Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(2): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527833

ABSTRACT

ABSTRACT A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.


RESUMO Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.

2.
Rev Med Inst Mex Seguro Soc ; 60(2): 129-133, 2022 Mar 01.
Article in Spanish | MEDLINE | ID: mdl-35758892

ABSTRACT

Background: Cataract surgery with intraocular lens implant is, nowadays, the most frequent surgical procedure in all the world. Its success depends on a lot of factors, one of the most important is the calculation of the exact dioptric power of intraocular lens. Objective: To compare the calculation of dioptric power of intraocular lens with and without dilatation in patients with cataract. Material and methods: Longitudinal study, the calculation of the dioptric power of the intraocular lens was determined in patients without and with pupillary dilation. The variables were age, gender, eye to study, keratometry, axial length, anterior chamber depth and dioptric power of the intraocular lens. Descriptive statistics and Student t test were performed. Results: There were 37 patients, 23 females and 14 males. The average age was 68 + 7.87 years. Sixty-four eyes were studied, 30 were right and 34 left. Statistically, there was only significant difference in K2 of the ocular biometry between patients without and with pupillary dilation when obtaining a value of p < 0.05. Conclusion: There are no changes in the calculation of the dioptric power of the Intraocular lens without and with pupillary dilation.


Introducción: la cirugía de catarata con implante de un lente intraocular es, hoy en día, el procedimiento quirúrgico más frecuente en todo el mundo. Su éxito depende de muchos factores, uno de los más importantes es el cálculo exacto del poder dióptrico del lente intraocular. Objetivo: comparar el cálculo del poder dióptrico del lente intraocular en los pacientes sin y con dilatación pupilar. Material y métodos: estudio longitudinal, en el que se determinó el cálculo del poder dióptrico del lente intraocular en pacientes con y sin dilatación pupilar. Las variables de estudio fueron: edad, género, ojo a estudiar, queratometría, longitud axial, profundidad de cámara anterior y poder dióptrico del lente intraocular. Se realizó estadística descriptiva y t de Student. Resultados: se estudiaron 37 pacientes, 23 mujeres y 14 hombres. La edad promedio fue de 68 ± 7.87 años. Se estudiaron 64 ojos, 30 fueron derechos y 34 izquierdos. Estadísticamente solo hubo diferencia significativa en K2 de la biometría ocular entre pacientes sin y con dilatación pupilar al obtenerse un valor de p ≤ 0.05. Conclusión: no existen cambios en el cálculo del poder dióptrico del LIO sin y con dilatación pupilar.


Subject(s)
Cataract , Lenses, Intraocular , Aged , Biometry/methods , Cataract/etiology , Dilatation , Female , Humans , Longitudinal Studies , Male , Middle Aged
3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;85(3): 249-254, May-June 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1383808

ABSTRACT

ABSTRACT Purpose: Creating models, in pediatric cataracts, to estimate kerotometry and axial length values at future ages, based on kerotometry and axial length measured at surgery, to estimate the intraocular lens power for emmetropia in future ages. Methods: Eyes with bilateral cataract and kerotometry and axial length measured at surgery and at least one postoperative examination with kerotometry and axial length measurements, were considered for this study. The models to estimate future kerotometry and axial length values were created considering (1) kerotometry and axial length measured at surgery, (2) the average slope of kerotometry and axial length logarithmic regression created for every single eye and (3) age at surgery. The intraocular lens for future ages can be estimated using these values in third generation formulas. The estimation errors for kerotometry, axial length and intraocular lens were also calculated. Results: A total of 57 eyes from 29 patients met the inclusion criteria. The average age at the surgery and follow-up was 36.96 ± 32.04 months and 2.39 ± 1.46 years, respectively. The average slope of logarithmic regression created for every single eye were -3.286 for kerotometry and +3.189 for axial length. The average absolute estimation errors for kerotometry and axial length were respectively: 0.61 ± 0.54 D and 0.49 ± 0.55 mm, and for intraocular lens using SRK-T, Hoffer-Q and Holladay I formulas were: 2 . 04 ± 1 . 73 D , 2 . 49 ± 2 . 10 D and 2 . 26 ± 1 . 87 D, respectively. Conclusions: The presented models could be used to estimate the intraocular lens power for emmetropia at future ages to guide the choice of the intraocular lens power to be implanted in pediatric cataract.


RESUMO Objetivo: Criar modelos, em catarata pediátrica, para estimar valores futuros de ceratometria e comprimento axial, com base na ceratometria e no comprimento axial medidos na cirurgia, para previsão do poder da lente intraocular para emetropia em idades futuras. Métodos: Olhos com catarata bilateral, ceratometria e comprimento axial medidos na cirurgia e pelo menos um exame pós-operatório com medidas de ceratometria e comprimento axial foram considerados para este estudo. Os modelos para estimar futuras ceratometrias e comprimentos axiais foram criados considerando (1) ceratometria e comprimento axial medidos na cirurgia, (2) a inclinação média da regressão logarítmica da ceratometria e comprimento axial criada para cada olho e (3) a idade na cirurgia. A lente intraocular para emetropia em idades futuras pode ser estimada usando esses valores em fórmulas de terceira geração. Os erros de estimativa da ceratometria, comprimento axial e poder da lente intraocular, usando os modelos, também foram calculados. Resultados: 57 olhos de 29 pacientes preencheram os critérios de inclusão. A idade média na cirurgia e acompanhamento foram de 36,96 ± 32,04 meses e 2,39 ± 1,46 anos, respectivamente. A inclinação média da regressão logarítmica criada para cada olho foi de -3.286 para ceratometria e + 3.189 para o comprimento axial. Os erros médios de estimativa absoluta para ceratometria e comprimento axial foram respectivamente: 0,61 ± 0,54 D e 0,49 ± 0,55 mm, e para o poder da lente intraocular usando as fórmulas SRK-T, Hoffer-Q e Holladay I foram: 2,04 ± 1,73 D, 2,49 ± 2,10 D e 2,26 ± 1,87 D, respectivamente. Conclusões: Os modelos apresentados podem ser utilizados para estimar o poder da lente intraocular que levaria a emetropia em idades futuras e orientar a escolha do poder da lente intraocular a ser implantada na catarata pediátrica.

4.
Rev. Fac. Med. (Bogotá) ; 69(2): e207, Apr.-June 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1287989

ABSTRACT

Abstract Introduction: Intraocular lens (IOL) power calculation, based on ocular biometry, is a determinant for the success of cataract surgery. Objectives: To characterize the ocular biometric parameters of Colombian patients over 40 years of age who are candidates for cataract surgery and to determine the prevalence of the 9 clinical conditions proposed by Holladay according to the interaction between axial length (AL) and anterior chamber depth (ACD). Materials and methods: Analytical cross-sectional study. The ocular biometry results of 781 patients (831 eyes) who were going to be taken to cataract surgery between January 2014 and January 2015 in Medellín, Colombia, were reviewed. After applying exclusion criteria, 716 eyes were included for analysis. Data on age, sex, AL, keratometry (flat keratometry (K1) and steep keratometry (K2)), ACD and white-to-white distance were collected. Results are presented using descriptive statistics. Results: Most eyes were from women (62.3%). The mean values of AL, K1 and ACD were 23.37±1.51mm, 43.52±2.06 and 3.03mm±0.41, respectively. Mean AL in men was 23.62±1.37mm, and in women, 23.21±1.67mm. The highest mean AL was observed in patients <50 years old (23.84±2.41) and the lowest in patients ≥80 years old (22.96±1.03 mm). Regarding eye size according to their AL, 90.5% were normal, 4.89% long, and 4.61% short. Conclusions: 85% of the participants had normal biometric parameters. For the remaining 15%, it is necessary to take some precautions when calculating IOL power, such as using fourth-generation formulas like Holladay 2 in long eyes, because the same refractive behavior will not be obtained using traditional prediction formulas in these patients. Furthermore, according to the Holladay classification, excluding normal eyes, the most frequent eyes were those with myopia and axial hyperopia.


