Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 138
Filter
1.
Neuromodulation ; 2024 Jun 09.
Article in English | MEDLINE | ID: mdl-38852085

ABSTRACT

OBJECTIVES: Anesthetic agents used during deep brain stimulation (DBS) surgery might interfere with microelectrode recording (MER) and local field potential (LFP) and thus affect the accuracy of surgical target localization. This review aimed to identify the effects of different anesthetic agents on neuronal activity of the subthalamic nucleus (STN) during the MER procedure. MATERIALS AND METHODS: We used Medical Subject Heading terms to search the PubMed, EMBASE, EBSCO, and ScienceDirect data bases. MER characteristics were sorted into quantitative and qualitative data types. Quantitative data included the burst index, pause index, firing rate (FR), and interspike interval. Qualitative data included background activity, burst discharge (BD), and anesthetic agent effect. We also categorized the reviewed manuscripts into those describing local anesthesia with sedation (LAWS) and those describing general anesthesia (GA) and compiled the effects of anesthetic agents on MER and LFP characteristics. RESULTS: In total, 26 studies on MER were identified, of which 12 used LAWS and 14 used GA. Three studies on LFP also were identified. We found that the FR was preserved under LAWS but tended to be lower under GA, and BD was reduced in both groups. Individually, propofol enhanced BD but was better used for sedation, or the dosage should be minimized in GA. Similarly, low-dose dexmedetomidine sedation did not disturb MER. Opioids could be used as adjunctive anesthetic agents. Volatile anesthesia had the least adverse effect on MER under GA, with minimal alveolar concentration at 0.5. Dexmedetomidine anesthesia did not affect LFP, whereas propofol interfered with the power of LFP. CONCLUSIONS: The effects of the tested anesthetics on the STN in MER and LFP of Parkinson's disease varied; however, identifying the STN and achieving a good clinical outcome are possible under controlled anesthetic conditions. For patient comfort, anesthesia should be considered in STN-DBS.

2.
Front Neurosci ; 18: 1389556, 2024.
Article in English | MEDLINE | ID: mdl-38817909

ABSTRACT

Introduction: Available evidence suggests that as we age, our brain and immune system undergo changes that increase our susceptibility to injury, inflammation, and neurodegeneration. Since a significant portion of the potential patients treated with a microelectrode-based implant may be older, it is important to understand the recording performance of such devices in an aged population. Methods: We studied the chronic recording performance and the foreign body response (FBR) to a clinically used microelectrode array implanted in the cortex of 18-month-old Sprague Dawley rats. Results and discussion: To the best of our knowledge, this is the first preclinical study of its type in the older mammalian brain. Here, we show that single-unit recording performance was initially robust then gradually declined over a 12-week period, similar to what has been previously reported using younger adult rats and in clinical trials. In addition, we show that FBR biomarker distribution was similar to what has been previously described for younger adult rats implanted with multi-shank recording arrays in the motor cortex. Using a quantitative immunohistochemcal approach, we observed that the extent of astrogliosis and tissue loss near the recording zone was inversely related to recording performance. A comparison of recording performance with a younger cohort supports the notion that aging, in and of itself, is not a limiting factor for the clinical use of penetrating microelectrode recording arrays for the treatment of certain CNS disorders.

3.
Neurocirugía (Soc. Luso-Esp. Neurocir.) ; 35(2): 79-86, Mar-Abr. 2024. tab
Article in English | IBECS | ID: ibc-231278

ABSTRACT

Objectives: Report the incidence of symptomatic and asymptomatic intracerebral hemorrhage (ICH) in patients submitted to deep brain stimulation (DBS) guided with microelectrode recording (MER) with further analysis of potential risk factors, both inherent to the patient and related to the pathology and surgical technique. Methods: We performed a retrospective observational study. 297 DBS procedures were concluded in 277 patients in a single hospital centre between January 2010 and December 2020. All surgeries were guided with MER. We analysed the incidence of symptomatic and asymptomatic ICH and its correlation to age, sex, diagnosis, hypertension and perioperative hypertension, diabetes, dyslipidaemia, antiplatelet drugs, anatomic target, and number of MER trajectories. Results: There were a total of 585 electrodes implanted in 277 patients. 16 ICH were observed, of which 6 were symptomatic and 10 asymptomatic, none of which incurred in permanent neurological deficit. The location of the hemorrhage varied between cortical and subcortical plans, always in relation with the trajectory or the final position of the electrode. The incidence of symptomatic ICH per lead-implantation was 1%, and the CT-scan demonstrated asymptomatic ICH in 1.7% more patients. Male patients or with hypertension are 2.7 and 2.2 times more likely to develop ICH, respectively. However, none of these characteristics has been shown to have a statistically significant association with the occurrence of ICH, as well as age, diagnosis, diabetes, dyslipidaemia, antiplatelet drugs, anatomic target, number of MER trajectories and perioperative hypertension. Conclusions: MER-guided DBS is a safe technique, with low incidence of ICH and no permanent deficits in our study. Hypertension and male sex seem to be risk factors for the development of ICH in this surgery. Nevertheless, no statistically significant factors were found for the occurrence of this complication.(AU)


