1.
Healthcare (Basel) ; 12(9)2024 May 03.
Article in English | MEDLINE | ID: mdl-38727497

ABSTRACT

Pulse oximetry is a non-invasive, cost-effective, and generally reliable instrument measuring pulse rate and peripheral oxygen saturation (SpO2). However, these measurements can be affected by the patient's internal or external factors, including the type of pulse oximeter device (POD). (1) This study's objective was to identify potential environmental factors that may impact the measurements taken by three PODs. (2) Methods: A descriptive-analytical cross-sectional study was designed. The patients' SpO2 levels were measured using a standard monitor and two PODs owned by the professionals. The measurements were taken on the patients' fingers. Concurrently, we evaluated the surrounding environmental conditions, encompassing temperature, humidity, illuminance, and noise. (3) Results: This study involved 288 adult participants in the sample. For each 20-decibel increment in noise, there was a reduction in SpO2 by an average of 1%, whereas for every additional degree of ambient temperature, SpO2 decreased by an average of 2% (4) Conclusions: Significant correlations between SpO2 and age, as well as with noise and ambient temperature, were observed. No significant differences between oxygen saturation and lighting or humidity were observed. This study was prospectively registered with the Clinical Research Ethics Committee of Gran Canaria at the Dr. Negrín University Hospital, with protocol code 2019-247-1, and approved on 24 May 2019.

2.
Luminescence ; 39(5): e4763, 2024 May.
Article in English | MEDLINE | ID: mdl-38761029

ABSTRACT

The development of optical optics for low-location road lighting is a challenging problem in providing high luminance and uniformity of illumination and meeting many other specific requirements. This study proposes an optical design method of low-location illumination based on an asymmetric double freeform surface lens. The ray emitted from the light source is refracted and reflected through the different surface types to the corresponding area of the receiving surface. In the design example, the road has dual-side mounted luminaires and a width of 6 m, and a height of 0.8 m. Simulation results indicate that, compared with conventional high-pole streetlights, the luminance uniformity had increased from 0.60 to 0.66, the illuminance uniformity had improved from 0.75 to 0.86, and the glare had been reduced.


Subject(s)
Lighting , Surface Properties , Light , Equipment Design
3.
World J Urol ; 42(1): 298, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38709327

ABSTRACT

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Subject(s)
Equipment Design , Kidney , Lighting , Ureteroscopes , Models, Anatomic , Humans
4.
BMC Med Educ ; 24(1): 415, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627740

ABSTRACT

BACKGROUND: Suture knotting is the basis of surgical skills. In the process of surgical skills learning, the surrounding environment, especially the light, will affect the efficiency of learning. This study investigated the effect of optical environment on the learning of stitching and knotting skills. METHODS: A total of 44 medical students were randomly divided into four groups and participated in the study of suture knotting in four different optical environments. During the process, we assess objective pressure level by testing salivary amylase activity Likert scale and objective structured clinical examination (OSCE) was used to estimate the subjective psychological state and overall skill mastery in surgical suturing respectively. RESULTS: Under high illumination conditions (700 lx), the salivary amylase activity of the high color temperature group (6000 K) was significantly higher than that of the low color temperature group (4000 K) (p < 0.0001). Similarly, under low illumination (300 lx), the salivary amylase activity of the high color temperature group was also significantly higher than that of the low color temperature group (p < 0.05). The student under high illumination conditions (700 lx) and the low color temperature (6000 K) have an autonomy score between 37-45, which is significantly higher compared to the other three groups (p < 0.0001). Group 2 has an average OSCE score of 95.09, which were significantly higher than those of the other three groups (p < 0.05). CONCLUSION: High illumination combined with low color temperature is considered as the optimal training conditions, promoting trainees' optimism, reducing stress levels, and enhancing learning efficiency. These results highlight the pivotal role of light environment in improving the quality and efficiency of surgical skills training.


