Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 992
Filter
1.
Article in English | MEDLINE | ID: mdl-38959377

ABSTRACT

BACKGROUND: The treatment of resistant coronary lesions (RCL) is a great challenge for interventional cardiologists. The excimer laser coronary atherectomy (ELCA) is a plaque modification tool based on a main mechanism of photomechanical effect leading to mechanical disruption of the plaque. Contrast dye injection during laser delivery has demonstrated to enhance its power. AIM: To evaluate the effectiveness and safety of the contrast-enhanced ELCA by a stepwise approach in the treatment of RCLs. METHODS: We retrospectively examined consecutive patients undergoing contrast-enhanced ELCA-assisted PCI between 2018 and 2021 at two Italian sites. RCLs were defined as novo or in-stent undilatable/uncrossable with conventional balloons (SC/NC balloon). The primary endpoint was ELCA technical success defined as the laser catheter crossing the entire length of the target lesion established by angiographic evidence of the catheter tip in the artery distal to the stenosis. RESULTS: We enrolled 114 patients who underwent contrast-enhanced ELCA-assisted PCI: 58% of the patients had acute coronary syndrome while the left anterior descending artery was the target vessel in 42.1% of cases. The target lesion was most commonly in-stent (56.2%). The 0.9 mm ELCA catheter tip was employed in 89.5% of cases. The most used frequency/fluency profile was 70/70 (39.5%). The use of contrast-enhanced ELCA was associated with high technical, procedural, and clinical success rates (97.4%, 93.7%, and 90.1%, respectively). CONCLUSIONS: The contrast-enhanced ELCA seems to be a safe and effective treatment option for the management of both de novo and in-stent-resistant coronary lesions.

2.
J Cardiovasc Dev Dis ; 11(6)2024 May 22.
Article in English | MEDLINE | ID: mdl-38921660

ABSTRACT

We characterized the performance, as well as the safety, of a second-generation thin-strut sirolimus-eluting stent with a biodegradable polymer, Alex Plus (Balton, Poland), implanted in patients with type 2 diabetes (DM) with a 4-year follow-up. We defined the primary endpoint as the 48-month rate of major cardiovascular adverse events (MACE), including cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR). The secondary endpoints were all-cause death, cardiac death, MI, and TLR rates at 12, 24, 36, and 48 months. We enrolled 232 patients in whom 282 stents were implanted, including 97 DM and 135 non-DM patients. The mean age of the DM patients was 69.5 ± 10.1 years and females accounted for 30% of the patients. DM patients had higher rates of arterial hypertension (97% vs. 88%, p = 0.016), dyslipidemia (86% vs. 70%, p = 0.005), prior MI (61% vs. 40%, p = 0.002), prior PCI (65% vs. 50%, p = 0.020), and prior CABG (14% vs. 5.9%, p = 0.029). We recorded statistically significant differences for MACE (HR 1.85, 95% CI 1.01-3.41, p = 0.046), cardiac death (HR 4.46, 95% CI 1.44-13.8, p = 0.010), and MI (HR 3.17, 95% CI 1.10-9.12, p = 0.033), but not for TLR, between DM and non-DM patients in terms of the analyzed endpoints at 4 years. Our study showed that Alex Plus was efficient and safe in a contemporary cohort of real-world DM patients undergoing percutaneous revascularization.

