Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Imaging Sci Dent ; 52(1): 27-32, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35387098

ABSTRACT

Purpose: The aim of this study was to compare mastoid air cell volumes in patients with or without a pneumatized articular tubercle (PAT) on cone-beam computed tomography (CBCT) images. Materials and Methods: The CBCT images of 224 patients were retrospectively analyzed for the presence of PAT. The Digital Imaging and Communications in Medicine data of 30 patients with PAT and 30 individuals without PAT were transferred to 3D Doctor Software. Mastoid air cell volumes were measured using semi-automatic segmentation on axial sections. Data were analyzed using SPSS version 20.0. Results: The patients with PAT and those without PAT had a mean mastoid volume of 6.31±2.86 cm3 and 3.25±1.99 cm3, respectively. There were statistically significant differences in mastoid air cell volumes between patients with and without PAT regardless of sex and mastoid air cell side (P<0.05). Conclusion: The detection of PAT on routine dental radiographic examinations might be a potential prognostic factor that could be used to detect extensive pneumatization in the temporal bone. Clinicians should be aware that there may be widespread pneumatization of mastoid air cells in patients in whom PAT is detected. Advanced imaging should be performed in these cases, and possible complications due to surgical interventions should be considered.

2.
Arq. bras. cardiol ; 117(1): 84-88, July. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1285217

ABSTRACT

Resumo Fundamento A fístula da artéria coronária (FAC) é uma conexão direta entre uma ou mais artérias coronárias e câmaras cardíacas ou um grande vaso; pode estar associada à cardiopatia congênita. Objetivo Estabelecer os padrões de trajetos de FAC a partir de dados ecocardiográficos e correlacioná-los com aspectos clínicos e cardiopatias congênitas. Métodos Um total de 7.183 prontuários médicos de crianças menores de 5 anos de idade com cardiopatia submetidas a ecodopplercardiograma colorido foram analisados utilizando o teste de correlação de Spearman para associar sinais, sintomas e cardiopatia à FAC, com nível de significância de 5%. Resultados Vinte e seis crianças (0,0036%) apresentaram FAC, nos seguintes trajetos: da artéria coronária direita para o ventrículo direito (26,92%), da artéria coronária esquerda para o ventrículo direito (23,08%), do ramo interventricular anterior para o ventrículo direito (23,08%), da artéria coronária direita para o átrio direito (11,54%), da artéria coronária esquerda para o tronco pulmonar (7,69%) e do ramo interventricular anterior para o tronco pulmonar (7,69%). Em 57,69% dos pacientes, houve uma correlação positiva entre sintomas e a FAC (p = 0,445), relacionada à dispneia ou cianose (53,84%). Em 96,15%, a cardiopatia congênita estava associada à FAC; principalmente, a comunicação interventricular e a comunicação interatrial, em 34,62% dos casos, correlacionaram-se positivamente com a FAC (p = 0,295). O trajeto da FAC foi representado em três dimensões pelo software de modelagem, texturização e animação Cinema 4D R19. Conclusão A FAC é uma entidade anatômica incomum que apresenta quadro clínico compatível com dispneia e cianose e está associada a cardiopatias congênitas, principalmente com a CIV ou a CIA. De acordo com as análises ecocardiográficas, as fístulas na ACD, na ACE ou no RIVA representam aproximadamente um terço dos pacientes, com trajeto prioritário para as câmaras cardíacas direitas.


Abstract Background Coronary artery fistula (CAF) is a direct connection of one or more coronary arteries to cardiac chambers or a large vessel; it may be associated with congenital heart disease. Objective To establish CAF pathway patterns from echocardiographic data and to correlate them with clinical aspects and congenital heart disease. Methods A total of 7.183 medical records of children under the age of five years with cardiac disease submitted to color Doppler echocardiography and Spearman's Correlation test were used to associate signs and symptoms and cardiopathy to CAF with a significance level of 5%. Results Twenty six children (0.0036%) presented CAF: from the right coronary artery (RCA) to the right ventricle (RV) 26.92%, from the left coronary artery (LCA) to the RV 23.08%, from the anterior interventricular branch (AIVB) to RV 23.08%, RCA to right atrium (RA) 11.54%, LCA for pulmonary trunk (PT) 7.69% or AIVB for PT 7.69%. In 57.69% of the patients, there was a positively correlated symptomatology to CAF with p=0.445 related to dyspnea or cyanosis (53.84%); in 96.15%, congenital heart disease associated with CAF, mainly interventricular communication (IVC) or interatrial communication (IAC) in 34.62% positively correlated to CAF with p=0.295. CAF pathway was represented in three dimensions by software modeling, texturing and animation Cinema 4D R19. Conclusion CAF is an uncommon anatomical entity that presents a clinical picture compatible with dyspnea and cyanosis, and this is associated with congenital heart disease, mainly with IVC or IAC. According to echocardiographic analyzes, fistulas in RCA, LCA, or AIVB represent about one-third of the patients, with a priority pathway for right heart chambers.


