Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 937
Filter
1.
Article in English | MEDLINE | ID: mdl-38989676

ABSTRACT

BACKGROUND: There is limited knowledge on the fabrication trueness and fit of additively or subtractively manufactured complete-arch implant-supported frameworks in recently introduced polymers. PURPOSE: To evaluate the trueness and marginal fit of additively or subtractively manufactured polymer-based complete-arch implant-supported frameworks, comparing with those of strength gradient zirconia frameworks. MATERIALS AND METHODS: A typodont model with 4 implants (left first molar (abutment 1), left canine (abutment 2), right canine (abutment 3), and right first molar (abutment 4)) was digitized (ATOS Core 80 5MP) and an implant-supported complete-arch framework was designed. This design file was used to fabricate frameworks from 5 different materials: strength gradient zirconia (SM-ZR), high impact polymer composite (SM-CR), nanographene-reinforced PMMA (SM-GR), PMMA (SM-PM), and additively manufactured temporary resin (AM) (n = 10). These frameworks were digitized and each scan file was virtually segmented into 4 regions (abutments, occlusal, overall without occlusal, and overall). The surface deviations at these regions, and linear and interimplant distance deviations were evaluated (Geomagic Control X). Marginal gaps were evaluated according to triple-scan protocol after seating frameworks on the model with the 1-screw test. Data were statistically analyzed (α = 0.05). RESULTS: Surface deviations of all regions differed among tested materials (p ≤ 0.001). AM frameworks mostly had surface deviations that were similar to or lower than those of other materials (p ≤ 0.031), except for the occlusal surface, where it mostly had higher deviations (p ≤ 0.013). Abutment 4 of SM-CR had higher linear deviations than abutment 2 (p = 0.025), and material type did not affect the linear deviations within abutments (p ≥ 0.171). Interimplant distance deviations differed within and among materials (p ≤ 0.017), except for those between abutments 1 and 2 among materials (p = 0.387). Marginal gaps of subtractively manufactured materials differed among abutments, while those of abutments 3 and 4 differed among materials (p ≤ 0.003). AM frameworks mostly had lower marginal gaps at abutments 3 and 4 (p ≤ 0.048). CONCLUSIONS: Although there was no clear trend among tested materials for measured deviations, marginal gaps of additively manufactured resin were mostly lower than those of subtractively manufactured materials and did not differ among abutment sites. Nevertheless, the differences in measured deviations among materials were small and marginal gaps were within the previously reported acceptability thresholds.

2.
Article in English | MEDLINE | ID: mdl-38953771

ABSTRACT

OBJECTIVES: One stage functional jaw reconstruction is defined as the resection and reconstruction of segmental defects in conjunction with the placement of dental implants in an ideal prosthetic position and loaded with a provisional restoration, during one surgical procedure. The aim of the study is to describe clinical outcomes of patients who underwent one stage functional jaw reconstruction. METHODS: Patients who underwent one-stage functional jaw reconstruction, from January 2013 to March 2016 were recalled in 2022 and 2023. Planning and execution for the reconstruction utilized either analogue or digital techniques. Outcome parameters recorded were treatment-related outcomes at patient level, implant-related outcomes and patient-reported outcome measures. RESULTS: Eighteen patients underwent one-stage jaw reconstruction with a total of 57 implants. Four patients had maxillary and 14 had mandibular reconstructions. Ten patients underwent postoperative radiotherapy. Ten patients were planned using analogue and eight by digital planning. Three patients had partial flap necrosis, three patients had plate fractures, implant loss was seen in one patient and four patients died during the period. A functional prosthesis was provided in 16 out of the 18 patients. CONCLUSION: One-stage functional jaw reconstruction is a predictable method for providing rehabilitation with successful outcomes at 7-11 years. However, caution should be exercised when the treatment modality is carried out in patients with malignant pathologies who have undergone radiotherapy.

