Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.641
Filter
1.
Article in English | MEDLINE | ID: mdl-39023717

ABSTRACT

The pandemic marked the beginning of an era of dynamic and rapid changes in the diagnosis of respiratory infections. Herein we describe Legionnaires' disease trend in the years 2016-2023 in a large Italian hospital showing how improvements in diagnostic algorithms impact on its detection.

2.
Environ Sci Pollut Res Int ; 31(32): 45234-45245, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38961023

ABSTRACT

Wastewater treatment plants (WWTPs) are suspected reservoirs of Legionella pneumophila (Lp). The required aeration and mixing steps lead to the emission and dispersion of bioaerosols potentially harboring Lp. The aim of the project is to evaluate municipal WWTPs as a possible source of legionellosis through the statistical analysis of case clusters. A space-time scanning statistical method was implemented in SaTScan software to identify and analyze WWTPs located within and close to spatiotemporal clusters of legionellosis detected in Quebec between 2016 and 2020. In parallel, WWTPs were ranked according to their pollutant load, flow rate and treatment type. These parameters were used to evaluate the WWTP susceptibility to generate and disperse bioaerosols. Results show that 37 of the 874 WWTPs are located inside a legionellosis cluster study zone, including six of the 40 WWTPs ranked most susceptible. In addition, two susceptible WWTPs located within an extended area of 2.5 km from the study zone (2.5-km buffer) were included, for a total of 39 WWTPs. The selected 39 WWTPs were further studied to document proximity of population, dominant wind direction, and surrounding water quality. Samples collected from the influent and the effluent of six selected WWTPs revealed the presence of Legionella spp. in 92.3% of the samples. Lp and Lp serogroupg 1 (Lp sg1) were detected below the limit of quantification in 69% and 46% of the samples, respectively. The presence of Legionella in wastewater and the novel statistical approach presented here provides information to the public health authorities regarding the investigation of WWTPs as a possible source of Legionella exposure, sporadic cases, and clusters of legionellosis.


Subject(s)
Environmental Monitoring , Legionellosis , Wastewater , Legionellosis/epidemiology , Humans , Quebec/epidemiology , Legionella pneumophila , Water Purification , Water Microbiology , Waste Disposal, Fluid
3.
mBio ; : e0082724, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38975782

ABSTRACT

Grazing of amoebae on microorganisms represents one of the oldest predator-prey dynamic relationships in nature. It represents a genetic "melting pot" for an ancient and continuous multi-directional inter- and intra-kingdom horizontal gene transfer between amoebae and its preys, intracellular microbial residents, endosymbionts, and giant viruses, which has shaped the evolution, selection, and adaptation of microbes that evade degradation by predatory amoeba. Unicellular phagocytic amoebae are thought to be the ancient ancestors of macrophages with highly conserved eukaryotic processes. Selection and evolution of microbes within amoeba through their evolution to target highly conserved eukaryotic processes have facilitated the expansion of their host range to mammals, causing various infectious diseases. Legionella and environmental Chlamydia harbor an immense number of eukaryotic-like proteins that are involved in ubiquitin-related processes or are tandem repeats-containing proteins involved in protein-protein and protein-chromatin interactions. Some of these eukaryotic-like proteins exhibit novel domain architecture and novel enzymatic functions absent in mammalian cells, such as ubiquitin ligases, likely acquired from amoebae. Mammalian cells and amoebae may respond similarly to microbial factors that target highly conserved eukaryotic processes, but mammalian cells may undergo an accidental response to amoeba-adapted microbial factors. We discuss specific examples of microbes that have evolved to evade amoeba predation, including the bacterial pathogens- Legionella, Chlamydia, Coxiella, Rickettssia, Francisella, Mycobacteria, Salmonella, Bartonella, Rhodococcus, Pseudomonas, Vibrio, Helicobacter, Campylobacter, and Aliarcobacter. We also discuss the fungi Cryptococcus, and Asperigillus, as well as amoebae mimiviruses/giant viruses. We propose that amoeba-microbe interactions will continue to be a major "training ground" for the evolution, selection, adaptation, and emergence of microbial pathogens equipped with unique pathogenic tools to infect mammalian hosts. However, our progress will continue to be highly dependent on additional genomic, biochemical, and cellular data of unicellular eukaryotes.

