Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.877
Filter
1.
Med Mol Morphol ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980406

ABSTRACT

The prevalence of presbyopia and nuclear cataracts (NUC) is reported to be higher in tropical areas than that in other regions, suggesting a potential influence of high temperatures on lens health. Transient receptor potential vanilloid (TRPV) channels play a crucial role in detecting ambient temperatures across various species, with TRPV1 and TRPV4 expressed in lens epithelial cells. In this study, we investigated whether ambient temperatures affect TRPV1 and TRPV4 activity in the lens, potentially contributing to the development of presbyopia and NUC. We conducted experiments using cultured human lens epithelial cell lines under different temperature conditions. Our results revealed that the mitogen-activated protein kinase (MEK)/extracellular signal-regulated kinase (ERK) and p38 pathways, downstream molecules of TRPV1, were activated, while Src family kinase, a downstream molecule of TRPV4, was inhibited at 37.5 °C culture compared to 35.0 °C. Confocal microscope images demonstrated higher expression of TRPV1 in 3D-structured cells under high-temperature culture conditions. Additionally, in organ culture lenses, higher elasticity was observed at elevated temperatures compared to that at lower temperatures. These results suggest that high ambient temperatures may induce lens sclerosis via TRPV1 activation, potentially contributing to the development of presbyopia and NUC.

2.
Int Ophthalmol ; 44(1): 324, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980539

ABSTRACT

PURPOSE: To report the comparison of the therapeutic effects of lens capsular flap transplantation (LCT) and autologous retinal transplantation (ART) in refractory macular hole (MH) treatment. METHODS: Thirty-one patients (31 eyes) with refractory MH were retrospectively reviewed. The patients were divided into two groups based on the surgical procedures: the LCT group (13 eyes) and the ART group (18 eyes). Patients were monitored for a minimum of 6 months. Best corrected visual acuity (BCVA), hole closure rate, postoperative central foveolar thickness (CFT), and some complications (e.g. graft loss or dislocation, postoperative retinal detachment, or postoperatively elevated intraocular pressure) were the primary outcome measures. RESULTS: The mean preoperative MH diameter was 1104 ± 287 µm in the LCT group and 1066 ± 297 µm in the ART group (t = 0.353, P = 0.727). The MH was closed in 12 patients (92.3%) of the LCT group and 17 patients (94.4%) of the ART group (χ2 = 0.057, P = 0.811); the MHs of 10 patients (76.9%) in the LCT group and 11 patients (61.1%) in the ART group were completely closed (χ2 = 0.864, P = 0.353). The BCVA improved from 2.3 ± 1.0 logMAR preoperatively to 1.3 ± 0.9 logMAR postoperatively in the LCT group and 2.3 ± 0.9 logMAR preoperatively to 1.0 ± 0.6 logMAR postoperatively in the ART group (postoperative BCVA vs preoperative BCVA in the LCT group: t = 4.374, P = 0.001; postoperative BCVA vs preoperative BCVA in the ART group: t = 5.899, P = 0.000018). The visual improvement was 1.3 ± 0.9 logMAR in the ART group and 1.0 ± 0.8 logMAR in the LCT group (t = - 1.033, P = 0.310). The postoperative CFT was 139.7 ± 48.3 µm in the LCT and 199.2 ± 25.1 µm in the ART group (t = - 4.062, P = 0.001). Graft dislocation emerged in 2 patients (15.4%) in the LCT group and 1 patient (5.6%) in the ART group. CONCLUSIONS: Applications of LCT and ART may both enhance anatomical and visual outcomes in refractory MH cases. The ART group exhibited a more optimal postoperative CFT than the LCT group one.


Subject(s)
Retina , Retinal Perforations , Surgical Flaps , Tomography, Optical Coherence , Transplantation, Autologous , Visual Acuity , Vitrectomy , Humans , Male , Female , Retinal Perforations/surgery , Retinal Perforations/diagnosis , Retinal Perforations/physiopathology , Retrospective Studies , Middle Aged , Aged , Vitrectomy/methods , Retina/transplantation , Lens Capsule, Crystalline/surgery , Lens Capsule, Crystalline/transplantation , Treatment Outcome , Follow-Up Studies , Adult
3.
Clin Ophthalmol ; 18: 1933-1944, 2024.
Article in English | MEDLINE | ID: mdl-38983598

