Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.165
Filter
1.
J Card Fail ; 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39097162

ABSTRACT

Markers of social health, including kinlessness, social isolation, and loneliness, have important implications for quality of life and health for older adults. As the population ages, there is a growing cohort of kinless older adults without living partners or children, particularly among disadvantaged groups. Kinlessness has been associated with worse mental and physical health, significant unmet care needs, increased risk of dementia, higher rates of long-term placement, and higher mortality than for patients with kin. Though other markers of social health have been studied in patients with heart failure, little is known about kinlessness in this patient population. This review outlines the data on kinlessness, its impact on patient outcomes, and proposes novel interventions to mitigate its effects.

2.
Front Cardiovasc Med ; 11: 1417005, 2024.
Article in English | MEDLINE | ID: mdl-39108666

ABSTRACT

Objective: To characterize the gas production phenomenon in the animal model of left ventricular assist device (LVAD), and study its mechanism. Methods: An in vitro bubble precipitation experiment was conducted, and the blood samples of Parma spp. animals were divided into ordinary group and oxygen-enriched group according to whether they were oxygenated or not at the time of blood collection, and a static control group was set up respectively. Blood gases were drawn and analyzed before and after the experiment. Activate the pump, and the number of air bubbles in the loop was measured by ultrasound at different rotational speeds; CFD was applied to simulate the flow field in the blood pump, and pressure, fluid velocity vector and shear force diagrams were plotted, and a thrombus model was constructed and the flow field was simulated and plotted as a cloud diagram. Results: There was a statistical difference in the number of bubbles in the inflow and outflow tubes of the blood pump (P values of 0.04 and 0.023, respectively), and the number of bubbles in the outflow tubes of both groups was significantly higher than the number of bubbles in the inflow tubes. The number of bubbles in the tubes of both the oxygen-enriched and normal groups was significantly higher than that in the inflow group. In both the normal and oxygen-enriched groups, more gas was produced at higher speeds than at lower speeds. Blood gas analysis showed that the reduced gas composition in the blood was mainly oxygen. Flow field simulation results: the high rotation speed group had lower central pressure and greater scalar shear. The thrombus simulation group was more prone to turbulence, sudden pressure changes, and greater shear than the normal group. Conclusion: Blood gas production is associated with higher partial pressures of blood oxygen, higher rotation speed, and intrapump thrombosis, and the mechanism of pump gas production is degassing of dissolved gases rather than cavitation of water, and the gas released is most likely to have oxygen. The degassing phenomenon is an warning factor for pump thrombosis.

4.
Int J Cardiol ; 413: 132340, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38992809

ABSTRACT

BACKGROUND: The current incidence and outcomes of structural transcatheter procedures in heart transplant (HTx) recipients and left-ventricular assist devices (LVAD) carriers is unknown. AIMS: To provide insights on structural transcatheter procedures performed across HTx and LVAD patients in Spain. METHODS: Multicenter, ambispective, observational nationwide registry. RESULTS: Until May/2023, 36 percutaneous structural interventions were performed (78% for HTx and 22% for LVAD) widely varying among centers (0%-1.4% and 0%-25%, respectively). Percutaneous mitral transcatheter edge-to-edge (TEER) was the most common (n = 12, 33.3%), followed by trancatheter aortic valve replacement (n = 11, 30.5%), and tricuspid procedures (n = 9, 25%). Mitral TEER resulted in mild residual mitral regurgitation in all but one case, mean gradient was <5 mmHg in 75% of them at 1-year, with no mortality and 8.3% re-admission rate. Tricuspid TEER resulted in 100% none/mild residual regurgitation with a 1-year mortality and readmission rates of 22% and 28.5%, respectively. Finally, trancatheter aortic valve replacement procedures (n = 8 in LVADs due to aortic regurgitation and n = 3 in HTx), were successful in all cases with one prosthesis degeneration leading to severe aortic regurgitation at 1-year, 18.2% mortality rate and no re-admissions. Globally, major bleeding rates were 7.9% and 12.5%, thromboembolic events 3.7% and 12.5%, readmissions 37% and 25%, and mortality 22% and 25%, in HTx and LVADs respectively. No death was related to the implanted transcatheter device. CONCLUSIONS: Most centers with HTx/LVAD programs perform structural percutaneous procedures but with very inconsistent incidence. They were associated with good safety and efficacy, but larger studies are required to provide formal recommendations.

