Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.941
Filter
1.
Article in English | MEDLINE | ID: mdl-39077550

ABSTRACT

Objectives: We aimed to identify independent factors for intraoperative endoscopic lens cloudiness during gastric and colorectal endoscopic submucosal dissections, investigate the effectiveness of Cleastay, an endoscope anti-fog solution, and examine factors associated with severe submucosal fat deposition. Methods: A total of 220 patients who underwent gastric or colorectal endoscopic submucosal dissections in two institutions between January 2022 and October 2023 were included. Significant factors related to cloudiness were determined using univariate and multivariate analyses. Patient background and tumor characteristics related to severe submucosal fat deposition were investigated, and the degree of intraoperative endoscopic lens cloudiness and outcomes were compared between the Cleash and Cleastay groups. Results: In the multivariate analysis, factors increasing lens cloudiness included long procedure time (odds ratio [OR], 17.51; 95% confidence interval [CI], 1.52-202.08), stomach (vs. colon; OR, 5.08; 95% CI, 1.99-12.96), and severe submucosal fat deposition (OR, 12.19; 95% CI, 5.02-29.60). Conversely, the use of Cleastay (vs. Cleash; OR, 0.066; 95% CI, 0.021-0.21) was identified as a factor reducing cloudiness. Location analysis revealed that severe submucosal fat deposition was more common in the upper stomach and right colon. Conclusions: It was suggested that Cleastay is more useful for endoscopic submucosal dissection of the upper stomach and right colon, where severe submucosal fat deposition is expected.

2.
BMC Ophthalmol ; 24(1): 320, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090592

ABSTRACT

BACKGROUND: The visual performance and the optical quality of a segmental refractive extended depth-of-focus (EDoF) intraocular lens (IOL) were evaluated in a prospective, single-arm, single-center study. METHODS: A total of 20 patients (40 eyes) after bilateral implantation of the refractive segmental EDoF Acunex Vario AN6V were included. Assessment procedure: refraction outcome, monocular and binocular uncorrected (UCVA) and distance-corrected visual acuity (DCVA), defocus curve, contrast sensitivity (CS), higher-order aberrations (HOAs) and patient satisfaction were evaluated 1 and 3 months after surgery. RESULTS: At 3-month follow-up, mean spherical equivalent was - 0.23 ± 0.32 D. Binocular uncorrected distance visual acuity (VA) at distance, intermediate and near was - 0.08 ± 0.06 logMAR at 4 m, -0.03 ± 0.06 logMAR at 66 cm and 0.16 ± 0.06 logMAR at 40 cm, respectively. The binocular defocus curve showed a VA better than 0.20 logMAR over a range from + 1.50 to - 2.45 D. Contrast sensitivity aligned with monofocal lenses, highlighting the lens's clinical value. Aberrometry showed minimal changes in corneal aberrations. NEI-RQL-42-Questionnaire showed a high patient satisfaction for daily activities and revealed reduced dependence on glasses, particularly for near and intermediate vision. The Acunex Vario AN6V demonstrated minimal dysphotopsias, making it a promising option for those seeking spectacle independence. CONCLUSION: This segmental refractive EDoF IOL provides a high degree of spectacle independence for far and intermediate distances with functional near VA. Although inducing residual coma aberrations, it showed subjectively good results with little dysphotopsias. TRIAL REGISTRATION: This study protocol was reviewed and approved by ethics committee of Charité University, Berlin, Germany, with approval number EA4/126/20.