3.
Eur J Prev Cardiol ; 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38916491

ABSTRACT

AIM: Lipoprotein(a) [Lp(a)] has demonstrated its association with atherosclerosis and myocardial infarction. However, its role in the development of in-stent restenosis (ISR) after percutaneous coronary intervention (PCI) is not clearly established. The aim of this study is to investigate the association between Lp(a) and ISR. METHODS: A retrospective study of adult patients who underwent successful PCI between January 2006 and December 2017 at the three Mayo Clinic sites and had a preprocedural Lp(a) measurement was conducted. Patients were divided into two groups according to the serum Lp(a) concentration (high Lp(a) ≥50 mg/dl and low Lp(a) <50 mg/dl). Univariable and multivariable analyses were performed to compare risk of ISR between patients with high Lp(a) versus those with low Lp(a). RESULTS: A total of 1209 patients were included, with mean age 65.9 ±11.7 years and 71.8% were male. Median follow-up after baseline PCI was 8.8 (IQR 7.4) years. Restenosis was observed in 162 (13.4%) patients. Median serum levels of Lp(a) were significantly higher in patients affected by ISR versus non-affected cases: 27 (IQR 73.8) vs. 20 (IQR 57.5) mg/dL, p=0.008. The rate of ISR was significantly higher among patients with high Lp(a) versus patients with low Lp(a) values (17.0% vs 11.6%, p=0.010). High Lp(a) values were independently associated with ISR events (HR 1.67, 95%CI 1.18 to 2.37, p=0.004), and this association was more prominent after the first year following the PCI. CONCLUSION: Lipoprotein(a) is an independent predictor for long-term in-stent restenosis and should be considered in the evaluation of patients undergoing PCI.


The role of Lp(a) in the development of in-stent restenosis is not clearly established. In this study including 1209 patients who underwent successful percutaneous coronary intervention and had a preprocedural Lp(a) measurement between 2006 and 2017, the rates of restenosis were significantly higher among patients with high Lp(a) versus patients with low Lp(a) values and high Lp(a) concentrations were independently associated with restenosis events. Lp(a) should be considered as a risk factor for long term in-stent restenosis in the evaluation of patients undergoing percutaneous coronary intervention and assessed as a potential therapeutic target for reducing residual cardiovascular risk in this population.

4.
Adv Healthc Mater ; : e2401545, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38924692

ABSTRACT

While blood-contacting materials are widely deployed in medicine in vascular stents, catheters, and cannulas, devices fail in situ because of thrombosis and restenosis. Furthermore, microbial attachment and biofilm formation is not an uncommon problem for medical devices. Even incremental improvements in hemocompatible materials can provide significant benefits for patients in terms of safety and patency as well as substantial cost savings. Herein, a novel but simple strategy is described for coating a range of medical materials, that can be applied to objects of complex geometry, involving plasma-grafting of an ultrathin hyperbranched polyglycerol coating (HPG). Plasma activation creates highly reactive surface oxygen moieties that readily react with glycidol. Irrespective of the substrate, coatings are uniform and pinhole free, comprising O─C─O repeats, with HPG chains packing in a fashion that holds reversibly binding proteins at the coating surface. In vitro assays with planar test samples show that HPG prevents platelet adhesion and activation, as well as reducing (>3 log) bacterial attachment and preventing biofilm formation. Ex vivo and preclinical studies show that HPG-coated nitinol stents do not elicit thrombosis or restenosis, nor complement or neutrophil activation. Subcutaneous implantation of HPG coated disks under the skin of mice shows no evidence of toxicity nor inflammation.

5.
Front Neurol ; 15: 1360609, 2024.
Article in English | MEDLINE | ID: mdl-38841701

ABSTRACT

Background: Symptomatic intracranial in-stent restenosis (sISR) poses a major challenge in the management of cerebrovascular diseases, often requiring effective and safe treatment options. Objectives: This study aims to evaluate the efficacy and safety of paclitaxel-coated balloon (PCB) angioplasty for treating sISR. Methods: We conducted a retrospective analysis of five patients aged 49-74 years, who were treated with PCB angioplasty between January 2017 and June 2022. Treatment procedures included pre-operative digital subtraction angiography, antiplatelet therapy, and the use of the SeQuent Please balloon. Patients received aspirin and clopidogrel prior to and after the procedure. Results: The procedure achieved a 100% success rate. The degree of ISR was significantly reduced from an average pre-operative rate of 72±18.9% to a post-operative rate of 34±8.22%. Long-term follow-up showed that the majority of patients did not experience restenosis, confirming the long-term effectiveness of the treatment. Conclusions: PCB angioplasty demonstrates significant potential as an effective and safe treatment option for patients with sISR, especially those considered to be at high risk. This study supports further investigation into PCB angioplasty as a standard treatment for sISR.

