Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 268
Filter
1.
Med Clin (Barc) ; 2024 Jul 11.
Article in English, Spanish | MEDLINE | ID: mdl-38997931

ABSTRACT

Cardiac implantable electronic devices have transformed medicine as they improve quality of life and prevent premature death. In palliative care settings, deactivation of these devices must be discussed, particularly at end-of-life. In terminally ill patients it is consensual to recommend implantable cardioverter defibrillator deactivation once shocks are frequent and painful. Concerning pacemakers, the decision to deactivate is controversial and it usually is not an option at patients' end-of-life, since in pacing-dependent patients, such low heart rates might induce symptoms of bradycardia, with no impact on survival. Regarding cardiac resynchronization therapy, deactivation is not recommended as it can worsen symptoms. Left ventricular assistance device deactivation at end-of-life is a well-accepted practice, since it has the benefit of ending the physical burden associated with the device. Advance care planning should be encouraged and patients should be informed that deactivation is possible.

2.
Am J Med Sci ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-39002614

ABSTRACT

The occurrence of ventricular tachycardia (VT) in patients with acute myocardial infarction (AMI) is associated with poor prognosis. Drug therapy and implantable cardioverter-defibrillators (ICDs) are effective methods to prevent sudden death. Radiofrequency (RF) catheter ablation can map the matrix and mechanism of VT, thereby effectively reducing the occurrence of ICD discharge. This paper reports on the case of a middle-aged man who underwent emergency percutaneous coronary intervention for AMI and developed VT and ventricular fibrillation on day 7 after reperfusion. An ICD was implanted. On day 19, he received catheter ablation because of refractory monomorphic ventricular tachycardia and frequent discharge of the ICD. After three months, the patient had not experienced any further ventricular tachycardia attacks. The conclusion is that RF catheter ablation can resolve the ES after myocardial infarction and significantly reduce the occurrence of ICD discharges.

3.
Cureus ; 16(6): e61837, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38975383

ABSTRACT

Brugada syndrome (BrS) is an inherited arrhythmogenic disorder marked by distinctive ST-segment elevations on electrocardiograms (ECG) and an increased risk of sudden cardiac death. Characterized by mutations primarily in the SCN5A gene, BrS disrupts cardiac ion channel function, leading to abnormal electrical activity and arrhythmias. Although BrS primarily affects young, healthy males, it poses significant diagnostic challenges due to its often concealed or intermittent ECG manifestations and clinical presentation that can mimic other cardiac disorders. Current management strategies focus on symptom control and prevention of sudden death, with implantable cardioverter-defibrillators (ICD) serving as the primary intervention for high-risk patients. However, the complications associated with ICDs and the lack of effective pharmacological options necessitate a cautious and personalized approach. Recent advancements in catheter ablation have shown promise, particularly for managing ventricular fibrillation (VF) storms and reducing ICD shocks. Additionally, pharmacological treatments such as quinidine have been effective in specific cases, though their use is limited by availability and side effects. This review highlights significant gaps in the BrS literature, particularly in terms of long-term management and novel therapeutic approaches. The importance of genetic screening and tailored treatment strategies to better identify and manage at-risk individuals is emphasized. The review aims to enhance the understanding of BrS and improve patient outcomes, advocating for a multidisciplinary approach to this complex syndrome.

4.
Rev. esp. cardiol. (Ed. impr.) ; 77(5): 362-369, mayo 2024. ilus, tab, graf
Article in Spanish | IBECS | ID: ibc-JHG-67