Subject(s)
Contrast Sensitivity , Lenses, Intraocular , Patient Satisfaction , Pseudophakia , Refraction, Ocular , Visual Acuity , Humans , Visual Acuity/physiology , Female , Prospective Studies , Male , Middle Aged , Refraction, Ocular/physiology , Aged , Contrast Sensitivity/physiology , Pseudophakia/physiopathology , Prosthesis Design , Phacoemulsification , Lens Implantation, Intraocular/methods , Depth Perception/physiology , Vision, Binocular/physiology , Follow-Up Studies
3.
Technol Health Care ; 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39093091

ABSTRACT

BACKGROUND: Soft ureteroscopic holmium laser lithotripsy is becoming increasingly popular as the preferred method for treating mid-to-lower ureteral stones. Studies have indicated that the size, composition, hardness, and fragility of the stones can impact the treatment's effectiveness. OBJECTIVE: To explore the relationship between stone volume, average CT value and operation time and efficiency before ureteral soft lens laser lithotripsy. METHODS: Our study on 126 patients undergoing ureteroscopic holmium laser lithotripsy for ureteral calculi from May 2020 to January 2022 categorized them into groups based on stone volume and CT value. We compared surgical outcomes and analyzed correlations between stone characteristics, operation parameters, and stone clearance rate to identify independent risk factors influencing treatment efficacy. RESULTS: Group A demonstrated significantly shorter operation durations and lower blood loss compared to Group B, along with higher single stone clearance rates and fewer postoperative complications. Similarly, Group C exhibited shorter operation times, reduced blood loss, higher stone clearance rates, and lower complication rates than Group D. Preoperative stone volume and CT value correlated positively with operation time and stone clearance rate, with both factors identified as independent risk factors affecting ureteral stone clearance following holmium laser lithotripsy. CONCLUSION: The stone volume and average CT value before ureteral soft lens laser lithotripsy show a positive correlation with operation time and efficiency, indicating that larger stone volumes and higher CT values lead to slower lithotripsy speeds and reduced operation efficiency. Furthermore, preoperative stone volume and average CT value are identified as independent risk factors for residual stones.

4.
Br J Ophthalmol ; 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39054053

ABSTRACT

AIMS: To assess the association between statin use and cataract surgery according to different statin treatment durations in patients with different cardiovascular risk profiles. METHODS AND RESULTS: We performed a nested case-control study using Danish registries, covering the period from 1 January 1996 to 31 December 2020. We defined cases as surgically treated cataract patients, matched in a 1:1 ratio by sex and age with controls not undergoing cataract surgery. The exposure of interest was statin use in different durations (1, 5 and 10 years) compared with never use of statins. Conditional logistic regression provided adjusted HRs and corresponding 95% CIs in subgroups defined by established atherosclerotic cardiovascular disease, diabetes, hypertension and individuals without these comorbidities. We identified 505 150 cataract surgery cases and found no increased HR of cataract surgery with statin treatment at any duration in any of the subgroups with established atherosclerotic cardiovascular disease, diabetes or hypertension. CONCLUSION: Our findings do not support a possible association between long-term statin use and cataract in patients with established atherosclerotic cardiovascular disease, diabetes or hypertension. Although we found an association between statin use and cataract in individuals without these comorbidities, increasing durations of statin use did not yield higher cataract surgery rates.

5.
Cureus ; 16(6): e62963, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39044865

ABSTRACT

Purpose The objective of this study is to know the effect of blue light filter (BF) intraocular lenses (IOL) on colour vision of Sudanese patiens as BF IOLs are relatively new in Sudan and its effect on Sudanese patients is not yet studied. Methods  This was a descriptive cross-sectional observational study. Data collection was done through interview and pretested structured questionnaire containing three sections: (i) personal data, (ii) past medical and ocular surgical history, and (iii) visual acuity (VA), the anterior and posterior segment exam result, and the D15 photopic color vision test result. Results In this study, 206 eyes of 103 patients were enrolled. Of them, 57 (55.3%) were females and 46 (44.7 %) were males. The mean age of the participants was 58.38 years±11.488 (SD). Furthermore, 81 patients (78.64%) achieved normal D15 color vision test results, while 22 patients (21.4%) had abnormal results. There was a significant effect (P=.00) on photopic color vision perception. Finally, the gender-wise performance showed an insignificant difference (P=.933) with 78.3% of the males having normal D15 color vision test and the females having slightly better results with 78.9 %.  Conclusions The results suggested that implantation of BF IOLs has a significant effect on photopic color vision perception.