4.
Sci Rep ; 14(1): 16781, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39039267

ABSTRACT

Biofilms are known to be critical for Legionella settlement in engineered water systems and are often associated with Legionnaire's Disease events. One of the key features of biofilms is their heterogeneous three-dimensional structure which supports the establishment of microbial interactions and confers protection to microorganisms. This work addresses the impact of Legionella pneumophila colonization of a Pseudomonas fluorescens biofilm, as information about the interactions between Legionella and biofilm structures is scarce. It combines a set of meso- and microscale biofilm analyses (Optical Coherence Tomography, Episcopic Differential Interference Contrast coupled with Epifluorescence Microscopy and Confocal Laser Scanning Microscopy) with PNA-FISH labelled L. pneumophila to tackle the following questions: (a) does the biofilm structure change upon L. pneumophila biofilm colonization?; (b) what happens to L. pneumophila within the biofilm over time and (c) where is L. pneumophila preferentially located within the biofilm? Results showed that P. fluorescens structure did not significantly change upon L. pneumophila colonization, indicating the competitive advantage of the first colonizer. Imaging of PNA-labelled L. pneumophila showed that compared to standard culture recovery it colonized to a greater extent the 3-day-old P. fluorescens biofilms, presumably entering in VBNC state by the end of the experiment. L. pneumophila was mostly located in the bottom regions of the biofilm, which is consistent with the physiological requirements of both bacteria and confers enhanced Legionella protection against external aggressions. The present study provides an expedited methodological approach to address specific systematic laboratory studies concerning the interactions between L. pneumophila and biofilm structure that can provide, in the future, insights for public health Legionella management of water systems.


Subject(s)
Biofilms , Legionella pneumophila , Pseudomonas fluorescens , Biofilms/growth & development , Legionella pneumophila/physiology , Pseudomonas fluorescens/physiology , Legionella/physiology , Microscopy, Confocal , Tomography, Optical Coherence
5.
Front Mol Biosci ; 11: 1422034, 2024.
Article in English | MEDLINE | ID: mdl-39044841

ABSTRACT

Upon infection of host cells the Legionella pneumophila bacterium releases a multitude of effector enzymes into the host's cytoplasm that manipulate cellular host pathways, including the host-ubiquitination pathways. The effectors belonging to the SidE-family are involved in non-canonical phosphoribosyl serine ubiquitination (PR-ubiquitination) of host substrate proteins. This results in the recruitment of ER-remodeling proteins and the formation of a Legionella-containing vacuole which is crucial in the onset of legionnaires disease. PR-ubiquitination is a dynamic process reversed by other Legionella effectors called Dups. During PR-Ubiquitin phosphodiester hydrolysis Dups form a covalent intermediate with the phosphoribosyl ubiquitylated protein using its active site His67 residue. We envisioned that covalent probes to target Legionella effectors could be of value to study these effectors and contribute to deciphering the complex biology of Legionella infection. Hence we effectively installed a photo-activatable pyridinium warhead on the 5'-OH of triazole-linked ribosylated ubiquitin allowing crosslinking of the probe to the catalytic histidine residues in Legionella SidE or Dup enzymes. In vitro tests on recombinantly expressed DupA and SdeAPDE revealed that the probe was able to capture the enzymes covalently upon photo-activation.

6.
Pediatr Dermatol ; 2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39045799

ABSTRACT

Cutaneous Legionella infection is rare and primarily seen in immunosuppressed patients. Herein, we present a case of cutaneous and pulmonary legionellosis presenting with fever and erythematous subcutaneous nodules in a neonate with severe combined immunodeficiency. This case underscores the importance of considering this diagnosis and highlights the use of modern testing modalities to promptly diagnose and treat infections in immunocompromised patients.

7.
Cureus ; 16(6): e62066, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38989332

ABSTRACT

Legionella pneumonia is a severe form of pneumonia caused by the bacterium Legionella pneumophila. It often presents with atypical symptoms and can lead to complications such as rhabdomyolysis and acute kidney injury (AKI). Here, we report a case of Legionella pneumonia-induced rhabdomyolysis and AKI in a 32-year-old male. Laboratory investigations revealed elevated creatinine kinase levels and acute kidney injury. Further investigation confirmed Legionella pneumonia. The patient was promptly treated with appropriate antibiotics and supportive care, resulting in clinical improvement and resolution of rhabdomyolysis and AKI. This case underscores the importance of considering Legionella pneumonia as a potential cause of rhabdomyolysis and AKI, especially in patients with atypical pneumonia presentations.

