Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 92
Filter
1.
Am J Clin Pathol ; 2024 May 06.
Article in English | MEDLINE | ID: mdl-38709595

ABSTRACT

OBJECTIVES: The aims of this study were to (1) establish the maximum allowable interference limits for hemolysis, lipemia, and icterus for chemistry analytes tested in body fluid samples and (2) assess the effectiveness of serial dilution to mitigate spectral interferences. METHODS: Residual body fluids from clinically ordered testing were mixed (<10% by volume) with stock solutions of interferent (spiked) and compared with a control spiked with an equal volume of 0.9% saline. The analytes were measured on the Roche cobas c501 instrument. Difference and percentage difference were calculated and compared with allowable total error limits. A subset of samples were serially diluted with 0.9% saline. Mean (SD) difference and percentage difference were calculated. RESULTS: The interference thresholds were lower than the package insert for lactate dehydrogenase, cholesterol, triglycerides, and total protein for hemolysis; amylase, cholesterol, and total protein for icterus; and albumin for lipemia. Only cholesterol and triglyceride results returned to baseline upon dilution of icteric samples. CONCLUSIONS: Interference thresholds in body fluids were lower than blood for 6 analytes. Diluting interferences that surpass these limits does not produce reliable results that are comparable to the baseline results before spiking in the interferent.

2.
J Vet Intern Med ; 38(2): 1043-1050, 2024.
Article in English | MEDLINE | ID: mdl-38361342

ABSTRACT

BACKGROUND: Total serum bilirubin concentration (TBIL) can provide useful information on several pathophysiological conditions in cats. Nevertheless, whether the variable severity classification of hyperbilirubinemia can reliably indicate certain disease processes or predict a biliary obstruction (BO) has not been investigated. HYPOTHESIS/OBJECTIVE: Determine if hyperbilirubinemia of variable severity can assist clinicians to identify BO, which often is considered a surgical emergency. ANIMALS: Two-hundred sixteen client-owned cats. METHODS: Data were retrospectively collected from all cats (January 2015-August 2022) with an increased TBIL (>0.58 mg/dL [>10 µmol/L]) presented to 3 referral centers in the United Kingdom (UK). Presenting clinical features and diagnostic outcomes were collected. The predictive ability of TBIL to indicate BO was evaluated by multivariable binary logistic regression modeling and receiver operating characteristic (ROC) curves. RESULTS: Median TBIL was 1.73 mg/dL (range, 0.59-26.15; 29.5 µmol/L; range, 10.1-447.1) with severity classification of hyperbilirubinemia categorized as mild (>0.58-2.92 mg/dL; >10-50 µmol/L; 68.1%), moderate (>2.92-5.85 mg/dL; >50-100 µmol/L; 17.6%), severe (>5.85-11.70 mg/dL; >100-200 µmol/L; 9.7%) and very severe (>11.70 mg/dL; >200 µmol/L; 4.6%). Biliary obstruction was present in 17 (7.9%) cats, all of which received recommendation for emergency surgery. Median TBIL in cats with BO (9.69 mg/dL; 165.7 µmol/L) differed significantly from those without obstruction (1.51 mg/dL; 25.8 µmol/L; P < .01). The optimal TBIL cut-off to discriminate between cats with and without BO was ≥3.86 mg/dL (≥66 µmol/L) with a sensitivity of 94.1% and specificity of 82.4%. Using multivariable logistic regression, as age increased, the odds of BO increased significantly (odds ratio, 1.20; 95% confidence interval, 1.01-1.42; P = .04). CONCLUSIONS AND CLINICAL IMPORTANCE: As part of a thorough clinical assessment, the severity classification of hyperbilirubinemia has the potential to predict the likelihood of a BO and to discriminate between cats that may or may not require surgery for BO at a suggested cut-off of ≥3.86 mg/dL (≥66 µmol/L). Alongside TBIL, age is also useful when assessing for the likelihood of BO in a cat presented with hyperbilirubinemia.


