Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 358
Filter
1.
Article in English | MEDLINE | ID: mdl-39028425

ABSTRACT

INTRODUCTION: This study aims to assess 68Ga-Trivehexin PET/CT for detecting hyperfunctioning parathyroid tissue in comparison to [99mTc]Tc-MIBI scintigraphy-SPECT/CT (MIBI scan) in patients with primary hyperparathyroidism (PHPT). METHODS: The cohort comprised 13 patients diagnosed with PHPT based on biochemical analyses, including serum calcium, phosphorus, and parathyroid hormone (PTH) levels. Each participant underwent cervical ultrasonography, MIBI scan, and 68Ga-Trivehexin PET/CT imaging. Complementary 4D-CT and [18F]fluorocholine PET/CT were conducted in 7 patients. Ten lesions of 7 patients underwent PTH wash-out (WO) procedure. 68Ga-Trivehexin PET/CT findings were compared with other modalities and PTH-WO results. RESULTS: Ten patients had sporadic PHPT, while 3 were diagnosed with MEN-1 syndrome-associated PHPT. One patient did not have any identifiable parathyroid lesion across the imaging modalities. On a patient-based analysis, MIBI scan and 68Ga-Trivehexin PET/CT identified parathyroid lesions in 10 and 11 patients, respectively. However, 68Ga-Trivehexin PET/CT detected 7 additional parathyroid lesions that were negative on the MIBI scan. Consequently, 17 lesions were identified and confirmed as hyperfunctioning parathyroid tissue through imaging, PTH-WO, or a combination of both modalities. In lesion-based evaluation, 68Ga-Trivehexin identified 16 lesions compared to 10 by MIBI scan, resulting in a detection rate of 94.1% and 58.8%, respectively. Notably, in three patients who underwent [18F]fluorocholine PET/CT, no lesions were detected; yet 68Ga-Trivehexin PET/CT successfully identified parathyroid lesions in two of these patients. CONCLUSION: Our study provides the first evidence that 68Ga-Trivehexin PET/CT can effectively identify hyperfunctioning parathyroid tissue with a high detection rate warranting further investigations to comprehensively explore its potential in PHPT management.

2.
Diagnostics (Basel) ; 14(13)2024 Jun 30.
Article in English | MEDLINE | ID: mdl-39001288

ABSTRACT

BACKGROUND: Technology allows us to predict a histopathological diagnosis, but the high costs prevent the large-scale use of these possibilities. The current liberal indication for surgery in benign thyroid conditions led to a rising frequency of incidental thyroid carcinoma, especially low-risk papillary micro-carcinomas. METHODS: We selected a cohort of 148 patients with thyroid nodules by ultrasound characteristics and investigated them by fine needle aspiration cytology (FNAC)and prospective BRAF collection for 70 patients. Also, we selected 44 patients with thyroid nodules using semi-quantitative functional imaging with an oncological, 99mTc-methoxy-isobutyl-isonitrile (99mTc-MIBI) radiotracer. RESULTS: Following a correlation with final histopathological reports in patients who underwent thyroidectomy, we introduced the results in a machine learning program (AI) in order to obtain a pattern. For semi-quantitative functional visual pattern imaging, we found a sensitivity of 33%, a specificity of 66.67%, an accuracy of 60% and a negative predicting value (NPV) of 88.6%. For the wash-out index (WOind), we found a sensitivity of 57.14%, a specificity of 50%, an accuracy of 70% and an NPV of 90.06%.The results of BRAF in FNAC included 87.50% sensitivity, 75.00% specificity, 83.33% accuracy, 75.00% NPV and 87.50% PPV. The prevalence of malignancy in our small cohort was 11.4%. CONCLUSIONS: We intend to continue combining preoperative investigations such as molecular detection in FNAC, 99mTc-MIBI scanning and AI training with the obtained results on a larger cohort. The combination of these investigations may generate an efficient and cost-effective diagnostic tool, but confirmation of the results on a larger scale is necessary.

3.
Indian J Nucl Med ; 39(2): 148-149, 2024.
Article in English | MEDLINE | ID: mdl-38989320

ABSTRACT

Diffuse Tc-99m MIBI uptake in the lungs during parathyroid scintigraphy is exceptional, and only a few cases have described this unusual aspect. The differential diagnostic of this funding is a challenge when interpreting the examination, since it can be a sign of serious pathology. We report the case of unexpected diffusely increased Tc-99m MIBI uptake in bilateral lung fields in a patient with left cardiac dysfunction.

