Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
Article in English | MEDLINE | ID: mdl-37580222

ABSTRACT

OBJECTIVE: To describe changes in pulmonary mechanics when changing from supine position (SP) to prone position (PP) in mechanically ventilated (MV) patients with Acute Respiratory Distress Syndrome (ARDS) due to severe COVID-19. DESIGN: Retrospective cohort. SETTING: Intensive Care Unit of the National Institute of Respiratory Diseases (Mexico City). PATIENTS: COVID-19 patients on MV due to ARDS, with criteria for PP. INTERVENTION: Measurement of pulmonary mechanics in patients on SP to PP, using esophageal manometry. MAIN VARIABLES OF INTEREST: Changes in lung and thoracic wall mechanics in SP and PP RESULTS: Nineteen patients were included. Changes during first prone positioning were reported. Reductions in lung stress (10.6 vs 7.7, p=0.02), lung strain (0.74 vs 0.57, p=0.02), lung elastance (p=0.01), chest wall elastance (p=0.003) and relation of respiratory system elastances (p=0.001) were observed between patients when changing from SP to PP. No differences were observed in driving pressure (p=0.19) and transpulmonary pressure during inspiration (p=0.70). CONCLUSIONS: Changes in pulmonary mechanics were observed when patients were comparing values of supine position with measurements obtained 24h after prone positioning. Esophageal pressure monitoring may facilitate ventilator management despite patient positioning.

2.
São Paulo; s.n; 2008. 69 p. graf, tab, ilus.
Thesis in Portuguese | LILACS | ID: lil-540853

ABSTRACT

Estudo clínico prospectivo, em 11 pacientes com SARA ou LPA, avaliando o comportamento regional da densidade do tecido pulmonar e do colapso alveolar ao longo dos três eixos do espaço. Foram realizadas tomografias seriadas, após manobra de recrutamento inicial e após níveis de PEEP progressivamente decrescentes. Regressão linear múltipla (R2=0.83) mostrou importante gradiente no eixo gravitacional (p<0.001) e não no sentido céfalo-caudal (p<0.001), nem da direita para a esquerda (p<0.05). Isto corrobora o conceito do pulmão líquido, em que a resultante das pressões exercidas pelo diafragma, estruturas mediastinais e derrames seria transmitida uniformemente pelo tecido pulmonar. Cada um destes níveis isogravitacionais tem uma pressão crítica de fechamento (Pclosing), que é maior do que a pressão superimposta calculada. PEEP tem um efeito homogeneizador sobre o parênquima pulmonar. Dentre os parâmetros clínicos estudados, Pflex mostrou a pior correlação com colapso pulmonar documentado enquanto PO2 e a complacência máxima se mostraram equivalentes.


A prospective clinical study performed on 11 patients with ARDS or ALI with the intention of studying the regional behavior of lung tissue density and alveolar collapse along the three spatial axes. An initial recruitment maneuver was followed by multiple semi-complete CT scans at descending levels of PEEP. Multiple linear regression (R2=0.83) showed a gravitational gradient of densities and collapse (p<0.001) and no cephalo-caudal (p<0.001) or right-toleft increase (p<0.05), corroborating the liquid-like behavior of the lung. Pressure exerted by mediastinal structures, chest wall and effusions is transmitted uniformly throughout the lung. PEEP has a homogenizing effect on lung parenchyma. Among commonly used clinical surrogates, Pflex showed the worst correlation with actual lung collapse, while arterial PO2 and compliance were equivalent.


Subject(s)
Humans , Male , Female , Adult , Positive-Pressure Respiration , Respiration, Artificial , Respiratory Distress Syndrome , Tomography, X-Ray Computed
3.
Rev. bras. ter. intensiva ; 19(2): 161-169, abr.-jun. 2007.
Article in Portuguese | LILACS | ID: lil-466811

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Em ventilação mecânica invasiva e não-invasiva, o conhecimento da fisiologia da mecânica respiratória, é imprescindível para tomada de decisões e no manuseio eficiente dos ventiladores modernos. A monitorização dos parâmetros da mecânica pulmonar é recomendada nos trabalhos de revisão e de pesquisas clínicas. O objetivo deste estudo foi rever os conceitos de mecânica pulmonar e os métodos utilizados para obtenção de medidas à beira do leito, enfatizando três parâmetros: resistência, complacência e PEEP intrínseca. MÉTODO: Foi realizada revisão bibliográfica através dos bancos de dados LILACS, MedLine e PubMed, no período de 1996 a 2006. RESULTADOS: Esta revisão abordou os parâmetros de resistência, complacência pulmonar e PEEP intrínseca como fundamentais na compreensão da insuficiência respiratória aguda e suporte ventilatório mecânico, principalmente na doença pulmonar obstrutiva crônica (DPOC) e na síndrome da angústia respiratória aguda (SARA). CONCLUSÕES: A monitorização da mecânica pulmonar em pacientes sob ventilação mecânica em unidade de terapia intensiva (UTI) pode fornecer dados relevantes e deve ser implementada de forma sistemática e racional.


BACKGROUND AND OBJECTIVES: In mechanical ventilation, invasive and noninvasive, the knowledge of respiratory mechanic physiology is indispensable to take decisions and into the efficient management of modern ventilators. Monitoring of pulmonary mechanic parameters is been recommended from all the review works and clinical research. The objective of this study was review concepts of pulmonary mechanic and the methods used to obtain measures in the bed side, preparing a rational sequence to obtain this data. METHODS: It was obtained bibliographic review through data bank LILACS, MedLine and PubMed, from the last ten years. RESULTS: This review approaches parameters of resistance, pulmonary compliance and intrinsic PEEP as primordial into comprehension of acute respiratory failure and mechanic ventilatory support, mainly in acute respiratory distress syndrome (ARDS) and in chronic obstructive pulmonary disease (COPD). CONCLUSIONS: Monitoring pulmonary mechanics in patients under mechanical ventilation in intensive care units gives relevant informations and should be implemented in a rational and systematic way.


Subject(s)
Lung Compliance , Monitoring, Physiologic , Positive-Pressure Respiration , Lung/physiology , Respiration, Artificial
4.
Rev. bras. ter. intensiva ; 19(2): 170-175, abr.-jun. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-466812

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A fisioterapia respiratória (FR) em pacientes submetidos a suporte ventilatório invasivo, atua diretamente no sistema ventilatório podendo alterar a mecânica pulmonar através da complacência pulmonar dinâmica (Cdyn) e da resistência do sistema respiratório (Rsr). Porém, as alterações descritas após a realização de FR permanecem controversas. O objetivo deste estudo foi avaliar as alterações da mecânica pulmonar em pacientes em ventilação mecânica invasiva (VMI). MÉTODO: Foi realizado estudo prospectivo e aleatório, controlado do tipo cruzado, incluindo pacientes com mais de 48 horas em VMI. Os protocolos de fisioterapia respiratória (PF) e de aspiração traqueal isolada (PA) foram aleatorizados para a ordem de aplicação, com intervalo de 24 horas entre eles. Dados da mecânica pulmonar e das variáveis cardiorrespiratórias foram coletados antes da aplicação do protocolo, imediatamente após; 30 minutos e 120 minutos após a aplicação dos protocolos. RESULTADOS: Doze pacientes completaram o estudo. A pneumonia foi a causa mais comum de insuficiência respiratória (IRpA). Não houve diferença estatisticamente significativa entre os grupos em relação à Cdyn, volume de ar corrente (VAC) e volume-minuto (VM). A Rsr diminuiu de forma significativa imediatamente após (de 10,4 ± 3 cmH2O/L/seg para 8,9 ± 2 cmH2O/L/seg; p < 0,02), 30 minutos após (de 10,4 ± 3 cmH2O/L/seg para 9 ± 2 cmH2O/L/seg; p < 0,01) e 120 min após (de 10,4 ± 3 cmH2O/L/seg para 9 ± 2 cmH2O/L/seg; p < 0,03) a aplicação do protocolo de fisioterapia respiratória. Quando comparado com o protocolo de aspiração traqueal isolada foi significativamente menor nos momentos 30 (9 ± 2 cmH2O/L/seg versus 10,2 ± 2 cmH2O/L/seg; p < 0,04) e 120 minutos (9 ± 2 cmH2O/L/segundo versus 10,4 ± 3 cmH2O/L/seg; p < 0,04). CONCLUSÕES: O protocolo de fisioterapia respiratória foi eficaz na diminuição da Rsr quando comparado com o protocolo de aspiração. Essa diminuição manteve-se...


BACKGROUND AND OBJECTIVES: The chest physiotherapy (CP) in patients submitted to invasive support ventilation acts directly in the breathing system, and it could alter the lung mechanics through the dynamic lung compliance (DynC) and resistance of the breathing system (Rbs). However the alterations after the accomplishment of CP are still controversy. The objective of this study was to evaluate the alterations of the lung mechanics in patients in invasive mechanical ventilation (IMV). METHODS: It was a prospective, randomized, and controlled and crossover study, with patient with more than 48 hours in IMV. The protocol of chest physiotherapy and isolated tracheal aspiration they were randomized for the application order with a window of 24 hours among them. Data of lung mechanics and its varied cardiorespiratory were collected moments before the protocol, immediately after the application of the protocol, 30 minutes and 120 minutes after the application of the protocols. RESULTS: Twelve patients completed the study. Pneumonia was the mean cause respiratory failure (RF). There was not statistical difference among the groups in relation to Cdyn, volume tidal (Vt) and volume minute (Ve). Rbs decreased in a significant way immediately after (of 10.4 ± 3 cmH2O/L/seg for 8.9 ± 2 cmH2O/L/seg; p < 0.02), 30 minutes after (of 10.4 ± 3 cmH2O/L/seg for 9 ± 2 cmH2O/L/seg; p < 0.01) and 120 minutes after (of 10.4 ± 3 cmH2O/L/seg for 9 ± 2 cmH2O/L/seg; p < 0.03) application the protocol of chest physiotherapy. When compared with the protocol of isolated tracheal aspiration it was significantly smaller in the 30 (9 ± 2 cmH2O/L/seg versus10.2 ± 2 cmH2O/L/seg; p < 0.04) and 120 minutes (9 ± 2 cmH2O/L/seg versus 10.4 ± 3 cmH2O/L/seg; p < 0.04). CONCLUSIONS: The protocol of chest physiotherapy was effective in the decrease of Rsr when compared with the aspiration protocol. That decrease was maintained for two hours after its application, what did not happen...


Subject(s)
Humans , Male , Female , Breathing Exercises , Respiration, Artificial , Suction
SELECTION OF CITATIONS
SEARCH DETAIL
...