Subject(s)
Cat Diseases , Cholestasis , Animals , Cats , Bilirubin , Cat Diseases/diagnosis , Cholestasis/veterinary , Hyperbilirubinemia/diagnosis , Hyperbilirubinemia/veterinary , Retrospective Studies , United Kingdom
3.
Indian J Pediatr ; 2024 Jan 12.
Article in English | MEDLINE | ID: mdl-38214829

ABSTRACT

OBJECTIVES: To compare the performance of Modified Kramer's and Kramer's methods in terms of agreement with total serum bilirubin (TSB). METHODS: This cross-sectional study was done in Level-III neonatal unit in New Delhi. Visibly jaundiced neonates born at ≥35 wk of gestation were enrolled and examined by (i) conventional Kramer's, (ii) Modified Kramer's in artificial (MK-A) and (iii) natural daylight (MK-N), and finally sampled for estimation of TSB by point-of-care spectrophotometry. The primary outcomes were agreement of Kramer's and Modified Kramer's with TSB and accuracy in terms of proportion of bilirubin estimates lying within ±2 mg/dL of TSB; secondary outcome was agreement of MK-A and MK-N with TSB. RESULTS: A total of 144 neonates with median gestation of 37 wk and mean birth weight of 2788 g were enrolled. Bland Altman analysis between Kramer's and TSB yielded mean difference of 1.7 mg/dL, 95% limits of agreement (LOA) -3.1 to 6.6 mg/dL. For Modified Kramer's and TSB, mean difference was -0.02 mg/dL, 95% LOA -4.7 to 4.7 mg/dL under artificial light; 0.02 mg/dL, 95% LOA -4.2 to 4.2 mg/dL under natural daylight. MK-N had highest proportion of bilirubin estimates lying within ±2 mg/dL of TSB (68.7%) as compared to MK-A (59.7%) [OR, 1.77; 95% CI, 1.09 to 2.86] and Kramer's (45.8%) [OR, 1.65; 95% CI, 1.27 to 2.15]. CONCLUSIONS: Though all the three methods had poor agreement with TSB, Modified Kramer's method when performed in natural light had reasonable accuracy, however limited clinical utility, in evaluation of clinical jaundice.

6.
Biochem Med (Zagreb) ; 33(2): 020702, 2023 Jun 15.
Article in English | MEDLINE | ID: mdl-37324113

ABSTRACT

Introduction: Icterus, if not detected, can affect the validity of results delivered by clinical laboratories, leading to erroneous results. This study aims to define bilirubin interference for some biochemical analytes and compare it with the manufacturer's data. Material and methods: Serum pools prepared with outpatients' samples were spiked with increasing bilirubin concentration (Merck, reference14370, Darmstadt, Germany) up to 513 µmol/L in order to evaluate the bias for the following biochemical analytes: creatinine (CREA), creatine kinase (CK), cholesterol (CHOL), gamma-glutamyltransferase (GGT), high-density lipoprotein cholesterol (HDL), and total protein (TP). For each analyte, six pools of different concentrations were prepared. Measurements were made employing Cobas 8000 analyser c702-502, Roche Diagnostics (Mannheim, Germany). This study employed a study procedure defined by the Spanish Society of Laboratory Medicine. Results: Obtained bilirubin concentrations producing a negative interference were 103 µmol/L for CHOL, 205 µmol/L for TP and 410 µmol/L for CK, but only for CK values less than 100 U/L. Bilirubin concentrations lower than 513 µmol/L do not produce interference for HDL and GGT. Finally, for the studied bilirubin concentrations, there is no interference for CREA higher than 80 µmol/L. Conclusion: Icterus interferences have been defined for each analyte, observing differences compared to data provided by the manufacturer. The evidence indicates that each laboratory should evaluate icteric interferences to ensure the high quality of the delivered results, thus benefiting patient care.


Subject(s)
Cholesterol , Jaundice , Humans , Serum , Bilirubin , Creatinine , Creatine Kinase
8.
Vet Sci ; 10(6)2023 Jun 15.
Article in English | MEDLINE | ID: mdl-37368781

ABSTRACT

Although many studies have been conducted on the use of median and transverse incisions in various surgeries in the field of human medicine, related studies in veterinary medicine are lacking. This study aimed to present treatment options for dogs requiring cholecystectomy by reporting the pros and cons of 121 cholecystectomies performed via transverse incision at our hospital over 10 years. In most included cases, nonelective cholecystectomy was performed in an unstable emergency situation. The perioperative mortality rate was 23.14%, which was not significantly different from that of cholecystectomy performed via the conventional midline approach. However, the overall operation time (46.24 ± 6.13 min; range 35-65 min) was shortened by securing an adequate surgical field of view. The transverse incision approach facilitates fast and accurate surgery without increasing the fatality rate in small-breed dogs, in whom securing an adequate surgical field of view is difficult. Thus, transverse incision should be actively considered in dogs undergoing cholecystectomy due to emergency conditions, such as bile leakage or biliary tract obstruction, since prolonged anesthesia can be burdensome. This study may improve cholecystectomy outcomes in small-breed dogs with difficult-to-secure surgical fields.

9.
Clin Chem Lab Med ; 61(6): 1035-1045, 2023 05 25.
Article in English | MEDLINE | ID: mdl-36635939

ABSTRACT

OBJECTIVES: Hemolysis, icterus, and lipemia (HIL) are common sources of endogenous interference in clinical laboratory testing. Defining the threshold of interference for immunoassays enables appropriate reporting of their results when they are affected by HIL. METHODS: Pools of residual patient serum samples were spiked with a known amount of interferent to create samples with varying concentrations of hemolysate, bilirubin, and Intralipid that mimicked the effects of endogenous HIL. Samples were analysed on the Alinity i analyser (Abbott Diagnostics) for more than 25 immunoassays. The average recovery relative to the non-spiked sample was calculated for each interference level and was compared to a predefined allowable bias. RESULTS: C-peptide, estradiol, serum folate, free T4, homocysteine, insulin, and vitamin B12 were found to be affected by hemolysis, at hemoglobin concentrations between 0.3 to 20 g/L. Immunoassays for BNP, estradiol, free T3, and homocysteine were affected by icterus at conjugated bilirubin concentrations between 50 to 1,044 µmol/L. BNP, serum folate, and homocysteine were affected by Intralipid with measured triglyceride concentrations between 0.8 to 10 mmol/L. Lastly, serological immunoassays for HIV and hepatitis A, B and C were also affected by interferences. CONCLUSIONS: Immunoassays are impacted by varying degrees of HIL interference. Some measurands, in the presence of interference, are affected in a manner not previously indicated. The data presented herein provide an independent evaluation of HIL thresholds and will be of aid to resource-limited clinical laboratories that are unable to internally verify endogenous interferences when implementing the Alinity i analyser.


Subject(s)
Hyperlipidemias , Jaundice , Humans , Hemolysis , Hyperlipidemias/diagnosis , Jaundice/diagnosis , Immunoassay/methods , Bilirubin , Estradiol , Folic Acid
11.
Scand J Clin Lab Invest ; 83(1): 64-67, 2023 02.
Article in English | MEDLINE | ID: mdl-36534490

ABSTRACT

Prolonged icterus is an important and common problem in neonatology and accurate determination of the different bilirubin species, including differentiation between delta-bilirubin and mono- and di-conjugated bilirubin, is useful for diagnostic purposes. However, most bilirubin measurements routinely performed in the clinical laboratory are hampered by the lack of separation of the four bilirubin fractions (unconjugated bilirubin, mono-conjugated bilirubin, di-conjugated bilirubin, and delta-bilirubin). Herein, we propose a high-performance liquid chromatography-based method, independent of commercially available standards or reliable molar absorption coefficients, for the determination of bilirubin fractions in blood samples from icteric patients. The method is a robust and reliable candidate for a semi-automatized setup for measuring the various bilirubin fractions in a specialized laboratory handling samples from clinics with expertise in biliary disease.