Subject(s)
Humans , Child, Preschool , Child , Coronary Artery Disease , Coronary Vessel Anomalies/diagnostic imaging , Fistula , Heart Atria
3.
Radiol Bras ; 54(3): 177-184, 2021.
Article in English | MEDLINE | ID: mdl-34108765

ABSTRACT

Cone-beam computed tomography (CBCT) has been applied in dentistry and medicine for nearly two decades. Its application in the foot and ankle specialty has grown exponentially in recent years. Weight-bearing CBCT allows clinicians to obtain weight-bearing images that can be viewed in all three planes and to construct three-dimensional models, similar to those constructed from traditional CT scans, as well as exposing patients to less radiation than do traditional CT scans. This technology has revolutionized diagnoses, improving the understanding of various lesions and surgical planning in the foot and ankle specialty. Ongoing studies of the use of weight-bearing CBCT in foot and ankle surgery are focused on fully automated and semi-automated three-dimensional measurements, as well as bone segmentation, mapping of the distances/orientation of the joints, and the production of customized implants. The aims of this review article are to show the evolution of this emerging tool in the foot and ankle specialty, to update those in related specialties on its use in current clinical practice, and to indicate where the research community is heading.


A tomografia computadorizada (TC) de feixe cônico é aplicada na área da odontologia e medicina há cerca de duas décadas, e seu uso na especialidade do tornozelo e pé cresceu de forma exponencial nos últimos anos. A literatura demonstra como a TC de feixe cônico permite obter imagens com apoio do peso corporal total - weight-bearing cone-beam computed tomography - com cortes nos três planos e modelos tridimensionais semelhantes às TCs, associada a menor exposição à radiação, técnica que revolucionou o diagnóstico, o entendimento de diferentes lesões e o planejamento cirúrgico nessa área do conhecimento. As mensurações tridimensionais automáticas e semiautomáticas, a segmentação óssea, o mapeamento das distâncias e orientações articulares e a possibilidade de produção de implantes customizados são o interesse dos estudos em andamento na cirurgia do tornozelo e pé relacionados a essa ferramenta emergente. O objetivo deste artigo é mostrar a evolução do método, atualizar as especialidades de interface sobre uso na prática clínica atual e indicar para onde a comunidade científica está caminhando.

4.
Radiol. bras ; 54(3): 177-184, May-June 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1250657

ABSTRACT

Abstract Cone-beam computed tomography (CBCT) has been applied in dentistry and medicine for nearly two decades. Its application in the foot and ankle specialty has grown exponentially in recent years. Weight-bearing CBCT allows clinicians to obtain weight-bearing images that can be viewed in all three planes and to construct three-dimensional models, similar to those constructed from traditional CT scans, as well as exposing patients to less radiation than do traditional CT scans. This technology has revolutionized diagnoses, improving the understanding of various lesions and surgical planning in the foot and ankle specialty. Ongoing studies of the use of weight-bearing CBCT in foot and ankle surgery are focused on fully automated and semi-automated three-dimensional measurements, as well as bone segmentation, mapping of the distances/orientation of the joints, and the production of customized implants. The aims of this review article are to show the evolution of this emerging tool in the foot and ankle specialty, to update those in related specialties on its use in current clinical practice, and to indicate where the research community is heading.