5.
JACC Basic Transl Sci ; 9(5): 674-686, 2024 May.
Article in English | MEDLINE | ID: mdl-38984052

ABSTRACT

The adult mammalian heart harbors minute levels of cycling cardiomyocytes (CMs). Large numbers of images are needed to accurately quantify cycling events using microscopy-based methods. CardioCount is a new deep learning-based pipeline to rigorously score nuclei in microscopic images. When applied to a repository of 368,434 human microscopic images, we found evidence of coupled growth between CMs and cardiac endothelial cells in the adult human heart. Additionally, we found that vascular rarefaction and CM hypertrophy are interrelated in end-stage heart failure. CardioCount is available for use via GitHub and via Google Colab for users with minimal machine learning experience.

6.
Psychiatr Pol ; 58(2): 277-287, 2024 Apr 30.
Article in English, Polish | MEDLINE | ID: mdl-39003511

ABSTRACT

Treatment of patients with advanced heart failure (HF) with the use of left ventricular assist devices (LVADs) improves the quality of life and the length of survival. Despite the undeniable benefits associated with improved physical performance, as a result of the decrease of the underlying disease symptoms, it carries the risk of complications in the area of the patient's somatic and psychological status. Long-term circulatory failure can contribute to a weakening of the adaptative mechanism and consequently lead to a variety of emotional disruptions. Patients must face the fear of imminent physical, family, and social changes that LVAD requires. They may experience sleep disorders, mood disorders, anxiety disorders, and in the early postoperative period also disorders of consciousness with a pattern of delirium. For this reason, it is advisable to provide multidisciplinary medical care for the patient at all stages of treatment, including regular monitoring of general health and mental health. This article presents risk factors for psychiatric disorders in patients with LVADs and ways of pharmacological and non-pharmacological management when these factors are identified and disorders are diagnosed.


Subject(s)
Heart Failure , Heart-Assist Devices , Mental Disorders , Humans , Heart-Assist Devices/psychology , Heart Failure/psychology , Heart Failure/therapy , Mental Disorders/therapy , Mental Disorders/psychology , Quality of Life/psychology , Adaptation, Psychological , Postoperative Period
7.
Am J Cardiol ; 2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38972536

ABSTRACT

The United Network for Organ Sharing (UNOS) adopted new criteria for the heart allocation score on October 18, 2018 to reflect the changing trends of candidates' mortality while awaiting transplant. We examined the impact of these policy changes on rates of left ventricular assist device (LVAD) implantation and outcomes after transplant from a relatively newer UNOS database. The UNOS registry was used to identify first-time adult heart recipients with LVAD at listing or transplant who underwent transplantation between January 1, 2016 and March 10, 2020. Survival data were collected through March 30, 2023. Those listed before October 18, 2018 but transplanted after were excluded. Patients were divided into before or after change groups. Demographics and clinical parameters were compared. Survival was analyzed with Kaplan-Meier curves and log-rank tests. A p <0.05 was considered significant. We identified 4,387 heart recipients with LVAD in the before (n = 3,606) and after (n = 781) score change eras. The after group had a lower rate of LVAD implantation while listed than the before group (20.4% vs 34.9%, p <0.0001), and were more likely to be female (25.1% vs 20.2%, p = 0.002); in both groups, most recipients (62.8%) were white. There was significantly farther distance from the donor hospital to transplant center in the after group (264.4 NM vs 144.2 NM, p <0.0001) and decreased waitlist days (84.9 ± 105.1 vs 369.2 ± 459.5, p <0.0001). Recipients in the after group were more likely to use extracorporeal membrane oxygenation (3.7% vs 0.5%, p <0.0001) and intravenous inotropes (19.1% vs 7.5%, p <0.0001) and receive a Centers for Disease Control and Prevention increased risk donor organ (37.9% vs 30.5%, p <0.0001). Survival at 3 years was comparable between the 2 groups. The allocation score change in 2018 yielded considerable changes in mechanical circulatory support device implantation strategy and outcomes. The rate of LVAD implantation decreased with increased utilization of temporary mechanical circulatory support devices.