ABSTRACT

Introducción y objetivos: La experiencia con el desfibrilador automático implantable subcutáneo (DAI-SC) en pacientes pediátricos aún es reducida. El objetivo de este estudio es determinar la incidencia de complicaciones en pacientes pediátricos de nuestro centro en función del tipo de DAI y del tamaño del paciente.MétodosSe incluyó a pacientes menores de 18 años que recibieron un DAI-SC desde 2016 y pacientes contemporáneos (desde 2014) que recibieron un DAI transvenoso (DAI-TV). El evento principal fue el combinado de complicaciones y descargas inapropiadas.ResultadosSe implantó un DAI-SC a 26 pacientes (edad, 14 [intervalo, 5-17] años; índice de masa corporal [IMC], 20,2). De ellos, 23 (88%) fueron implantes intermusculares y el resto, en subserrato, 24 (92%) con 2 incisiones. Se programaron 2 zonas en todos los pacientes: condicional a 230 (220-230) lpm y de choque a 250 lpm. El grupo de DAI-TV incluyó a 19 pacientes (edad, 11 [5-16] años; IMC, 19,2; el 79% monocamerales). La supervivencia libre del evento principal a 5 años fue el 80% de los pacientes con DAI-SC y el 63% del grupo con DAI-TV (p=0,54); la de descargas inapropiadas fue similar (el 85 frente al 89%; p=0,86), mientras que la de complicaciones fue mayor en el grupo de DAI-SC (el 96 frente al 57%; cloglog p=0.016). En el grupo de DAI-SC no hubo fallo de la terapia ni mayores complicaciones con un IMC ≤ 20.ConclusionesCon las técnicas de implante y programación actuales, el DAI-SC es eficaz y seguro en pacientes pediátricos, con similares descargas inapropiadas y menos complicaciones a corto y medio plazo que el DAI-TV. (AU)


Introduction and objectives: There is limited evidence regarding the use of subcutaneous implantable cardioverter-defibrillators (S-ICD) in pediatric patients. The aim of this study was to determine the incidence of complications in these patients at our center, according to the type of ICD and patient size.MethodsWe included all patients aged<18 years who received an S-ICD since 2016 at our center. As a control group, we also included contemporary patients (since 2014) who received a transvenous ICD (TV-ICD). The primary endpoint was a composite of complications and inappropriate shocks.ResultsA total of 26 patients received an S-ICD (median age, 14 [5-17] years; body mass index [BMI], 20.2 kg/m2). Implantation was intermuscular in 23 patients (88%) and subserratus in the remainder. Two incisions were used in 24 patients (92%). In all patients, 2 zones were programmed: a conditional zone set at 230 (220-230) bpm, and a shock zone set at 250 bpm. Nineteen patients received a TV-ICD (median age, 11 [range, 5-16] years; BMI, 19.2 kg/m2, 79% single-chamber). Survival free from the primary endpoint at 5 years was 80% in the S-ICD group and 63% in the TV-ICD group (P=.54). Survival free from inappropriate shocks was similar (85% vs 89%, P=.86), while survival free from complications was higher in the S-ICD group (96% vs 57%, cloglogP=.016). There were no therapy failures in the S-ICD group, and no increased complication rates were observed in patients with BMI ≤ 20 kg/m2.ConclusionsWith contemporary implantation techniques and programming, S-ICD is a safe and effective therapy in pediatric patients. The number of inappropriate shocks is similar to TV-ICD, with fewer short- and mid-term complications. (AU)


Subject(s)
Humans , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Follow-Up Studies , Incidence
5.
Heart Rhythm ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38762820

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators last longer, and interest in reliable leads with targeted lead placement is growing. The OmniaSecure™ defibrillation lead is a novel small-diameter, catheter-delivered lead designed for targeted placement, based on the established SelectSecure SureScan MRI Model 3830 lumenless pacing lead platform. OBJECTIVE: This trial assessed safety and efficacy of the OmniaSecure defibrillation lead. METHODS: The worldwide LEADR pivotal clinical trial enrolled patients indicated for de novo implantation of a primary or secondary prevention implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator, all of whom received the study lead. The primary efficacy end point was successful defibrillation at implantation per protocol. The primary safety end point was freedom from study lead-related major complications at 6 months. The primary efficacy and safety objectives were met if the lower bound of the 2-sided 95% credible interval was >88% and >90%, respectively. RESULTS: In total, 643 patients successfully received the study lead, and 505 patients have completed 12-month follow-up. The lead was placed in the desired right ventricular location in 99.5% of patients. Defibrillation testing at implantation was completed in 119 patients, with success in 97.5%. The Kaplan-Meier estimated freedom from study lead-related major complications was 97.1% at 6 and 12 months. The trial exceeded the primary efficacy and safety objective thresholds. There were zero study lead fractures and electrical performance was stable throughout the mean follow-up of 12.7 ± 4.8 months (mean ± SD). CONCLUSION: The OmniaSecure lead exceeded prespecified primary end point performance goals for safety and efficacy, demonstrating high defibrillation success and a low occurrence of lead-related major complications with zero lead fractures.

