Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 567
Filter
1.
Article in English | MEDLINE | ID: mdl-38992197

ABSTRACT

Ilio-femoral venous reconstruction has progressed from being only performed by a limited number of pioneers (often using equipment repurposed from other areas of interventional radiology) to a discrete subspecialty of endovascular practice with a dedicated range of tools and increasingly evolved techniques to secure optimal results. This review is intended to reflect the modern practice of ilio-femoral stenting in the acute and chronic settings, from initial patient assessment to completion of procedure and follow-up care.

2.
Article in English | MEDLINE | ID: mdl-38951251

ABSTRACT

Imaging plays an important role in the identification and assessment of clinically suspected venous pathology. The purpose of this article is to review the spectrum of image-based diagnostic tools used in the investigation of suspected deep vein disease, both obstructive (deep vein thrombosis and post-thrombotic vein changes) as well as insufficiency (e.g., compression syndromes and pelvic venous insufficiency). Additionally, specific imaging modalities are used for the treatment and during clinical follow-up. The use of duplex ultrasound, magnetic resonance venography, computed tomography venography and intravascular ultrasound as well as conventional venography will be discussed in this pictorial review.

3.
Article in English | MEDLINE | ID: mdl-38984675

ABSTRACT

A 32-year-old man, who was treated for T-cell lymphoma, presented in cardiac arrest. He had been treated for heart failure with reduced ejection fraction. Veno-arterial extracorporeal membrane oxygenation was initiated immediately. We diagnosed him as non-ST elevated myocardial infarction. Coronary angiography demonstrated the occlusion of the trifurcation in the proximal left anterior descending artery (LAD). We failed to advance the first guidewire into the distal LAD by angio-based conventional wiring. Intravascular ultrasonography (IVUS) of the proximal diagonal branch revealed two diaphragms separating the distal lumen without connection, which looks like lotus root-like appearance. We quickly penetrated the plaque using IVUS-based real-time 3D wiring using the tip detection method. The contrast injection via the microcatheter showed the distal diagonal branch (D2). After the balloon dilation in D2, IVUS image revealed a torn plaque between D2 and the distal LAD. Subsequently we advanced the guidewire to the distal LAD using IVUS-based real-time 3D wiring using the tip detection method through the tear of the plaque. Finally, we successfully performed the revascularization of LAD in a preferable procedure time. The patient recovered well and was discharged 39 days after cardiac arrest. This case highlights the efficacy of IVUS-based real-time 3D wiring using the tip detection method even in the emergent and challenging situation.

4.
Egypt Heart J ; 76(1): 83, 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963642

ABSTRACT

BACKGROUND: Over recent years, spontaneous coronary artery dissection (SCAD) has emerged as a no longer rare cause of acute coronary syndrome (ACS). On the other hand, coronary artery spasm (CAS) is the main cause of ischemic heart disease with non-obstructive coronary lesions. Clinical manifestations of both vary from stable angina to ACS or, rarely, sudden cardiac death. These entities may be underdiagnosed on a coronary angiography. CASE PRESENTATION: We report the case of a young woman presenting with acute chest pain and no coronary risk factors. Angiography revealed a focal subcritical stenosis of the right coronary artery. Coronary wiring resulted in diffuse and critical spasm. However, optical coherence tomography (OCT) and intravascular ultrasound (IVUS) showed extensive SCAD. She was therefore treated conservatively. On the fourth day, cardiac computed tomography angiography (CCTA) excluded disease progression, and then she was discharged on medical therapy. CONCLUSIONS: Combined IVI plays a vital role in providing accurate and detailed visualization of the coronary anatomy and thus allowing for more precise diagnosis, risk stratification, and treatment planning. CCTA can be considered a valuable tool in the noninvasive follow-up of SCAD.

5.
Transl Med UniSa ; 26(1): 38-45, 2024.
Article in English | MEDLINE | ID: mdl-38957729

ABSTRACT

The angiographic evidence of coronary multivessel disease (MVD) increases significantly the risk of recurrent ischemic events in patients with ST-segment elevation myocardial infarction (STEMI). Recent evidence suggests that a complete revascularization strategy should be considered the standard of care in these patients and performed for significant non-culprit lesions (NCLs) after careful assessment of the individual risk-benefit ratio. However, the optimal timing and the modality for the assessment of NCLs is not fully standardized. This brief review aims to summarise the management of MVD in patients with STEMI and to provide an overview of the principal techniques used to guide revascularisation in this high-risk clinical setting.

