Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 68
Filter
1.
ISA Trans ; 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38918100

ABSTRACT

This paper proposes a distributed synchronization control method and an accelerated backstepping tracking control scheme for the multi-motor driving system (MMDS). In the first step, we create a dynamic model of the MMDS with complex nonlinear dynamics, encompassing elements such as the dead zone, frictions, and disturbances. Next, in order to tackle the challenge of load tracking, we fuse a speed function, a cosine barrier function, a second-order tracking differentiator (TD), and a disturbance compensator into the backstepping approach. Lastly, to address potential issues related to diverse torque inputs, which could result in the overload occurrences, we put forward a novel distributed synchronization control scheme. This scheme aims to achieve torque synchronization for the MMDS while simultaneously ensuring superior load tracking performance. In the distributed synchronization control, a communication network is built to achieve the local coupling and improve the synchronization efficiency, and a corresponding mean deviation coupling synchronization control scheme is designed. Lyapunov theory is utilized to demonstrate the stability of the introduced control scheme. The simulation experimental results for the MMDS show the effectiveness of the proposed scheme.

2.
Ophthalmol Glaucoma ; 7(4): 380-390, 2024.
Article in English | MEDLINE | ID: mdl-38636704

ABSTRACT

PURPOSE: To determine the associations between social vulnerability index (SVI) and baseline severity, worsening, and variability of glaucoma, as assessed by visual field (VF) and OCT. DESIGN: Retrospective longitudinal cohort study. PARTICIPANTS: Adults with glaucoma or glaucoma suspect status in 1 or both eyes. Visual fields were derived from 7897 eyes from 4482 patients, while OCTs were derived from 6271 eyes from 3976 patients. All eyes had a minimum of 5 tests over follow-up using either the Humphrey Field Analyzer or the Cirrus HD-OCT. METHODS: Social vulnerability index, which measures neighborhood-level environmental factors, was linked to patients' addresses at the census tract level. Rates of change in mean deviation (MD) and retinal nerve fiber layer (RNFL) thickness were computed using linear regression. The slope of the regression line was used to assess worsening, while the standard deviation of residuals was used as a measure of variability. Multivariable linear mixed-effects models were used to investigate the impact of SVI on baseline, worsening, and variability in both MD and RNFL. We further explored the interaction effect of mean intraocular pressure (IOP) and SVI on worsening in MD and RNFL. MAIN OUTCOME MEASURES: Glaucoma severity defined based on baseline MD and RNFL thickness. Worsening defined as MD and RNFL slope. Variability defined as the standard deviation of the residuals obtained from MD and RNFL slopes. RESULTS: Increased (worse) SVI was significantly associated with worse baseline MD (ß = -1.07 dB, 95% confidence interval [CI]: [-1.54, -0.60]), thicker baseline RNFL (ß = 2.46 µm, 95% CI: [0.75, 4.17]), greater rates of RNFL loss (ß = -0.12 µm, 95% CI: [-0.23, -0.02]), and greater VF variability (ß = 0.16 dB, 95% CI: [0.07, 0.24]). Having worse SVI was associated with worse RNFL loss with increases in IOP (ßinteraction = -0.07, 95% CI: [-0.12, -0.02]). CONCLUSIONS: Increased SVI score is associated with worse functional (VF) loss at baseline, higher rates of structural (OCT) worsening over time, higher VF variability, and a greater effect of IOP on RNFL loss. Further studies are needed to enhance our understanding of these relationships and establish their cause. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Subject(s)
Glaucoma , Intraocular Pressure , Nerve Fibers , Retinal Ganglion Cells , Severity of Illness Index , Tomography, Optical Coherence , Visual Fields , Humans , Male , Female , Visual Fields/physiology , Retrospective Studies , Intraocular Pressure/physiology , Tomography, Optical Coherence/methods , Retinal Ganglion Cells/pathology , Glaucoma/physiopathology , Glaucoma/diagnosis , Glaucoma/complications , Middle Aged , Nerve Fibers/pathology , Aged , Follow-Up Studies , Disease Progression , Visual Field Tests , Optic Disk/pathology
3.
Ophthalmology ; 130(11): 1138-1148, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37385298