8.
Mol Imaging Biol ; 2024 Jul 31.
Article in English | MEDLINE | ID: mdl-39085535

ABSTRACT

PURPOSE: Left ventricular assisting device (LVAD) is a vital mechanical circulatory assist device for patients with end-stage heart disease, serving as either a bridge to transplantation or palliative destination therapy. Yet device infection represents a major lethal complication, warranting a multi-step, complex therapy approach including an urgent device exchange or heart transplantation. Still, timely diagnosis of site and extent of VAD-specific infection for a proper therapy planning poses challenges in regular clinical care. This single-center, retrospective study aimed to evaluate the impact of volumetric PET parameters with different thresholding compared to semiquantitative PET parameters for accurate diagnosis of VAD-specific infection. PROCEDURES: Seventeen patients (1 female, 16 males; mean age 57 ± 11 years) underwent [18F]FDG imaging for suspected VAD-specific infection between April 2013 and October 2023. Various metabolic and volumetric PET parameters with different thresholding were collected for specific LVAD components including driveline entry point, subcutaneous driveline, pump pocket, inner cannula and outflow tract. Microbiology and clinical follow-up were used as the final diagnosis standard. RESULTS: Nine of eleven patients with VAD-specific infection underwent urgent heart transplantation, and one had a surgical revision of LVAD. Two patients had non-VAD specific infections, and two had non-VAD related infections. Metabolic burden determination using a fixed absolute threshold provided the best outcome compared to relative thresholding or other metabolic SUV parameters. The total metabolic tumor volume (MTV) cutoff value was 9.3 cm3, and the corresponding sensitivity, specificity, accuracy, and AUC were 90.0%, 71.43%, 82.5%, and 0.814 (95% CI 0.555-0.958), respectively. The total lesion glycolysis (TLG) was 30.6, and the corresponding sensitivity, specificity, accuracy, and AUC were 90.0%, 71.4%, 82.5%, and 0.829 (95% CI 0.571-0.964), respectively. CONCLUSIONS: Volumetric PET parameters with fixed absolute thresholding appear to be a valuable auxiliary tool in the evaluation of [18F]FDG imaging to enhance the diagnostic accuracy of VAD-specific infection.

9.
J Clin Med ; 13(14)2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39064136

ABSTRACT

Background: Donor shortage limits the utilization of heart transplantation, making it available for only a fraction of the patients on the transplant waiting list. Therefore, continuous-flow left ventricular assist devices (CF-LVADs) have evolved as a standard of care for end-stage heart failure. It is imperative therefore to investigate long-term survival in this population. Methods: This study assesses the impact of demographics, infections, comorbidities, types of cardiomyopathies, arrhythmias, and end-organ dysfunction on the long-term survival of LVAD recipients. The TriNetX database comprises de-identified patient information across healthcare organizations. The log-rank test assessed post-implant survival effects, while Cox regression was used in the univariate analysis to obtain the Hazard Ratio (HR). All analyses were conducted using the Python programming language and the lifelines library. Results: This study identified CMV, hepatitis A exposure, atrial fibrillation, paroxysmal ventricular tachycardia, ischemic cardiomyopathy, renal dysfunction, diabetes, COPD, mitral valve disease, and essential hypertension as risk factors that impact long-term survival. Interestingly, hypokalemia seems to have a protective effect and gender does not affect survival significantly. Conclusions: This is the first report of a detailed long-term survival assessment of the LVAD population using a decoded database.

