Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Publication year range
1.
Belo Horizonte; s.n; 2017. 69 p. ilus.
Thesis in English, Portuguese | BBO - Dentistry | ID: biblio-907040

ABSTRACT

A capacidade e eficiência de corte dos instrumentos endodônticos de Níquel-Titânio (NiTi) são complexas e relacionadas a diversos fatores, como a técnica de instrumentação utilizada e as características geométricas e dimensionais dos instrumentos. Neste trabalho, o objetivo foi avaliar a ação de corte através do torque exercido durante o preparo de canais radiculares por instrumentos BioRaCe, (FKG Dentaire Swiss Endo - La Chaux-de-Fonds, Suíça) BR0 25/.08, BR1 15/.05, BR2 25/.04, BR3 25/.06, BR4 35/.04 e BT-RaCe (FKG Dentaire Swiss Endo - La Chaux-de-Fonds, Suíça) BTR1 10/.06, BTR2 35/.00 e BTR3 35/.04. Inicialmente, os instrumentos foram caracterizados com relação ao diâmetro a cada milímetro da parte ativa e comprimento de pitch. Os instrumentos foram fotografados e a análise das imagens foi realizada com o software ImageJ. Os ensaios de eficiência de corte foram realizados em 20 pré-molares com duas raízes distintas com curvatura gradual e discreta entre 10º e 25º (classe I) e comprimento total dos canais entre 19 e 23mm, selecionados do banco de dentes da FOUFMG. Após radiografia digital inicial, foi realizado acesso coronário e odontometria com limas manuais de aço inoxidável K#10 e K#15. Dez dentes foram instrumentados seguindo a técnica preconizada pelo fabricante para cada sistema. Um multímetro, acoplado ao motor endodôntico, registrou o torque requerido por cada instrumento durante o preparo dos canais. A ação de corte e o comportamento dos instrumentos durante o preparo dos canais foram avaliados através das curvas torque versus tempo. Os resultados da caracterização geométrica e dimensional dos instrumentos indicaram que a medida dos mesmos é compatível com os valores preconizados pelo fabricante. Na análise do comprimento de pitch, as limas mostraram arestas de corte alternadas e progressivas, exceção apenas para a BTR2, cujo pitch foi constante. Quanto ao tempo de utilização dos instrumentos, os resultados indicaram que os sistemas BioRaCe e BT-RaCe demonstraram diferenças nos tempos dos ensaios de eficiência de corte, devido, principalmente, à diferença do número de instrumentos utilizados em cada sequência. Por fim, não houve diferença estatística entre a ação de corte dos instrumentos que demandaram maior torque médio durante a instrumentação, BR3 para o sistema BioRaCe e BTR3 para o sistema BT-RaCe. A diminuição do número de instrumentos para o preparo de canais mostrou, nas limitações deste estudo e nas sequencias avaliadas, um torque máximo seguro para o uso clínico, bem como a diminuição do tempo clínico


The cutting abiblity and efficiency of Niquel Titanium (NiTi) endodontic instruments are complex and related to many different factors such as the instrumentation technique and the gemetric and dimensional characteristics of the instruments. The goal of the present work was to assess the cutting action through the torque exerted during the preparation of root canals with BioRaCe instrumets, (FKG Dentaire Swiss Endo-La Chaux-de-Fonds, Suiça)...


Subject(s)
Humans , Male , Female , Dental Instruments/statistics & numerical data , Root Canal Preparation/instrumentation , Root Canal Therapy/instrumentation , Image Processing, Computer-Assisted/statistics & numerical data , Torque
2.
Belo Horizonte; s.n; 2016. 37 p. ilus.
Thesis in English, Portuguese | BBO - Dentistry | ID: biblio-946494

ABSTRACT

Os instrumentos rotatórios fabricados em Níquel-Titânio possuem características geométricas e dimensionais que influenciam sua eficiência de corte. Torque e força apical exercidos durante o preparo de canais radiculares são parâmetros que definem esta propriedade mecânica. Neste estudo avaliou-se o torque e a força apical exercidos por instrumentos ProTaper Universal (PTU) S2 e F1 e ProTaper NEXT (PTN) X1 e X2, que apresentam diâmetros semelhantes e geometrias diferentes. Os ensaios foram realizados em dispositivo de bancada, onde 10 instrumentos de cada tipo foram testados em blocos de acrílico préfabricados, contendo um canal artificial previamente explorado com limas rotatórias PathFile #13 e #16. Acionados por um motor endodôntico com velocidade de 300 rotações por minuto (rpm) e torque de 4,0 Newton por centímetro (Ncm), os instrumentos foram inseridos no canal a uma velocidade constante de 0,09 mm/seg. Enquanto uma célula de carga registrou a força axial exercida, um multímetro acoplado ao motor endodôntico registrou o torque requerido pelo instrumento durante seu deslocamento ao longo do canal. Os ensaios foram realizados utilizando um bloco novo para cada sistema, na sequência de S2 e F1 para PTU, e X1 e X2 para PTN. Os resultados mostraram que os instrumentos do sistema PTU apresentaram menores valores de força apical e torque, quando comparados com PTN