ABSTRACT

PURPOSE: Frontloading SITA-Faster (SFR) visual fields (2 tests per eye on the same visit) has been shown to provide repeatable perimetric data at minimal time cost. This study reports the outcomes of using frontloaded SFR in the evaluation of pointwise visual field (VF) defects in a cohort of patients with glaucoma when transitioned from SITA-Standard (SS). DESIGN: Prospective, cross-sectional study. PARTICIPANTS: A total of 144 eyes of 91 patients with confirmed or suspected glaucoma who had an SS test on a previous visit. METHODS: Two SFR tests (T1, T2) per eye on the same visit. MAIN OUTCOME MEASURES: Global sensitivity, reliability indices, and pointwise deviation map probability scores from the pattern deviation grid of each patient were compared across the 3 sequential tests to evaluate the consistency of VF defects. RESULTS: The mean age was 68.6 years, and 79.2% of patients had a diagnosis of glaucoma. There was no significant difference in mean deviation (MD) across the 3 tests (-5.83 decibels [dB], -5.28 dB, and -5.71 dB in SS, SFR1, and SFR2, respectively, repeated-measures analysis of variance [ANOVA], P = 0.48). The frontloaded SFR tests provided repeatable VFs that confirmed existing pointwise data on the SS in 4661 (62.3%) locations, reversed an SS defect in 614 (8.2%) locations, and demonstrated a new repeatable defect in 406 (5.4%) locations of the pattern deviation grid. A new defect of at least 3 contiguous points was identified in 20.1% of eyes. The non-repeatable points on the 2 SFR tests displayed no significant difference in the distribution of defect/nondefect points based on test order or peripheral versus central locations. There was no significant difference in the rate of obtaining at least 1 reliable test result between SS and the frontloaded SFR T1 and T2 (P = 0.77). Test duration significantly decreased from SS to SFR1/2 (379 vs. 160 vs. 158 seconds, P < 0.0001). CONCLUSIONS: Frontloading SFR tests can provide repeatable data for the evaluation of the consistency of pattern deviation defects in glaucoma, with no observable decline in performance from test fatigue. This is achieved at equivalent duration and reliability as a single SS test. Frontloading SFR may be helpful in increasing testing frequency/quantity to meet recommended guidelines for progression analysis. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

4.
Cureus ; 15(3): e36981, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37139289

ABSTRACT

Purpose The purpose of the study is to assess whether standard automated perimetry (SAP) was capable of detecting early neuroretinal changes by comparing foveal sensitivity in diabetic and non-diabetic subjects. Settings and design This is an observational and cross-sectional study that compared foveal sensitivity between a case group of 47 subjects with no or mild-to-moderate diabetic retinopathy (DR) without maculopathy and a control group of 43 healthy subjects. Materials and Methods After a thorough ocular examination, all patients were put through tests using a Humphrey visual field analyzer with the Swedish interactive threshold algorithm (SITA) standard system (10-2 software). The primary indicator of success was the age-adjusted foveal awareness-esteem difference. Mean deviation (MD) and pattern standard deviation (PSD) readings were the supplementary performance indicators. Results The mean age of the case and control group was 50.76 ± 13.20 years and 49.90 ± 12.20 years, respectively. The probability of cataract development was higher in the case group (p < 0.0001). In the control group, 95.3% had best-corrected visual acuity (BCVA) in the category of good visual acuity (VA) (p < 0.0001). The mean foveal sensitivity in the case group was 28.57 ± 7.54 and 32.16 ± 7.09 for the control group, and the difference was statistically significant (p < 0.023). The mean of MD in the case group was -6.05 ± 7.93, whereas in the control group, it was -3.28 ± 1.70, which was found significant (p = 0.027). There was no difference in PSD between the study groups. Conclusions Foveal sensitivity decreased in diabetics, even without maculopathy, so SAP helps identify a patient at risk of future vision loss.

5.
Ophthalmol Glaucoma ; 6(5): 445-456, 2023.
Article in English | MEDLINE | ID: mdl-36958625

ABSTRACT

PURPOSE: To report the outcomes of frontloaded visual field (VF) testing (2 tests per eye on the same visit) over 2 longitudinal, consecutive visits using SITA-Faster (SFR) in terms of global indices, reliability metrics, and test duration. DESIGN: Prospective longitudinal study. SUBJECTS: A total of 902 eyes of 463 subjects with normal, suspect, or manifest glaucoma. METHODS: Two intravisit SFR VF tests (T1 and T2) per eye at an initial (Ti) and follow-up (Tf) visit. MAIN OUTCOME MEASURES: Intra- and intervisit global indices, reliability metrics, and test durations. RESULTS: The mean age of the subjects was 63.6 years, and 58.3% were male. Seven hundred ninety eyes (87.4%) had a diagnosis of glaucoma or glaucoma suspicion. The mean duration between visits was 265.0 (standard deviation 98.8) days. In total, 3608 VF tests were analyzed, with the correlation of mean deviation (MD) values of the frontloaded tests at each visit high (T1/T2 MD correlation at initial visit r = 0.83, root mean squared error [RMSE] = 1.26, follow-up visit r = 0.83, RMSE = 1.25, P < 0.0001) and greater than the correlation of MD between visits (Ti1/Tf1 MD correlation r = 0.72, RMSE = 1.31). There was a significant intra-visit decrease in rates of abnormally high sensitivity in the glaucoma hemifield test (3.2% vs. 1.6%, P = 0.0023) and rates of unreliable test results (15.4% vs. 9.2%, P = 0.002) from T1 to T2 in both visits, with a corresponding significant decrease in MD (-1.28 dB vs. -1.68 dB, P < 0.0001) and VF index (P = 0.03). The mean duration of each SFR test was 132.6 (SD 27.2) seconds. CONCLUSIONS: Frontloading VFs using SFR produced sets of repeatable perimetric data with significant improvement of reliability indices from the first to second test. This may help increase testing frequency at minimal time cost to meet recommended guidelines and for evaluating patients prone to high variability. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Subject(s)
Glaucoma , Visual Fields , Humans , Male , Middle Aged , Female , Prospective Studies , Reproducibility of Results , Longitudinal Studies , Vision Disorders/diagnosis , Visual Field Tests/methods , Glaucoma/diagnosis
6.
Ophthalmol Sci ; 3(2): 100264, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36846107

