Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 449
Filter
1.
Clin Res Cardiol ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38953944

ABSTRACT

BACKGROUND: Substantial controversy exists regarding the clinical benefit of patients with severe paradoxical low-flow, low-gradient aortic stenosis (PLF-LG AS) from TAVI. Therefore, we compared post-TAVI benefit by long-term mortality (all-cause, CV and SCD), clinical improvement of heart failure symptoms, and cardiac reverse remodelling in guideline-defined AS subtypes. METHODS: We prospectively included 250 consecutive TAVI patients. TTE, 6mwt, MLHFQ, NYHA status and NT-proBNP were recorded at baseline and 6 months. Long-term mortality and causes of death were assessed. RESULTS: 107 individuals suffered from normal EF, high gradient AS (NEF-HG AS), 36 from low EF, high gradient AS (LEF-HG), 52 from "classic" low-flow, low-gradient AS (LEF-LG AS), and 38 from paradoxical low-flow, low-gradient AS (PLF-LG AS). TAVI lead to a significant decrease in MLHFQ score and NT-proBNP levels in all subtypes except for PLF-LG. Regarding reverse remodelling, a significant increase in EF and decrease in LVEDV was present only in subtypes with reduced baseline EF, whereas a significant decrease in LVMI and LAVI could be observed in all subtypes except for PLF-LG. During a follow-up of 3-5 years, PLF-LG patients exhibited the poorest survival among all subtypes (HR 4.2, P = 0.0002 for CV mortality; HR 7.3, P = 0.004 for SCD, in comparison with NEF-HG). Importantly, PLF-LG was independently predictive for CV mortality (HR 2.9 [1.3-6.9], P = 0.009). CONCLUSIONS: PLF-LG patients exhibit the highest mortality (particularly CV and SCD), the poorest symptomatic benefit and the least reverse cardiac remodelling after TAVI among all subtypes. Thus, this cohort seems to gain the least benefit.

2.
Environ Monit Assess ; 196(8): 688, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38958799

ABSTRACT

Rivers are vital and complex natural systems that provide a wide range of ecosystem services. This study presents a methodology for assessing the riverine provisioning and supporting ecosystem services, whose applicability has been demonstrated over the Budhabalanga River Basin of India. The Soil and Water Assessment Tool (SWAT) is used to generate streamflow time series at various ungauged sites, and then the streamflow is characterized for the evaluation of provisioning services. Further, the diversity and abundance of macroinvertebrates, along with the Lotic-invertebrate Index for Flow Evaluation (LIFE), is used to study the riverine supporting ecosystem services. The streams show intermittent behavior and strong seasonality for low flows, which limits the water availability, particularly during pre-monsoon season. The Baseflow Index (BFI) is greater than 0.6, indicating that groundwater contributes more than 60% of the total streamflow. Interestingly, despite the high BFI, the streams did not conform to the prevailing opinion that a greater baseflow contribution results in a later commencement of the low-flow period in the hydrological year. Furthermore, the study depicts significant variations in the diversity and abundance of the macroinvertebrates across the various sampling sites. However, the LIFE score across the sites remained consistent within a narrow range, i.e., 8 to 9, suggesting a steady supply of supporting ecosystem services. The results of the study can help the policymakers towards an informed decision making and the simplistic methodology proposed in this study can be replicated in other river basins for identifying vulnerable watersheds and prioritizing management actions.


Subject(s)
Ecosystem , Environmental Monitoring , Hydrology , Rivers , India , Environmental Monitoring/methods , Animals , Invertebrates , Conservation of Natural Resources/methods , Biodiversity , Groundwater
3.
Article in English | MEDLINE | ID: mdl-38972614