Subject(s)
Learning , Physical Examination , Humans , Amylases , Clinical Competence , Suture Techniques/education
5.
Parasitol Res ; 123(4): 194, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38656453

ABSTRACT

Light-Emitting Diodes (LEDs) have been effective light sources in attracting Anopheles mosquitoes, but the broad-spectrum white light, even with a wide-ranging application in lighting, have not been evaluated yet. In this study, the white light was field evaluated against the green one in the light trapping of anopheline mosquitoes by using two non-suction Silva traps and two CDC-type suction light traps. Anopheline mosquitoes were captured for two 21-night periods of collecting (2022 and 2023). In the first period, two LEDs were used per Silva trap, but three were used in the second one to increase the luminance/illuminance at traps. A CDC-type suction light trap equipped with an incandescent lamp was used in 2022 and a CDC-type suction light trap equipped with a 6 V-white light (higher luminance/illuminance) in 2023. A total of eight species and 3,289 specimens were captured in both periods. The most frequent species were Anopheles triannulatus s.l., An. goeldii, An. evansae and An. argyritarsis. In 2022, white LEDs were less attractive to anopheline mosquitoes than the other light sources, but without statistical difference among treatments (F = 2.703; P = 0.0752; df = 2). In 2023, even with an increased luminance/illuminance at traps, no statistical difference was found between the two LED-baited Silva traps (F = 6.690; P = 0.0024; df = 2), but rather between the 6 V-white-baited CDC-type suction light trap and green-baited Silva traps. Due to some drawbacks and the lower abundance of individuals caught by using white LEDs, the narrow-banded green LEDs is preferable to white ones for attracting anophelines.


Subject(s)
Anopheles , Light , Mosquito Control , Animals , Anopheles/physiology , Anopheles/radiation effects , Mosquito Control/methods , Mosquito Control/instrumentation
6.
World J Urol ; 42(1): 188, 2024 Mar 23.
Article in English | MEDLINE | ID: mdl-38520528

ABSTRACT

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Subject(s)
Lighting , Ureteroscopes , Humans , Equipment Design , Urologists , Disposable Equipment , Ureteroscopy
7.
Heliyon ; 10(6): e27485, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38524564

ABSTRACT

Projectors are common display devices in the educational setting. However, dim projector lightbulbs or well-lit classrooms may cause blurriness in the projected image. To determine the optimal projection light under different ambient light conditions, the conjoint effects of projection illuminance and ambient illuminance on the legibility of projection images indoors were investigated. Participants (N = 96) were randomly assigned to one of six indoor ambient light conditions (0, 40, 80, 120, 160, and 200 lx) and performed a visual search task under several projection illuminance conditions (200, 250, 300, 350, and 400 lx). The accuracy and correct response time on the task were collected to evaluate the participants' visual performance to represent legibility. The optimal projection illuminance (high visual accuracy and fast reaction) was 400 lx (944 ANSI lumen) under all ambient light conditions. To avoid low legibility (accuracy<0.6) and maintain acceptable legibility (accuracy>0.7), the projection illuminance should be increased as the indoor ambient light increases.