3.
Cureus ; 16(6): e61658, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38966469

ABSTRACT

There is a lack of consensus on managing resultant bone and soft tissue defects or on restoring oral function and aesthetics following medication-related osteonecrosis of the jaws (MRONJ) lesion healing. This clinical challenge presents a dilemma for practitioners. Removable prostheses pose a recurrence risk if poorly fitted and may inadequately restore function or aesthetics in cases of significant bone defect. Dental implant-supported prostheses could enhance function and quality of life, though their risks and indications are not well-defined. This systematic review examines the clinical outcomes and complications associated with implant-supported rehabilitations post-MRONJ surgery. This study was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement recommendations and it was pre-registered in the Prospective Register of Systematic Reviews (PROSPERO) (CRD42023492539).

4.
J Oral Implantol ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38962860

ABSTRACT

This study aimed to identify the ideal inter-implant distance for optimum outcome on immediately loaded implant supported prosthesis. Hence this study was taken up to analyze the effect of varying inter-implant distance on fracture resistance of implant supported provisional FDP. A total of 24 bis-acrylate composite resin samples were prepared. Inter- implant distance was present in the metal die for placement of dummy implants at distances of 14 mm, 21 mm & 30 mm respectively. Wax-up for 3 unit, 4 unit & 5 unit implant supported provisional restoration were made. Silicone molds were used for making multiple interim prostheses using bis-acrylate composite material. All samples were subjected to fracture test in the universal testing machine with a crosshead speed of 1 mm/min. All samples were loaded with gradual force starting from 100 N till it fractured. The Load was applied at the center of prosthesis. Data was analyzed by one way ANOVA and Bonferroni post hoc test. Mean Fracture resistance of 3 unit provisional FDP at 14 mm of inter-implant distance showed 1342.61 ± 179.15 N. Mean Fracture resistance of 4 unit provisional FDP at 21 mm of inter-implant distance showed 1420.44 ± 170.37 N. Mean Fracture resistance of 5 unit provisional FDP at 30 mm of inter-implant distance showed 791.61 ± 203.59 N. Both 14mm and 21mm of inter implant distance are suitable span lengths to be considered for the optimum outcome during immediately loading with implant supported provisional restorations. Limitations of the study was force application was static in nature and not dynamic and the arch form was not "U" shaped but longitudinal using Bis-Acrly material only with no cantilever. Future studies can be done to evaluate the fracture resistance of bis- acrylate material considering biomechanics and arch form of natural dentition. Distal cantilever should be considered along with different material for fabricating provisional restoration.

5.
Article in English | MEDLINE | ID: mdl-38864592

ABSTRACT

Restorative material selection has become increasingly challenging due to the speed of new developments in the field of dental material science. The present narrative review gives an overview of the current indications for implant abutments and restoration materials for provisional and definitive implant-supported fixed dental prostheses in partially edentulous patients. For single implant restorations, titanium base abutments for crowns are suggested as an alternative to the conventional stock- and customized abutments made out of metal or zirconia. They combine the mechanical stability of a metallic connection with the esthetic potential of ceramics. For multiple-unit restorations, conical titanium bases especially designed for bridges are recommended, to compensate for deviating implant insertion axes and angulations. Even though titanium base abutments with different geometries and heights are available, certain clinical scenarios still benefit from customized titanium abutments. Indications for the definitive material in fixed implant restorations depend on the region of tooth replacement. In the posterior (not esthetically critical) zone, ceramics such as zirconia (3-5-Ymol%) and lithium-disilicate are recommended to be used in a monolithic fashion. In the anterior sector, ceramic restorations may be buccally micro-veneered for an optimal esthetic appearance. Lithium-disilicate is only recommended for single-crowns, while zirconia (3-5-Ymol%) is also recommended for multiple-unit and cantilever restorations. Attention must be given to the specific mechanical properties of different types of zirconia, as some feature reduced mechanical strengths and are therefore not indicated for all regions and restoration span lengths. Metal-ceramics remain an option, especially for cantilever restorations.

