1.
Int Ophthalmol ; 44(1): 240, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38904711

ABSTRACT

PURPOSE: To clarify the characteristics of intraocular lens (IOL) dislocation requiring IOL suture or intraocular scleral fixation. METHODS: This retrospective consecutive case series included 21 eyes (21 patients) who required sutured or sutureless intrascleral IOL fixation following IOL extraction owing to IOL dislocation at the outpatient clinic in the Department of Ophthalmology, Saitama Red Cross Hospital, Japan, between January and December 2019. Medical records were retrospectively reviewed for background diseases, location of the dislocated IOL (intracapsular/extracapsular), insertion of a capsular tension ring (CTR), and the period from IOL insertion to dislocation. RESULTS: We included 21 eyes of 21 patients who required IOL suture or intrascleral fixation for IOL dislocation at our clinic from January to December 2019 were included. The most common background disease was pseudoexfoliation syndrome (four cases), followed by atopic dermatitis, dysplasia/dehiscence of the zonule, post-retinal detachment surgery, high myopia, and uveitis (three cases each). At the time of dislocation, the IOLs were either intracapsular (16 cases, including 3 cases with CTR insertion) or extracapsular (5 cases). The time from IOL insertion to IOL dislocation was 13.7 ± 8.1 years (maximum: 31.3 years, minimum: 1.7 years). CONCLUSIONS: In this study, all 21 cases represented late IOL dislocations occurring after 3 months postoperatively. Among these late IOL dislocation cases, IOL dislocation occurred in a short-medium period of time, especially in those with CTR insertion and weakness/dehiscence of the zonule, with an average of 3 to 5 years postoperatively. We propose referring to these cases as intermediate-term IOL dislocation.


Subject(s)
Artificial Lens Implant Migration , Lenses, Intraocular , Humans , Retrospective Studies , Female , Male , Aged , Middle Aged , Artificial Lens Implant Migration/surgery , Artificial Lens Implant Migration/etiology , Artificial Lens Implant Migration/diagnosis , Lenses, Intraocular/adverse effects , Aged, 80 and over , Time Factors , Visual Acuity , Adult , Sclera/surgery , Suture Techniques , Follow-Up Studies , Lens Implantation, Intraocular/methods , Lens Implantation, Intraocular/adverse effects , Postoperative Complications
2.
Clin Ophthalmol ; 18: 315-324, 2024.
Article in English | MEDLINE | ID: mdl-38332906

ABSTRACT

Purpose: We compare and evaluate the visual outcome and complication rate of two different techniques of surgical management of in-the-bag intraocular lens (IOL) dislocation or aphakia correction. In addition, we evaluate possible risk factors for IOL dislocation or aphakia. Patients and Methods: This retrospective case series reviewed medical records for all patients who had undergone surgery for IOL dislocation or aphakia during a 5-year period at a single ophthalmic center in Sweden. The two most common procedures, scleral suturing of dislocated in-the-bag IOL and retropupillary fixation of iris-claw IOL, were further analyzed. Main outcome measures were best-corrected visual acuity (BCVA), reoperations, and complications. Results: The study comprised 110 eyes, including scleral suturing procedures (n=35) and retropupillary iris-claw IOL (n=75). There was a significantly higher rate of dense cataract (p=0.030) and posterior capsular rupture (PCR), (p=0.016) among iris-claw cases at the primary cataract extraction with pseudoexfoliations in about two-thirds of patients in both groups. All eyes in the scleral suturing group had an IOL dislocation. In the iris-claw group, 23 eyes (30.7%) were aphakic following complicated cataract surgery with PCR. No intraoperative complications occurred in any eyes during the secondary IOL procedure. Both groups showed significant improvement in BCVA, yet there was no significant difference between groups in postoperative BCVA (p=0.263). However, the scleral suturing group experienced a significantly larger improvement in BCVA due to worse BCVA preoperatively (p=0.005). Intraocular pressure decreased significantly after both repositioning and exchange surgery (p=0.002 and 0.010 respectively), but improvement between groups was not significantly different (p=0.264). Conclusion: Both surgical methods resulted in significantly improved BCVA and lowering of IOP and can be considered safe with limited complications. The outcome was similar between groups. Pseudoexfoliation prevalence was high in both groups indicating that it may be a risk factor for either aphakia or late IOL dislocation.