ABSTRACT

Purpose: To assess the refractive and visual outcomes of hyperopic and astigmatic eyes implanted with a monofocal, aspheric, bitoric intraocular lens (IOL) with plate haptics following cataract surgery. Methods: The study evaluated 51 eyes implanted with the AT TORBI 709M IOL (Carl Zeiss Meditec AG, Jena, Germany) during a follow-up of 12-months. Refractive error, rotational stability, monocular uncorrected distance visual acuity (UDVA), monocular corrected distance visual acuity (CDVA), and contrast sensitivity were analyzed at 1-, 6-, and 12-months post-surgery. Results: At 12 months, the cumulative CDVA was 20/25 in 94.12% of eyes and 20/32 or better in 98.04%. The UDVA was the same as, or better than, the CDVA in 88.24% of eyes. The mean logMAR UDVA and CDVA values were 0.06 ± 0.11 and 0.00 ± 0.08, respectively. In addition, 92.16% of eyes were within ±0.50 D and 98.04% were within ±1.00 D of a spherical equivalent, and 86.27% of eyes had refractive astigmatism ≤0.50D and 100% were ≤1.00D. The mean spherical equivalent was 0.21 ± 0.31D and the mean refractive cylinder 0.34 ± 0.27D. The IOL rotation was 1.18 ± 1.35 degrees and all eyes had a rotation ≤5 degrees. The log contrast sensitivity functions were good and similar for all spatial frequencies during follow-up. Conclusion: Our results demonstrate that implantation of the AT TORBI 709M IOL in hyperopic and astigmatic eyes is effective and safe. The visual and refractive outcomes were good, showing excellent rotational stability.

4.
World J Diabetes ; 15(6): 1199-1211, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38983821

ABSTRACT

The incidence of cataracts is significantly higher in diabetic individuals, particularly in younger age groups, with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics. Cataract surgery in diabetic patients poses many challenges: Poor epithelial healing, decreased corneal sensitivity, increased central corneal thickness, decreased endothelial cell count, variable topography, poor pupillary dilatation, anterior capsular phimosis, posterior capsular opacification (PCO), chances of progression of diabetic retinopathy (DR), zonular weakness, and vitreous prolapse and diabetic macular edema. Selection of an appropriate intraocular lens (IOL) is crucial for visual rehabilitation and monitoring DR. The choice of IOL in diabetic cataract patients is a challenging scenario. Square-edge IOLs are favored for their capacity to mitigate PCO, whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR. The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation, particularly in the presence of advanced retinopathy. Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications. Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes. This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.

5.
Front Ophthalmol (Lausanne) ; 4: 1310468, 2024.
Article in English | MEDLINE | ID: mdl-38984113

ABSTRACT

Purpose: Glare is a known side effect of intraocular lens (IOL) implantation, affected principally by IOL material and optics, although it is reported subjectively to decrease in impact with time. However, little objective data have been published on changes over time, how these relate to subjective reports, and whether those who will report greater glare symptoms can be predicted prior to IOL implantation. Methods: A total of 32 patients (aged 72.4 ± 8.0 years) with healthy eyes were implanted bilaterally with hydrophilic 600s (Rayner, Worthing, UK) or hydrophobic Acrysof (Alcon, Texas, USA) acrylic IOLs (n = 16 each, randomly assigned). Each patient reported their dysphotopsia symptoms subjectively using the validated forced choice photographic questionnaire for photic phenomena, and halo size resulting from a bright light in a dark environment was quantified objectively in eight orientations using the Aston Halometer. Assessment was performed binocularly pre-operatively and at 1, 2, 3, and 4 weeks after IOL implantation. Setting: The study was carried out at the National Health Service Ophthalmology Department, Queen Elizabeth Hospital, Birmingham, UK. Results: Visual acuity (average 0.37 ± 0.26 logMAR) did not correlate with subjective glare (r = 0.184, p = 0.494) or objective glare (r = 0.294, p = 0.270) pre-surgery. Objective halo size (F = 112.781, p < 0.001) decreased with cataract removal and IOL implantation and continued to decreased over the month after surgery. Subjective dysphotopsia complaints (p < 0.001) were also greater pre-surgery, but did not change thereafter (p = 0.228). In neither case was there a difference with IOL material (p > 0.05). It was not possible to predict post-surgery dysphotopsia from symptoms or a ratio of symptoms to halo size pre-surgery (p > 0.05). Conclusions: Subjective dysphotopsia and objective halos caused by cataracts are greatly reduced by implantation of IOL after cataract removal causing few perceivable symptoms. However, objective measures are able to quantify a further reduction in light scatter over the first month post-IOL implantation, suggesting that any subjective effects over this period are due to the healing process and not due to neuroadaptation.

