1.
Imaging Sci Dent ; 53(2): 109-115, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37405203

ABSTRACT

Purpose: The aim of this study was to evaluate changes in the trabecular bone through texture analysis and compare the texture analysis characteristics of different areas in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: Cone-beam computed tomographic images of 16 patients diagnosed with MRONJ were used. In sagittal images, 3 regions were chosen: active osteonecrosis (AO); intermediate tissue (IT), which presented a zone of apparently healthy tissue adjacent to the AO area; and healthy bone tissue (HT) (control area). Texture analysis was performed evaluating 7 parameters: secondary angular momentum, contrast, correlation, sum of squares, inverse moment of difference, sum of entropies, and entropy. Data were analyzed using the Kruskal-Wallis test with a significance level of 5%. Results: Comparing the areas of AO, IT, and HT, significant differences (P<0.05) were observed. The IT and AO area images showed higher values for parameters such as contrast, entropy, and secondary angular momentum than the HT area, indicating greater disorder in these tissues. Conclusion: Through texture analysis, changes in the bone pattern could be observed in areas of osteonecrosis. The texture analysis demonstrated that areas visually identified and classified as IT still had necrotic tissue, thereby increasing the accuracy of delimiting the real extension of MRONJ.

2.
ABC., imagem cardiovasc ; 36(1): e371, abr. 2023. ilus
Article in Portuguese | LILACS | ID: biblio-1513116

ABSTRACT

Fundamento: A avaliação da área valvar mitral por meio da reconstrução multiplano na ecocardiografia tridimensional é restrita a softwares específicos e à experiência dos ecocardiografistas. Eles precisam selecionar manualmente o frame do vídeo que contenha a área de abertura máxima da valva mitral, dimensão fundamental para a identificação de estenose mitral. Objetivo: Automatizar o processo de determinação da área de abertura máxima da valva mitral, por meio da aplicação de Processamento Digital de Imagens (PDI) em exames de ecocardiograma, desenvolvendo um algoritmo aberto com leitura de vídeo no formato avi. Método: Este estudo piloto observacional transversal foi realizado com vinte e cinco exames diferentes de ecocardiograma, sendo quinze com abertura normal e dez com estenose mitral reumática. Todos os exames foram realizados e disponibilizados por dois especialistas, com autorização do Comitê de Ética em Pesquisa, que utilizaram dois modelos de aparelhos ecocardiográficos: Vivid E95 (GE Healthcare) e Epiq 7 (Philips), com sondas multiplanares transesofágicas. Todos os vídeos em formato avi foram submetidos ao PDI através da técnica de segmentação de imagens. Resultados: As medidas obtidas manualmente por ecocardiografistas experientes e os valores calculados pelo sistema desenvolvido foram comparados utilizando o diagrama de Bland-Altman. Observou-se maior concordância entre valores no intervalo de 0,4 a 2,7 cm². Conclusão: Foi possível determinar automaticamente a área de máxima abertura das valvas mitrais, tanto para os casos advindos da GE quanto da Philips, utilizando apenas um vídeo como dado de entrada. O algoritmo demonstrou economizar tempo nas medições quando comparado com a mensuração habitual. (AU)


Background: The evaluation of mitral valve area through multiplanar reconstruction in 3-dimensional echocardiography is restricted to specific software and to the experience of echocardiographers. They need to manually select the video frame that contains the maximum mitral valve opening area, as this dimension is fundamental to identification of mitral stenosis. Objective: To automate the process of determining the maximum mitral valve opening area, through the application of digital image processing (DIP) in echocardiography tests, developing an open algorithm with video reading in avi format. Method: This cross-sectional observational pilot study was conducted with 25 different echocardiography exams, 15 with normal aperture and 10 with rheumatic mitral stenosis. With the authorization of the Research Ethics Committee, all exams were performed and made available by 2 specialists who used 2 models of echocardiographic devices: Vivid E95 (GE Healthcare) and Epiq 7 (Philips), with multiplanar transesophageal probes. All videos in avi format were submitted to DIP using the image segmentation technique. Results: The measurements obtained manually by experienced echocardiographers and the values calculated by the developed system were compared using a Bland-Altman diagram. There was greater agreement between values in the range from 0.4 to 2.7 cm². Conclusion: It was possible to automatically determine the maximum mitral valve opening area, for cases from both GE and Philips, using only 1 video as input data. The algorithm has been demonstrated to save time on measurements when compared to the usual method. (AU)


Subject(s)
Humans , Heart Valve Diseases/mortality , Mitral Valve/physiopathology , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/etiology , Image Processing, Computer-Assisted/methods , Doxorubicin/radiation effects , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Transcatheter Aortic Valve Replacement/methods , Isoproterenol/radiation effects , Mitral Valve/surgery
3.
Medisur ; 20(2)abr. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1405901

ABSTRACT

RESUMEN Fundamento: el procesamiento de imágenes es clave en la planificación de tratamientos de radioterapia con haces externos. En su ejecución pueden ocurrir errores humanos y fallos de equipos, que conllevan, entre otros efectos, a interpretaciones erróneas de imágenes diagnósticas, errores de contorneo de blancos, sobredosis a tejidos sanos o subdosis a tejidos tumorales, lo cual significa poner en riesgo a los pacientes sometidos a estas prácticas. Objetivo: caracterizar los riesgos asociados a los factores tecnológicos y humanos relacionados con el procesamiento de imágenes que pueden afectar a los pacientes sometidos a tratamientos de radioterapia con haces externos. Métodos: como base de estudio se empleó la práctica de radioterapia de intensidad modulada. Para caracterizar los iniciadores y las medidas de defensa relacionados con este procesamiento, se emplearon modelos de riesgo basados en análisis de modos y efectos de fallo y matriz de riesgo de la práctica de referencia, que fueron procesados con el software SECURE-MR-FMEA. Resultados: los análisis de sensibilidad sobre los modelos de radioterapia de intensidad modulada mostraron los efectos sobre el riesgo de los fallos asociados al procesamiento de imágenes. Conclusiones: se confirmó la importancia de aplicar el análisis de riesgo en el procesamiento de imágenes para elevar la seguridad de los pacientes durante los tratamientos de radioterapia con haces externos.