6.
Rom J Ophthalmol ; 68(2): 170-172, 2024.
Article in English | MEDLINE | ID: mdl-39006324

ABSTRACT

Aim: To describe the case of a patient with Marfan syndrome who had bilateral superonasal lens subluxation. Method: The case of a male patient, aged 18, who complained of having impaired vision in both eyes (BE) since he was a toddler, was presented. On examination of the patient, features suggestive of Marfan syndrome were revealed, as well as bilateral intraocular lens subluxation. Results: The patient was refracted and glasses were recommended, which improved his vision. The patient was referred to the cardiology, orthopedic, and dental departments for a multidisciplinary approach to prevent complications and further management. Discussion: Lens subluxation is frequently presented as a primary clinical manifestation of Marfan syndrome. It can vary from asymptomatic, which is seen only after pupillary dilation, to significant subluxation, in which the equator of the lens in the pupillary axis causes diplopia or decreased vision. Conclusion: This case underscored the importance of considering the rare feature of Marfan syndrome.


Subject(s)
Lens Subluxation , Marfan Syndrome , Visual Acuity , Humans , Marfan Syndrome/complications , Marfan Syndrome/diagnosis , Lens Subluxation/etiology , Lens Subluxation/diagnosis , Male , Adolescent
7.
Clin Optom (Auckl) ; 16: 157-167, 2024.
Article in English | MEDLINE | ID: mdl-39050806

ABSTRACT

Purpose: To explore links between subjective comfort and vision in habitual multifocal soft contact lens (MFCL) wearers when refit with daily disposable MFCLs, to determine which factors are relevant for success with MFCLs and evaluate consistency between MFCLs of different designs. Patients and Methods: This work examined subjective measures in a randomised, participant masked, bilateral wear crossover study at five optometry practices. Fifty-eight habitual MFCL wearers wore stenfilcon A multifocal (stenA-MF; CooperVision Inc) and delefilcon A multifocal (delA-MF; Alcon) for two-weeks. Subjective ratings included satisfaction with comfort and vision and agreement questions. Results: Agreement with "I would like to wear this MFCL in the future" was taken to indicate success with each MFCL; agreement was significantly higher with stenA-MF. There was strong correlation between agreement responses for "I would like to wear this MFCL in the future" and "MFCL met my needs for vision" with both lenses (p<0.01). However, it was only with stenA-MF, which had higher agreement responses to both statements (p<0.05), that responses to these two statements correlated with satisfaction with end-of-day (EOD) comfort (p<0.01). These differences in correlations between the two lenses are seemingly driven by greater satisfaction with stenA-MF for near and intermediate vision (p<0.05). Conclusion: Subjective vision and comfort were only correlated when vision met the needs of most participants. Meeting participants' needs for vision correlated strongly with wanting to wear a MFCL. Results indicate that meeting vision needs is more important than meeting comfort needs when influencing whether presbyopic patients continue wearing MFCLs.

8.
J Synchrotron Radiat ; 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39042577

ABSTRACT

The phase problem in the context of focusing synchrotron beams with X-ray lenses is addressed. The feasibility of retrieving the surface error of a lens system by using only the intensity of the propagated beam at several distances is demonstrated. A neural network, trained with a few thousand simulations using random errors, can predict accurately the lens error profile that accounts for all aberrations. It demonstrates the feasibility of routinely measuring the aberrations induced by an X-ray lens, or another optical system, using only a few intensity images.

