Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 90
Filter
1.
Ren Fail ; 46(2): 2369695, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38938162

ABSTRACT

BACKGROUND: This study aims to establish a simplified and effective animal model of catheter malfunction caused by omental wrapped using negative pressure suction. METHOD: The peritoneal dialysis catheter outlet was linked to a negative-pressure (0-75mmHg) suction pump to intensify the negative pressure. Different negative pressures were tested for model construction in vitro. In vivo, a model of peritoneal catheter malfunction caused by omental wrapped was constructed in five beagles after catheter placement. Catheter drainage conditions and related complications were monitored before and after the model establishment. RESULTS: In the vitro experiment, the overall success rate of constructed models was 90% (36/40). The total malfunction rate was higher in 62.5 mmHg (10/10) and 75 mmHg (10/10) than in 12.5 mmHg (8/10) and 37.5 mmHg (8/10). The outflow velocity of dialysate at 62.5 mmHg was significantly lower than that at 12.5 mmHg and 37.5 mmHg, without a statistically significant difference compared to 75 mmHg. In the in vivo experiment, catheter outflow velocity increased, and residual fluid volume decreased after omental wrapped (99.6 ± 6.7 ml/min vs. 32.6 ± 4.6 ml/min at initial five minutes, p < 0.0001; 69.2 ± 16.3 ml vs. 581.0 ± 109.4 ml, p < 0.001). And the outflow velocity was finally below 2 ml/min. No severe related complications (such as infection, organ damage, or bleeding) were observed through laparoscopic examination and dialysate tests seven days post-operation. CONCLUSION: Utilizing negative pressure suction to increase negative pressure around catheter tip is a simple, safe, and effective method for establishing an animal model of omental wrapped leading to catheter malfunction.


Subject(s)
Equipment Failure , Omentum , Peritoneal Dialysis , Animals , Dogs , Suction/instrumentation , Peritoneal Dialysis/instrumentation , Peritoneal Dialysis/adverse effects , Catheters, Indwelling/adverse effects , Disease Models, Animal , Male , Models, Animal
2.
Spine J ; 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38843961

ABSTRACT

BACKGROUND CONTEXT: Although the relationships between paraspinal muscles and lumbar degenerative disorders have been acknowledged, paraspinal muscle evaluation has not been incorporated into clinical therapies. PURPOSE: We aimed to establish a novel paraspinal muscle endurance and morphology (PMEM) score to better predict mechanical complications after lumbar fusion. STUDY DESIGN: Prospective cohort study. PATIENT SAMPLE: A total of 212 patients undergoing posterior lumbar interbody fusion with at least 1 year of follow-up were finally included. OUTCOME MEASURES: Mechanical complications including screw loosening, pseudarthrosis and other complications like cage subsidence, and patient-reported outcomes were evaluated at last follow-up. METHODS: The PMEM score comprised 1 functional muscular parameter (the performance time of the endurance test) and 2 imaging muscular parameters (relative functional cross-sectional area [rFCSA] of paraspinal extensor muscles [PEM] and psoas major [PS] on magnetic resonance imaging). The score was established based on a weighted scoring system created by rounding ß regression coefficients to the nearest integer in univariate logistic regression. The diagnostic performance of the PMEM score was determined by binary logistic regression model and receiver operating characteristic (ROC) curve with the area under the curve (AUC). Additionally, pairwise comparisons of ROC curves were conducted to compare the diagnostic performance of the PMEM score with conventional methods based on a single muscular parameter. Moreover, differences of mechanical complications and patient-reported outcomes among the PMEM categories were analyzed using Chi-square test with Bonferroni correction. RESULTS: The PMEM score, calculated by adding the scores for each parameter, ranges from 0 to 5 points. Patients with higher PMEM scores exhibited higher rates of mechanical complications (p<.001). Binary logistic regression revealed that the PMEM score was an independent factor of mechanical complications (p<.001, OR=2.002). Moreover, the AUC of the PMEM score (AUC=0.756) was significantly greater than those of the conventional methods including the endurance test (AUC=0.691, Z=2.036, p<.05), PEM rFCSA (AUC=.690, Z=2.016, p<.05) and PS rFCSA (AUC=0.640, Z=2.771, p<.01). In terms of the PMEM categories, a score of 0-1 was categorized as low-risk muscular state of mechanical complications; 2-3, as moderate; and 4-5, as high-risk state. Moving from the low-risk state to the high-risk state, there was a progressive increase in the rates of mechanical complications (13.8% vs. 32.1% vs. 72.7%; p<.001), and a decrease in the rates of clinically significant improvement of patient-reported outcomes (all p<.05). CONCLUSIONS: The PMEM score might comprehensively evaluate paraspinal muscle degeneration and exhibit greater ability in predicting mechanical complications than the conventional evaluations after lumbar fusion. Surgeons might develop individualized treatment strategy tailored to different muscle degeneration statuses reflected by the PMEM score for decreasing the risk of mechanical complications.