ABSTRACT

Purpose: To evaluate diagnostic precision and prove equivalence of 2 devices, Advanced vision analyzer (AVA, Elisar Vision Technology) and Humphrey field analyzer (HFA, Zeiss) for the detection of glaucoma on 10-2 program. Design: Prospective, cross-sectional, observational study. Participants: Threshold estimates of 1 eye each of 66 patients with glaucoma, 36 control participants, and 10 glaucoma suspects were analyzed on 10-2 test with AVA and HFA. Methods: Mean sensitivity (MS) values of 68 points and central 16 test points were calculated and compared. Intraclass correlation (ICC), Bland-Altman (BA) plots, linear regression of MS, mean deviation (MD), and pattern standard deviation (PSD) were computed to assess the 10-2 threshold estimate of the devices. Receiver operating characteristic curves were generated for MS and MD values, and the area under the curve (AUC) was compared with assessing diagnostic precision. Main Outcome Measures: Mean sensitivity values of 68 points and central 16 points, AUC for MS and MD values, ICC values, BA plots, and linear-regression analysis. Results: Bland-Altman plot showed significant correlation for MS, MD, and PSD values for both devices. For MS, the overall ICC value was 0.96 (P < 0.001) with a mean bias of 0.0 dB and limits of agreement range of 7.59. The difference in MS values between both devices was -0.4760 ± 1.95 (P > 0.05). The AUC for MS values for AVA was 0.89 and for HFA was 0.92 (P = 0.188); whereas it was similar at 0.88 for MD values (P = 0.799). Advanced vision analyzer and HFA identically discriminated between healthy and patients with glaucoma (P < 0.001), although HFA denoted marginally greater ability (P > 0.05). Conclusions: Statistical results denote adequate equivalence between AVA and HFA because threshold estimates of AVA strongly correlate with HFA for 10-2 program. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

7.
Eur J Health Econ ; 24(1): 5-25, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35278161

ABSTRACT

This paper introduces a new graphical tool: the mean deviation concentration curve. Using a unified approach, we derive the associated dominance conditions that identify robust rankings of absolute socioeconomic health inequality for all indices obeying Bleichrodt and van Doorslaer's (J Health Econ 25:945-957, 2006) principle of income-related health transfer. We also derive dominance conditions that are compatible with other transfer principles available in the literature. To make the identification of all robust orderings implementable using survey data, we discuss statistical inference for these dominance tests. To illustrate the empirical relevance of the proposed approach, we compare joint distributions of income and health-related behavior in the United States.


Subject(s)
Health Status Disparities , Income , Humans , United States , Socioeconomic Factors
8.
Ophthalmol Sci ; 3(1): 100222, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36325476

ABSTRACT

Purpose: Two novel deep learning methods using a convolutional neural network (CNN) and a recurrent neural network (RNN) have recently been developed to forecast future visual fields (VFs). Although the original evaluations of these models focused on overall accuracy, it was not assessed whether they can accurately identify patients with progressive glaucomatous vision loss to aid clinicians in preventing further decline. We evaluated these 2 prediction models for potential biases in overestimating or underestimating VF changes over time. Design: Retrospective observational cohort study. Participants: All available and reliable Swedish Interactive Thresholding Algorithm Standard 24-2 VFs from Massachusetts Eye and Ear Glaucoma Service collected between 1999 and 2020 were extracted. Because of the methods' respective needs, the CNN data set included 54 373 samples from 7472 patients, and the RNN data set included 24 430 samples from 1809 patients. Methods: The CNN and RNN methods were reimplemented. A fivefold cross-validation procedure was performed on each model, and pointwise mean absolute error (PMAE) was used to measure prediction accuracy. Test data were stratified into categories based on the severity of VF progression to investigate the models' performances on predicting worsening cases. The models were additionally compared with a no-change model that uses the baseline VF (for the CNN) and the last-observed VF (for the RNN) for its prediction. Main Outcome Measures: PMAE in predictions. Results: The overall PMAE 95% confidence intervals were 2.21 to 2.24 decibels (dB) for the CNN and 2.56 to 2.61 dB for the RNN, which were close to the original studies' reported values. However, both models exhibited large errors in identifying patients with worsening VFs and often failed to outperform the no-change model. Pointwise mean absolute error values were higher in patients with greater changes in mean sensitivity (for the CNN) and mean total deviation (for the RNN) between baseline and follow-up VFs. Conclusions: Although our evaluation confirms the low overall PMAEs reported in the original studies, our findings also reveal that both models severely underpredict worsening of VF loss. Because the accurate detection and projection of glaucomatous VF decline is crucial in ophthalmic clinical practice, we recommend that this consideration is explicitly taken into account when developing and evaluating future deep learning models.