ABSTRACT Background: image processing is the key in planning external beam radiotherapy treatments. In its execution, human errors and equipment failures can occur, which lead, among other effects, to erroneous interpretations of diagnostic images, target contouring errors, overdose of healthy tissues or underdose of tumor tissues, which means putting patients at risk patients subjected to these practices. Objective: to characterize the risks associated with technological and human factors related to image processing that can affect patients undergoing radiotherapy treatments with external beams. Methods: intensity modulated radiotherapy was used as the basis of the study. To characterize the initiators and defense measures related to this processing, risk models were used based on analysis of failure modes and effects and the risk matrix of the reference practice, which were processed with the SECURE-MR-FMEA software. Results: the sensitivity analyzes on the intensity-modulated radiotherapy models showed the effects on the risk of failures associated with image processing. Conclusions: the importance of applying risk analysis in image processing to increase patient safety during external beam radiotherapy treatments was confirmed.

4.
Medisur ; 20(2)abr. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1405903

ABSTRACT

RESUMEN Fundamento: en los laboratorios de microbiología, la identificación y conteo de microorganismos es un procedimiento habitual. Aunque existen en el mercado equipos que posibilitan su realización de manera automática o semiautomática, son muy costosos, por lo cual esta tarea, difícil e irritante para los ojos, la siguen realizando los expertos de manera tradicional mediante la observación de las muestras en los microscopios, con la consiguiente variabilidad entre ellos. Objetivo: proponer un nuevo método para el conteo de bacterias y levaduras en imágenes digitales, bajo diferentes magnificaciones, tomadas a bioproductos de origen microbiano obtenidos por fermentación. Métodos: el sensor empleado para la toma de imágenes de las muestras fue una cámara digital modelo HDCE-X, con un sensor CMOS de ½", con una resolución de 2592 píxeles por 1944 píxeles (5 Mp). Se emplearon dos tipos de magnificaciones: magnificación 40x (PL40, 0.65 apertura numérica and 0.17 de distancia de trabajo) y magnificación 100x (HI plan 100/1.25 con inmersión de aceite). El método propuesto se basa en técnicas de procesamiento digital de imágenes, utilizando herramientas como la detección de contornos, operaciones morfológicas y análisis estadístico, y fue desarrollado en lenguaje Python con empleo de la biblioteca OpenCV. Resultados: la detección y conteo de bacterias se logró con una exactitud y precisión aceptable, en ambos casos por encima de 0,95; no en el caso de las levaduras cuya exactitud y precisión fueron menores, alrededor de 0,78 y 0,86 respectivamente. Se proponen flujos de trabajo basados en técnicas de procesamiento digital de imágenes, fundamentalmente en detección de contornos, operaciones morfológicas y análisis estadístico. Conclusiones: el método posee una efectividad aceptable para el contexto y depende de las características que presenten las imágenes.


ABSTRACT Background: In microbiology laboratories, the identification and counting of microorganisms is a common procedure; and although there is a variety of equipment on the market that possibility to carry out these processes automatically or semi-automatically, it is usually expensive to many laboratories. These are some of the reasons why this arduous and difficult task is still performed in many laboratories by experts in the traditional way, through the observation of samples in microscope, consuming a great time and having variations in the results between experts. Objective: The present work aims to propose a new method for counting bacteria and yeasts in digital images, taken under different magnifications, of microbial bioproducts obtained by fermentation. Methods: The sensor used to take images of the samples was a digital camera model HDCE-X, with a ½" CMOS sensor, with a resolution of 2592 pixels by 1944 pixels (5 Mp). Two types of magnifications were used: 40x magnification (PL40, 0.65 numerical aperture and 0.17 working distance) and 100x magnification (HI plan 100/1.25 with oil immersion). The proposed method is based on digital image processing technics, using tools as contour detection, morphological operations and statistical analysis, and was developed in Python language using the OpenCV library. The work also presents a comparison with the results obtained using ImageJ software for the same purpose. Results: the detection and count of bacteria was achieved with an acceptable accuracy and precision, in both cases above 0.95; not in the case of yeasts whose accuracy and precision was lower, around 0.78 for accuracy and 0.86 for precision. Workflows based on digital image processing techniques are proposed, using tools as contour detection, morphological operations and statistical analysis. Conclusions: the method has an acceptable effectiveness for the context and depends on the characteristics presented by the images.

5.
Medisur ; 20(2)abr. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1405905

ABSTRACT

RESUMEN Fundamento: la segmentación del hígado utilizando datos de tomografía computarizada es el primer paso para el diagnóstico de enfermedades hepáticas. Actualmente la segmentación de estructuras y órganos, basado en imágenes, que se realiza en los hospitales del país, dista de tener los niveles de precisión que se obtienen de los modernos sistemas 3D, por lo que se requiere buscar alternativas viables utilizando el PDI sobre ordenador. Objetivo: determinar una variante eficaz y eficiente desde el punto de vista computacional en condiciones de rutina hospitalaria, para la segmentación de imágenes hepáticas con fines clínicos. Métodos: se compararon dos métodos modernos de segmentación (Graph Cut y EM/MPM) aplicándolos sobre imágenes de tomografía de hígado. Se realizó un análisis evaluativo y estadístico de los resultados obtenidos en la segmentación de las imágenes a partir de los coeficientes de Dice, Vinet y Jaccard. Resultados: con el método Graph Cut, en todos los casos, se segmentó la región deseada, incluso cuando la calidad de las imágenes era baja, se observó gran similitud entre la imagen segmentada y la máscara de referencia. El nivel de detalles visuales es bueno y la reproducción de bordes permanece fiel a la máscara de referencia. La segmentación de las imágenes por el método de EM/MPM, no siempre fue satisfactoria. Conclusiones: el método de segmentación Graph Cut obtuvo mayor precisión para segmentar imágenes de hígado.