6.
Cureus ; 16(5): e60267, 2024 May.
Article in English | MEDLINE | ID: mdl-38872639

ABSTRACT

The absence of any organ of the facial region causes an asymmetrical appearance. This asymmetrical appearance can cause social dilemmas for the patient. The maxillofacial technician, the prosthodontist, and the patient must work closely together to fabricate an epithesis. On the implants, a superstructure is first constructed. Most of it is made up of rings and a bar that joins the implants. The firm acrylic resin base of the epithesis is equipped with clips that serve as the epithesis's retention mechanism. The actual epithesis is made of silicone rubber. The epithesis has to be shaped and colored with extreme caution. An appropriate substitute is an auricular prosthesis that is implant-retained. Microtia, deformity, malformation, and loss of the external ear, either partially or completely, can result from a variety of inherited genetic conditions. To evaluate the symmetry of both ears, artificial intelligence (AI) software is used. An Instagram lens Gridset by crystalwavesxx was used to correct and verify the bilateral symmetry of the patient. This case report primarily focuses on the fabrication of implant-supported auricular prostheses using AI.

7.
Article in English | MEDLINE | ID: mdl-38867397

ABSTRACT

OBJECTIVE: This study explored factors affecting speech improvement in patients with an edentulous maxilla after the delivery of a complete-arch implant-supported fixed dental prosthesis (IFDP). MATERIALS AND METHODS: Patients who had received IFDP for edentulous maxilla were enrolled, and various potential speech improvement-related factors were considered, including patient demographics, anterior residual bone volume, preoperative facial features, preoperative acoustic parameters, and adaptation time. Acoustic analysis and perceptual ratings were used to assess three fricatives [s], [f], and [ɕ]. Correlation and regression analyses were conducted to assess the association between changes in fricatives and potential factors (α = .05). RESULTS: The study included 50 patients (18 females and 32 males, aged 50.62 ± 15.71 years, range 19-76). Significant correlations were found among the change in the center of gravity (ΔCoG) of [s] and anterior residual bone volume, zygomatic implants number and proportion (p < .05). These correlations were largely mirrored in the perceptual score (ΔPS) changes. After controlling for age, sex, preoperative acoustic parameters, and adaptation time, the ΔCoG and ΔPS of fricatives were mainly correlated with the anterior residual bone volume, preoperative acoustic parameters, and adaptation time. CONCLUSION: Speech improvements post-IFDP delivery are mainly related to preoperative speech characteristics, anterior residual bone volume, and adaptation time. The residual bone volume's impact on consonants varies with specific articulatory gestures. This study provides insights into forecasting speech outcomes following IFDP restoration and provides recommendations and methods for data collection in developing future prediction models.

8.
J Dent ; 147: 105142, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38906454

ABSTRACT

OBJECTIVES: To compare implant supported crowns (ISCs) designed using deep learning (DL) software with those designed by a technician using conventional computer-aided design software. METHODS: Twenty resin-based partially edentulous casts (maxillary and mandibular) used for fabricating ISCs were evaluated retrospectively. ISCs were designed using a DL-based method with no modification of the as-generated outcome (DB), a DL-based method with further optimization by a dental technician (DM), and a conventional computer-aided design method by a technician (NC). Time efficiency, crown contour, occlusal table area, cusp angle, cusp height, emergence profile angle, occlusal contacts, and proximal contacts were compared among groups. Depending on the distribution of measured data, various statistical methods were used for comparative analyses with a significance level of 0.05. RESULTS: ISCs in the DB group showed a significantly higher efficiency than those in the DM and NC groups (P ≤ 0.001). ISCs in the DM group exhibited significantly smaller volume deviations than those in the DB group when superimposed on ISCs in the NC group (DB-NC vs. DM-NC pairs, P ≤ 0.008). Except for the number and intensity of occlusal contacts (P ≤ 0.004), ISCs in the DB and DM groups had occlusal table areas, cusp angles, cusp heights, proximal contact intensities, and emergence profile angles similar to those in the NC group (P ≥ 0.157). CONCLUSIONS: A DL-based method can be beneficial for designing posterior ISCs in terms of time efficiency, occlusal table area, cusp angle, cusp height, proximal contact, and emergence profile, similar to the conventional human-based method. CLINICAL SIGNIFICANCE: A deep learning-based design method can achieve clinically acceptable functional properties of posterior ISCs. However, further optimization by a technician could improve specific outcomes, such as the crown contour or emergence profile angle.