6.
Int J Cardiol Cardiovasc Risk Prev ; 21: 200255, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38737437

ABSTRACT

Aim: The aim is to discuss efficacy and safety of exercise-based cardiac rehabilitation (CR) programmes in participants with implantable cardiac devices compared with usual care. Methods: MEDLINE, EMBASE and Cochrane databases were searched from inspection till July 15, 2022. Randomized controlled trials were included if they enrolled adult participants with implantable cardiac devices and tested exercise-based CR interventions in comparison with any control. Risk of bias was assessed, and endpoints data were pooled using random-effects model. Results: Sixteen randomized trials enrolling 2053 participants were included. Study interventions differed between studies in terms of programme components, setting, exercise intensity, and follow-up. All studies included physical exercise component. In both implantable cardioverter defibrillators (ICD) and cardiac resynchronization therapy (CRT) groups, exercise training in CR programmes improved peak oxygen uptake (VO2) [(mean difference (MD) 2.08 ml/kg/min; 95 % CI: 1.44-2.728, p < 0.0001; I2 = 99 %) and (MD 2.24 ml/kg/min; 95 % CI: 1.43-3.04, p < 0.0001; I2 = 96 %), respectively] and 6-min walk test in ICD group (MD 41.51 m; 95 % CI: 15.19-67.82 m, p = 0.002; I2 = 95 %) compared with usual care. In CRT group, there was no statistically significant improvement in left ventricular ejection fraction change between comparison groups. The results were consistent in subgroup analysis according to high or low-to-moderate exercise intensity for change in peak VO2 and ejection fraction in CRT group. There was no difference in number of ICD shocks between the comparators. Conclusion: Exercise-based CR programmes appear to be safe when enrolling participants with implantable cardiac devices and leading to favourable functional outcomes.

7.
ESC Heart Fail ; 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741255

ABSTRACT

Implantable cardioverter defibrillators (ICDs) reliably prevent death due to life-threatening arrhythmias; this may become less relevant in people with more severe heart failure who are reaching the end of life (EOL). This review aimed to explore the ICD deactivation process and identify ethical issues, especially around the initiation of relevant discussions among professionals and patients. Available literature was reviewed using four electronic databases to identify issues that may deter healthcare professionals from having important deactivation discussions and to address considerations for ICD management prior to the EOL. The search resulted in the retainment of 12 studies. Three themes emerged from the data: barriers and facilitators, ethical considerations in clinical practice, and nurse's role. Lack of knowledge, which has been associated with cultural differences, has been found among the barriers, and interdisciplinary education and open communication appeared as facilitators. As clinicians' ethical considerations and fears emerged from the literature, nurses' special role has not been sufficiently supported. Complex care requires facilitation by multidisciplinary teams and education around the device's function regarding EOL issues. Establishing expert consensus statements on advance care planning might help define the distinct roles of each healthcare practitioner involved. Further research is needed in addressing the identified gaps.

8.
Heart Lung ; 67: 152-157, 2024.
Article in English | MEDLINE | ID: mdl-38762963

ABSTRACT

BACKGROUND: Support groups for people with Implantable Cardioverter Defibrillators (ICDs) are widely used, however, it is not clear what people with ICDs gain from a support group or what format they should take. OBJECTIVES: The aim of the present study is to define the perceived benefit of ICD support groups and develop practical recommendations for group format. METHODS: 14 individuals with ICDs were interviewed using a semi-structured interview guide. Reflexive thematic analysis methods were utilised to code and analyse the transcripts before generating themes. RESULTS: Four themes were defined: confronting mortality, coping through sharing, coping through learning, and providing space. Making connections with other people with ICDs, reassurance, access to information, and advice from health care professionals were important perceived benefits of the support group. CONCLUSION: People with ICDs may have to confront their own mortality and adapt to considerable life changes after implant. The findings from the present study have improved understanding of how support groups are perceived and how ICD indication and group format influence the experience. A blended format of in-person community meetings, online forums, HCP-led education and space for person-person interaction is recommended. Importantly, provision of support should not be time-limited to allow people to access it when it most likely to be of benefit to them.