6.
Front Ophthalmol (Lausanne) ; 4: 1387961, 2024.
Article in English | MEDLINE | ID: mdl-38984115

ABSTRACT

Connexin 50 (Cx50) mediated signaling is essential for controlling the lens growth and size. Cx50 mutations cause microphthalmia, smaller lenses, and cataracts in humans and animals. These ocular defects have never been investigated in live Cx50 mutant mice by using non-invasive imaging techniques. Here, we report a longitudinal study of the ocular defects in Cx50 knockout (Cx50KO) mice from the ages of 3 weeks to 12 months by using spectral-domain optical coherence tomography (SD-OCT). The anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD), and axial length (AL) were measured along the visual axis and adjusted with corresponding refractive indices. The SD-OCT image data confirm age-related reductions of LT and AL in live Cx50KO mice compared to age-matched wild-type (WT) controls, and the reduction values are comparable to the in vitro measurements of Cx50KO eyeballs and lenses reported previously. Moreover, reductions of ACD were observed in Cx50KO mice at all ages studied while VCD changes are statistically insignificant in comparison to the WT controls. Therefore, Cx50KO's microphthalmia with small lens is selectively associated with delayed ACD development but not the vitreous formation. This work supports the notion that lens size and/or growth is important for anterior chamber development.

7.
Front Ophthalmol (Lausanne) ; 4: 1362350, 2024.
Article in English | MEDLINE | ID: mdl-38984127

ABSTRACT

Introduction: Cataract is the leading cause of blindness among the elderly worldwide. Twin and family studies support an important role for genetic factors in cataract susceptibility with heritability estimates up to 58%. To date, 55 loci for cataract have been identified by genome-wide association studies (GWAS), however, much work remains to identify the causal genes. Here, we conducted a transcriptome-wide association study (TWAS) of cataract to prioritize causal genes and identify novel ones, and examine the impact of their expression. Methods: We performed tissue-specific and multi-tissue TWAS analyses to assess associations between imputed gene expression from 54 tissues (including 49 from the Genotype Tissue Expression (GTEx) Project v8) with cataract using FUSION software. Meta-analyzed GWAS summary statistics from 59,944 cataract cases and 478,571 controls, all of European ancestry and from two cohorts (GERA and UK Biobank) were used. We then examined the expression of the novel genes in the lens tissue using the iSyTE database. Results: Across tissue-specific and multi-tissue analyses, we identified 99 genes for which genetically predicted gene expression was associated with cataract after correcting for multiple testing. Of these 99 genes, 20 (AC007773.1, ANKH, ASIP, ATP13A2, CAPZB, CEP95, COQ6, CREB1, CROCC, DDX5, EFEMP1, EIF2S2, ESRRB, GOSR2, HERC4, INSRR, NIPSNAP2, PICALM, SENP3, and SH3YL1) did not overlap with previously reported cataract-associated loci. Tissue-specific analysis identified 202 significant gene-tissue associations for cataract, of which 166 (82.2%), representing 9 unique genes, were attributed to the previously reported 11q13.3 locus. Tissue-enrichment analysis revealed that gastrointestinal tissues represented one of the highest proportions of the Bonferroni-significant gene-tissue associations (21.3%). Moreover, this gastrointestinal tissue type was the only anatomical category significantly enriched in our results, after correcting for the number of tissue donors and imputable genes for each reference panel. Finally, most of the novel cataract genes (e.g., Capzb) were robustly expressed in iSyTE lens data. Discussion: Our results provide evidence of the utility of imputation-based TWAS approaches to characterize known GWAS risk loci and identify novel candidate genes that may increase our understanding of cataract etiology. Our findings also highlight the fact that expression of genes associated with cataract susceptibility is not necessarily restricted to lens tissue.