Subject(s)
Bilirubin , Gallbladder Diseases , Humans , Chromatography, High Pressure Liquid/methods
12.
Cureus ; 14(11): e30963, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36465219

ABSTRACT

Leptospirosis is a zoonosis with clinical manifestations caused by a pathogenic bacterium of the genus Leptospira. A high index of suspicion is required to make the diagnosis. The unusual constellation of symptoms makes the diagnosis of leptospirosis challenging and requires a comprehensive approach while treating the patient. This case illustrates the potential for severe complications of untreated leptospirosis and underlines the importance of a holistic approach to the diagnosis and treatment of patients with perplexing clinical presentations.

13.
Vnitr Lek ; 68(E-8): 18-22, 2022.
Article in English | MEDLINE | ID: mdl-36575062

ABSTRACT

In this case report is discussed the diagnosis of papillary carcinoma in the case of a patient in whose age the occurrence of the disease is very rare. The patient underwent a series of non-invasive and invasive examinations, the results of which eventually led to a surgical solution of the suspected lesion (Wipples procedure). Histological examination of the resection confirmed mixed type ampular adenocarcinoma. In the context of this finding, the results of the examination, their information value, interpretation and mutual interaction are discussed. In the postoperative period, the patient suffered from gastrointestinal bleeding, subileum and poor postoperative healing. After hospitalization, the patient was transferred to oncology care and indicated for genetic testing.


Subject(s)
Adenocarcinoma , Adenomatous Polyposis Coli , Ampulla of Vater , Common Bile Duct Neoplasms , Jaundice , Humans , Ampulla of Vater/pathology , Ampulla of Vater/surgery , Adenomatous Polyposis Coli/surgery , Common Bile Duct Neoplasms/diagnosis , Common Bile Duct Neoplasms/pathology , Common Bile Duct Neoplasms/surgery , Adenocarcinoma/complications , Adenocarcinoma/diagnosis , Jaundice/pathology
14.
Cureus ; 14(7): e27543, 2022 Jul.
Article in English | MEDLINE | ID: mdl-36060325

ABSTRACT

Laparoscopic cholecystectomy (LC) is one of the most commonly performed general surgical procedures worldwide. Common bile duct (CBD) injuries are occasionally seen after this procedure and manifest as biliary peritonitis or bile collection; however, retroperitoneal bile leak is an extremely rare phenomenon manifesting as yellow discoloration of the abdominal wall, and a few cases are reported in the English literature. In this article, we describe one case of retroperitoneal bile leak that manifested as flank discoloration and its management.

15.
Clin Appl Thromb Hemost ; 28: 10760296221118483, 2022.
Article in English | MEDLINE | ID: mdl-35924377

ABSTRACT

Objective: Evaluate the technical performance of the pre-analytical hemolysis-icterus-lipemia (HIL) check module on the ACL-TOP-750. Methods: 8433 routine coagulation samples were evaluated for HIL, the presence of clotting and low sample volume by both visual inspection and the pre-analytical HIL check module on the ACL-TOP-750. Results: 7726 samples were in agreement with both methods and 707 were not consistent. 356 samples with low volume were identified by visual inspection and 920 by the instrument (2.7 mL threshold). Visual inspection identified 56 lipemic samples while 13 of those with moderate or high lipemia were identified by the instrument. Visual inspection identified 47 hemolyzed samples while 7 with moderate or high hemolysis were identified by the instrument. Both visual inspection and the instrument identified 36 icteric samples. For triglyceride concentration and bilirubin concentration, there was good correlation between the ACL-TOP-750 and the DXC800 biochemistry analyzer. Among 30 samples with varying amounts of clotting, 27 were discovered by visual inspection and 3 were discovered by the instrument. Conclusion: The pre-analytical check module on the ACL-TOP-750 improved the detection rate of samples below the target 2.7 mL volume, and the accuracy in detection of HIL. However, the automated method could not replace visual assessment of clotting in samples.