6.
Ann Vasc Surg ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38964443

ABSTRACT

OBJECTIVE: To present the value of intravascular ultrasound (IVUS) in diagnosis and treatment of complicated type B aortic dissection (TBD) with malperfusion (MP). Especially the value of IVUS regarding the treatment strategy, reoperation rate, acute kidney injury (AKI) and false lumen thrombosis (FLT) was investigated. METHODS: Retrospective analysis of 25 TBD cases with MP treated with endovascular therapy from April 2019 to August 2022. In 17 cases angiography & IVUS were applied during the operation (IVUS group) and in 8 cases angiography was used without IVUS (control group) for final intraoperative control. IVUS was used to assess the true lumen collapse and to decide if additional bare stenting was necessary or not. Details from patients' charts and documentation from surgeries were analyzed. The endovascular technique included thoracic endovascular aortic repair (TEVAR) with primary entry sealing and -if needed- bare stenting of the true lumen distal of the entry tears using the PETTICOAT (Provisional Extension To Induce Complete Attachment) technique. RESULTS: All patients presented with pain localized mostly (48%) in thorax and abdomen. In all patients the proximal entry tear of the dissection was covered using TEVAR. The PETTICOAT technique was applied in 13 cases (52%), whereas most combined procedures were applied in the IVUS group (12 compared to 1; p=0,02). A total of 3 patients (1 in the control group; 12,5% and 2 in the IVUS group; 11,8%) underwent a bowel resection. Totally 8 patients (32%) underwent a reoperation in aorta (3 during the hospital stay). There were no statistical differences between IVUS and control group regarding the preoperative findings, the reoperation rates and the postoperative complications. 5 patients died (4 during the hospital stay), 1 in control and 4 in IVUS group; p=0,53. The follow up included a clinical and a computed tomography angiography (CTA) examination. No statistically significant difference regarding occurrence and extension of FLT was observed between the two groups. CONCLUSIONS: The IVUS and control groups showed no difference in survival rates. The use of IVUS extended the indication for PETTICOAT technique with statistically significant difference. A milder form of AKI presented in the IVUS group compared to the control group. In addition, a stronger correlation between IVUS and the avoidance of an aorta reoperation was observed, though it did not reach statistical significance.

8.
Front Cardiovasc Med ; 11: 1395606, 2024.
Article in English | MEDLINE | ID: mdl-38883988

ABSTRACT

Background: Optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are superior to coronary angiography for guiding percutaneous coronary intervention (PCI). However, whether one technique is superior to the other is inconclusive. Methods: We searched PubMed, Embase, the Cochrane Library, and ClinicalTrials.gov from inception to November 2023 for randomized controlled trials (RCTs) comparing OCT and IVUS in patients undergoing PCI. RevMan 5.4 was used to pool outcomes with risk ratio (RR) as the effect measure. Results: Six RCTs (4,402 patients) were included in this meta-analysis. There was no significant difference between the OCT- and IVUS-guided PCI groups in the risk of major adverse cardiovascular events (RR 0.87, 95% CI: 0.65, 1.16; I2 = 0%) and cardiac mortality (RR 0.73, 95% CI: 0.24, 2.21; I2 = 0%). The results were consistent across the subgroups of the presence or absence of left main disease (P interaction >0.1). There were no significant differences between OCT and IVUS in the risk of target lesion revascularization (RR 0.78, 95% CI: 0.47, 1.30; I2 = 0%), target vessel revascularization (RR 1.06, 95% CI: 0.69, 1.62; I2 = 0%), target-vessel myocardial infarction (RR 0.79, 95% CI: 0.40, 1.53; I2 = 0%), stent thrombosis (RR 0.59, 95% CI: 0.12, 2.97; I2 = 0%), and all-cause mortality (RR 1.01, 95% CI: 0.53, 1.90; I2 = 0%). Conclusions: Our meta-analysis demonstrated similar clinical outcomes in OCT- and IVUS-guided PCI. New large-scale multicenter RCTs with long-term follow-up are required to confirm or refute our findings and provide more reliable results. Systematic Review Registration: PROSPERO, identifier, CRD42023486933.