Resumo A tomografia computadorizada (TC) de feixe cônico é aplicada na área da odontologia e medicina há cerca de duas décadas, e seu uso na especialidade do tornozelo e pé cresceu de forma exponencial nos últimos anos. A literatura demonstra como a TC de feixe cônico permite obter imagens com apoio do peso corporal total - weight-bearing cone-beam computed tomography - com cortes nos três planos e modelos tridimensionais semelhantes às TCs, associada a menor exposição à radiação, técnica que revolucionou o diagnóstico, o entendimento de diferentes lesões e o planejamento cirúrgico nessa área do conhecimento. As mensurações tridimensionais automáticas e semiautomáticas, a segmentação óssea, o mapeamento das distâncias e orientações articulares e a possibilidade de produção de implantes customizados são o interesse dos estudos em andamento na cirurgia do tornozelo e pé relacionados a essa ferramenta emergente. O objetivo deste artigo é mostrar a evolução do método, atualizar as especialidades de interface sobre uso na prática clínica atual e indicar para onde a comunidade científica está caminhando.

5.
Ergonomics ; 63(7): 850-863, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32301393

ABSTRACT

This study aimed to provide normative data characterising the breast size, breast position and torso size of female contact football players. 117 AFL, Rugby League, Rugby Union and Rugby 7s players attended a single testing session where a three-dimensional scan was taken of their naked breasts and torso. Dimensions relevant to the design of sports bras and breast protective equipment were then calculated from the scans. Several breast and torso characteristics of female contact football athletes differed to measurements reported for females in the general population and amongst the contact football codes. Designers and manufacturers of sports bras or breast protective equipment should consider the specific breast and torso dimensions of female contact football players to maximise the fit, comfort and efficacy of these garments. Practitioner summary: Using three-dimensional scanning, this study characterised the breast and torso size and shape of 117 female contact football players. These normative data should be used to improve the fit and comfort of sports bras and breast protective equipment for female contact football players.


Subject(s)
Breast/anatomy & histology , Equipment Design , Football , Protective Clothing , Sports Equipment , Torso/anatomy & histology , Adult , Athletic Injuries/prevention & control , Female , Humans , Young Adult
6.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 65(7): 959-964, July 2019. graf
Article in English | LILACS | ID: biblio-1013021

ABSTRACT

SUMMARY OBJECTIVE The purpose of this study is to evaluate the efficacy of the combination of gynecologic imaging reporting and data system (GI-RADS) ultrasonographic stratification and three-dimensional contrast-enhanced ultrasonography (3D-CEUS) in order to distinguish malignant from benign ovarian masses. METHODS In this study, 102 patients with ovarian masses were examined by both two-dimensional ultrasound(2D-US) and 3D-CEUS. Sonographic features of ovarian masses obtained from 3D-CEUS were analyzed and compared with 2D-US. All patients with ovarian masses were confirmed by operational pathology or long-term follow-up results. RESULTS (1)The Chi-square test and multiple Logistic regression analysis confirmed that there were only eight independent predictors of malignant masses, including thick septa (≥3mm), thick papillary projections(≥7mm), solid areas, presence of ascites, central vascularization, contrast enhancement, distribution of contrast agent, and vascular characteristics of the solid part and their odds ratios which were 5.52, 5.39, 4.94, 4.34, 5.92, 7.44, 6.09, and 7.67, respectively (P<0.05). (2)These eight signs were used to combine the GI-RADS with 3D-CEUS scoring system in which the corresponding value of the area under the curve (AUC) was 0.969, which was superior to using GI-RADS lonely (Z-value=1.64, P<0.025). Using 4 points as the cut-off, the scoring system showed the performance was clearly better than using GI-RADS alone (P<0.05). (3) The Kappa value was 0.872 for two different clinicians with equal experience. CONCLUSIONS The combination of GI-RADS and 3D-CEUS scoring system would be a more effective method to distinguish malignant from benign ovarian masses.


RESUMO OBJETIVO O objetivo deste estudo é avaliar a eficácia da combinação da estratificação por ultrassonografia usando o Sistema de Relatórios e Dados de Imagem Ginecológica (GI-RADS) e ultrassonografia 3D com contraste (3D-CEUS) para diferenciar massas ovarianas benignas de malignas. METODOLOGIA Neste estudo, 102 pacientes com massas ovarianas foram examinadas usando ultrassonografia bidimensional (2D-US) e 3D-CEUS. As características ultrassonográficas das massas ovarianas obtidas com 3D-CEUS foram analisadas e comparadas com de 2D-US. Todos os pacientes com massas ovarianas tiveram o diagnóstico confirmado pelos resultados de patologia cirúrgica ou acompanhamento de longo prazo. RESULTADOS (1) O teste qui-quadrado e a regressão logística múltipla confirmaram a existência de apenas oito preditores independentes de massas malignas, incluindo septos espessos (≥3mm), projeções papilares espessas (≥7mm), áreas sólidas, presença de ascite, vascularização central, aumento de contraste, distribuição do agente de contraste e características vasculares da parte sólida e suas razões de possibilidades (OR), que foram 5,52, 5,39, 4,94, 4,34, 5,92, 7,44, 6,09 e 7.67, respectivamente (P< 0,05). (2) Esses oito preditores foram utilizados para combinar o GI-RADS com o sistema de escores da 3D-CEUS, para o qual o valor correspondente da área sob a curva (AUC) foi de 0,969, superior ao uso exclusivo do GI-RADS (valor de Z = 1,64, P < 0,025). Usando 4 pontos como corte, o sistema de escores mostrou que o desempenho foi muito melhor do que com o uso exclusivo do GI-RADS (P < 0,05). (3) O valor de Kappa foi 0,872, obtido por dois médicos diferentes com igual experiência. CONCLUSÃO A combinação do GI-RADS e do sistema de pontuação da 3D-CEUS é um método mais eficaz para distinguir massas ovarianas benignas de malignas.


Subject(s)
Humans , Female , Adolescent , Adult , Young Adult , Ovarian Diseases/diagnostic imaging , Ovarian Neoplasms/diagnostic imaging , Ovarian Diseases/pathology , Ovarian Neoplasms/pathology , Reference Values , Adenocarcinoma/pathology , Adenocarcinoma/diagnostic imaging , Logistic Models , Predictive Value of Tests , Reproducibility of Results , Ultrasonography/methods , Sensitivity and Specificity , Diagnosis, Differential , Middle Aged
7.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-637669

ABSTRACT

Background The optic quality of Toric intraocular lens (IOL)-implanted eye is affected by the residual astigmatism and individual difference of corneal spherical aberration and different magnification from steep and flat axis refraction.Whether correcting Toric IOL spherical aberration can effectively improve the image quality of individual patient is a question to be studied.Objective This study attempted to collect eye parameters of cataract patients to reconstruct the customized vision model by using Zemax optical software,and to evaluate the image performance with different Toric IOL spherical aberration.Methods A prospective study was performed.Forty-five eyes of 45 cataract patients were included in Second Hospital of Hebei Medical University from August 2012 to October 2013.Several relevant parameters were measured by Pentacam,including anterior and posterior surface height of cornea,corneal thickness,curvature radius of flat and steep meridians of anterior surface astigmatism,refractive diopter and curvature radius of posterior surface.The astigmatism of anterior and posterior corneal surface was described by Matlab 4.5 software.Corneal astigmatism model were set as aspheric state,and the effective position of Toric IOL was calculated using Holladay Ⅰ formula.Customized individual model eyes were constructed by Zemax software.The contrast sensitivity function (CSF) of different spherical Toric IOLs at different spatial frequencies were calculated and compared between 300 Td light environment with 3 mm pupil diameter (photopia light) and 0.3-1.0 Td light environment with 5 mm pupil diameter (mesopia light).This study was approved by Second Hospital of Hebei Medical University ethics committee,all the patients signed the informed consent.Results The mean astigmatism power was (1.51 ± 0.36) D and (1.49 ± 0.37) D,and the mean astigmatism meridian was (101.5 ± 59.8) ° and (101.9±58.5) ° in the model eyes and cataract eyes,respectively,without significant differences between them (t=0.886,0.652;both at P>0.05).Bland-Altman test showed a good agreement in astigmatism power and astigmatism meridian between model eyes and cataract eyes.The LogCSF values at 1.5,3.0,6.0,12.0 and 18.0 c/d spatial frequencies were significantly higher in the aspherical Toric IOL model eyes than those in the spherical Toric IOL model eyes,and the LogCSF values at various spatial frequencies were significantly higher in the Toric IOLs with spherical aberrations of-0.13 μm and-0.26 μm than those in the zero spherical aberrations in both photopia light and mesopia light (all at P<0.05).Conclusions A precise corneal astigmatism model based on cornea high data of cataract eyes was successfully constructed through special formulas with Zemax software.Aspherical Toric IOL can compensate for spherical aberration of cornea and enhance the optic quality in individual model eye.