8.
Front Ophthalmol (Lausanne) ; 4: 1410860, 2024.
Article in English | MEDLINE | ID: mdl-38984128

ABSTRACT

Cataracts, defined as any opacity in the transparent ocular lens, remain the leading cause of blindness and visual impairment in the world; however, the etiology of this pathology is not fully understood. Studies in mice and humans have found that the EphA2 receptor and the ephrin-A5 ligand play important roles in maintaining lens homeostasis and transparency. However, due to the diversity of the family of Eph receptors and ephrin ligands and their promiscuous binding, identifying functional interacting partners remains a challenge. Previously, 12 of the 14 Ephs and 8 of 8 ephrins in mice were characterized to be expressed in the mouse lens. To further narrow down possible genes of interest in life-long lens homeostasis, we collected and separated the lens epithelium from the fiber cell mass and isolated RNA from each compartment in samples from young adult and middle-aged mice that were either wild-type, EphA2-/- (knockout), or ephrin-A5 -/- . Reverse transcription quantitative polymerase chain reaction (RT-qPCR) was implemented to compare transcript levels of 33 Eph and ephrin gene variants in each tissue compartment. Our results show that, of the Eph and ephrin variants screened, 5 of 33 showed age-related changes, and 2 of 33 showed genotype-related changes in lens epithelium. In the isolated fibers, more dynamic gene expression changes were observed, in which 12 of 33 variants showed age-related changes, and 6 of 33 showed genotype-related changes. These data allow for a more informed decision in determining mechanistic leads in Eph-ephrin-mediated signaling in the lens.

9.
Semin Ophthalmol ; : 1-5, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38984920

ABSTRACT

PURPOSE: To assess intra-operative complications and feasibility of removing crystalline lens fragments from the vitreous cavity through a limbal incision compared to a pars plana approach. DESIGN: Retrospective cohort study. SUBJECTS: 16 eyes underwent phacofragmentation via a limbal approach (Group A) and 9 eyes through a pars plana approach (Group B) at an academic center over a 10-year period. METHODS: We collected pre-operative, intra-operative, and post-operative data. We compared rates of intraoperative complications, including corneal wound burn, iris or capsular damage, retinal tears, and hemorrhage, and recorded post-operative BCVA and IOP measurements at the one-month post-operative appointment. We also compared rates of post-operative complications, including corneal edema, choroidal detachment, or retinal detachment. MAIN OUTCOME MEASURES: Primary outcomes of the study were the rates of intraoperative complications and the feasibility of crystalline lens removal with the limbal approach. We defined the latter outcome as the ability to complete lens removal without switching to the pars plana route. RESULTS: Mean BCVA for group A was 1.6, and for group B was 2.0 (p = .19). There was no significant difference between the two groups in the incidence of intraoperative complications, including corneal wound burn, iris damage, anterior capsular tear, iatrogenic retinal tear, or suprachoroidal hemorrhage (p > .99). There was no significant difference in the incidence of intra-operative vitreous hemorrhage (p = .36). Additionally, there was no significant difference in post-operative corneal edema (p = .27), choroidal detachment (p = .52), or retinal detachment (p > .99). The mean post-operative BCVA was 1.0 in group A and 1.0 in group B (p = .75). We completed all cases in group A using the limbal approach without switching to the pars plana route. CONCLUSION: Phacofragmentation through a limbal incision provides a feasible option for dropped nuclear fragment removal and is not associated with a higher risk of complications than the pars plana route.

10.
Ophthalmology ; 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38972357

ABSTRACT

PURPOSE: To investigate the myopia control efficacy of novel Lenslet-ARray-Integrated (LARI) spectacle lenses with positive (PLARI) and negative (NLARI) power lenslets worn for one year in myopic children. DESIGN: Randomized, double-masked, controlled clinical trial. PARTICIPANTS: A total of 240 children, aged 6 to 12 years, with spherical equivalent refraction (SER) between -4.00 and -1.00 diopter (D), astigmatism of 1.50 D or less, and anisometropia of 1.00 D or less. METHODS: Participants were assigned randomly in a 1:1:1 ratio to PLARI, NLARI, and a control (single-vision (SV)) groups. Cycloplegic autorefraction and axial length were measured at baseline and 6-month intervals after lens wear. MAIN OUTCOME MEASURES: Changes in SER, axial elongation (AE), and differences between groups. RESULTS: After 1-year, SER changes and AE in the PLARI and NLARI groups were significantly less than those in the SV group (SER: -0.30 ± 0.48 D, -0.21 ± 0.35 D, -0.66 ± 0.40 D; AE: 0.19 ± 0.20 mm, 0.17 ± 0.14 mm, 0.34 ± 0.18 mm, respectively) (all P < 0.001). There were no significant differences in SER changes and AE between PLARI and NLARI groups (P = 0.54 and P = 1.00, respectively). Younger age was associated with more rapid SER increase and larger AE in the SV (r = 0.40, P < 0.001 and r = -0.59, P < 0.001, respectively) and PLARI (r= 0.46, P < 0.001 and r = -0.52, P < 0.001, respectively) groups, but not in the NLARI group (r = -0.002, P = 0.98 and r = -0.08, P = 0.48, respectively). CONCLUSIONS: Compared with the SV group, both PLARI and NARI groups showed significantly slower myopia progression in terms of SER and axial elongation. Faster myopia progression, in terms of both SER and AE, was associated with younger age in the SV and PLARI groups, but not in the NLARI group.