Resumen Introducción. El cálculo del poder del lente intraocular (LIO), basado en la biometría ocular, es un factor determinante del éxito en la cirugía de catarata. Objetivos. Caracterizar los parámetros biométricos oculares de pacientes colombianos mayores de 40 años candidatos a cirugía de catarata y determinar la prevalencia de las 9 condiciones clínicas propuestas por Holladay según la interacción entre longitud axial (LA) y profundidad de la cámara anterior (ACD). Materiales y métodos. Estudio transversal analítico. Se revisaron los resultados de biometría ocular de 781 pacientes (831 ojos) que iban a ser sometidos a cirugía de cataratas entre enero de 2014 y enero de 2015 en Medellín, Colombia. Luego de aplicar los criterios de exclusión, se incluyeron 716 ojos para análisis. Se recolectaron datos sobre edad, sexo, LA, queratometría (queratometría más plana (K1), queratometría más curva (K2)), ACD y distancia blanco-blanco. Los resultados se presentan mediante estadística descriptiva. Resultados. La mayoría de ojos eran de mujeres (62.3%). Las medias de LA, K1 y ACD fueron 23.37±1.51mm, 43.52±2.06 y 3.03±0.41mm, respectivamente. La media de LA en hombres fue 23.62±1.37mm, y en mujeres, 23.21±1.67mm. La media más alta de LA se observó en pacientes <50 años (23.84±2.41mm) y la más baja en aquellos ≥80 años (22.96±1.03mm). Respecto al tamaño de los ojos según su LA, 90.5% fueron normales; 4.89%, largos, y 4.61%, cortos. Conclusiones. 85% de los participantes tuvo parámetros biométricos normales. Para el 15% restante es necesario tomar precauciones al calcular el poder del LIO, tales como el uso de fórmulas de cuarta generación como la Holladay 2 en ojos largos, pues en estos pacientes no se obtendrá el mismo comportamiento refractivo con las fórmulas de predicción tradicionales. Además, según la clasificación de Holladay, excluyendo a los ojos normales, los ojos más frecuentes fueron aquellos con miopía e hipermetropía axial.

5.
Rev. bras. oftalmol ; 80(5): e0034, 2021. tab, graf
Article in English | LILACS | ID: biblio-1341156

ABSTRACT

ABSTRACT Objective To compare the performance of Sanders-Retzlaff-Kraft/Theoretical, Hoffer Q, Barrett Universal II, Kane, and Hill-radial basis function formulas to calculate intraocular lens power in eyes with normal axial length, in terms of predicting target refraction by using partial coherence interferometry technology. Methods Phacoemulsification and intraocular lens implantation were performed in 135 eyes of 135 patients with an axial length between 22 and 24.5 mm. Axial length, keratometry, and anterior chamber depth were measured by intraocular lens Master 500. Sanders-Retzlaff-Kraft/Theoretical, Hoffer Q, Barrett Universal II, Kane, and Hill-radial basis function formulas were used for intraocular lens power calculations. The difference between the expected postoperative refraction and the mean absolute prediction error was calculated for each eye. Statistical significance was evaluated at the level of p<0.05. Results The study included 135 subjects. The mean axial length, anterior chamber depth, keratometry, and intraocular lens power were 23.2±1.2 (22 to 24.5) mm, 3.2±0.4 (2.4 to 4.4) mm, 43.5±1.5 (40.8 to 46.2) diopter, 21.5±1.8 (18.5 to 25.5) diopter, respectively. The mean absolute prediction error for Sanders-Retzlaff-Kraft/Theoretical, Hoffer Q, Barrett Universal II, Kane, and Hill-radial basis function was 0.306±0.291, 0.312±0.257, 0.314±0.268, 0.299±0.206 and 0.308±0.280, respectively (p>0.05). Conclusion The study showed the third-generation (Sanders-Retzlaff-Kraft/Theoretical and Hoffer Q), fourth-generation (Barrett Universal II) and new-generation (Kane and Hill-radial basis function) intraocular lens power calculation formulas had similar performances regarding calculation of intraocular lens power to predict target refraction after phacoemulsification in eyes with normal axial length.


RESUMO Objetivo Comparar o desempenho das fórmulas Sanders-Retzlaff-Kraft/Teórica, Hoffer Q, Barrett Universal II, Kane, e Hill-radial basis function (RBF) para cálculo de poder dióptrico das lentes intraoculares, em olhos com comprimento axial normal, em termos de predição da refração alvo, utilizando a tecnologia de interferometria de coerência parcial. Métodos Facoemulsificação e implante de lentes intraoculares foram realizados em 135 olhos de 135 pacientes com comprimento axial entre 22 e 24.5 mm. Comprimento axial, ceratometria, e profundidade da câmara anterior foram medidos por lente intraocular Master 500. As fórmulas Sanders-Retzlaff-Kraft/Teórica, Hoffer Q, Barrett Universal II, Kane, e Hill-radial basis function foram empregadas para cálculo de poder dióptrico das lentes intraoculares. A diferença entre a refração esperada no pós-operatório e a média dos erros absolutos preditivos foi calculada para cada olho. Os valores de p<0,05 foram considerados estatisticamente significativos. Resultados O estudo incluiu 135 sujeitos. As médias de comprimento axial, profundidade da câmara anterior, ceratometria, e poder dióptrico das lentes intraoculares foram 23,2±1,2 (22 a 24,5) mm, 3,2±0,4 (2,4 a 4,4) mm, 43,5±1,5 (40,8 a 46,2) dioptria, 21,5±1,8 (18,5 a 25,5) dioptria, respectivamente. A média de erro absoluto preditivo para as fórmulas Sanders-Retzlaff-Kraft/Teórica, Hoffer Q, Barrett Universal II, Kane, e Hill-radial basis function foi 0,306±0,291, 0,312±0,257, 0,314±0,268, 0,299±0,206 e 0,308±0,280, respectivamente (p>0,05). Conclusão O estudo mostrou que as fórmulas de terceira geração (Sanders-Retzlaff-Kraft/Teórica e Hoffer Q), de quarta geração (Barrett Universal II) e as da nova geração (Kane e Hill-radial basis function) para cálculo de poder dióptrico das lentes intraoculares, têm desempenhos semelhantes para cálculo do poder dióptrico das lentes intraoculares, para predizer a refração alvo após facoemulsificação em olhos com comprimento axial normal.


Subject(s)
Humans , Biometry/methods , Phacoemulsification , Lens Implantation, Intraocular , Lenses, Intraocular , Refraction, Ocular/physiology , Cross-Sectional Studies , Axial Length, Eye , Observational Study
6.
Rev. bras. oftalmol ; 79(6): 386-390, nov.-dez. 2020. tab
Article in English | LILACS | ID: biblio-1156162

ABSTRACT

Abstract Purpose: To evaluate six different premium IOLs retrospectively in respect to both subjective and objective refraction after cataract operation. Methods: Five hundreds and seventy eyes of 285 patients with bilateral cataract who had undergone phacoemulsification and IOL implantation operation between February 2017 and September 2018 were enrolled in this study. The mean age of the patients was 57.78 ± 7.49 (41-71) years. Out of 285 patients 137 were male (48.07%) and 148 were female (51.93%). TheIOLsusedare: RayOne Trifocal (Rayner, Worthing, UK), Lucidis (Swiss Advanced Vision, Neuchâtel, Switzerland), PanOptix (Alcon, Fort Worth, USA), LentisMplus (Oculentis, Berlin, Germany), TecnisSymfony (Abbott, Illinois, USA) and Acriva Trinova (VSY Biotechnology, Istanbul, Turkey). Results: There were no significant differences among the groups regarding age, sex, axial length, the mean preoperative and postoperative uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), the mean preoperative spherical equivalent (SE) and the mean postoperative SE (subjective measurement) (P> .05). The postoperative refractions measured with autorefractometer were more myopic than subjective refractions in all patients except the patients who had PanOptix IOL. In postoperative twelfth month, the mean UCVA arrived 0.00 logMAR in 405 eyes (78.48%) , however, the mean autorefractometric measurement was -1.28 ± 1.02 (0.00_-2.75) D. Conclusion: The autorefractometer measurements of all patients who had premium IOLs except PanOptix IOL were not coherent with their visual acuities postoperatively. The ophthalmologists and/or optometrists should be careful while examining these types of patients.