8.
North Clin Istanb ; 11(3): 214-218, 2024.
Article in English | MEDLINE | ID: mdl-39005748

ABSTRACT

OBJECTIVE: Legionella pneumophila (Lp) is aerobic, non-spore forming Gram-negative bacteria, which is ubiquitous in freshwater habitats, such as rivers and hot springs, as well as colonizing artificial aquatic environments. The ability of Lp to grow intracellularly within pulmonary macrophages is a prerequisite for the development of infection. Therefore, macrolides can achieve appropriate therapeutic concentrations in eukaryotic cells, such as azithromycin. This study aimed to investigate the macrolides susceptibility of Lp. METHODS: Pre-flash water samples (n=143) were collected from the public buildings (hospitals and hotels) water system in Istanbul. Colonies were confirmed as Lp ST1, ST2-14, and non-pneumophila Lp using latex agglutination kit. RESULTS: 30 Lp were detected in hospital (n=23) and hotel (n=7) water systems using latex agglutination. Regardless of serotype and excluding strains without zone formation (≥256 mg/L), the main MIC values of azithromycin, erythromycin and clarithromycin were 0.61 mg/L (range 0.047-1 mg/L), 0.47 mg/L (range 0.047-1 mg/L) and 0.44 mg/L (range 0.047-1 mg/L), respectively. The MIC50 and MIC90 values for macrolides were 0.5 and 3 mg/L for azithromycin, respectively; 0.38 and 1 mg/L for erythromycin, respectively; and 0.5 and 1 mg/L for clarithromycin, respectively. We compared the MIC values of the strains for all antimicrobial agents tested without serotype discrimination. We did not find a significant difference between the MIC values of the antibiotics (p=0.16). CONCLUSION: Although the data obtained from our study do not fully reflect the breakpoints, further epidemiological studies are needed to standardize MIC values.

9.
J Egypt Public Health Assoc ; 99(1): 17, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39004690

ABSTRACT

BACKGROUND: Currently, tap water consumption is not highly preferred in Egypt and around the world. People prefer to consume bottled water because they believe that it is much safer and tastes better than tap water. Unfortunately, this preference can create an economic burden for many people, especially in developing countries. Clay pots can be used to provide cool, alkaline drinking water because of their porous micro-texture, which traps pollutants. This study aimed to investigate the use of clay pots to store tap water and its impact on the requirements for drinking water quality. This is done with the intent to decrease the need for bottled water as a means of offering a more sustainable and economical option. METHODS: In this study, the efficiency of clay pots as sustainable storage containers for drinking water was tested by measuring physicochemical parameters (pH, TDS, EC, turbidity, DO, ammonia, chloride, total hardness, Ca hardness, Mg hardness, chlorine, Zn, and CaCO3) and biological parameters (TPC and Legionella). RESULTS: After 7 days of storage, the quality of the water stored in clay pots met the standards set by the Egyptian law with a significant difference (p < 0.05) before and after the storage of water It was found that the dissolved oxygen increased from 6.17 ppm to 7.52 ppm after 7 days. As for total hardness, it declined from 195 to 178 ppm. There was also a significant drop in terms of TDS from 338 to 275 ppm. Furthermore, clay pots effectively filtered out both total viable bacteria and Legionella. CONCLUSION: This study proved the efficiency of using these containers with respect to some indicator values for tap water and tank water analysis. Clay pots are an excellent, cost-effective, and sustainable alternative for storing water.