4.
Front Oncol ; 14: 1410057, 2024.
Article in English | MEDLINE | ID: mdl-38957316

ABSTRACT

A 54-year-old woman was admitted to the hospital with a left neck mass. Enhanced CT and ultrasound examinations revealed a lesion in the left sternocleidomastoid muscle. The patient undergone right thyroid lobe resection 8 years ago. Interestingly, the lesion on the sternocleidomastoid muscle, along with the left lobe of the patient's thyroid, visually appears to form a displaced and complete thyroid in the early Tc-99m-MIBI parathyroid scintigraphy. Combined with Tc-99m-MIBI scintigraphy and abnormal PTH and blood calcium levels, the consideration was given to the lesion in the sternocleidomastoid muscle as an ectopic parathyroid adenoma. Subsequent surgical pathology confirmed this suspicion.

5.
Expert Rev Endocrinol Metab ; 19(4): 317-333, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38899737

ABSTRACT

INTRODUCTION: Molecular imaging of thyroid and parathyroid diseases has changed in recent years due to the introduction of new radiopharmaceuticals and new imaging techniques. Accordingly, we provided an clinicians-oriented overview of such techniques and their indications. AREAS COVERED: A review of the literature was performed in the PubMed, Web of Science, and Scopus without time or language restrictions through the use of one or more fitting search criteria and terms as well as through screening of references in relevant selected papers. Literature up to and including December 2023 was included. Screening of titles/abstracts and removal of duplicates was performed and the full texts of the remaining potentially relevant articles were retrieved and reviewed. EXPERT OPINION: Thyroid and parathyroid scintigraphy remains integral in patients with thyrotoxicosis, thyroid nodules, differentiated thyroid cancer and, respectively, hyperparathyroidism. In the last years positron-emission tomography with different tracers emerged as a more accurate alternative in evaluating indeterminate thyroid nodules [18F-fluorodeoxyglucose (FDG)], differentiated thyroid cancer [124I-iodide, 18F-tetrafluoroborate, 18F-FDG] and hyperparathyroidism [18F-fluorocholine]. Other PET tracers are useful in evaluating relapsing/advanced forms of medullary thyroid cancer (18F-FDOPA) and selecting patients with advanced follicular and medullary thyroid cancers for theranostic treatments (68Ga/177Ga-somatostatin analogues).


Subject(s)
Molecular Imaging , Parathyroid Diseases , Radiopharmaceuticals , Thyroid Diseases , Humans , Molecular Imaging/methods , Parathyroid Diseases/diagnostic imaging , Thyroid Diseases/diagnostic imaging , Positron-Emission Tomography
6.
Methods Cell Biol ; 186: 213-231, 2024.
Article in English | MEDLINE | ID: mdl-38705600

ABSTRACT

Advancements in multiplexed tissue imaging technologies are vital in shaping our understanding of tissue microenvironmental influences in disease contexts. These technologies now allow us to relate the phenotype of individual cells to their higher-order roles in tissue organization and function. Multiplexed Ion Beam Imaging (MIBI) is one of such technologies, which uses metal isotope-labeled antibodies and secondary ion mass spectrometry (SIMS) to image more than 40 protein markers simultaneously within a single tissue section. Here, we describe an optimized MIBI workflow for high-plex analysis of Formalin-Fixed Paraffin-Embedded (FFPE) tissues following antigen retrieval, metal isotope-conjugated antibody staining, imaging using the MIBI instrument, and subsequent data processing and analysis. While this workflow is focused on imaging human FFPE samples using the MIBI, this workflow can be easily extended to model systems, biological questions, and multiplexed imaging modalities.