10.
Semin Ophthalmol ; : 1-7, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39039754

ABSTRACT

BACKGROUND: The capsular tension ring is a novel assistant tool for cataract surgery; however, controversy exists in its co-implantation. The potential for hyperopic or myopic shift resulting from the co-implantation of the capsular tension ring and intraocular lens remains unclear. This study aimed to determine the postoperative refractive prediction error and the direction of refractive shift in cataract patients who underwent capsular tension ring co-implantation. METHODS: We conducted a systematic review and meta-analysis,searching electronic databases for studies of individuals diagnosed with cataracts receiving surgery with or without capsular tension ring implantation. Systematic searches were performed based on five databases: PubMed, Cochrane Library, Web of Science, Medline, and China National Knowledge Infrastructure. The primary outcome was the mean arithmetic refractive prediction error. Secondary outcomes were mean absolute refractive prediction error and the number of eyes within a certain refractive prediction error range. We applied a fixed-effectsmodel to pool effect sizes across trials using weighted mean differences (WMD) and risk ratios (RR) with their 95% confidence intervals (95% CI). Statistical heterogeneity scores were assessed with the I2statistic. RESULTS: A total of 407 affected eyes were included in eight independent clinical studies. Meta-analysis suggested significant differences both in short-term (≤1 month) co-implantation (WMD = 0.16, p < .001, 95% CI: -0.13 ~ 0.19) and long-term (≥3 months) co-implantation between the capsular tension ring co-implantation group and the control group (WMD = 0.19, p < .001, 95% CI: 0.15 ~ 0.23). However, no significant difference was observed in the high myopia subgroup whether capsular tension ring co-implantation (WMD = 0.03, p = .083, 95% CI: -0.27 ~ 0.34). Heterogeneity was not found among the studies. CONCLUSION: Compared to simple intraocular lens implantation, capsular tension ring co-implantation is more susceptible to developing hyperopic shifts in non-myopic cataract patients, probably related to anterior chamber depth. It requires careful consideration by clinicians when determining the target diopter preoperatively. However, interpretation is limited, because there is a lack of studies available for analysis. There still needs to be additional studies to expand the evidence base.

11.
Int J Retina Vitreous ; 10(1): 47, 2024 Jul 07.
Article in English | MEDLINE | ID: mdl-38972966

ABSTRACT

BACKGROUND: Dislocated IOL exchange conventionally involves manipulation within the anterior chamber which risks secondary injury to anterior chamber structures. We describe and evaluate a 4-haptic IOL rescue technique that avoids entering the anterior chamber and thus minimizes post operative inflammation, astigmatism and recovery time relative to conventional IOL explantation and replacement techniques. METHODS: Retrospective, non-randomized, interventional study of all patients undergoing 4-haptic IOL rescue performed by two independent vitreoretinal surgeons at a single UK centre over two years. SURGICAL TECHNIQUE: A limited peritomy is performed with four 25-gauge scleral ports placed to enable use of two forceps, an infusion and a chandelier. A further four 27-gauge sclerotomies are symmetrically placed on the nasal and temporal sclera at 3 mm from the limbus with a 5 mm vertical separation on either side. A pars plana vitrectomy is performed followed by chandelier illuminated, bimanual cleaning of the dislocated IOL using 27-gauge serrated forceps. Gore-tex sutures are threaded through the IOL islets within the vitreous cavity and externalized through the sclerotomies for scleral re-fixation followed by conjunctival closure. RESULTS: Seven patients underwent IOL recycling with Gore-Tex suture scleral re-fixation. All procedures were successful in repositioning the IOLs, with all patients satisfied with post-operative outcome. Mean (standard deviation) time to IOL dislocation was 13 (3) years. Median visual acuity significantly improved post-operatively from 0.85 logMAR (Interquartile Range [IQR]: 0.2-2.1) to 0.07 (0.02-0.60) logMAR (p = 0.02). No significant post-operative complications were noted apart from persistent cystoid macular oedema in one patient non-compliant with post-operative treatment. CONCLUSIONS: Transscleral refixation using Gore-Tex suture is an effective, safe and practical approach in the management of dislocated 4-piece IOLs.