Resumo Objetivo: Avaliar retrospectivamente seis diferentes LIOs premium em relação à refração subjetiva e objetiva após operação de catarata. Métodos: Quinhentos e setenta (570) olhos de 285 pacientes com catarata bilateral submetidos a facoemulsificação e operação de implantação de LIO entre fevereiro de 2017 e setembro de 2018 foram incluídos neste estudo. A média de idade dos pacientes foi de 57,78 ± 7,49 (41-71) anos. Dos 285 pacientes, 137 eram do sexo masculino (48,07%) e 148, do sexo feminino (51,93%). As seguintes IOLs foram utilizadas: RayOne Trifocal (Rayner, Worthing, Reino Unido), Lucidis (Swiss Advanced Vision, Neuchâtel, Suíça), PanOptix (Alcon, Fort Worth, EUA), LentisMplus (Oculentis, Berlim, Alemanha), TecnisSymfony (Abbott, Illinois, EUA) e Acriva Trinova (VSY Biotechnology, Istambul, Turquia). Resultados: Não houve diferenças significativas entre os grupos em relação à idade, sexo, comprimento axial, média da acuidade visual não corrigida pré e pós-operatória (AVNC), melhor acuidade visual corrigida (MAVC), equivalente esférico pré-operatório médio (EE) e EE pós-operatório médio (medição subjetiva) (P > 0,05). As refrações pós-operatórias medidas com autorefratômetro foram mais míopes do que as refrações subjetivas em todos os pacientes, exceto naqueles que usavam LIO PanOptix. No décimo segundo mês pós-operatório, a AVNC média chegou a 0,00 logMAR em 405 olhos (78,48%); no entanto, a medição autorefractométrica média foi de -1,28 ± 1,02 (0,00_-2,75) D. Conclusão: As medições autorefractométricas de todos os pacientes que usavam LIOs premium, exceto LIO PanOptix, não foram coerentes com suas acuidades visuais no pós-operatório. Oftalmologistas e/ou optometristas devem ter cuidado ao examinar pacientes com esses perfis.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Refraction, Ocular , Visual Acuity , Phacoemulsification/methods , Lenses, Intraocular , Retrospective Studies
7.
Arq. bras. oftalmol ; Arq. bras. oftalmol;83(6): 547-551, Nov.-Dec. 2020. graf
Article in English | LILACS | ID: biblio-1153077

ABSTRACT

ABSTRACT This article reports a combined technique of sutureless intrascleral fixated intraocular lens implantation and Descemet membrane endothelial keratoplasty in a patient with anterior pseudophakic bullous keratopathy. Two scleral tunnels were created, corneal incisions were made, and a foldable intraocular lens was cut and removed from the anterior chamber. After performing anterior vitrectomy, a 3-piece foldable intraocular lens was implanted into the anterior chamber. One of the intraocular lens haptics was grasped with a forceps and pulled out from the scleral tunnel. Then, the end of the haptic was cauterized. Similar maneuvers were applied for the other haptic. Next, an 8-mm-diameter donor tissue was prepared, and the recipient endothelial tissue was peeled and removed from the center of the recipient cornea. The prepared donor tissue was injected into the anterior chamber. After proper opening and placement of the donor tissue, an air bubble was injected below the tissue. There were no postoperative complications during the 1-month follow-up.


RESUMO Relato de uma técnica que combina o implante de uma lente intraocular com fixação intraescleral sem sutura e uma ceratoplastia endotelial da membrana de Descemet em paciente com ceratopatia bolhosa pseudofácica anterior. Foram criados dois túneis esclerais. Foram feitas incisões na córnea e a lente intraocular dobrável foi cortada e removida da câmara anterior. Foi então efetuada uma vitrectomia anterior e uma lente intraocular dobrável de 3 peças foi implantada na câmara anterior. Um dos hápticos da lente intraocular foi pinçado com um fórceps e puxado para fora do túnel escleral. A extremidade do háptico foi cauterizada. Manobras semelhantes foram feitas no outro háptico. Foi preparado um tecido de doador com 8 mm de diâmetro e o tecido endotelial da área receptora foi removido do centro da córnea. O tecido preparado do doador foi injetado na câmara anterior. Após abertura e posicionamento adequados do tecido do doador, foi injetada uma bolha de ar abaixo do tecido. Não foi observada nenhuma complicação pós-operatória durante um mês de acompanhamento.


Subject(s)
Humans , Female , Aged , Corneal Transplantation , Lenses, Intraocular , Sclera/surgery , Surgical Instruments , Lens Implantation, Intraocular , Descemet Membrane
8.
Rev. bras. oftalmol ; 79(4): 242-247, July-Aug. 2020. tab
Article in Portuguese | LILACS | ID: biblio-1137968

ABSTRACT

Resumo Objetivo: Analisar a qualidade de vida dos pacientes antes e após cirurgia de remoção da catarata associada ao implante de lente intraocular (LIO). Metodos: Este é um estudo observacional, prospectivo, de série de casos. Os dados foram coletados em um serviço privado de oftalmologia em Aracaju - SE, de agosto de 2018 a julho de 2019. A avaliação da qualidade de vida de pacientes antes e após 4 meses da cirurgia de catarata, pela técnica de facoemulsificação associada ao implante de LIO, foi realizada aplicando a versão brasileira validada do Questionário de Função Visual de 25 itens do National Eye Institute (NEI-VFQ-25) e realização do teste de acuidade visual com a tabela de Snellen. Resultados: O grupo final foi constituído por 41 pacientes, com média de idade de 72 anos (DP: 9,01), sendo 14 do sexo masculino e 27 do feminino. Além disso, dos 41 pacientes, 37 foram submetidos à facectomia em ambos os olhos, 03 apenas no olho direito e 01 apenas no olho esquerdo. Diante da coleta e da análise dos dados, notou-se melhora na qualidade de vida dos pacientes submetidos ao procedimento cirúrgico proposto. Houve um aumento estatisticamente significativo (p<0,001) na acuidade visual binocular, na acuidade visual monocular e nas pontuações de 11 dos 12 subdomínios do NEI-VFQ-25. Não foi observada significância estatística no subdomínio "Dor ocular" (p=0,934). Conclusão: Houve melhora significativa na qualidade de vida dos pacientes submetidos à cirurgia de catarata com implante de LIO.


Abstract Objective: To analyze patients' quality of life before and after cataract removal surgery associated with intraocular lens (IOL) implantation. Methods: This is an observational, prospective, case series study. Data were collected at a private ophthalmology service in Aracaju - SE, from August 2018 to July 2019. The quality of life assessment of patients before and after 4 months of cataract surgery, using the phacoemulsification technique associated with IOL implantation, was performed by applying the validated Brazilian version of the 25-item Visual Function Questionnaire from the National Eye Institute (NEI-VFQ-25) and performing the visual acuity test with the Snellen chart. Results: The final group consisted of 41 patients, with a mean age of 72 years (SD: 9.01), of which 14 were male and 27 female. In addition, out of 41 patients, 37 underwent facectomy in both eyes, 03 only in the right eye and 01 only in the left eye. Given the collection and thorough analysis of the data, the improvement in the quality of life of patients submitted to cataract surgery with intraocular lens implantation was noticed. There was a statistically significant increase (p<0.001) in binocular visual acuity, monocular visual acuity and scores in 11 of the 12 subdomains of the NEI-VFQ-25. No statistical significance was observed in the subdomain "Eye Pain" (p=0.934). Conclusion: There was a significant improvement in the quality of life of patients who underwent cataract surgery with intraocular lens implantation.