Subject(s)
Adaptation, Psychological , Defibrillators, Implantable , Self-Help Groups , Humans , Defibrillators, Implantable/psychology , Male , Female , Middle Aged , Aged , Adult , Social Support , Qualitative Research
9.
Herzschrittmacherther Elektrophysiol ; 35(2): 155-164, 2024 Jun.
Article in German | MEDLINE | ID: mdl-38748284

ABSTRACT

The implantation of electrodes for cardiac implantable electronic devices (CIED) requires profound technical understanding and precise execution. The positioning of electrodes in the right ventricle and atrium has significant implications for patient safety and the effectiveness of CIED therapy. Particular focus is given to the distinction between apical and septal stimulation in ventricular positioning. Based on current data, this article provides a practice-oriented guide that leads implanters through the individual steps of electrode positioning. The implantation of electrodes for physiological stimulation (cardiac resynchronization therapy, CRT, and conduction system pacing, CSP) is not addressed in this article.


Subject(s)
Cardiac Surgical Procedures , Electrodes, Implanted , Humans , Evidence-Based Medicine , Prosthesis Implantation/methods , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods
10.
Heart Rhythm O2 ; 5(3): 168-173, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38560378

ABSTRACT

Background: Limited real-world evidence exists for outcomes with contemporary guideline-directed medical therapy (GDMT) or GDMT with implantable cardioverter-defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) therapy for patients with heart failure with reduced ejection fraction (HFrEF) and left ventricular ejection fraction (LVEF) ≤35%. Objective: The present study aimed to assess survival associated with GDMT or GDMT with ICD/CRT-D therapy. Methods: This retrospective observational study included real-world de-identified data from January 1, 2016, to December 19, 2023, from 24 U.S. institutions per participating institutional agreements (egnite Database; egnite, Inc.). Patients with a diagnosis of HFrEF and an echocardiographic study documenting LVEF ≤35% were included for analysis. Results: Of 43,591 patients with eligible index event of LVEF ≤35%, prescription history through ≥1 year preindex, and no ICD/CRT-D therapy preindex, mean ± standard deviation age at index was 71.2 ± 13.2 years; 14,805 (34.0%) patients were female. At 24 months, an estimated 99.1% (95% confidence interval [CI] 99.0%-99.2%), 89.9% (95% CI 89.7%-90.1%), 54.8% (95% CI 54.4%-55.2%), and 17.2% (95% CI 16.9%-17.5%), had ≥1, 2, 3, or all 4 GDMT classes prescribed, respectively; an estimated 15.7% (95% CI 15.3%-16.1%) had device placement. Of those without a device, by 24 months, an estimated 45.1% (95% CI 44.4%-45.7%) had a documented LVEF >35%. Counts of GDMT classes prescribed as well as ICD/CRT-D device therapy were associated with lower mortality risk in this population, even after adjustment for patient age, sex, and comorbidities. Conclusion: Both GDMT classes prescribed and device therapy were independently associated with lower mortality risk, even in the presence of more GDMT options for this more contemporary population.

11.
J Thorac Dis ; 16(3): 1825-1835, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38617758

ABSTRACT

Background: Atrial fibrillation (AF) is a cardiac arrhythmia frequently documented in patients requiring implantable cardioverter defibrillators (ICDs) and/or cardiac resynchronization therapy with defibrillator (CRT-D). Patients with diagnosed AF at the point of ICD or CRT-D implantation may have an impaired follow-up outcome. Methods: The German DEVICE I-II registry is a nationwide prospective multicentre database of patients implanted with ICD and CRT-D with clinical follow-up data. We analysed a 1-year follow up of implanted patients with AF and with sinus rhythm (SR). Results: A total of 4,929 ICD/CRT patients are included in the present analysis: 946 (19.2%) were in AF and 3,983 (80.8%) were SR at time of device implantation. AF patients had a significantly more comorbid profile including older age {72 [interquartile range (IQR), 66-77] vs. 66 (IQR, 56-73) years; P<0.001}, and higher rate of patients with left ventricular ejection fraction <30% (68.2% vs. 61.0%; P<0.001), peripheral artery disease (4.5% vs. 2.7%; P=0.002), diabetes (33.6% vs. 25.5%; P<0.001), hypertension (58.4% vs. 51.1%; P<0.001) and renal failure (22.6% vs. 15.3%; P<0.001). The intra-hospital complication rate was 4.3% in the AF and 3.6% in the SR group (P=0.38). In 1-year follow-up AF patients experienced a significantly higher rate of defibrillator shocks (25% vs. 15.3%; P<0.001). One-year estimated mortality was 10.8% in the AF and 5.9% in the SR group (P<0.001), while estimated 1-year major adverse cardiac and cerebrovascular events (MACCE) rate was 11.2% vs. 7.0% (P<0.001). The effects of AF on electrical shocks and mortality persisted after adjusting for age, sex, advanced New York Heart Association (NYHA) class, severely impaired left ventricular ejection fraction (LVEF), coronary artery disease (CAD), chronic obstructive pulmonary disease (COPD), diabetes mellitus (DM), chronic renal failure (CRF), QRS duration, and type of indication for electronic device implantation. Conclusions: Our clinical data on an extended cohort of contemporary patients confirm the significant impact of AF, and its associated comorbidities, upon mortality and major adverse events after implantation of ICD/CRT.