12.
Clin Ophthalmol ; 18: 1921-1932, 2024.
Article in English | MEDLINE | ID: mdl-38978835

ABSTRACT

Purpose: Any new intraocular lens (IOL) on the market claims to outperform competitors. We aimed to estimate the modulation transfer function (MTF) for different defocus of a novel refractive enhanced depth of focus (EDoF) IOL and the simulated visual acuity over this range of vision. Further, we analyzed the wavefront pattern produced by this IOL to reveal the function of the IOL's optics. Methods: For the novel TECNIS® PureSee® (ZEN00V) IOL, through frequency and through focus MTF were recorded on the optical bench (ISO-2 Cornea 0.28 µm, 546 nm). MTFa and the simulated visual acuity were calculated for different defocus. Apertures of 3 mm and 4.5 mm were applied. Higher order aberrations of the IOLs' optics were recorded and analyzed. Results: PureSee® IOL demonstrated a considerable depth of focus of about 1.7 D at the spectacle plane and a continuous simulated visual acuity over this range of defocus. For the 4.5 mm aperture, near focus depth was reduced, yet far distance MTF was even better. Higher order aberrations revealed increased primary and secondary spherical aberrations. Conclusion: Optical bench results suggest that the new ZEN00V matches the clinical criteria of an EDoF IOL by an increased range of vision and is far distance dominant for an enlarged pupil. This behaviour seems to be due to subtle power changes in the central optics that produce a complex modification of wavefront.

13.
Semin Ophthalmol ; : 1-5, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38984920

ABSTRACT

PURPOSE: To assess intra-operative complications and feasibility of removing crystalline lens fragments from the vitreous cavity through a limbal incision compared to a pars plana approach. DESIGN: Retrospective cohort study. SUBJECTS: 16 eyes underwent phacofragmentation via a limbal approach (Group A) and 9 eyes through a pars plana approach (Group B) at an academic center over a 10-year period. METHODS: We collected pre-operative, intra-operative, and post-operative data. We compared rates of intraoperative complications, including corneal wound burn, iris or capsular damage, retinal tears, and hemorrhage, and recorded post-operative BCVA and IOP measurements at the one-month post-operative appointment. We also compared rates of post-operative complications, including corneal edema, choroidal detachment, or retinal detachment. MAIN OUTCOME MEASURES: Primary outcomes of the study were the rates of intraoperative complications and the feasibility of crystalline lens removal with the limbal approach. We defined the latter outcome as the ability to complete lens removal without switching to the pars plana route. RESULTS: Mean BCVA for group A was 1.6, and for group B was 2.0 (p = .19). There was no significant difference between the two groups in the incidence of intraoperative complications, including corneal wound burn, iris damage, anterior capsular tear, iatrogenic retinal tear, or suprachoroidal hemorrhage (p > .99). There was no significant difference in the incidence of intra-operative vitreous hemorrhage (p = .36). Additionally, there was no significant difference in post-operative corneal edema (p = .27), choroidal detachment (p = .52), or retinal detachment (p > .99). The mean post-operative BCVA was 1.0 in group A and 1.0 in group B (p = .75). We completed all cases in group A using the limbal approach without switching to the pars plana route. CONCLUSION: Phacofragmentation through a limbal incision provides a feasible option for dropped nuclear fragment removal and is not associated with a higher risk of complications than the pars plana route.