ABSTRACT

IMPORTANCE: Guidelines recommend the use of Dobutamine stress echocardiography (DSE) in patients with low-gradient aortic stenosis (AS) and left ventricular ejection fraction (LVEF) <50%. However, a paucity exists in DSE data when LVEF>35%. OBJECTIVE: To examine the diagnostic accuracy of DSE, in patients with low-gradient AS with a wide range of LVEF and to examine the interaction between the diagnostic accuracy of DSE and LVEF. DESIGN, SETTING AND PARTICIPANTS: Patients with mean-gradient<40 mmHg, AVA<1.0 cm2, and stroke volume index≤35 mL/m2 undergoing DSE and Cardiac Computer Tomography (C-CT) were identified from three prospectively collected patient cohorts, and stratified according to LVEF; LVEF<35%, LVEF 35-50% & LVEF>50%. EXPOSURE: DSE and C-CT was performed on patients with low-gradient AS MAIN OUTCOMES AND MEASURES: Severe AS was defined as AVC score ≥2000 AU among men, and ≥1200 AU for women on C-CT. RESULTS: Of 221 patients included in the study, 78 (35%) presented with LVEF<35%, 67 (30%) with LVEF 35-50%, and 76 (34%) with LVEF>50%. Mean-gradient and Vmax during DSE showed significantly diagnostic heterogeneity between LVEF groups, being most precise when LVEF<35% (both AUC=0.90), albeit with optimal thresholds of 30 mmHg & 377 cm/s, and a limited diagnostic yield in patients with LVEF≥35% (AUC=0.67 & 0.66 in LVEF 35-50% and AUC=0.65 & 0.60 in LVEF≥50%). Using guideline thresholds led to a sensitivity/specificity of 49%/84% for all patients with LVEF<50%. CONCLUSION AND RELEVANCE: While DSE is safe and leads to an increase in stroke volume in patients with low-gradient AS regardless of LVEF, the association between DSE gradients and AS severity assessed by C-CT demonstrates important heterogeneity depending on LVEF, with highest accuracy in patients with LVEF<35%.

5.
J Cardiovasc Dev Dis ; 11(6)2024 May 23.
Article in English | MEDLINE | ID: mdl-38921662

ABSTRACT

Aortic stenosis (AS) is the most prevalent degenerative valvular disease in western countries. Transthoracic echocardiography (TTE) is considered, nowadays, to be the main imaging technique for the work-up of AS due to high availability, safety, low cost, and excellent capacity to evaluate aortic valve (AV) morphology and function. Despite the diagnosis of AS being considered straightforward for a very long time, based on high gradients and reduced aortic valve area (AVA), many patients with AS represent a real dilemma for cardiologist. On the one hand, the acoustic window may be inadequate and the TTE limited in some cases. On the other hand, a growing body of evidence shows that patients with low gradients (due to systolic dysfunction, concentric hypertrophy or coexistence of another valve disease such as mitral stenosis or regurgitation) may develop severe AS (low-flow low-gradient severe AS) with a similar or even worse prognosis. The use of complementary imaging techniques such as transesophageal echocardiography (TEE), multidetector computed tomography (MDTC), or cardiac magnetic resonance (CMR) plays a key role in such scenarios. The aim of this review is to summarize the diagnostic challenges associated with patients with AS and the advantages of a comprehensive multimodality cardiac imaging (MCI) approach to reach a precise grading of the disease, a crucial factor to warrant an adequate management of patients.

6.
Indian J Radiol Imaging ; 34(3): 539-544, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38912249

ABSTRACT

For a safe sclerotherapy session to be completed in the orbital low-flow malformation (namely lymphovenous malformation or venolymphatic malformation), accurate identification of the target lesion for the drug injection is crucial. Regarding the dependability and viability of the injection approach, the authors have discussed their experiences with image-guided percutaneous sclerotherapy on a few patients.