Subject(s)
Humans , Male , Female , Aged , Quality of Life , Cataract Extraction/methods , Visual Acuity , Phacoemulsification/methods , Lens Implantation, Intraocular/methods , Prospective Studies , Surveys and Questionnaires , Observational Study
9.
Arq. bras. oftalmol ; Arq. bras. oftalmol;83(4): 329-331, July-Aug. 2020. graf
Article in English | LILACS | ID: biblio-1131599

ABSTRACT

ABSTRACT Despite the recent developments in modern cataract surgery and the application of a vast array of new devices and machines, late in-the-bag intraocular lens dislocation remains a devastating, albeit rare, complication. Various nonsurgical and surgical techniques have been used to manage this complication. We report a case of spontaneous repositioning in the left eye of an anteriorly subluxated in-the-bag intraocular lens. The spontaneous repositioning may have been caused by antagonistic effects related to the topical administration of brimonidine and prednisolone. The dislocation was treated without aggressive manipulation or surgical intervention.


RESUMO Apesar dos recentes avanços na cirurgia moderna de catarata e da aplicação de uma ampla gama de novos dispositivos, o deslocamento tardio de uma lente intraocular dentro do saco capsular continua a ser uma complicação devastadora, ainda que rara. Várias técnicas cirúrgicas e não cirúrgicas têm sido usadas para tratar esta complicação. Este é o relato de um caso de reposicionamento espontâneo de uma lente intraocular sub-luxada anteriormente dentro do saco capsular do olho esquerdo. Este reposicionamento pode ter sido causado pelos efeitos opostos da aplicação tópica simultânea de brimonidina e prednisolona. O deslocamento foi tratado sem manipulação agressiva ou intervenção cirúrgica.


Subject(s)
Humans , Drug Repositioning , Lenses, Intraocular , Postoperative Complications , Visual Acuity , Lens Subluxation , Retrospective Studies
10.
Arq. bras. oftalmol ; Arq. bras. oftalmol;83(4): 289-293, July-Aug. 2020. tab, graf
Article in English | LILACS | ID: biblio-1131608

ABSTRACT

ABSTRACT Purpose: Pharmacological pupillary dilation is performed in comprehensive ophthalmological examinations and before biometric measurements. So far, there is no consensus regarding its impact on biometric measurements. This study's aim was to investigate the effects of pharmacological pupillary dilation on ocular biometric measurements in healthy children. Methods: This was a prospective, observational, non-randomized study of children (4-18 years of age) who were admitted for routine ophthalmological examination. Biometric measurements were performed, using a non-contact optical biometry device, both before and after pharmacological pupillary dilation with cyclopentolate hydrochloride. Intraocular lens power calculations were performed using Hill-RBF, Barrett, Olsen, Sanders-Retzlaff-Kraff/Theoretical, Holladay, and Hoffer Q formulas. Descriptive statistical analyses were also performed. The Wilcoxon signed-rank test was used to compare measurements before and after pharmacological pupillary dilation. Relationships between variables were analyzed using the Spearman-Brown rank correlation coefficient. Results: The study included 116 eyes of 58 children (mean age, 8.4 ± 0.32 years; 34 girls). Significant changes were observed after pupillary dilation, compared with before pupillary dilation, in terms of anterior chamber depth, aqueous depth, and central corneal and lens thicknesses. No significant change was observed in axial length. Intraocular lens power calculations revealed no significant changes after pupillary dilation in most formulas except for the Olsen formula. The intraocular lens power was significantly inversely correlated with axial length and anterior chamber depth. Conclusions: Pharmacological pupillary dilation in children appeared to have no impact on axial length and intraocular lens power, but caused a significant increase in anterior chamber depth. The difference in anterior chamber depth measurements before and after pupillary dilation could be related to the optical biometry device model used. These outcomes should be considered in intraocular lens power calculations performed using anterior chamber depth parameters.


RESUMO Objetivo: A dilatação pupilar farmacológica é realizada em exames oftalmológicos abrangentes e antes das medições biométricas. Até o momento, não há consenso sobre seu impacto nas medições biométricas. O objetivo deste estudo foi investigar os efeitos da dilatação pupilar nas medidas biométricas oculares em crianças saudáveis. Métodos: Estudo prospectivo, observacional e não randomizado de crianças (4-18 anos) que foram admitidas para exame oftalmológico de rotina. As medidas biométricas foram realizadas usando um dispositivo de biometria óptica sem contato, antes e após a dilatação pupilar farmacológica com cloridrato de ciclopentolato. Os cálculos de potência das lentes intraoculares foram realizados utilizando as fórmulas de Hill-RBF, Barrett, Olsen, Sanders-Retzlaff-Kraff/ Teórica, Holladay e Hoffer Q. Análises estatísticas descritivas também foram realizadas. O teste dos postos sinalizados de Wilcoxon foi usado para comparar as medidas antes e após a dilatação pupilar farmacológica. As relações entre as variáveis foram analisadas pelo coeficiente de correlação de Spearman-Brown. Resultados: O estudo incluiu 116 olhos de 58 crianças (idade média de 8,4 ± 0,32 anos; 34 meninas). Alterações significativas foram observadas após a dilatação pupilar, em termos de profundidade da câmara anterior, profundidade do humor aquoso e espessura central da córnea e do cristalino. Nenhuma mudança significativa ocorreu no comprimento axial. Os cálculos de potência da lente intraocular não revelaram alterações significativas após a dilatação pupilar na maioria das fórmulas, com exceção da fórmula Olsen. O poder da lente intraocular foi significativamente inversa correlacionada com o comprimento axial e a profundidade da câmara anterior. Conclusões: A dilatação pupilar farmacológica em crianças parece não ter impacto no comprimento axial e no poder da lente intraocular, mas causou um aumento significativo na profundidade da câmara anterior. A diferença nas medidas da profundidade da câmara anterior antes e após a dilatação pupilar pode estar relacionada ao modelo do dispositivo de biometria óptica utilizado. Tais resultados devem ser considerados nos cálculos de potência da lente intraocular realizados usando parâmetros de profundidade da câmara anterior.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Biometry , Dilatation , Axial Length, Eye/diagnostic imaging , Anterior Chamber/anatomy & histology , Anterior Chamber/diagnostic imaging , Refraction, Ocular , Prospective Studies , Optics and Photonics , Lenses, Intraocular
11.
Arq. bras. oftalmol ; Arq. bras. oftalmol;83(2): 141-145, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088976

ABSTRACT

ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118 eyes treated with phacoemulsification and multifocal intraocular lens implantation. Only the eyes that achieved emmetropia in the dynamic refraction performed on postoperative day 30 were included. Haigis' formula was used in each case to calculate the intraocular lens power, and the intraocular lens with the target refraction closest to emmetropia was implanted. Four lens calculation scenarios were tested by combining keratometry and anterior chamber depth measurements obtained using the two devices. Results: IOLMaster 500 and Pentacam HR differed with regard to mean keratometry (D 0.07 ± 0.03 D; p=0.0065) and anterior chamber depth (D 0.08 ± 0.01 mm; p<0.001). In the analysis of covariance, the following differences were obtained using the Haigis' formula when confronted with the biometric values obtained by inserting keratometry and anterior chamber depth values, respectively: Penta/IOL x IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/Penta × IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/IOL × IOL/IOL (0.11 ± 0.03; p=0.001); Penta/Penta × IOL/IOL (0.11 ± 0.03; p=0.002); IOL/IOL × IOL/Penta (0.02 ± 0.03; p=0.865); and Penta/IOL × Penta/Penta (0.002 ± 0.03; p=0.99). The difference was smaller when measuring the anterior chamber depth using the IOLMaster 500, regardless of which device was used to measure keratometry. Conclusions: Pentacam HR significantly differed from IOLMaster 500 when calculating keratometry. As regards the anterior chamber depth, the two devices were equally accurate.


