1.
J Optom ; 11(3): 182-191, 2018.
Article in English | MEDLINE | ID: mdl-28797649

ABSTRACT

PURPOSE: To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. METHODS: Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. RESULTS: No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. CONCLUSION: Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative.


Subject(s)
Cell Count/methods , Diagnostic Techniques, Ophthalmological , Endothelial Cells/cytology , Endothelium, Corneal/cytology , Glaucoma/diagnosis , Microscopy/methods , Adult , Aged , Analysis of Variance , Case-Control Studies , Diagnosis, Computer-Assisted , Female , Humans , Male , Middle Aged , Reproducibility of Results
2.
J Optom ; 11(3): 192-197, 2018.
Article in English | MEDLINE | ID: mdl-28254359

ABSTRACT

PURPOSE: To compare and analyze the interchangeability of three measuring systems, each based on a different technique, for central corneal thickness (CCT) analysis. METHODS: CCT measurements were measured using optical coherence tomography (OCT), non-contact specular microscopy (NCSM), and ultrasonic pachymetry (USP) in 60 eyes of 60 healthy patients with a mean age of 66.5±15.0 years and a mean spherical equivalent of 0.43±1.14 D. Analysis of variations in measurement concordance and correlation among the three different methods were performed. Comparison of CCT measurements were done using Bland-Altman plots (with bias and 95% confidence intervals), intraclass correlation coefficient (ICC), and paired t-student analysis. RESULTS: Mean CCT values were: 549.20±26.91µm for USP (range 503-618µm), 514.20±27.49µm for NCSM (range 456-586µm) and 542.80±25.56µm for OCT (range 486-605µm). CCT values obtained with NCMS were significantly lower than those obtained with OCT and USP methods. NCMS CCT value was 36.08±10.72µm lower than USP value (p<0.05), and NCMS CCT value was 7.88±8.86µm lower than OCT value (p<0.05). ICC between USP-NCSM pair was 0.488 and 0.909 between USP-OCT pair. CONCLUSION: OCT and UPS offered highly comparable results, whereas NCSM offered lower mean CCT values compared to the other two methods. Therefore, NCSM should not be considered a reliable method for measuring CCT and should rather be considered for assessing longitudinal changes in the same patient.


Subject(s)
Corneal Pachymetry/methods , Diagnostic Techniques, Ophthalmological , Microscopy/methods , Tomography, Optical Coherence/methods , Adult , Aged , Aged, 80 and over , Corneal Pachymetry/instrumentation , Female , Humans , Middle Aged , Prospective Studies , Reproducibility of Results
3.
Ciênc. rural (Online) ; 47(12): e20170027, Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-1044917

ABSTRACT

ABSTRACT: The goal of this study was to describe the normal values of corneal endothelial cell density and hexagonality in healthy rabbits' eyes using contact specular microscopy. Both eyes of 18 rabbits, males and females, of different ages were evaluated. The eyes were divided into three groups of 12 each according to the age range of the animals: G1 (6 months old), G2 (12 months old), and G3 (48 months old). Parameters studied included mean endothelial cell density and hexagonality. For Group I, the mean cell density was 2307 cells per mm2. For GII, the mean cell density was 1895 cells per mm2. For G III, the mean cell density was 1818 cells per mm2. Cell density decreased significantly with aging (P<0.001) among the three groups. Pleomorphism in the rabbits of GI was 74.33±10.08. In the rabbits of GII it was 71.83±11.38. In the rabbits of GIII it was 64.02±28.80. Significant differences (P<0.001) were evident between GI and GIII and GII and GIII but not between Groups I and II. The results showed a decrease in number of cells and hexagonality with aging. Corneal endothelium of rabbits suffers changes due to advancing age both in terms of cell density and morphology.


RESUMO: Objetivou-se avaliar a densidade celular e a hexagonalidade do endotélio da córnea de coelhos saudáveis usando um microscópio especular de contato. Os dois olhos de 18 coelhos, machos ou fêmeas, de diferentes idades foram avaliados. Os olhos foram separados em três grupos de 12 olhos cada em função da idade: G1 (6 meses de idade), G2 (12 meses de idade) e G3 (48 meses de idade). Os parâmetros estudados incluíram a densidade celular e a hexagonalidade. Para o Grupo I, a densidade celular média foi de 2307 células por mm2. Para GII, a densidade celular média foi de 1895 células por mm2. Para G III, a densidade celular média foi de 1818 células por mm2. A densidade celular diminuiu significativamente com o envelhecimento (P<0,001) entre os três grupos. O pleomorfismo nos coelhos de GI foi de 74,33±10,08. Nos coelhos do GII foi 71,83±11,38. Nos coelhos de GIII foi de 64,02±28,80. Diferenças significativas (P<0,001) foram evidentes entre GI e GIII e GII e GIII, mas não entre os Grupos I e II. Os resultados revelaram diminuição da densidade celular e da hexagonalidade com o avanço da idade. O endotélio da córnea de coelhos sofre alterações devido ao avanço da idade tanto na densidade celular e quanto na morfologia.