7.
Am J Cardiol ; 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38925261

ABSTRACT

Low-flow (LF) aortic stenosis (AS) is common among older adults and associated with worse outcomes than AS with normal stroke volume. It is unknown whether left ventricular (LV) remodeling identifies patients with LF AS at higher risk of complications. LV remodeling was evaluated in 463 patients with severe LF AS referred for transcatheter aortic valve replacement (TAVR) and classified as adaptive (normal geometry and concentric remodeling) or maladaptive (concentric and eccentric hypertrophy) using the American Society of Echocardiography gender-specific criteria. Of these, the 390 patients who underwent TAVR were followed for the end points of heart failure (HF) hospitalization and all-cause mortality. The mean patient age was 79 (74.5 to 84) years. LV remodeling was adaptive in 57.4% (62 normal geometry, 162 concentric remodeling) and maladaptive in 42.6% (127 concentric hypertrophy, 39 eccentric hypertrophy). During a median follow-up of 3 years, 45 patients (11.5%) were hospitalized for HF and 73 (18.7%) died. After adjustment for widely used echocardiographic parameters, maladaptive remodeling was independently associated with HF hospitalization and death (adjusted hazard ratio 1.75, confidence interval 1.03 to 3.00). There was no significant difference between men and women in the association of maladaptive LV remodeling with the composite outcome (p = 0.40 for men and p = 0.06 for women). In conclusion, in patients with LF AS, maladaptive LV remodeling before TAVR is independently associated with higher incidences of postprocedural HF rehospitalization and death in both men and women. Assessment of LV remodeling has prognostic value over and above LV ejection fraction and may improve risk stratification for patients with LF AS.

8.
J Clin Monit Comput ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38822941

ABSTRACT

Nitric oxide (NO), a selective pulmonary vasodilator, can be delivered via conventional ICU and anesthesia machine ventilators. Anesthesia machines are designed for rebreathing of circulating gases, reducing volatile anesthetic agent quantity used. Current cylinder- and ionizing-based NO delivery technologies use breathing circuit flow to determine NO delivery and do not account for recirculated gases; therefore, they cannot accurately dose NO at FGF below patient minute ventilation (MV). A novel, cassette-based NO delivery system (GENOSYL® DS, Vero Biotech Inc.) uses measured NO concentration in the breathing circuit as an input to an advanced feedback control algorithm, providing accurate NO delivery regardless of FGF and recirculation of gases. This study evaluated GENOSYL® DS accuracy with different anesthesia machines, ventilation parameters, FGFs, and volatile anesthetics. GENOSYL® DS was tested with GE Aisys and Dräger Fabius anesthesia machines to determine NO dose accuracy with FGF < patient MV, and with a Getinge Flow-i anesthesia machine to determine NO dose accuracy when delivering various volatile anesthetic agents. Neonatal and adult mechanical ventilation parameters and circuits were used. GENOSYL® DS maintained accurate NO delivery with all three anesthesia machines, at low FGF with recirculation of gases, and with all volatile anesthetic agents at different concentrations. Measured NO2 levels remained acceptable at ≤ 1 ppm with set NO dose ≤ 40 ppm. GENOSYL® DS, with its advanced feedback control algorithm, is the only NO delivery system capable of accurately dosing NO with anesthesia machines with rebreathing ventilation parameters (FGF < MV) regardless of anesthetic agent.

9.
Eur J Heart Fail ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38887164

ABSTRACT

AIMS: Paradoxical low-flow, low-gradient aortic stenosis (pLFLG AS) may represent a diagnostic challenge, and its pathophysiology is complex. While left ventricular (LV) systolic function is preserved, right ventricular dysfunction (RVD) and consecutive LV underfilling may contribute to low-flow and reduced stroke volume index, and to adverse outcomes following transcatheter aortic valve implantation (TAVI). The aim of this study was to evaluate the potential role of RVD in pLFLG AS, and to assess the impact of pre-procedural RVD on clinical outcomes after TAVI in patients with pLFLG AS. METHODS AND RESULTS: Out of 2739 native AS patients, who received TAVI at the University of Cologne Heart Center between March 2013 and June 2021, 114 patients displayed pLFLG AS and were included in this study. Right ventricular (RV) function was assessed by transthoracic echocardiography, and a fractional area change (FAC) ≤35% and/or a tricuspid annular plane systolic excursion (TAPSE) <18 mm determined RVD. In addition, the TAPSE/systolic pulmonary artery pressure ratio (TAPSE/sPAP) was monitored as a measure of RV-pulmonary arterial (PA) coupling. An impaired FAC and TAPSE was present in 21.9% and 45.6% of patients, respectively, identifying RVD in 50.0%. RVD (p = 0.016), reduced FAC (p = 0.049), reduced TAPSE (p = 0.035) and impaired RV-PA coupling (TAPSE/sPAP ratio <0.31 mm/mmHg; p = 0.009) were associated with significantly higher all-cause mortality compared to patients with normal RV function. After adjustment for sex, age, body mass index, EuroSCORE II, previous myocardial infarction and mitral regurgitation, independent predictors for all-cause mortality were FAC, sPAP, TAPSE/sPAP ratio, right atrial area, RV diameter and tricuspid regurgitation. CONCLUSIONS: Adverse RV remodelling, RVD and impaired RV-PA coupling provide an explanation for low-flow and reduced stroke volume index in a subset of patients with pLFLG AS, and are associated with excess mortality after TAVI.