9.
Cureus ; 16(5): e60886, 2024 May.
Article in English | MEDLINE | ID: mdl-38910621

ABSTRACT

Effective treatment planning is crucial for implant-supported dental prostheses' success, requiring a thorough assessment of various factors, including bone quality, quantity, and available space. Evaluating space availability, encompassing height, width, and angulation, is imperative to ensure optimal implant positioning devoid of anatomical limitations. Adequate vertical space is essential for accommodating the implant-supported restoration while preserving proper occlusal function and esthetics. However, not all cases adhere to ideal standards, especially those featuring limited interocclusal space, as seen in scenarios of long-standing edentulous areas lacking prior prosthetic rehabilitation. Ideally, the interocclusal space should measure between 8-12 mm vertically. This case report details the management of reduced interocclusal space through the strategic placement of deeply positioned implants and the incorporation of a screw-retained fixed partial denture, effectively addressing the challenges associated with limited space.

10.
Int J Oral Maxillofac Implants ; 0(0): 1-24, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38941168

ABSTRACT

PURPOSE: To retrospectively evaluate the long-term clinical, technical, biological, and esthetic outcomes of implant supported single zirconia crowns (ISCs) intraorally cemented to Ti-base hybrid-abutments up to 16 years after placement. MATERIALS AND METHODS: A total of 63 ISCs (Xive S, Camlog Screw Line, Replace Select TC NP, Branemark MK II, and 3i Osseotite) were evaluated in 36 patients at two different centers. Original Ti-bases were selected and zirconia meso structures and zirconia crowns were designed using CAD/CAM software and then milled from partially stabilized zirconia blocks. After the meso structures were cemented extraorally onto the Ti-bases, the ceramic crowns were intraorally luted to the hybrid abutments. The Ti-base ISC restorations were followed up for up to 16 years, and their clinical, biological, and esthetic outcomes were recorded at distinct time points (T1; T2) at three-year intervals. RESULTS: 36 patients (18 men, 18 women) received 32 ISCs in the anterior region and 31 in the posterior region of the maxilla and mandible. The mean follow-up of the Ti-base ISCs was 6.93 ± 2.60 years. The mean follow-up of the implants amounted to 8.11 ± 3.26 years. No implants were lost during follow-up, resulting in a cumulative implant survival rate of 100%. Abutment screw loosening was observed in two ISCs after one year in service. The overall cumulative restorative survival rate of the Ti-base restorations reached thus 96.83%. At T2 follow-up 24% of the ISCs exhibited an increase in PD despite maintaining clinically healthy peri-implant tissue. An 11% increase in BOP and a 3.17% decrease in PI were recorded. Despite spectrophotometrically measured ΔE values indicating visible discoloration of some restorations and their peri-implant soft tissue, a low incidence of esthetic complications was observed with an average PES/WES score of ≥ 12. No correlation was found between PES (R = -0.25; p = 0.27) and WES (R = -0.18; p = 0.43) scores and digital shade determination. CONCLUSIONS: The results of the present retrospective, multicenter, cohort study indicate satisfactory clinical outcomes for intraorally cemented single zirconia crowns (ISCs) supported by Ti-base hybrid abutments. An overall esthetic superiority of Ti-base ISCs could not be confirmed.

11.
Int J Implant Dent ; 10(1): 33, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38935335

ABSTRACT

PURPOSE: This propensity score matching, multicenter, cross-sectional study was performed to examine the effects of various prosthetic methods for dental clinic outpatients with Kennedy Class I partial edentulism (KCIPE) on oral hypofunction, subjective frailty symptoms, and oral health-related quality of life (QOL). METHODS: Patients (n = 348) were classified into the following three groups for analysis: NT, patients with natural dentition providing intermaxillary contact in four occlusal supporting zones; RPD, patients with KCIPE who received removable partial dentures; and ISFP, patients with KCIPE who received implant-supported fixed prostheses. Participants' basic characteristics were recorded, and oral function tests were conducted. Subjective symptoms of physical and oral frailty were investigated via questionnaire. Oral health-related QOL was assessed using the Japanese short version of the Oral Health Impact Profile (OHIP-JP16). Propensity score matching was performed to adjust for patient background factors that could influence oral hypofunction in each group. RESULTS: Compared with the ISFP group, the RPD group had significantly higher rates of poor oral hygiene, reduced occlusal force, decreased masticatory function, and declines in swallowing function and oral hypofunction; the odds ratio for oral hypofunction was 4.67. Compared with the ISFP group, the RPD group had significantly greater subjective symptoms of physical frailty and oral frailty, as well as higher OHIP scores. CONCLUSIONS: Prosthetic treatment of KCIPE affected oral hypofunction, subjective frailty symptoms, and oral health-related QOL in dental clinic outpatients.


Subject(s)
Jaw, Edentulous, Partially , Oral Health , Quality of Life , Humans , Quality of Life/psychology , Cross-Sectional Studies , Male , Female , Middle Aged , Denture, Partial, Removable , Aged , Surveys and Questionnaires , Propensity Score , Dental Prosthesis, Implant-Supported , Denture, Partial, Fixed , Adult
12.
J Clin Med ; 13(12)2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38929921

ABSTRACT

Background: The improvement of oral-health-related quality of life (OHRQoL) with different types of prosthesis for completely edentulous jaws in the elderly population is a critical factor in clinical decision making for these vulnerable patients. This review aims to evaluate the changes in OHRQoL after treatment with different types of full-arch prostheses in the elderly edentulous population to determine the prostheses that result in the greatest improvement in OHRQoL. Materials and Methods: Clinical studies of different types of full-arch prostheses that measured the OHRQoL in edentulous patients 60 years or older were searched for in the PubMed, Embase and Scopus electronic databases, with additional hand searching to summarize the outcomes of the selected studies. Result: Among the 302 identified studies, 10 studies were selected. A total of 504 patients wearing 133 complete dentures, 372 implant overdentures and 39 fixed prostheses were assessed among the selected studies. The overall OHIP and GOHAI scores were evaluated at baseline and in the 3rd, 6th, 12th and 18th months of treatment with the respective prostheses. The improved OHRQoL with overall OHIP scores associated with conventional dentures were 9.21-12.5% from the 3rd month to 1 year after treatment, whereas those associated with implant overdentures and full-arch fixed prosthesis were 9-25.26% at 1 year and 18.53-26.79 at the 18th-month follow-up, respectively. The increased overall GOHAI scores were 21.3-25.43% for conventional dentures, 36.82-41.32% for implant overdentures and 39.48-42.83% for full-arch fixed prosthesis from the 3rd month to the 6th-month follow-up. Conclusion: In general, the improvement in OHRQoL after rehabilitation with implant overdentures declined at one year, and that with full-arch fixed prosthesis declined at the 18th-month follow-up; meanwhile, the OHRQoL associated with conventional dentures improved stably up to one year, but the implant-supported prostheses resulted in an obviously greater improvement in the OHRQoL than that obtained with conventional dentures. However, studies with longer follow-up periods are still required to evaluate the long-term clinical effectiveness.

13.
J Dent ; 148: 105150, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38909646

ABSTRACT

OBJECTIVES: To compare the accuracy and operative time of implant placement using a dynamic computer assisted implant surgery (dCAIS) system based on a cone beam computer tomography (CBCT) image, with and without superimposing a standard tessellation language (STL) file of an intraoral scan of the patient. METHODS: Ten identical resin models simulating an upper maxilla with posterior edentulism were assigned to two groups. In the CBCT+STL group, a CBCT file and an intraoral STL file were superimposed and used for registration; in the CBCT group, registration was performed using CBCT images. Six implants were placed in each model using the Navident® dynamic navigation system. Anatomy registration was performed by tracing fiducial points on the CBCT or STL image, depending on the group. Preoperative and postoperative CBCT images were overlaid to assess implant placement accuracy. RESULTS: Sixty implants were analyzed (30 implants in each group). 3D platform deviation was significantly lower (mean difference (MD): 0.17 mm; 95 % confidence interval (CI): 0.01 to 0.23; P = 0.039) in the CBCT+STL group (mean: 0.71 mm; standard deviation (SD): 0.29) than in the CBCT group (mean: 0.88 mm; SD: 0.39). The remaining accuracy outcome variables (angular deviation MD: -0.01; platform lateral deviation MD: 0.08 mm; apex global MD: 0.01 mm; apex depth MD: 0.33 mm) and surgery time (MD: 3.383 min.) were similar in both groups (p > 0.05). CONCLUSIONS: The introduction of an intraoral scan (STL) seems to reduce deviations slightly in dental implant placement with dCAIS systems. However, the clinical repercussion of this improvement is questionable. CLINICAL SIGNIFICANCE: Superimposing an intraoral scan on the CBCT image does not seem to increase the accuracy of dCAIS systems but can be useful when radiographic artifacts are present.

14.
Article in English | MEDLINE | ID: mdl-38829324

ABSTRACT

PURPOSE: This study aimed to evaluate the stress distribution and secondary stability involved in five implant strategies, including implant-supported prostheses (ISP) and tooth-implant-supported prostheses (TISP), used for bone atrophy in the maxillary posterior region with teeth loss using finite element analysis, and to explore the more desirable implant methods. METHODS: Five implant strategies were made to analyze and compare: M1, implant-supported prosthesis consisting of a short implant with a regular implant; M2, implant-supported prosthesis consisting of a tilted implant with a regular implant; M3, cantilever structure; M4, tooth-implant-supported prosthesis consisting of a short implant with a regular implant; M5, tooth-implant-supported prosthesis consisting of a regular implant, and M6, with only the natural teeth as a control group. Dynamic loading of the above models was performed in finite element analysis software to assess the stress distribution of the bone tissue and implants using the von Mise criterion. Finally, the secondary stability of different models was evaluated by modal analysis. RESULTS: The maximum stress distribution in the cortical bone in M1(60 MPa) was smaller than that in M2(97 MPa) and M3(101 MPa), The first principal strain minimum was obtained in M2 (2271µÎµ). M4 (33 MPa, 10085 Hz) with the best mechanical properties and highest resonance frequency. But increased the loading on the natural teeth. CONCLUSIONS: Short implants and tilted implants are both preferred implant strategies, if cantilever construction is necessary, a tooth-implant-supported prosthesis consisting of a short implant and a regular implant is recommended.

15.
Article in English | MEDLINE | ID: mdl-38822688

ABSTRACT

OBJECTIVES: To evaluate the survival rates and marginal bone loss of narrow-diameter titanium-zirconium implants supporting complete maxillary and mandibular overdentures up to 3 years after loading. MATERIALS AND METHODS: Ten completely edentulous patients who were dissatisfied with their complete dentures were enrolled. Two narrow-diameter implants were placed in the canine region of the maxilla and mandible. After second-stage surgery, implant-supported overdentures (palatal-free) attached by parallel alignable stud-attachments were placed. Patients were followed periodically for up to 36 months. Standardized radiographs were taken at baseline, 12 and 36 months to analyze mean marginal bone level changes around the implants. RESULTS: The Kaplan-Meier survival rates were 100% for mandibular and 68.0% (SE ± 10.9%) for maxillary implants at 36 months (p = .008). Six maxillary implants failed after loading; no mandibular implants were lost. Five implants failed due to loss of osseointegration. One implant fractured. The mean marginal bone level changes around the analyzed implants (n = 28, 9 patients) were -0.71 ± 0.82 mm in the mandible and -2.08 ± 1.52 mm in the maxilla at the 36-month follow-up. The difference in marginal bone level changes between the maxilla and mandible was significant (p = .019) at the 12- and 36-month follow-ups. CONCLUSION: Two narrow-diameter titanium-zirconium implants with stud-attachments showed a highly satisfactory outcome in the mandible. The maxillary implants showed a high failure rate and significantly more bone loss over time than the mandibular implants. The minimal concept of two implants and an overdenture should be limited to the edentulous mandible.

16.
Article in English | MEDLINE | ID: mdl-38884385

ABSTRACT

OBJECTIVE: To compare the implant-abutment connection microgap between computer-aided design and computer-aided manufacturing (CAD/CAM) milled or laser-sintered cobalt-chrome custom abutments with or without ceramic veneering and titanium stock abutments with or without crown cementation. MATERIAL AND METHODS: Six groups of six abutments each were prepared: (1) CAD/CAM cobalt-chrome custom abutments: milled, milled with ceramic veneering, laser-sintered, and laser-sintered with ceramic veneering (four groups: MIL, MIL-C, SIN, and SIN-C, respectively) and (2) titanium stock abutments with or without zirconia crown cementation (two groups: STK and STK-Z, respectively). Abutments were screwed to the implants by applying 30 Ncm torque. All 36 samples were sectioned along their long axes. The implant-abutment connection microgap was measured using scanning electron microscopy on the right and left sides of the connection at the upper, middle, and lower levels. Data were analyzed using the Kruskal-Wallis test (p < .05). RESULTS: Mean values (µm) of the microgap were 0.54 ± 0.44 (STK), 0.55 ± 0.48 (STK-Z), 1.53 ± 1.30 (MIL), 2.30 ± 2.2 (MIL-C), 1.53 ± 1.37 (SIN), and 1.87 ± 1.8 (SIN-C). Although significant differences were observed between the STK and STK-Z groups and the other groups (p < .05), none were observed between the milled and laser-sintered groups before or after ceramic veneering. The largest microgap was observed at the upper level in all groups. CONCLUSIONS: Titanium stock abutments provided a closer fit than cobalt-chrome custom abutments. Neither crown cementation nor ceramic veneering resulted in significant changes in the implant-abutment connection microgap.

17.
Maxillofac Plast Reconstr Surg ; 46(1): 23, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38900334

ABSTRACT

BACKGROUND: Focal and florid cemento-osseous dysplasia are benign fibro-osseous lesions affecting the quality and quantity of the jawbones. This study aimed to determine the viability of implant-based approaches in the affected patients. MAIN TEXT: Different scientific databases, including PubMed/MEDLINE, Scopus, Web of Science, Embase, the Cochrane Library, and Google Scholar, were searched until October 8, 2023, using a pre-determined search strategy. Two reviewers screened the retrieved reports and extracted the required information from the included studies. The eligibility criteria included English-language case reports/series or clinical trials. The JBI critical appraisal checklist for case reports was used to assess the methodological quality of the included studies. Three studies were deemed eligible to be included in this study out of the initial 202 records found. Five implants were placed in three patients, positioned in the proximity of the lesion area, without any additional treatment to remove the pathology. The mandibular posterior area was the affected site in all patients. Only one implant failed in one patient after 16 years, which was attributed to peri-implantitis and not the lesion. Other implants demonstrated successful maintenance over follow-up periods. CONCLUSIONS: Although the number of the included records was relatively low to draw firm conclusions, it seems that implant-based treatments in patients with focal/florid cemento-osseous dysplasia could be viable, considering a conservative and well-planned approach.

18.
Article in English | MEDLINE | ID: mdl-38860608

ABSTRACT

OBJECTIVES: The objective of this study is to analyze the clinical and radiographic outcomes of implant-supported fixed protheses with cantilever extensions (ISFPCs) in the partially edentulous anterior mandible. MATERIALS AND METHODS: Patients who received anterior mandible implant restoration between January 2016 and December 2021 were included. Patients with two, three, or four continuous missing teeth receiving adjacent implant supported single-unit crowns (ISSCs), ISFPCs, implant-supported fixed protheses without cantilever extensions (ISFPNs) were divided into groups: ISSC+ISSC, ISFPC, ISSC+ISFPC, three-unit ISFPN, ISFPC+ISFPC, or four-unit ISFPN, respectively. We recorded and evaluated survival rates, mechanical and biological complications, peri-implant marginal bone loss (MBL), esthetic outcomes, and patient perceptions. Statistical analysis was performed using linear mixed models (LMM). RESULTS: The study included 87 patients and 152 implants. No implant loss occurred during an average follow-up of 3.48 ± 1.85 years (range: 1-7 years). According to LMM models, prosthetic type had a statistically significant impact on MBL during follow-up periods, in favor of the ISFPC and ISFPC+ISFPC groups (0.16 ± 0.48 mm vs. 0.51 ± 0.49 mm, p = .034; 0.22 ± 0.49 mm vs. 0.60 ± 0.62 mm, p = .043, respectively). Mechanical and biological complications were relatively low and comparable. The four-unit ISFPC group had higher subjective esthetic scores compared with the ISSC+ISSC group (98.6 vs. 83.8, p < .05), and patients in the ISFPC+ISFPC group expressed greater satisfaction with cleanability than the ISFPN group (98.8 vs. 80.6). CONCLUSION: ISFPCs offer a highly predictable treatment option in the anterior mandible, characterized by high survival rates, and comparable complication rates, peri-implant bone stability and esthetics to adjacent ISSCs or ISFPNs.

19.
Ann Med Surg (Lond) ; 86(5): 3072-3081, 2024 May.
Article in English | MEDLINE | ID: mdl-38694351

ABSTRACT

Introduction and importance: Oligodontia is a rare genetic condition characterized by more than six congenitally missing teeth, either as an isolated non-syndromic condition or in association with other genetic syndromes. The impact of WNT10A variants on dental development increases with the presence of the c.321C>A variant and the number of missing teeth. Case presentation: A 21-year-old man with non-syndromic oligodontia was diagnosed at 15 years of age with misaligned teeth, speech problems, and the absence of 24 permanent teeth. Interdisciplinary collaboration between specialists was initiated to enable comprehensive treatment. DNA analysis confirmed that the patient was a carrier of the known pathogenic WNT10A variant c321C>A and WNT10A variant c.113G>T of unknown clinical significance. Clinical discussion: Dental implants are a common treatment; however, bone development challenges in adolescent patients with non-syndromic oligodontia necessitate careful planning to ensure implant success. Many WNT variants play crucial roles in tooth development and are directly involved in non-syndromic oligodontia, especially the WNT10 variant c.321C>A. Conclusion: A full-arch implant-supported monolithic zirconia screw-retained fixed prosthesis is a viable treatment option for young adults with non-syndromic oligodontia. Further studies are needed to clarify the possible amplifying effect of the WNT10A variants c321C>A and c.113G>T on the pathogenic phenotype of non-syndromic oligodontia.

20.
BMC Oral Health ; 24(1): 531, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38704566

ABSTRACT

BACKGROUND: Oral Health-Related Quality of Life (OHRQoL) is a comprehensive concept covering daily comfort, self-esteem, and satisfaction with oral health, including functional, psychological, and social aspects, as well as pain experiences. Despite abundant research on OHRQoL related to oral diseases and hygiene, there is limited data on how patients perceive changes after implant-prosthetic rehabilitation. This study aimed to evaluate OHRQoL and aesthetic perception using OHIP-14 and VAS scales respectively, before (baseline-TB), during (provisional prostheses-TP), and after (definitive prostheses-TD) implant-prosthetic rehabilitation. It also explored the impact of biological sex, substitution numbers, and aesthetic interventions on OHRQoL and VAS scores, along with changes in OHIP-14 domains. METHODS: A longitudinal prospective single-center observational cohort study was conducted with patients requiring implant-prosthetic rehabilitation. Quality of life relating to dental implants was assessed through the Italian version of Oral Health Impact Profile-14 (IOHIP-14), which has a summary score from 14 to 70. Patients' perceived aesthetic was analyzed through a VAS scale from 0 to 100. Generalized Linear Mixed Effect Models, Linear Mixed Effect Models, and Friedman test analyzed patient responses. RESULTS: 99 patients (35 males, 64 females) aged 61-74, receiving various prosthetic interventions, were enrolled. Both provisional and definitive prosthetic interventions significantly decreased the odds of a worse quality of life compared to baseline, with odds ratios of 0.04 and 0.01 respectively. VAS scores increased significantly after both interventions, with estimated increases of 30.44 and 51.97 points respectively. Patient-level variability was notable, with an Intraclass Correlation Coefficient (ICC) of 0.43. While biological sex, substitution numbers, and aesthetic interventions didn't significantly affect VAS scores, OHRQoL domains showed significant changes post-intervention. CONCLUSIONS: These findings support the effectiveness of implant-prosthetic interventions in improving the quality of life and perceived aesthetics of patients undergoing oral rehabilitation. They have important implications for clinical practice, highlighting the importance of individualized treatment approaches to optimize patient outcomes and satisfaction in oral health care.


Subject(s)
Dental Prosthesis, Implant-Supported , Esthetics, Dental , Oral Health , Quality of Life , Humans , Male , Female , Prospective Studies , Dental Prosthesis, Implant-Supported/psychology , Middle Aged , Aged , Longitudinal Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...