RESUMO Objetivo: Comparar a previsibilidade refrativa pós-operatória do IOLMaster 500 e Pentacam HR com base nos valores de ceratometria e profundidade de câmara anterior nos olhos com indicação de implante de lentes intraoculares multifocais. Métodos: Estudo retrospectivo realizado em 118 olhos tratados com facoemulsificação e implante de lentes intraoculares multifocal. Apenas os olhos que atingiram a emetropia na refração dinâmica no 30º dia pós-operatório foram incluídos. A fórmula de Haigis foi usada em cada caso para calcular o poder das lentes intraoculares, e a lente intraocular com a refração alvo mais próxima da emetropia foi implantada. Cenários de cálculo de quatro lentes foram testados pela combinação de medidas de ceratometria e profundidade de câmara anterior obtidas usando os dois dispositivos. Resultados: IOLMaster 500 e Pentacam HR diferiram quanto à média de ceratometria (D 0,07 ± 0,03 D; p=0,0065) e profundidade de câmara anterior (D 0,08 ± 0,01 mm; p<0,001). Na análise da covariância, as seguintes diferenças foram obtidas usando a fórmula de Haigis quando confrontadas com os valores biométricos obtidos pela inserção dos valores de ceratometria e profundidade de câmara anterior, respectivamente: Penta/IOL x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/Penta x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/IOL x IOL/IOL (0,11 ± 0,03; p=0,001); Penta/Penta x IOL/IOL (0,11 ± 0,03; p=0,002); IOL/IOL x IOL/Penta (0,02 ± 0,03; p=0,865); Penta/IOL x Penta/Penta (0,002 ± 0,03; p=0,99). A diferença foi menor ao medir a profundidade da câmara anterior usando o IOLMaster 500, independentemente de qual dispositivo foi usado para medir a ceratometria. Conclusões: O Pentacam HR diferiu significativamente do IOLMaster 500 no cálculo de ceratometria. Quanto à profundidade da câmara anterior, os dois dispositivos foram igualmente precisos.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Phacoemulsification/methods , Cornea/pathology , Corneal Topography/instrumentation , Lens Implantation, Intraocular/methods , Multifocal Intraocular Lenses , Anterior Chamber/pathology , Postoperative Period , Reference Values , Refraction, Ocular/physiology , Time Factors , Visual Acuity/physiology , Predictive Value of Tests , Retrospective Studies , Biometry , Treatment Outcome , Cornea/diagnostic imaging , Interferometry/instrumentation , Interferometry/methods , Anterior Chamber/diagnostic imaging
12.
Rev. bras. oftalmol ; 79(1): 6-11, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1092657

ABSTRACT

Abstract Purpose: To assess long, intermediate and near uncorrected visual acuity after a tetrafocal diffractive intraocular lens implantation, presence of dystopic phenomenon and patient satisfaction after surgery. Methods: Retrospective, observational study performed in Puerta de Hierro Specialties Hospital, in Jalisco, México. That included 100 eyes after phacoemulsification surgery by femtosecond assistance, followed by tetrafocal diffractive intraocular lens implantation due to cataract. Long, intermediate and near visual acuity without correction was measured, and presence or absence of dystopic phenomenon, plus patient satisfaction after surgery. Results: A total of 100 eyes in 50 patients who underwent cataract surgery with phacoemulsification by femtosecond assistance were evaluated. 100% underwent bilateral phacoemulsification. Long, intermediate, and near visual acuity after three months was in the most patients 20/20 (46%), 20/15 (44%) and Jaeger 1 (48%) respectively. The percentage or patients who refers halos was 7%; and other associated symptoms in 18%, being astenopia the most prevalent. The removal of the lens was not required in any case. Conclusion: Tetrafocal diffractive intraocular lenses provides excellent intermediate vision (at 60 centimeters) and satisfactory near (30 centimeters) and long (6 meters) visual acuity.


Resumo Objetivo: Avaliar a acuidade visual de longe, intermediária e de perto após o implante de lente intra-ocular difrativa tetrafocal, presença de fenômenos distópicos e satisfação do paciente após a cirurgia. Métodos: Estudo retrospectivo, observacional, realizado em Puerta de Hierro Hospital de Especialidades, em Jalisco, México. Isso incluiu 100 olhos após a cirurgia de facoemulsificação pela presença de laser de femtosegundo, seguida por implante de lente intra-ocular difrativa tetrafocal devido à catarata ou cirurgia facorrefractiva. Foi medida a acuidade visual de longe, intermediária e de perto, e a presença ou ausência de fenômenos distópicos, além da satisfação do paciente após a cirurgia. Resultados: Um total de 100 olhos em 50 pacientes submetidos à cirurgia de catarata com facoemulsificação por femtosegundo foram avaliados. 100% foram submetidos a facoemulsificação bilateral. A acuidade visual para longe, intermediária e de perto após três meses foi na maioria dos pacientes 20/20 (46%), 20/15 (44%) e Jaeger 1 (48%) respectivamente. A porcentagem ou pacientes que se referem a halos foi de 7%; e outros sintomas associados em 18%, sendo a astenopia a mais prevalente. A remoção da lente não foi necessária em nenhum caso. Conclusão: A lente intra-ocular difrativa tetrafocal fornece excelente visão intermediária (a 60 centímetros) e acuidade visual satisfatória de perto a (30 centímetros) e de longe (6 metros).


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Phacoemulsification/methods , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Presbyopia/surgery , Presbyopia/diagnosis , Refraction, Ocular/physiology , Cataract/diagnosis , Visual Acuity/physiology , Retrospective Studies , Treatment Outcome , Patient Satisfaction , Observational Study
13.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(5): 377-380, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019430

ABSTRACT

ABSTRACT Purpose: To assess the frequency of corneal astigmatism before cataract surgery in a Brazilian sample. Methods: This clinic-based cross-sectional study was conducted at the Bonsucesso Federal Hospital, Rio de Janeiro, Brazil. Charts of patients who underwent cataract surgery over a two-year period were retrospectively reviewed, and preoperative keratometric measurements were collected and analyzed. Results: A total of 1707 eyes of 1045 patients were enrolled. The corneal astigmatism was less than 1.0 D in 971 eyes (56.9%), 1.0-1.99 D in 496 eyes (29.1%), 2.0-2.99 D in 157 eyes (9.2%), and more than 3.0 D in 83 eyes (4.9%). The mean corneal astigmatism was 0.92 ± (SD) 0.96 D (range 0 - 10.25 D). Conclusion: Over 40% of the patients undergoing cataract surgery enrolled in this study had more than 1.0 D of corneal astigmatism and may benefit from the use of toric intraocular lenses. These data can be useful for planning to make this technology available for patients.


RESUMO Objetivo: Avaliar a prevalência do astigmatismo corneano antes da cirurgia de catarata em pacientes brasileiros. Métodos: Este estudo transversal de base clínica foi realizado no Hospital Federal de Bonsucesso, Rio de Janeiro, Brasil. Os prontuários de pacientes submetidos à cirurgia de catarata durante um período de dois anos foram revisados retrospectivamente, e as medidas ceratométricas pré-operatórias foram coletadas e analisadas. Resultados: Um total de 1.707 olhos de 1045 pacientes foram incluídos. O astigmatismo corneano foi menor que 1,0 D em 971 olhos (56,9%), 1,0-1,99 D em 496 olhos (29,1%), 2,0-2,99 D em 157 olhos (9,2%) e mais de 3,0 D em 83 olhos (4,9%). A média do astigmatismo corneano foi de 0,92 ± (SD) 0,96 D (intervalo 0-10,25 D). Conclusão: Mais de 40% dos pacientes estudados submetidos à cirurgia de catarata incluídos neste estudo tinham mais de 1,0 D de astigmatismo corneano e podem se beneficiar do uso de lentes intraoculares tóricas. Esses dados podem ser úteis no planejar a disponibilização dessa tecnologia para os pacientes.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Astigmatism/epidemiology , Cataract/complications , Cataract Extraction , Corneal Diseases/epidemiology , Brazil/epidemiology , Prevalence , Cross-Sectional Studies , Retrospective Studies , Cornea/physiopathology , Hospitals, Public
14.
Rev. bras. oftalmol ; 77(5): 272-277, set.-out. 2018. tab, graf
Article in English | LILACS | ID: biblio-977871