10.
Int J Pediatr Otorhinolaryngol ; 182: 111999, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38850598

ABSTRACT

OBJECTIVE: Atraumatic cerebrospinal fluid (CSF) rhinorrhea is uncommon in children and necessitates a multi-disciplinary evaluation for an etiology. Underlying osseous abnormality due to extensive or multifocal low flow vascular anomaly should be considered as a potential cause of spontaneous CSF leak. Treatment of multifocal low flow vascular anomalies may include medical and surgical approaches. In this series, we seek to determine the presenting signs and symptoms and medical and surgical treatment options for multifocal or extensive low flow vascular anomalies. METHODS: A retrospective case series at a quaternary care children's hospital was compiled. All children with CSF rhinorrhea diagnosed and treated for multifocal low flow vascular anomalies at our institution were included. A total of four patients were identified. RESULTS: All four patients had delay in initial diagnosis of underlying cause of meningitis and CSF rhinorrhea. Average age at diagnosis of multifocal low flow vascular anomaly was 7 years. This was on average 4 years after initial presentation for medical attention. Treatment approach was multidisciplinary and included medical management with sirolimus and bisphosphonates as well as surgical approaches to the skull base (lateral and anterior) to prevent CSF egress. CONCLUSION: Consideration of multifocal low flow vascular anomaly should be included in any pediatric patient presenting with CSF rhinorrhea.

11.
J Intensive Care ; 12(1): 22, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38863061

ABSTRACT

BACKGROUND: In out-of-hospital cardiac arrest (OHCA) patients with extracorporeal cardiopulmonary resuscitation (ECPR), the association between low-flow time and outcomes in accidental hypothermia (AH) patients compared to those of patients without AH has not been fully investigated. METHODS: This was a secondary analysis of the retrospective multicenter registry in Japan. We enrolled patients aged ≥ 18 years who had been admitted to the emergency department for OHCA and had undergone ECPR between January, 2013 and December, 2018. AH was defined as an arrival body temperature below 32 °C. The primary outcome was survival to discharge. Cubic spline analyses were performed to assess the non-linear associations between low-flow time and outcomes stratified by the presence of AH. We also analyzed the interaction between low-flow time and the presence of AH. RESULTS: Of 1252 eligible patients, 105 (8.4%) and 1147 (91.6%) were in the AH and non-AH groups, respectively. Median low-flow time was 60 (47-79) min in the AH group and 51 (42-62) min in the non-AH group. The survival discharge rates in the AH and non-AH groups were 44.8% and 25.4%, respectively. The cubic spline analyses showed that survival discharge rate remained constant regardless of low-flow time in the AH group. Conversely, a decreasing trend was identified in the survival discharge rate with longer low-flow time in the non-AH group. The interaction analysis revealed a significant interaction between low-flow time and AH in survival discharge rate (p for interaction = 0.048). CONCLUSIONS: OHCA patients with arrival body temperature < 32 °C who had received ECPR had relatively good survival outcomes regardless of low-flow time, in contrast to those of patients without AH.

12.
Eur Heart J Suppl ; 26(Suppl 1): i113-i116, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38867870

ABSTRACT

Moderate aortic stenosis is associated with a worse prognosis than milder degrees. Pathophysiologically, this condition in a dysfunctional ventricle could lead to a further mechanism of haemodynamic worsening, so its treatment should lead to clinical advantages for the patient. The low risk of complications associated with percutaneous correction of aortic valve disease (transcatheter aortic valve implantation) should also be considered, which would seem to favour an interventional approach even in the aforementioned condition. However, sparse data and small population studies make this approach still controversial. Three randomized controlled trials are underway to shed definitive light on the topic.