9.
Ophthalmology ; 130(5): 469-477, 2023 05.
Article in English | MEDLINE | ID: mdl-36574847

ABSTRACT

PURPOSE: To investigate whether rates of standard automated perimetry (SAP) mean deviation (MD) over an initial 2-year follow-up period were predictive of events of visual field progression over an extended follow-up. DESIGN: Longitudinal, prospective, observational study. PARTICIPANTS: Two hundred forty-six eyes of 168 patients with glaucoma followed up every 6 months for up to 5 years. METHODS: Patients were required to have a minimum of 5 reliable SAP tests during the first 2 years of follow-up. Events of progression were evaluated using 2 methods: Guided Progression Analysis (GPA; Carl Zeiss Meditec, Inc) and a United States Food and Drug Administration (FDA)-suggested end point. The date of the first test showing progression after the first 2 years was considered to be the event date. Rates of change in SAP MD were calculated for the first 2 years of follow-up, and joint longitudinal survival models were used to assess the risk of faster initial MD loss for subsequent progression based on each event analysis. MAIN OUTCOME MEASURE: Risk of having an event of progression based on initial rates of SAP MD change. RESULTS: Fifty-six eye (22.8%) showed an event of progression by the GPA and 51 eyes (20.7%) did so by the FDA end point. Each 0.1-dB/year faster rate of SAP MD loss in the first 2 years was associated with a 26% increase in risk of a GPA progression end point developing (R2 = 76%) and 32% risk of an FDA-based end point developing (R2 = 83%). A reduction of 30% in the rate of MD change in the first 2 years was associated with a 20% reduction in the cumulative probability of a progression event developing over 5 years of follow-up. CONCLUSIONS: Rates of SAP MD change for eyes with glaucoma calculated over the initial 2 years of follow-up were strongly predictive of events of progression over subsequent follow-up. Our findings give support for the use of slopes of MD change as suitable end points of progression in clinical trials. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Subject(s)
Glaucoma , Intraocular Pressure , Humans , Prospective Studies , Vision Disorders/diagnosis , Glaucoma/diagnosis , Visual Field Tests , Disease Progression , Follow-Up Studies
10.
J Evol Biol ; 36(2): 347-354, 2023 02.
Article in English | MEDLINE | ID: mdl-36357964

ABSTRACT

Unequal breeding sex ratio can significantly reduce effective population size, allowing a rare neutral allele to jump to a high frequency through genetic drift. However, this one-way alteration to allele frequency appears inconsistent with the concept that drift is non-directional. Based on binomial sampling distribution, this study developed a method to directly and exhaustively measure drift by calculating the mean deviation of change in allele frequency, then applied it to cases of unequal breeding sex ratio. The result shows that, under those cases, (1) the mean deviation can always be divided into two halves that are equal in size but opposite in direction; (2) each half consists of one or several categories represented by various allele proportions in the rare sex; (3) this proportion is another factor that determines the outcome of drift, in addition to effective population size and allele frequency; (4) drift is non-directional on a global scale, but whether an allele will drift up or down can be predicted based on the above factors. This method enables us to dissect every component of the expected change in allele frequency caused by drift and to find out the combined effect of population size, allele frequency and allele proportion in the rarer sex under neutrality but unequal breeding sex ratio.


Subject(s)
Genetic Drift , Sex Ratio , Gene Frequency , Models, Genetic , Genetics, Population
11.
BMC Med Genomics ; 15(1): 272, 2022 12 28.
Article in English | MEDLINE | ID: mdl-36577966

ABSTRACT

Nasopharyngeal carcinoma (NPC) has insidious onset, late clinical diagnosis and high recurrence rate, which leads to poor quality of patient life. Therefore, it is necessary to further explore the pathogenesis and therapy targets of NPC. BUB1 mitotic checkpoint serine/threonine kinase B (BUB1B) was found to be up-regulated in a variety of cancers, but only two previous study showed that BUB1B was overexpressed in NPC and the sample size was small. The clinical role of BUB1B expression and its underlying mechanism in NPC require more in-depth research. Immunohistochemical samples and public RNA-seq data indicated that BUB1B protein and mRNA expression levels were up-regulated in NPC, and summary receiver operating characteristic curve indicated that BUB1B expression level had a strong ability to distinguish NPC tissues from non-NPC tissues. Gene ontology and Kyoto Encyclopedia of genes and genomes were performed and revealed that BUB1B and its related genes were mainly involved in cell cycle and DNA replication. Protein- Protein Interaction were built to interpret the BUB1B molecular mechanism. Histone deacetylase 2 (HDAC2) could be the upstream regulation factor of BUB1B, which was verified by Chromatin Immunoprecipitation Sequencing samples. In summary, BUB1B was highly expressed in NPC, and HDAC2 may affect cell cycle by regulating BUB1B to promote cancer progression.


Subject(s)
Nasopharyngeal Neoplasms , Protein Serine-Threonine Kinases , Humans , Nasopharyngeal Carcinoma/genetics , Up-Regulation , Protein Serine-Threonine Kinases/genetics , Cell Cycle/genetics , Nasopharyngeal Neoplasms/genetics , Nasopharyngeal Neoplasms/metabolism , Nasopharyngeal Neoplasms/pathology , Gene Expression Regulation, Neoplastic , Cell Cycle Proteins/genetics
12.
Ophthalmol Sci ; 2(2): 100120, 2022 Jun.
Article in English | MEDLINE | ID: mdl-36249704

ABSTRACT

Purpose: To investigate the effects of adjusting the ocular magnification during OCT-based angiography imaging on structure-function relationships and glaucoma detection. Design: Cross-sectional study. Participants: A total of 96 healthy control participants and 90 patients with open-angle glaucoma were included. Methods: One eye of each patient in the control group and the patient group was evaluated. The layers comprising the macula vascular density (VD) and circumpapillary VD were derived from swept-source OCT angiography imaging. The mean sensitivity (MS) of the standard automated perimetry was measured using the Humphrey 24-2 test. Structure-function relationships were evaluated with simple and partial correlation coefficients. A receiver operating characteristic analysis was performed to evaluate the diagnostic accuracy for glaucoma using the area under the receiver operating characteristic curve (AUC). Ocular magnification was adjusted using Littmann's formula modified by Bennett. Main Outcome Measures: The association between the axial length and VD, structure-function relationships, and glaucoma detection with and without magnification correction. Results: The superficial layer of the macular region was not significantly correlated to the axial length without magnification correction (r = 0.0011; P = 0.99); however, it was negatively correlated to the axial length with magnification correction (r = -0.22; P = 0.028). Regarding the nerve head layer in the circumpapillary region, a negative correlation to the axial length without magnification correction was observed (r = -0.22; P = 0.031); however, this significant correlation disappeared with magnification correction. The superficial layer of the macula and the nerve head layer of the circumpapillary region were significantly correlated to Humphrey 24-2 MS values without magnification correction (r = 0.22 and r = 0.32, respectively); however, these correlations did not improve after magnification correction (r = 0.20 and r = 0.33, respectively). Glaucoma diagnostic accuracy in the superficial layer (AUC, 0.63) and nerve head layer (AUC, 0.70) without magnification correction did not improve after magnification correction (AUC, 0.62 and 0.69, respectively). Conclusions: Adjustment of the ocular magnification is important for accurate VD measurements; however, it may not significantly impact structure-function relationships and glaucoma detection.

13.
Ophthalmol Sci ; 2(3): 100172, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36245753

ABSTRACT

Purpose: The purpose of the study was to compare a novel, 24°, 52-locus online circular contrast perimetry (OCCP) application against standard automated perimetry (SAP) in terms of both diagnostic accuracy and patient attitudes. Design: This was a cross-sectional study. Subjects: Ninety-five participants (42 controls and 53 open-angle glaucoma patients) were included. Methods: Participants performed both perimetry tests and then completed an online survey. Subjective feedback responses were collected. Main Outcome Measures: Agreement, sensitivity, specificity, and area under receiver operating curves (AUCs) were compared for the parameters of OCCP, SAP, and OCT for the retinal nerve fiber layer (RNFL) and macular ganglion cell complex inner plexiform layer (GCC + IPL). Participant attitudes toward the OCCP test versus the SAP test, in both glaucoma patients and controls, were compared. Rasch analysis assessed the psychometric properties of the survey and intergroup variability. Results: The AUC for OCCP mean deviation (MD) was 0.959 ± 0.02. Compared with other instruments' parameters with the highest AUC, it was superior to SAP MD (0.871 ± 0.04, P = 0.03) and OCT GCC + IPL (0.871 ± 0.04, P = 0.03) and similar to OCT RNFL inferior thickness (IT) (0.917 ± 0.03, no significance). Online circular contrast perimetry pointwise sensitivity was less than SAP by 4.30 dB (95% confidence interval = 4.02-4.59); 95% limits of agreement ranged from -6.28 to -2.33 dB. At the best cutoff, the OCCP MD had a sensitivity of 98% and specificity of 85% for detecting glaucoma. Cohen's kappa demonstrated good agreement with SAP MD (0.69) and OCT RNFL IT (0.62) and moderate agreement with OCT GCC + IPL IT (0.57). Participants preferred OCCP across most survey parameters (P < 0.0001). Rasch analysis demonstrated no differential item functioning for clinical group, gender, or age. Conclusions: With similar diagnostic metrics to SAP, OCCP offers an improved user experience with the potential to increase the provision of care and improve disease surveillance outcomes.

14.
Ophthalmol Sci ; 2(3): 100161, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36245761

ABSTRACT

Purpose: To assess 3-dimensional surface shape patterns of the optic nerve head (ONH) and peripapillary retinal nerve fiber layer (RNFL) in glaucoma with unsupervised artificial intelligence (AI). Design: Retrospective study. Participants: Patients with OCT scans obtained between 2016 and 2020 from Massachusetts Eye and Ear. Methods: The first reliable Cirrus (Carl Zeiss Meditec, Inc) ONH OCT scans from each eye were selected. The ONH and RNFL surface shape was represented by the vertical positions of the inner limiting membrane (ILM) relative to the lowest ILM vertical position in each eye. Nonnegative matrix factorization was applied to determine the ONH and RNFL surface shape patterns, which then were correlated with OCT and visual field (VF) loss parameters and subsequent VF loss rate. We tested whether using ONH and RNFL surface shape patterns improved the prediction accuracy for associated VF loss and subsequent VF loss rates measured by adjusted r 2 and Bayesian information criterion (BIC) difference compared with using established OCT parameters alone. Main Outcome Measures: Optic nerve head and RNFL surface shape patterns and prediction of the associated VF loss and subsequent VF loss rates. Results: We determined 14 ONH and RNFL surface shape patterns using 9854 OCT scans from 5912 participants. Worse mean deviation (MD) was most correlated (r = 0.29 and r = 0.24, Pearson correlation; each P < 0.001) with lower coefficients of patterns 10 and 12 representing inferior and superior para-ONH nerve thinning, respectively. Worse MD was associated most with higher coefficients of patterns 5, 4, and 9 (r = -0.16, r = -0.13, and r = -0.13, respectively), representing higher peripheral ONH and RNFL surfaces. In addition to established ONH summary parameters and 12-clock-hour RNFL thickness, using ONH and RNFL surface patterns improved (BIC decrease: 182, 144, and 101, respectively; BIC decrease ≥ 6; strong model improvement) the prediction of accompanied MD (r 2 from 0.32 to 0.37), superior (r 2 from 0.27 to 0.31), and inferior (r 2 from 0.17 to 0.21) paracentral loss and improved (BIC decrease: 8 and 8, respectively) the prediction of subsequent VF MD loss rates (r 2 from 0 to 0.13) and inferior paracentral loss rates (r 2 from 0 to 0.16). Conclusions: The ONH and RNFL surface shape patterns quantified by unsupervised AI techniques improved the structure-function relationship and subsequent VF loss rate prediction.

15.
Ophthalmol Sci ; 2(1): 100097, 2022 Mar.
Article in English | MEDLINE | ID: mdl-36246178

ABSTRACT

Purpose: To assess whether the predictive accuracy of machine learning algorithms using Kalman filtering for forecasting future values of global indices on perimetry can be enhanced by adding global retinal nerve fiber layer (RNFL) data and whether model performance is influenced by the racial composition of the training and testing sets. Design: Retrospective, longitudinal cohort study. Participants: Patients with open-angle glaucoma (OAG) or glaucoma suspects enrolled in the African Descent and Glaucoma Evaluation Study or Diagnostic Innovation in Glaucoma Study. Methods: We developed a Kalman filter (KF) with tonometry and perimetry data (KF-TP) and another KF with tonometry, perimetry, and global RNFL data (KF-TPO), comparing these models with one another and with 2 linear regression (LR) models for predicting mean deviation (MD) and pattern standard deviation values 36 months into the future for patients with OAG and glaucoma suspects. We also compared KF model performance when trained on individuals of European and African descent and tested on patients of the same versus the other race. Main Outcome Measures: Predictive accuracy (percentage of MD values forecasted within the 95% repeatability interval) differences among the models. Results: Among 362 eligible patients, the mean ± standard deviation age at baseline was 71.3 ± 10.4 years; 196 patients (54.1%) were women; 202 patients (55.8%) were of European descent, and 139 (38.4%) were of African descent. Among patients with OAG (n = 296), the predictive accuracy for 36 months in the future was higher for the KF models (73.5% for KF-TP, 71.2% for KF-TPO) than for the LR models (57.5%, 58.0%). Predictive accuracy did not differ significantly between KF-TP and KF-TPO (P = 0.20). If the races of the training and testing set patients were aligned (versus nonaligned), the mean absolute prediction error of future MD improved 0.39 dB for KF-TP and 0.48 dB for KF-TPO. Conclusions: Adding global RNFL data to existing KFs minimally improved their predictive accuracy. Although KFs attained better predictive accuracy when the races of the training and testing sets were aligned, these improvements were modest. These findings will help to guide implementation of KFs in clinical practice.

16.
Ophthalmol Sci ; 2(1): 100105, 2022 Mar.
Article in English | MEDLINE | ID: mdl-36276927

ABSTRACT

Purpose: Vivid Vision Perimetry (VVP; Vivid Vision, Inc) is a novel method for performing in-office and home-based visual field assessment using a virtual reality platform and oculokinetic perimetry. Here we examine the reproducibility of VVP Swift and compare results with conventional standard automated perimetry (SAP) and spectral-domain (SD) OCT. Design: Cross-sectional study. Participants: Fourteen eyes of 7 patients with open-angle glaucoma (OAG) (average age, 64.6 years; 29% women) and 10 eyes of 5 patients with suspected glaucoma (average age, 61.8 years; 40% women) were enrolled. Methods: Patients with OAG and suspected glaucoma were enrolled prospectively and underwent 2 VVP Swift examinations. Results were compared with 1 conventional SAP examination (Humphrey Visual Field [HVF]; Zeiss) and 1 SD OCT examination. Main Outcome Measures: Mean sensitivity (in decibels) obtained for each eye in 2 VVP Swift test sessions and a conventional SAP examination, thickness of the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) for the SD OCT examination, and mean test durations of the VVP Swift and SAP examinations. Results: The mean test duration of VVP Swift in both eyes (8.5 minutes) was significantly shorter (P < 0.001) than SAP (12.2 minutes). The average absolute difference of the mean sensitivity between the 2 VVP Swift sessions was found to be 0.73 dB (95% confidence interval [CI], 0.40-1.06). A statistically significant association was found between average mean sensitivity measurements from the VVP and mean deviation (MD) measurements obtained by the HVF with a Pearson correlation coefficient of 0.86 (95% CI, 0.70-0.94; P < 0.001). Mean visual sensitivity measurements from the VVP Swift test were significantly associated with average RNFL thickness (r = 0.66; P = 0.014) and GCC thickness (r = 0.63; P = 0.02), whereas the correlation coefficients between HVF MD and RNFL and GCC were 0.86 (P < 0.001) and 0.83 (P < 0.001), respectively. Conclusions: Our results demonstrated that the VVP Swift test can generate reproducible results and is comparable with conventional SAP. This suggests that the device can be used by clinicians to assess visual function in glaucoma.

17.
Indian J Ophthalmol ; 70(8): 2895-2901, 2022 08.
Article in English | MEDLINE | ID: mdl-35918939

ABSTRACT

Purpose: To correlate and analyze the pattern of the visual field (VF) defects by perimetry and anterior chamber angle parameters by AS-OCT in primary angle-closure glaucoma (PACG) across varied severity levels on presentation to a tertiary eye care center. Methods: This was a cross-sectional study, which included 323 eyes of clinically diagnosed cases of PACG. Glaucoma severity was categorized according to mean deviation (MD) as mild (-6.00 dB or more), moderate (-6.01 to -12.00 dB), and severe (-12.01 to -30.00 dB). AS-OCT measured the nasal (N) and temporal (T) angle opening distance at 500 µm (AOD 500) and 750 µm (AOD 750), anterior chamber angle (ACA), lens vault (LV), and anterior chamber width (ACW). The VF severity was then correlated with the AS-OCT parameters using statistical analysis. Results: The mean age ± standard deviation (SD) of the patients included in the study was 56.03 ± 8.6 years, with a 1:1.2 gender ratio. The number of eyes with mild, moderate, and severe VFs were 140 (43.3%), 88 (27.24%), and 95 (29.41%), respectively. There was no statistically significant correlation in the mean anterior chamber angle parameters (AOD 500, AOD 750, ACA 500, ACA 750, LV, ACW, and axial length (AL)) among the groups. However, the correlation between AOD 500 and LV thickness was found to be significant (P = 0.0000) with a negative Spearman's rank correlation coefficient (r = -0.3329). Conclusion: The ACA parameters obtained by AS-OCT along the horizontal axis after elimination of pupillary block by laser peripheral iridotomy do not correlate and cannot be used to assess the disease severity of PACG.


Subject(s)
Glaucoma, Angle-Closure , Tomography, Optical Coherence , Anterior Chamber , Anterior Eye Segment/diagnostic imaging , Cross-Sectional Studies , Glaucoma, Angle-Closure/diagnosis , Gonioscopy , Humans , Intraocular Pressure , Iris , Tomography, Optical Coherence/methods , Vision Disorders , Visual Field Tests , Visual Fields
18.
Front Med (Lausanne) ; 9: 932232, 2022.
Article in English | MEDLINE | ID: mdl-35836955