ABSTRACT Background: liver segmentation using computed tomography data is the first step for the diagnosis of liver diseases. Currently, the segmentation of structures and organs, based on images, which is carried out in the country's hospitals, is far from having the levels of precision obtained from modern 3D systems, it is necessary to search for viable alternatives using the PDI on a computer. Objective: to determine an effective and efficient variant from the computational point of view in routine hospital conditions, for the segmentation of liver images for clinical purposes. Methods: Two modern segmentation methods (Graph Cut and EM/MPM) were compared by applying them to liver tomography images. An evaluative and statistical analysis of the results obtained in the segmentation of the images from the Dice, Vinet and Jaccard coefficients was carried out. Results: with the Graph Cut method, in all cases, the desired region was segmented, even when the quality of the images was low, great similarity was observed between the segmented image and the reference mask. The level of visual detail is good, and edge reproduction remains true to the reference skin. Image segmentation by the EM/MPM method was not always satisfactory. Conclusions: the Graph Cut segmentation method obtained greater precision to segment liver images.

6.
Restor Dent Endod ; 47(1): e8, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35284330

ABSTRACT

Objectives: The aim of this study was to compare the color change of the Giomer resin composite (Beautifil-Bulk) by using photographs obtained with a smartphone (iPhone 6S) associated with Adobe Photoshop software (digital method), with the spectrophotometric method (Vita Easyshade) after immersion in different pigment solutions. Materials and Methods: Twenty resin composite samples with a diameter of 15.0 mm and thickness of 1.0 mm were confectioned in A2 color (n = 5). Photographs and initial color readings were performed with a smartphone and spectrophotometer, respectively. Then, samples were randomly divided and subjected to cycles of immersion in distilled water (control), açai, Coke, and tomato sauce, 3 times a day, 20 minutes for 7 days. Later, new photographs and color readings were taken. Results: The analysis (2-way analysis of variance, Holm-Sidak, p < 0.05) demonstrated no statistical difference (p < 0.005) between the methods in all groups. Similar color changes were observed for all pigment solutions when using the spectrophotometric method. For the digital method, all color changes were clinically unacceptable, with distilled water and tomato sauce similar to each other and with statistical differences (p < 0.005) for Coke and açai. Conclusions: Only the tomato sauce produced a color change above the acceptability threshold using both methods of color assessment. The spectrophotometric and digital methods produce different patterns of color change. According to our results, the spectrophotometric method is more recommended in color change assessment.

7.
Radiol Bras ; 54(3): 155-164, 2021.
Article in English | MEDLINE | ID: mdl-34108762

ABSTRACT

OBJECTIVE: To evaluate the degree of similarity between manual and semiautomatic segmentation of soft-tissue sarcomas on magnetic resonance imaging (MRI). MATERIALS AND METHODS: This was a retrospective study of 15 MRI examinations of patients with histopathologically confirmed soft-tissue sarcomas acquired before therapeutic intervention. Manual and semiautomatic segmentations were performed by three radiologists, working independently, using the software 3D Slicer. The Dice similarity coefficient (DSC) and the Hausdorff distance were calculated in order to evaluate the similarity between manual and semiautomatic segmentation. To compare the two modalities in terms of the tumor volumes obtained, we also calculated descriptive statistics and intraclass correlation coefficients (ICCs). RESULTS: In the comparison between manual and semiautomatic segmentation, the DSC values ranged from 0.871 to 0.973. The comparison of the volumes segmented by the two modalities resulted in ICCs between 0.9927 and 0.9990. The DSC values ranged from 0.849 to 0.979 for intraobserver variability and from 0.741 to 0.972 for interobserver variability. There was no significant difference between the semiautomatic and manual modalities in terms of the segmentation times (p > 0.05). CONCLUSION: There appears to be a high degree of similarity between manual and semiautomatic segmentation, with no significant difference between the two modalities in terms of the time required for segmentation.


OBJETIVO: Verificar a similaridade entre as segmentações manual e semiautomática de sarcomas de tecidos moles na ressonância magnética (RM) e a similaridade interobservador e intraobservador entre as segmentações manuais. MATERIAIS E MÉTODOS: Estudo retrospectivo que incluiu 15 exames de RM de pacientes com diagnóstico de sarcoma de tecidos moles realizados antes de intervenções terapêuticas. As segmentações manual e semiautomática foram realizadas por três radiologistas utilizando o software 3D Slicer. O coeficiente de similaridade Dice (CSD) e a distância de Hausdorff foram utilizados para avaliar a similaridade das segmentações. Análise estatística descritiva e coeficiente de correlação intraclasse (CCI) foram realizados para comparar volumes tumorais. RESULTADOS: A comparação dos métodos manual e semiautomático obteve valores de CSD entre 0,871 e 0,973. A comparação dos volumes segmentados pelos dois métodos de segmentação mostrou CCI entre 0,9927 e 0,9990. As análises intraobservador e interobservador obtiveram valores de CSD, respectivamente, de 0,849 a 0,979 e de 0,741 a 0,972. Não houve diferença significativa entre os tempos de segmentação dos métodos semiautomático e manual (p > 0,05). CONCLUSÃO: Houve alta similaridade entre as segmentações de sarcomas de tecidos moles obtidas pelos métodos manual e semiautomático, sem diferença significativa para o tempo despendido para as segmentações.

8.
Radiol. bras ; Radiol. bras;54(3): 155-164, May-June 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1250656

ABSTRACT

Abstract Objective: To evaluate the degree of similarity between manual and semiautomatic segmentation of soft-tissue sarcomas on magnetic resonance imaging (MRI). Materials and Methods: This was a retrospective study of 15 MRI examinations of patients with histopathologically confirmed soft-tissue sarcomas acquired before therapeutic intervention. Manual and semiautomatic segmentations were performed by three radiologists, working independently, using the software 3D Slicer. The Dice similarity coefficient (DSC) and the Hausdorff distance were calculated in order to evaluate the similarity between manual and semiautomatic segmentation. To compare the two modalities in terms of the tumor volumes obtained, we also calculated descriptive statistics and intraclass correlation coefficients (ICCs). Results: In the comparison between manual and semiautomatic segmentation, the DSC values ranged from 0.871 to 0.973. The comparison of the volumes segmented by the two modalities resulted in ICCs between 0.9927 and 0.9990. The DSC values ranged from 0.849 to 0.979 for intraobserver variability and from 0.741 to 0.972 for interobserver variability. There was no significant difference between the semiautomatic and manual modalities in terms of the segmentation times (p > 0.05). Conclusion: There appears to be a high degree of similarity between manual and semiautomatic segmentation, with no significant difference between the two modalities in terms of the time required for segmentation.