ABSTRACT

Abstract Purpose: To report the prevalence and analyse corneal astigmatism patterns in cataract surgery candidates. Methods: Researchers examined 2136 eyes from 1204 patients for cataract surgery from 1 January to 31 December 2016. All the candidates were evaluated with partial coherence interferometry (IOLMaster). The results were analysed statistically in relation to qualitative and quantitative variables. Results: The mean age of the patients was 71.9 years with a female predominance. Mean corneal astigmatism was 1.0 dioptre (D). Against the rule (ATR) astigmatism increased with age. Women presented with steeper corneas than men. In those patients who had both eyes measured, we found strong correlations between amount of right and left eye astigmatism, axis and keratometry. Overall, 39% of the eyes had corneal astigmatism > 1.00 D and 19% >1.50 D. Conclusions: A significant percentage of our population presents with corneal astigmatism > 1.00 D with a shift from WTR (with the rule) to ATR with increasing age. Our findings, in a population that has never been described before, will be helpful to surgeons to enhance surgical techniques, patients to improve visual outcomes, IOL (intraocular lens) manufacturers to make better designs and health agents to optimise resources.


Resumo Objetivo: Relatar a prevalência e analisar os padrões de astigmatismo corneano em candidatos à cirurgia de catarata. Métodos: Os pesquisadores examinaram 2136 olhos de 1204 pacientes a cirurgia de catarata de 1 de janeiro a 31 de dezembro de 2016. Todos os candidatos foram avaliados com interferometria de coerência parcial (IOLMaster). Os resultados foram analisados estatisticamente em relação às variáveis qualitativa e quantitativa. Resultados: A média de idade dos pacientes foi de 71,9 anos, com predomínio do sexo feminino. A média de astigmatismo corneano foi de 1,0 dioptria (D). Contra a regra (ATR), o astigmatismo aumentou com a idade. As mulheres apresentaram córneas mais íngremes que os homens. Nos pacientes que tiveram os dois olhos medidos, encontramos fortes correlações entre quantidade de astigmatismo nos olhos direito e esquerdo, eixo e ceratometria. No geral, 39% dos olhos tinham astigmatismo corneano >1,00 D, e 19% > 1,50 D. Conclusões: Uma percentagem significativa da nossa população apresenta astigmatismo corneano >1,00, D com uma mudança de WTR (a favor da regra) para ATR (contra a regra) com o aumento da idade. Nossas descobertas em uma população que nunca foi descrita antes serão úteis para os cirurgiões melhorarem suas técnicas cirúrgicas, os pacientes melhorarem seus resultados visuais, os fabricantes de LIOs (lentes intraoculares) criarem projetos melhores, e os agentes de saúde otimizarem os recursos.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Astigmatism/epidemiology , Phacoemulsification/statistics & numerical data , Cornea/diagnostic imaging , Interferometry , Astigmatism/physiopathology , Cataract Extraction/statistics & numerical data , Prevalence , Biometry/instrumentation , Axial Length, Eye , Optical Imaging/instrumentation , Anterior Chamber
15.
Arq. bras. oftalmol ; Arq. bras. oftalmol;80(2): 114-117, Mar.-Apr. 2017. tab, graf
Article in English | LILACS | ID: biblio-838793

ABSTRACT

ABSTRACT Purpose: Artisan iris-claw lens implantation (AICLI) is a surgical technique for treating ectopia lentis. We aimed to compare visual outcomes and possible long-term complications of AICLI surgery in pediatric patients with ectopia lentis with or without a diagnosable hereditary disease. Methods: Seventeen children with non-traumatic ectopia lentis were retros pectively classified into two groups: group 1 included children with a diagnosable hereditary disease (11 patients, 65%), and group 2 included children without any definable hereditary disease (six patients, 35%). Patients were evaluated for post-surgical refraction, best-corrected visual acuity, and clinical follow-up complications. Results: The average follow-up time was 38 months, and the average age of the patients was 103 ± 53 months (30-196 months). Best-corrected visual acuity values were significantly increased in both groups after surgery (p<0.05). Target refraction values were achieved at a rate of 47% in group 1 and 22% in group 2. Post-surgery complications, such as lens dislocation (36%, 11 eyes of 10 patients) and hypotonia (10%, three eyes of three patients) were observed in both groups, and retinal detachments (10%, three eyes of three patients) were observed in three patients from group 1. Conclusions: Compared with previous similar studies, this study utilized the largest pediatric patient group and had the longest post-surgery follow-up time. Moreover, it is advisable that pediatric patients with non-traumatic ectopia lentis be carefully screened for any underlying hereditary disease, especially diseases related to connective tissue metabolism.


RESUMO Objetivo: A implantação de lentes intraoculares de fixação iriana em garra (AICLI) é uma técnica cirúrgica para o tratamento de ectopia lentis. Nosso objetivo foi comparar resultados visuais e possíveis complicações em longo prazo da cirurgia de AICLI em pacientes pediátricos com ectopia lentis com ou sem doença hereditária diagnosticável. Métodos: Dezessete crianças com ectopia lentis não-traumática foram classificadas retrospectivamente em dois grupos: o grupo 1 com pacientes apresentando doença hereditária diagnosticável (11 pacientes, 65%) e o grupo 2 com pacientes sem qualquer doença hereditária definível (6 pacientes, 35%). Os pacientes foram avaliados quanto à sua refração pós-operatória, acuidade visual melhor corrigida e complicações. Resultados: O tempo médio de seguimento foi 38 meses. A média de idade dos pacientes foi de 103 ± 53 meses (30-196 meses). Os valores de acuidade visual me lhor corrigida aumentaram significativamente em ambos os grupos (p<0,05). Os valores de refração alvo foram alcançados a uma taxa de 47% no grupo 1 e 22% no grupo 2. Complicações pós-operatórias como luxação da lente (36%, 11 olhos de 10 pacientes) e hipotonia (10%, 3 olhos de 3 pacientes) foram observados nos dois grupos e foram observados descolamentos de retina (10%, 3 olhos de 3 pacientes) em 3 pacientes do grupo 1. Conclusões: Em comparação com relatos anteriores na literatura, este estudo utilizou um grupo maior de pacientes pediátricos e tempo de seguimento pós-operatório mais longo. É aconselhável que pacientes pediátricos com ectopia lentis não-traumática sejam cuidadosamente selecionados em relação a doença subjacente hereditária, especialmente as doenças relacionadas com o metabolismo do tecido conjuntivo.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Ectopia Lentis/surgery , Lens Implantation, Intraocular/methods , Postoperative Complications , Refraction, Ocular , Retinal Detachment/etiology , Visual Acuity , Ectopia Lentis/complications , Lens Subluxation/etiology , Retrospective Studies , Follow-Up Studies , Treatment Outcome , Lens Implantation, Intraocular/adverse effects , Marfan Syndrome/surgery , Marfan Syndrome/complications , Muscle Hypotonia/etiology
16.
Arq. bras. oftalmol ; Arq. bras. oftalmol;79(3): 171-176, tab, graf
Article in English | LILACS | ID: lil-787325

ABSTRACT

ABSTRACT Purpose: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. Methods: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity (DCIVA), with analysis of contrast sensitivity (CS), wavefront, and visual defocus curve. Results: Postoperative UDVA was 0.09 and 0.08 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.868); postoperative CDVA was 0.04 and 0.02 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.68); DCIVA was 0.17 and 0.54 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.000); and DCNVA was 0.04 and 0.09 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.001). In both cases, there was an improvement in the spherical equivalent and UDVA (p<0.05). Under photopic conditions, the SN6AD1 group had better CS at low frequencies without glare (p=0.04); however, the ZMB00 group achieved better sensitivity at high frequencies with glare (p=0.003). The SN6AD1 and ZMB00 lenses exhibited similar behavior for intermediate vision, according to the defocus curve; however, the ZMB00 group showed a shorter reading distance than the SN6AD1 group. There were no significant differences regarding aberrometry between the two groups. Conclusion: Both lenses promoted better quality of vision for both long and short distances and exhibited a similar behavior for intermediate vision. The SN6AD1 and ZMB00 groups showed better results for CS under photopic conditions at low and high spatial frequencies, respectively.