Objetivos: Reportar la incidencia de hemorragia intracerebral (HIC) sintomática y asintomática en pacientes sometidos a estimulación cerebral profunda (ECP) guiada por microrregistro (MER), con el consecuente análisis de posibles factores de riesgo, tanto inherentes al paciente como relacionados con la patología y técnica quirúrgica. Métodos: Realizamos un estudio observacional retrospectivo. Se analizaron un total de 297 procedimientos de ECP realizados en 277 pacientes en un centro hospitalario entre enero de 2010 y diciembre de 2020. Todas las cirugías fueron guiadas con MER. Analizamos la incidencia de HIC, tanto sintomática como asintomática, y la correlación con edad, sexo, diagnóstico, hipertensión arterial e intraoperatoria, diabetes, dislipemia, medicación antiplaquetaria previa, diana anatómica y número de vías. Resultados: El número total de electrodos implantados fue de 585 en 277 pacientes. Se observaron 16 HIC, de las cuales 10 fueron asintomáticas y 6 sintomáticas y ninguna incurrió en déficit neurológico permanente. La localización de la hemorragia varió entre planos corticales y subcorticales, siempre en relación con el trayecto o posición final del electrodo. La incidencia de hemorragia sintomática fue de alrededor del 1 %, y la TC posoperatoria demostró hemorragia asintomática en un 1,7 % adicional de los pacientes. Los pacientes varones o los pacientes con hipertensión tienen 2,7 y 2,2 veces más probabilidades de desarrollar sangrado, respectivamente. Sin embargo, ninguna de estas características demostró una asociación estadísticamente significativa con la ocurrencia de hemorragia intracerebral, como la edad, el diagnóstico, la diabetes, la dislipidemia, la ingesta previa de medicamentos antiplaquetarios, el objetivo anatómico, el número de MER y las vías de HTA intraoperatorias. Conclusión: La ECP con MER es una técnica segura, con baja incidencia de HIC y sin déficits permanentes en nuestro estudio...(AU)


Subject(s)
Humans , Male , Female , Cerebral Hemorrhage , Risk Factors , Incidence , Deep Brain Stimulation , Retrospective Studies , Neurosurgery
4.
Article in English | MEDLINE | ID: mdl-38617832

ABSTRACT

Clinical vignette: We present the case of a patient who developed intra-operative pneumocephalus during left globus pallidus internus deep brain stimulation (DBS) placement for Parkinson's disease (PD). Microelectrode recording (MER) revealed that we were anterior and lateral to the intended target. Clinical dilemma: Clinically, we suspected brain shift from pneumocephalus. Removal of the guide-tube for readjustment of the brain target would have resulted in the introduction of movement resulting from brain shift and from displacement from the planned trajectory. Clinical solution: We elected to leave the guide-tube cannula in place and to pass the final DBS lead into a channel that was located posterior-medially from the center microelectrode pass. Gap in knowledge: Surgical techniques which can be employed to minimize brain shift in the operating room setting are critical for reduction in variation of the final DBS lead placement. Pneumocephalus after dural opening is one potential cause of brain shift. The recognition that the removal of a guide-tube cannula could worsen brain shift creates an opportunity for an intraoperative team to maintain the advantage of the 'fork' in the brain provided by the initial procedure's requirement of guide-tube placement.


Subject(s)
Deep Brain Stimulation , Pneumocephalus , Humans , Deep Brain Stimulation/adverse effects , Pneumocephalus/diagnostic imaging , Pneumocephalus/etiology , Pneumocephalus/therapy , Brain/diagnostic imaging , Brain/surgery , Globus Pallidus/diagnostic imaging , Globus Pallidus/surgery , Movement
5.
Neural Netw ; 170: 18-31, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37972454

ABSTRACT

During the Deep Brain Stimulation (DBS) surgery for Parkinson's disease (PD), the main goal is to place the permanent stimulating electrode into an area of the brain that becomes pathologically hyperactive. This area, called Subthalamic Nucleus (STN), is small and located deep within the brain. Therefore, the main challenge is the precise localization of the STN region, considering various measurement errors and artifacts. In this paper, we have designed and developed a computer-aided decision support system for neurosurgical DBS surgery. The implementation of this system provides a novel method for calculating the expected position of the stimulating electrode based on the recordings of the electrical activity of brain tissue. The artificial neural network with attention is used to classify the microelectrode recordings and determine the final position of the stimulating electrode within the STN area. Experiments have verified the utility and efficiency of our system. The tests were carried out on many recordings collected during DBS surgeries, giving encouraging results. The experimental results demonstrate that deep learning methods extended with self-attention blocks compete with the other solutions. They provide significant robustness to recording artifacts and improve the accuracy of the stimulating electrode placement.


Subject(s)
Deep Brain Stimulation , Parkinson Disease , Subthalamic Nucleus , Humans , Deep Brain Stimulation/methods , Microelectrodes , Electrodes, Implanted , Parkinson Disease/diagnosis , Parkinson Disease/surgery , Subthalamic Nucleus/physiology
6.
Neurocirugia (Astur : Engl Ed) ; 35(2): 79-86, 2024.
Article in English | MEDLINE | ID: mdl-37865159

ABSTRACT

OBJECTIVES: Report the incidence of symptomatic and asymptomatic intracerebral hemorrhage (ICH) in patients submitted to deep brain stimulation (DBS) guided with microelectrode recording (MER) with further analysis of potential risk factors, both inherent to the patient and related to the pathology and surgical technique. METHODS: We performed a retrospective observational study. 297 DBS procedures were concluded in 277 patients in a single hospital centre between January 2010 and December 2020. All surgeries were guided with MER. We analysed the incidence of symptomatic and asymptomatic ICH and its correlation to age, sex, diagnosis, hypertension and perioperative hypertension, diabetes, dyslipidaemia, antiplatelet drugs, anatomic target, and number of MER trajectories. RESULTS: There were a total of 585 electrodes implanted in 277 patients. 16 ICH were observed, of which 6 were symptomatic and 10 asymptomatic, none of which incurred in permanent neurological deficit. The location of the hemorrhage varied between cortical and subcortical plans, always in relation with the trajectory or the final position of the electrode. The incidence of symptomatic ICH per lead-implantation was 1%, and the CT-scan demonstrated asymptomatic ICH in 1.7% more patients. Male patients or with hypertension are 2.7 and 2.2 times more likely to develop ICH, respectively. However, none of these characteristics has been shown to have a statistically significant association with the occurrence of ICH, as well as age, diagnosis, diabetes, dyslipidaemia, antiplatelet drugs, anatomic target, number of MER trajectories and perioperative hypertension. CONCLUSIONS: MER-guided DBS is a safe technique, with low incidence of ICH and no permanent deficits in our study. Hypertension and male sex seem to be risk factors for the development of ICH in this surgery. Nevertheless, no statistically significant factors were found for the occurrence of this complication.


Subject(s)
Deep Brain Stimulation , Diabetes Mellitus , Dyslipidemias , Hypertension , Humans , Male , Deep Brain Stimulation/adverse effects , Deep Brain Stimulation/methods , Microelectrodes , Platelet Aggregation Inhibitors , Cerebral Hemorrhage/epidemiology , Cerebral Hemorrhage/etiology , Hypertension/epidemiology , Hypertension/etiology , Diabetes Mellitus/etiology , Dyslipidemias/complications
7.
World Neurosurg ; 181: e346-e355, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37839566

ABSTRACT

BACKGROUND: Deep brain stimulation of the subthalamic nucleus (STN-DBS) for Parkinson's disease can be performed with intraoperative neurophysiological and radiographic guidance. Conventional T2-weighted magnetic resonance imaging sequences, however, often fail to provide definitive borders of the STN. Novel magnetic resonance imaging sequences, such as susceptibility-weighted imaging (SWI), might better localize the STN borders and facilitate radiographic targeting. We compared the radiographic location of the dorsal and ventral borders of the STN using SWI with intraoperative microelectrode recording (MER) during awake STN-DBS for Parkinson's disease. METHODS: Thirteen consecutive patients who underwent placement of 24 STN-DBS leads for Parkinson's disease were analyzed retrospectively. Preoperative targeting was performed with SWI, and MER data were obtained from intraoperative electrophysiology records. The boundaries of the STN on SWI were identified by a blinded investigator. RESULTS: The final electrode position differed significantly from the planned coordinates in depth but not in length or width, indicating that MER guided the final electrode depth. When we compared the boundaries of the STN by MER and SWI, SWI accurately predicted the entry into the STN but underestimated the length and ventral boundary of the STN by 1.2 mm. This extent of error approximates the span of a DBS contact and could affect the placement of directional contacts within the STN. CONCLUSIONS: MER might continue to have a role in STN-DBS. This could potentially be mitigated by further refinement of imaging protocols to better image the ventral boundary of the STN.


Subject(s)
Deep Brain Stimulation , Parkinson Disease , Subthalamic Nucleus , Humans , Subthalamic Nucleus/diagnostic imaging , Subthalamic Nucleus/surgery , Subthalamic Nucleus/physiology , Deep Brain Stimulation/methods , Microelectrodes , Parkinson Disease/diagnostic imaging , Parkinson Disease/surgery , Retrospective Studies , Magnetic Resonance Imaging/methods , Electrodes, Implanted
8.
J Neurosurg ; : 1-9, 2023 Nov 03.
Article in English | MEDLINE | ID: mdl-37922545

ABSTRACT

OBJECTIVE: Functional stereotactic neurosurgery including deep brain stimulation (DBS) and radiofrequency lesioning is well established and widely used for treatment of movement disorders and various other neurological and psychiatric diseases. Although functional stereotactic neurosurgery procedures are considered relatively safe, intracranial hemorrhage resulting in permanent neurological deficits may occur in 1%-3% of patients. Microelectrode recording (MER) has been recognized as a valuable tool for refining the final target in functional stereotactic neurosurgery. Moreover, MER provides insight into the underlying neurophysiological pathomechanisms of movement disorders and other diseases. Nevertheless, there is an ongoing controversy on whether MER increases the risk for hemorrhage. The authors aimed to compare the risk of hemorrhage in functional stereotactic neurosurgical procedures with regard to the use of MER. METHODS: The authors performed a comparative analysis on a consecutive series of 645 functional neurosurgery procedures, including 624 DBS surgeries and 21 radiofrequency lesionings, to evaluate whether the use of MER would increase the risk for hemorrhage. MER was performed in 396 procedures, while no MER was used in 249 cases. The MER technique involved the use of a guiding cannula and a single trajectory when feasible. Postoperative CT scans were obtained within 24 hours after surgery in all patients and screened for the presence of hemorrhage. RESULTS: Twenty-one intracranial hemorrhages were detected on the postoperative CT scans (3.2%). Of the 21 intracranial hemorrhages, 14 were asymptomatic and 7 were symptomatic. Symptoms were transient except in 1 case. There was no statistically significant correlation between hemorrhage and the use of MER at any site (subdural, ventricle, trajectory, target, whether asymptomatic or symptomatic). There were 4 cases of symptomatic hemorrhage in the MER group (1%) and 3 cases in those without MER (1.2%). CONCLUSIONS: Intraoperative MER did not increase the overall risk of hemorrhage in the authors' experience using primarily a single MER trajectory and a guiding cannula.

9.
Brain Commun ; 5(6): fcad268, 2023.
Article in English | MEDLINE | ID: mdl-38025270

ABSTRACT

Subthalamic nucleus deep brain stimulation is commonly indicated for symptomatic relief of idiopathic Parkinson's disease. Despite the known improvement in motor scores, affective, cognitive, voice and speech functions might deteriorate following this procedure. Recent studies have correlated motor outcomes with intraoperative microelectrode recordings. However, there are no microelectrode recording-based tools with predictive values relating to long-term outcomes of integrative motor and non-motor symptoms. We conducted a retrospective analysis of the outcomes of patients with idiopathic Parkinson's disease who had subthalamic nucleus deep brain stimulation at Tel Aviv Sourasky Medical Centre (Tel Aviv, Israel) during 2015-2016. Forty-eight patients (19 women, 29 men; mean age, 58 ± 8 years) who were implanted with a subthalamic nucleus deep brain stimulation device underwent pre- and postsurgical assessments of motor, neuropsychological, voice and speech symptoms. Significant improvements in all motor symptoms (except axial signs) and levodopa equivalent daily dose were noted in all patients. Mild improvements were observed in more posterior-related neuropsychological functions (verbal memory, visual memory and organization) while mild deterioration was observed in frontal functions (personality changes, executive functioning and verbal fluency). The concomitant decline in speech intelligibility was mild and only partial, probably in accordance with the neuropsychological verbal fluency results. Acoustic characteristics were the least affected and remained within normal values. Dimensionality reduction of motor, neuropsychological and voice scores rendered six principal components that reflect the main clinical aspects: the tremor-dominant versus the rigidity-bradykinesia-dominant motor symptoms, frontal versus posterior neuropsychological deficits and acoustic characteristics versus speech intelligibility abnormalities. Microelectrode recordings of subthalamic nucleus spiking activity were analysed off-line and correlated with the original scores and with the principal component results. Based on 198 microelectrode recording trajectories, we suggest an intraoperative subthalamic nucleus deep brain stimulation score, which is a simple sum of three microelectrode recording properties: normalized neuronal activity, the subthalamic nucleus width and the relative proportion of the subthalamic nucleus dorsolateral oscillatory region. A threshold subthalamic nucleus deep brain stimulation score >2.5 (preferentially composed of normalized root mean square >1.5, subthalamic nucleus width >3 mm and a dorsolateral oscillatory region/subthalamic nucleus width ratio >1/3) predicts better motor and non-motor long-term outcomes. The algorithm presented here optimizes intraoperative decision-making of deep brain stimulation contact localization based on microelectrode recording with the aim of improving long-term (>1 year) motor, neuropsychological and voice symptoms.

10.
Front Aging Neurosci ; 15: 1185348, 2023.
Article in English | MEDLINE | ID: mdl-37700815

ABSTRACT

Background: It is well known that motor features of Parkinson's disease (PD) commonly begin on one side of the body and extend to the other side with disease progression. The onset side generally remains more severely affected over the course of the disease. However, the pathophysiology underlying the asymmetry of motor manifestations remains unclear. The purpose of the present study is to examine whether alterations in neuronal activity in the subthalamic nucleus (STN) associate with PD severity. Methods: Microelectrode recording was performed in the STN during targeting for 30 patients in the treatment of deep brain stimulation. The mean spontaneous firing rate (MSFR), power density spectral analysis, and correlations were calculated. Characteristics of subthalamic oscillatory activity were compared between two hemispheres. UPDRS III scores during "Off" and "On" states were obtained for the body side of initial symptoms (BSIS) and the body side of extended symptoms (BSES). Results: There were significant differences of MSFR (41.3 ± 11.0 Hz vs 35.2 ± 10.0 Hz) and percentage of ß frequency oscillatory neurons (51.3% vs 34.9%) between BSIS and BSES. The percentage of ß frequency oscillatory neurons correlated with the bradykinesia/rigidity scores for both sides (p < 0.05). In contrast, the percentage of tremor frequency oscillatory neurons was significantly higher in the BSES than that in the BSIS. In particular, these neurons only correlated with the tremor scores of the BSES (p < 0.05). Conclusion: The results suggest that increased neuronal firing rate and ß frequency oscillatory neurons in the STN are associated with contralateral side motor severity and its progression. Tremor frequency oscillatory neurons are less observed in the STN of the BSIS suggesting that ß oscillatory activity dominates and tremor frequency oscillatory activity reciprocally declines.

11.
Neurocirugía (Soc. Luso-Esp. Neurocir.) ; 34(4): 186-193, jul.- ago. 2023. ilus, tab, graf
Article in English | IBECS | ID: ibc-223510

ABSTRACT

Introduction and objectives Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a recognized treatment for drug-refractory Parkinson's disease (PD). However, the therapeutic success depends on the accuracy of targeting. This study aimed to evaluate potential accuracy differences in the placement of the first and second electrodes implanted, by comparing chosen electrode trajectories, STN activity detected during microelectrode recording (MER), and the mismatch between the initially planned and final electrode positions on each side. Materials and methods In this retrospective cohort study, we analyzed data from 30 patients who underwent one-stage bilateral DBS. For most patients, three arrays of microelectrodes were used to determine the physiological location of the STN. Final target location depended also on the results of intraoperative stimulation. The choice of central versus non-central channels was compared. The Euclidean vector deviation was calculated using the initially planned coordinates and the final position of the tip of the electrode according to a CT scan taken at least a month after the surgery. Results The central channel was chosen in 70% of cases on the first side and 40% of cases on the second side. The mean length of high-quality STN activity recorded in the central channel was longer on the first side than the second (3.07±1.85mm vs. 2.75±1.94mm), while in the anterior channel there were better MER recordings on the second side (1.59±2.07mm on the first side vs. 2.78±2.14mm on the second). Regarding the mismatch between planned versus final electrode position, electrodes on the first side were placed on average 0.178±0.917mm lateral, 0.126±1.10mm posterior and 1.48±1.64mm inferior to the planned target (AU)


Introducción y objetivos La estimulación cerebral profunda (ECP) del núcleo subtalámico (NST) es reconocida como un tratamiento para la enfermedad de Parkinson (EP) refractaria al tratamiento farmacológico. Sin embargo, el éxito de esta intervención depende de la precisión de la colocación de los electrodos. Este estudio tuvo como objetivo evaluar las posibles diferencias de precisión entre la colocación del primer y segundo electrodo, comparando las trayectorias elegidas para cada lado, la actividad del NST detectada durante el microrregistro (MER) y la discrepancia entre las posiciones inicialmente planeadas y las finales. Materiales y métodos En este estudio retrospectivo analizamos datos de 30 pacientes sometidos a ECP bilateral. En la mayoría de los casos se usaron tres conjuntos de microelectrodos para determinar la ubicación fisiológica del NST. El posicionamiento final del electrodo estuvo asimismo condicionado por los resultados de la estimulación intraoperatoria. Se comparó la elección de canales centrales vs. no centrales. El vector euclidiano del desvío se calculó a partir de las coordenadas planeadas inicialmente y la posición final de la punta del electrodo, según una tomografía computarizada realizada al menos un mes después de la cirugía. Resultados La trayectoria central se eligió en 70% de los casos en el primer lado y en el 40% de los casos en el segundo lado. La duración media de la actividad de alta calidad del NST registrada en el canal central fue mayor en el primer lado que en el segundo (3,07±1,85mm vs. 2,75±1,94mm), mientras que en el canal anterior hubo mejores registros de MER en el segundo lado (1,59±2,07mm en el primer lado vs. 2,78±2,14mm en el segundo) (AU)


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Deep Brain Stimulation/methods , Parkinson Disease/therapy , Subthalamic Nucleus , Tomography, X-Ray Computed , Retrospective Studies , Electrodes, Implanted , Microelectrodes
12.
Front Aging Neurosci ; 15: 1114466, 2023.
Article in English | MEDLINE | ID: mdl-36875708

ABSTRACT

Objectives: Low-beta oscillation (13-20 Hz) has rarely been studied in patients with early-onset Parkinson's disease (EOPD, age of onset ≤50 years). We aimed to explore the characteristics of low-beta oscillation in the subthalamic nucleus (STN) of patients with EOPD and investigate the differences between EOPD and late-onset Parkinson's disease (LOPD). Methods: We enrolled 31 EOPD and 31 LOPD patients, who were matched using propensity score matching. Patients underwent bilateral STN deep brain stimulation (DBS). Local field potentials were recorded using intraoperative microelectrode recording. We analyzed the low-beta band parameters, including aperiodic/periodic components, beta burst, and phase-amplitude coupling. We compared low-beta band activity between EOPD and LOPD. Correlation analyses were performed between the low-beta parameters and clinical assessment results for each group. Results: We found that the EOPD group had lower aperiodic parameters, including offset (p = 0.010) and exponent (p = 0.047). Low-beta burst analysis showed that EOPD patients had significantly higher average burst amplitude (p = 0.016) and longer average burst duration (p = 0.011). Furthermore, EOPD had higher proportion of long burst (500-650 ms, p = 0.008), while LOPD had higher proportion of short burst (200-350 ms, p = 0.007). There was a significant difference in phase-amplitude coupling values between low-beta phase and fast high frequency oscillation (300-460 Hz) amplitude (p = 0.019). Conclusion: We found that low-beta activity in the STN of patients with EOPD had characteristics that varied when compared with LOPD, and provided electrophysiological evidence for different pathological mechanisms between the two types of PD. These differences need to be considered when applying adaptive DBS on patients of different ages.

13.
Front Neurol ; 14: 1117681, 2023.
Article in English | MEDLINE | ID: mdl-36908617

ABSTRACT

Objective: Microelectrode recording (MER) guided subthalamic nucleus deep brain stimulation (STN-DBS) under local anesthesia (LA) is widely applied in the management of advanced Parkinson's disease (PD). Whereas, awake DBS under LA is painful and burdensome for PD patients. We analyzed the influence of general anesthesia (GA) on intraoperative MER, to assess the feasibility and effectiveness of GA in MER guided STN-DBS. Methods: Retrospective analysis was performed on the PD patients, who underwent bilateral MER guided STN-DBS in Wuhan Union Hospital from July 2019 to December 2021. The patients were assigned to LA or GA group according to the anesthetic methods implemented. Multidimensional parameters, including MER signals, electrode implantation accuracy, clinical outcome and adverse events, were analyzed. Results: A total of 40 PD patients were enrolled in this study, including 18 in LA group and 22 in GA group. There were no statistically significant differences in patient demographics and baseline characteristics between two groups. Although, the parameters of MER signal, including frequency, inter-spike interval (ISI) and amplitude, were obviously interfered under GA, the waveforms of MER signals were recognizable and shared similar characteristics with LA group. Both LA and GA could achieve effective electrode implantation accuracy and clinical outcome. They also shared similar adverse events postoperatively. Conclusion: GA is viable and comparable to LA in MER guided STN-DBS for PD, regarding electrode implantation accuracy, clinical outcome and adverse events. Notably, GA is more friendly and acceptable to the patients who are incapable of enduring intraoperative MER under LA.

14.
Stereotact Funct Neurosurg ; 101(3): 161-169, 2023.
Article in English | MEDLINE | ID: mdl-36996782

ABSTRACT

INTRODUCTION: Intraoperative microelectrodes recording with the Ben Gun microdrive system are often used during DBS surgery. An accurate location of these microelectrodes will directly influence the interest of this recording. We have studied the imprecision of implantation of these microelectrodes. METHODS: We have analyzed the stereotactic position of 135 microelectrodes implanted with the Ben Gun microdrive during DBS surgery of 16 patients with advanced Parkinson's disease. An intracranial CT was obtained and integrated to a stereotactic planification system. We recorded the stereotactic coordinates of the 5 microelectrodes inserted simultaneously in a cross-shape. The coordinates of each microelectrode were compared with coordinates of the other 4 electrodes inserted simultaneously with the Ben Gun and visible on the same iCT image. Thus, this procedure avoids errors from image fusion and from brain shift. We calculate (1) the three-dimensional Euclidian deviation of microelectrodes, (2) the deviation in X- and Y-axes on reconstructed probe's eye view MR images, and (3) the deviation from the 2-mm theoretical distance between the central electrode and 4 satellite microelectrodes. RESULTS: The median deviation was 0.64 mm in 3-D and 0.58 mm in 2-D probe's eye view. Satellite electrodes were located from the central electrode theoretically at 2.0 mm and practically within the range 1.9-2.1 mm, 1.5-2.5 mm, 1.0-3.0 mm, and 0.5-3.5 mm for, respectively, 9.3%, 53.7%, 88.0%, and 98.1%, thus highlighting the significant deviation from the theoretical distance. Position imprecisions were similar for the 4 satellite microelectrodes. The imprecision was similar in X-axis and Y-axes and statistically less in Z-axis. For bilateral implantation, the second implantation of the same patient was not associated with a greater risk of deviation of the microelectrodes than for the first side implanted. CONCLUSION: A significant percentage of microelectrodes for MER can deviate substantially from their theoretical target during DBS procedures. An iCT can be used to estimate the potential deviation of microelectrodes and improve the interpretation of MER during the procedure.


Subject(s)
Deep Brain Stimulation , Parkinson Disease , Subthalamic Nucleus , Humans , Microelectrodes , Deep Brain Stimulation/methods , Parkinson Disease/diagnostic imaging , Parkinson Disease/surgery , Subthalamic Nucleus/surgery , Tomography, X-Ray Computed/methods , Electrodes, Implanted , Magnetic Resonance Imaging
15.
Neurocirugia (Astur : Engl Ed) ; 34(4): 186-193, 2023.
Article in English | MEDLINE | ID: mdl-36775743

ABSTRACT

INTRODUCTION AND OBJECTIVES: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a recognized treatment for drug-refractory Parkinson's disease (PD). However, the therapeutic success depends on the accuracy of targeting. This study aimed to evaluate potential accuracy differences in the placement of the first and second electrodes implanted, by comparing chosen electrode trajectories, STN activity detected during microelectrode recording (MER), and the mismatch between the initially planned and final electrode positions on each side. MATERIALS AND METHODS: In this retrospective cohort study, we analyzed data from 30 patients who underwent one-stage bilateral DBS. For most patients, three arrays of microelectrodes were used to determine the physiological location of the STN. Final target location depended also on the results of intraoperative stimulation. The choice of central versus non-central channels was compared. The Euclidean vector deviation was calculated using the initially planned coordinates and the final position of the tip of the electrode according to a CT scan taken at least a month after the surgery. RESULTS: The central channel was chosen in 70% of cases on the first side and 40% of cases on the second side. The mean length of high-quality STN activity recorded in the central channel was longer on the first side than the second (3.07±1.85mm vs. 2.75±1.94mm), while in the anterior channel there were better MER recordings on the second side (1.59±2.07mm on the first side vs. 2.78±2.14mm on the second). Regarding the mismatch between planned versus final electrode position, electrodes on the first side were placed on average 0.178±0.917mm lateral, 0.126±1.10mm posterior and 1.48±1.64mm inferior to the planned target, while the electrodes placed on the second side were 0.251±1.08mm medial, 0.355±1.29mm anterior and 2.26±1.47mm inferior to the planned target. CONCLUSION: There was a tendency for the anterior trajectory to be chosen more frequently than the central on the second side. There was also a statistically significant deviation of the second electrodes in the anterior and inferior directions, when compared to the electrodes on the first side, suggesting that another cause other than brain shift may be responsible. We should therefore factor this during planning for the second implanted side. It might be useful to plan the second side more anteriorly, possibly reducing the number of MER trajectories tested and the duration of surgery.


Subject(s)
Deep Brain Stimulation , Subthalamic Nucleus , Humans , Subthalamic Nucleus/physiology , Subthalamic Nucleus/surgery , Deep Brain Stimulation/methods , Retrospective Studies , Electrodes, Implanted , Microelectrodes
16.
J Neural Eng ; 20(1)2023 02 27.
Article in English | MEDLINE | ID: mdl-36763997

ABSTRACT

Objective. Suboptimal electrode placement during subthalamic nucleus deep brain stimulation (STN DBS) surgery may arise from several sources, including frame-based targeting errors and intraoperative brain shift. We present a computer algorithm that can accurately localize intraoperative microelectrode recording (MER) tracks on preoperative magnetic resonance imaging (MRI) in real-time, thereby predicting deviation between the surgical plan and the MER trajectories.Approach. Random forest (RF) modeling was used to derive a statistical relationship between electrophysiological features on intraoperative MER and voxel intensity on preoperative T2-weighted MR imaging. This model was integrated into a larger algorithm that can automatically localize intraoperative MER recording tracks on preoperative MRI in real-time. To verify accuracy, targeting error of both the planned intraoperative trajectory ('planned') and the algorithm-derived trajectory ('calculated') was estimated by measuring deviation from the final DBS lead location on postoperative high-resolution computed tomography ('actual').Main results. MR imaging and MERs were obtained from 24 STN DBS implant trajectories. The cross-validated RF model could accurately distinguish between gray and white matter regions along MER trajectories (AUC 0.84). When applying this model within the localization algorithm, thecalculatedMER trajectory estimate was found to be significantly closer to theactualDBS lead when compared to theplannedtrajectory recorded during surgery (1.04 mm vs 1.52 mm deviation,p< 0.002), with improvement shown in 19/24 cases (79%). When applying the algorithm to simulated DBS trajectory plans with randomized targeting error, up to 4 mm of error could be resolved to <2 mm on average (p< 0.0001).Significance. This work presents an automated system for intraoperative localization of electrodes during STN DBS surgery. This neuroengineering solution may enhance the accuracy of electrode position estimation, particularly in cases where high-resolution intraoperative imaging is not available.


Subject(s)
Deep Brain Stimulation , Subthalamic Nucleus , Deep Brain Stimulation/methods , Microelectrodes , Electrodes, Implanted , Magnetic Resonance Imaging/methods , Subthalamic Nucleus/physiology
17.
Front Neurosci ; 16: 988661, 2022.
Article in English | MEDLINE | ID: mdl-36408391

ABSTRACT

Background: The accuracy of the deep brain stimulation (DBS) electrode placement is influenced by a myriad of factors, among which pneumocephalus and loss of cerebrospinal fluid that occurs with dural opening during the surgery are considered most important. This study aimed to describe an effective method for decreasing pneumocephalus by comparing its clinical efficacy between the two different methods of opening the dura. Materials and methods: We retrospectively compared two different methods of opening the dura in 108 patients who underwent bilateral DBS surgery in our center. The dural incision group comprised 125 hemispheres (58 bilateral and 9 unilateral) and the dural puncture group comprised 91 (41 bilateral and 9 unilateral). The volume of intracranial air, dural opening time, intraoperative microelectrode recordings (MERs), postoperative electrode displacement, clinical efficacy, and complications were examined. Spearman correlation analysis was employed to identify factors associated with the volume of intracranial air and postoperative electrode displacement. Results: The volume of intracranial air was significantly lower (0.35 cm3 vs. 5.90 cm3) and dural opening time was significantly shorter (11s vs. 35s) in the dural puncture group. The volume of intracranial air positively correlated with dural opening time. During surgery, the sensorimotor area was longer (2.47 ± 1.36 mm vs. 1.92 ± 1.42 mm) and MERs were more stable (81.82% vs. 47.73%) in the dural puncture group. Length of the sensorimotor area correlated negatively with the volume of intracranial air. As intracranial air was absorbed after surgery, significant anterior, lateral, and ventral electrode displacement occurred; the differences between the two groups were significant (total electrode displacement, 1.0mm vs. 1.4mm). Electrode displacement correlated positively with the volume of intracranial air. Clinical efficacy was better in the dural puncture group than the dural incision group (52.37% ± 16.18% vs. 43.93% ± 24.50%), although the difference was not significant. Conclusion: Our data support the hypothesis that opening the dura via puncture rather than incision when performing DBS surgery reduces pneumocephalus, shortens dural opening time, enables longer sensorimotor area and more stable MERs, minimizes postoperative electrode displacement, and may permit a better clinical efficacy.

18.
Brain Sci ; 12(11)2022 Oct 29.
Article in English | MEDLINE | ID: mdl-36358395

ABSTRACT

Our objective is to analyze the difference of microelectrode recording (MER) during awake and asleep subthalamic nucleus deep brain stimulation (STN-DBS) for Parkinson's disease (PD) and the necessity of MER during "Asleep DBS" under general anesthesia (GA). The differences in MER, target accuracy, and prognosis under different anesthesia methods were analyzed. Additionally, the MER length was compared with the postoperative electrode length by electrode reconstruction and measurement. The MER length of two groups was 5.48 ± 1.39 mm in the local anesthesia (LA) group and 4.38 ± 1.43 mm in the GA group, with a statistical significance between the two groups (p < 0.01). The MER length of the LA group was longer than its postoperative electrode length (p < 0.01), however, there was no significant difference between the MER length and postoperative electrode length in the GA group (p = 0.61). There were also no significant differences in the postoperative electrode length, target accuracy, and postoperative primary and secondary outcome scores between the two groups (p > 0.05). These results demonstrate that "Asleep DBS" under GA is comparable to "Awake DBS" under LA. GA has influences on MER during surgery, but typical STN discharges can still be recorded. MER is not an unnecessary surgical procedure.

19.
Cureus ; 14(8): e27887, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36110462

ABSTRACT

Parkinson's disease (PD) is a neurological disorder in which nigrostriatal pathways involving the basal ganglia experience a decrease in neural activity regarding dopaminergic neurons. PD symptoms, such as muscle stiffness and involuntary tremors, have an adverse impact on the daily lives of those affected. Current medical treatments seek to decrease the severity of these symptoms. Deep brain stimulation (DBS) has become the preferred safe, and reliable treatment approach. DBS involves implanting microelectrodes into subcortical areas that produce electrical impulses directly to high populations of dopaminergic neurons. The most common targets are the subthalamic nucleus (STN), and the basal ganglia's globus pallidus pars interna (GPi). Research studies suggest that DBS of the STN may cause a significant reduction in the daily dose of L-DOPA compared to DBS of the GPi. DBS of the STN has suggested that there may be sweet spots within the STN that provide hyper-direct cortical connectivity pathways to the primary motor cortex (M1), supplementary motor area (SMA), and prefrontal cortex (PFC). In addition, the pedunculopontine nucleus (PPN) may be a new target for DBS that helps treat locomotion problems associated with gait and posture. Both microelectrode recording (MER) and magnetic resonance imaging (MRI) are used to ensure electrode placement accuracy. Using MER, stimulation of the STN at high frequencies (140<) decreased oscillatory neuronal firing by 67%. This paper investigates methods of intraoperative neuromonitoring during DBS as a form of PD treatment.

20.
J Parkinsons Dis ; 12(7): 2059-2069, 2022.
Article in English | MEDLINE | ID: mdl-35912752

ABSTRACT

BACKGROUND: STN-DBS is a cornerstone in the treatment of advanced Parkinson's disease (PD). The traditional approach is to use an awake operative technique with microelectrode recording (MER). However, more centers start using an asleep MRI-guided technique without MER. OBJECTIVE: We systematically reviewed the literature to compare STN-DBS surgery with and without MER for differences in clinical outcome. METHODS: We systematically searched PubMed, Embase, MEDLINE, and Web of Science databases for randomized clinical trials and consecutive cohort studies published between 01-01-2000 and 26-08-2021, that included at least 10 PD patients who had received bilateral STN-DBS. RESULTS: 2,129 articles were identified. After abstract screening and full-text review, 26 studies were included in the final analysis, comprising a total of 34 study groups (29 MER and 5 non-MER). The standardized mean difference (SMD) in change in motor symptoms between baseline (OFF medication) and 6-24 months follow-up (OFF medication and ON stimulation) was 1.64 for the MER group and 1.87 for non-MER group (p = 0.59). SMD in change in levodopa equivalent daily dose (LEDD) was 1.14 for the MER group and 0.65 for non-MER group (p < 0.01). Insufficient data were available for comparative analysis of PDQ-39 and complications. CONCLUSION: The change in motor symptoms from baseline to follow-up did not differ between studies that used MER and those that did not. The postoperative reduction in LEDD from baseline to follow-up was greater in the MER-group. In the absence of high-quality studies comparing both methods, there is a clear need for a well-designed comparative trial.


Subject(s)
Deep Brain Stimulation , Parkinson Disease , Subthalamic Nucleus , Deep Brain Stimulation/methods , Humans , Levodopa/therapeutic use , Microelectrodes , Parkinson Disease/drug therapy , Parkinson Disease/surgery , Subthalamic Nucleus/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...