3.
Acta Ophthalmol ; 102(3): 306-311, 2024 May.
Article in English | MEDLINE | ID: mdl-37303305

ABSTRACT

PURPOSE: To investigate the inflammatory reaction in eyes with late in-the-bag intraocular lens (IOL) dislocation. METHODS: This prospective clinical study with fellow-eye comparison consists of 76 of the patients (76 eyes) with late in-the-bag IOL dislocation enrolled in the LION trial. The main outcome measure was anterior chamber flare before surgery measured with a laser flare meter in photon counts per millisecond (pc/ms). The dislocation was graded as 1 (small: optic still covering the visual axis), 2 (optic equator close to the visual axis) or 3 (optic decentred beyond the visual axis, but the IOL-capsule complex partly visible in the pupillary area). The secondary aim was to compare intraocular pressure (IOP) before surgery. RESULTS: Flare levels before surgery were significantly higher in the dislocation eyes than in the fellow eyes with a median flare of 21.5 (range 5.4-135.7) pc/ms versus 14.1 (2.0-42.9) pc/ms, respectively (p ˂ 0.001). A regression analysis of log-transformed flare values showed that the dislocation eyes had a non-significant tendency towards higher flare in dislocation grade 1 with a median flare of 24.6 (5.4-135.7) pc/ms compared to grade 2; 19.6 (6.5-41.5) pc/ms (p = 0.06), and no significant difference compared to grade 3; 19.4 (10.2-53.5) pc/ms (p = 0.47). The IOP was significantly higher in the dislocation eyes than in the fellow eyes (p ˂ 0.001). CONCLUSIONS: Eyes with late in-the-bag IOL dislocation had increased flare levels compared to their fellow eyes. This suggests that inflammation is part of the clinical picture of late in-the-bag IOL dislocation.


Subject(s)
Eye Diseases , Lens Subluxation , Lenses, Intraocular , Humans , Lenses, Intraocular/adverse effects , Prospective Studies , Postoperative Complications/surgery , Inflammation/diagnosis , Inflammation/etiology , Lens Subluxation/surgery
4.
Ophthalmol Ther ; 11(3): 1251-1260, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35290644

ABSTRACT

INTRODUCTION: To describe the outcomes of retropupillary iris fixation of an iris claw Artisan Myopia intraocular lens (IOL), and to review literature on retropupillary iris fixation of iris claw models for myopia for the correction of aphakia and IOL dislocation in eyes with extremely high myopia. METHODS: Single-center, retrospective case series. Three patients (three eyes) with pathological myopia underwent retropupillary iris fixation of the iris claw Artisan Myopia model 204 for the correction of aphakia and IOL dislocation. After IOL power calculation, we found that the Artisan Aphakia IOL was not available for these patients. One patient had a history of previous extracapsular cataract extraction and two patients exhibited IOL-bag complex dislocation. The target lens power was calculated using ultrasound biometry and the Sanders-Retzlaff-Kraff theoretical and T2 formulae, with an A-constant of 103.8. All surgeries were performed by a single surgeon. Visual outcomes were assessed at 12-48 months after surgery. RESULTS: The mean axial length was 34.33 ± 0.21 mm. The power of the implanted Artisan IOLs ranged between - 4.00 and - 3.00 diopter. The corrected distance visual acuity, measured in logarithm of the minimum angle of resolution units, improved after surgery in all eyes, from 0.60 ± 0.36 logMAR before surgery to 0.40 ± 0.43 logMAR after surgery at 12 months postoperatively and remained stationary thereafter. There were no postoperative complications. CONCLUSIONS: Retropupillary iris fixation of Artisan Myopia IOLs may be a safe and effective surgical treatment option for the correction of aphakia and IOL dislocation in patients with extremely high myopia.