RESUMO Objetivo: Comparar o desempenho óptico e resultado visual entre duas lentes multifocais difrativas: AMO Tecnis® ZMB00 e AcrySof® ReSTOR® SN6AD1. Métodos: O estudo prospectivo, comparativo não randomizado incluiu avaliação de 74 olhos em 37 pacientes com indicação de facectomia e candidatos a implante de lente multifocal. Critérios de exclusão foram: presença de outras doenças oculares; cirurgia ocular prévia; alta miopia axial; astigmatismo cornenano maior que 1,00 D cilíndrica; complicações intraoperatórias ou pós-operatórias. A avaliação oftalmológica contou com medida da acuidade visual para longe corrigida (CDVA) e não corrigida (UDVA), intermediária (DCIVA) e curta distância (DCNVA) com melhor correção óptica para longe; teste de sensibilidade ao contraste; análise de frente de onda e curva visual de Defocus. Resultados: A UDVA foi de 0,09 logMAR para o grupo SN6AD1 e 0,08 logMAR para o grupo ZMB00; com correção foi de 0,04 logMAR para SN6AD1 e 0,02 para o grupo ZMB00 (p>0,05). O grupo SN6AD1 obteve valor de 0,04 logMAR e o grupo ZMB00 de 0,09 logMAR para DCNVA (p<0,05) e DCIVA de 0,17 logMAR para SN6AD1 e 0,54 logMAR para ZMB00 (p=0,000). Houve melhora do equivalente esférico e da UDVA em ambos os grupos (p<0,05). Em condições fotópicas, o grupo SN6AD1 teve melhor sensibilidade ao contraste em baixas frequências sem ofuscamento (p<0,05), contudo grupo ZMB00 obteve melhor sensibilidade em altas frequências (p<0,05) com ofuscamento. As lentes SN6AD1 e ZMB00 obtiveram comportamento semelhantes para visão intermediária na curva de Defocus, porém, o grupo ZMB00 mostrou menor distância de leitura que o grupo SN6AD1. Não houve diferença com significância estatística relacionada à aberrometria na comparação dos dois grupos. Conclusão: As duas lentes promoveram melhor qualidade de visão para longe e perto e comportamento semelhante para visão intermediária. O grupo ZMB00 exibiu melhores resultados para sensibilidade ao contraste em condições fotópicas em alta frequência espacial e SN6AD1 em baixa frequência espacial.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Visual Acuity/physiology , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Postoperative Period , Prosthesis Design , Reference Values , Refraction, Ocular , Analysis of Variance , Treatment Outcome , Aberrometry , Preoperative Period
17.
Arq. bras. oftalmol ; Arq. bras. oftalmol;79(1): 19-23, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-771898

ABSTRACT

ABSTRACT Purpose: To evaluate the ocular axial length (AL) and keratometry (K) in Brazilian children with congenital/developmental cataract, assess the differences and evolution of AL and K according to age, and establish functional models of AL and K as function of age. Methods: Children with congenital/developmental cataract aged 1.5 months old to 8 years old and no other ocular diseases were included. All eyes with unilateral cataract, the left eyes from children with bilateral cataracts, and healthy eyes from children with unilateral cataract were analyzed. After the administration of anesthesia, K was measured with a portable automatic keratometer, and AL was measured with a contact biometer. Cataract surgery was performed immediately after the measurements were taken. The data were statistically analyzed, and a linear regression with an age logarithm was used to model the relationship. Results: Forty-four eyes with cataract were included in this analysis, comprising 15 eyes with unilateral cataract and 29 left eyes from children with bilateral cataracts. The mean age was 27.3 months with a mean AL of 20.63 ± 2.11 mm and a mean K of 44.94 ± 2.44 D. The K value was significantly steeper and the AL value was significantly shorter in younger children (P< 0.001). No significant differences were found neither between eyes with unilateral and bilateral cataracts nor between eyes with unilateral cataract and their corresponding healthy eyes (P >0.05). Conclusion: The values of K and AL significantly change with age, especially during the first 6 months of life. A linear functional relationship between K and AL with the logarithm of age and between K and AL was established.


RESUMO Objetivo: Avaliar o comprimento axial (AL) e a ceratometria (K) de olhos de crianças brasileiras com catarata congênita/desenvolvimento, analisar diferenças e evoluções de acordo com a idade e estabelecer modelos funcionais de comprimento axial e ceratometria em função da idade e entre eles. Métodos: Crianças com catarata congênita/desenvolvimento com idade de 1,5 meses a 8 anos de idade e sem outras doenças oculares foram incluídas. Todos os olhos com catarata unilateral, o olho esquerdo de crianças com catarata bilateral e o olho sadio de crianças com catarata unilateral foram analisados. Após a administração de anestesia, a ceratometria foi obtida com um ceratômetro automático portátil e o comprimento axial medido com um biômetro de contato. Em seguida, a cirurgia de catarata foi realizada. Os dados foram analisados estatisticamente, a regressão linear com o logaritmo da idade foi utilizado para modelar os relacionamentos. Resultados: Todos os olhos com catarata unilateral (n=15) e um olho selecionados aleatoriamente a partir dos casos bilaterais (n=29) foram incluídos na análise (total= 44 olhos). A idade média foi de 27,3 meses, as médias do comprimento axial e da ceratometria foram respectivamente 20,63 ± 2,11 mm e 44,94 ± 2,44 dioptrias. A ceratometria foi significativamente mais curvo e comprimento axial significantemente mais curto em crianças mais jovens (P<0,001). Não foram encontradas diferenças significativas na comparação entre os olhos com cataratas unilaterais e bilaterais e comparando os olhos com catarata unilateral a correspondentes olhos saudáveis (P>0,05). Conclusão: Os valores de ceratometria e comprimento axial mudam significativamente com a idade, principalmente nos primeiros seis meses de vida. Foi estabelecida uma relação funcional linear entre comprimento axial e ceratometria com o logaritmo da idade e entre ceratometria e comprimento axial.


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Axial Length, Eye/pathology , Cataract/congenital , Cataract/pathology , Cornea/pathology , Age Factors , Brazil , Biometry/methods , Cataract/physiopathology , Linear Models , Reference Values , Retrospective Studies
18.
Arq. bras. oftalmol ; Arq. bras. oftalmol;78(5): 313-317, Sep.-Oct. 2015. tab, ilus
Article in English | LILACS | ID: lil-761517

ABSTRACT

ABSTRACTPurpose:To report and compare the surgical, visual, and anatomical outcomes following treatment of dislocated intraocular lenses (IOLs).Methods:The medical records of 28 eyes of 28 patients were evaluated. Age, gender, pre-and postoperative best-corrected visual acuity (BCVA), surgical methods, and complications were recorded.Results:Pre-and postoperative BCVA ranged from counting fingers to 20/32 and from counting fingers to 20/25, respectively. Late-onset dislocations were the most frequently observed complication. The most frequent surgical method was IOL repositioning in 15 of 28 patients, followed by IOL exchange in 11 patients, and IOL removal in 2 patients. Only 1 patient required surgical re-intervention with IOL capture.Conclusions:Visual acuity improved following the use of either IOL repositioning or IOL exchange. No superiority of one method over the other was observed. In the present retrospective case series, management of dislocated IOLs with repositioning or exchange of the primary implant conferred comparable surgical and visual outcomes.