13.
Cardiol Clin ; 42(3): 433-446, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38910026

ABSTRACT

Current guidelines of aortic stenosis (AS) management focus on valve parameters, LV systolic dysfunction, and symptoms; however, emerging data suggest that there may be benefit of aortic valve replacement before it becomes severe by present criteria. Myocardial assessment using novel multimodality imaging techniques exhibits subclinical myocardial injury and remodeling at various stages before guideline-directed interventions, which predicts adverse outcomes. This raises the question of whether implementing serial myocardial assessment should become part of the standard appraisal, thereby identifying high-risk patients aiming to minimize adverse outcomes.


Subject(s)
Aortic Valve Stenosis , Multimodal Imaging , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Multimodal Imaging/methods , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Myocardium/pathology , Magnetic Resonance Imaging, Cine/methods
14.
JACC Adv ; 3(3): 100853, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38938841

ABSTRACT

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

15.
JACC Adv ; 3(3): 100854, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38938842
16.
J Clin Med ; 13(12)2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38930024

ABSTRACT

Rest and stress echocardiography (SE) play a fundamental role in the evaluation of aortic valve stenosis (AS). According to the current guidelines for the echocardiographic evaluation of patients with aortic stenosis, four broad categories can be defined: high-gradient AS (mean gradient ≥ 40 mmHg, peak velocity ≥ 4 m/s, aortic valve area (AVA) ≤ 1 cm2 or indexed AVA ≤ 0.6 cm2/m2); low-flow, low-gradient AS with reduced ejection fraction (mean gradient < 40 mmHg, AVA ≤ 1 cm2, left ventricle ejection fraction (LVEF) < 50%, stroke volume index (Svi) ≤ 35 mL/m2); low-flow, low-gradient AS with preserved ejection fraction (mean gradient < 40 mmHg, AVA ≤ 1 cm2, LVEF ≥ 50%, SVi ≤ 35 mL/m2); and normal-flow, low-gradient AS with preserved ejection fraction (mean gradient < 40 mmHg, AVA ≤ 1 cm2, indexed AVA ≤ 0.6 cm2/m2, LVEF ≥ 50%, SVi > 35 mL/m2). Aortic valve replacement (AVR) is indicated with the onset of symptoms development or LVEF reduction. However, there is often mismatch between resting transthoracic echocardiography findings and patient's symptoms. In these discordant cases, SE and CT calcium scoring are among the indicated methods to guide the management decision making. Additionally, due to the increasing evidence that in asymptomatic severe aortic stenosis an early AVR instead of conservative treatment is associated with better outcomes, SE can help identify those that would benefit from an early AVR by revealing markers of poor prognosis. Low-flow, low-gradient AS represents a challenge both in diagnosis and in therapeutic management. Low-dose dobutamine SE is the recommended method to distinguish true-severe from pseudo-severe stenosis and assess the existence of flow (contractile) reserve to appropriately guide the need for intervention in these patients.

17.
Diagnostics (Basel) ; 14(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38732304

ABSTRACT

BACKGROUND: In infants treated with a low-flow nasal cannula (LFNC), the oxygen concentration delivered to the lungs (i.e., the effective FiO2) is difficult to estimate. The existing mathematical formulas rely on important assumptions regarding the values of respiratory parameters and, thus, may be inaccurate. We aimed to assess oxygen delivery by LFNC to small infants using realistic simulations on a mechanical breathing model. METHODS: A mechanical breathing simulator (infant upper-airway replica, single-space breathing compartment, electric motor, microcontroller) was developed. Breathing simulations (n = 1200) were performed at various tidal volume (VT), inspiratory time (Ti), and respiratory rate (RR) combinations and different cannula flows. RESULTS: Minute ventilation (MV) was the most significant predictor of effective FiO2. FiO2 was higher at lower VT and higher Ti values. Benaron and Benitz's formula underestimated the effective FiO2 at lower MV values, while Finer's formula significantly overestimated it. A set of predictive FiO2 charts was developed based on cannula flow, infant body weight, and RR. CONCLUSIONS: The effective FiO2 delivered by LFNC to small infants critically depends on VT, Ti, and RR. However, since VT and Ti values are not available in clinical practice, the existing mathematical formulas may be inaccurate. Our novel predictive FiO2 charts could assist in optimizing oxygen delivery by LFNC using easy-to-obtain parameters, such as infant body weight and RR.

