Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 738
Filter
1.
J Contemp Dent Pract ; 25(4): 346-353, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38956850

ABSTRACT

AIM: The aim of the study was to compare and evaluate the microleakage of fiber-reinforced glass ionomer cement (GIC) and conventional glass ionomer cement restorations immersed in three different beverages. MATERIALS AND METHODS: A total of 96 human exfoliating deciduous molars were selected which were cleaned and disinfected. Standardized Class V cavity preparations were done and buccal surface were restored with experimental fiber-reinforced glass ionomer cement (Exp-FRGIC), lingual surface were restored with Type II conventional GIC. They were divided into four groups according to the test beverage. The samples were subjected to various immersion regimes and evaluated for microleakage under stereomicroscope. RESULTS: Intragroup comparison for (Exp-FRGIC) showed significant microleakage when immersed in fresh fruit juice at high immersion whereas intragroup comparison in conventional GIC, showed highest microleakage with soft drink. Intergroup comparison of (Exp-FRGIC) in high immersion regime, showed more microleakage with specimen immersed in soft drink followed by fresh fruit juice. CONCLUSION: It can thus be concluded that the three beverages used in the study affected the microleakage of both restorative materials significantly. CLINICAL SIGNIFICANCE: Increasing usage of fruit juices in the pediatric diet has a definite impact on the progression of caries and it directly or indirectly affects the quality of restorations placed in the oral cavity. How to cite this article: George MA, Chandak SA, Khekade SH, et al. Comparative Evaluation of Microleakage of Fiber-reinforced Glass Ionomer Cement and Conventional Glass Ionomer Cement Restorations Immersed in Three Different Beverages: In Vitro Study. J Contemp Dent Pract 2024;25(4):346-353.


Subject(s)
Dental Leakage , Dental Restoration, Permanent , Glass Ionomer Cements , Glass Ionomer Cements/chemistry , Humans , Dental Restoration, Permanent/methods , In Vitro Techniques , Beverages , Materials Testing , Fruit and Vegetable Juices , Molar , Tooth, Deciduous
2.
J Contemp Dent Pract ; 25(4): 335-341, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38956848

ABSTRACT

AIM OF THE STUDY: The study aimed to assess the microleakage of nanoparticle-based (NPB) cyanoacrylate sealer and epoxy resin-based (ERB) sealer using radioisotope method and confocal laser scanning microscopy (CLSM). MATERIALS AND METHODS: A total of 100 single-rooted teeth were collected; specimens were accessed, instrumented, and irrigated, and randomly distributed into 4 groups of 25 samples each: Group I: Positive control, group II: Negative control, group III: Obturated with NPB sealer, and group IV: Obturated with ERB sealer. All samples were immersed in 99mTc pertechnetate solution, for 3 hours after which radioactivity was estimated under a Gamma camera. The radioactivity released by specimens before and after nail varnish removal was statistically analyzed. After 2 weeks, the same samples were used for CLSM analysis. The sealer tubular penetration depth was measured at the deepest level for each group using ZEN lite 2012. Data collected was statistically evaluated. RESULTS: The amount of radioactivity observed at first in group III and group IV was 194.76 and 599.12 units, respectively, with p-value < 0.001, indicating significant interaction, and after nail varnish removal, it was 89.68 and 468.44 units, respectively, with a p-value < 0.001; again, indicating statistical significance. Hence, the radioactivity of NPB sealer was found to be lower than ERB sealer in both cases, indicating better sealing of the former. The photomicrographs show that mean value of dye penetration in NPB sealer in first, second, and third segment from apex was 85.06, 75.73, and 66.09, respectively; while in the case of ERB sealer, those were 597.28, 461.17, and 195.68, respectively; with p-value < 0.001; signifying that NPB sealer exhibited higher resistance to microleakage than ERB sealer. CONCLUSION: The NPB sealer can become a potential root canal sealer in future endodontics due to superior physiochemical properties attributed to the cyanoacrylate and incorporated nanoparticles. CLINICAL SIGNIFICANCE: The study clinically signifies that we can equally use the radioisotopic method along with confocal method while conducting the microleakage studies. In addition, NPB sealer can be an emerging replacement with better properties than gold standard root canal sealers for clinical use. How to cite this article: Shetty C, Qaiser S, Shetty A, et al. Evaluation of Microleakage of Nanoparticle-incorporated Cyanoacrylate Root Canal Sealer Using the Radioisotopic Method: An In Vitro Study. J Contemp Dent Pract 2024;25(4):335-341.


Subject(s)
Dental Leakage , Epoxy Resins , Microscopy, Confocal , Nanoparticles , Root Canal Filling Materials , Dental Leakage/prevention & control , Root Canal Filling Materials/chemistry , Humans , In Vitro Techniques , Cyanoacrylates , Root Canal Obturation/methods , Sodium Pertechnetate Tc 99m , Materials Testing
3.
Bioinformation ; 20(4): 319-322, 2024.
Article in English | MEDLINE | ID: mdl-38854762

ABSTRACT

A preferable choice of material offers superior resistance against micro-leakage for clinical applications in preventing dental caries in pits and fissures is of interest. A total of 45 extracted human premolars were cleaned, stored in a saline solution, and randomly divided into three groups, each intended for treatment with one of the sealants: Fuzi VII, ClinPro, and Embrace Wetbond. The application of the sealants followed the manufacturers' instructions strictly. The teeth were subjected to thermal cycling to simulate oral conditions. Marginal micro-leakage was then assessed by dye penetration method using a 0.5% methylene blue dye. Teeth were sectioned, and dye penetration was measured under a stereomicroscope. The results showed that all the tested materials exhibited some degree of micro-leakage. Within the limitations of this In vitro study, it was concluded that Embrace Wetbond exhibited superior performance in terms of minimizing marginal micro-leakage among the tested pit and fissure sealants.

4.
J Int Soc Prev Community Dent ; 14(2): 121-128, 2024.
Article in English | MEDLINE | ID: mdl-38827349

ABSTRACT

Aim: To determine whether rinsing with preprocedural mouthrinses against coronavirus disease before acid etching affects resin-based sealant microleakage. Materials and Methods: A presented in vitro experimental study was performed on 15 extracted permanent third molars. Samples were randomly allocated into five groups: Group 1-distilled water (control); Group 2-1% hydrogen peroxide; Group 3-1.5% hydrogen peroxide; Group 4-0.5% povidone-iodine; and Group 5-1% povidone-iodine. After the teeth were immersed in the assigned mouth rinses for 60 s, they were sealed with Concise™ white sealant. Subsequently, the teeth were thermocycled for 500 cycles, immersed in 2% methylene blue solution for 24 h, and sectioned with two parallel cuts in the buccolingual direction. Sixty surfaces (12 surfaces in each group) were examined for microleakage under a 40× light microscope and scored as described by Zyskind et al. Welch's one-way analysis of variance test and the Games-Howell test were used to analyze the results at a significance level of P < 0.05 for all tests. Results: The intergroup comparisons indicated that the 0.5% povidone-iodine group and the 1% povidone-iodine group had significantly higher microleakage compared with the control group. The 1% and 1.5% hydrogen peroxide groups demonstrated no significant difference in mean microleakage scores compared with the control group. There was no significant difference between the povidone groups and the hydrogen peroxide groups. Conclusions: Preprocedural rinsing with 0.5% and 1% povidone-iodine before acid etching caused higher microleakage of resin-based sealant, while hydrogen peroxide rinsing gave comparable microleakage compared with the control group.

5.
J Conserv Dent Endod ; 27(5): 529-534, 2024 May.
Article in English | MEDLINE | ID: mdl-38939536

ABSTRACT

Aim: This study aims to evaluate the microleakage between the gingival seat and base material and to assess the interface integrity between the base material and overlying composite in class II cavities restored using deep margin elevation. Materials and Methods: Thirty maxillary molars (n = 30) were taken, and class II cavities were prepared with a gingival seat extending below the cementoenamel junction. These teeth were divided into three groups for subgingival margin elevation using different materials: Group A (n = 10) - flowable composite, Group B (n = 10) - glass ionomer cement (GIC), and Group C (n = 10) - GIC with nanohydroxyapatite (GIC n-HAp). The remaining cavities were restored with bulk-fill composite. After undergoing 1000 thermocycling cycles, half of the samples were examined for microleakage using confocal laser microscopy, and the other half were assessed for interface integrity using scanning electron microscopy. Microleakage was statistically analyzed by one-way ANOVA, and interface integrity was analyzed by Kruskal-Wallis tests. Results: The study found that GIC n-HAp exhibited significantly lower microleakage between the base material and gingival seat than flowable composite and GIC. However, regarding interface integrity between the base material and bulk-fill composite, flowable composite, and GIC outperformed GIC n-HAp. Conclusions: Incorporating n-HAp into GIC effectively reduced microleakage at the dentin-base material interface. However, the interface integrity between GIC n-HAp and the composite poses a challenge.

6.
BMC Oral Health ; 24(1): 546, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730400

ABSTRACT

BACKGROUND: Recently, a new generation of high-strength flowable dental composites has been introduced by manufacturers. The manufacturers claim that these materials have enhanced mechanical and physical properties and are suitable for use in a wide range of direct anterior and posterior restorations, even in high-stress bearing areas. AIM: The objective of this study was to assess certain physical and mechanical properties of these recently introduced high-strength flowable composites in comparison to conventional multipurpose dental composites. METHODS: Four types of high-strength flowable composites (Genial Universal FLO, Gaenial Universal Injectable, Beautifil Injectable, and Beautifil Flow Plus) were tested in experimental groups, while a nanohybrid conventional composite (Filtek Z350 XT) was used as the control. For flexure properties, ten rectangular samples (2 × 2 × 25 mm) were prepared from each composite material and subjected to 5000 cycles of thermocycling. Samples were then subjected to flexural strength testing using the universal testing machine. Another twenty disc-shaped specimens of dimensions (5 mm diameter × 2 mm thickness) were fabricated from each composite material for surface roughness (Ra) (n = 10) and hardness (VHN) test (n = 10). All samples underwent 5000 cycles of thermocycling before testing. Additionally, microleakage testing was conducted on 60 standardized class V cavities prepared on molar teeth and divided randomly into five groups (n = 12). Cavities were then filled with composite according to the manufacturer's instructions and subjected to thermocycling for 1000 cycles before testing using methylene blue solution and a stereomicroscope. RESULTS: All tested materials were comparable to the control group in terms of flexural strength and surface roughness (p > 0.05), with Gaenial Universal FLO exhibiting significantly higher flexural strength compared to the other flowable composite materials tested. However, all tested materials demonstrated significantly lower elastic modulus and surface hardness than the control group (p < 0.05). The control group exhibited higher microleakage scores, while the lowest scores were observed in the Gaenial Universal FLO material (p < 0.05) CONCLUSION: The physical and mechanical behaviors of the different high-strength flowable composites investigated in this study varied. Some of these materials may serve as suitable alternatives to conventional composites in specific applications, emphasizing the importance of dentists being familiar with material properties before making material selections.


Subject(s)
Composite Resins , Dental Leakage , Flexural Strength , Hardness , Materials Testing , Surface Properties , In Vitro Techniques , Humans , Dental Stress Analysis , Dental Materials/chemistry , Stress, Mechanical , Polyethylene Glycols , Polymethacrylic Acids/chemistry , Bisphenol A-Glycidyl Methacrylate
7.
J Pharm Bioallied Sci ; 16(Suppl 1): S162-S164, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38595365

ABSTRACT

Introduction: Indirect composite restoration is one of the commonly followed procedures in the posterior teeth. The success of this is dependent on many factors, one being the luting cement. Hence, the current study explores the microleakage of the two luting cements at 2 different times. Materials and Methods: Eighty extracted human teeth were taken, and class II cavities were made that were to receive the composite inlays. They were grouped as supragingival and subgingival, which for further divided as were further subdivided to be observed for marginal leakage at cervical and occlusal margins, at the end of a day and 1 month. Each group had ten specimens. The luting cements that were evaluated were Variolink N and RelyX Unicem. After the composite inlay restoration was done for all the specimens, the sections were put on slides, and a stereomicroscope was used to measure the amount of dye penetration. Leakage was evaluated and compared using Mann-Whitney U test. Results: At the end of 1 day, there was no significant alteration in the microleakage in the occlusal or cervical regions for either region supragingivally or subgingivally between the two luting cements. Significant difference between the two cements at the cervical borders at the end of a month was seen for both the margins. When compared supragingivally and subgingivally at the end of 1 day or at the end of 1 month, there was not a significant difference for any of the cements. Conclusion: Within the constraints of the current investigation, it can be said that there was similar microleakage for both Variolink N and RelyX Unicem at the conclusion of a day's storage time. After a 1-month storage period, RelyX Unicem showed more cervical microleakage than Variolink N.

8.
J Pharm Bioallied Sci ; 16(Suppl 1): S254-S257, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38595510

ABSTRACT

Background: Maxillary molar endodontic treatments require the right post and core system. This study tested cast metal, glass fiber with composite resin, carbon fiber with composite resin, and zirconia post and core materials. Materials and Methods: Sixty removed human maxillary teeth were randomly divided into four post and core material groups (n = 15 per group). The teeth acquired their post and core system after normal endodontic treatment. Fracture resistance, cyclic fatigue resistance, and microleakage analyses were statistically assessed. Results: The zirconia post and core material had the highest fracture resistance (mean: 900 N), followed by carbon fiber with composite resin, cast metal, and glass fiber with composite resin. Zirconia had the highest mean cycles to failure (120,000), followed by carbon fiber with composite resin (100,000), cast metal (110,000), and glass fiber with composite resin (90,000). Zirconia had the lowest mean microleakage score (1.8), and glass fiber with composite resin, the highest (3.0). Conclusion: The zirconia post and core material outperformed the others in fracture resistance, cyclic fatigue resistance, and sealing. The cast metal has better fracture and cycle fatigue resistance than glass fiber with composite resin. These findings help doctors choose maxillary molar endodontic post and core materials.

9.
J Pharm Bioallied Sci ; 16(Suppl 1): S733-S735, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38595555

ABSTRACT

Background: Different obturation techniques are being used to improve canal sealing, thereby minimizing marginal leakage. Aims and Objectives: To evaluate the marginal leakage of three different obturating materials and techniques using stereomicroscope. Materials and Methods: Thirty freshly extracted maxillary anterior teeth were collected and were divided into three groups of 10 each for which the biomechanical preparation was done. The teeth were divided into three experimental groups according to the obturation material and technique used, Group I: gutta-percha with AH Plus root canal sealer (lateral condensation): Group II: thermoplasticized gutta-percha technique-non-carrier-based (calamus) with AH Plus sealer (backfill): Group III: C point (self-sealing root canal obturating system) with bioceramic sealer (single cone). Each specimen was subjected for testing apical sealing ability. The values of microleakage associated with different root canal sealers were evaluated using a stereomicroscope. Results: There was no statistically significant difference in the mean scores of apical dye penetration/leakage among all the three groups (P = 0.091), whereas Group I showed a higher degree of apical leakage than the other techniques tested. Conclusion: None of the tested filling materials provided a gap-free or void-free root canal filling; however, thermoplasticized gutta-percha is used with AH Plus sealer exhibited less voids and gaps when compared to other tested materials.

10.
Microsc Res Tech ; 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38661299

ABSTRACT

This research was aimed to evaluate push-out bond strength and apical-microleakage after application of three different calcium silicate-based cements with irrigation solutions on simulated immature teeth. 40 maxillary permanent canine teeth were used for push-out bond strength test, and 120 maxillary permanent incisors were used for microleakage evaluation. 120 root slices were divided into four main groups (EDTA, Chitosan, Phytic acid, and Saline) and immersed these solutiouns according to irrigation procedures. Each irrigation group was divided into 3 subgroups (Biodentine, MTA Repair HP, and NeoPUTTY). The prepared teeth were divided into four groups according to irrigation procedure for microleakage test. EDTA irrigation with Biodentine group showed highest push-out bond strength value and saline group with Neoputty showed the lowest push-out bond strength value. The highest microleakage value was seen in saline group with MTA Repair HP, while the lowest microleakage value was observed chitosan with Biodentine group. Chitosan and phytic acid solutions can be recommended as an alternative irrigation solution to 17% EDTA in single-session apexification treatment, since they are non-toxic, naturally occurring materials, effectively remove the smear layer, and have a positive effect on bond strength and apical leakage. RESEARCH HIGHLIGHTS: One of the factors affecting the long-term success of root canal treatment is a hermetic seal. Non-hermetic or inadequate filling triggers a chronic inflammatory reaction in periapical tissues, causing fluids to enter the spaces and negatively affecting the success of the treatment. Therefore, this study will help clinicians choose the right biomaterial and irrigation solution that will affect the success of root canal treatment.

11.
Sci Rep ; 14(1): 9066, 2024 04 20.
Article in English | MEDLINE | ID: mdl-38643213

ABSTRACT

This in vitro study aimed to evaluate the feasibility of quantitative light-induced fluorescence (QLF) technology for detecting the presence and severity of microleakage of pit and fissure sealants. The areas of interest (AOIs) were 160 pits and fissures of 40 extracted permanent teeth. Fluorescent images were acquired using a QLF device, and the maximum fluorescence loss ΔFmax of each AOI was analyzed. After staining and cross-sectioning of the teeth, histological dye penetration was scored on a scale of 0 to 3. The relationship between ΔFmax and microleakage depth was analyzed, and the areas under the curve (AUCs) were calculated. The │ΔFmax│ increased as microleakage depth increased. The ΔFmax values of microleakage areas showed a strong significant correlation with the histological scores of dye penetration (r = - 0.72, P = 0.001). AUC analysis showed a high diagnostic accuracy for microleakage depth (AUC = 0.83-0.91). The highest AUC of 0.91 was found when differentiating the outer half microleakage of the sealant (histological score 0 vs. 1-3). QLF technology is effective in assessing the presence and severity of microleakage, suggesting its potential for noninvasive detection and monitoring of sealant microleakage in clinical settings.


Subject(s)
Pit and Fissure Sealants , Quantitative Light-Induced Fluorescence , Research Design , Coloring Agents , Staining and Labeling
12.
Photodiagnosis Photodyn Ther ; 47: 104103, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38677500

ABSTRACT

BACKGROUND: This study used optical coherence tomography (OCT) to observe real-time internal gap formation in both bulk-fill and conventional resin composites. It aimed to provide a quantitative analysis of variations, addressing the inconclusive nature of microleakage assessment caused by differences in testing methods. METHODS: Fifty extracted third molars prepared with Class I cavities, were divided into five groups (n = 10). Conventional resin Filtek Z350 XT (FZX) was applied with a double-layer filling of 2 mm per layer. Bulk-fill resins X-tra fil (XTF), Filtek Bulk Fill Posterior Restorative (FBP), Surefil SDR Flow + (SDR), and Filtek Flowable Restorative (FFR) were applied with a single-layer filling of 4 mm. Real-time OCT imaging was conducted during light curing. Post-curing, the entire sample was OCT-scanned. Following this, ImageJ software was used to measure the gap (G1 %). Subsequently, thermal cycling (TC) (5000 times, 5 °C-55 °C) was applied, followed by OCT scanning to calculate the gap (G2 %) and ΔG%. Data were analyzed using two-way repeated measures ANOVA, Kruskal-Wallis test, and Duncan's test (α=0.05). RESULTS: There was no significant difference in G1 % among the groups (p > 0.05). Following TC, FZX exhibited the highest G2 %, succeeded by FFR, FBP, XTF, and SDR, with SDR demonstrating the lowest G2 % (p < 0.05). FZX showed the highest ΔG% (p < 0.05), while SDR exhibited the lowest ΔG% (p < 0.05). CONCLUSION: OCT proves to be a promising tool for detecting microleakage. TC exerted a more significant negative impact on conventional resin. Surefil SDR Flow + displayed the least microleakage, both before and after TC.


Subject(s)
Composite Resins , Tomography, Optical Coherence , Composite Resins/chemistry , Tomography, Optical Coherence/methods , Humans , Materials Testing , Molar, Third/diagnostic imaging , Methacrylates
13.
Dent Mater J ; 43(3): 346-358, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38583998

ABSTRACT

Conventional resin-based sealants release minimal fluoride ions (F) and lack antibacterial activity. The objectives of this study were to: (1) develop a novel bioactive sealant containing calcium fluoride nanoparticles (nCaF2) and antibacterial dimethylaminohexadecyl methacrylate (DMAHDM), and (2) investigate mechanical performance, F recharge and re-release, microleakage, sealing ability and cytotoxicity. Helioseal F served as commercial control. The initial F release from sealant containing 20% nCaF2 was 25-fold that of Helioseal F. After ion exhaustion and recharge, the F re-release from bioactive sealant did not decrease with increasing number of recharge and re-release cycles. Elastic modulus of new bioactive sealant was 44% higher than Helioseal F. The new sealant had excellent sealing, minimal microleakage, and good cytocompatibility. Hence, the nanostructured sealant had substantial and sustained F release and antibacterial activity, good sealing ability and biocompatibility. The novel bioactive nCaF2 sealant is promising to provide long-term F ions for caries prevention.


Subject(s)
Anti-Bacterial Agents , Calcium Fluoride , Dental Leakage , Materials Testing , Methacrylates , Nanoparticles , Pit and Fissure Sealants , Pit and Fissure Sealants/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Calcium Fluoride/chemistry , Methacrylates/chemistry , Nanoparticles/chemistry , Fluorides/chemistry , Fluorides/pharmacology , Elastic Modulus , Animals , Mice , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Surface Properties , Composite Resins
14.
Dent Mater J ; 43(3): 338-345, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38583994

ABSTRACT

This study aimed to evaluate the bonding performance of self-adhesive flowable resin composites (SARs) to bovine teeth. Three SARs, one experimental, and two commercially available products, were used. The study parameters were shear bond strength (SBS), microleakage, and scanning electron microscopy (SEM) evaluation of bonding interfaces. The SBS of the materials was 14.1-15.1 MPa to enamel, 22.2-23.2 MPa to etched enamel, and 7.4-10.7 MPa to dentin. Specimens with pre-etching showed lower microleakage scores than those without pre-etching. SEM images of the interfaces of the materials showed excellent adaptation regardless of the substrate or etching mode. The study results indicate that enamel pre-etching can improve the bonding performance of SARs.


Subject(s)
Acid Etching, Dental , Composite Resins , Dental Bonding , Dental Enamel , Materials Testing , Microscopy, Electron, Scanning , Shear Strength , Surface Properties , Animals , Cattle , Composite Resins/chemistry , Dental Bonding/methods , Dentin , In Vitro Techniques , Dental Leakage , Dental Stress Analysis
15.
Cureus ; 16(2): e54657, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38523959

ABSTRACT

Aim The aim is to evaluate the degree of dye penetration between a dual-cure and conventional resin cement on its application on the root surface indirect restorations to provide a reference for clinical choice. Materials and methods Ten freshly extracted human maxillary central anteriors were selected and randomly divided into two groups of five each. Teeth were prepared for veneer restoration, and veneers were luted using two groups of cements Calibra veneer cement and Fusion Ultra D/C cement. After they were immersed in methylene blue dye solution for 24 h, the specimens were then sectioned buccolingual into three halves in a parallel vertical plane and measured dye penetration using a stereomicroscope (Zeiss). The data collected was recorded by the dye penetration index (0-4) and statistically analyzed using the IBM SPSS Statistics for Windows, Version 24 (Released 2016; IBM Corp., Armonk, New York, United States). Results It is evident that group 1 (Calibra veneer cement) showed the lowest mean score of 0.43 mm and group 2 (Fusion Ultra D/C) showed a highest mean score of 0.72 mm. Overall, when the two groups were compared for microleakage using SPSS, there was a significant difference among the groups. Conclusion It was determined that both the resin cements evaluated in this study showed microleakage to some level given the limits of the investigation and the findings. To evaluate the dye penetration of microleakage, the Calibra veneer resin cement showed a better marginal adaptability for veneer restoration. Further investigations with broader methodology and more clinical simulation are needed to evaluate other resin cements available for root surface indirect restorations to be analyzed for prospective clinical outcomes.

16.
J Contemp Dent Pract ; 25(1): 3-9, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38514424

ABSTRACT

AIM: This study aimed to evaluate the marginal microleakage and maximum occlusal fracture loads and fracture modes of two novel class II preparation designs, "infinity edge" and the "2.5 mm cusp reduction" preparations as compared to a traditional class II preparation without cuspal involvement. MATERIALS AND METHODS: Thirty extracted human mandibular molars were prepared for moderate-sized class II restorations with extensions into all occlusal grooves. Of these, ten class II preparations served as control. Ten were modified for a 2.5 mm even reduction of the cusps adjacent to the interproximal box. An additional 10 preparations were modified with an "infinity edge" bevel on the interproximal and occlusal portions. All teeth were restored utilizing a flowable bulk-fill composite in the apical portion of the interproximal box and 2-4 mm of heated bulk-fill composite in one increment for the remainder. All groups were cyclic loaded and thermocycled, then imaged with microcomputed tomography (µCT) before and after infiltration with a silver nitrate solution. Images were subtracted to obtain volumetric measurements of microleakage and reported as a percentage of the total volume from the apical extent of the proximal box. All groups were loaded to failure and fracture load and mode were recorded. RESULTS: No significant differences were found in microleakage volume as a percentage of total tooth volume; however, the "infinity edge" group had significantly greater microleakage in the proximal box compared to the traditional class II group. No significant differences were found in fracture load or mode between the groups. CONCLUSION: Traditional class II, 2.5 mm cuspal reduction, and "infinity edge" preparation designs have similar fracture loads as well as volumes of microleakage; however, an "infinity edge" preparation has a higher ratio of microleakage in the proximal box. CLINICAL SIGNIFICANCE: Clinicians should carefully consider the use of "infinity edge" margins, particularly on dentin in the apical extent of the proximal box. How to cite this article: Watson JC, Lien W, Raimondi JC, et al. In Vitro Microleakage and Fracture Resistance of "Infinity Edge" and Cusp Reduction Preparation Designs for Moderate-sized Class II Composites. J Contemp Dent Pract 2024;25(1):3-9.


Subject(s)
Dental Leakage , Dental Restoration, Permanent , Humans , Dental Restoration, Permanent/methods , X-Ray Microtomography , Dental Cavity Preparation/methods , Dental Leakage/prevention & control , Composite Resins , Molar
17.
Eur Oral Res ; 58(1): 30-36, 2024 Jan 05.
Article in English | MEDLINE | ID: mdl-38481722

ABSTRACT

Purpose: This study aimed to evaluate gap formation between the tooth surface and restorative material in terms of microleakage by using optical coherence tomography (OCT) for self-etch and selective-etch applications of two different universal and one self-etch adhesives. Materials and methods: Sixty non-caries, primary molar teeth were divided into six groups; self-etch and selective-etch application ways of two different universal and one self-etch adhesive systems (n:10). After Class-V cavities were prepared, every tooth was distributed randomly in groups to apply adhesion procedure and then, all cavities were restored with polyacid-modified composite resin. Microleakage was evaluated by measuring the gap between the tooth surface and restoration by a blind researcher with Image J Software from OCT images. During statistical analysis, the significance level was accepted as p<0.05. Results: According to the statistical analysis of the measurements obtained by Image J Software, selective-etch groups showed less gap formation than self-etch groups for each tested adhesive (p<0.05), and self-etch adhesive without etching showed significantly highest gap formation among all groups (p<0.05). Conclusion: Universal adhesives with a selective-etching step might be preferred over self-etch adhesives for long-lasting polyacid-modified composite resin restorations in primary teeth. However, obtained results should be considered with another prospective clinical study for long-term prognosis.

18.
J Dent ; 143: 104905, 2024 04.
Article in English | MEDLINE | ID: mdl-38428716

ABSTRACT

OBJECTIVE: To prepare a bioactive dentin adhesive and investigate its effect on promoting bonding durability of dentin. METHODS: The mineralization of the bioactive glass with high phosphorus (10.8 mol% P2O5-54.2 mol% SiO2-35 mol% CaO, named PSC) and its ability to induce type I collagen mineralization were observed by SEM and TEM. The Control-Bond and the bioactive dentin adhesive containing 20 wt% PSC particles (PSC-Bond) were prepared, and their degree of conversion (DC), microtensile bond strength (µTBS), film thickness and mineralization performance were evaluated. To evaluate the bonding durability, dentin bonding samples were prepared by Control-Bond and PSC-Bond, and mineralizated in simulated body fluid for 24 h, 3 months, and 6 months. Then, the long-term bond strength and microleakage at the adhesive interface of dentin bonding samples were evaluated by microtensile testing and semiquantitative ELIASA respectively. RESULTS: The PSC showed superior mineralization at 24 h and induced type I collagen mineralization to some extent under weakly alkaline conditions. For PSC-Bond, DC was 62.65 ± 1.20%, µTBS was 39.25 ± 4.24 MPa and film thickness was 17.00 ± 2.61 µm. PSC-Bond also formed hydroxyapatite and maintained good mineralization at the bonding interface. At 24 h, no significant differences in µTBS and interface microleakage were observed between the Control-Bond and PSC-Bond groups. After 6 months of aging, the µTBS was significantly higher and the interface microleakage was significantly lower of PSC-Bond group than those of Control-Bond group. SIGNIFICANCE: PSC-Bond maintained bond strength stability and reduced interface microleakage to some extent, possibly reducing the occurrence of secondary caries, while maintaining long-term effectiveness of adhesive restorations.


Subject(s)
Dental Bonding , Dental Cements , Dental Cements/chemistry , Dentin-Bonding Agents/chemistry , Resin Cements/chemistry , Collagen Type I , Silicon Dioxide/pharmacology , Dentin , Tensile Strength , Materials Testing , Composite Resins/chemistry
19.
J Adhes Dent ; 26(1): 53-64, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38329120

ABSTRACT

PURPOSE: This study investigated and compared the bond strengths, microleakage, microgaps, and marginal adaptation of self-adhesive resin composites (SAC) to dentin with or without universal adhesives. MATERIALS AND METHODS: Dentin surfaces of 75 molars were prepared for shear and microtensile bond strength testing (SBS and µTBS). Silicon molds were used to build up direct restorations using the following materials to form 5 groups: 1. Surefil One; 2. Prime&Bond active Universal Adhesive + Surefil One; 3. Vertise Flow; 4. OptiBond Universal + Vertise Flow; 5. Scotchbond Universal + Filtek Z500 (control group). Bonded specimens were thermocycled 10,000x before being tested either for SBS or µTBS using a universal testing machine at a crosshead speed of 0.5 mm/min. Direct mesial and distal class-II cavities were created on 100 sound premolars, with the gingival margin of distal cavities placed below CEJ and restored according to the five groups. After thermocycling, microleakage scores were assessed following immersion of restored premolars in 2% methylene blue dye for 24 h, while marginal gaps and adaptation percentages were investigated on epoxy resin replicas under SEM at magnifications of 2000X and 200X, respectively. Results were statistically analyzed with parametric and non-parametric tests as applicable, with a level of significance set at α = 0.05. RESULTS: Bond strengths, microleakage scores, microgaps, and percent marginal adaptation of Surefil One and Vertise Flow were significantly (p < 0.001) inferior to the control group. Dentin preconditioning with universal adhesives significantly increased the study parameter outcomes of Surefil One and Vertise Flow, yet they were still significantly below the performance of the control group. CONCLUSION: Conventional resin composite outperformed the SAC whether applied solely or in conjunction with their corresponding universal adhesives.


Subject(s)
Dental Bonding , Resin Cements , Bisphenol A-Glycidyl Methacrylate/chemistry , Resin Cements/chemistry , Dentin-Bonding Agents/chemistry , Dental Restoration, Permanent/methods , Dental Cements , Dentin , Composite Resins/chemistry , Materials Testing
20.
Bioengineering (Basel) ; 11(2)2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38391681

ABSTRACT

A screw-fixed superstructure is predominantly selected for implant prostheses because of the concern regarding developing peri-implantitis, although its infection route remains unclear. Focusing on microleakage from access holes, the present study clinically investigated the bacterial flora in access holes with different sealing materials. We examined 38 sites in 19 patients with two adjacent screw-fixed superstructures. Composite resin was used in the control group, and zinc-containing glass ionomer cement was used in the test group. Bacteria were collected from the access holes 28 days after superstructure placement and were subjected to DNA hybridization analysis. The same patient comparisons of the bacterial counts showed a significant decrease in 14 bacterial species for the red, yellow, and purple complexes in the test group (p < 0.05). In addition, the same patient comparisons of the bacterial ratios showed a significant decrease in six bacterial species for the orange, green, yellow, and purple complexes in the test group (p < 0.05). Furthermore, the same patient comparisons of the implant positivity rates showed a significant decrease in the six bacterial species for the orange, yellow, and purple complexes in the test group. The results of this study indicate that zinc-containing glass ionomer cement is effective as a sealing material for access holes.

SELECTION OF CITATIONS
SEARCH DETAIL
...