11.
Exp Eye Res ; : 109992, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38972445

ABSTRACT

Previous studies have shown that pharmaceutical agents such as lipoic acid have the ability to soften the lens, presenting a promising avenue for treating presbyopia. One obstacle encountered in the preclinical stage of such agents is the need for precise measurements of lens elasticity in experimental models. This study aimed to evaluate the effects of 25-hydroxycholesterol, lipoic acid, and obeticholic acid on the viscoelastic properties of mouse lenses using a custom-built elastometer system. Data were acquired on lenses from C57BL/6J female mice from two age groups: young (age: 8-10 weeks) and old (age: 32-43 weeks). OD lenses were used as the control and OS lenses were treated. Control lenses were immersed in Dulbecco's Modified Eagle Medium (DMEM) and treatment lenses were immersed in a compound solution containing 25-hydroxycholesterol (5 young and 5 old), lipoic acid at 2.35 mM (5 young and 5 old), lipoic acid at 0.66 mM (5 old), or obeticholic acid (5 old) at 37ºC for 18 hours. After treatment, the mouse lenses were placed in a DMEM-filled chamber within a custom-built elastometer system that recorded the load and lens shape as the lens was compressed by 600 µm at a speed of 50 µm/s. The load was continuously recorded during compression and during stress-relaxation. The compression phase was fit with a linear function to quantify lens stiffness. The stress-relaxation phase was fit with a 3-term exponential relaxation model providing relaxation time constants (t1, t2, t3), and equilibrium load. The lens stiffness, time constants and equilibrium load were compared for the control and treated groups. Results revealed an increase in stiffness with age for the control group (young: 1.16 ± 0.11 g/mm, old: 1.29 ± 0.14 g/mm) and relaxation time constants decreased with age (young: t1 = 221.9 ± 29.0 s, t2 = 24.7 ± 3.8 s, t3 = 3.12 ± 0.87 s, old: t1 = 183.0 ± 22.0 s, t2 = 20.6 ± 2.6 s and t3 = 2.24 ± 0.43 s). Among the compounds tested, only 25-hydroxycholesterol produced statistically significant changes in the lens stiffness, relaxation time constants, and equilibrium load. In conclusion, older mouse lenses are stiffer and less viscous than young mouse lenses. Notably, no significant change in lens stiffness was observed following treatment with lipoic acid, contrary to previous findings.

12.
JPhys Photonics ; 6(3): 035021, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38975030

ABSTRACT

Lens biomechanical properties are critical for our eyes to accommodate. While it is well understood that lens mechanical properties change with age, different experimental techniques have been used over the years, with varying results on how the lens modulus changes. In this study, we developed a spatial-varying elasticity model to characterize the overall elastic modulus of the lens and establish its effect on accommodation. First, to validate the model, ex vivo porcine lenses underwent compression testing using biopsy punches of different diameters to change the percentage of nucleus within samples. Importantly, we found that, indeed, changing nucleus/cortex spatial ratio produces dramatic (∼7-fold) increase in overall sample modulus. Comparing the model with human lens spatial ratios, we demonstrate how changing spatial mechanics are more influential than peak modulus changes on overall elastic modulus. Next, in vivo clinical measurements of the spatial-varying lens modulus were used to generate a simplified mechanical-optical model of accommodation. We defined an ellipsoid lens with patient-derived modulus and geometry measurements, and a statics simulation and ray tracing analysis were performed through the deformed and undeformed lens. The resulting accommodation estimates agree with general accommodation expectations.