5.
J Clin Med ; 10(17)2021 Aug 26.
Article in English | MEDLINE | ID: mdl-34501279

ABSTRACT

BACKGROUND: We investigate the incidence and characteristics of IOL dislocation among the pseudophakic population after phacoemulsification. METHODS: National data were collected from the health claims recorded with the Health Insurance Review and Assessment Service of South Korea from 2009 to 2016. Pseudophakic patients aged 40 years or older were included. The incidence estimates of phacoemulsification and IOL dislocation were analyzed, and the cumulative probabilities of IOL dislocation among the pseudophakic population and general population were calculated as a proportion. RESULTS: Of 51,307,821 total subjects, 25,271,917 of whom were aged 40 years or older, 3,906,071 cataract cases in 2,650,104 pseudophakic patients were identified, and 72,309 patients experienced IOL dislocation. The cumulative probability was 2.73% per person and 1.85% per surgery among patients 40 years of age or older. The eight-year incidence rate for IOL dislocation in the pseudophakic population aged 40 years or older was 7671 per 1,000,000 person-years (95% CI: 7616-7727), including 10,341 cases in men and 5814 in women. Incidence peaked in the seventh decade of life for cataract surgery but in the fifth decade of life for IOL dislocation. The cumulative probability of IOL dislocation after phacoemulsification was approximately 2%, and the incidence rate was about 7000 per 1,000,000 pseudophakic patients. CONCLUSIONS: There was a significantly higher incidence of IOL dislocation among young males, even though the higher incidence of cataract surgery was observed among older females. These estimates of the nationwide, population-based incidence of IOL dislocation can help increase understanding of the population vulnerable to IOL dislocation.

6.
Clin Ophthalmol ; 15: 2727-2739, 2021.
Article in English | MEDLINE | ID: mdl-34211261

ABSTRACT

Retropupillary iris-claw intraocular lenses (ICIOLs) have been increasingly chosen by surgeons nowadays as a primary or secondary procedure of IOL implantation in eyes with insufficient capsular or zonular support. They have gained popularity due to their simple fast technique, favourable functional outcomes, and safety. The transition in the ICIOL fixation from prepupillary to a more biologically appropriate retropupillary position and change in the optic design from biconvex to convex-concave have provided better visual outcomes and improved safety. A peer-reviewed literature search was conducted in Medline (PubMed), Embase, and Cochrane Library using the keywords "retropupillary iris claw" and "iris claw". The search yielded 310 articles that were screened. Forty-three articles on retropupillary ICIOLs were finally found to be relevant and reviewed in full-text versions. The functional outcomes following retropupillary implantation of ICIOLs have been acceptable in eyes with no ocular co-morbidities otherwise. However, the indications for surgery may affect the outcomes. The major postoperative complications directly associated with ICIOLs include pupil ovalization and redislocation. Nevertheless, the rate of disenclavation depends on the experience and skill of the surgeon. This review is based on a literature review, and it focuses on the preoperative evaluation, surgical technique, postoperative outcomes, and associated complications. Prospective randomized trials with a larger sample size and longer follow-up are needed for comparison with other techniques of IOL fixation and confirmation of long-term safety profile.

7.
Int Med Case Rep J ; 14: 95-100, 2021.
Article in English | MEDLINE | ID: mdl-33628063

ABSTRACT

PURPOSE: A late dislocation of an in-the-bag intraocular lens (IOL) is strongly associated with pseudoexfoliation and less with retinitis pigmentosa, prior vitreoretinal surgery, and uveitis. We present our findings of late in-the-bag IOL dislocation in three patients with multiple chorioretinal atrophy associated with sarcoidosis. METHODS: Observational study of three elderly female Japanese patients with a history of uveitis from sarcoidosis who presented with a late dislocation of an in-the-bag IOL. RESULTS: The late in-the-bag IOL dislocation occurred in the convalescent/quiescent stage of the sarcoidosis. Peripheral multifocal chorioretinal atrophy was the main manifestation in all patients who were diagnosed with definite or presumed sarcoidosis. The dislocated IOLs were successfully removed and new IOLs were implanted with scleral suture fixation followed by no remarkable active uveitis. CONCLUSION: Clinicians should be aware that patients with peripheral multifocal chorioretinal atrophy associated with sarcoidosis can have a late in-the-bag IOL dislocation.

8.
Am J Ophthalmol Case Rep ; 20: 100893, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32913925

ABSTRACT

PURPOSE: To present the surgical value of femtosecond laser capsulotomy in the treatment of capsular contraction. OBSERVATIONS: The clinical case of a 63-year-old male patient with single eye who, two months after cataract surgery without complications, presented a significant dislocation of the secondary intraocular lens due to a capsule contraction and epithelial metaplasia that covered the lens optics and caused low vision. CONCLUSIONS: The femtosecond laser-assisted capsulotomy proved to be effective and safe with minimal traction on the zonule and no IOL damage, in this patient with a follow-up of 29 months.

