiostereometric analysis (RSA). (2) Methods: In this randomized controlled trial, 44 patients with an indication for cementless primary THA were randomly allocated to receive either the SL-PLUS MIA stem, developed for minimally invasive surgery, or the SL-PLUS stem (Smith & Nephew Orthopaedics, Baar, Switzerland) which served as a control group. Unlimited weight-bearing was permitted postoperatively in both groups. Model-based RSA was performed after six weeks and after 3, 6, 12 and 24 months postoperatively. (3) Results: Mean total stem subsidence at two-year follow-up was 0.40 mm (SD 0.66 mm) in the SL-PLUS group and 1.08 mm (SD 0.93 mm) in the SL-PLUS MIA group (p = 0.030). Stem subsidence occurred during the first six weeks after surgery, indicating initial settling of the stem under full weight-bearing. Both stem designs showed good osseointegration and high secondary stability with no further migration after initial settling. (4) Conclusions: Settling of a cementless straight femoral stem occurs during the first six weeks after surgery under full weight-bearing. Although initial stem migration was higher in the SL-PLUS MIA group, it had no influence on secondary stability. All implants showed good osseointegration and high secondary stability with no signs of implant loosening during this two-year follow-up period.

18.
J Arthroplasty ; 34(9): 2011-2015, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31182412

ABSTRACT

BACKGROUND: Good bone quality and proper proximal femoral morphology are thought to be necessary for tapered design, cementless femoral stems to resist subsidence. Using tapered, cementless stem for patients with stovepipe morphology or Dorr type C is controversial. The purpose of this study is to analyze (1) subsidence of the fully hydroxyapatite (HA)-coated, tapered, cementless stem in different morphology according to Dorr classification, (2) subsidence of the stem related to radiographic canal-fill ratio. METHODS: The digitized radiographs of 311 consecutive cementless primary total hip arthroplasty with fully HA-coated, tapered stem were retrospectively reviewed. Subsidence and the canal-fill ratio at 4 locations were evaluated postoperatively after a minimum of 2 years of follow-up. The threshold of subsidence >3 mm was considered as a clinically significant migration. RESULTS: A multivariate regression analysis of subsidence across Dorr type, controlling for age, gender, and intraoperative calcar fracture, demonstrated 0.40 mm (P = .28) and 0.18 mm (P = .51) greater subsidence in Dorr type C and B when compared to Dorr type A. Age, gender, and calcar fracture had no influence on subsidence, whereas greater canal-fill ratio at 2 cm below lesser trochanter resulted in significantly less subsidence (P = .02). Additionally, all variables did not affect the risk of having subsidence >3 mm. CONCLUSION: The proximal femoral morphology has no statistically significant effect on the subsidence of fully HA-coated stem. Therefore, this stem type might be a viable option for Dorr type C. Increasing the canal-fill ratio at metadiaphyseal junction may ensure the stability of the stem.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Coated Materials, Biocompatible/chemistry , Durapatite/chemistry , Hip Prosthesis , Aged , Bone Cements , Female , Femur/surgery , Humans , Male , Middle Aged , Postoperative Period , Prosthesis Design , Retrospective Studies
19.
Eur J Orthop Surg Traumatol ; 29(3): 611-618, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30488136

ABSTRACT

Studies over the past decade have reported that the use of highly porous sockets in total hip arthroplasty (THA) results in osseointegration and long-term implant stability. However, some reports have raised concerns regarding radiographic evidence of poor osseointegration with features of fibrous tissue ingrowth. The purpose of this study was to compare clinical and radiographic assessments of highly porous sockets with those of hydroxyapatite (HA)-coated porous sockets in THA for hip dysplasia (DDH) at least 1 year after surgery. A total of 127 patients (136 hips) were recruited for the study. Of these, 94 patients (101 hips) received highly porous sockets with clustered screws, while 33 patients (35 hips) received HA-coated porous sockets with clustered screws. There was no difference in clinical outcomes between the two types of sockets. All HA-coated porous sockets were radiographically stable, without radiolucent lines. Fifteen hips had radiolucent lines in two or three DeLee and Charnley zones, accompanied by sclerotic lines along the circumferences of the highly porous sockets. A significant difference in the height of the preoperative osteophyte of the anterior acetabular wall was observed between 86 hips with one or no radiolucent lines and 15 hips with two or three radiolucent lines. In cases of DDH with atrophic bone remodeling pattern, highly porous sockets with multiple screws may be used, while HA-coated porous sockets with clustered screws result in better sealing of the bone-component interface.


Subject(s)
Durapatite , Hip Dislocation/surgery , Hip Joint/diagnostic imaging , Hip Prosthesis , Osseointegration , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip , Female , Follow-Up Studies , Hip Dislocation/diagnostic imaging , Humans , Male , Middle Aged , Radiography , Retrospective Studies
20.
Nanomaterials (Basel) ; 7(12)2017 Dec 04.
Article in English | MEDLINE | ID: mdl-29207552

ABSTRACT

Targeting cancer cells without injuring normal cells is the prime objective in treatment of cancer. In this present study, solvothermal and wet chemical precipitation techniques were employed to synthesize iron oxide (IO), hydroxyapatite (HAp), and hydroxyapatite coated iron oxide (IO-HAp) nanoparticles for magnetic hyperthermia mediated cancer therapy. The synthesized well dispersed spherical IO-HAp nanoparticles, magnetite, and apatite phases were confirmed by X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR) and Field emission transmission electron microscopy (FETEM) with Energy Dispersive X-ray spectroscopy (EDS). The non-toxic behavior of synthesized IO-HAp nanoparticles was confirmed by cytotoxicity assay (Trypan blue and MTT assay). The synthesized nanoparticles revealed a remarkable magnetic saturation of 83.2 emu/g for IO and 40.6 emu/g for IO-HAp nanoparticles in presence of 15,000 Oe (1.5 T) magnetic field at room temperature (300 K). The magnetic hyperthermia study that was performed with IO-HAp nanoparticles showed an excellent hyperthermia effect (SAR value 85 W/g) over MG-63 osteosarcoma cells. The in vitro hyperthermia temperature (~45 °C) was reached within 3 min, which shows a very high efficiency and kills nearly all of the experimental MG-63 osteosarcoma cells within 30 min exposure. These results could potentially open new perceptions for biomaterials that are aimed for anti-cancer therapies based on magnetic hyperthermia.

SELECTION OF CITATIONS
SEARCH DETAIL
...