8.
Tex Heart Inst J ; 42(4): 372-6, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26413022

ABSTRACT

Transesophageal echocardiography continues to have a central role in the diagnosis of infective endocarditis and its sequelae. Recent technological advances offer the option of 3-dimensional imaging in the evaluation of patients with infective endocarditis. We present an illustrative case and review the literature regarding the potential advantages and limitations of 3-dimensional transesophageal echocardiography in the diagnosis of complicated infective endocarditis. A 51-year-old man, an intravenous drug user who had undergone bioprosthetic aortic valve replacement 5 months earlier, presented with prosthetic valve endocarditis. Preoperative transesophageal echocardiography with 3D rendition revealed a large abscess involving the mitral aortic intervalvular fibrosa, together with a mycotic aneurysm that had ruptured into the left atrium, resulting in a left ventricle-to-left atrium fistula. Three-dimensional transesophageal echocardiography enabled superior preoperative anatomic delineation and surgical planning. We conclude that 3-dimensional transesophageal echocardiography can be a useful adjunct to traditional 2-dimensional transesophageal echocardiography as a tool in the diagnosis of infective endocarditis.


Subject(s)
Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Endocarditis, Bacterial/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis/adverse effects , Mitral Valve/diagnostic imaging , Substance Abuse, Intravenous/complications , Aneurysm, False/diagnostic imaging , Aneurysm, False/microbiology , Aneurysm, False/surgery , Aneurysm, Infected/diagnostic imaging , Aneurysm, Infected/microbiology , Aneurysm, Infected/surgery , Anti-Bacterial Agents/therapeutic use , Aortic Valve/microbiology , Aortic Valve/surgery , Bicuspid Aortic Valve Disease , Endocarditis, Bacterial/microbiology , Endocarditis, Bacterial/surgery , Heart Valve Diseases/complications , Heart Valve Diseases/diagnostic imaging , Heart Valve Prosthesis Implantation/instrumentation , Humans , Male , Middle Aged , Mitral Valve/microbiology , Mitral Valve/surgery , Predictive Value of Tests , Preoperative Care , Reoperation , Treatment Outcome
9.
Tex Heart Inst J ; 40(3): 250-5, 2013.
Article in English | MEDLINE | ID: mdl-23914013

ABSTRACT

We used 3-dimensional computed tomographic images to create a disease-based transesophageal echocardiographic simulation system for complex congenital heart defects. We enrolled 7 pediatric patients with complex congenital heart defects in this proof-of-concept study. Preoperative computed tomographic images and intraoperative transesophageal echocardiographic images were acquired for all patients. Two- and 3-dimensional computed tomographic cross-sectional images were created to simulate the process of transesophageal echocardiographic image acquisition. Computed tomographic images simulating the midesophageal 4- and 5-chamber views, aortic valve short-axis views, long-axis views, and ascending aortic short-axis views were created to correspond with the actual transesophageal echocardiographic images from each patient. Four reviewers then evaluated the image quality of the computed tomographic images, the agreement between the echocardiographic and tomographic images, and the ability of the 3-dimensional computed tomographic full-volume and cross-sectional images to yield the spatial and temporal congruence of transesophageal echocardiograms. In most of the patients, computed tomography yielded images of good-to-excellent quality. Strong agreement was noted between the computed tomographic and transesophageal echocardiographic images acquired in the same patients. The ability of 3-dimensional computed tomography to yield the spatial and temporal congruence of transesophageal echocardiography in selected planes was also good to excellent. We found that 3-dimensional computed tomographic images can simulate the process of transesophageal echocardiography in acquiring the echocardiographic image clearly. This imaging method has the potential to be applied successfully to a disease-based transesophageal echocardiographic simulation system.


Subject(s)
Computer Simulation , Echocardiography, Transesophageal , Heart Defects, Congenital/diagnostic imaging , Imaging, Three-Dimensional , Multimodal Imaging/methods , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed , Adolescent , Cardiac Surgical Procedures , Child , Child, Preschool , Echocardiography, Doppler, Color , Female , Heart Defects, Congenital/surgery , Humans , Infant , Male , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Surgery, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...