9.
Int Ophthalmol ; 40(6): 1455-1460, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32076963

ABSTRACT

AIM: To evaluate the visual outcomes of the patients who had undergone sutureless scleral fixated IOL implantation operation in which a new modified Yamane technique called flattened flanged intrascleral intraocular lens fixation technique was applied. MATERIALS AND METHODS: Forty-two eyes of 42 patients who had undergone scleral IOL fixation operation with Yamane technique comprised Group 1. The mean age of this group was 60.24 ± 14.3 (20-77) years. Out of 42 patients, 25 of them (60%) were males and 17 of them (40%) were females. Forty-three eyes of 43 patients who had undergone scleral IOL fixation operation with flattened flange technique comprised Group 2. The mean age of this group was 55.35 ± 15.77 (18-79) years. Out of 43 patients, 23 (53.4%) of them were males and 20 (46.6%) were females. RESULTS: There were no significant differences between two groups in respect to mean preoperative UCVA, postoperative UCVA, preoperative BCVA, and postoperative BCVA (p values 0.35, 0.11, 0.28, and 0.16, respectively). The mean postoperative UCVA and preoperative BCVA were significantly higher than those of preoperative values in both groups (p < 0.05). Intraoperative haptic sliding occurred in three eyes (7%) in the first group, and there was no intraoperative haptic sliding in the second group (0%) (p = 0.05). Postoperative IOL dislocation occurred in one eye (2.5%) in the first group, and there was no postoperative IOL dislocation in the second group (0%) (p = 0.32). CONCLUSION: In conclusion, this technique does not require sutures, decreases intraoperative haptic sliding, may provide more IOL stability and less tilt, and facilitates the implantation of the second haptic. For long-term results, further studies should be conducted.


Subject(s)
Aphakia, Postcataract/surgery , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Sclera/surgery , Sutureless Surgical Procedures/methods , Visual Acuity , Adolescent , Adult , Aged , Aphakia, Postcataract/physiopathology , Female , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Young Adult
10.
Int Ophthalmol ; 40(2): 313-323, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31565759

ABSTRACT

PURPOSE: To evaluate the causes of IOL explantation, techniques for secondary IOL implantation, visual outcomes and complications. METHODS: Setting: Department of Ophthalmology Complexo Hospitalario Universitario A Coruña, Spain. DESIGN: Retrospective study. All explanted IOLs from January 2010 to June 2018 were included. Medical records were reviewed to determine the surgical indication for IOL explantation, type of IOL implanted, time between surgeries, visual outcomes and surgical complications. RESULTS: One hundred forty-one IOLs were explanted (134 patients). Mean time from original surgery to IOL explantation was 7.89 ± 5.81 years. Causes of IOL explantation were IOL dislocation (81.56%)-in-the-bag IOL dislocation (71.63%), out-of-the-bag IOL dislocation (9.9%)-corneal decompensation (12.05%), refractive surprise (3.5%), uveitis-glaucoma-hyphema syndrome (1.4%), IOL opacification (1.4%). Procedures for secondary IOL implantation were retropupillar iris-claw IOL (63.8%), flanged scleral fixated IOL (9.2%), three-piece IOL in ciliary sulcus (8.5%), angle-supported anterior chamber IOL (7.1%), in-the-bag IOL (3.5%), scleral fixated IOL with sutures (0.7%). Ten cases (7.1%) were left aphakic. Mean preoperative and postoperative logMAR CDVA were 1.34 ± 0.87 and 0.63 ± 0.69, respectively (p = 0.000). Mean preoperative IOP and postoperative IOP were 16.78 ± 4.49 and 15.53 ± 3.476 mmHg, respectively (p = 0.005). Complications include cystoid macular edema (7.8%), glaucoma (7.1%), IOL luxation (2.1%), retinal detachment (1.4%), trophic ulcer and leucoma (1.4%), corneal decompensation (1.4%). CONCLUSIONS: In-the-bag IOL dislocation was the most frequent indication for IOL explantation, followed by pseudophakic bullous keratopathy. Simultaneous IOL exchange for a retropupillar iris-claw IOL was the most frequent procedure for secondary IOL implantation. Mean CDVA improved significantly and IOP decreased significantly after IOL explantation. The most frequent postoperative complication was cystoid macular edema.