12.
Pacing Clin Electrophysiol ; 47(5): 697-701, 2024 May.
Article in English | MEDLINE | ID: mdl-38597183

ABSTRACT

BACKGROUND: Patients ≥80 with implantable cardioverter-defibrillators (ICDs) have high rates of hospitalization and mortality, yet few have documented advance directives. We sought to determine the prevalence of advance directives in adults ≥80 years with ICDs, focusing on those with frailty and cognitive impairment. METHODS: Prospective cohort study (July 2016-May 2019) in an electrophysiology clinic. Presence of advance directives (health care proxies [HCP] and living wills [LW], or medical orders for life-sustaining treatment [MOLST]) was determined by medical record review. Frailty and cognitive impairment were screened using 4-m gait speed and Mini-Cog. RESULTS: 77 Veterans were evaluated. Mean age 84 years, 100% male, 70% frail. Overall, 52 (68%) had an HCP and 37 (48%) had a LW/MOLST. Of 67 with cognitive testing, 36% were impaired. HCP documentation was similar among frail and non-frail (69% vs. 65%). LW/MOLST was more prevalent among frail versus non-frail (52% vs. 39%). There was no difference in HCP documentation by cognitive status (67%). A LW/MOLST was more frequent for cognitively impaired versus non-impaired (50% vs. 42%). Among 19 Veterans who were frail and cognitively impaired, 14 (74%) had an HCP and 11 (58%) had a LW/MOLST. CONCLUSIONS: Most Veterans had a documented advance directive, but a significant minority did not. Simple frailty and cognitive screening tools can rapidly identify patients for whom discussion of advance directives is especially important.


Subject(s)
Advance Directives , Defibrillators, Implantable , Humans , Male , Female , Aged, 80 and over , Prospective Studies , Cognitive Dysfunction , Frailty
13.
ESC Heart Fail ; 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38491741

ABSTRACT

Obesity condition causes morphological and functional alterations involving the cardiovascular system. These can represent the substrates for different cardiovascular diseases, such as atrial fibrillation, coronary artery disease, sudden cardiac death, and heart failure (HF) with both preserved ejection fraction (EF) and reduced EF. Different pathogenetic mechanisms may help to explain the association between obesity and HF including left ventricular remodelling and epicardial fat accumulation, endothelial dysfunction, and coronary microvascular dysfunction. Multi-imaging modalities are required for appropriate recognition of subclinical systolic dysfunction typically associated with obesity, with echocardiography being the most cost-effective technique. Therapeutic approach in patients with obesity and HF is challenging, particularly regarding patients with preserved EF in which few strategies with high level of evidence are available. Weight loss is of extreme importance in patients with obesity and HF, being a primary therapeutic intervention. Sodium-glucose co-transporter-2 inhibitors have been recently introduced as a novel tool in the management of HF patients. The present review aims at analysing the most recent studies supporting pathogenesis, diagnosis, and management in patients with obesity and HF.

14.
J Pain Symptom Manage ; 67(5): e409-e415, 2024 May.
Article in English | MEDLINE | ID: mdl-38331233

ABSTRACT

BACKGROUND: Implantable cardioverter defibrillators (ICDs) decrease mortality in high-risk patients but can also cause distressing shocks near death. Patients who lack knowledge about their ICDs are more likely to have an active device at the end of life. Many hospice workers lack sufficient knowledge to educate patients about ICDs. MEASURES: An ICD educational video created for use in a diverse, underserved patient population was shown to hospice workers from two large community hospices and attendees of a regional conference. A validated 10 question survey was given to participants before and after the video. OUTCOMES: Significant improvement in ICD knowledge scores was seen in all participants (W = 3119.5, P < 0.0001). While doctors and nurses showed higher pretest knowledge, post-test knowledge scores equalized across all participants. CONCLUSIONS/LESSONS LEARNED: An ICD patient educational video designed for a diverse, underserved patient population effectively improved ICD knowledge to a uniform excellent level for a broad range of hospice workers.