Subject(s)
Paraffin Embedding , Humans , Paraffin Embedding/methods , Spectrometry, Mass, Secondary Ion/methods , Tissue Fixation/methods , Image Processing, Computer-Assisted/methods , Formaldehyde/chemistry
7.
Hemodial Int ; 28(3): 382-386, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38571365

ABSTRACT

This article report a 40-year-old male patient who underwent total thyroidectomy and forearm auto-transplantation in another hospital for secondary hyperparathyroidism. After 4 years of follow-up, the level of parathyroid hormone continued to increase, and ultrasound showed nodules in the neck and right forearm, which were considered to be of parathyroid origin. Technetium 99m sestamibi single photon emission computed tomography and computed tomography (Tc-99m-MIBI SPECT/CT) imaging showed increased radioactive uptake in the submuscular soft tissue nodule of the right medial forearm, maximum standardized uptake value (SUVmax) is 0.98, which was identified as transplanted functioning parathyroid tissue. No parathyroid imaging activity was found in the neck. The patient then underwent partial removal of ectopic parathyroid tissue from the right forearm. Pathological examination confirmed parathyroid tissue, and removal was followed by a rapid decline in serum parathyroid hormone levels.


Subject(s)
Forearm , Hyperparathyroidism, Secondary , Parathyroid Glands , Technetium Tc 99m Sestamibi , Humans , Male , Adult , Hyperparathyroidism, Secondary/etiology , Hyperparathyroidism, Secondary/surgery , Parathyroid Glands/diagnostic imaging , Single Photon Emission Computed Tomography Computed Tomography/methods , Tomography, Emission-Computed, Single-Photon/methods
8.
Rev. ORL (Salamanca) ; 15(1)25-03-2024. tab, graf
Article in English | IBECS | ID: ibc-231859

ABSTRACT

Introduction: The location of the pathological parathyroid glands in hyperparathyroidism is usually carried out by means of 99mTc-sestamibi scintigraphy, which increases its precision by adding the ultrasound examination. The non-localization of the parathyroid glands increases the difficulties for surgical removal. To increase the detection of pathological glands, other radioactive tracers are used, such as methionine, fluorocholine or 18F-flurpiridaz. Objective: To establish if PET / CT with 18-Fluorocholine in patients with hyperparathyroidism increases the number of uptakes compared to the 99mTc-sestamibi scan. Method: Systematic review and meta-analysis. Two subgroups were analyzed. Subgroup 1: trials comparing both techniques as an initial exploration. Thirteen studies including 1131 examinations were selected (596 PET / CT with 18-Fluorocholine vs. 535 scintigraphy with 99mTc-sestamibi). Meta-analysis was performed following the random effects model and the odds ratio was calculated. Subgroup 2: studies that include 18-Fluorocholine as a rescue examination in patients with a previous negative study with a 99mTc-sestamibi scan. 17 articles including 412 examinations with 359 patients in which there was at least one uptake were selected. Meta-analysis of the prevalence of the number of patients in whom there was at least one uptake was performed using the random effects model. Results: Subgroup 1: The number of patients in which at least one uptake occurs is significantly higher with the 18-Fluorocholine examinations (OR 4.264, 95% CI 2.400-7.577). The prevalence of uptake with 18-Fluorocholine is 0.91 [0.86, 0.95] and with sestamibi 0.68 [0.56, 0.80]. Subgroup 2: the prevalence of uptake among patients with previous negative MIBI studies was 0.90 [0.87, 0.94]. The probability of detection of both techniques in this group reaches 0.98. Publication bias in the meta-analyzes is low. ... (AU)