Subject(s)
Device Removal/methods , Lenses, Intraocular/adverse effects , Postoperative Complications/surgery , Tertiary Care Centers , Visual Acuity , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Postoperative Complications/epidemiology , Retrospective Studies , Spain/epidemiology
11.
Int J Ophthalmol ; 12(6): 954-960, 2019.
Article in English | MEDLINE | ID: mdl-31236352

ABSTRACT

AIM: To evaluate the possible predisposing risk factors for late in-the-bag spontaneous IOL dislocations and to study the early surgical and visual outcomes of repositioning and exchange surgeries. METHODS: Medical and surgical records of 39 eyes of 39 patients who underwent IOL repositioning or exchange surgery for dislocation between 2010 and 2018 were reviewed. Possible predisposing risk factors and some characteristics of late in-the-bag spontaneous IOL dislocations; outcomes of IOL repositioning and exchange surgeries, including visual acuity, refractive status before and after surgery and postoperative complications were evaluated. RESULTS: The predisposing factors for late in-the-bag spontaneous IOL dislocations were pseudoexfoliation [PEX; 12/39 (30.8%)], previous vitreoretinal surgery [7/39 (17.9%)], axial myopia [3/39 (7.7%)], both PEX and axial myopia [1/39 (2.6%)], both previous vitreoretinal surgery and axial myopia [2/39 (5.1%)] and uveitis [1/39 (2.6%)]. The mean interval between cataract and dislocation surgery was 7.23y, greater in PEX positive group (8.63y). The mean best corrected visual acuity (BCVA) improved significantly after dislocation surgery (P<0.001) and also improved significantly after exchange surgery (P=0.001). The mean value of spherical equivalant decreased significantly after dislocation surgery (P=0.011), whereas corneal astigmatism increased but this difference was not significant after dislocation surgery and exchange surgery (P=0.191, P=0.074, respectively). CONCLUSION: The most prevelant risk factors for late in-the-bag spontaneous IOL dislocations are PEX, previous vitreoretinal surgery and axial myopia. In the management of IOL dislocations, exchange surgery with small corneal incision seemed effective with improved BCVA and safety with low postoperative complications.

12.
Jpn J Ophthalmol ; 63(1): 65-72, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30426259

ABSTRACT

PURPOSE: To describe relevant patient demographic characteristics and investigate the influence of known risk factors for late intraocular lens (IOL) dislocation. To explore the associations between these risk factors and the incidence of recurrent IOL dislocation. STUDY DESIGN: Retrospective cohort study. METHODS: This study was performed using Nationwide Diagnostic Procedure Combination data in Japan from April 1, 2008 through July 31, 2016. Descriptive statistics for late and recurrent IOL dislocation, incidence rates, and risk factors for recurrent IOL dislocation were analyzed using a Cox proportional hazard model. RESULTS: We identified 678 patients with late IOL dislocation. Most were men (72%, 488/678), and the men were younger than their women counterparts (mean age 65.2 years vs. 74.5 years). The incidence rate of recurrent IOL dislocation was 5.1 per 100 person-years. All 20 cases of recurrent IOL dislocation were observed within the year following surgery. There were no significant associations between potential risk factors and recurrent IOL dislocation (adjusted hazard ratio [HR] 1.53, 95% confidence interval [CI] 0.55-4.26 for diabetes mellitus; adjusted HR 0.77, 95%CI 0.09-6.40 for atopic dermatitis); no recurrences occurred in patients with pseudoexfoliation syndrome, retinitis pigmentosa, or connective tissue disease. CONCLUSIONS: Late IOL dislocation occurs more frequently in men. We found that recurrent IOL dislocation was rare during long-term follow-up and there were no significant associations between the potential risk factors and recurrent IOL dislocation. Further studies are needed to clarify the sex-related differences involved in IOL dislocation.