6.
Article in English | MEDLINE | ID: mdl-38845281

ABSTRACT

Since the advent of coronary stents, two of the most common long-term complications after percutaneous coronary intervention (PCI) are in-stent restenosis (ISR) and stent thrombosis (ST). Although the rates of ST have been nearly abolished and ISR rates have declined with the current gold-standard second-generation drug-eluting stents (DES), late ISR of DES remains a valid concern in the field of interventional cardiology. The drug-coated balloon (DCB) is a non-stent technology that relies on the concept of targeted homogeneous drug delivery from an inflated balloon to restore luminal vascularity, treat atherosclerosis, and overcome some limitations of PCI, including ISR and prolonged dual antiplatelet therapy to prevent ST by leaving nothing behind. Most clinical evidence on coronary DCBs predominantly comes from small, randomized data and registries using paclitaxel DCBs for ISR and de novo lesions in the coronary space. Since 2014, outside the United States, DCBs have been approved for the treatment of ISR, with a class I recommendation by the European Society of Cardiology. The Food and Drug Administration very recently approved the Agent DCB to treat ISR in patients with coronary artery disease in the US. Additionally, recent randomized clinical data also showed DCB's safety and efficacy for the treatment of de novo small-vessel disease and high-bleeding-risk patients, while their role for other clinical situations including acute coronary syndrome, large-vessel disease, bifurcation lesions, and long-diffuse distal lesions is currently under investigation. Herein, we review the evidence-based role of DCBs in the treatment of coronary lesions and offer future perspectives.

7.
Neurologia (Engl Ed) ; 39(6): 449-456, 2024.
Article in English | MEDLINE | ID: mdl-38901925

ABSTRACT

PURPOSE: This study aimed to investigate the effectiveness and safety of endovascular revascularisation of intracranial artery occlusion and stenosis in moyamoya disease using stent angioplasty. MATERIALS AND METHODS: We recruited 12 patients (8 women and 4 men) with occlusion and stenosis of intracranial arteries in the context of moyamoya disease who underwent endovascular stent angioplasty. Clinical data, baseline conditions, lesion location, treatment outcomes, periprocedural complications, and follow-up outcomes were analysed. RESULTS: The occlusion was located at the M1 segment of the middle cerebral artery in 8 patients, at both the M1 and A2 segments in one patient, and at the C7 segment of the internal carotid artery in 3. Thirteen stents were deployed at the occlusion site, including the low-profile visualized intraluminal support (LVIS) device in 8 patients, an LVIS device and a Solitaire AB stent in one, and a Leo stent in 3, with a success rate of 100% and no intraprocedural complications. Plain CT imaging after stenting revealed leakage of contrast agent, which disappeared on the second day, resulting in no clinical symptoms or neurological sequelae. Follow-up angiography studies were performed in all patients for 6-12 months (mean, 8.8). Slight asymptomatic in-stent stenosis was observed in 2 patients (16.7%), and no neurological deficits were observed in the other patients. All preoperative ischaemic symptoms completely disappeared at follow-up. CONCLUSION: Stent angioplasty is a safe and effective treatment for occlusion and stenosis of intracranial arteries in moyamoya disease.


Subject(s)
Endovascular Procedures , Moyamoya Disease , Stents , Humans , Moyamoya Disease/surgery , Female , Male , Adult , Treatment Outcome , Middle Aged , Angioplasty , Young Adult , Adolescent
8.
Am Heart J Plus ; 43: 100405, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38831788