Introducción: La localización de las glándulas paratiroides patológicas en el hiperparatiroidismo usualmente se realiza mediante gammagrafía con 99mTc-sestamibi que incrementa su precisión al añadir la exploración ecográfica. La no localización de las glándulas paratiroides incrementa las dificultades para la extirpación quirúrgica. Para incrementar la detección de glándulas patológicas se utilizan otros trazadores radiactivos como la metionina, la fluorocolina o el 18F-flurpiridaz.Objetivo: Establecer si el PET/TC con 18-Fluorocolina en pacientes con hiperparatiroidismo incrementa el número captaciones comparada con la gammagrafía con 99mTc-sestamibi.Método: Revisión sistemática y metanálisis. Se analizaron dos subgrupos. Subgrupo 1: ensayos que comparan ambas técnicas como exploración inicial. Se seleccionaron 13 estudios que incluyen 1131 exploraciones (596 PET/TC con 18-Fluorocolina vs. 535 gammagrafía con 99mTc-sestamibi). Se realizó metanálisis siguiendo el modelo de efectos aleatorios y se calculó la odds ratio. Subgrupo 2: estudios que incluyen la 18-Fluorocolina como exploración de rescate en pacientes con estudio previo negativo con gammagrafía con 99mTc-sestamibi. Se seleccionaron 17 artículos que incluyen 412 exploraciones con 359 pacientes en los que al menos hubo una captación. Se realizó metanálisis de la prevalencia del número de pacientes en los que hubo al menos una captación aplicando el modelo de efectos aleatorios.Resultados: Subgrupo 1: El número de pacientes en los que se presenta al menos una captación es significativamente superior con las exploraciones con 18-Fluorocolina (OR 4.264, IC 95% 2.400-7.577). La prevalencia de captaciones con 18-Fluorocolina es de 0.91 [0.86, 0.95] y con sestamibi de 0.68 [0.56, 0.80]. Subgrupo 2: la prevalencia de captaciones entre pacientes con estudios MIBI negativos previos fue de 0.90 [0.87, 0.94]. ... (AU)


Subject(s)
Humans , Hyperparathyroidism/drug therapy , Radionuclide Imaging , Parathyroid Diseases , Choline
9.
J Cancer ; 15(7): 1863-1869, 2024.
Article in English | MEDLINE | ID: mdl-38434973

ABSTRACT

Objective: To compare the diagnostic efficacy of 11C-choline PET/CT, neck ultrasonography, 99mTc-MIBI dual-phase planar scintigraphy, and 99mTc-MIBI SPECT/CT imaging in the diagnosis of primary hyperparathyroidism (PHPT). Methods: We conducted a retrospective analysis of 32 patients with PHPT who visited the Nuclear Medicine Department of Jilin University China-Japan Union Hospital between January 2019 and December 2022. All patients underwent 11C-choline PET/CT, neck ultrasonography, 99mTc-MIBI dual-phase planar scintigraphy, and 99mTc-MIBI SPECT/CT examinations within two months before surgery. Sensitivity, specificity, positive predictive value, and negative predictive value of each imaging study were compared using postoperative pathology and follow-up results. Diagnostic efficacy was further analyzed using ROC curve analysis. Factors influencing on 99mTc-MIBI imaging were also investigated. Results: A total of 35 lesions were resected in the 32 patients. The diagnostic sensitivity of 11C-choline PET/CT, neck ultrasonography, 99mTc-MIBI dual-phase planar scintigraphy, and 99mTc-MIBI SPECT/CT was 88.2%, 52.9%, 58.8%, and 67.6%, respectively. Specificity was 96.8%, 95.7%, 96.8%, and 95.7%, respectively. Positive predictive values were 90.9%, 81.8%, 86.9%, and 85.2%, respectively, and negative predictive values were 95.7%, 84.9%, 86.7%, and 89.1%, respectively. The areas under the ROC curve (AUC) were 0.925, 0.743, 0.778, and 0.817, respectively. Among them, 11C-choline PET/CT had higher sensitivity and AUC than other imaging studies (p<0.05), while specificity, positive predictive value, and negative predictive value were similar (p>0.05). The positive group in 99mTc-MIBI SPECT/CT imaging had significantly larger lesion diameters than the negative group (P<0.05), while preoperative blood calcium and PTH showed no statistical differences (P>0.05). Conclusion: 11C-choline PET/CT demonstrates superior preoperative diagnostic efficacy for PHPT compared to neck ultrasonography, 99mTc-MIBI dual-phase planar scintigraphy, and 99mTc-MIBI SPECT/CT. Lesion size may be the primary factor affecting the sensitivity of 99mTc-MIBI imaging.

10.
J Proteome Res ; 23(4): 1131-1143, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38417823

ABSTRACT

Multiplex imaging platforms have enabled the identification of the spatial organization of different types of cells in complex tissue or the tumor microenvironment. Exploring the potential variations in the spatial co-occurrence or colocalization of different cell types across distinct tissue or disease classes can provide significant pathological insights, paving the way for intervention strategies. However, the existing methods in this context either rely on stringent statistical assumptions or suffer from a lack of generalizability. We present a highly powerful method to study differential spatial co-occurrence of cell types across multiple tissue or disease groups, based on the theories of the Poisson point process and functional analysis of variance. Notably, the method accommodates multiple images per subject and addresses the problem of missing tissue regions, commonly encountered due to data-collection complexities. We demonstrate the superior statistical power and robustness of the method in comparison with existing approaches through realistic simulation studies. Furthermore, we apply the method to three real data sets on different diseases collected using different imaging platforms. In particular, one of these data sets reveals novel insights into the spatial characteristics of various types of colorectal adenoma.