Resumo Objetivo: Verificar a similaridade entre as segmentações manual e semiautomática de sarcomas de tecidos moles na ressonância magnética (RM) e a similaridade interobservador e intraobservador entre as segmentações manuais. Materiais e Métodos: Estudo retrospectivo que incluiu 15 exames de RM de pacientes com diagnóstico de sarcoma de tecidos moles realizados antes de intervenções terapêuticas. As segmentações manual e semiautomática foram realizadas por três radiologistas utilizando o software 3D Slicer. O coeficiente de similaridade Dice (CSD) e a distância de Hausdorff foram utilizados para avaliar a similaridade das segmentações. Análise estatística descritiva e coeficiente de correlação intraclasse (CCI) foram realizados para comparar volumes tumorais. Resultados: A comparação dos métodos manual e semiautomático obteve valores de CSD entre 0,871 e 0,973. A comparação dos volumes segmentados pelos dois métodos de segmentação mostrou CCI entre 0,9927 e 0,9990. As análises intraobservador e interobservador obtiveram valores de CSD, respectivamente, de 0,849 a 0,979 e de 0,741 a 0,972. Não houve diferença significativa entre os tempos de segmentação dos métodos semiautomático e manual (p > 0,05). Conclusão: Houve alta similaridade entre as segmentações de sarcomas de tecidos moles obtidas pelos métodos manual e semiautomático, sem diferença significativa para o tempo despendido para as segmentações.

9.
Radiol Bras ; 54(1): 27-32, 2021.
Article in English | MEDLINE | ID: mdl-33574629

ABSTRACT

OBJECTIVE: To compare ultrasound images of the kidney obtained, randomly or in a controlled manner (standardizing the physical aspects of the ultrasound system), by various professionals and with different devices. MATERIALS AND METHODS: We evaluated a total of 919 images of kidneys, obtained by five professionals using two types of ultrasound systems, in 24 patients. The images were categorized into four types, by how they were acquired and processed. We compared the gray-scale median and different gray-scale ranges representative of virtual histological tissues. RESULTS: There were statistically significant differences among the five professionals, regardless of the type of ultrasound system employed, in terms of the gray-scale medians for the images obtained (p < 2.2e-16). Analyzing the four categories of images-a totally random image (without any standardization); a standardized image (with fixed values for gain, time gain control, and dynamic range); a normalized version of the random image; and a normalized version of the standardized image-we determined that the random image, even after normalization, differed quite significantly among the professionals (p = 0.006098). The analysis of the normalized version of the standardized image did not differ significantly among the professionals (p = 0.7319). CONCLUSION: Our findings indicate that a gray-scale analysis of ultrasound images of the kidney performs better when the image acquisition process is standardized and the images undergo a process of normalization.


OBJETIVO: Comparar imagens renais ultrassonográficas obtidas de maneira aleatória e controlada (padronizando fatores físicos do aparelho de ultrassom) por diferentes profissionais e aparelhos. MATERIAIS E MÉTODOS: Foram obtidos quatro tipos de imagens, de acordo com sua aquisição e processamento por cinco profissionais e dois tipos de aparelhos de ultrassonografia, em 24 pacientes, totalizando 919 imagens. Comparamos a mediana de escala de cinza e diferentes intervalos de tons de cinza representantes de tecidos histológicos virtuais. RESULTADOS: As medianas de escala de cinza de imagens renais obtidas por dois tipos de aparelhos foram estatisticamente diferentes (p < 2.2e-16). Analisando os quatro tipos de imagens, partindo de uma totalmente aleatória (sem qualquer padronização), uma padronizada (fixado o ganho, time gain control e dynamic range), e essas duas passando por um processo de normatização, obteve-se que a imagem aleatória é totalmente diversa entre os profissionais (p = 0,006098), mesmo passando pelo processo de normatização. A imagem padronizada, após passar pelo processo de normatização, apresentou resultados equivalentes, não possuindo diferença estatística (p = 0,7319). CONCLUSÃO: Constatou-se que na análise de tons de cinza deve-se usar um mesmo tipo de máquina e uma imagem em que sejam padronizados aspectos físicos, passando por um processo de normatização/padronização.

10.
Radiol. bras ; Radiol. bras;54(1): 27-32, Jan.-Feb. 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1155222

ABSTRACT

Abstract Objective: To compare ultrasound images of the kidney obtained, randomly or in a controlled manner (standardizing the physical aspects of the ultrasound system), by various professionals and with different devices. Materials and Methods: We evaluated a total of 919 images of kidneys, obtained by five professionals using two types of ultrasound systems, in 24 patients. The images were categorized into four types, by how they were acquired and processed. We compared the gray-scale median and different gray-scale ranges representative of virtual histological tissues. Results: There were statistically significant differences among the five professionals, regardless of the type of ultrasound system employed, in terms of the gray-scale medians for the images obtained (p < 2.2e-16). Analyzing the four categories of images-a totally random image (without any standardization); a standardized image (with fixed values for gain, time gain control, and dynamic range); a normalized version of the random image; and a normalized version of the standardized image-we determined that the random image, even after normalization, differed quite significantly among the professionals (p = 0.006098). The analysis of the normalized version of the standardized image did not differ significantly among the professionals (p = 0.7319). Conclusion: Our findings indicate that a gray-scale analysis of ultrasound images of the kidney performs better when the image acquisition process is standardized and the images undergo a process of normalization.


Resumo Objetivo: Comparar imagens renais ultrassonográficas obtidas de maneira aleatória e controlada (padronizando fatores físicos do aparelho de ultrassom) por diferentes profissionais e aparelhos. Materiais e Métodos: Foram obtidos quatro tipos de imagens, de acordo com sua aquisição e processamento por cinco profissionais e dois tipos de aparelhos de ultrassonografia, em 24 pacientes, totalizando 919 imagens. Comparamos a mediana de escala de cinza e diferentes intervalos de tons de cinza representantes de tecidos histológicos virtuais. Resultados: As medianas de escala de cinza de imagens renais obtidas por dois tipos de aparelhos foram estatisticamente diferentes (p < 2.2e-16). Analisando os quatro tipos de imagens, partindo de uma totalmente aleatória (sem qualquer padronização), uma padronizada (fixado o ganho, time gain control e dynamic range), e essas duas passando por um processo de normatização, obteve-se que a imagem aleatória é totalmente diversa entre os profissionais (p = 0,006098), mesmo passando pelo processo de normatização. A imagem padronizada, após passar pelo processo de normatização, apresentou resultados equivalentes, não possuindo diferença estatística (p = 0,7319). Conclusão: Constatou-se que na análise de tons de cinza deve-se usar um mesmo tipo de máquina e uma imagem em que sejam padronizados aspectos físicos, passando por um processo de normatização/padronização.