3.
J Am Coll Cardiol ; 83(18): 1799-1817, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38692830

ABSTRACT

Severe acute mitral regurgitation after myocardial infarction includes partial and complete papillary muscle rupture or functional mitral regurgitation. Although its incidence is <1%, mitral regurgitation after acute myocardial infarction frequently causes hemodynamic instability, pulmonary edema, and cardiogenic shock. Medical management has the worst prognosis, and mortality has not changed in decades. Surgery represents the gold standard, but it is associated with high rates of morbidity and mortality. Recently, transcatheter interventions have opened a new door for management that may improve survival. Mechanical circulatory support restores vital organ perfusion and offers the opportunity for a steadier surgical repair. This review focuses on the diagnosis and the interventional management, both surgical and transcatheter, with a glance on future perspectives to enhance patient management and eventually decrease mortality.


Subject(s)
Mitral Valve Insufficiency , Myocardial Infarction , Humans , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/therapy , Myocardial Infarction/complications , Myocardial Infarction/therapy , Severity of Illness Index , Cardiac Catheterization/methods , Disease Management
4.
Intern Med ; 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38599873

ABSTRACT

The prognosis of myocardial infarction with non-obstructive coronary arteries (MINOCA) is reported to be as worse as myocardial infarction with obstructive coronary arteries. However, its mechanical complications are still poorly understood. A 71-year-old woman developed MINOCA after ascending aortic replacement surgery. During treatment, the patient experienced cardiogenic shock due to a ventricular septal rupture (VSR). The introduction of Impella devices reduced the left-to-right shunt and improved the patient's hemodynamics. Finally, a scheduled surgical repair was performed under stable conditions. In this report, we focused on the pathophysiology of MINOCA-related VSR and discussed the effectiveness of Impella devices as a bridge to surgical repair and circulatory backup during the perioperative period.

5.
Dent Res J (Isfahan) ; 21: 5, 2024.
Article in English | MEDLINE | ID: mdl-38425320

ABSTRACT

Implant-supported prostheses could serve as a reliable restorative option for partial edentulism. Various restorative materials have been utilized in fabricating these prostheses, impacting both esthetics and peri-implant health. The present systematic review aimed to assess the survival rate and mechanical complications of zirconia ceramic compared to metal-ceramic implant-supported multiunit fixed dental prostheses (FDPs). We conducted searches in online databases such as MEDLINE (PubMed), Scopus, and Cochrane up until December 2022. A risk-of-bias assessment was done for all the included studies. Data extraction was performed based on the following parameters: author, year, study design, number of implants, abutment material, age range, observation period, incidence of mechanical complications, and survival rate. This systematic review included six studies (four randomized controlled trials and two retrospective studies). The meta-analysis significantly favored metal-ceramic restorations regarding mechanical complications with a risk ratio (RR) value of 1.64 and P = 0.001. Meta-analysis showed no difference in metal-ceramic FDPs in prostheses survival rate (P = 0.63; RR: 1.27, 95% confidence interval: 0.52-3.37; heterogeneity: P = 0.65; I2: 0%). While metal-ceramic multiunit implant-supported prostheses exhibited fewer mechanical complications compared to zirconia-ceramic prostheses, there was no significant difference in terms of prosthesis survival rate between the two. Hence, both treatments appear to be viable options for long-term implant-supported prostheses.

6.
Eur Spine J ; 33(4): 1311-1319, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38367025

ABSTRACT

PURPOSE: The prevention of mechanical complications (MC) is a major concern in adult spinal deformity (ASD) correction surgery; thus, the global alignment and proportion (GAP) score was developed to assess MC risk. Numerous studies have clarified the validity of the GAP score, but their contradictory results have prevented researchers from reaching compelling conclusions. This study aimed to analyze the predictive power of the GAP score on MC via a meta-analysis. METHODS: A total of 1,617 patients were included in the meta-analysis. Studies relevant to the GAP score and MC were identified in PubMed, EMBASE, and Cochrane CENTRAL and screened according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The GAP score categories of the patients and their MC/revision surgery status were collected. The data collected for the meta-analysis of odds ratios (OR) included the number of patients in the GAP score subgroups and their MC/revision surgery status. To calculate the OR, three GAP score subgroups were combined into two groups; hence, the analysis was conducted twice (gap proportioned [GAP-P] and higher groups, and gap severely disproportioned [GAP-SD] and lower groups). RESULTS: Eleven studies were collected; of them, revision surgery data were available for seven. The proportion of MC in the studies was 27.7-60.6%, while that of revision surgery was 11.7-34.9%. In the meta-analysis of the GAP-P and higher score groups, the difference in MC ratio was significant (OR = 2.83; 95% confidence interval [CI] = 1.20-6.67; P = 0.02), whereas that for revision surgery was not. For the GAP-SD and lower score groups, the GAP-SD group had significantly higher proportions of both MC (OR = 2.65; 95% CI = 1.57-4.45; P < 0.001) and revision surgery (OR = 2.27; 95% CI = 1.33-3.88; P = 0.003). Publication bias was significant only in the latter MC analysis. CONCLUSION: The GAP score offers predictive value for the risk of mechanical complications.


Subject(s)
Postoperative Complications , Adult , Humans , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Retrospective Studies
7.
BMC Anesthesiol ; 24(1): 68, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38383304

ABSTRACT

BACKGROUND: A previous study on mechanical complications after central venous catheterisation demonstrated differences in complication rates between male and female operators. The objective of this subgroup analysis was to further investigate these differences. The hypothesis was that differences in distribution of predefined variables between operator genders could be identified. METHODS: This was a subgroup analysis of a prospective, multicentre, observational cohort study conducted between March 2019 and December 2020 including 8 586 patients ≥ 16 years receiving central venous catheters at four emergency care hospitals. The main outcome measure was major mechanical complications defined as major bleeding, severe cardiac arrhythmia, pneumothorax, arterial catheterisation, and persistent nerve injury. Independent t-test and χ2 test were used to investigate differences in distribution of major mechanical complications and predefined variables between male and female operators. Multivariable logistic regression analysis was used to determine association between operator gender and major mechanical complications. RESULTS: Female operators had a lower rate of major mechanical complications than male operators (0.4% vs 0.8%, P = .02), were less experienced (P < .001), had more patients with invasive positive pressure ventilation (P < .001), more often chose the internal jugular vein (P < .001) and more frequently used ultrasound guidance (P < .001). Male operators more often chose the subclavian vein (P < .001) and inserted more catheters with bore size ≥ 9 Fr (P < .001). Multivariable logistic regression analysis showed that male operator gender was associated with major mechanical complication (OR 2.67 [95% CI: 1.26-5.64]) after correction for other relevant independent variables. CONCLUSIONS: The hypothesis was confirmed as differences in distribution of predefined variables between operator genders were found. Despite being less experienced, female operators had a lower rate of major mechanical complications. Furthermore, male operator gender was independently associated with a higher risk of major mechanical complications. Future studies are needed to further investigate differences in risk behaviour between male and female operators. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03782324. Date of registration: 20/12/2018.


Subject(s)
Catheterization, Central Venous , Central Venous Catheters , Female , Humans , Male , Catheterization, Central Venous/adverse effects , Central Venous Catheters/adverse effects , Jugular Veins , Prospective Studies , Sex Factors , Ultrasonography , Adolescent , Multicenter Studies as Topic , Observational Studies as Topic , Adult
8.
J Orthop Sci ; 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38331601

ABSTRACT

BACKGROUND: This study aimed to determine the impact of the multi-rod construct on rod fractures over a minimum follow-up period of five years in comparison to that with the conventional two-rod construct using the same technique, rod composition, and rod reinforcement method. METHODS: Data were retrospectively retrieved from a prospectively collected, single-center database. Consecutive patients >50 years of age who underwent thoracopelvic corrective fusion with planned two-stage anterior-posterior surgery and were followed up for at least five years were included in this study. The incidence of rod fracture in the conventional two-rod and multi-rod groups was investigated. RESULTS: A total of 58 patients (mean age, 68.9 years) were included in this study (follow-up rate, 73.4 %). Rod fracture was identified in 25 patients (43.1 %), within an average period of 25.1 months. The incidence of rod fracture in the multi-rod group was significantly lower than that in the two-rod group. However, there was no significant difference in the time to rod fracture between the two groups. Reinforcement of the multi-rod to the distal portion of the connector of the iliac screw had the lowest fracture rate and no cases of reoperation. CONCLUSIONS: The incidence of rod fracture was significantly lower using multi-rod reinforcement, but the timing of rod fracture did not differ, compared to that with the two-rod construct using the same surgical technique and rod material. Multi-rod reinforcement covering the distal portion of the iliac screw is recommended to reduce the risk of fracture and reoperation.

10.
Heart Vessels ; 39(4): 288-298, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38008806

ABSTRACT

Mechanical complication (MC) is a rare but serious complication in patients with ST-segment elevation myocardial infarction (STEMI). Although several risk factors for MC have been reported, a prediction model for MC has not been established. This study aimed to develop a simple prediction model for MC after STEMI. We included 1717 patients with STEMI who underwent primary percutaneous coronary intervention (PCI). Of 1717 patients, 45 MCs occurred after primary PCI. Prespecified predictors were determined to develop a tentative prediction model for MC using multivariable regression analysis. Then, a simple prediction model for MC was generated. Age ≥ 70, Killip class ≥ 2, white blood cell ≥ 10,000/µl, and onset-to-visit time ≥ 8 h were included in a simple prediction model as "point 1" risk score, whereas initial thrombolysis in myocardial infarction (TIMI) flow grade ≤ 1 and final TIMI flow grade ≤ 2 were included as "point 2" risk score. The simple prediction model for MC showed good discrimination with the optimism-corrected area under the receiver-operating characteristic curve of 0.850 (95% CI: 0.798-0.902). The predicted probability for MC was 0-2% in patients with 0-4 points of risk score, whereas that was 6-50% in patients with 5-8 points. In conclusion, we developed a simple prediction model for MC. We may be able to predict the probability for MC by this simple prediction model.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/surgery , Percutaneous Coronary Intervention/adverse effects , Time Factors , Treatment Outcome , Risk Factors
11.
Eur Heart J Open ; 3(5): oead091, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37840585

ABSTRACT

Aims: Many historical and recent reports showed that post-infarction ventricular septal rupture (VSR) represents a life-threatening condition and the strategy to optimally manage it remains undefined. Therefore, disparate treatment policies among different centres with variable results are often described. We analysed data from European centres to capture the current clinical practice in VSR management. Methods and results: Thirty-nine centres belonging to eight European countries participated in a survey, filling a digital form of 38 questions from April to October 2022, to collect information about all the aspects of VSR treatment. Most centres encounter 1-5 VSR cases/year. Surgery remains the treatment of choice over percutaneous closure (71.8% vs. 28.2%). A delayed repair represents the preferred approach (87.2%). Haemodynamic conditions influence the management in almost all centres, although some try to achieve patients stabilization and delayed surgery even in cardiogenic shock. Although 33.3% of centres do not perform coronarography in unstable patients, revascularization approaches are widely variable. Most centres adopt mechanical circulatory support (MCS), mostly extracorporeal membrane oxygenation, especially pre-operatively to stabilize patients and achieve delayed repair. Post-operatively, such MCS are more often adopted in patients with ventricular dysfunction. Conclusion: In real-life, delayed surgery, regardless of the haemodynamic conditions, is the preferred strategy for VSR management in Europe. Extracorporeal membrane oxygenation is becoming the most frequently adopted MCS as bridge-to-operation. This survey provides a useful background to develop dedicated, prospective studies to strengthen the current evidence on VSR treatment and to help improving its currently unsatisfactory outcomes.

12.
JA Clin Rep ; 9(1): 58, 2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37672125

ABSTRACT

BACKGROUND: Ultrasound-guided central venous catheterization has become a standard procedure. However, mechanical complications are still reported. CASE PRESENTATION: An 85-year-old woman presented with coagulopathic bladder tamponade. Ultrasound-guided right internal jugular venous catheterization was planned because of difficult peripheral venous access. A guidewire was advanced through a needle inserted at the midpoint of the right carotid triangle. The guidewire was identified in the short axis, but not in the long-axis ultrasound view, leading to inadvertent insertion of the catheter into the right subclavian artery through the internal jugular vein. Stent graft insertion was performed for perforation closure. The patient exhibited no symptoms of cerebral ischemia following stent graft insertion. DISCUSSION: This case demonstrated that the needle-sticking site should not be placed close to the clavicle for ultrasound-guided internal jugular venous catheterization, as it may not confirm the position of guidewire in the long-axis ultrasound view.

13.
Eur Heart J Case Rep ; 7(8): ytad393, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37637096

ABSTRACT

Background: Ventricular septal defect (VSD) complicating acute myocardial infarction (MI) represents a life-threatening condition and has a mortality of >90% if left untreated. Case summary: A 53-year-old man with a prior medical history of diabetes and hypertension presented with cardiogenic shock secondary to VSD as a mechanical complication of non-reperfused inferior MI. Discussion: The choice of mechanical support can be difficult in this type of patient. Given the risk of an increased shunt because of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) and the increase in left ventricle (LV) afterload, several measures were taken to plan the best ECMO configuration. Given the absence of any real improvement in the LV and an elevated residual ratio between pulmonary and systemic flow (Qp/Qs), the final decision was to switch to left atrial VA-ECMO (LAVA-ECMO). The use of LAVA-ECMO improved the patient's haemodynamics and allowed his condition to stabilize; LAVA-ECMO is feasible and may be effective as a mechanical circulatory support (MCS) strategy for patients in cardiogenic shock due to VSD as a mechanical complication of acute MI.

14.
Global Spine J ; : 21925682231196449, 2023 Aug 18.
Article in English | MEDLINE | ID: mdl-37596769

ABSTRACT

STUDY DESIGN: A multi-institutional retrospective study. OBJECTIVES: To investigate risk factors of mechanical failure in three-column osteotomy (3COs) in patients with adult spinal deformity (ASD), focusing on the osteotomy level. METHODS: We retrospectively reviewed 111 patients with ASD who underwent 3COs with at least 2 years of follow-up. Radiographic parameters, clinical data on early and late postoperative complications were collected. Surgical outcomes were compared between the low-level osteotomy group and the high-level osteotomy group: osteotomy level of L3 or lower group (LO group, n = 60) and osteotomy of L2 or higher group (HO group, n = 51). RESULTS: Of the 111 patients, 25 needed revision surgery for mechanical complication (mechanical failure). A lower t-score (odds ratio [OR] .39 P = .002) and being in the HO group (OR 4.54, P = .03) were independently associated with mechanical failure. In the analysis divided by the osteotomy level (LO and HO), no difference in early complications or neurological complications was found between the two groups. The rates of overall mechanical complications, rod failure, and mechanical failure were significantly higher in the HO group than in the LO group. After propensity score matching, mechanical complications and failures were still significantly more observed in the HO group than in the LO group (P = .01 and .029, respectively). CONCLUSIONS: A lower t-score and osteotomy of L2 or higher were associated with increased risks of mechanical failure. Lower osteotomy was associated with better correction of sagittal balance and a lower rate of mechanical complications.

16.
Clin Oral Implants Res ; 34(10): 1038-1046, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37464268

ABSTRACT

OBJECTIVES: To assess the impact of implantoplasty (IP) on maximum implant failure strength of narrow diameter implants of different type/design and material, with simulated advanced bone loss. MATERIALS AND METHODS: Narrow, parallel-walled implants (3.3 mm in diameter × 10 mm long) with an internal connection of different type/design [bone level (BL), tissue level (TL)] and material [Titanium grade IV (Ti), Titanium-Zirconium alloy (TiZr)] from one specific manufacturer were used. Half of the implants were subjected to IP in their coronal 5 mm; the remaining were used as controls (seven implants per group). Dynamic loading prior to maximum load strength testing was included. RESULTS: During dynamic loading, the fracture rate of BL implants was low and independent of IP, while that of TL implants increased significantly with IP compared with controls (p = .001). Maximum implant failure strength reduction (in %) due to IP, was 1.3%-25.4%; TiZr BL implants were least affected. Implants subjected to IP compared to those without IP as well as TL implants compared to BL implants showed a significantly lower maximum implant failure strength (p < .002); implant material was not significant (p = .845). CONCLUSIONS: Based on data from implants of one specific manufacturer, IP has a significant negative impact on the fracture strength of narrow implants suffering from advanced peri-implantitis. TL implants have been more severely affected compared to BL implants and presented an increased risk for failure during normal chewing forces. In addition, this negative impact of IP on TL implants was independent of the implant material (i.e., Ti or TiZr). CLINICAL RELEVANCE: Narrow single TL implants with advanced horizontal bone loss (e.g., 5 mm), when subjected to IP, appear to have an increased fracture risk during normal function.


Subject(s)
Dental Implants , Titanium , Dental Materials , Alloys , Zirconium
17.
Spine Surg Relat Res ; 7(3): 276-283, 2023 May 27.
Article in English | MEDLINE | ID: mdl-37309490

ABSTRACT

Introduction: Mechanical complications, such as rod fracture (RF) and proximal junctional kyphosis (PJK), commonly occur after adult spinal deformity (ASD) surgery. A rigid construct is preferred to prevent RF, whereas it is a risk factor for PJK. This controversial issue urged us to conduct a biomechanical study for seeking the optimal construct to prevent mechanical complications. Methods: A three-dimensional nonlinear finite element model, which consisted of the lower thoracic and lumbar spine, pelvis, and femur, was created. The model was instrumented with pedicle screws (PSs), S2-alar-iliac screws, lumbar interbody fusion cages, and rods. Rod stress was measured when a forward-bending load was applied at the top of the construct to evaluate the risk of RF in constructs with or without accessory rods (ARs). In addition, fracture analysis around the uppermost instrumented vertebra (UIV) was performed to assess the risk of PJK. Results: Changing the rod material from titanium alloy (Ti) to cobalt chrome (CoCr) decreased shearing stress at L5-S1 by 11.5%, and adding ARs decreased it by up to 34.3% (for the shortest ARs). Although the trajectory (straightforward vs. anatomical) of PSs did not affect the fracture load for UIV+1, changing the anchor from PSs to hooks at the UIV reduced it by 14.8%. Changing the rod material from Ti to CoCr did not alter the load, whereas the load decreased by up to 25.1% as the AR became longer. Conclusions: The PSs at the UIV in the lower thoracic spine, CoCr rods as primary rods, and shorter ARs should be used in long fusion for ASD to prevent mechanical complications.

18.
Neurospine ; 20(1): 265-274, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37016873

ABSTRACT

OBJECTIVE: This study aimed to create an ideal machine learning model to predict mechanical complications in adult spinal deformity (ASD) surgery based on GAPB (modified global alignment and proportion scoring with body mass index and bone mineral density) factors. METHODS: Between January 2009 and December 2018, 238 consecutive patients with ASD, who received at least 4-level fusions and were followed-up for ≥ 2 years, were included in the study. The data were stratified into training (n = 167, 70%) and test (n = 71, 30%) sets and input to machine learning algorithms, including logistic regression, random forest gradient boosting system, and deep neural network. RESULTS: Body mass index, bone mineral density, the relative pelvic version score, the relative lumbar lordosis score, and the relative sagittal alignment score of the global alignment and proportion score were significantly different in the training and test sets (p < 0.05) between the complication and no complication groups. In the training set, the area under receiver operating characteristics (AUROCs) for logistic regression, gradient boosting, random forest, and deep neural network were 0.871 (0.817-0.925), 0.942 (0.911-0.974), 1.000 (1.000-1.000), and 0.947 (0.915-0.980), respectively, and the accuracies were 0.784 (0.722-0.847), 0.868 (0.817-0.920), 1.000 (1.000-1.000), and 0.856 (0.803-0.909), respectively. In the test set, the AUROCs were 0.785 (0.678-0.893), 0.808 (0.702-0.914), 0.810 (0.710-0.910), and 0.730 (0.610-0.850), respectively, and the accuracies were 0.732 (0.629-0.835), 0.718 (0.614-0.823), 0.732 (0.629-0.835), and 0.620 (0.507-0.733), respectively. The random forest achieved the best predictive performance on the training and test dataset. CONCLUSION: This study created a comprehensive model to predict mechanical complications after ASD surgery. The best prediction accuracy was 73.2% for predicting mechanical complications after ASD surgery.

19.
Rev Port Cardiol ; 42(9): 775-783, 2023 09.
Article in English, Portuguese | MEDLINE | ID: mdl-36948458

ABSTRACT

INTRODUCTION AND OBJECTIVE: We performed a collective analysis of a dedicated national post-myocardial infarction ventricular septal defect (VSD) registry to further elucidate controversial areas of this clinical entity's surgical treatment. METHODS: A descriptive statistical analysis was carried out and cumulative survival using the Kaplan-Meier method and multivariate logistic regression of risk factors for 30-day mortality are presented. RESULTS: Median survival of the cohort (n=76) was 72 months (95% CI 4-144 months). Better cumulative survival was observed in patients who underwent VSD closure more than 10 days after myocardial infarction (log-rank p=0.036). Concomitant coronary artery bypass grafting (CABG), different closure techniques, location of the VSD, extracorporeal membrane oxygenation as bridge to closure, or intra-aortic balloon pump as bridge to closure showed no statistically significant differences at Kaplan-Meier analysis. Multivariate binary logistic regression for independent factors affecting status at 30 days showed a statistically significant effect of age (OR 1.08; 95% CI 1.01-1.15) and concomitant CABG (OR 0.23; 95% CI 0.06-0.90). CONCLUSIONS: Our results are comparable with previous reports regarding mortality, risk factors and concomitant procedures. Timing of surgery remains a controversial issue. Later closure seems to be advantageous, however, there is significant observational bias.


Subject(s)
Heart Septal Defects, Ventricular , Myocardial Infarction , Ventricular Septal Rupture , Humans , Ventricular Septal Rupture/etiology , Ventricular Septal Rupture/surgery , Treatment Outcome , Portugal , Heart Septal Defects, Ventricular/surgery , Heart Septal Defects, Ventricular/etiology , Myocardial Infarction/surgery , Myocardial Infarction/complications
20.
J Arthroplasty ; 38(6): 1104-1109, 2023 06.
Article in English | MEDLINE | ID: mdl-36535449

ABSTRACT

BACKGROUND: The impact of implanting cementless femoral stems in varus alignment on long-term mechanical complications remains poorly defined in the literature. The aim of our study was to compare survivorship and functional and radiographic outcomes of stems in varus alignment to those in neutral alignment with and average follow-up of 10 years. METHODS: This single-center, multisurgeon, retrospective case-control study compared a group of 105 total hip arthroplasty (THA) patients who had varus stem alignment (Varus Stem) to a matching group of 105 THA patients who had neutral stem alignment, operated on between January 2007 and December 2012. The primary outcome measure was implant survival. Secondary outcomes included functional (Harris Hip Score, Postel Merle d'Aubigné Score, thigh pain, dislocation and hip range of motion) and radiographic outcomes (radiolucency, osseointegration, heterotopic ossification, subsidence, and stress shielding). RESULTS: There was no significant difference in implant survival between the 2 groups with 95.7% (±2.46) in the Varus Stem group versus 97.7% (±1.64) in the Neutral Stem group (P = .41) after an average follow-up of 10 years. There was no significant difference in clinical and radiographic outcomes between groups. CONCLUSION: Cementless femoral stems in varus alignment were not the cause of mechanical complications with an average follow-up of 10 years. The comparison between groups in terms of implant survival, functional, and radiographic outcomes does not show any significant differences. Positioning a femoral stem in varus alignment may be an alternative for surgeons wishing to restore preoperative offset and to ensure satisfactory hip stability.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/adverse effects , Hip Joint/diagnostic imaging , Hip Joint/surgery , Hip Prosthesis/adverse effects , Retrospective Studies , Case-Control Studies , Prosthesis Design , Risk Factors , Follow-Up Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...