Subject(s)
Computer Simulation , Analysis of Variance
11.
Gland Surg ; 13(1): 32-44, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38323231

ABSTRACT

Background: Functional parathyroid cysts (FPCs) are rare and difficult to diagnose with noninvasive methods. The aim of this study was to evaluate the diagnostic value of 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) single-photon emission computed tomography/computerized tomography (SPECT/CT) parathyroid imaging in the diagnosis of FPCs and to account for its performance. Methods: The data from 10 patients with suspected parathyroid cysts (PCs) who underwent 99mTc-MIBI SPECT/CT parathyroid imaging between 2012 and 2022 were retrospectively evaluated. The diagnostic value of 99mTc-MIBI SPECT/CT parathyroid imaging for FPCs was analyzed. Results: Surgical resection was performed in six cases and parathyroid puncture was performed in four cases. The sensitivity of 99mTc-MIBI SPECT/CT for FPCs was 100.0% (3/3), with a specificity of 100.0% (7/7) and an accuracy of 100.0% (10/10). The postoperative pathological findings in three cases of FPCs were parathyroid adenoma, parathyroid adenoma with hemorrhage, and parathyroid adenoma with cystic degeneration, respectively. The diagnostic accuracy of ultrasound and CT for PCs was only 22.22% (2/9) and 25.0% (1/4), respectively, and neither modality could indicate whether the cysts were functional or not. Conclusions: 99mTc-MIBI parathyroid SPECT/CT imaging has a high value in the diagnosis of FPCs in patients with suspected PCs, and an intense ring-shaped accumulation of radioactivity in the cyst wall on 99mTc-MIBI imaging suggests that the patient may have FPCs.

12.
Indian J Nucl Med ; 38(3): 224-230, 2023.
Article in English | MEDLINE | ID: mdl-38046959

ABSTRACT

Introduction: The objective of this study was to compare 99mTc MIBI myocardial perfusion SPECT and Dobutamine Stress Echocardiography (DSE) in detecting viable myocardium in patients with Coronary Artery Disease. Materials and Methods: Total of 50 patients who with CAD and poor LV function were idenitifed on 2D Echo using 16 segment cardiac model. These patients underwent 99mTc MIBI myocardial perfusion SPECT and Dobutamine Stress Echocardiography and the results were compared with the gold standard 18F-FDG PET-CT findings. Results: A Total of 550 dysfunctional segments were identified in datasets of 50 patients on 2D echo. No significant difference was noted between the pairwise positive outcome of viable segment between MIBI SPECT and DSE (p=0.875). MIBI SPECT showed a sensitivity of 86.5% and specificity of 90.0% when compared with 18F-FDG PET-CT which was comparable with DSE having a sensitivity of 87.6% and specificity of 90.7%. Conclusion: 99mTc MIBI SPECT is an effective good alternative for evaluation of viable myocardial segments in patients with dysfunctional myocardium and can be considered especially in elderly or obese patients and patients with lung disease having poor echocardiographic imaging window due to lack of an optimal acoustic window.

13.
Quant Imaging Med Surg ; 13(12): 8669-8680, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38106262

ABSTRACT

Background: Exact preoperative localization is desirable to perform minimally invasive parathyroidectomy for hyperparathyroidism (HPT). This study aimed to evaluate the diagnostic values of 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) of parathyroid glands by analyzing the relationship between lesion weight and false-negative (FN) results, as well as to explain the possible reason. Methods: The data from 314 patients with suspected HPT who underwent 99mTc-MIBI SPECT/CT parathyroid imaging between 2011 and 2022 were retrospectively evaluated. The sensitivity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of parathyroid 99mTc-MIBI SPECT/CT were calculated, and the false-positive (FP) and FN findings were analyzed. Results: Accurate localization by 99mTc-MIBI SPECT/CT was significantly associated with the parathyroid hormone (PTH) level. The 99mTc-MIBI SPECT/CT for diagnosis/lesion location reached a sensitivity of 84.6%/56.8%, a PPV of 97.3%/98.4%, an NPV of only 23.7%/4.18%, and an accuracy of 83.4%/57.1%, respectively. The largest diameter, shortest diameter, and lesion volume were lower in the FN group than in the TP group. A total of 7 FP cases were found, including 2 cases of thyroid nodules, 4 cases of thyroid tissue, and 1 case of hibernoma. A total of 45 FN patients, including 321 FN lesions, were confirmed, of which parathyroid hyperplasia accounted for 97.8%. Lesion weights greater than 20 µg were able to be detected, but lightweight lesions less than 100 mg were the principal source of FN results, accounting for approximately 39.3%. With lesion weights 0-100, 101-300, 301-1,000, and >1,000 mg, the FN rate was 70.8% (126/178), 51.8% (103/199), 34.6% (81/234), and 8.33% (11/132), respectively. Conclusions: 99mTc-MIBI SPECT/CT parathyroid imaging provides good sensitivity and high specificity in HPT location. Correct localization by 99mTc-MIBI SPECT/CT correlates positively with lesion weight and PTH levels. The smaller the lesion, the higher the FN rate in 99mTc-MIBI SPECT/CT parathyroid imaging, and lesions weighing less than 100 mg are the main source of FN results in 99mTc-MIBI SPECT/CT parathyroid imaging.

14.
Hum Vaccin Immunother ; 19(3): 2267295, 2023 12 15.
Article in English | MEDLINE | ID: mdl-37885158

ABSTRACT

In the field of immunology, a systems biology approach is crucial to understanding the immune response to infection and vaccination considering the complex interplay between genetic, epigenetic, and environmental factors. Significant progress has been made in understanding the innate immune response, including cell players and critical signaling pathways, but many questions remain unanswered, including how the innate immune response dictates host/pathogen responses and responses to vaccines. To complicate things further, it is becoming increasingly clear that the innate immune response is not a linear pathway but is formed from complex networks and interactions. To further our understanding of the crosstalk and complexities, systems-level analyses and expanded experimental technologies are now needed. In this review, we discuss the most recent immunoprofiling techniques and discuss systems approaches to studying the global innate immune landscape which will inform on the development of personalized medicine and innovative vaccine strategies.


Subject(s)
Vaccines , Immunity, Innate , Vaccination , Systems Biology
15.
Eur Heart J Case Rep ; 7(10): ytad470, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37841044

ABSTRACT

Background: Autologous myoblast patch (AMP) transplantation has resulted in good clinical outcomes for end-stage ischaemic cardiomyopathy, but the mechanisms behind them are unclear. Herein, we report the relationship between mitochondrial function and coronary flow reserve (CFR) before and after AMP transplantation. Case summary: The patient was a 73-year-old man who underwent coronary artery bypass grafting (CABG). At that time, the left ventricular ejection fraction (LVEF) was 53%, but it declined to 25% after 6 years. He was diagnosed with ischaemic cardiomyopathy (ICM). Coronary flow reserve in NH3-positron emission tomography (NH3-PET) was impaired to 1.69. In Tc-99m MIBI scintigraphy, the washout rate (WR) was 17%, suggestive of impaired mitochondrial function. He was not a candidate for heart transplantation, and we performed AMP transplantation 6 years after CABG. One year after AMP transplantation, LVEF, CFR, and Tc-99m MIBI WR improved to 36%, 2.07, and 7%, respectively. The Tc-99m MIBI WR improved especially in the anterolateral region, and the CFR increased in almost all segments. Discussion: In this case, AMP transplantation for ICM improved cardiac function, CFR, and mitochondrial function. The mitochondrial transfer from the transplanted myoblasts to the damaged myocardium may have contributed to the mitochondrial function improvement. This probably induced myocardial energy metabolism recovery and decreased oxygen demand. AMP transplantation also has the potential to improve microvascular dysfunction, due to angiogenesis induction. These effects can lead to improved prognoses of ICM after AMP transplantation, highlighting its potential to cure refractory heart failure.

16.
Environ Monit Assess ; 195(8): 970, 2023 Jul 19.
Article in English | MEDLINE | ID: mdl-37466699

ABSTRACT

River sediment is vital in containing water pollution and strengthening water remediation. This paper has conducted a study on the microecological health assessment of the sediment and water body of Guixi River in Dianjiang, Chongqing, China, using metagenomics sequencing and microbial biological integrity index (M-IBI) technology. The analysis of physical and chemical characteristics shows that the concentration of TN varies from 2.62 to 9.76 mg/L in each sampling section, and the eutrophication of the water body is relatively severe. The proportion of Cyanobacteria in the sampling section at the sink entrance is higher than that of other sites, where there are outbreaks of water blooms and potential hazards to human health. The dominant functions of each site include carbon metabolism, TCA cycle, and pyruvate metabolism. In addition, the main virulence factors and antibiotic resistance genes in sediment are Type IV pili (VF0082), LOS (CVF494), MymA operon (CVF649), and macrolide resistance genes macB, tetracyclic tetA (58), and novA. Correlation analysis of environmental factors and microorganisms was also performed, and it was discovered that Thiothrix and Acidovorax had obvious gene expression in the nitrogen metabolism pathway, and the Guixi River Basin had a self-purification capacity. Finally, based on the microecological composition of sediment and physical and chemical characteristics of the water body, the health assessment was carried out, indicating that the main pollution area was Dianjiang Middle School and the watershed near the sewage treatment plant. The findings should theoretically support an in-depth assessment of the water environment's microecological health.


Subject(s)
Environmental Monitoring , Metagenomics , Rivers , Water Pollutants, Chemical , China , Water Pollutants, Chemical/analysis , Drug Resistance, Bacterial , Genes, Bacterial , Humans
17.
Endocrinol Diabetes Nutr (Engl Ed) ; 70 Suppl 2: 35-44, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37268356

ABSTRACT

PURPOSE: Selective parathyroidectomy, the treatment of choice for primary hyperparathyroidism, requires precise preoperative localization. Our purpose was to compare the accuracy and concordance of pre-surgical MIBI parathyroid scintigraphy and ultrasonography, as well as to assess the relevance of hybrid acquisition (SPECT/CT) in compromised circumstances: low-weight or ectopic adenomas, coexisting thyroid disease and re-interventions. METHODS: The study included 223 patients with primary hyperparathyroidism operated in a single Surgical Unit from August 2016 to March 2021. Preoperative ultrasonography and double-phase MIBI were performed with early SPECT/CT acquisition. A minimally invasive surgical approach was initially attempted, except in patients with concomitant thyroid surgery or multiglandular parathyroid disease. RESULTS: Selective parathyroidectomy was accomplished in 179 patients (80.2%); cervicotomy and/or thoracoscopy in 44. Removal of the parathyroid lesion was achieved in 211 patients (94.6%), corresponding 204 (96.7%) to adenomas (37 ectopic). The cure rate was 94.2%. Preoperative MIBI SPECT/CT showed higher sensitivity and accuracy (84%; 80%) compared to ultrasound (72%; 71%), being more precise in defining the exact anatomical location (75.8% vs 68.7%). These differences reached statistical significance in ectopic glands. The existence of concomitant thyroid pathology did not decrease the sensitivity of SPECT/CT (84.2%). Mean parathyroid weight was 692.2mg (95%CI: 443.5-941) in MIBI-negative cases and 1145.9mg (95%CI: 983.6-1308.3) in MIBI-positive (p=0.001). Re-intervention was successful in the 8 patients with previous surgery. CONCLUSION: MIBI SPECT/CT presents greater sensitivity, accuracy and anatomical precision than ultrasound for preoperative parathyroid localization, even in the case of ectopic glands or coexisting thyroid pathology. The weight of the pathological gland is a significantly limiting factor.