ABSTRACT

Background: Coronary in-stent restenosis (ISR) is a major clinical challenge of contemporary percutaneous revascularization and portends adverse cardiovascular outcomes. Objectives: We aimed to evaluate gender, race, and ethnicity related outcomes in acute coronary syndromes (ACS) with ISR. Methods: Primary hospitalizations for ACS and ISR in the National Inpatient Sample database from 2016 to 2019 were included. Patients were stratified by gender, race, and ethnicity. The primary end points were all cause in-hospital mortality and coronary revascularization defined as composite of percutaneous coronary intervention (PCI), balloon angioplasty and/or coronary artery bypass grafting (CABG). Results: During the study period, a nationally weighted total of 97,680 patients with ACS and ISR were included. There was substantial variation in comorbidities, with greatest burden among Black and Hispanic women. All-cause in-hospital mortality was 2.4 % in the study cohort, but significantly higher in women (2.1 % vs. 2.1 %; aOR: 1.282, 95 % CI: 1.174-1.4; p < 0.001) and revascularization rates were significantly lower in women (77 % vs 80.2 %; aOR: 0.891, 95 % CI: 0.862-0.921; p < 0.001). Compared to White men, all women except Hispanic women, had significantly higher likelihood of in-hospital mortality, while White women, Black men and women, and Hispanic men had lower odds of revascularization. Conclusions: There are significant gender, racial, and ethnic related differences in revascularization practices and clinical outcomes in patients with ACS and ISR with an adverse impact on women, racial and ethnic minorities in the U.S.

9.
J Invasive Cardiol ; 2024 06 06.
Article in English | MEDLINE | ID: mdl-38848130

ABSTRACT

BACKGROUND: Lesion preparation with a cutting (CB) or scoring balloon (SB) is often used in patients with in-stent restenosis (ISR). However, there are no comparative studies. METHODS: We analyzed 81 patients (CB group: n = 38; SB group: n = 43) who had a calcified ISR from November 2019 to September 2021. The primary endpoint was strategy success (less than 20% residual stenosis); the secondary endpoints were major adverse cardiovascular events during the 1-year follow-up. Quantitative coronary angiography was performed to evaluate the strategy success. RESULTS: The patients in the CB group were more likely to have a severe calcified ISR (P = .001) and multiple stent layers (P = .001). A total of 64 patients (79.0%) reached the primary endpoint. Residual stenosis greater than 20% was more common in the CB group (39.5% vs 4.7%; P = .001). In the multivariate analysis, an effect of the intervention group on the achievement of the primary endpoint could be excluded (estimate 1.06; standard error 1.07; P = .322). The time interval of stent implantation prior to CB/SB (P = .007) and severe calcified ISR (P = .009) had a negative impact on reaching the primary endpoint. During the follow-up, there were no differences in rates of cardiac death (CB 2.5% vs. SB 1.2%; P = .598), acute myocardial infarction (CB 0% vs. SB 4.9%; P = .119), and target lesion failure (CB 3.7% vs SB 12.3%; P = .074). CONCLUSIONS: In our cohort, multivariate analysis showed that lesion preparation with CB or SB must be considered equivalent in terms of angiographic results. Factors like severe calcified ISR and the time interval of prior stent implantation negatively influenced the angiographic outcome.

10.
Curr Med Sci ; 44(3): 561-567, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38809380

ABSTRACT

OBJECTIVE: The study sought to investigate the clinical predictive value of quantitative flow ratio (QFR) for the long-term target vessel failure (TVF) outcome in patients with in-stent restenosis (ISR) by using drug-coated balloon (DCB) treatment after a long-term follow-up. METHODS: This was a retrospective study. A total of 186 patients who underwent DCB angioplasty for ISR in two hospitals from March 2014 to September 2019 were enrolled. The QFR of the entire target vessel was measured offline. The primary endpoint was TVF, including target vessel-cardiac death (TV-CD), target vessel-myocardial infarction (TV-MI), and clinically driven-target vessel revascularization (CD-TVR). RESULTS: The follow-up time was 3.09±1.53 years, and 50 patients had TVF. The QFR immediately after percutaneous coronary intervention (PCI) was significantly lower in the TVF group than in the no-TVF group. Multivariable Cox regression analysis indicated that the QFR immediately after PCI was an excellent predictor for TVF after the long-term follow-up [hazard ratio (HR): 5.15×10-5 (6.13×10-8-0.043); P<0.01]. Receiver-operating characteristic (ROC) curve analysis demonstrated that the optimal cut-off value of the QFR immediately after PCI for predicting the long-term TVF was 0.925 (area under the curve: 0.886, 95% confidence interval: 0.834-0.938; sensitivity: 83.40%, specificity: 88.00; P<0.01). In addition, QFR≤0.925 post-PCI was strongly correlated with the TVF, including TV-MI and CD-TVR (P<0.01). CONCLUSION: The QFR immediately after PCI showed a high predictive value of TVF after a long-term follow-up in ISR patients who underwent DCB angioplasty. A lower QFR immediately after PCI was associated with a worse TVF outcome.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Restenosis , Humans , Male , Female , Middle Aged , Coronary Restenosis/etiology , Coronary Restenosis/diagnostic imaging , Retrospective Studies , Aged , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon, Coronary/adverse effects , Drug-Eluting Stents , Follow-Up Studies , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Coronary Vessels/surgery
11.
J Am Coll Cardiol ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38752901