ABSTRACT

Background: Evidence regarding the impact on visual field (VF), intraocular pressure (IOP), and antiglaucoma medications from trabeculectomy with antimetabolites for normal tension glaucoma (NTG) is conflicting because of insufficient study sample sizes. The aim of this study is to systematically assess VF progression rate, IOP control and antiglaucoma medication use after trabeculectomy with antimetabolites for progressing NTG. Methods: We searched published articles on PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials from database inception to March 21, 2022. We selected studies that reported VF data before and after trabeculectomy with antimetabolite agents for NTG. We followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses reporting guidelines. Data were extracted by 2 independent reviewers, and a random-effects model was employed for the meta-analysis. Study outcomes were VF progression rates measured using the pooled mean deviation (MD) slope, changes in antiglaucoma medications, and IOP. Subgroup analyses of the MD slope according to mean age (over or under 65 years), baseline MD (over or under -12 dB), and baseline IOP (over or under 15 mmHg) were performed to determine the results' robustness. Results: We included 7 retrospective observational studies (Japan: 6 studies, United States: 1 study) comprising a total of 166 eyes. Mean preoperative VF MD slopes ranged from -0.52 to -1.05 dB/year. The meta-analysis demonstrated significant MD slope improvement after trabeculectomy (pooled mean difference: 0.54 dB/year, 95% CI: 0.40 to 0.67, I2 = 9%). Mean age, baseline MD, and baseline IOP subgroup analyses revealed MD slope results were consistent with those of the main analyses. The mean IOP (pooled mean difference: -5.54 mmHg, 95% CI: -6.02 to -5.06, I2 = 0%) and mean number of antiglaucoma medications (pooled mean difference: -1.75, 95% CI: -2.97 to -0.53, I2 = 98%) significantly decreased after trabeculectomy. The most frequently reported early complications after trabeculectomy were hypotony, hyphema, and shallow anterior chamber. Conclusion: This systematic review and meta-analysis indicated that trabeculectomy with antimetabolites is beneficial for progressing NTG; it preserves visual function by alleviating the MD slope and reducing antiglaucoma medication use. However, several post-trabeculectomy complications should be monitored.

19.
Am J Ophthalmol ; 242: 69-76, 2022 10.
Article in English | MEDLINE | ID: mdl-35654121

ABSTRACT

PURPOSE: Investigate associations of race/ethnicity and preferred language with baseline glaucoma severity, VF test frequency and disease progression. DESIGN: Retrospective cohort study. METHODS: Patients receiving VF testing at a tertiary eyecare center between 1998 and 2020 with self-identified race, ethnicity and preferred language were included. Outcome measures were VF MD and age at first visit, VF test frequency, VF MD progression. RESULTS: Among 29,891 patients with VF measurements between 1998 and 2020, 55.1% were female, 71.0% self-identified as White/Caucasian, 14.0% as Black/African American, 7.4% as Asian and 6.4% as Hispanic, and 11.2% preferred a language other than English. Mean VF MD at presentation was worse among Black (-9.3±9.7 dB), Asian (-6.2±7.6 dB) and Hispanic (-8.3±9.3 dB) patients (vs. Whites [-5.5±7.3 dB, p<0.001] or non-Hispanics [-6.2±7.8 dB, p<0.001]). After controlling for age, gender and English proficiency, disparities in glaucoma severity at presentation were reduced, especially among Asian and Hispanic patients. Despite greater severity at presentation, Black patients had lower VF test frequency/person-years (1.07±0.53) compared to Whites (1.12±0.52, p=0.006) and worse VF MD progression (-0.43 dB/year, 95% CI -0.67 to -0.28, p<0.001). In contrast, Hispanics had a higher VF frequency vs. non-Hispanics (1.18±0.64 vs. 1.11±0.52, p<0.001), and no difference in VF progression (p=0.77). CONCLUSIONS: Black, Asian and Hispanic patients had greater baseline severity vs. Whites. Unlike other groups, Black patients had a lower VF frequency vs. Whites and greater VF progression. Disparities in baseline severity were partially explained by English proficiency, especially for Asian and Hispanic patients.


Subject(s)
Glaucoma , Visual Fields , Disease Progression , Ethnicity , Female , Glaucoma/diagnosis , Humans , Intraocular Pressure , Male , Retrospective Studies , Severity of Illness Index , Vision Disorders , Visual Field Tests
20.
BMC Ophthalmol ; 22(1): 151, 2022 Apr 02.
Article in English | MEDLINE | ID: mdl-35366841

ABSTRACT

BACKGROUND: This prospective comparative study aimed to investigate the influence of diffractive trifocal intraocular lenses (IOLs) implantation on standard automated perimetry. METHODS: Patients with no diseases affecting the visual field had undergone cataract surgery following the implantation of trifocal or monofocal IOLs from July 2019 to August 2020 were recruited. The normality of the anterior and posterior segments and absence of glaucomatous optic nerve cupping were confirmed preoperatively by slit-lamp examination. Standard automated perimetry was performed using Humphrey Visual Field 10-2 testing, 2-3 months after cataract surgery in only one eye per patient. The mean deviation (MD) and foveal sensitivity were compared between IOLs in eyes with acceptable reliability indices and best-corrected visual acuity of 20/25 or better. RESULTS: Among the 83 eyes of the 83 patients included, 39 and 29 eyes eligible for perimetry analysis had trifocal and monofocal IOLs, respectively. The mean MD and foveal sensitivity in eyes with trifocal IOLs were significantly lower than those in eyes with monofocal IOLs (P < 0.021), with mean differences of 0.77 and 1.01 dB, respectively. CONCLUSION: The comparison in nonglaucomatous eyes demonstrated that the influence of trifocal IOLs on standard automated perimetry was greater than that of monofocal IOLs.


Subject(s)
Lenses, Intraocular , Visual Field Tests , Humans , Lens Implantation, Intraocular , Prospective Studies , Prosthesis Design , Reproducibility of Results , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL
...