Subject(s)
Adenoma , Hyperparathyroidism, Primary , Humans , Hyperparathyroidism, Primary/diagnostic imaging , Hyperparathyroidism, Primary/surgery , Technetium Tc 99m Sestamibi , Parathyroid Glands/diagnostic imaging , Parathyroid Glands/surgery , Single Photon Emission Computed Tomography Computed Tomography , Adenoma/surgery
18.
J Clin Med ; 12(12)2023 Jun 17.
Article in English | MEDLINE | ID: mdl-37373790

ABSTRACT

The purpose of the study was to assess the clinical, biochemical, and sonographic factors influencing the performance of parathormone washout measurement (PTHw) vs. MIBI in the preoperative localization of parathyroid adenoma (PA). The studied group consisted of 39 patients with primary or tertiary hyperparathyroidism. The measurement of PTH concentrations was performed using an electro-chemiluminescence immunoassay. Scintigraphic localization of PA was carried out using dual-tracer planar neck scintigraphy, using 74 MBq 99mTc-pertechnetate and 740 MBq of 99mTc-MIBI. MIBI was unambiguously positive in 74% of patients. Among patients with negative or inconclusive MIBI, 90% had a positive PTHw result. Among patients with negative PTHw, two out of three had a positive MIBI result. The PTHw of lesions <10 mm in their largest diameter yielded positive results in 95%, compared to 75% for MIBI. For lesions ≥10 mm in largest diameter, 88% were visualised using MIBI. In conclusion, PTHw is a highly effective, easy, quick, safe, and relatively cheap procedure which might be considered for PA localisation, especially in patients with lesions presenting typical ultrasound features and a size below 10 mm. MIBI remains a useful procedure in specialized centres, particularly for patients in whom PTHw failed, larger lesions, and in cases of the ectopic location of PA.

19.
Methods Mol Biol ; 2660: 171-185, 2023.
Article in English | MEDLINE | ID: mdl-37191797

ABSTRACT

Multiplex ion beam imaging (MIBI) and imaging mass cytometry (IMC) enable highly multiplexed antibody (40+) staining of frozen or formalin fixed, paraffin-embedded (FFPE) human or murine tissues through detection of metal ions liberated from primary antibodies by time-of-flight mass spectrometry (TOF). These methods make detection of more than 50 targets theoretically possible while maintaining spatial orientation. As such, they are ideal tools to identify the multiple immune, epithelial, and stromal cell subsets in the tumor microenvironment and to characterize spatial relationships and tumor-immune status in either murine models or human samples. This chapter summarizes methods for antibody conjugation and validation, staining, and preliminary data collection using IMC or MIBI in both human and mouse pancreatic adenocarcinoma samples. These protocols are intended to facilitate use of these complex platforms in not only tissue-based tumor immunology studies but also tissue-based oncology or immunology studies more broadly.


Subject(s)
Adenocarcinoma , Pancreatic Neoplasms , Mice , Humans , Animals , Tumor Microenvironment , Mass Spectrometry/methods , Diagnostic Imaging , Paraffin Embedding/methods , Formaldehyde/chemistry , Tissue Fixation/methods
20.
Cureus ; 15(4): e37635, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37200669

ABSTRACT

Hypercalcemia is a common electrolyte abnormality with different causes. Hypercalcemia is most often associated with malignancy and primary hyperparathyroidism and malignancy together account for most cases. Primary hyperparathyroidism manifests as hypercalcemia owing to the overproduction of parathyroid hormone. In most cases, primary hyperparathyroidism manifests due to a solitary parathyroid adenoma. Based on calcium levels, hypercalcemia can be classified as mild, moderate, and severe. Hypercalcemia typically presents with non-specific clinical features. Here, we present the case of a 38-year-old male patient who presented to the emergency department (ED) with acute abdominal pain and a tender abdomen with absent bowel sounds. He had chest radiography and blood tests initially. Chest radiography showed left-sided pneumoperitoneum, and the patient was suspected to have a perforated peptic ulcer due to hypercalcemia secondary to a parathyroid adenoma during the second wave of the coronavirus disease 2019 (COVID-19) pandemic. The findings were confirmed by a computerized tomography scan of the abdomen, and the patient was treated with intravenous fluids for hypercalcemia and was managed conservatively for a sealed perforated peptic ulcer following discussion in the multi-disciplinary team meeting (MDT). The COVID-19 pandemic led to a long waiting list and delays in the timely management of patients requiring elective surgical intervention, such as parathyroidectomy. The patient made a complete recovery and had parathyroidectomy of the inferior right lobe two months later.

SELECTION OF CITATIONS
SEARCH DETAIL
...