ABSTRACT

BACKGROUND: The impact of glycemic control in the risk of stent failure in subjects with type 2 diabetes (T2D) is currently unknown. OBJECTIVES: This study sought to study whether poor glycemic control is associated with a higher risk of stent failure in subjects with T2D. METHODS: This observational study included all patients in Sweden with T2D who underwent implantation of second-generation drug-eluting stents (DES) during 2010 to 2020. The exposure variable was the updated mean of glycated hemoglobin (HbA1c). Individuals were stratified by glycemic control, with HbA1c 6.1% to 7.0% (43-53 mmol/mol) as the reference group. The primary endpoint was the occurrence of stent failure (in-stent restenosis and stent thrombosis). The main result was analyzed in a complete cases model. Sensitivity analyses were performed for missing data and a model with death as a competing risk. RESULTS: The study population consisted of 52,457 individuals (70,453 DES). The number of complete cases was 24,411 (29,029 DES). The median follow-up was 6.4 years. The fully adjusted HR was 1.10 (95% CI: 0.80-1.52) for HbA1c of ≤5.5% (≤37 mmol/mol), 1.02 (95% CI: 0.85-1.23) for HbA1c of 5.6% to 6.0% (38-42 mmol/mol), 1.25 (95% CI: 1.11-1.41) for HbA1c of 7.1% to 8.0% (54-64 mmol/mol), 1.30 (95% CI: 1.13-1.51) for HbA1c of 8.1% to 9.0% (65-75 mmol/mol), 1.46 (95% CI: 1.21-1.76) for HbA1c of 9.1% to 10.0% (76-86 mmol/mol), and 1.33 (95% CI: 1.06-1.66) for HbA1c of ≥10.1% (≥87 mmol/mol). Sensitivity analyses did not change the main result. CONCLUSIONS: We found a significant association between poor glycemic control and a higher risk of stent failure driven by in-stent restenosis.

12.
Eur J Case Rep Intern Med ; 11(5): 004412, 2024.
Article in English | MEDLINE | ID: mdl-38715879

ABSTRACT

Intracoronary in-stent restenosis (ISR) is a phenomenon that generally occurs between 3 and 6 months after stent placement. With the introduction of drug-eluting stents (DES), the incidence of ISR has decreased but not disappeared. We report a case of reiterant in-stent restenosis of an 81-year-old female patient who underwent multiple percutaneous coronary intervention and two coronary artery bypass surgeries. ISR is possibly associated with extra-stent, stent-related and intra-stent factors. Here, we excluded the first two and focused on the intra-stent factors that seem more likely in our case. A challenging diagnostic workup led us to the hypothesis of a coronary vasculitis potentially triggered by some component of the stent in a predisposed patient carrier of non-disease-specific ANA, with an exaggerated immune response. No recurrence of ISR occurred after the introduction of steroids. Biological and intra-stent causes of ISR should be taken into careful consideration to aim for the early detection of the underlying mechanism of restenosis and to embrace the best therapeutic strategy. LEARNING POINTS: Intra-stent restenosis is possibly associated with extra-stent, stent-related and intra-stent factors.Coronary vasculitis is potentially triggered by some component of the stent in a predisposed patient.Immunosuppressive treatment should be taken into consideration in case of recurrent intra-stent restenosis.