10.
Front Cardiovasc Med ; 11: 1379199, 2024.
Article in English | MEDLINE | ID: mdl-39015682

ABSTRACT

Aims: Impella 5.0 and 5.5 are promising low-invasive left ventricle (LV) temporary mechanical circulatory supports (tMCS) for cardiogenic shock due to LV mechanical unloading and are paired with powerful hemodynamic support. This study aimed to analyze data and destinies of patients supported with Impella 5.0/5.5 at a national referral center for cardiogenic shock and to assess the parameters associated with myocardial recovery and successful weaning. Methods: A single-center observational study was conducted on all patients treated with Impella 5.0 or 5.5 from March 2018 to July 2023. Results: A total of 59 patients underwent Impella 5.0/5.5 implantation due to profound cardiogenic shock, with acute myocardial infarction being the most frequent cause of shock (42 patients, 71%). The median duration of Impella support was 13 days (maximum duration of 52 days). Axillary cannulation was feasible in almost all patients, and 36% were mobilized during support. A total of 44 patients (75%) survived to the next therapy/recovery: 21 patients experienced recovery and 15 and 8 were bridged to long-term LVAD and heart transplantation, respectively. The global survival rate was 66%. The predictors of native heart recovery at multivariate analysis were the number of days on tMCS before upgrade to Impella 5.0/5.5 [hazard ratio (HR) 0.68 (0.51-9) p = 0.0068] and improvement of LVEF within the first 7-10 days of support [HR 4.72 (1.34-16.7), p = 0.016]. Conclusions: Transcatheter systems such as Impella 5.0/5.5 revolutionized the field of tMCS. Myocardial recovery is the primary clinical target. Its prognostication and promotion are key to ensure the most proficuous course for each patient from cardiogenic shock to long-term event-free survival.

11.
Int J Cardiol ; 413: 132396, 2024 Jul 28.
Article in English | MEDLINE | ID: mdl-39079586

ABSTRACT

INTRODUCTION: The pathophysiology of HCM presents unique challenges for the management of cardiogenic shock and the use of mechanical circulatory support devices (MCSD). However, outcomes investigations for MCSD and HT in HCM patients is limited to case reports. The present study investigated MCSD and HT outcomes in HCM patients in a large retrospective cohort. METHODS: The National Inpatient Sample (2016-2019) was used for the retrospective analysis of patients hospitalized for MCSD and HT using ICD-10 codes. Patients with implantation of more than one device category were excluded. These patients were divided into two cohorts, with and without HCM, and compared in terms of in-hospital mortality, trends in mortality rates, hospitalization costs and mean length of stay. RESULTS: Among 267,780 patients hospitalized for MCSD and HT, 1155 patients had underlying HCM. Underlying HCM was associated with increased odds of mortality in patients receiving left ventricular assist devices (LVAD) (OR 3.4, 95% CI 1.03-11.2, p = 0.04) and temporary MCSD (OR 2.5, CI 1.8-3.6, p < 0.001). HCM was not associated with increased mortality in patients hospitalized for HT (OR 0.67, CI 0.15-2.85, p = 0.6). Patients with HCM undergoing MCSD and HT had a longer mean length of stay (22.1 vs 13.2 days, p = 0.004), and higher mean hospitalization charges ($830,103 vs $460,383, p < 0.0001) as compared to non-HCM patients. CONCLUSION: Underlying HCM is associated with increased in-hospital mortality in patients undergoing LVAD and temporary MCSD placement. Further prospective studies are required to expand our understanding of prognosis among HCM patients undergoing MCSD and establish management guidelines.

12.
Article in English | MEDLINE | ID: mdl-39069161

ABSTRACT

The development of aortic insufficiency (AI) during HeartMate 3 durable left ventricular assist device support (dLVAD) can lead to ineffective pump output and recurrent heart failure symptoms. Progression of AI often comingles with the occurrence of other hemodynamic related events encountered during LVAD support, including right heart failure, arrhythmias, and cardiorenal syndrome. While data on AI burdens and clinical impact are still insufficient in patients on HeartMate 3 support, moderate or worse AI occurs in approximately 8% of patients by 1 year and studies suggest AI continues to progress over time and is associated with increased frequency of right heart failure. The first line intervention for AI management is prevention, undertaking surgical intervention on the insufficient valve at the time of dLVAD implant and avoiding excessive device flows and hypertension during long term support. Device speed augmentation may then be undertaken to try and overcome the insufficient lesion, but progression of AI should be anticipated over the long term. Surgical or transcatheter aortic valve interventions may be considered in dLVAD patients with significant persistent AI despite medical management, but neither intervention is without risk. It is imperative that future studies of dLVAD support capture AI in clinical endpoints using uniform assessment and grading of AI severity by individuals trained in AI assessment during dLVAD support.