Subject(s)
Defibrillators, Implantable , Hospice Care , Hospices , Humans , Death
15.
J Gen Intern Med ; 39(Suppl 1): 87-96, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38252247

ABSTRACT

BACKGROUND: Remote monitoring (RM) of pacemakers and implantable cardioverter-defibrillators (ICDs) reduces morbidity and mortality. However, many patients are not adherent to RM. OBJECTIVE: To test the effect of informational postcards on RM adherence. DESIGN/PATIENTS: Stepped-wedge randomized controlled trial among Veterans with pacemakers and ICDs. INTERVENTION: In wave 1, Veterans who had sent at least 1 transmission within the past 2 years but had become non-adherent were randomly assigned to receive a postcard or no postcard. Those receiving postcards were randomized to 1 of 2 messages: (1) a"warning" postcard describing risks of non-adherence or (2) an "encouraging" postcard describing benefits of adherence. In wave 2, Veterans who had either not received a postcard in wave 1 or had since become non-adherent were mailed a postcard (again, randomized to 1 of 2 messages). Patients who did not send an RM transmission within 1 month were mailed a second, identical postcard. MAIN MEASURES: Transmission within 70 days. KEY RESULTS: Overall, 6351 Veterans were included. In waves 1 and 2, postcards were mailed to 5657 Veterans (2821 "warning" messages and 2836 "encouraging" messages). Wave 1 included 2178 Veterans as controls (i.e., not mailed a postcard), some of whom received a postcard in wave 2 if they remained non-adherent. In wave 2, 3473 postcards were sent. Of the 5657 patients mailed a postcard, 2756 (48.7%) sent an RM transmission within 70 days, compared to 530 (24.3%) of 2178 controls (absolute difference 24.4%, 95% confidence interval [CI] 22.2%, 26.6%). Of those who sent a transmission, 71.8% did so after the first postcard. Transmission rates at 70 days did not significantly differ between "warning" and "encouraging" messages (odds ratio 1.04, 95% CI 0.92, 1.18). CONCLUSIONS: Informational postcards led to a 24.4% absolute increase in adherence at 70 days among Veterans with pacemakers and ICDs who were non-adherent to RM.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Veterans , Humans
16.
Prim Care ; 51(1): 143-154, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38278568

ABSTRACT

Ventricular tachyarrhythmias remain a major cause of sudden cardiac arrest (SCA) that leads to sudden cardiac death (SCD). Primary prevention strategies to prevent SCD include promoting a healthy lifestyle, following United States Preventive Service Task Force recommendations related to cardiovascular disease, and controlling comorbid conditions. For a patient experiencing SCA, early cardiopulmonary resuscitation and defibrillation should be performed. Implantable cardioverter defibrillators are more effective at secondary prevention compared with drug therapy but medications such as amiodarone, beta-blockers, and sotalol may be helpful adjuncts to reduce the risk of SCD or improve a patient's symptoms (eg, palpitations and inappropriate defibrillator shocks).


Subject(s)
Defibrillators, Implantable , Heart Arrest , Humans , Arrhythmias, Cardiac/therapy , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Heart Arrest/complications , Defibrillators, Implantable/adverse effects , Sotalol
18.
Pacing Clin Electrophysiol ; 47(2): 312-320, 2024 02.
Article in English | MEDLINE | ID: mdl-38140904

ABSTRACT

BACKGROUND: Sudden cardiac death (SCD) risk markers are needed in Chagas cardiomyopathy (CC). Action potential duration restitution (APDR) dynamics is capable of extracting information on cardiac regional heterogeneity. This study intends to develop a patient-specific variables-based algorithm to predict SCD in the low-intermediate subgroups of the Rassi risk score. METHODS: Cross-sectional study of patients who underwent 24-h Holter for research purposes between January 1992 and February 2017. From 4-h ECG segment, RR series were generated and APDR dynamics metrics were calculated. Classification tree and sensitivity analysis were applied. As outcomes, SCD, SCD-free and non-cardiovascular death and 34 variables were included. RESULTS: Two hundred twenty-one (129 in the group SCD-free, 80 in the SCD group and 12 non-cardiovascular death group) were analyzed. In the groups with and without SCD (209 patients), the median age was 66 years, 52% were female, the cardiac involvement was mild to moderate in 72% with a Rassi point median of 8 (IQ: 3 to 11). The SCD group had more ventricular remodeling and more ventricular electrical instability. The occurrence of a %beats QTend/TendQ ratio > 1 (AUC, 0.96 (95% CI 0.89-0.98) present in more than 56.7% of the 4-h ECG segments was sufficient to identify patients of the SCD subgroup. Variables representing different stages of CC were also relevant in the model. CONCLUSION: It is possible to use APDR dynamics as an adjuvant in the SCD risk assessment in a subgroup of patients with a high risk of SCD and a very low risk of non-CV death with high power of discrimination.