10.
Appl Environ Microbiol ; : e0065824, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39016616

ABSTRACT

Legionella pneumophila is ubiquitous and sporadically infects humans causing Legionnaire's disease (LD). Globally, reported cases of LD have risen fourfold from 2000 to 2014. In 2016, Sydney, Australia was the epicenter of an outbreak caused by L. pneumophila serogroup 1 (Lpsg1). Whole-genome sequencing was instrumental in identifying the causal clone which was found in multiple locations across the city. This study examined the epidemiology of Lpsg1 in an urban environment, assessed typing schemes to classify resident clones, and investigated the association between local climate variables and LD outbreaks. Of 223 local Lpsg1 isolates, we identified dominant clones with one clone isolated from patients in high frequency during outbreak investigations. The core genome multi-locus sequence typing scheme was the most reliable in identifying this Lpsg1 clone. While an increase in humidity and rainfall was found to coincide with a rise in LD cases, the incidence of the major L. pneumophila outbreak clone did not link to weather phenomena. These findings demonstrated the role of high-resolution typing and weather context assessment in determining source attribution for LD outbreaks in urban settings, particularly when clinical isolates remain scarce.IMPORTANCEWe investigated the genomic and meteorological influences of infections caused by Legionella pneumophila in Sydney, Australia. Our study contributes to a knowledge gap of factors that drive outbreaks of legionellosis compared to sporadic infections in urban settings. In such cases, clinical isolates can be rare, and thus, other data are needed to inform decision-making around control measures. The study revealed that core genome multi-locus sequence typing is a reliable and adaptable technique when investigating Lpsg1 outbreaks. In Sydney, the genomic profile of Lpsg1 was dominated by a single clone, which was linked to numerous community cases over a period of 40 years. Interestingly, the peak in legionellosis cases during Autumn was not associated with this prevalent outbreak clone. Incorporating meteorological data with Lpsg1 genomics can support risk assessment strategies for legionellosis in urban environments, and this approach may be relevant for other densely populated regions globally.

11.
Ann Ig ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38989797

ABSTRACT

Introduction: The periodic monitoring of Legionella in hospital water networks allows preventive measures to be taken to avoid the risk of legionellosis to patients and healthcare workers. Study design: The aim of the study is to standardize a method for predicting the risk of Legionella contamination in the water supply of a hospital facility, by comparing Machine Learning, conventional and combined models. Methods: During the period July 2021- October 2022, water sampling for Legionella detection was performed in the rooms of an Italian hospital pavilion (89.9% of the total number of rooms). Fifty-eight parameters regarding the structural and environmental characteristics of the water network were collected. Models were built on 70% of the dataset and tested on the remaining 30% to evaluate accuracy, sensitivity, and specificity. Results: A total of 1,053 water samples were analyzed and 57 (5.4%) were positive for Legionella. Of the Machine Learning models tested, the most efficient had an input layer (56 neurons), hidden layer (30 neurons), and output layer (two neurons). Accuracy was 93.4%, sensitivity was 43.8%, and specificity was 96%. The regression model had an accuracy of 82.9%, sensitivity of 20.3%, and specificity of 97.3%. The combination of the models achieved an accuracy of 82.3%, sensitivity of 22.4%, and specificity of 98.4%. The most important parameters that influenced the model results were the type of water network (hot/cold), the replacement of filter valves, and atmospheric temperature. Among the models tested, Machine Learning obtained the best results in terms of accuracy and sensitivity. Conclusions: Future studies are required to improve these predictive models by expanding the dataset using other parameters and other pavilions of the same hospital.

12.
G3 (Bethesda) ; 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39028840

ABSTRACT

To remodel their hosts and escape immune defenses, many pathogens rely on large arsenals of proteins (effectors) that are delivered to the host cell using dedicated translocation machinery. Effectors hold significant insight into the biology of both the pathogens that encode them and the host pathways that they manipulate. One of the most powerful systems biology tools for studying effectors is the model organism, Saccharomyces cerevisiae. For many pathogens, the heterologous expression of effectors in yeast is growth inhibitory at a frequency much higher than housekeeping genes, an observation ascribed to targeting conserved eukaryotic proteins. Abrogation of yeast growth inhibition has been used to identify bacterial suppressors of effector activity, host targets, and functional residues and domains within effector proteins. We present here a yeast-based method for enriching for informative, in-frame, missense mutations in a pool of random effector mutants. We benchmark this approach against three effectors from Legionella pneumophila, an intracellular bacterial pathogen that injects a staggering >330 effectors into the host cell. For each protein, we show how in silico protein modeling (AlphaFold2) and missense-directed mutagenesis can be combined to reveal important structural features within effectors. We identify known active site residues within the metalloprotease RavK, the putative active site in SdbB, and previously unidentified functional motifs within the C-terminal domain of SdbA. We show that this domain has structural similarity with glycosyltransferases and exhibits in vitro activity consistent with this predicted function.