Subject(s)
Lens Subluxation/epidemiology , Ophthalmologic Surgical Procedures/methods , Risk Assessment , Aged , Female , Follow-Up Studies , Humans , Incidence , Japan/epidemiology , Lens Subluxation/diagnosis , Lens Subluxation/surgery , Male , Prognosis , Recurrence , Retrospective Studies , Risk Factors
13.
Adv Med Sci ; 64(1): 100-103, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30580205

ABSTRACT

PURPOSE: To analyze long-term visual outcomes and complications of the implantation of a scleralfixated posterior chamber intraocular lens (PC-IOL) in patients with the lack of adequate capsular support, and to verify if the procedure can be performed with 9-0 polypropylene sutures. METHODS: The study was designed as a long-term retrospective analysis. Patients after the implantation of a scleralfixated PC-IOL were evaluated for the best corrected visual acuity (BCVA), intraocular pressure and occurrence of postoperative complications. RESULTS: The analysis included 29 eyes from 28 patients. Indications for the IOL implantation included ocular trauma (89.7%) and previous complicated cataract surgery (10.3%). A postoperative improvement of BCVA was observed in 25 eyes (86.2%). Mean follow-up time was 63.9 months (range 50-83 months). During this time, six patients (21.4%) were diagnosed with glaucoma (21.4%), and retinal detachment was found in one eye (3.4%). A total of six suture breakages were recorded in four eyes from four patients (13.8%); one breakage was precipitated by a trauma, and another five, involving three eyes from three patients, were spontaneous. Mean time to the spontaneous suture breakage was 40.8 months. CONCLUSIONS: Scleral fixation of the PC-IOL provides satisfactory visual outcomes. However, this procedure is associated with a considerable risk of postoperative complications. The incidence of postoperative suture breakage in our series was similar as in previous studies in which the PC-IOL was fixated with 10-0 polypropylene suture. A superiority of 9-0 polypropylene suture needs to be verified in larger series of consecutive patients.


Subject(s)
Lens Implantation, Intraocular/adverse effects , Lenses, Intraocular/adverse effects , Polypropylenes/adverse effects , Postoperative Complications/etiology , Sclera/surgery , Sutures/adverse effects , Vision, Ocular , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
14.
BMJ Open Ophthalmol ; 3(1): e000174, 2018.
Article in English | MEDLINE | ID: mdl-30539150

ABSTRACT

OBJECTIVE: Intraocular lens (IOL) repositioning using a closed-eye approach could be carried out in some selected cases. Our study focuses on the efficacy and safety of a IOL closed-eye repositioning technique using scleral suture, which is performed using a trocar as an intrastromal limbal guide. METHODS AND ANALYSIS: Thirty-one eyes of 31 patients with late IOL dislocation operated on between January 2015 and May 2017 were included in this retrospective non-comparative consecutive case series study. The patients had a single-piece in-the-bag dislocation or a 3-pieces in-the-bag or out-of-the-bag dislocation. The patients underwent an anterior vitrectomy and a scleral refixation in a closed chamber using a 10/0 polypropylene suture passed through a 25 Gauge trocar inserted in the anterior chamber. RESULTS: The mean follow-up time was 19.54 months. Average preoperative best-corrected visual acuity (BCVA) was 0.73 LogMar (±0.21 SD); while average postoperative BCVA was 0.27 LogMar (±0.23 SD). Fifteen patients underwent anterior pars plana vitrectomy (PPV) while 16 patients did not; moreover, two patients underwent PPV. Six patients had an increase of postoperative intraocular pressure, two patients had postoperative decentration, two patients had postoperative cystoid macular oedema, none of the patients had major complications such as retinal detachment, choroidal detachment, malignant glaucoma, irreversible corneal decompensation and endophthalmitis. CONCLUSION: We can affirm that our technique may be safe and useful in the case of 3-piece in-the bag or out-of the bag dislocated IOLs and also in the case of in-the-bag single-piece dislocated IOLs.