8.
J. optom. (Internet) ; 17(1)Jan.-March. 2024. tab, graf
Article in English | IBECS | ID: ibc-229112

ABSTRACT

Purpose To describe the performance of the Actiwatch Spectrum Plus (Philips, Respironics) for determining real world indoor and outdoor environments and physical activity in children. Methods Children wore the device while performing 10 different activities, ranging from sedentary to vigorous physical-activity, and under different indoor and outdoor conditions. Repeated measures ANOVA was implemented via mixed effects modeling to determine illuminance (lux) and physical activity (counts per 15 s, CP15) across conditions. Receiver operator characteristics (ROC) analysis assessed the accuracy to detect indoor versus outdoor settings. Results Illuminance was found to be statistically different across indoor (793 ± 348 lux) and outdoor (4,413 ± 518 lux) conditions (P<.0001), with excellent diagnostic accuracy to detect indoor versus outdoor settings (Area under the ROC Curve, AUC 0.94); 1088 lux was identified as the optimal threshold for outdoor illuminance (sensitivity: 93.0%; specificity: 85.0%). Using published activity ranges, we found that when children were sitting, 94% of the physical-activity readings were classified as sedentary or light. When children were walking, 88% of readings were classified as light, and when children were running, 77% of readings were classified as moderate or vigorous. Conclusion The Actiwatch Spectrum Plus performed well during real world activities in children, showing excellent diagnostic accuracy at 1088 lux as a threshold to detect indoor versus outdoor environments and in categorizing physical activity. (AU)


Subject(s)
Humans , Child , Lighting , Photophobia , Exercise , Luminescent Measurements/methods , Remote Sensors , Luminescence
9.
Animal ; 18(3): 101092, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38412781

ABSTRACT

The effect of light intensity has been explored in relation to endocrine functions and reproduction in pigs, but effects on health and behaviour are scarcely documented. The objective of this study was to evaluate the effects of different light intensities on behaviour, health and growth of growing-finishing pigs. An experiment was conducted on a commercial farm equipped with light-emitting diode-based luminaires creating four light intensity treatments: low (45 lux), medium (198 lux), high (968 lux) and spatial gradient of intensity (from 71 lux to 330 lux). Per treatment, 112 pigs were studied in two batches of eight pens. Once every two weeks behaviours such as exploration, positive and negative social interactions, play and abnormal behaviours were observed. Health issues were assessed weekly and included biting lesions, skin lesions, leg and respiratory disorders. The average daily gain over the experiment was calculated and after slaughter carcasses were inspected. Generalised linear mixed models were used for the analysis of behaviours, binary health scores, carcass abnormalities, ordinal logistic regression for multilevel health scores, and linear mixed models for average daily gain. Interactions between intensity and week were found for some behaviours (i.e., exploration, negative social interactions and abnormal behaviour) and health issues (i.e., tear stains, conjunctivitis, body lesions, bursitis and tail lesions). However, none of the treatments consistently outperformed another one. Light treatments did not affect pig growth and carcass abnormalities. These variable results support studies suggesting that pigs are adaptable to light intensities, and inconsistencies over weeks might have been caused by environmental factors that could not be controlled in a commercial farm setting. To conclude, tested light intensities had no clear effects on pig behaviour, health and growth.


Subject(s)
Bites and Stings , Swine Diseases , Swine , Animals , Animal Welfare , Aggression , Bites and Stings/veterinary , Logistic Models , Health Behavior , Swine Diseases/pathology
10.
J Optom ; 17(1): 100483, 2024.
Article in English | MEDLINE | ID: mdl-37797567

ABSTRACT

PURPOSE: To describe the performance of the Actiwatch Spectrum Plus (Philips, Respironics) for determining real world indoor and outdoor environments and physical activity in children. METHODS: Children wore the device while performing 10 different activities, ranging from sedentary to vigorous physical-activity, and under different indoor and outdoor conditions. Repeated measures ANOVA was implemented via mixed effects modeling to determine illuminance (lux) and physical activity (counts per 15 s, CP15) across conditions. Receiver operator characteristics (ROC) analysis assessed the accuracy to detect indoor versus outdoor settings. RESULTS: Illuminance was found to be statistically different across indoor (793 ± 348 lux) and outdoor (4,413 ± 518 lux) conditions (P<.0001), with excellent diagnostic accuracy to detect indoor versus outdoor settings (Area under the ROC Curve, AUC 0.94); 1088 lux was identified as the optimal threshold for outdoor illuminance (sensitivity: 93.0%; specificity: 85.0%). Using published activity ranges, we found that when children were sitting, 94% of the physical-activity readings were classified as sedentary or light. When children were walking, 88% of readings were classified as light, and when children were running, 77% of readings were classified as moderate or vigorous. CONCLUSION: The Actiwatch Spectrum Plus performed well during real world activities in children, showing excellent diagnostic accuracy at 1088 lux as a threshold to detect indoor versus outdoor environments and in categorizing physical activity.