14.
BMC Ophthalmol ; 24(1): 318, 2024 Jul 30.
Article in English | MEDLINE | ID: mdl-39080583

ABSTRACT

PURPOSE: Measurement of corneal endothelial cells is critical for postoperative evaluation of phakic intraocular lens (pIOL) surgery. However, inter-instrument differences in corneal endothelial cell density (ECD) after pIOL implantation have not yet been reported. This study aimed to compare automated corneal endothelial cell analysis between CellChek-20 (Konan Medical, Hyogo, Japan) and EM-4000 (Tomey, Nagoya, Japan) in healthy and postoperative eyes with pIOL. METHODS: We retrospectively analyzed 154 healthy and 236 postoperative eyes after pIOL surgery. Endothelial cell measurements were performed using CellChek-20 and EM-4000 with autofocusing and automated image analysis. ECD, percentage of hexagonal cells (HEX), coefficient of variation in cell size (CoV), and central corneal thickness (CCT) were compared between the two devices. RESULTS: The ECDs of the two devices were highly correlated in both healthy (Spearman's correlation coefficient [r] = 0.805; p < 0.001) and postoperative (r = 0.901; p < 0.001) groups. ECD from CellChek-20 was higher than EM-4000 in both healthy (mean difference = 228.9 cells/mm2; p < 0.001) and postoperative (mean difference = 115.6 cells/mm2; p < 0.001) groups. The CCT values also showed a strong correlation in healthy eyes (r = 0.974; p < 0.001) and in postoperative eyes (r = 0.936; p < 0.001); however, significant inter-instrument differences were observed. HEX and CV showed significant differences and relatively weak correlations (r < 0.7) between the two devices in both healthy and postoperative groups. CONCLUSION: The ECD values between the two instruments were correlated, but that of the CellChek-20 was significantly higher than that of the EM-4000 in both healthy and postoperative eyes after pIOL surgery. Most previous studies have also shown that the Konan software overestimated the ECD compared to other products in automatic measurement mode. The possibility of measurement bias should be considered when replacing equipment used for corneal endothelial cell measurements.


Subject(s)
Endothelium, Corneal , Phakic Intraocular Lenses , Humans , Endothelium, Corneal/pathology , Female , Cell Count , Male , Adult , Retrospective Studies , Cross-Sectional Studies , Postoperative Period , Young Adult , Lens Implantation, Intraocular , Middle Aged , Myopia/surgery
15.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 49(4): 553-561, 2024 Apr 28.
Article in English, Chinese | MEDLINE | ID: mdl-39019784

ABSTRACT

OBJECTIVES: Age-related cataract is the most common type of adult cataract and a leading cause of blindness. Currently, there are few reports on the establishment of animal models for age-related cataract. During the experimental breeding of Microtus fortis (M. fortis), we first observed that M. fortis aged 12 to 15 months could naturally develop cataracts. This study aims to explore the possibility of developing them as an animal model for age-related cataract via identifing and analyzing spontaneous cataract in M. fortis. METHODS: The 12-month-old healthy M. fortis were served as a control group and 12-month-old cataractous M. fortis were served as an experimental group. The lens transparency was observed using the slit-lamp biomicroscope. Hematoxylin and eosin staining was used to detect pathological changes in the lens. Biochemical detection methods were applied to detect blood routine, blood glucose levels, the serum activities of superoxide dismutase (SOD), and glutathione peroxidase (GSH-Px) in both groups. Finally, real-time RT-PCR was used to detect the transcription levels of cataract-related genes in the lens of 2 groups. RESULTS: Compared with the control group, the lens of cataract M. fortis showed severely visible opacity, the structure of lens was destroyed seriously, and some pathological damage, such as swelling, degeneration/necrosis, calcification, hyperplasia, and fiber liquefaction were found in lens epithelial cells (LECs). The fibrous structure was disorganized and irregularly distributed with morgagnian globules (MGs) aggregated in the degenerated lens fibers. There was no statistically significant difference in blood glucose levels between the experimental and control groups (P>0.05). However, white blood cell (WBC) count (P<0.05), lymphocyte count (P<0.01), and lymphocyte ratio (P<0.05) were significantly decreased, while neutrophil percentage (P<0.05) and monocyte ratio (P<0.01) were significantly increased. The serum activities of SOD and GSH-Px (both P<0.05) were both reduced. The mRNAs of cataract-related genes, including CRYAA, CRYBA1, CRYBB3, Bsfp1, GJA3, CRYBA2, MIP, HspB1, DNase2B, and GJA8, were significantly downregultaed in the lenses of the experimental group (all P<0.05). CONCLUSIONS: There are significant differences in lens pathological changes, peroxidase levels, and cataract-related gene expression between cataract and healthy M. fortis. The developed cataract spontaneously in M. fortis is closely related to age, the cataract M. fortis might be an ideal animal model for the research of age-related cataract.