13.
Cureus ; 16(6): e61727, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38975537

ABSTRACT

Charles D. Kelman was a brilliant American ophthalmologist who revolutionized cataract surgery by introducing phacoemulsification to replace extracapsular cataract extraction. He used an ultrasonic probe to emulsify and aspirate the lens through a small incision (3-4 mm). Kelman's technique met initial resistance at first, but it gained global acceptance after proving its safety and effectiveness in the management of cataractous eyes, and it has been the preferred technique until now. Today, the entire surgery is performed in 5-7 minutes. This technique also helped to reduce hospitalization after the surgical removal of a cataract. Kelman is one of the greatest surgeons of the last century.

14.
Int J Retina Vitreous ; 10(1): 47, 2024 Jul 07.
Article in English | MEDLINE | ID: mdl-38972966

ABSTRACT

BACKGROUND: Dislocated IOL exchange conventionally involves manipulation within the anterior chamber which risks secondary injury to anterior chamber structures. We describe and evaluate a 4-haptic IOL rescue technique that avoids entering the anterior chamber and thus minimizes post operative inflammation, astigmatism and recovery time relative to conventional IOL explantation and replacement techniques. METHODS: Retrospective, non-randomized, interventional study of all patients undergoing 4-haptic IOL rescue performed by two independent vitreoretinal surgeons at a single UK centre over two years. SURGICAL TECHNIQUE: A limited peritomy is performed with four 25-gauge scleral ports placed to enable use of two forceps, an infusion and a chandelier. A further four 27-gauge sclerotomies are symmetrically placed on the nasal and temporal sclera at 3 mm from the limbus with a 5 mm vertical separation on either side. A pars plana vitrectomy is performed followed by chandelier illuminated, bimanual cleaning of the dislocated IOL using 27-gauge serrated forceps. Gore-tex sutures are threaded through the IOL islets within the vitreous cavity and externalized through the sclerotomies for scleral re-fixation followed by conjunctival closure. RESULTS: Seven patients underwent IOL recycling with Gore-Tex suture scleral re-fixation. All procedures were successful in repositioning the IOLs, with all patients satisfied with post-operative outcome. Mean (standard deviation) time to IOL dislocation was 13 (3) years. Median visual acuity significantly improved post-operatively from 0.85 logMAR (Interquartile Range [IQR]: 0.2-2.1) to 0.07 (0.02-0.60) logMAR (p = 0.02). No significant post-operative complications were noted apart from persistent cystoid macular oedema in one patient non-compliant with post-operative treatment. CONCLUSIONS: Transscleral refixation using Gore-Tex suture is an effective, safe and practical approach in the management of dislocated 4-piece IOLs.

15.
Clin Ophthalmol ; 18: 1921-1932, 2024.
Article in English | MEDLINE | ID: mdl-38978835

ABSTRACT

Purpose: Any new intraocular lens (IOL) on the market claims to outperform competitors. We aimed to estimate the modulation transfer function (MTF) for different defocus of a novel refractive enhanced depth of focus (EDoF) IOL and the simulated visual acuity over this range of vision. Further, we analyzed the wavefront pattern produced by this IOL to reveal the function of the IOL's optics. Methods: For the novel TECNIS® PureSee® (ZEN00V) IOL, through frequency and through focus MTF were recorded on the optical bench (ISO-2 Cornea 0.28 µm, 546 nm). MTFa and the simulated visual acuity were calculated for different defocus. Apertures of 3 mm and 4.5 mm were applied. Higher order aberrations of the IOLs' optics were recorded and analyzed. Results: PureSee® IOL demonstrated a considerable depth of focus of about 1.7 D at the spectacle plane and a continuous simulated visual acuity over this range of defocus. For the 4.5 mm aperture, near focus depth was reduced, yet far distance MTF was even better. Higher order aberrations revealed increased primary and secondary spherical aberrations. Conclusion: Optical bench results suggest that the new ZEN00V matches the clinical criteria of an EDoF IOL by an increased range of vision and is far distance dominant for an enlarged pupil. This behaviour seems to be due to subtle power changes in the central optics that produce a complex modification of wavefront.