Subject(s)
Exercise , Light , Child , Humans
11.
J Sleep Res ; 33(4): e14113, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38097530

ABSTRACT

Light can influence many psychophysiological functions beyond vision, including alertness, circadian rhythm, and sleep, namely the non-image forming (NIF) effects of light. Melanopic equivalent daylight illuminance (mel-EDI) is currently recommended as the predictor of the NIF effects of light. Although light dose is also critical for entraining and regulating circadian cycle, it is still unknown whether relatively low mel-EDI light exposure for prolonged duration in the evening would affect pre-sleep arousal and subsequent sleep. In all, 18 healthy college students (10 females, mean [standard deviation] age 21.67 [2.03] years) underwent 2 experimental nights with a 1 week interval in a simulated bedroom environment. During experimental nights, participants were either exposed to high or low mel-EDI light (73 versus 38 lx mel-EDI, 90 versus 87 photopic lx at eye level, 150 photopic lx at table level) for 3.5 h before regular bedtime, and their sleep was monitored by polysomnography. Subjective sleepiness, mood, and resting-state electroencephalography during light exposure were also investigated. Results showed no significant differences in sleep structure and sleep quality between the two light conditions, whereas 3.5 h of exposure to high versus low mel-EDI light induced marginally higher physiological arousal in terms of a lower delta but higher beta power density before sleep, as well as a lower delta power density during sleep. Moreover, participants felt happier before sleep under exposure to high versus low mel-EDI light. These findings together with the current literature suggest that evening prolonged relatively low mel-EDI light exposure may mildly increase arousal before and during sleep but affected sleep structure less.


Subject(s)
Arousal , Circadian Rhythm , Electroencephalography , Light , Polysomnography , Sleep , Humans , Female , Arousal/physiology , Young Adult , Male , Sleep/physiology , Circadian Rhythm/physiology , Affect/physiology , Adult , Sleep Quality
12.
Ophthalmic Physiol Opt ; 44(1): 191-198, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37950504

ABSTRACT

Peripheral refraction is believed to be involved in the development of myopia. The aim of this study was to compare the relative peripheral refraction (RPR) at four different levels of illuminance, ranging from photopic conditions to complete darkness, using an open-field autorefraction method. The RPR was calculated for each eccentricity by subtracting central from peripheral autorefraction measurements. The study included 114 myopic eyes from 114 subjects (mean age of 21.81 ± 1.91 years) and the mean difference in RPR between scotopic and photopic conditions (0 and 300 lux, respectively) was +0.32 D at 30° temporal and +0.37 D at 30° in the nasal visual field (NVF). Statistically significant differences were observed between 0 and 300 lux at 30° in the temporal visual field and at 30° and 20° in the NVF. Our results revealed a significant increase in relative peripheral hyperopia with increasing visual field eccentricity along the horizontal visual field in myopic eyes of young adults. Furthermore, this relative peripheral hyperopia increased as illumination decreased. These findings suggest that an increase in peripheral illuminance may protect against myopic eye growth.