13.
Sisli Etfal Hastan Tip Bul ; 58(1): 75-81, 2024.
Article in English | MEDLINE | ID: mdl-38808058

ABSTRACT

Objectives: Although the association of Atherogenic index of plasma (AIP) with coronary artery disease (CAD) and atherosclerosis is known, the relationship between AIP and in-stent restenosis (ISR) remains unclear. We aimed to investigate the relationship between AIP and ISR in patients with stable angina pectoris (SAP) treated with drug-eluting stent (DES). Methods: Patients with a history of DES implantation following stable angina were evaluated between January 2015 and November 2019 in this observational and retrospective study. 608 eligible patients were dichotomized into ISR+ (n=241) and ISR- (n=367). ISR was defined as the presence of 50% or greater stenosis. AIP was defined as log [TG/HDL-C]. Results: AIP levels were significantly higher in patients who developed ISR compared with those who did not (0.33 [0.15-0.52] vs 0.06 [-0.08-0.21] respectively, p<0.001). The AUC value of AIP levels for predicting ISR was 0.746 (p<0.001). Multivariate logistic regression analysis revealed that AIP, diabetes mellitus, higher LDL-C levels and lower LVEF values were independently associated with ISR. Conclusion: Multivariate analysis revealed that AIP was strongly independently associated with ISR. Using this novel inexpensive and easily calculable index may provide early recognition of ISR in patients with SAP who were treated with DES.

14.
BMC Cardiovasc Disord ; 24(1): 234, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702615

ABSTRACT

BACKGROUND: Insulin resistance (IR) can lead to cellular metabolic disorders, activation of oxidative stress, and endothelial dysfunction, contributing to in-stent restenosis (ISR). The triglyceride-glucose index (TyG index), a new indicator reflecting IR, is extensively researched in the cardiovascular field. This study, through a meta-analysis, aimed to utilize a larger combined sample size and thereby enhance the overall test efficacy to explore the TyG index-ISR relationship. METHODS: A thorough search was conducted in the PubMed, EMBASE, Web of Science, and Cochrane Library databases to find original papers and their references published between 1990 and January 2024. This search included both prospective and retrospective studies detailing the correlation between the TyG index and ISR in individuals with coronary heart disease (CHD). OUTCOMES: The five included articles comprised 3,912 participants, and the odds ratio (OR) extracted from each study was combined using the Inverse Variance method. Results showed that, in the context of CHD patients, each incremental unit in the TyG index, when treated as a continuous variable, corresponded to a 42% elevation in ISR risk (95% CI 1.26-1.59, I²=13%, p < 0.005). When analyzing the TyG index categorically, the results revealed a higher ISR risk in the highest TyG index group compared to the lowest group (OR: 1.69, 95% CI 1.32-2.17, I²=0). Additionally, in patients with chronic coronary syndrome (CCS), each unit increase in the TyG index, the risk of ISR in patients increased by 37% (95% CI 1.19-1.57, I²=0%, p < 0.005). This correlation was also observable in acute coronary syndrome (ACS) patients (OR:1.48, 95% CI 1.19-1.85, I²=0, p < 0.005). CONCLUSIONS: The TyG index, an economical and precise surrogate for IR, is significantly linked with ISR. Furthermore, this correlation is unaffected by the type of coronary heart disease.