Subject(s)
Hyperlipidemias , Jaundice , Blood Coagulation Tests/methods , Hemolysis , Hemostasis , Humans
16.
Animals (Basel) ; 12(12)2022 Jun 20.
Article in English | MEDLINE | ID: mdl-35739925

ABSTRACT

Yellow lamb disease is an infrequent disease in sheep for which there is scant literature, and that has been reported in the US, Australia, New Zealand, South Africa and Europe, although anecdotal evidence indicates that it may have also been diagnosed in South America. The disease is produced by some strains of Clostridium perfringens type A that produce unusually high levels of alpha- toxin. Because C. perfringens type A is ubiquitous and is found in the intestine of most clinically healthy sheep, diagnosis of yellow lamb disease is challenging and requires quantitating the amount of this microorganism present in feces and/or intestinal content. Clinically, yellow lamb disease is characterized by depression, anemia, icterus and hemoglobinuria. Occasionally, sudden death may occur. Gross findings include generalized icterus, red urine in the bladder, enlarged, pale, and friable spleen, enlarged liver with an acinar pattern, and dark, swollen kidneys. Microscopically, yellow lamb disease is characterized by centrilobular necrosis of the liver, hemoglobinuria-associated acute tubular injury, splenic congestion, pulmonary congestion and edema. Although there are no vaccines specifically designed to prevent yellow lamb disease, several vaccines against the different types of C. perfringens may afford at least some level of protection against yellow lamb disease.

17.
Clin Chim Acta ; 531: 254-260, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35421398

ABSTRACT

BACKGROUND: Serum quality is an important factor in the pre-analytical phase of laboratory analysis. Visual inspection of serum quality (including recognition of hemolysis, icterus, and lipemia) is widely used in clinical laboratories but is time-consuming, subjective, and prone to errors. METHODS: Deep learning models were trained using a dataset of 16,427 centrifuged blood images with known serum indices values (including hemolytic index, icteric index, and lipemic index) and their performance was evaluated by five-fold cross-validation. Models were developed for recognizing qualified, unqualified and image-interfered samples, predicting serum indices values, and finally composed into a deep learning-based system for the automatic assessment of serum quality. RESULTS: The area under the receiver operating characteristic curve (AUC) of the developed model for recognizing qualified, unqualified and image-interfered samples was 0.987, 0.983, and 0.999 respectively. As for subclassification of hemolysis, icterus, and lipemia, the AUCs were 0.989, 0.996, and 0.993. For serum indices and total bilirubin predictions, the Pearson's correlation coefficients (PCCs) of the developed model were 0.840, 0.963, 0.854, and 0.953 respectively. Moreover, 30.8% of serum indices tests were deemed unnecessary due to the preliminary application of the deep learning-based system. CONCLUSIONS: The deep learning-based system is suitable for the assessment of serum quality and holds the potential to be used as an accurate, efficient, and rarely interfered solution in clinical laboratories.


Subject(s)
Deep Learning , Hyperlipidemias , Jaundice , Hemolysis , Humans , Pre-Analytical Phase
18.
F1000Res ; 11: 1534, 2022.
Article in English | MEDLINE | ID: mdl-38025296

ABSTRACT

Background: Neonatal hyperbilirubinemia is one of the most common conditions for neonate inpatients. Indonesia faces a major challenge in which different guidelines regarding the management of this condition were present. This study aimed to compare the existing guidelines regarding prevention, diagnosis, treatment and monitoring in order to create the best recommendation for a new hyperbilirubinemia guideline in Indonesia. Methods: Through an earlier survey regarding adherence to the neonatal hyperbilirubinemia guideline, we identified that three main guidelines are being used in Indonesia. These were developed by the Indonesian Pediatric Society (IPS), the Ministry of Health (MoH), and World Health Organization (WHO). In this study, we compared factors such as prevention, monitoring, methods for identifying, risk factors in the development of neonatal jaundice, risk factors that increase brain damage, and intervention treatment threshold in the existing guidelines to determine the best recommendations for a new guideline. Results: The MoH and WHO guidelines allow screening and treatment of hyperbilirubinemia based on visual examination (VE) only. Compared with the MoH and WHO guidelines, risk assessment is comprehensively discussed in the IPS guideline. The MoH guideline recommends further examination of an icteric baby to ensure that the mother has enough milk without measuring the bilirubin level. The MoH guideline recommends referring the baby when it looks yellow on the soles and palms. The WHO and IPS guidelines recommend combining VE with an objective measurement of transcutaneous or serum bilirubin. The threshold to begin phototherapy in the WHO guideline is lower than the IPS guideline while the exchange transfusion threshold in both guidelines are comparably equal. Conclusions: The MoH guideline is outdated. MoH and IPS guidelines are causing differences in approaches to the management hyperbilirubinemia. A new, uniform guideline is required.