11.
ABCD (São Paulo, Impr.) ; 34(4): e1630, 2021. graf
Article in English, Portuguese | LILACS | ID: biblio-1360001

ABSTRACT

RESUMO - RACIONAL: O estresse oxidativo é um dos principais mecanismos associados à ruptura dos mecanismos de defesa que formam a barreira epitelial cólica e reduz o conteúdo tecidual das proteínas claudina-3 e ocludina principais constituintes das junções de oclusão intercelulares. O sucralfato, possui atividade antioxidante e tem sido usado para tratar diferentes formas de colite. OBJETIVO: Mensurar o conteúdo tecidual de claudina-3 e ocludina da mucosa do cólon sem trânsito fecal, submetido à intervenção com sucralfato. MÉTODO: Trinta e seis ratos foram submetidos à colostomia do cólon esquerdo e fístula mucosa distal. Os animais foram divididos em dois grupos de acordo com a eutanásia ser realizada duas ou quatro semanas após a intervenção. Cada grupo foi dividido em três subgrupos de acordo com o tipo de intervenção realizada diariamente: solução salina isolada; sucralfato a 1 g/kg/dia ou sucralfato a 2g/kg/dia. A colite foi diagnosticada por análise histológica adotando escala de validação prévia. A expressão tecidual de ambas as proteínas foi identificada por imunoistoquímica. O conteúdo das proteínas foi quantificado por análise de imagem assistida por computador. RESULTADOS: O escore inflamatório foi maior nos segmentos cólicos sem trânsito fecal e os enemas com sucralfato reduziram o escore inflamatório nesses segmentos, principalmente nos animais submetidos à intervenção com sucralfato em maior concentração e por período mais longo de intervenção. Houve aumento no conteúdo tecidual das proteínas claudina-3 e ocludina, relacionado com a concentração de sucralfato. O conteúdo tecidual de ambas as proteínas não se modificou com a duração da intervenção. CONCLUSÃO: Enemas com sucralfato reduzem a inflamação e aumentam o conteúdo tecidual de claudina-3 e ocludina na mucosa cólica sem trânsito intestinal.


ABSTRACT - BACKGROUND: Oxidative stress is one of the main mechanisms associated with the rupture of the defense mechanisms of the colonic epithelial barrier; it reduces the tissue content of the claudin-3 and occludin proteins, which are the main constituents of intercellular tight junctions. Sucralfate (SCF) has antioxidant activity and has been used to treat different forms of colitis. AIM: This study aimed to measure the tissue claudin-3 and occludin content of the colon mucosa without fecal transit, subjected to intervention with SCF. METHODS: Thirty-six rats were subjected to left colon colostomy and distal mucous fistula. They were divided into two groups according to euthanasia that was performed 2 or 4 weeks after the intervention. Each group was divided into three subgroups according to the enema applied daily: saline alone, SCF at 1 g/kg/day, or SCF at 2 g/kg/day. Colitis was diagnosed by the histological analysis adopting the previous validate scale. The tissue expression of both proteins was identified by immunohistochemical technique. The content of proteins was quantified by computer-assisted image analysis. RESULTS: The inflammatory score was high in colonic segments without fecal transit, and enemas with SCF reduced the inflammatory score in these segments, mainly in those animals submitted to intervention with SCF in greater concentration and for a longer period of intervention. There was an increase in tissue content of claudin-3 and occludin, related to SCF concentration. The tissue content of both proteins was not related to the intervention time. CONCLUSION: Enemas with SCF reduced the inflammation and increased the tissue content of claudin-3 and occludin in colonic mucosa without fecal stream.


Subject(s)
Animals , Rats , Sucralfate/therapeutic use , Colitis/prevention & control , Colitis/drug therapy , Rats, Wistar , Enema
12.
ABCD (São Paulo, Impr.) ; 34(2): e1608, 2021. graf
Article in English, Portuguese | LILACS | ID: biblio-1345008

ABSTRACT

ABSTRACT Background: Heart dysfunction and liver disease often coexist because of systemic disorders. Any cause of right ventricular failure may precipitate hepatic congestion and fibrosis. Digital image technologies have been introduced to pathology diagnosis, allowing an objective quantitative assessment. The quantification of fibrous tissue in liver biopsy sections is extremely important in the classification, diagnosis and grading of chronic liver disease. Aim: To create a semi-automatic computerized protocol to quantify any amount of centrilobular fibrosis and sinusoidal dilatation in liver Masson's Trichrome-stained specimen. Method: Once fibrosis had been established, liver samples were collected, histologically processed, stained with Masson's trichrome, and whole-slide images were captured with an appropriated digital pathology slide scanner. After, a random selection of the regions of interest (ROI's) was conducted. The data were subjected to software-assisted image analysis (ImageJ®). Results: The analysis of 250 ROI's allowed to empirically obtain the best application settings to identify the centrilobular fibrosis (CF) and sinusoidal lumen (SL). After the establishment of the colour threshold application settings, an in-house Macro was recorded to set the measurements (fraction area and total area) and calculate the CF and SL ratios by an automatic batch processing. Conclusion: Was possible to create a more detailed method that identifies and quantifies the area occupied by fibrous tissue and sinusoidal lumen in Masson's trichrome-stained livers specimens.