The NiTi instruments have geometrical and dimensional characteristics that could play an important hole in the cutting efficiency. Torque and apical force exerted during the root canal preparation are parameters that define this mechanical property. This study evaluated the apical force and torque required by the instruments ProTaper Universal (PTU) S2 and F1, and ProTaper NEXT (PTN) X1 and X2, with similar diameters and different geometries, to penetrate standardized acrylic blocks containing an artificial canal previously explored with rotary instruments Pathfile #13 and #16. The parameters were determined using a bench-testing machine, where the instruments were set to move against the artificial canal in a constant speed of 0.09 mm/sec. The X-Smart Plus motor, with a rotational speed of 300 rpm and torque limitation of 4N.cm, was employed to drive the instruments and the load cell of the machine recorded the apical force exerted, while a digital multimeter attached to the endodontic motor recorded the torque required during the work of the instrument along the canal. Ten instruments of each type were tested using a new acrylic block for each system, in a sequence of S2 and F1 for PTU, and X1 and X2 for PTN. The results showed that the instruments of the PTU system displayed lower torque and apical force during the test, when compared to PTN instruments


Subject(s)
Dental Instruments/classification , Root Canal Preparation/instrumentation , Root Canal Therapy/instrumentation , Benchmarking/statistics & numerical data , Torque
3.
Belo Horizonte; s.n; 2015. 118 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: lil-790344

ABSTRACT

As propriedades mecânicas, especialmente a resistência dos instrumentos endodônticos de NiTi são influênciadas pelas suas características geométricas, físicas e químicas, somadas ainda à influência da anatomia dos canais radiculares. A exploração e negociação do canal radicular seguido de dilatação prévia ao processo de formatação (Glide Path) reduz consideravelmente as chances de fratura dos instrumentos. Essa manobra elimina as interferências em toda a extensão do canal, possibilitando aos instrumentos seguintes agirem livremente na formação e limpeza minimizando assim, a sobrecarga sobre o mesmo. O objetivo desse trabalho foi avaliar a resitência torcional após uso clínico múltiplo dos instrumentos de Niti PathFile e Scout RaCe e a influência de três diferentes sequências de glide path (K-File, PathFile e Scout RaCe) no comportamento em torção dos instrumentos de formatação MtWo...


The mechanical properties, mainly the resistance of endodontic instruments are affected by factors such as diameter, design, chemical composition, physical properties and canal anatomy. Instrument failure can be controlled by creating a manual or mechanical glide path. The aim of this study was to evaluate the torsional resistance of PathFile and Scout RaCe NiTi rotary instruments with the purpose of "glide path” after multiple clinical use and the influence of three different preflaring (K-File, PathFile and Scout RaCe) on the torsional resistance of shaping Mtwo files after multiple clinical use. The mechanical behavior was evaluated by torsion tests, in accordance with specification ISO 3630-1. All instruments showed geometric features within the tolerance limits and no significant difference concerned about the torsional resistance. Despite of one subtle increase in torsional resistance is noted, it is suggested as an effect of simultaneous sterilization methods or by the work hardening of the NiTi alloy. The present study highlights the importance of preparing the glide path before introducing the shaping files and concludes if sterilization does not render rotary NiTi endodontic instruments stronger, it does not result in deleterious effects that could reducetheir mechanical resistance.


Subject(s)
Dental Instruments , Materials Science/analysis , Stainless Steel , Root Canal Therapy/instrumentation , Infection Control, Dental , Nickel/therapeutic use , Torque , Titanium/therapeutic use
4.
ROBRAC ; 19(48)abr. 2010. tab
Article in Portuguese | LILACS | ID: lil-558310

ABSTRACT

No presente trabalho avaliou-se e comparou-se a carga necessária para induzir uma determinada deformação elástica de instrumentos endodônticos de NiTi mecanizados de mesmo número e de quatro marcas comerciais. Nos ensaios mecânicos de flexão em cantilever os instrumentos foram fixados em uma das extremidades e a carga aplicada na extremidade oposta. Os resultados obtidos demonstraram que em termos de flexibilidade: TF > BioRace > K3 > ProTaper.


In the present study evaluated and compared the load required to induce a certain elastic deformation of NiTi endodontic instruments mechanized same number and four trademarks. In the mechanical cantilever bending the instruments were set at one end and the load applied at the opposite end. The results showed that in terms of flexibility: TF> BioRace> K3> ProTaper.

5.
Rev. bras. odontol ; 66(1): 93-96, jan.-jun. 2009. tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-575391

ABSTRACT

O objetivo deste trabalho foi avaliar a influência da liga metálica na flexibilidade de instrumentos endodônticos. Foram utilizados instrumentos endodônticos de aço inoxidável e de NiTi de 25 mm de comprimento útil, conicidadede 0,02 mm/mm e de números 40 e 45. A flexibilidade dos instrumentos foi determinada por meio de um ensaio de flexão em cantilever. Com base nos resultados experimentais obtidos, pode-se concluir que entre os instrumentos endodônticos tipo K de mesmo número, os de NiTi são mais flexíveis e menos rígidos do que os de aço inoxidável.


Subject(s)
Dental Instruments/standards , Nickel , Pliability , Root Canal Preparation/instrumentation , Stainless Steel , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL