AJR Am J Roentgenol ; 215(2): 374-381, 2020 08.
Article in English | MEDLINE | ID: mdl-32374663

ABSTRACT

OBJECTIVE. Patients with cardiac implantable electronic devices (CIEDs) require cardiac MRI (CMRI) for a variety of reasons. The purpose of this study is to review and evaluate the value and safety of CMRI for patients with in situ CIEDs. CONCLUSION. Late gadolinium enhancement CMRI is the reference standard for assessing myocardial viability in patients with ventricular tachycardia before ablation of arrhythmogenic substrates. The use of late gadolinium enhancement CMRI for patients with CIEDs is safe as long as an imaging protocol is in place and precaution measures are taken.


Subject(s)
Cardiac Imaging Techniques , Contrast Media , Defibrillators, Implantable , Gadolinium , Heart/diagnostic imaging , Magnetic Resonance Imaging/adverse effects , Pacemaker, Artificial , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Aged , Cardiac Imaging Techniques/methods , Female , Humans
2.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-186067

ABSTRACT

PURPOSE: The purpose of this study is to report the results of culture test at the time of removal of metal devices used for management of ankle fractures and for analysis of contributing factors. MATERIALS AND METHODS: We reviewed medical records of 132 patients with lower tibia and ankle fracture who had their metal devices removed during the period from January 2010 to February 2014. Patients with clinical signs of infection were excluded. Culture test was performed by taking the granulation tissue around the metal device at the time of removal. We divided the subjects into two groups, culture positive and negative. We then performed a retrospective review of each medical record of multiple factors that might contribute to the culture results, including laboratory results, medical history, material and size of metal device, indwelling period, and whether or not it was open injury. RESULTS: Among 132 cases, six were culture positive. Enterococcus was detected in two cases and the others were Staphylococcus. No significant difference in medical history of patients and laboratory results, including C-reactive protein level, was observed between the culture positive and negative group. Culture positive rate was 5.4% in titanium and 3.9% in stainless steel. In terms of metal size, culture positive rate was 5.1% in small plates, 6.7% in large plates, and culture negative in intramedullary nails. The average indwelling period of metal device was 61.5 weeks in the culture positive group, and 68.6 weeks in the negative group. Nine cases were open fractures and all were in the culture negative group. CONCLUSION: Whether or not the culture result was positive, there were no meaningful contributing factors. Presence of bacterium on the metal device could not be screened by any laboratory results or other factors.


Subject(s)
Humans , Ankle , Ankle Fractures , C-Reactive Protein , Enterococcus , Fractures, Open , Granulation Tissue , Medical Records , Retrospective Studies , Stainless Steel , Staphylococcus , Tibia , Titanium
3.
Open Orthop J ; 6: 488-94, 2012.
Article in English | MEDLINE | ID: mdl-23193432

ABSTRACT

A consecutive series of 52 acetabular revisions was evaluated retrospectively. Inclusion criteria for all patients were at least one former exchange of the acetabular component. Reconstruction was performed with reliable techniques and implants other than extensively porous coated device (e.g. tantalum). The mean follow up was 5.63 (0.01-14.05) years. Cumulative survival at 14.05 years with removal of the acetabular component due to aseptic loosening or the worst case criterion (removal of the acetabular component for any cause and/or lost to follow-up) as the end point was 66.38 (95 % C.-I.: 47.80-84.96) % and 58.42 (95 % C.-I.: 41.01-75.83) %, respectively. The cumulative survival rate with mechanical failure of the acetabular reconstruction as the endpoint was significantly lower in patients with two or more previous revisions in comparison to those with only one former procedure (log rank test: p=0,0112 respectively). The mean Merle d'Aubignée-score improved from 7.3 (0-14) preoperatively to 10.6 (0-17) points at latest follow up examination.Survival of acetabular reconstructions with common techniques and implants is decreasing with the number of previous revisions. This may cause major concerns with regard to the rising number of patients needing repeated revisions. Maximizing durability of primary THA, precise preoperative planning as well as improved techniques and implants for revision may decrease this problem in the long term.