Subject(s)
Arvicolinae , Cataract , Glutathione Peroxidase , Lens, Crystalline , Superoxide Dismutase , Animals , Cataract/genetics , Cataract/pathology , Cataract/etiology , Lens, Crystalline/pathology , Glutathione Peroxidase/genetics , Glutathione Peroxidase/metabolism , Glutathione Peroxidase/blood , Superoxide Dismutase/genetics , Superoxide Dismutase/metabolism , Aging , Disease Models, Animal
16.
Int J Ophthalmol ; 17(7): 1300-1306, 2024.
Article in English | MEDLINE | ID: mdl-39026913

ABSTRACT

AIM: To determine the factors related to preoperative ocular characters that are predictive of insufficient vault (<250 µm) after implantable collamer lens (ICL V4c; STAAR Surgical) implantation. METHODS: The participants underwent ICL surgery and were divided into the low (<250 µm) and normal (250-1000 µm) vault groups based on the postoperative vault at 3mo. The preoperative biometric parameters and clinical outcomes were compared between the two groups. The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations. RESULTS: Sixteen (23 eyes) and 36 patients (63 eyes) were in the low and normal vault groups, respectively. All implantation procedures were uneventful with no cataract formation in the early postoperative period. The sulcus-to-sulcus lens rise (STSL) and iris ciliary angle (ICA) were correlated with vault at 3mo after surgery. Every 0.1 mm increase in STSL was associated with 38.9 µm decrease in the postoperative 3-month vault. A rise of 1 degree in ICA is associated with a reduction of 4 µm in vault. CONCLUSION: Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation, suggesting a need for adjustments to the ICL size in these patients. Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.

17.
Int J Ophthalmol ; 17(7): 1173-1183, 2024.
Article in English | MEDLINE | ID: mdl-39026918

ABSTRACT

In his beautiful book, Consilience: The Unity of Knowledge, the eminent biologist Edward O Wilson, advocates the need for integration and reconciliation across the sciences. He defines consilience as "literally a 'jumping together' of knowledge with a linking of facts ... to create a common groundwork of explanation". It is the premise of this paper that as much as basic biomedical research is in need of data generation using the latest available techniques- unifying available knowledge is just as critical. This involves the necessity to resolve contradictory findings, reduce silos, and acknowledge complexity. We take the cornea and the lens as case studies of our premise. Specifically, in this perspective, we discuss the conflicting and fragmented information on protein aggregation, oxidative damage, and fibrosis. These are fields of study that are integrally tied to anterior segment research. Our goal is to highlight the vital need for Wilson's consilience and unity of knowledge which in turn should lead to enhanced rigor and reproducibility, and most importantly, to greater understanding and not simply knowing.

18.
Int J Ophthalmol ; 17(7): 1205-1216, 2024.
Article in English | MEDLINE | ID: mdl-39026915

ABSTRACT

AIM: To explore the effect of silent information regulator factor 2-related enzyme 1 (SIRT1) on modulating apoptosis of human lens epithelial cells (HLECs) and alleviating lens opacification of rats through suppressing endoplasmic reticulum (ER) stress. METHODS: HLECs (SRA01/04) were treated with varying concentrations of tunicamycin (TM) for 24h, and the expression of SIRT1 and C/EBP homologous protein (CHOP) was assessed using real-time quantitative polymerase chain reaction (RT-PCR), Western blotting, and immunofluorescence. Cell morphology and proliferation was evaluated using an inverted microscope and cell counting kit-8 (CCK-8) assay, respectively. In the SRA01/04 cell apoptosis model, which underwent siRNA transfection for SIRT1 knockdown and SRT1720 treatment for its activation, the expression levels of SIRT1, CHOP, glucose regulated protein 78 (GRP78), and activating transcription factor 4 (ATF4) were examined. The potential reversal of SIRT1 knockdown effects by 4-phenyl butyric acid (4-PBA; an ER stress inhibitor) was investigated. In vivo, age-related cataract (ARC) rat models were induced by sodium selenite injection, and the protective role of SIRT1, activated by SRT1720 intraperitoneal injections, was evaluated through morphology observation, hematoxylin and eosin (H&E) staining, Western blotting, and RT-PCR. RESULTS: SIRT1 expression was downregulated in TM-induced SRA01/04 cells. Besides, in SRA01/04 cells, both cell apoptosis and CHOP expression increased with the rising doses of TM. ER stress was stimulated by TM, as evidenced by the increased GRP78 and ATF4 in the SRA01/04 cell apoptosis model. Inhibition of SIRT1 by siRNA knockdown increased ER stress activation, whereas SRT1720 treatment had opposite results. 4-PBA partly reverse the adverse effect of SIRT1 knockdown on apoptosis. In vivo, SRT1720 attenuated the lens opacification and weakened the ER stress activation in ARC rat models. CONCLUSION: SIRT1 plays a protective role against TM-induced apoptosis in HLECs and slows the progression of cataract in rats by inhibiting ER stress. These findings suggest a novel strategy for cataract treatment focused on targeting ER stress, highlighting the therapeutic potential of SIRT1 modulation in ARC development.