15.
Int Ophthalmol ; 38(5): 2183-2186, 2018 Oct.
Article in English | MEDLINE | ID: mdl-28801741

ABSTRACT

Purpose We describe a scleral suture fixation technique for dislocated plate haptic toric intraocular lens (IOL) implantation. Materials and methods A double-armed 10-0 straight polypropylene suture was passed into the eye from the sclera (2 mm away from the limbus). A suture needle was passed through the hole on the corner of the IOL and pulled out from the paracentesis with a 27-gauge needle. Afterward, the suture needle was reinserted from the same paracentesis and then removed from the eye with the help of a 27-gauge needle entering the eye from a nearby point to the first scleral entrance. The needle was passed through the end of the loop and pulled slightly to initiate the formation of a cow-hitch knot. The same procedure was applied to the other hole on the plate haptic. Both sutures were adjusted and fixed to the sclera with a Z suture. Results No complications were observed and at the follow-up visits, uncorrected visual acuity was 0.8 with decimal. Conclusion Axial, sagittal, and rotational stability rules are taken into consideration, scleral fixation surgery for a dislocated plate haptic foldable toric IOL is an alternative method to eliminate astigmatic refractive error.


Subject(s)
Foreign-Body Migration/surgery , Lenses, Intraocular/adverse effects , Postoperative Complications , Sclera/surgery , Suture Techniques/instrumentation , Sutures , Female , Humans , Middle Aged , Prosthesis Design , Prosthesis Failure , Reoperation
16.
Int Ophthalmol ; 38(3): 909-915, 2018 Jun.
Article in English | MEDLINE | ID: mdl-28161802

ABSTRACT

PURPOSE: In cases of pupillary capture after previous transscleral fixation of an intraocular lens (IOL), an across-pupil suture technique is sometimes used to stabilize the IOL. We investigated the optical effects of 10-0 polypropylene sutures placed across the pupil. METHODS: Optical performance was evaluated using the optical bench metrology system, and a single-piece IOL was used in an optical bench system consisting of a model eye, a high-resolution Hartmann-Shack wave front sensor, and an image capturing device with 2.0, 3.0, 4.0, and 4.5 mm apertures with distance focus. To simulate across-pupil sutures, two 10-0 polypropylene sutures were placed 2 mm apart across the pupil. The focus image, spherical aberration, and image quality were measured and compared with and without sutures. RESULTS: When pupil size increased, spherical aberration increased, irrespective of sutures. No difference was found in spherical aberration with and without sutures, and image qualities at 17.6 and 35.2 cycles per degree were not affected by the across-pupil sutures. CONCLUSIONS: The differences in optical quality using across-pupil 10-0 polypropylene sutures were clinically negligible.


Subject(s)
Computer Simulation , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Optics and Photonics , Suture Techniques/instrumentation , Sutures , Humans , Prosthesis Design , Pupil , Visual Acuity
17.
Int Ophthalmol ; 38(4): 1765-1768, 2018 Aug.
Article in English | MEDLINE | ID: mdl-28676990

ABSTRACT

PURPOSE: To report a technique of intra-scleral fixation of the iris hooks for trans-scleral capsular bag fixation in patient with zonular dialysis. METHODS: Two scleral flaps, two scleral tunnels and two sclerotomies were formed. The anterior capsule was captured and pulled by the iris hooks resulting in the IOL adopting an appropriate position at which point the iris hooks extracted from the sclerotomies. The tips of the iris hooks were implanted into the scleral tunnels. Each of them was fixed with a 10.0 nylon suture to the scleral bed. The scleral flaps and conjunctiva were sutured. One of the iris hooks was seen loosened at the first-week postoperative examination but the IOL remained centralized. The loosened hook was removed. RESULTS: No complications were witnessed during the patient's 24-month follow-up. CONCLUSION: Intra-scleral fixation using iris retractors in the capsular bag for patients having suffered dislocation of IOL despite the attachment of a capsular hook because of zonular dialysis can be safely implemented.


Subject(s)
Lens Capsule, Crystalline/surgery , Lens Implantation, Intraocular/methods , Lens Subluxation/surgery , Sclera/surgery , Aged , Humans , Iris/surgery , Male , Surgical Flaps , Suture Techniques , Treatment Outcome
18.
Int Ophthalmol ; 38(3): 1111-1117, 2018 Jun.
Article in English | MEDLINE | ID: mdl-28534232