Subject(s)
Biomarkers , Blood Glucose , Coronary Artery Disease , Coronary Restenosis , Insulin Resistance , Percutaneous Coronary Intervention , Stents , Triglycerides , Humans , Biomarkers/blood , Blood Glucose/metabolism , Coronary Artery Disease/blood , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnosis , Coronary Restenosis/blood , Coronary Restenosis/etiology , Coronary Restenosis/diagnosis , Coronary Restenosis/diagnostic imaging , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Predictive Value of Tests , Risk Assessment , Risk Factors , Treatment Outcome , Triglycerides/blood
15.
Vasc Endovascular Surg ; : 15385744241253170, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38739243

ABSTRACT

BACKGROUND: Drug-eluting devices improved outcomes of endovascular therapy (EVT) for femoropopliteal lesions, but mainly for de novo lesions. Endovascular therapy for in-stent restenosis/occlusion (ISR/O) is challenging, and large trials and long-term data are not well reported. MATERIALS AND METHODS: This study is a physician initiated, multicenter, and retrospective design. From 7 Japanese institutes, 3635 femoropopliteal cases were enrolled in the study. Among these, 346 cases of first ISR/O were studied. We defined drug-coated-balloon, drug-eluting stent, and covered stent as New devices. Balloon angioplasty and bare nitinol stent were included in the control group. RESULTS: The propensity score matching extracted 112 pairs. At 12 months, the primary patency rate was 80.3% in the new device group and 52.7% in the control group, and there was a significant intergroup difference (P = .004). However, at 36 months, the rate was 43.3% vs 39.2%, with no significant difference (P = .090). No baseline characteristics had any significant interaction effect (all P > .05). CONCLUSIONS: The New devices were more effective than the control group for ISR/O at 1 year, but caught up at 3 years.

16.
Circ Cardiovasc Interv ; 17(5): e013302, 2024 May.
Article in English | MEDLINE | ID: mdl-38771909

ABSTRACT

Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant. Presently, in-stent restenosis is the condition with the most robust evidence supporting the use of DCBs. DCBs provide improved long-term vessel patency compared with conventional balloon angioplasty and may be comparable to drug-eluting stents without the need for an additional stent layer, supporting their use as a first-line therapy for in-stent restenosis. Beyond the treatment of in-stent restenosis, DCBs provide an additional tool for de novo lesions for a strategy that avoids a permanent metal scaffold, which may be especially useful for the management of technically challenging anatomies such as small vessels and bifurcations. DCBs might also be advantageous for patients with high bleeding risk due to the decreased necessity for extended antiplatelet therapy, and in patients with diabetes and patients with diffuse disease to minimize long-stented segments. Further studies are crucial to confirm these broader applications for DCBs and to further validate safety and efficacy.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Cardiovascular Agents , Coated Materials, Biocompatible , Coronary Artery Disease , Coronary Restenosis , Humans , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Treatment Outcome , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Equipment Design , Risk Factors , Vascular Patency , Drug-Eluting Stents
17.
Lasers Surg Med ; 56(5): 474-484, 2024 07.
Article in English | MEDLINE | ID: mdl-38738401