13.
Article in English | MEDLINE | ID: mdl-39019352

ABSTRACT

While notable improvements in survival, the incidence of hemocompatibility-related adverse events, hospitalizations, and cost have been demonstrated with the only commercially available durable left ventricular assist device, a category of pump malfunctions characterized by outflow graft obstruction has been noted with broader use and clinical follow-up of recipients of this technology. Of particular concern is the accumulation of acellular biodebris between the outflow graft and bend relief covering the outflow graft at its origin with the pump (which we term extrinsic outflow graft obstruction at the bend relief). This process tends to be insidious, occurs late in the postoperative course, can be challenging to diagnose, and can result in significant morbidity and mortality. Herein, we provide a review of this complication and outline diagnostic, treatment, and preventive strategies.

15.
Artif Organs ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38887186

ABSTRACT

BACKGROUND: An inflammatory milieu after left ventricular assist device (LVAD) implantation is associated with multi-organ dysfunction and pre-operative heightened inflammatory state is associated with right ventricular failure after LVAD implantation. METHODS: We performed a retrospective analysis of 30 LVAD patients in our institution within the last 2 years for the development of fever and compared them to 30 non-LVAD open-heart surgery patients. RESULTS: Our results suggest that patients undergoing LVAD implantation are more likely to develop fever in the immediate post-operative period compared to other open-heart surgeries. This is independent of pharmacological treatment, age, or ethnical background. Females and obese patients were more likely to develop fever. CONCLUSION: Patients with right ventricular dysfunction, as demonstrated by elevated central venous pressure (CVP), had the strongest correlation with fever development. These results pose the question if there is a systemic inflammatory response-like phenomenon driven by increased right ventricular dysfunction.

16.
Article in English | MEDLINE | ID: mdl-38888980

ABSTRACT

AIM: To explore the knowledge and unmet informational needs of candidates for left ventricular assist devices (LVADs), as well as of patients, caregivers, and family members, by analyzing social media data from the MyLVAD.com website. METHODS AND RESULTS: A qualitative content analysis method was employed, systematically examining and categorizing forum posts and comments published on the MyLVAD.com website from March 2015 to February 2023. The data was collected using an automated script to retrieve threads from MyLVAD.com, focusing on genuine questions reflecting information and knowledge gaps. The study received approval from an ethics committee. The research team developed and continuously updated categorization matrices to organize information into categories and subcategories systematically. From 856 posts and comments analyzed, 435 contained questions representing informational needs, of which six main categories were identified: clothing, complications/adverse effects, LVAD pros and cons, self-care, therapy, and recent LVAD implantation. The self-care category, which includes managing the driveline site and understanding equipment functionality, was the most prominent, reflecting nearly half of the questions. Other significant areas of inquiry included complications/adverse effects and the pros and cons of LVAD. CONCLUSION: The analysis of social media data from MyLVAD.com reveals significant unmet informational needs among LVAD candidates, patients, and their support networks. Unlike traditional data, this social media-based research provides an unbiased view of patient conversations, offering valuable insights into their real-world concerns and knowledge gaps. The findings underscore the importance of tailored educational resources to address these unmet needs, potentially enhancing LVAD patient care.

17.
Methodist Debakey Cardiovasc J ; 20(1): 45-48, 2024.
Article in English | MEDLINE | ID: mdl-38855041

ABSTRACT

Left ventricular assist devices (LVAD) are frequently used in the management of end-stage heart failure, especially given the limited availability of donor hearts. The latest HeartMate 3 LVAD delivers non-physiological continuous flow (CF), although the impact on the aorta is not well established. We highlight a case of aortic aneurysm formation complicated by dissection formation that necessitated high-risk re-operative surgery in a patient post CF-LVAD.