Resumo Racional: Tecnologias de imagem digital têm sido introduzidas ao diagnóstico patológico, permitindo avaliações quantitativas objetivas. A quantificação de tecido fibroso em biópsias de fígado é extremamente importante para a classificação, diagnóstico e graduação de doenças crônicas hepáticas. Objetivo: Criar um protocolo computadorizado semi-automático para quantificação de fibrose centrolobular e dilatação sinusoidal em amostras de fígado coradas por Tricrômico de Masson. Método: Uma vez instaurada a fibrose, amostras de fígado foram coletadas, processadas histologicamente, coradas por Tricrômico de Masson e WSI (Whole Slide Images) foram capturadas por scanner digital patológico apropriado. Uma seleção aleatória das regiões de interesse (ROI) foi realizada. Os dados foram submetidos a uma análise de imagem assistida por software (ImageJ®). Resultados: A análise de 250 ROIs permitiu obter-se empiricamente as melhores configurações capazes de identificar fibrose centrolobular (FC) e lúmen sinusoidal (LS). Após o estabelecimento das configurações de padrão de cor, uma Macro de autoria própria foi gravada para definir as medidas (área da fração e área total) e calcular as razões de FC e LS por processamento em grupo/lote (batch mode). Conclusão: Foi possível criar um método detalhado capaz de identificar e quantificar a área ocupada por tecido fibroso e lúmen sinusoidal em espécimes de fígado coradas por Tricrômico de Masson.


Subject(s)
Humans , Image Processing, Computer-Assisted , Software , Fibrosis , Dilatation , Liver/pathology , Liver/diagnostic imaging , Liver Cirrhosis
13.
Imaging Sci Dent ; 50(2): 161-168, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32601591

ABSTRACT

PURPOSE: The aim of this study was to evaluate the influence of voxel size and different post-processing algorithms on the analysis of dental materials using micro-computed tomography (micro-CT). MATERIALS AND METHODS: Root-end cavities were prepared in extracted maxillary premolars, filled with mineral trioxide aggregate (MTA), Biodentine, and Intermediate Restorative Material (IRM), and scanned using micro-CT. The volume and porosity of materials were evaluated and compared using voxel sizes of 5, 10, and 20 µm, as well as different software tools (post-processing algorithms). The CTAn or MeVisLab/Materialise 3-matic software package was used to perform volume and morphological analyses, and the CTAn or MeVisLab/Amira software was used to evaluate porosity. Data were analyzed using 1-way ANOVA and the Tukey test (P<0.05). RESULTS: Using MeVisLab/Materialise 3-matic, a consistent tendency was observed for volume to increase at larger voxel sizes. CTAn showed higher volumes for MTA and IRM at 20 µm. Using CTAn, porosity values decreased as voxel size increased, with statistically significant differences for all materials. MeVisLab/Amira showed a difference for MTA and IRM at 5 µm, and for Biodentine at 20 µm. Significant differences in volume and porosity were observed in all software packages for Biodentine across all voxel sizes. CONCLUSION: Some differences in volume and porosity were found according to voxel size, image-processing software, and the radiopacity of the material. Consistent protocols are needed for research evaluating dental materials.

14.
Radiol Bras ; 53(3): 148-154, 2020.
Article in English | MEDLINE | ID: mdl-32587421

ABSTRACT

OBJECTIVE: To compare automated and manual magnetic resonance imaging protocols for estimating liver iron concentrations at 1.5 T. MATERIALS AND METHODS: Magnetic resonance imaging examination of the liver was performed in 53 patients with clinically suspected hepatic iron overload and in 21 control subjects. Liver iron concentrations were then estimated by two examiners who were blinded to the groups. The examiners employed automated T2* and T1 mapping, as well as manual T2* and signal-intensity-ratio method. We analyzed accuracy by using ROC curves. Interobserver and intraobserver agreement were analyzed by calculating two-way intraclass correlation coefficients. RESULTS: The area under the ROC curve (to discriminate between patients and controls) was 0.912 for automated T2* mapping, 0.934 for the signal-intensity-ratio method, 0.908 for manual T2*, and 0.80 for T1 mapping, the last method differing significantly from the other three. The level of interobserver and intraobserver agreement was good (intraclass correlation coefficient, 0.938-0.998; p < 0.05). Correlations involving T1 mapping, although still significant, were lower. CONCLUSION: At 1.5 T, T2* mapping is a rapid tool that shows promise for the diagnosis of liver iron overload, whereas T1 mapping shows less accuracy. The performance of T1 mapping is poorer than is that of T2* methods.


OBJETIVO: Comparar protocolos automatizados e manuais de ressonância magnética para estimar a concentração hepática de ferro em 1,5 T. MATERIAIS E MÉTODOS: Foi realizada ressonância magnética hepática em 53 pacientes com suspeita de sobrecarga de ferro hepática e 21 controles, seguida da estimativa cega da concentração hepática de ferro por dois examinadores usando mapas automáticos T2* e T1, assim como o manual T2* e o método signal-intensity-ratio. O desempenho foi medido usando curvas ROC e a correlação interobservador e intraobservador usando o coeficiente de correlação intraclasse bidirecional. RESULTADOS: O desempenho da curva ROC separando pacientes e controles mostrou áreas sob a curva de 0,912 para o mapa automático T2*, 0,934 para o método signal-intensity-ratio, 0,908 para manual T2* e 0,80 para mapa T1 (este difere significativamente dos outros três métodos). Houve boa correlação interobservador e intraobservador (coeficiente de correlação intraclasse entre 0,938 e 0,998; p < 0,05). Correlações envolvendo o mapa T1, embora ainda significativas, foram menores. CONCLUSÃO: Em 1,5 T, o mapa T2* representa uma nova ferramenta rápida e promissora para avaliar o diagnóstico de sobrecarga de ferro hepática, enquanto o mapa T1 mostrou menor precisão. O desempenho do mapa T1 foi menor que o dos métodos T2*.

15.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);66(6): 818-823, June 2020. tab, graf
Article in English | Sec. Est. Saúde SP, LILACS | ID: biblio-1136279

ABSTRACT

SUMMARY INTRODUCTION Celiac disease (CeD) is an autoimmune disease that can be delayed in diagnosis due to the presence of atypical and asymptomatic cases in adulthood. Herein we aimed to study the frequency of CeD and evaluate whether magnified endoscopy and magnified/FICE (flexible spectral imaging color enhancement) techniques contribute to the diagnosis in patients with serum iron and vitamin B12 deficiency. METHODS We evaluated 50 adult patients (10 males and 40 females) who had serum iron and vitamin B12 deficiency, prospectively. All the patients had undergone upper gastrointestinal system endoscopy by the same endoscopist. The second part of the duodenum was evaluated with white light, magnified, and magnified/FICE endoscopy. Biopsy specimens were evaluated by the same pathologist. The specimens diagnosed as CeD were classified according to the Modified Marsh-Oberhuber criteria. RESULTS 10 of 50 patients (20%) were diagnosed as CeD. The average age was 41±11 years (20-67 years). Thirty percent of CeD diagnosed patients had typical CeD symptoms. Six of 10 patients (60%) who were diagnosed as CeD had typical endoscopic images under white lighted endoscopy. All of these 10 patients (100%) showed villous irregularity, partial villous atrophy, or total villous atrophy consistent with CeD with magnified and magnified/FICE endoscopy. CONCLUSION The practical use of magnified/FICE endoscopy allows us to differentiate mucosal abnormalities of the duodenum and minimize false-negative results that indicate normal mucosal findings with conventional endoscopy.


RESUMO INTRODUÇÃO A doença celíaca (DC) é uma doença autoimune que pode ter seu diagnóstico atrasado devido à presença de casos atípicos e assintomáticos na idade adulta. Neste trabalho, objetivamos estudar a frequência de DC e avaliar se as técnicas de endoscopia magnificada e magnificada/Fice (flexible spectral imaging color enhancement) contribuem para o diagnóstico em pacientes com deficiência sérica de ferro e vitamina B12. MÉTODO Foram avaliados prospectivamente 50 pacientes adultos (10 homens e 40 mulheres) com deficiência sérica de ferro e vitamina B12. Todos os pacientes foram submetidos a endoscopia digestiva alta pelo mesmo endoscopista. A segunda parte do duodeno foi avaliada com endoscopia com luz branca, magnificada e magnificada/Fice. As amostras de biópsia foram avaliadas pelo mesmo patologista. Os espécimes diagnosticados como DC foram classificados de acordo com os critérios de Marsh-Oberhuber modificado. RESULTADOS Dez dos 50 pacientes (% 20) foram diagnosticados como DC. A idade média foi de 41±11 anos (20-67 anos). Trinta por cento dos pacientes diagnosticados com DC apresentaram sintomas típicos de DC. Seis dos dez pacientes (60%) diagnosticados com DC tinham imagens endoscópicas típicas sob endoscopia de luz branca. Todos esses dez pacientes (% 100) apresentaram irregularidade das vilosidades, atrofia das vilosidades parciais ou atrofia das vilosidades totais consistentes com a DC com endoscopia magnificada e magnificada/Fice. CONCLUSÃO O uso prático da endoscopia magnificada/Fice permite diferenciar anormalidades mucosas do duodeno e minimizar os resultados falso-negativos que apresentam achados mucosais normais com a endoscopia convencional.


Subject(s)
Humans , Male , Female , Adult , Vitamin B 12 Deficiency , Celiac Disease , Image Enhancement , Endoscopy, Digestive System , Endoscopy , Iron , Middle Aged
16.
An. bras. dermatol ; An. bras. dermatol;95(3): 379-382, May-June 2020. graf
Article in English | LILACS, Coleciona SUS | ID: biblio-1130887

ABSTRACT

Abstract In situations in when a dermoscopic record of a large lesion is desirable, the resulting images are usually restricted to a small field of view due to the limited diameter of dermatoscope lenses. This limitation often produces several photographs separately, thus losing the possibility of a single-image global evaluation. In these case reports, we show examples of a recently published image montage technique called Wide Area Digital Dermoscopy, in this case, applied to basal cell carcinomas.


Subject(s)
Humans , Male , Skin Neoplasms/diagnostic imaging , Image Processing, Computer-Assisted/methods , Carcinoma, Basal Cell/diagnostic imaging , Dermoscopy/methods , Skin Neoplasms/pathology , Software , Carcinoma, Basal Cell/pathology , Reproducibility of Results , Middle Aged
17.
Radiol. bras ; Radiol. bras;53(3): 148-154, May-June 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136074

ABSTRACT

Abstract Objective: To compare automated and manual magnetic resonance imaging protocols for estimating liver iron concentrations at 1.5 T. Materials and Methods: Magnetic resonance imaging examination of the liver was performed in 53 patients with clinically suspected hepatic iron overload and in 21 control subjects. Liver iron concentrations were then estimated by two examiners who were blinded to the groups. The examiners employed automated T2* and T1 mapping, as well as manual T2* and signal-intensity-ratio method. We analyzed accuracy by using ROC curves. Interobserver and intraobserver agreement were analyzed by calculating two-way intraclass correlation coefficients. Results: The area under the ROC curve (to discriminate between patients and controls) was 0.912 for automated T2* mapping, 0.934 for the signal-intensity-ratio method, 0.908 for manual T2*, and 0.80 for T1 mapping, the last method differing significantly from the other three. The level of interobserver and intraobserver agreement was good (intraclass correlation coefficient, 0.938-0.998; p < 0.05). Correlations involving T1 mapping, although still significant, were lower. Conclusion: At 1.5 T, T2* mapping is a rapid tool that shows promise for the diagnosis of liver iron overload, whereas T1 mapping shows less accuracy. The performance of T1 mapping is poorer than is that of T2* methods.


Resumo Objetivo: Comparar protocolos automatizados e manuais de ressonância magnética para estimar a concentração hepática de ferro em 1,5 T. Materiais e Métodos: Foi realizada ressonância magnética hepática em 53 pacientes com suspeita de sobrecarga de ferro hepática e 21 controles, seguida da estimativa cega da concentração hepática de ferro por dois examinadores usando mapas automáticos T2* e T1, assim como o manual T2* e o método signal-intensity-ratio. O desempenho foi medido usando curvas ROC e a correlação interobservador e intraobservador usando o coeficiente de correlação intraclasse bidirecional. Resultados: O desempenho da curva ROC separando pacientes e controles mostrou áreas sob a curva de 0,912 para o mapa automático T2*, 0,934 para o método signal-intensity-ratio, 0,908 para manual T2* e 0,80 para mapa T1 (este difere significativamente dos outros três métodos). Houve boa correlação interobservador e intraobservador (coeficiente de correlação intraclasse entre 0,938 e 0,998; p < 0,05). Correlações envolvendo o mapa T1, embora ainda significativas, foram menores. Conclusão: Em 1,5 T, o mapa T2* representa uma nova ferramenta rápida e promissora para avaliar o diagnóstico de sobrecarga de ferro hepática, enquanto o mapa T1 mostrou menor precisão. O desempenho do mapa T1 foi menor que o dos métodos T2*.