Subject(s)
Hyperopia , Myopia , Young Adult , Humans , Adult , Refraction, Ocular , Vision Tests , Eye , Myopia/diagnosis
13.
Luminescence ; 2023 Dec 26.
Article in English | MEDLINE | ID: mdl-38147880

ABSTRACT

In light-emitting diode (LED) illumination (e.g., LED maritime lighting for ships), creating a uniform light environment for optical systems is an important challenge. In this study, we present a high-power collimating system based on Fresnel lenses, which allows high-brightness LED illumination in the earlier-mentioned remote distance. The work presented in this article focuses on improving the power, compacting the optical structure, and promoting the brightness of the spot. To prove the claims, the system with a total power of 1 kW is designed. The system consists of a 27 W LED array, a freeform surface lens array, and a confocal Fresnel lens array. In comparison with the traditional optical system, the optical structure shortens from 390 to 120 mm, and the divergent angle decreases from 3° to 2 ° $$ {}^{{}^{\circ}} $$ . Meanwhile, the illuminance of the system is obtained as high as 230 lx at the near field of 200 m and 3.0 lx at the far field of 1.5 nautical miles. This new method provides a practical and effective way to solve the problem of low power, insufficient illuminance, and long optical structure for LED array illumination, which is suitable for remote illumination and guidance of ships.

14.
Sensors (Basel) ; 23(22)2023 Nov 11.
Article in English | MEDLINE | ID: mdl-38005501

ABSTRACT

Coal gangue image recognition is a critical technology for achieving automatic separation in coal processing, characterized by its rapid, environmentally friendly, and energy-saving nature. However, the response characteristics of coal and gangue vary greatly under different illuminance conditions, which poses challenges to the stability of feature extraction and recognition, especially when strict illuminance requirements are necessary. This leads to fluctuating coal gangue recognition accuracy in industrial environments. To address these issues and improve the accuracy and stability of image recognition under variable illuminance conditions, we propose a novel coal gangue recognition method based on laser speckle images. Firstly, we studied the inter-class separability and intra-class compactness of the collected laser speckle images of coal and gangue by extracting gray and texture features from the laser speckle images, and analyzed the performance of laser speckle images in representing the differences between coal and gangue minerals. Subsequently, coal gangue recognition was achieved using an SVM classifier based on the extracted features from the laser speckle images. The fusion feature approach achieved a recognition accuracy of 94.4%, providing further evidence of the feasibility of this method. Lastly, we conducted a comparative experiment between natural images and laser speckle images for coal gangue recognition using the same features. The average accuracy of coal gangue laser speckle image recognition under various lighting conditions is 96.7%, with a standard deviation of the recognition accuracy of 1.7%. This significantly surpasses the recognition accuracy obtained from natural coal and gangue images. The results showed that the proposed laser speckle image features can facilitate more stable coal gangue recognition with illumination factors, providing a new, reliable method for achieving accurate classification of coal and gangue in the industrial environment of mines.

15.
J Sleep Res ; : e14085, 2023 Oct 30.
Article in English | MEDLINE | ID: mdl-37904313

ABSTRACT

Light triggers numerous non-image-forming, or non-visual, biological effects. The brain correlates of these non-image-forming effects have been investigated, notably using magnetic resonance imaging and short light exposures varying in irradiance and spectral quality. However, it is not clear whether non-image-forming responses estimation may be biased by having light in sequential blocks, for example, through a potential carryover effect of one light onto the next. We reasoned that pupil light reflex was an easy readout of one of the non-image-forming effects of light that could be used to address this issue. We characterised the sustained pupil light reflex in 13-16 healthy young individuals under short light exposures during three distinct cognitive processes (executive, emotional and attentional). Light conditions pseudo-randomly alternated between monochromatic orange light (0.16 melanopic equivalent daylight illuminance lux) and polychromatic blue-enriched white light of three different levels (37, 92, 190 melanopic equivalent daylight illuminance lux). As expected, higher melanopic irradiance was associated with larger sustained pupil light reflex in each cognitive domain. This result was stable over the light sequence under higher melanopic irradiance levels compared with lower ones. Exploratory frequency-domain analyses further revealed that sustained pupil light reflex was more variable under lower melanopic irradiance levels. Importantly, sustained pupil light reflex varied across tasks independently of the light condition, pointing to a potential impact of light history and/or cognitive context on sustained pupil light reflex. Together, our results emphasise that the distinct contribution and adaptation of the different retinal photoreceptors influence the non-image-forming effects of light and therefore potentially their brain correlates.