16.
Article in English | MEDLINE | ID: mdl-38958111

ABSTRACT

INTRODUCTION: Actin has been implicated in lens opacification; however, the specific actin-related pathways involved in cataracts remain unelucidated. In this study, actin-related proteome changes and signaling pathways involved in the development of cataracts were evaluated. METHODS: The anterior capsule and phacoemulsification (phaco) cassette contents were collected during cataract surgery from 11 patients with diabetic cataract (DC), 12 patients with age-related cataract (ARC), and seven patients with post-vitrectomy cataract (PVC). Untargeted, global identification and quantification of proteins was performed through liquid chromatography-mass spectrometry with the data-independent acquisition (DIA). RESULTS: In phaco cassette samples, proteins with significantly lower expression in ARC than in DC and PVC were involved in various pathways, including actin binding, actin cytoskeleton reorganization, actin filament capping, cortical actin cytoskeleton organization, and small GTPase-mediated signal transduction pathways. In anterior capsules, proteins with significantly lower expression in ARC than in DC and PVC were involved in actin binding and actin cytoskeleton reorganization pathways. CONCLUSION: Actin cytoskeleton and actin-binding proteins are involved in lens fiber elongation and differentiation. Rho GTPases contribute to actin cytoskeletal reorganization, and their inactivation is linked to abnormal lens fiber migration. These findings link actin binding to lens fiber integrity, lens opacification, and cataracts.

17.
Patient Prefer Adherence ; 18: 1311-1321, 2024.
Article in English | MEDLINE | ID: mdl-38947871

ABSTRACT

Purpose: To explore 1) the level of shared decision-making (SDM) participation in intraocular lens (IOL) selection in cataract patients and the factors that influence this participation and 2) the relationships between preparation for decision-making (PrepDM)and the level of SDM participation and satisfaction with the decision (SWD). Provide guidance for improving SDM in ophthalmology. Patients and Methods: 176 cataract patients were asked to complete the PrepDM scale, the 9-item Shared Decision Making Questionnaire (SDM-Q-9) and the SWD instrument in IOL decision-making process. Multiple linear regression was used to analyze the influencing factors of the level of SDM. The Process program and bootstrap sampling method was used to test whether the level of participation in SDM was a mediating variable among the three. Results: The SDM-Q-9 median score was 77.78 (IQR 31.11-88.89). Patients with a history of surgery in the operative eye (P=0.022) or PrepDM <60 points (P<0.001) had lower SDM-Q-9 scores than patients with no history of surgery in the operative eye or PrepDM ≥60 points. Patients with an education level lower than primary school had lower SDM-Q-9 scores than patients with other education levels (P<0.05). The PrepDM of cataract patients was positively correlated with the level of SDM (r=0.768, P<0.001) and with the SWD (r=0.727, P<0.001), and the level of SDM was positively correlated with the SWD (r=0.856, P<0.001). The level of SDM fully mediated PrepDM and SDW, with a mediating effect value of 0.128 and a mediating effect of 86.66% of the total effect. Conclusion: The SDM of cataract patients involved in IOL selection was in the upper middle range. Education, history of surgery in the operated eye, and PrepDM were factors that influenced the level of SDM. The level of participation in SDM fully mediated the relationship between PrepDM and SWD.

18.
Eye Vis (Lond) ; 11(1): 25, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38951940

ABSTRACT

PURPOSE: To assess rotational stability and refractive outcomes of a new toric hydrophobic acrylic intraocular lens (IOL). DESIGN: Single-center, prospective, interventional clinical trial. METHODS: A total of 130 eyes of 82 patients with age-related cataract and total corneal astigmatism of greater than 1.0 diopters (D) received a hydrophobic acrylic toric IOL Clareon CNW0T3-9. Baseline measurement for rotational stability evaluation was performed at the end of surgery (EOS), with the patient still supine on the operating table, using non-movable vessels as reference landmarks. Postoperative retroillumination pictures were taken at 1 h, 1 week, 1 month and 4-6 months postoperatively. Subjective manifest refraction was assessed at the 6 months follow-up visit. RESULTS: Final results were obtained in 126 eyes of 80 patients. Mean absolute rotation from EOS to 6 months was 1.33 ± 2.00 [0.01, 19.80] degrees. Rotational stability values from EOS to 1 h, 1 h to 1 week, 1 week to 1 month and 1 month to 6 months were 0.86 ± 0.82 [0.00, 3.90], 1.06 ± 1.94 [0.00, 19.45], 0.47 ± 0.42 [0.00, 2.03] and 0.38 ± 0.40 [0.00, 2.56] degrees. Mean preoperative corneal astigmatism was 1.78 ± 0.83 [1.00, 4.76] D which changed to a mean postoperative refractive astigmatism of 0.33 ± 0.27 [0.00, 1.25] D at 6 months. CONCLUSION: The Clareon toric IOL presented very good rotational stability with a mean absolute rotation below 1.4° from EOS to 6 months. Only two IOLs rotated more than 5° with none of them requiring repositioning surgery. Refractive outcomes were satisfying with a mean residual refractive astigmatism below 0.50 D. TRIAL REGISTRATION: Registered at Clinicaltrials.gov NCT03803852 ; on May 17, 2022.