18.
An Bras Dermatol ; 95(3): 379-382, 2020.
Article in English | MEDLINE | ID: mdl-32276794

ABSTRACT

In situations in when a dermoscopic record of a large lesion is desirable, the resulting images are usually restricted to a small field of view due to the limited diameter of dermatoscope lenses. This limitation often produces several photographs separately, thus losing the possibility of a single-image global evaluation. In these case reports, we show examples of a recently published image montage technique called Wide Area Digital Dermoscopy, in this case, applied to basal cell carcinomas.


Subject(s)
Carcinoma, Basal Cell/diagnostic imaging , Dermoscopy/methods , Image Processing, Computer-Assisted/methods , Skin Neoplasms/diagnostic imaging , Carcinoma, Basal Cell/pathology , Humans , Male , Middle Aged , Reproducibility of Results , Skin Neoplasms/pathology , Software
19.
Einstein (São Paulo, Online) ; 18: eMD5223, 2020. graf
Article in English | LILACS | ID: biblio-1056059

ABSTRACT

ABSTRACT Computed tomography with multiple detectors and the advancement of processors improved rendered images and three-dimensional reconstructions in clinical practice. Traditional axial slices form non-intuitive images because they are seen in only one plane. The three-dimensional reconstructions can show structures details and diseases with complex anatomy in different perspectives. Cinematic rendering is a newly three-dimensional reconstruction technique, already approved for clinical use, which can produce realistic images from traditional computed tomography data. The algorithm used is based on light trajectory methods and the global lighting model, which simulate thousands of images from all possible directions. Thus, the technique shapes the physical propagation of light and generates a realistic three-dimensional image with depth, shadows and more anatomic details. It is a multidimensional rendering acquired through complex lighting effects. The aim of this article was to show the advance of three-dimensional technology with the cinematic rendering in images exams of the thoracic wall.


RESUMO A tomografia computadorizada com os múltiplos detectores e o avanço dos processadores melhoraram as imagens renderizadas e as reconstruções tridimensionais na prática clínica. Os cortes axiais tradicionais formam imagens não intuitivas, pois são vistas em apenas um plano. Já as reconstruções tridimensionais podem exibir detalhes anatômicos em diferentes perspectivas das estruturas e de doenças com anatomia complexa. A renderização cinematográfica é uma técnica de reconstrução tridimensional recentemente introduzida, já aprovada para uso clínico, que pode produzir imagens realistas a partir de dados tradicionais da tomografia computadorizada. O algoritmo usado é baseado em métodos de trajetória da luz e no modelo de iluminação global, os quais simulam milhares de imagens de todas as direções possíveis. Assim, a técnica molda a propagação física da luz e gera uma imagem tridimensional realista, com profundidade, sombras e mais detalhes da alteração anatômica. É uma renderização multidimensional adquirida por efeitos de iluminação complexos. O objetivo deste artigo foi mostrar o avanço da tecnologia tridimensional com a renderização cinematográfica nos dos exames de imagens da parede torácica.


Subject(s)
Humans , Male , Adult , Thoracic Neoplasms/diagnostic imaging , Carcinoma, Squamous Cell/diagnostic imaging , Sarcoma, Synovial/diagnostic imaging , Imaging, Three-Dimensional/methods , Thoracic Wall/diagnostic imaging , Algorithms , Tomography, X-Ray Computed/methods , Sarcoma, Synovial/secondary , Middle Aged
20.
Einstein (São Paulo, Online) ; 18: eAO4948, 2020. tab, graf
Article in English | LILACS | ID: biblio-1090075

ABSTRACT

ABSTRACT Objective To develop a computational algorithm applied to magnetic resonance imaging for automatic segmentation of brain tumors. Methods A total of 130 magnetic resonance images were used in the T1c, T2 and FSPRG T1C sequences and in the axial, sagittal and coronal planes of patients with brain cancer. The algorithms employed contrast correction, histogram normalization and binarization techniques to disconnect adjacent structures from the brain and enhance the region of interest. Automatic segmentation was performed through detection by coordinates and arithmetic mean of the area. Morphological operators were used to eliminate undesirable elements and reconstruct the shape and texture of the tumor. The results were compared with manual segmentations by two radiologists to determine the efficacy of the algorithms implemented. Results The correlated correspondence between the segmentation obtained and the gold standard was 89.23%. Conclusion It is possible to locate and define the tumor region automatically with no the need for user interaction, based on two innovative methods to detect brain extreme sites and exclude non-tumor tissues on magnetic resonance images.


RESUMO Objetivo Desenvolver um algoritmo computacional aplicado a imagens de ressonância magnética, para segmentação automática de tumores cerebrais. Métodos Foram utilizadas 130 imagens de ressonância magnética nas sequências T1c, T2 e FSPRG T1c e nos planos axial, sagital e coronal de pacientes acometidos com câncer cerebral. Os algoritmos empregaram técnicas de correção de contraste, normalização de histograma e binarização, para desconectar estruturas adjacentes do cérebro e realçar a região de interesse. A segmentação automática foi realizada por meio da detecção por coordenadas e por média aritmética da área. Operadores morfológicos foram utilizados para eliminar elementos indesejáveis e reconstruir a forma e a textura do tumor. Os resultados foram comparados com as segmentações manuais de dois médicos radiologistas, para determinar a eficácia dos algoritmos implementados. Resultados Os acertos foram de 89,23% na correspondência entre a segmentação obtida e o padrão-ouro. Conclusão É possível localizar e delimitar a região tumoral de forma automática, sem necessidade de interação com o usuário baseado em dois métodos inovadores de detecção dos extremos do cérebro e de exclusão dos tecidos não tumorais em imagens de ressonância magnética.


Subject(s)
Humans , Algorithms , Image Processing, Computer-Assisted/methods , Brain Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Reference Standards , Brain , Reproducibility of Results , Diagnosis, Computer-Assisted/methods