18.
JACC Case Rep ; 29(9): 102306, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38708427

ABSTRACT

Patients with paradoxical low-flow low-gradient aortic stenosis pose a diagnostic challenge when it comes to assessing the severity of aortic stenosis (AS) noninvasively. We describe 2 patients who underwent exercise cardiac catheterization to augment their cardiac output and assess the severity of AS invasively to allow differentiation of true severe AS from pseudo-severe AS.

19.
Article in English | MEDLINE | ID: mdl-38699658

ABSTRACT

Background: D2 aortic stenosis (AS) is the highest risk AS subtype with worse operative and mortality outcomes. This study aimed to investigate the quality of life (QoL) and left ventricular ejection fraction (LVEF) in patients with classic (D2 subtype) low-flow/low-gradient AS who underwent transcatheter aortic valve replacement (TAVR). Methods: In total, 634 patients with severe AS underwent TAVR at our institution from 2014 to 2020, of whom 76 met criteria for classic D2 AS with reduced LVEF. Echocardiographic and clinical outcomes including mortality, stroke, pacemaker placement (PPM), and readmission at baseline were compared with those at 30 days and 1 year. QoL data were extracted from the Kansas City Cardiomyopathy Questionnaire (KCCQ-12). Results: The average baseline Society of Thoracic Surgeons risk score for patients with D2 AS was 7.66 ± 6.76. Patients with D2 AS reported improved QoL post-TAVR. The average baseline KCCQ-12 score was 39.5 ± 20, with improvement to 68.9 ± 20.6 at 30 days (P < .01) and 74.9 ± 17.5 at 1 year (P < .01). Mortality was 0% at 30 days and 18.4% at 1 year. The average baseline LVEF was 36.1 ± 9.4. Left ventricular function improved to 43.5 ± 12.9 (P <.001) at 30 days and 46.3 ± 11.2 (P = .03) at 1 year. Complications post-TAVR at 30 days included stroke (1.3%) and PPM (11.8%). Patients with D2 AS exhibited higher baseline conduction defects including atrial fibrillation and higher postoperative PPM than those with other subtypes. Conclusions: Patients with D2 AS had significantly improved LVEF and QoL following TAVR at 30 days and 1 year. Postoperative rates of new PPM were higher than other subtypes, while stroke, dialysis, and mortality were lower than expected, supporting the benefit of TAVR in this high-risk group.

20.
Clin Res Cardiol ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748208

ABSTRACT

BACKGROUND: Right ventricular (RV) dysfunction in patients undergoing transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) has long been disregarded. We aimed to assess the predictive value of RV to pulmonary artery coupling (RV/PAc), defined as tricuspid annular plane systolic excursion to systolic pulmonary artery pressure, on mortality in different flow types of AS after TAVI. METHODS: All patients undergoing TAVI for AS at our centre between 2018 and 2020 were assessed; 862 patients were analysed. The cohort was dichotomized using a ROC analysis (cut-off 0.512 mm/mmHg), into 429 patients with preserved and 433 patients with reduced RV/PAc. RESULTS: Reduced RV/PAc was associated with male sex and a higher rate of comorbidities. Short-term VARC-3 endpoints and NYHA classes at follow-up were comparable. Reduced RV/PAc was associated with higher 2-year all-cause mortality (35.0% [30.3-39.3%] vs. 15.4% [11.9-18.7%], hazard ratio 2.5 [1.9-3.4], p < 0.001). Cardiovascular mortality was almost tripled. Results were consistent after statistical adjustment and in a multivariate model. Sub-analyses of AS flow types revealed lower RV/PAc in classical and paradoxical low-flow low-gradient AS, with the majority having reduced RV/PAc (74% and 59%). RV/PAc retained its predictive value in these subgroups. CONCLUSIONS: RV dysfunction defined by low RV/PAc is a strong mortality predictor after TAVI independent of flow group. It should be incorporated in future TAVI risk assessment.

SELECTION OF CITATIONS
SEARCH DETAIL
...