19.
Int J Ophthalmol ; 17(7): 1322-1330, 2024.
Article in English | MEDLINE | ID: mdl-39026921

ABSTRACT

AIM: To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port (V4c T-ICL) implantation over 1y of follow-up. METHODS: A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively, 1 and 12mo postoperatively. Vector analysis was used for astigmatism changes. Coefficient of adjustment (CAdj) was calculated for corneal coupling analysis. RESULTS: The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up (P=0.193). At the last visit, 84% of the eyes achieved a CDVA of 0.00 logMAR or better. Regarding spherical equivalent refraction (SEQ), 96% of eyes were ranges of ±1.00 D and 84% of them within ±0.50 D. Also, 94% of eyes had a remaining refractive cylinder within ±1.00 D and 78% of them within ±0.50 D. Both, SEQ and refractive cylinder, remain stable over the postoperative follow-up (P=1.000 and P=0.660, respectively). In terms of surgically induced astigmatism (SIA), no statistically significant differences were found over the follow-up (P=0.102) and under correction was found with a correction index lower than the unit at each visit. A keratometric astigmatism induced of 0.59±0.53 (vector mean: 0.26×73°) D was reached at the last visit. No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits (P=0.129 and P=0.097 at 1 and 12mo respectively). No clinical significance was found for CAdj on with-the-rule astigmatism. No postoperative complications resulting from the surgery were found. CONCLUSION: Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness, safety, and stability during 1y of follow-up. Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery. Corneal coupling analysis results in no unexpected spherical change.

20.
Int J Ophthalmol ; 17(7): 1370-1374, 2024.
Article in English | MEDLINE | ID: mdl-39026920

ABSTRACT

Among refractive errors, astigmatism is the most common optical aberration, where refraction changes in different meridians of the eye. It causes blurred vision at any distance and includes corneal, lenticular, and retinal astigmatism. Cataract surgery used to cause a progressive increase in the pre-exisiting corneal astigmatism because of creating a surgically induced astigmatism, for example, a large size surgery incision. The development of surgical techniques during last decades has made cataract surgery interchange to treat preoperative corneal astigmatism at time of surgery. Nowadays, three surgical approaches can be used. By placing a sutureless clear corneal incision on the steep meridian of the cornea, a preoperative corneal astigmatism less than 1.0 D can be corrected. Single or paired peripheral corneal relaxing incisions (PCRIs) provide 1.0-3.0 D corneal astigmatism correction. PCRIs are typically used for treating 1.0-1.5 D of regular corneal astigmatism, if more than 2.0 D, the risk of overcorrection and irregular astigmatism is increased. When toric intraocular lenses (IOLs) are unavailable in markets, PCRIs are still a reasonable option for patients with up to 3.0 D of pre-existing corneal astigmatism. Toric IOLs implantation can correct 1.0-4.5 D of corneal astigmatism. Several IOLs are approved to correct a high degree of corneal astigmatism with cylinder power up to 12.0 D. These approaches can be used alone or in combination.

SELECTION OF CITATIONS
SEARCH DETAIL
...