13.
Pathogens ; 13(7)2024 Jul 03.
Article in English | MEDLINE | ID: mdl-39057790

ABSTRACT

Cu is an antimicrobial that is commonly applied to premise (i.e., building) plumbing systems for Legionella control, but the precise mechanisms of inactivation are not well defined. Here, we applied a suite of viability assays and mass spectrometry-based proteomics to assess the mechanistic effects of Cu on L. pneumophila. Although a five- to six-log reduction in culturability was observed with 5 mg/L Cu2+ exposure, cell membrane integrity only indicated a <50% reduction. Whole-cell proteomic analysis revealed that AhpD, a protein related to oxidative stress, was elevated in Cu-exposed Legionella relative to culturable cells. Other proteins related to cell membrane synthesis and motility were also higher for the Cu-exposed cells relative to controls without Cu. While the proteins related to primary metabolism decreased for the Cu-exposed cells, no significant differences in the abundance of proteins related to virulence or infectivity were found, which was consistent with the ability of VBNC cells to cause infections. Whereas the cell-membrane integrity assay provided an upper-bound measurement of viability, an amoebae co-culture assay provided a lower-bound limit. The findings have important implications for assessing Legionella risk following its exposure to copper in engineered water systems.

14.
J Hosp Infect ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38960042

ABSTRACT

BACKGROUND: National and international guidance provides advice on maintenance and management of water systems in healthcare buildings, however, healthcare-associated waterborne infections (HAWI) are increasing. This narrative review identifies parameters critical to water quality in healthcare buildings and assesses if remote sensor monitoring can deliver safe water systems thus reducing HAWI. METHOD: A narrative review was performed using the following search terms 1) consistent water temperature AND waterborne pathogen control OR nosocomial infection 2) water throughput AND waterborne pathogen control OR nosocomial infection 3) remote monitoring of in-premise water systems AND continuous surveillance for temperature OR throughput OR flow OR use. Databases employed were PubMed, CDSR (Clinical Study Data Request) and DARE (Database of Abstracts of Reviews of Effects) from Jan 2013 - Mar 2024. FINDINGS: Single ensuite-patient rooms, expansion of wash-hand basins, widespread glove use, alcohol gel and wipes have increased water system stagnancy resulting in amplification of waterborne pathogens and transmission risk of Legionella, Pseudomonas and Non-Tuberculous Mycobacteria. Manual monitoring does not represent temperatures across large complex water systems. This review deems that multiple point continuous remote sensor monitoring is effective at identifying redundant and low use outlets, hydraulic imbalance and inconsistent temperature delivery across in-premise water systems. CONCLUSION: As remote monitoring becomes more common there will be greater recognition of failures in temperature control, hydraulics and balancing in water systems and there remains much to learn as we adopt this developing technology within our hospitals.

15.
Microbiol Spectr ; : e0071324, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38953325

ABSTRACT

Monitoring the levels of opportunistic pathogens in drinking water is important to plan interventions and understand the ecological niches that allow them to proliferate. Quantitative PCR is an established alternative to culture methods that can provide a faster, higher-throughput, and more precise enumeration of the bacteria in water samples. However, PCR-based methods are still not routinely applied for Legionella monitoring, and techniques, such as DNA extraction, differ notably between laboratories. Here, we quantify the impact that DNA extraction methods had on downstream PCR quantification and community sequencing. Through a community science campaign, we collected 50 water samples and corresponding shower hoses, and compared two commonly used DNA extraction methodologies to the same biofilm and water phase samples. The two methods showed clearly different extraction efficacies, which were reflected in both the quantity of DNA extracted and the concentrations of Legionella enumerated in both the matrices. Notably, one method resulted in higher enumeration in nearly all samples by about one order of magnitude and detected Legionella in 21 samples that remained undetected by the other method. 16S rRNA amplicon sequencing revealed that the relative abundance of individual taxa, including sequence variants of Legionella, significantly varied depending on the extraction method employed. Given the implications of these findings, we advocate for improvement in documentation of the performance of DNA extraction methods used in drinking water to detect and quantify Legionella, and characterize the associated microbial community.IMPORTANCEMonitoring for the presence of the waterborne opportunistic pathogen Legionella is important to assess the risk of infection and plan remediation actions. While monitoring is traditionally carried on through cultivation, there is an ever-increasing demand for rapid and high-throughput molecular-based approaches for Legionella detection. This paper provides valuable insights on how DNA extraction affects downstream molecular analysis such as the quantification of Legionella through droplet digital PCR and the characterization of natural microbial communities through sequencing analysis. We analyze the results from a risk-assessment, legislative, and ecological perspective, showing how initial DNA processing is an important step to take into account when shifting to molecular-based routine monitoring and discuss the central role of consistent and detailed reporting of the methods used.