Subject(s)
Aortic Aneurysm , Aortic Dissection , Blood Vessel Prosthesis Implantation , Heart Failure , Heart-Assist Devices , Humans , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Dissection/etiology , Aortic Dissection/physiopathology , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/etiology , Heart Failure/physiopathology , Heart Failure/etiology , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/surgery , Male , Ventricular Function, Left , Reoperation , Middle Aged , Aortography , Computed Tomography Angiography , Prosthesis Design
18.
J Card Fail ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38851449

ABSTRACT

BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (P = 0.89), nor was the pulmonary artery pulsatility index (PAPi) (P = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

19.
Eur J Case Rep Intern Med ; 11(6): 004549, 2024.
Article in English | MEDLINE | ID: mdl-38846674

ABSTRACT

Introduction: Ventricular septal defect (VSD) is a severe complication following acute myocardial infarction (MI) resulting from mechanical disruption of the interventricular septum due to extensive myocardial necrosis. Despite advances in management, the mortality rate approaches 50%. We report a case of a 58-year-old male with VSD following MI who was successfully treated with a delayed surgical approach after haemodynamic support using Impella. Case description: A 58-year-old man with type 2 diabetes mellitus and hypertension presented with three days of chest pain. Testing revealed late presenting acute anterior ischaemic infarction and left-to-right shunt in the apical ventricular septum. Urgent cardiac catheterisation showed near-total occlusion of the left anterior descending artery. An Impella CP® was placed before angioplasty with a drug-eluting stent to optimise haemodynamics. After a multidisciplinary discussion, the Impella CP® was upgraded to Impella 5.5®, and surgery was delayed allowing for scar formation. The patient remained in the intensive care unit, where he underwent physical therapy, showing improvements in exercise tolerance by the time of surgery. He underwent a left ventriculotomy with a successful repair via an endocardial patch 28 days after initial presentation. Post-operative recovery was uneventful, with the patient discharged five days later, reporting no physical limitations one month post-discharge. Conclusion: The successful management of VSD post-MI relies on interdisciplinary collaboration, careful timing of surgical intervention and the strategic use of mechanical support devices such as the Impella. This case highlights the potential for favourable outcomes when tailored treatment approaches are employed. LEARNING POINTS: Given the rarity of ventricular septal defects (VSD) post-myocardial infarction (MI), maintaining a high index of suspicion, particularly in patients with anterior infarcts and other high-risk features, is imperative for ensuring early recognition and management of this life-threatening complication.Surgical repair is the treatment of choice for VSD post-MI, offering improved survival rates, particularly when intervention is delayed to allow for myocardial scarring.Mechanical circulatory support devices, such as the Impella, can play a crucial role in bridging patients to surgical repair by providing temporary haemodynamic stabilisation. However, timing is vital, and early initiation of mechanical support can prevent the progression of cardiogenic shock and multi-organ failure.

20.
JACC Adv ; 3(2): 100817, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38939388

ABSTRACT

Background: Sex-based differences in clinical outcomes among patients with stroke related to left ventricular assist devices (LVADs) are not well described. Objectives: In this study, the authors examined differences in clinical characteristics and outcomes in men and women who had a stroke during LVAD hospitalization. Methods: The National Inpatient Sample from 2010 and 2019 was used to identify patients with stroke during LVAD hospitalization. Outcomes of interest include inpatient mortality and clinical complications among men vs women. Weighted logistic regression was used to determine the association of sex and outcomes. Adjustments were made for age and the Elixhauser comorbidity index. Results: In total, 35,820 patients underwent LVAD implantation (77% men), and 6.12% (n = 2,192) of patients experienced stroke. Women who had stroke were younger than men who had stroke (mean age in women was 51 years vs men 59 years, P < 0.001). Men with strokes had a higher burden of comorbidities than women. While there were no differences in the odds of ischemic stroke, women had higher odds of hemorrhagic stroke compared to men (OR: 1.49 [95% CI: 1.02-2.18]). Mortality in patients with LVAD who had stroke was significantly higher than in those without stroke. Between 2010 and 2019, stroke rates significantly increased among men, while the trend remained variable among women. Conclusions: In this national cohort, men had a higher comorbidity burden and had worsening stroke trends over the last decade compared to women. Women had fewer LVAD implants and a higher incidence of hemorrhagic stroke. Understanding the factors that contribute to sex-related outcome disparities among LVAD stroke patients is crucial in addressing these diverging trends.

SELECTION OF CITATIONS
SEARCH DETAIL
...