Subject(s)
Chagas Cardiomyopathy , Defibrillators, Implantable , Humans , Aged , Stroke Volume/physiology , Ventricular Function, Left , Chagas Cardiomyopathy/complications , Cross-Sectional Studies , Death, Sudden, Cardiac/epidemiology , Risk Factors , Risk Assessment
19.
Int J Cardiol Heart Vasc ; 49: 101312, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38076344

ABSTRACT

Objectives: Data on anesthetic proceedings during cardiac implantable electronic device (CIED) implant procedures are scarce and it remains unclear whether anesthetic care is still required in selected patients. Methods: In this retrospective, single center study we assessed the prevalence of intraoperative anesthetic management comprising anesthetic standby, sedation or general anesthesia as well as anesthetic and procedural complications. We analyzed pre-existing and perioperative risk factors related to procedure-related adverse outcome such as perioperative cardiopulmonary resuscitation (CPR) and 30-day mortality in a uni- and multivariable analysis. Results: In total, PM and ICD insertion were performed in up to 85% and 58% under anesthetic standby, with an increasing tendency over time.Overall, Cardiopulmonary resuscitation (CPR) was required in 59 patients. Acute heart failure (AHF) was the only independent pre-existing risk factor for CPR and for 30-day mortality. Sedation and general anesthesia had a significantly increased odds ratio for CPR compared to anesthetic standby. The risk for CPR significantly decreased during the study period. Conclusions: Over the years anesthetic practice during CIED implant procedures shifted from mixed anesthetic proceedings to mainly standby duties. The prevalence of complications and emergency measures is low, however not uncommon. Accordingly, the presence of an anesthesiologist should be further guaranteed when sedatives were titrated and in AHF patients. However, in patients receiving local anesthetic infiltration only, it seems safe to perform CIED implant procedures without anesthetic standby.

20.
Intern Med J ; 53(11): 1956-1962, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37929818

ABSTRACT

Secondary prevention implantable cardioverter defibrillators (ICDs) are indicated in young patients presenting with aborted sudden cardiac death (SCD) because of ventricular arrhythmias. Transvenous-ICDs (TV-ICDs) are effective, established therapies supported by evidence. The significant morbidity associated with transvenous leads led to the development of the newer subcutaneous-ICD (S-ICD). This review discusses the clinical considerations when selecting an ICD for the young patient presenting with out-of-hospital cardiac arrest. The major benefits of TV-ICDs are their ability to pace (antitachycardia pacing [ATP], bradycardia support and cardiac resynchronisation therapy [CRT]) and the robust evidence base supporting their use. Other benefits include a longer battery life. Significant complications associated with transvenous leads include pneumothorax and tamponade during insertion and infection and lead failure in the long term. Comparatively, S-ICDs, by virtue of having no intravascular leads, prevent these complications. S-ICDs have been associated with a higher incidence of inappropriate shocks. Patients with an indication for bradycardia pacing, CRT or ATP (documented ventricular tachycardia) are seen as unsuitable for a S-ICD. If venous access is unsuitable or undesirable, S-ICDs should be considered given the patient is appropriately screened. There is a need for further randomised controlled trials to directly compare the two devices. TV-ICDs are an effective therapy for preventing SCD limited by significant lead-related complications. S-ICDs are an important development hindered largely by an inability to pace. Young patients stand to gain the most from a S-ICD as the cumulative risk of lead-related complications is high. A clinical framework to aid decision-making is presented.


Subject(s)
Defibrillators, Implantable , Heart Arrest , Humans , Defibrillators, Implantable/adverse effects , Bradycardia , Arrhythmias, Cardiac , Heart Arrest/therapy , Adenosine Triphosphate , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/epidemiology , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...