9.
EJVES Vasc Forum ; 61: 141-144, 2024.
Article in English | MEDLINE | ID: mdl-38939115

ABSTRACT

Objective: Treatment of complex aortic aneurysms with the in situ laser fenestration (ISLF) technique involves implantation of a balloon expandable stent graft (bSG) in the created fenestration. Adequate expansion of this bSG is of importance both to achieve seal and to ensure target vessel stability. This experimental study assessed the expansion rate of different bSGs in the ISLF setting using intravascular ultrasound (IVUS). Methods: A commercially available aortic endograft was used to test the laser fenestration technique (Zenith Alpha, Cook Medical LLC, Bloomington, IN, USA). The ISLF was stented with the following bSGs: two Gore Viabahn VBX balloon expandable endoprostheses (WL Gore & Associates, Bloomington, IL, USA), three BeGraft Peripheral and three BeGraft Plus (Bentley InnoMed GmbH; Hechingen, Germany), and three Advanta V12 (Atrium, Hudson, NH, USA). The bSGs were expanded in three steps: (1) nominal, (2) rated burst pressure, and (3) dilation with a non-compliant balloon at 15 atmospheres. After each step, an IVUS assessment of the bSG minimum diameter and the area at the fenestration (FA) and in a fully expanded segment distal to the fenestration (SA) was performed. A mean of the three IVUS measurements was used as the value for comparison. An insufficient bSG expansion was defined as a mean of FA/SA of <0.8 (i.e., <80% expansion). Results: The VBX was the only bSG that could be expanded to its intended diameter (i.e., at least 80%) at nominal pressure. The BeGraft Peripheral and BeGraft Plus had the lowest degree of expansion after nominal and rated burst pressure. All bSGs that were tested reached a sufficient expansion degree after using a higher pressure balloon. Conclusion: In this ex vivo experiment, dilation up to nominal pressure showed satisfactory expansion only for the VBX. The consistency of the results when applied to the different types of stent grafts that were analysed reflects structural stent graft specific issues to consider when choosing the right device in cases of ISLF.

10.
Clin Cardiol ; 47(6): e24236, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38859725

ABSTRACT

Spontaneous coronary artery dissection (SCAD) is an increasingly recognized cause of myocardial infarction that most frequently affects younger women, making it an important cause of morbidity and mortality within these demographics. The evolution of intracoronary imaging, improved diagnosis with coronary angiography, and ongoing research efforts and attention via social media, has led to increasing recognition of this previously underdiagnosed condition. In this review, we provide a summary of the current body of knowledge, as well as focused updates on the pathogenesis of SCAD, insights on genetic susceptibility, contemporary diagnostic tools, and immediate, short- and long-term management.


Subject(s)
Coronary Angiography , Coronary Vessel Anomalies , Vascular Diseases , Humans , Coronary Vessel Anomalies/diagnosis , Vascular Diseases/congenital , Vascular Diseases/diagnosis , Risk Factors , Coronary Vessels/diagnostic imaging , Genetic Predisposition to Disease
11.
J Cardiovasc Dev Dis ; 11(6)2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38921677

ABSTRACT

BACKGROUND: Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have been shown to improve the clinical outcomes of percutaneous coronary interventions (PCIs) in selected subsets of patients. AIM: The aim was to investigate whether the use of OCT or IVUS during a PCI with rotational atherectomy (RA-PCI) will increase the odds for successful revascularization, defined as thrombolysis in myocardial infarction (TIMI) 3 flow. METHODS: Data were obtained from the national registry of PCIs (ORPKI) maintained by the Association of Cardiovascular Interventions (AISN) of the Polish Cardiac Society. The dataset includes PCIs spanning from January 2014 to December 2021. RESULTS: A total of 6522 RA-PCIs were analyzed, out of which 708 (10.9%) were guided by IVUS and 86 (1.3%) by OCT. The postprocedural TIMI 3 flow was achieved significantly more often in RA-PCIs guided by intravascular imaging (98.7% vs. 96.6%, p < 0.0001). Multivariable analysis revealed that using IVUS and OCT was independently associated with an increased chance of achieving postprocedural TIMI 3 flow by 67% (odds ratio (OR), 1.67; 95% confidence interval (CI): 1.40-1.99; p < 0.0001) and 66% (OR, 1.66; 95% CI: 1.09-2.54; p = 0.02), respectively. Other factors associated with successful revascularization were as follows: previous PCI (OR, 1.72; p < 0.0001) and coronary artery bypass grafting (OR, 1.09; p = 0.002), hypertension (OR, 1.14; p < 0.0001), fractional flow reserve assessment during angiogram (OR, 1.47; p < 0.0001), bifurcation PCI (OR, 3.06; p < 0.0001), and stent implantation (OR, 19.6, p < 0.0001). CONCLUSIONS: PCIs with rotational atherectomy guided by intravascular imaging modalities (IVUS or OCT) are associated with a higher procedural success rate compared to angio-guided procedures.