ABSTRACT

AIM: To evaluate the possible risk factors for posterior chamber intraocular lens dislocation either in-the-bag (ITB) dislocation or out-of-the-bag (OOTB) dislocation. METHODS: All subjects who sustained late intraocular lens dislocation from January 2011 until May 2014 and presented to the Nagasaki University Hospital were included in the study. This study is a retrospective evaluation of all cases of posterior chamber intraocular lens dislocation in this defined period. All cases had history of uncomplicated cataract surgery with implantation of posterior chamber intraocular lens. Patients with history of trauma (before cataract surgery) were excluded from the study. The main outcome measures of the study were evaluation of risk factors for dislocation of both groups and determination of the interval between cataract surgery and dislocation. RESULTS: Thirty-six eyes (69.23%) suffered ITB dislocation, and 16 eyes (30.77%) suffered OOTB dislocation. Intraocular lens dislocation was common in males (42 eyes = 80.77%) than females (10 eyes = 19.23%). Patients of ITB dislocation group were significantly older than OOTB dislocation group at the time of initial intraocular lens implantation and at the time of exchange surgery. CONCLUSION: The most prevalent risk factors in both groups were axial myopia in 18 eyes (34.61%), vitreoretinal surgery in 16 eyes (30.77%), and pseudoexfoliation in 13 eyes (25%) in all cases.


Subject(s)
Device Removal/methods , Foreign-Body Migration/epidemiology , Lenses, Intraocular/adverse effects , Posterior Eye Segment , Postoperative Complications , Visual Acuity , Aged , Female , Follow-Up Studies , Foreign-Body Migration/diagnosis , Foreign-Body Migration/surgery , Humans , Incidence , Japan/epidemiology , Male , Middle Aged , Reoperation , Retrospective Studies , Risk Factors
19.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-14013

ABSTRACT

PURPOSE: To evaluate the clinical stability and outcomes of 3-piece intraocular lens (IOL) transscleral fixation surgery using a modified injector. METHODS: We have modified and used the Sapphire unfolder injector system (Allergan(R), USA). This involved, cutting a slit longitudinally at the terminal part of the injector so that a thread could pass through it freely. After a conjunctival peritomy created at 2 and 8 o'clock, a long curved needle with double-armed 10-0 polypropylene is passed through the exposed sclera. Two pieces of suture are withdrawn through the 2.8 mm corneal incision and 1 suture (from 8 o'clock) is passed through the opening of the cartridge and then tied to the leading haptic. Next, the IOL was implanted with the cartridge and then inserted through the corneal incision site. The other suture (from 2 o'clock) is tied to the haptic on the opposite side and inserted. RESULTS: The study included 20 eyes of 20 patients with a mean age of 62.8 years at the initial visit. There were no complications, such as vitreous hemorrhage, retinal detachment, glaucoma, corneal edema, or iris injury. While the knot fixed to the leading haptic of IOL passed by the cartridge, there was no change of position. During the follow-up period, IOL dislocation did not occur and the corrected visual acuity and corneal astigmatism improved significantly. CONCLUSIONS: This technique is an effective procedure for minimizing entangled thread and corneal astigmatism.


Subject(s)
Humans , Aluminum Oxide , Astigmatism , Corneal Edema , Joint Dislocations , Follow-Up Studies , Glaucoma , Iris , Lenses, Intraocular , Needles , Polypropylenes , Retinal Detachment , Sclera , Sutures , Visual Acuity , Vitreous Hemorrhage
20.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-204052

ABSTRACT

PURPOSE: To report 2 cases of WIOL-CF(R) intraocular lens (IOL) (Gelmed International, Kamenne Zehrovice, Czech Republic) dislocation after neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy. CASE SUMMARY: A 78-year-old female was referred for IOL dislocation. She was implanted with WIOL-CF(R) IOL 18 months prior. Two months after WIOL-CF(R) implantation, she received Nd:YAG laser capsulotomy at a local clinic. Pars plana vitrectomy and transscleral fixation of IOL were performed. CONCLUSIONS: This is the first report of WIOL-CF(R) IOL dislocation after Nd:YAG laser capsulotomy in unvitrectomized eyes. When Nd:YAG laser capsulotomy is performed after WIOL-CF(R) IOL implantation, IOL dislocation should be considered even in unvitrectomized eyes.


Subject(s)
Aged , Female , Humans , Aluminum , Joint Dislocations , Lenses, Intraocular , Vitrectomy , Yttrium