ABSTRACT

OBJECTIVES: The aim of this study is to investigate the safety and efficacy of excimer laser coronary angioplasty (ELCA) combined with drug-coated balloons (DCBs) in the treatment of in-stent restenosis (ISR), and to explore whether the contrast injection technique would improve the neointimal tissue ablation of ELCA. METHODS: We studied patients diagnosed with ISR between January 2019 and October 2022 at two medical centers. These patients underwent DCB angioplasty guided by optical coherence tomography (OCT). Based on whether ELCA was performed before DCB treatment, patients were categorized into two groups: the ELCA + DCB group and the DCB group. All patients underwent clinical follow-up 1 year after the procedure. The primary endpoint was the 1-year rate of target lesion revascularization (TLR), which was defined as any repeat percutaneous intervention or bypass surgery on the target vessel conducted to address restenosis or other complications related to the target lesion. The secondary endpoints including immediate luminal gain (ΔMLA, defined as the difference in minimum lumen area before and after the intervention). RESULTS: A total of 85 lesions in 75 patients were included. The mean age of the study population was 64.2 ± 12.0 years, with 81.3% male. Baseline clinical characteristics were well-balanced, and procedural success was 100% in both groups. The ELCA + DCB group (n = 24) exhibited a greater ΔMLA compared to the DCB group (n = 61) (3.57 ± 0.79 mm² vs. 2.50 ± 1.06 mm², [95% confidence interval, CI: 0.57-1.69], p < 0.001), The reduction in 1-year TLR was more frequently observed in patients from the ELCA + DCB group compared to the DCB group (hazard ratio 0.33 [95% CI: 0.11-0.99]; log-rank p = 0.048). The exploratory analysis showed that ELCA with contrast infusion is associated with greater acute lumen gain compared to ELCA with saline infusion (p < 0.001). CONCLUSIONS: The combination of ELCA and DCB is a safe and effective treatment strategy for in-stent stenosis. Additionally, compared with saline injection, ELCA with contrast injection is associated with greater acute lumen gain. However, the optimal contrast agent concentration and long-term outcome of the contrast injection technique need confirmation through larger sample sizes and prospective studies.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Restenosis , Lasers, Excimer , Humans , Male , Middle Aged , Female , Coronary Restenosis/therapy , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Aged , Lasers, Excimer/therapeutic use , Angioplasty, Balloon, Coronary/instrumentation , Treatment Outcome , Retrospective Studies , Drug-Eluting Stents , Tomography, Optical Coherence , Combined Modality Therapy , Angioplasty, Balloon, Laser-Assisted
18.
J Vasc Surg Cases Innov Tech ; 10(4): 101507, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38799648

ABSTRACT

Intravascular lithotripsy (IVL) has been used for the treatment of native highly calcified arterial lesions. No data are available in the literature about its use in the treatment of noncoronary in-stent restenosis (ISR). We report the case of kissing IVL in highly calcified iliac ISR related to underexpansion of stents previously deployed in the common iliac arteries. The procedures were performed with a combined percutaneous right femoral and surgical left axillary access. This case demonstrates the safety and effectiveness of IVL even for the treatment of iliac ISR when other "standard" techniques cannot be used to obtain a satisfactory outcome. This technique needs to be evaluated further with multicenter experiences and adequate population sizes.

19.
Front Neurol ; 15: 1304524, 2024.
Article in English | MEDLINE | ID: mdl-38585365

ABSTRACT

Background: Endovascular treatment of severe intracranial atherosclerotic stenosis (ICAS) using coronary drug-eluting stents (DESs) significantly reduces the risk of in-stent restenosis (ISR) and stroke recurrence. However, there are few reports regarding the treatment of ICAS with intracranial dedicated DES. Herein, we present our experience with the feasibility, safety, and medium-term follow-up outcomes of a novel intracranial DES, named NOVA stent, in patients with symptomatic severe ICAS (≥70%). Methods: From December 2021 to May 2022, patients with symptomatic severe ICAS who underwent implantation of the NOVA stent in our institution were retrospectively analyzed for procedural results, perioperative complications, imaging and clinical follow-up outcomes. Results: Twenty-four patients, 16 (66.7%) with anterior circulation lesions and 8 (33.3%) with posterior circulation lesions, were enrolled. All patients with intracranial ICA (n = 6), middle cerebral artery (n = 10), basilar artery (n = 3), intracranial vertebral artery (n = 3), and the vertebrobasilar junction (n = 2) stenosis were treated successfully using NOVA stents. The severity of stenosis ranged from 75 to 96% (mean 85.9%) before treatment and this was reduced to 0 to 20% (mean 8.6%) immediately after stent placement. Symptomatic distal embolism occurred in one case; however, there were no other perioperative complications. The mean follow-up duration was 12.2 ± 1.06 months. No symptomatic ischemic events occurred during follow-up. Follow-up cerebral angiography was performed in 22 of 24 patients (91.7%), and significant ISR occurred in one patient (4.2%). Conclusion: Our results demonstrate that implantation of the novel intracranial DES NOVA in severe ICAS is feasible, safe, and effective in selected cases, reducing the incidence of ISR, and showing excellent midterm clinical outcomes, providing a promising option for ICAS treatment.

SELECTION OF CITATIONS
SEARCH DETAIL
...