16.
Animals (Basel) ; 13(20)2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37893981

ABSTRACT

Measuring animal activity and its evolution in real time is useful for animal welfare assessment. In addition, illuminance and noise level are two factors that can improve our understanding of animal activity. This study aims to establish relationships between animal activity as measured by passive infrared sensors, and both illuminance and noise level on a conventional weaned piglet farm. First, regression models were applied, and then cosine models with three harmonics were developed using least squares with a Generalized Reduced Gradient Nonlinear method. Finally, all the models were validated. Linear models showed positive correlations, with values between 0.40 and 0.56. Cosine models drew clear patterns of daily animal activity, illuminance and noise level with two peaks, one in the morning and one in the afternoon, coinciding with human activity inside the building, with a preference for inactivity at night-time and around midday. Cosine model fitting revealed strong correlations, both in the measurement and validation periods, for animal activity (R = 0.97 and 0.92), illuminance (R = 0.95 and 0.91) and noise level (R = 0.99 and 0.92). The developed models could be easily implemented in animal welfare monitoring systems and could provide useful information about animal activity through continuous monitoring of illuminance or noise levels.

17.
J Safety Res ; 86: 253-261, 2023 09.
Article in English | MEDLINE | ID: mdl-37718053

ABSTRACT

INTRODUCTION: Nighttime crashes account for 74% of pedestrian fatalities in the United States, and reduced visibility is a significant cause of nighttime pedestrian crashes. Maintaining sufficient and uniform roadway lighting is an effective countermeasure to improve pedestrian visibility and prevent nighttime pedestrian crashes and injuries. Previous studies have not quantified the safety effects of roadway photometric patterns (i.e., average lighting level and uniformity) on nighttime pedestrian crashes on roadway segments. METHOD: This study investigated the association between two roadway photometric criteria (horizontal illuminance mean representing average lighting level and horizontal illuminance standard deviation representing lighting uniformity) and nighttime pedestrian crash occurrence in Florida roadway segments. The matched case-control method was used to decouple the confounding effects between the illuminance mean and standard deviation. Statistically-significant crash modification factors (CMFs) were developed to quantify the safety effects of the mean and standard deviation of horizontal illuminance on nighttime pedestrian crashes. RESULTS: The results show that if the average lighting level on a roadway segment is increased from a low illuminance mean (<0.2 foot-candle [fc]) to a medium illuminance mean [0.2 fc, 0.5 fc], a medium-high illuminance mean (0.5 fc, 1.0 fc], and a high illuminance mean (>1.0 fc), the relative likelihood of nighttime pedestrian crashes on midblock segments in Florida tends to be reduced by 77.5% (CMF = 0.225), 81.2% (CMF = 0.188), and 85.5% (CMF = 0.145), respectively. PRACTICAL APPLICATIONS: A poor uniformity (illuminance standard deviation ≥ 0.52 fc) is likely to increase the relative likelihood of nighttime pedestrian crashes on midblock segments in Florida by 80.3% (CMF = 1.803) compared to good uniformity (illuminance standard deviation < 0.52 fc).


Subject(s)
Erythema Nodosum , Pedestrians , Humans , Accidents, Traffic/prevention & control , Lighting
18.
Life (Basel) ; 13(9)2023 Sep 12.
Article in English | MEDLINE | ID: mdl-37763304