19.
Cont Lens Anterior Eye ; : 102259, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38951051

ABSTRACT

PURPOSE: Daily disposable contact lenses offer numerous benefits in terms of ocular health and wearer convenience. The purpose of this work is to update earlier surveys by describing global trends in daily disposable lens fitting between 2000 and 2023. METHOD: An annual contact lens prescribing survey was sent to eye care practitioners in up to 71 countries between 2000 and 2023, inclusive. Data relating to 265,106 daily wear soft lens fits undertaken in 20 countries returning reliable longitudinal data were analysed in respect of daily disposable lens fitting. RESULTS: Overall, daily disposable lens prescribing increased over time, from 17.1 % of daily wear soft lens fits in 2000 to 46.7 % in 2023 (p < 0.0001). There were significant differences between countries in daily disposable lens prescribing (p < 0.0001), and between the percentage of males fitted with daily disposable lenses, as a proportion of all daily wear soft lenses (37.2 %), compared to females (35.2 %) (p < 0.0001). Daily disposable lens wearers are slightly younger at fitting than reusable soft lens wearers (31.0 vs 31.2 years, respectively) (p < 0.0001), although this difference is not clinically meaningful. Analysis of 50,240 daily wear soft lenses fitted recently (2019-2023) were found to be prescribed for the following replacement frequencies: daily - 47 %; monthly - 42 %; 1-2 weekly - 9 %; and ≥3 monthly - 2 %. CONCLUSION: There has been a substantial increase in daily disposable lens fitting throughout the first 24 years of this century. The gradual nature of this increase is commensurate with the staged introduction of daily disposable lens designs and expanded parameter ranges over the survey period.

20.
Ophthalmol Ther ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951315

ABSTRACT

INTRODUCTION: A novel technique is described employing scleral grooves to facilitate sutureless scleral fixation of the Carlevale intraocular lens (CIL). We describe its use in a series of 47 patients with aphakia. METHODS: A retrospective study of all patients with aphakia who underwent CIL implantation with the new technique by a single surgeon during 1 year. The novelty of this technique consists in the creation of two partial-thickness linear sclerotomies (grooves), 180° apart, 2 mm from and parallel to the limbus. In the middle of each groove a full-thickness sclerotomy is performed to facilitate externalization of the CIL anchors. The groove allows the anchor to plug the full-thickness sclerotomy and to rest within the sclera without protrusion. Reported outcomes include pre-operative/post-operative visual acuity, post-operative spherical equivalent and surgical complications. Follow-up was a minimum of 6 months. RESULTS: Forty-eight eyes of 47 patients with aphakia with a mean age of 74 years (range 31-90 years) are included. The commonest causes of aphakia were intraocular lens (IOL) subluxation,with or without exfoliation (54.2%), complicated cataract surgery (29.2%), crystalline lens luxation (6.3%) and trauma (4.1%). All CILs inserted with the new technique stayed successfully in situ during follow-up. Median pre-operative best-corrected visual acuity (0.75 logMAR; range 0.1-2.7) significantly improved to 0.5 logMAR post-operatively (p < 0.001). Moreover, 78% and 65% of the operated cases were within 1.0 and 0.5 diopters, respectively, from intended refraction. The most common complications were transient cystoid macular oedema (8.3%) and transient intraocular pressure rise (8.3%), all of which resolved within 2 months. CONCLUSIONS: The proposed modification of sutureless scleral fixation of the CIL appears safe and effective. In our experience it is less time consuming and easier to perform than previous techniques and may therefore offer a useful future option.

SELECTION OF CITATIONS
SEARCH DETAIL
...