RESUMOObjetivo:Relatar e comparar as abordagens cirúrgicas e os resultados visuais e anatômicos no tratamento de lentes intraoculares (IOL) deslocadas.Métodos:Foram avaliados os registros médicos de 28 olhos de 28 pacientes. Idade, sexo, melhor acuidade visual corrigida pré e pós-operatória, abordagens cirúrgicas e complicações foram registrados.Resultados:Melhor acuidade visual corrigida pré e pós-operatória variou de conta dedos a 20/32 e de conta dedos a 20/25, respectivamente. Os deslocamentos tardios foram os mais frequentemente encontrados. A cirurgia mais frequente foi o reposicionamento da IOL em 15 dos 28 pacientes, em seguida, o troca da IOL em 11 pacientes, e a remoção da IOL em dois pacientes. Apenas um caso de necessitou de reintervenção devido à captura da IOL.Conclusões:A acuidade visual melhorou em ambas as abordagens, reposicionamento e troca de IOL. Não houve superioridade de um método sobre o outro. Na presente série de casos retrospectiva, o tratamento do deslocamento de IOL com reposição ou troca do implante primário gerou resultados cirúrgicos e visuais comparáveis.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Young Adult , Artificial Lens Implant Migration/surgery , Lens Implantation, Intraocular/methods , Lenses, Intraocular/adverse effects , Artificial Lens Implant Migration/physiopathology , Lens Implantation, Intraocular/adverse effects , Medical Records , Postoperative Complications/etiology , Retrospective Studies , Sclera/surgery , Time Factors , Treatment Outcome , Visual Acuity , Vitrectomy/methods , Vitreous Body/surgery
19.
Arq. bras. oftalmol ; Arq. bras. oftalmol;78(3): 154-157, May-Jun/2015. tab
Article in English | LILACS | ID: lil-753018

ABSTRACT

ABSTRACT Purpose: To analyze the indications for explantation or exchange of intraocular lenses (IOLs), which were originally implanted for the correction of aphakia during cataract extraction. Methods: All cases that involved intraocular lens explantation or exchange in one institution between January 2008 and December 2014 were analyzed retrospectively. Results: In total, 93 eyes of 93 patients were analyzed. The median time interval between implantation and explantation of the anterior chamber intraocular lenses (AC IOL) and posterior chamber intraocular lenses (PC IOL) was 83.40 ± 83.14 months (range: 1-276 months) and 55.14 ± 39.25 months (range: 1-168 months), respectively. Pseudophakic bullous keratopathy (17 eyes, 38.6%) and persistent iritis (12 eyes, 27.8%) in the AC IOL group and dislocation or decentration (30 eyes, 61.2%) and incorrect IOL power (nine eyes, 18.4%) in the PC IOL group were the most common indications for explantation of IOLs. The mean logMAR best corrected visual acuity (BCVA) improved significantly from 1.30 preoperatively to 0.62 postoperatively in the PC IOL group (p<0.001) but did not improve significantly in the AC IOL group (p=0.186). Conclusions: The primary indication for IOL explantation or exchange was pseudophakic bullous keratopathy in the AC IOL group and was dislocation or decentration in the PC IOL group. PC IOL explantation or exchange is safe and improves visual acuity. .


RESUMO Objetivo: Analisar as indicações para a remoção ou troca de lentes intraoculares (IOL), que foram originalmente implantadas para a correção de afacia após a extração da catarata. Método: Todos os casos que envolveram remoção ou troca de lentes intraoculares em uma única instituição, entre janeiro de 2008 e dezembro 2014 foram analisados retrospectivamente. Resultados: No total, foram analisados 93 olhos de 93 pacientes. O intervalo de tempo médio entre o implante e a remoção das LIOs de câmara anterior (AC IOL) e de câmara posterior (PC IOL) foi 83,40 ± 83,14 meses (variando de 1 a 276 meses) e 55,14 ± 39,25 meses (variando de 1 a 168 meses), respectivamente. Ceratopatia bolhosa pseudofácica (17 olhos, 38,6%) e irite persistente (12 olhos, 27,8%) no grupo AC IOL, e deslocamento ou descentralização (30 olhos, 61,2%) e poder incorreto da IOL (nove olhos, 18,4%), no grupo PC IOL, foram as indicações mais comuns para a remoção das IOLs. A média logMAR da melhor acuidade visual corrigida (BCVA) melhorou significativamente a partir de 1,30 no pré-operatório para 0,62 no pós-operatório no grupo PC IOL (p<0,001), mas não melhorou significativamente no grupo AC IOL (p=0,186). Conclusões: A principal indicação para remoção ou troca de lentes intraoculares foi a ceratopatia bolhosa pesudofácica no grupo AC IOL e deslocamento ou descentralização no grupo PC IOL. A remoção ou troca de PC IOLs é segura e melhora a acuidade visual. .


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Humans , Male , Middle Aged , Young Adult , Corneal Diseases/surgery , Device Removal/methods , Intraoperative Complications , Lens Implantation, Intraocular/methods , Refractive Errors/complications , Corneal Diseases/complications , Intraocular Pressure , Iritis/complications , Iritis/surgery , Lens Implantation, Intraocular/adverse effects , Lens Subluxation/surgery , Reoperation , Retrospective Studies , Treatment Outcome , Visual Acuity
20.
Rev. bras. oftalmol ; 74(3): 189-193, May-Jun/2015.
Article in English | LILACS | ID: lil-764235

ABSTRACT

Pediatric cataract is the most common treatable cause of blindness in children. Prevalence, etiology and morphology vary with the socioeconomic development. The treatment goal is to reduce amblyopia, being difficult management especially in unilateral cases. The decision on aphakia or primary intraocular lens should be individualized as well as correction with contact lens or spectacles. The intraocular lens single-piece hydrophobic acrylic are the most implanted in children and the preferably is in the capsular bag. The Sanders-Retzlaff-Kraff theoretic (SRK/T) stressing that is described as more predictable, following Holladay I and SRK II and the recommendation is to under correction +6.0 or +8.0 dioptrias expecting the growth of the eye. The posterior capsule opacity is the most frequent complication and varies with the material choice of the lens. Glaucoma is the most serious postoperative complication and depends on the timing of the surgery, primary lens implantation and time of post surgical follow-up. The adherence to occlusion therapy with patching is critical to the visual prognosis and is determined by the child’s age and laterality of the cataract. There was significant improvement in the surgery and in IOLs, however the final visual prognosis is still not desirable.


A catarata pediátrica é a causa mais comum de cegueira tratável em crianças. Prevalência, etiologia e morfologia variam conforme o desenvolvimento sócioeconômico. O tratamento tem como objetivo diminuir a ambliopia, sendo de difícil manejo principalmente em casos unilaterais. A decisão sobre afacia ou implante primário de lente intraocular deve ser individualizado, assim como a correção com lente de contato ou óculos. As lentes intraoculares acrílicas hidrofóbicas de peça única são as mais implantadas em crianças com preferência de implante no saco capsular. A fórmula biométrica Sanders-Retzlaff-Krafftheoretic (SRK/T) é a mais precisa em pacientes pediátricos, seguida de Holladay I e SRK II, com recomendação de sob correção de +6 a +8.0 dioptrias, devido ao esperado crescimento rápido do globo ocular. A opacidade de cápsula posterior é a complicação mais frequente e varia com o material da lente a ser implantada e o glaucoma é a complicação pós-operatória mais grave e depende da idade da criança na cirurgia, implante primário de LIOs e da duração do acompanhamento pós-cirúrgico. A adesão ao tratamento oclusivo é fundamental para o prognóstico visual, sendo determinado de acordo com a idade da criança e a lateralidade da catarata. Mesmo com a melhora do tratamento cirúrgico e das lentes intraoculares o prognóstico visual final ainda não é o desejável.


Subject(s)
Humans , Infant, Newborn , Infant , Child, Preschool , Aphakia, Postcataract/rehabilitation , Cataract Extraction , Contact Lenses , Cataract/congenital , Cataract/etiology , Lenses, Intraocular , Prognosis
SELECTION OF CITATIONS
SEARCH DETAIL