ABSTRACT

BACKGROUND: Amblyopia is associated with unbalanced suppression between the two eyes. Existing clinical measures of suppression, such as the Worth 4 Dot test, provide qualitative information about suppression but cannot precisely quantify it. The Synoptophore, a well-established instrument in binocular vision clinics, has historically been used to gauge suppression qualitatively as well but has the capability to quantify suppression. We extended the capability of the Synoptophore through the development of a systematic protocol of illumination manipulation to quantify suppression in amblyopia. METHODS: Twenty-six previously treated adult amblyopes underwent our protocol on the Synoptophore to measure the illumination balance needed to obtain fusion responses. Separately, these same amblyopes were tested with Worth 4 Dot as it is classically performed in the United States, utilizing different test distances and room illuminations to qualify the suppression response. RESULTS: Smaller, more central targets revealed larger magnitudes of suppression for both the Synoptophore and Worth 4 Dot tests (Synoptophore: χ25,26 = 25.538, p < 0.001; Worth 4 Dot: χ23,26 = 39.020, p < 0.001). There was a significant correlation between the two tests for depth of suppression measurements (rΤ > 0.345, p < 0.036), with more sensitivity measured by the Synoptophore, as suppression could be graded on a quantitative scale. Strabismic amblyopes demonstrated more suppression than non-strabismic amblyopes (z > 2.410, p < 0.016). Additionally, depth of suppression was correlated with interocular difference in both visual acuity (rΤ = 0.604, p < 0.001) and stereoacuity (rΤ = 0.488, p = 0.001). CONCLUSIONS: We extended the utility of the Synoptophore by measuring its illuminance outputs and developing a suppression testing protocol that compared favorably with Worth 4 Dot (clinic standard) while improving upon the latter through more sensitive quantification of suppression.

19.
Sensors (Basel) ; 23(18)2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37765756

ABSTRACT

This paper analyzes the light-scattering standards currently used for calibration (verification) and systematic research in photo and spectrophotometry tools. The application specificities in studying the diffuse reflected and transmitted light during biomedical CCD photometry are considered. The advantages of a new class of photometers with non-spherical reflectors as ellipsoids of revolution truncated along the focal planes with the internal mirror surface are presented. The ellipsoid first focal plane is combined with the surface of the under-study media, and the second is optically coupled to the CCD image sensor plane. The principles of zone analysis of spatial distribution reproduced in photometric images on a CCD sensor are substantiated. The illuminance levels of photometric image areas in reflected and transmitted light from the thickness of the standard for the wavelength of laser radiation of 650 nm of different power was experimentally investigated. Polynomial dependences were obtained, and regression coefficients of the illuminance of the external and middle rings in photometric images for the reflected and transmitted light on the laser power were determined.

20.
Clocks Sleep ; 5(3): 476-498, 2023 Aug 29.
Article in English | MEDLINE | ID: mdl-37754350

ABSTRACT

The visual and non-visual effectiveness of light is often determined by measuring the spectrally weighed irradiance on the corneal plane. This is typically achieved using spectral irradiance or illuminance measurements, captured in a hemispheric (2π) geometry with a diffuser. However, the human binocular field of view (FOV) is not a perfect hemisphere, as it is occluded both upward and downward. Previous research on FOV-restricted measurements is limited, leaving the error from using hemispheric measurements for non-visual quantities undefined. In our study, we tackled this issue by designing and 3D printing FOV occlusions as attachments to spectral measurement devices. We took measurements with and without the occlusion in various laboratory (light from different directions) and real-world lighting situations (light typically from above). Our findings reveal a reduction of visual and melanopic values due to the FOV occlusion. These ranged from negligible to more than 60% in realistic scenarios. Interestingly, the reduction was consistent for both visual and melanopic parameters, as the distribution of light in the FOV was generally spectrally homogeneous. An exception occurred in a specific artificial laboratory situation, where the melanopic daylight (D65) efficacy ratio changed by more than a factor of 2 solely because of the FOV occlusion. Additionally, we observed that head orientation had a marked effect on all quantities measured. In conclusion, our results highlight the potential for substantial errors when solely relying on vertical, hemispheric measurements in experiments and non-visual lighting design projects. We encourage the (additional) use of FOV occlusion in eye-level measurements for typical viewing directions, and we are providing open-source 3D-print files to facilitate this practice.