Subject(s)
Hyperbilirubinemia, Neonatal , Jaundice, Neonatal , Infant, Newborn , Humans , Child , Indonesia , Hyperbilirubinemia, Neonatal/diagnosis , Hyperbilirubinemia, Neonatal/therapy , Jaundice, Neonatal/therapy , Phototherapy/adverse effects , Bilirubin
19.
Dig Dis ; 40(3): 362-369, 2022.
Article in English | MEDLINE | ID: mdl-34015787

ABSTRACT

BACKGROUND: Jaundice is a common clinical finding in clinical practice of hepatologists and general practitioners. It occurs when serum bilirubin levels exceed 3 mg/dL. SUMMARY: In this review, we summarize the pathophysiological mechanism of jaundice, clinical approach to the patient with jaundice, and laboratory and imaging techniques. Clinical presentation of jaundice manifests through yellow skin and sclera coloration. Evaluation of every patient includes detailed medical history and examination. In the laboratory, evaluation of enzymes of hepatic inflammation as well as cholestatic enzymes with serum bilirubin must be included. Additional laboratory analysis and imaging modalities are needed in order to differentiate jaundice etiology. Moreover, imaging is available and needed in further evaluation, and treatment is dependent on the underlying cause. KEY MESSAGES: In this review, we will outline the pathophysiological mechanism of jaundice, clinical approach to the patient with jaundice, and diagnostic and treatment approach to these patients.


Subject(s)
Cholestasis , General Practitioners , Jaundice , Bilirubin , Cholestasis/etiology , Humans , Jaundice/diagnosis , Jaundice/etiology , Jaundice/therapy , Liver Function Tests
20.
Clin Chem Lab Med ; 60(1): 66-73, 2022 01 26.
Article in English | MEDLINE | ID: mdl-34670030

ABSTRACT

OBJECTIVES: Serum indices included in clinical chemistry instruments are widely used by laboratories to assess the quality of samples. Instruments that report quantitative results allow an evaluation of their diagnostic performance in a similar way to other biochemical tests. The Spanish Society of Laboratory Medicine (SEQC-ML) launched a monthly External Quality program of serum indices in 2018 using three lyophilized materials of simultaneous annual distribution. We present the results of the first three years of the program. METHODS: The use of four different quality control materials with different concentrations in three alternate months allows an annual evaluation of the participant's accuracy. Assigned values are established by consensus among homogeneous groups, considering necessary at least 10 participants for a comparison at instrument level. The average percentage difference results per instrument allow the assessment of bias among groups. RESULTS: The imprecision of the three indices ranges between 3 and 9%, with no major differences among instruments. Significant differences were observed in all indices among instruments with more than 10 participants (Roche Cobas, Abbott Architect, Abbott Alinity and Siemens Advia). The 90th percentile of the distribution of percentage differences was used as the analytical performance specification (APS). An improvement in performance was observed in the first three years of the program, probably due to the learning curve effect. In 2020, APS of 7.8, 12.2 and 9.7% were proposed for hemolytic, icteric and lipemic indices, respectively. CONCLUSIONS: Serum indices have a great impact on the quality and the reliability of laboratory test results. Participation in proficiency testing programs for serum indices is helpful to encourage harmonization among providers and laboratories.


Subject(s)
Laboratories , Laboratory Proficiency Testing , Humans , Quality Control , Reproducibility of Results , Serum
SELECTION OF CITATIONS
SEARCH DETAIL
...