16.
J Microbiol Methods ; 223: 106977, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38936430

ABSTRACT

A new innovative method, MICA Legionella, allows for the automatic enumeration of Legionella pneumophila in domestic water samples in 2 days, with a detection limit of 2 CFU per test portion. Here we show that it gives equivalent results to those obtained by the French standard method NF T90-431 in 7 to 15 days.


Subject(s)
Legionella pneumophila , Water Microbiology , Legionella pneumophila/isolation & purification , France , Bacterial Load/methods , Colony Count, Microbial/methods , Time Factors , Bacteriological Techniques/methods
17.
Cell Mol Life Sci ; 81(1): 249, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38836877

ABSTRACT

Protein ubiquitination is one of the most important posttranslational modifications (PTMs) in eukaryotes and is involved in the regulation of almost all cellular signaling pathways. The intracellular bacterial pathogen Legionella pneumophila translocates at least 26 effectors to hijack host ubiquitination signaling via distinct mechanisms. Among these effectors, SidC/SdcA are novel E3 ubiquitin ligases with the adoption of a Cys-His-Asp catalytic triad. SidC/SdcA are critical for the recruitment of endoplasmic reticulum (ER)-derived vesicles to the Legionella-containing vacuole (LCV). However, the ubiquitination targets of SidC/SdcA are largely unknown, which restricts our understanding of the mechanisms used by these effectors to hijack the vesicle trafficking pathway. Here, we demonstrated that multiple Rab small GTPases and target soluble N-ethylmaleimide-sensitive factor attachment protein receptors (SNARE) proteins are bona fide ubiquitination substrates of SidC/SdcA. SidC/SdcA-mediated ubiquitination of syntaxin 3 and syntaxin 4 promotes their unconventional pairing with the vesicle-SNARE protein Sec22b, thereby contributing to the membrane fusion of ER-derived vesicles with the phagosome. In addition, our data reveal that ubiquitination of Rab7 by SidC/SdcA is critical for its association with the LCV membrane. Rab7 ubiquitination could impair its binding with the downstream effector Rab-interacting lysosomal protein (RILP), which partially explains why LCVs avoid fusion with lysosomes despite the acquisition of Rab7. Taken together, our study reveals the biological mechanisms employed by SidC/SdcA to promote the maturation of the LCVs.


Subject(s)
Legionella pneumophila , Phagosomes , SNARE Proteins , Ubiquitination , rab GTP-Binding Proteins , Legionella pneumophila/metabolism , Humans , Phagosomes/metabolism , Phagosomes/microbiology , SNARE Proteins/metabolism , rab GTP-Binding Proteins/metabolism , Bacterial Proteins/metabolism , Bacterial Proteins/genetics , Animals , Qa-SNARE Proteins/metabolism , Ubiquitin-Protein Ligases/metabolism , Ubiquitin-Protein Ligases/genetics , Vacuoles/metabolism , Vacuoles/microbiology , HEK293 Cells , Mice , rab7 GTP-Binding Proteins/metabolism , Monomeric GTP-Binding Proteins/metabolism , Endoplasmic Reticulum/metabolism
18.
BMC Public Health ; 24(1): 1491, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38834949

ABSTRACT

BACKGROUND: Infection by Legionella bacteria is a risk to elderly individuals in health care facilities and should be managed by preventing bacterial proliferation in internal water systems. Norwegian legislation calls for a mandatory Legionella-specific risk assessment with the subsequent introduction of an adapted water management programme. The present study investigates adherence to legislation and guidelines on Legionella control and prevention in Norwegian nursing homes. METHODS: A cross-sectional survey was distributed to Norwegian municipalities to investigate the status of Legionella specific risk assessments of internal water distribution systems and the introduction of water management programmes in nursing homes. RESULTS: A total of 55.1% (n = 228) of the participating nursing homes had performed Legionella-specific risk assessments, of which 55.3% (n = 126) stated that they had updated the risk assessment within the last year. 96.5% introduced a water management programme following a risk assessment, whereas 59.6% of the ones without a risk assessment did the same. Nursing homes with risk assessments were more likely to monitor Legionella levels than those without (61.2% vs 38.8%), to remove dead legs (44.7% vs 16.5%), and to select biocidal preventive treatment over hot water flushing (35.5% vs 4.6%). CONCLUSIONS: This study presents novel insight into Legionella control in Norway, suggesting that adherence to mandatory risk assessment in nursing homes is moderate-low. Once performed, the risk assessment seems to be advantageous as an introduction to future Legionella prevention in terms of the scope and contents of the water management programme.