12.
Article in English | MEDLINE | ID: mdl-38932577

ABSTRACT

BACKGROUND: Coronary angiography and percutaneous coronary intervention (PCI) in patients with chronic kidney disease (CKD) is associated with increased risk of contrast induced nephropathy (CIN) and requirement for renal replacement therapy (RRT). OBJECTIVES: We aimed to evaluate our single center experience of ultra-low contrast PCI in patients with CKD and to characterize 1 year outcomes. METHODS: We performed a retrospective analysis of ultra-low contrast PCI at our institution between 2016 and 2022. Patients with CKD3b-5 (eGFR <45 mL/min/1.73m2), not on RRT who underwent ultra-low contrast PCI ( < 30 mL of contrast during PCI) were included. Primary outcomes included change in eGFR post-procedurally, and death, RRT requirement, and major adverse cardiac events (MACE) at 1 year follow-up. RESULTS: One hundred patients were included in the study. The median age was 67 years old and 28% were female. The median baseline eGFR was 21.5 mL/min/1.73m2 (IQR 14.08-32.0 mL/min/1.73m2). A median of 8.0 mL (IQR 0-15 mL) of contrast was used during PCI. Median contrast use to eGFR ratio was 0.37 (IQR 0-0.59). There was no significant difference between pre-and postprocedure eGFR (p = 0.84). At 1 year, 8% of patients died, 11% required RRT and 33% experienced MACE. The average time of RRT initiation was 7 months post-PCI. Forty-four patients were undergoing renal transplant evaluation, of which 17 (39%) received a transplant. CONCLUSIONS: In patients with advanced CKD, ultra-low contrast PCI is feasible and safe with minimal need for peri-procedural RRT. Moreover, ultra-low contrast PCI may allow for preservation of renal function in anticipation of renal transplantation.

13.
Article in English | MEDLINE | ID: mdl-38923152

ABSTRACT

BACKGROUND: Double kissing crush (DKC) and nano-crush (NC) techniques are frequently used, but the comparison for both techniques is still lacking. The goal of this multicenter study was to retrospectively assess the midterm clinical results of DKC and NC stenting in patients with complex bifurcation lesions (CBLs). METHODS: A total of 324 consecutive patients [male: 245 (75.6%), mean age: 60.73 ± 10.21 years] who underwent bifurcation percutaneous coronary intervention between January 2019 and May 2023 were included. The primary endpoint defined as the major cardiovascular events (MACE) included cardiac death, target vessel myocardial infarction (TVMI), or clinically driven target lesion revascularization (TLR). Inverse probability weighting (IPW) was performed to reduce treatment selection bias. This is the first report comparing the clinical outcomes of DKC and NC stenting in patients with CBL. RESULTS: The initial revascularization strategy was DKC in 216 (66.7%) cases and NC in 108 (33.3%) patients. SYNTAX scores [25.5 ± 6.73 vs. 23.32 ± 6.22, p = 0.005] were notably higher in the NC group than the DKC group. The procedure time (76.98 ± 25.1 vs. 57.5 ± 22.99 min, p = 0.001) was notably higher in the DKC group. The incidence of MACE (18.5 vs. 9.7%, p = 0.025), clinically driven TLR (14.8 vs. 6%, p = 0.009), and TVMI (10.2 vs. 4.2%, p = 0.048) were notably higher in the NC group than in the DKC group. The midterm MACE rate in the overall population notably differed between the NC group and the DKC group (adjusted HR (IPW): 2.712, [95% CI: 1.407-5.228], p = 0.003). CONCLUSION: In patients with CBLs, applying the DKC technique for bifurcation treatment had better ischemia-driven outcomes than the NC technique.