Subject(s)
Guideline Adherence , Nursing Homes , Water Microbiology , Norway , Cross-Sectional Studies , Nursing Homes/standards , Nursing Homes/legislation & jurisprudence , Humans , Guideline Adherence/statistics & numerical data , Water Microbiology/standards , Legionella , Risk Assessment , Legionellosis/prevention & control , Water Supply/standards , Water Supply/legislation & jurisprudence , Aged
19.
Przegl Epidemiol ; 78(1): 44-55, 2024 Jun 07.
Article in English, Polish | MEDLINE | ID: mdl-38904311

ABSTRACT

BACKGROUND: Legionnaires' disease is a type of severe pneumonia caused by Legionella bacteria. The case fatality rate in this disease is 5-10%. People with various comorbidities, smokers and the elderly are at greater risk of developing the disease. OBJECTIVE: The aim of the work is to present the results of an epidemiological investigation into the outbreak of Legionnaires' disease that occurred in the city of Rzeszów and the surrounding area in August and September 2023 and to present the threat related to the presence of Legionella bacteria in water supply installations and networks. MATERIAL AND METHODS: The material for this publication was data from an epidemiological investigation conducted in the outbreak of Legionnaires disease in Rzeszów in 2023. RESULTS: Epidemiological investigation revealed 165 cases of Legionnaires' disease in the outbreak, including 152 confirmed cases and 13 probable cases. The case fatality rate in a legionellosis outbreak was 15%. Environmental tests were carried out in residential and public buildings and industrial installations during the investigation. As part of environmental tests, 187 water samples were collected, including 87 warm water samples. CONCLUSIONS: The outbreak of Legionnaires' disease in the city of Rzeszów draws attention to the potential threat from the Legionella bacteria to the health and life of especially elderly people suffering from chronic diseases. The environmental tests carried out confirmed the highest number of Legionella bacteria at medium and high levels in water samples taken in the private apartments of sick people. Despite the lack of strict legal regulations clearly specifying the obligations regarding periodic disinfection of internal hot water supply installations, cooperation with their owners should be undertaken to enforce plans and actions in this area.


Subject(s)
Disease Outbreaks , Legionnaires' Disease , Water Microbiology , Humans , Legionnaires' Disease/epidemiology , Disease Outbreaks/statistics & numerical data , Male , Female , Aged , Poland/epidemiology , Middle Aged , Adult , Water Supply , Aged, 80 and over , Legionella pneumophila/isolation & purification , Legionella/isolation & purification
20.
Front Cell Infect Microbiol ; 14: 1380312, 2024.
Article in English | MEDLINE | ID: mdl-38836055

ABSTRACT

Legionella, one of the main pathogens that causes community-acquired pneumonia, can lead to Legionella pneumonia, a condition characterized predominantly by severe pneumonia. This disease, caused by the bacterium Legionella pneumophila, can quickly progress to critical pneumonia and is often associated with damage to multiple organs. As a result, it requires close attention in terms of clinical diagnosis and treatment. Omadacycline, a new type of tetracycline derivative belonging to the aminomethylcycline class of antibiotics, is a semi-synthetic compound derived from minocycline. Its key structural feature, the aminomethyl modification, allows omadacycline to overcome bacterial resistance and broadens its range of effectiveness against bacteria. Clinical studies have demonstrated that omadacycline is not metabolized in the body, and patients with hepatic and renal dysfunction do not need to adjust their dosage. This paper reports a case of successful treatment of Legionella pneumonia with omadacycline in a patient who initially did not respond to empirical treatment with moxifloxacin. The patient also experienced electrolyte disturbance, as well as dysfunction in the liver and kidneys, delirium, and other related psychiatric symptoms.


Subject(s)
Anti-Bacterial Agents , Legionella pneumophila , Legionnaires' Disease , Tetracyclines , Humans , Tetracyclines/therapeutic use , Anti-Bacterial Agents/therapeutic use , Anti-Bacterial Agents/pharmacology , Legionnaires' Disease/drug therapy , Legionnaires' Disease/microbiology , Legionella pneumophila/drug effects , Treatment Outcome , Male , Community-Acquired Infections/drug therapy , Community-Acquired Infections/microbiology , Moxifloxacin/therapeutic use , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...