14.
Front Cardiovasc Med ; 11: 1374240, 2024.
Article in English | MEDLINE | ID: mdl-38798924

ABSTRACT

Anomalous origin of the coronary artery (AOCA) in coronary arteries represent a rare congenital variation, especially when three or more openings coexist, accompanied by conditions such as myocardial infarction, acute heart failure, and severe stenosis in three vessels, making it even rarer. This study reports a rare case of a patient admitted for the first time with acute myocardial infarction. Coronary angiography revealed four openings, along with the aforementioned rare conditions. Guided by intravascular ultrasound (IVUS), treatments were administered for different lesions in various vessels. IVUS confirmed a rare case with a 1 mm extremely short left main coronary artery and three openings. The two-year follow-up results for this patient are deemed satisfactory, indicating a favorable prognosis.

15.
16.
JACC Asia ; 4(5): 359-372, 2024 May.
Article in English | MEDLINE | ID: mdl-38765666

ABSTRACT

Background: The authors devised the tip detection (TD) method and developed AnteOwl WR intravascular ultrasound to standardize intravascular ultrasound-based 3-dimensional wiring for intraplaque tracking in chronic total occlusion (CTO)-percutaneous coronary intervention (PCI). The TD method also allowed antegrade dissection and re-entry (ADR). Combining TD-ADR with Conquest Pro 12 Sharpened Tip (CP12ST) wire, a new ADR wire with the strongest penetration force developed to date, enabled re-entry anywhere except calcification sites. Objectives: This study investigated the efficacy and feasibility of TD-ADR by comparison of procedural outcomes with Stingray-ADR in CTO-PCI. Methods: Twenty-seven consecutive CTO cases treated by TD-ADR with CP12ST wire between August 2021 and April 2023 and 27 consecutive CTO cases treated by Stingray-ADR with Conquest 8-20 (CP20) wire between March 2018 and July 2021 were retrospectively enrolled as the TD-ADR by CP12ST wire group and Stingray-ADR by CP20 wire group, respectively, from 4 facilities that could share technical information on these procedures. Results: The success rate of the ADR procedure was significantly improved (27 of 27 cases [100%] vs 18 of 27 cases [67%], respectively; P = 0.002) and total procedural time was significantly reduced (median procedural time: 145.0 [Q1-Q3: 118.0-240.0] minutes vs 185.0 [Q1-Q3: 159.5-248.0] minutes, respectively; P = 0.028) in the TD-ADR by CP12ST wire group compared to the Stingray-ADR by CP20 wire group. There were few in-hospital major adverse cardiac and cerebrovascular events or no complications in either group. Conclusions: TD-ADR by CP12ST wire can standardize highly accurate ADR in CTO-PCI.

18.
Cureus ; 16(3): e57164, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38681391

ABSTRACT

Purpose We investigated the impact of intravascular ultrasound guidance on reducing the incidence of contrast-induced acute kidney injury (CI-AKI) in patients undergoing percutaneous coronary intervention (PCI). Methods Ninety-nine patients were enrolled in this prospective cohort who were not randomly assigned to angiography-guided percutaneous coronary intervention or intravascular ultrasound-guided percutaneous coronary intervention. The patients were hospitalized at the Vietnam National Heart Institute - Bach Mai Hospital between 2019 and 2020. Acute kidney injury incidence during hospitalization was the primary endpoint. Results A total of 99 patients were divided into two groups: the intravascular ultrasound-guided group (33 participants) and the angiography-guided group (66 participants). The mean ± SD contrast volume of each group was 95.2 ± 37.1 mL and 133.0 ± 36.0 mL for the ultrasound-guided and angiography-guided groups, with P < 0.0001. Intravascular imaging-guided percutaneous coronary intervention (IVUS-guided PCI) was associated with reduced acute kidney injury incidence during hospitalization: 0.0% vs. 12.12% and P = 0.049. Conclusions Intravascular ultrasound is a safe imaging tool that guides percutaneous coronary intervention and significantly reduces the rate of acute kidney injury compared to angiography alone. Patients who have a high chance of experiencing acute kidney injury benefit from using intravascular ultrasound.

SELECTION OF CITATIONS
SEARCH DETAIL
...