Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 244
Filter
1.
Int J Surg Case Rep ; 123: 110186, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39181033

ABSTRACT

INTRODUCTION: Biportal endoscopy, a newly developed technique rapidly applied in lumbar spine surgery, has recently been utilized for treating cervical spine diseases. We present a case of cervical spondylotic myelopathy managed with open-door laminoplasty fixed by mini-plate and performed with biportal endoscopy assistance. PRESENTATION OF CASE: The patient, a 62-year-old woman, presented with gradually developing weakness in the lower extremities. CT and MR images showed cervical stenosis at C4-5 and C5-6. We performed a posterior open-door laminoplasty using biportal endoscopy assisted by a mini-plate. After completing the gutters on both sides of the hinge and open-door, we detached the spinous process from the lamina through endoscopic-guided burr grinding. The skin incisions of the portals on the open-door side were connected for direct fixation of the elevated lamina with a mini-plate. There was improvement in ambulatory capacity for the patient along with radiological evidence of decompressed cervical canal. DISCUSSION: Endoscopic technology is increasingly employed in spinal surgery, with several studies documenting the utilization of biportal endoscopic techniques to facilitate open-door laminoplasty procedures for managing myelopathic cervical spondylosis. The procedures we report allow for safer and more efficient placement of the mini-plate that prevents door re-closing. CONCLUSIONS: The potential applications of biportal endoscopic technology in open-door cervical spine surgery are worth considering, given the soft tissue damage caused by traditional posterior cervical spine surgery. However, the safety and effectiveness of this method still require more studies with a larger number of cases and longer follow-up to be substantiated.

2.
Gen Dent ; 72(5): 60-65, 2024.
Article in English | MEDLINE | ID: mdl-39151084

ABSTRACT

Distalization of mandibular molars comes with significant challenges, especially in adult and young adult patients. In selected cases, third molar extraction procedures offer the opportunity to place miniplates for anchorage to distalize mandibular molars, providing additional solutions to the traditional extraction of premolars or a single incisor. This approach can be of special interest to adult patients, who may have life commitments and time restraints that limit traditional orthodontic and surgical treatment options, and it can improve the efficiency of dental care. This case series describes 3 clinical scenarios in which miniplates were placed with minimal invasiveness during the removal of impacted third molars, offering the patients nontraditional orthodontic treatment options. Awareness of these options is essential for general dentists so that they can explain all treatment possibilities and provide appropriate referrals to patients with impacted third molars.


Subject(s)
Orthodontic Anchorage Procedures , Tooth, Impacted , Humans , Female , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Tooth, Impacted/surgery , Tooth, Impacted/therapy , Tooth Extraction , Tooth Movement Techniques/methods , Tooth Movement Techniques/instrumentation , Referral and Consultation , Molar, Third/surgery , Bone Plates , Male , Adult , General Practice, Dental , Young Adult , Mandible/surgery
3.
Am J Transl Res ; 16(7): 3129-3138, 2024.
Article in English | MEDLINE | ID: mdl-39114674

ABSTRACT

OBJECTIVE: To compare the outcome of mini-plate versus Kirschner wire (K-wire) internal fixation for treating fifth metacarpal basal fractures with carpometacarpal joint dislocation. METHOD: A total of 46 patients with fifth metacarpal basal fractures combined with carpometacarpal joint dislocation were divided into two groups. The control group received K-wire fixation, while the observation group underwent mini-plate fixation. We assessed treatment effectiveness, surgical parameters, range of motion, serum stress markers, quality of life scores, and postoperative complication rates. A multivariable logistic regression analysis was performed to identify factors influencing postoperative joint function. RESULTS: The observation group demonstrated a significantly higher excellent and good rate compared to the control group (P<0.05). Additionally, the observation group had a lower intraoperative bleeding volume, shorter incision lengths, and faster fracture healing times, all significant differences (all P<0.05). Postoperative assessments indicated that range of motion, quality of life scores, and superoxide dismutase levels were significantly improved in the observation group (P<0.05). Conversely, cortisol, angiotensin II, and norepinephrine levels, along with the incidence of postoperative complications, were lower in the observation group compared to the control group (all P<0.05). Logistic regression analysis identified the surgical method as an independent factor affecting postoperative metacarpal joint function (OR = 0.16, P = 0.003). CONCLUSION: Mini-plate internal fixation is superior to K-wire fixation for the treatment of fifth metacarpal basal fractures with carpometacarpal joint dislocation. It promotes faster fracture healing, reduces serum stress markers, enhances joint mobility and quality of life, and decreases postoperative complications.

4.
BMC Musculoskelet Disord ; 25(1): 522, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38970051

ABSTRACT

BACKGROUND: For the treatment of coronoid process fractures, medial, lateral, anterior, anteromedial, and posterior approaches have been increasingly reported; however, there is no general consensus on the method of fixation of coronal fractures. Here, we present a highly-extensile minimally invasive approach to treat coronoid process fractures using a mini-plate that can achieve anatomic reduction, stable fixation, and anterior capsular repair. Further, the study aimed to determine the complication rate of the anterior minimally invasive approach and to evaluate functional and clinical patient-reported outcomes during follow-up. METHODS: Thirty-one patients diagnosed with coronoid fractures accompanied with a "terrible triad" or posteromedial rotational instability between April 2012 and October 2018 were included in the analysis. Anatomical reduction and mini-plate fixation of coronoid fractures were performed using an anterior minimally invasive approach. Patient-reported outcomes were evaluated using the Mayo Elbow Performance Index (MEPI) score, range of motion (ROM), and the visual analog score (VAS). The time of fracture healing and complications were recorded. RESULTS: The mean follow-up time was 26.7 months (range, 14-60 months). The average time to radiological union was 3.6 ± 1.3 months. During the follow-up period, the average elbow extension was 6.8 ± 2.9° while the average flexion was 129.6 ± 4.6°. According to Morrey's criteria, 26 (81%) elbows achieved a normal desired ROM. At the last follow-up, the mean MEPI score was 98 ± 3.3 points. There were no instances of elbow instability, elbow joint stiffness, subluxation or dislocation, infection, blood vessel complications, or nerve palsy. Overall, 10 elbows (31%) experienced heterotopic ossification. CONCLUSION: An anterior minimally invasive approach allows satisfactory fixation of coronoid fractures while reducing incision complications due to over-dissection of soft tissue injuries. In addition, this incision does not compromise the soft tissue stability of the elbow joint and allows the patient a more rapid return to rehabilitation exercises.


Subject(s)
Bone Plates , Elbow Joint , Fracture Fixation, Internal , Fractures, Comminuted , Range of Motion, Articular , Ulna Fractures , Humans , Male , Female , Ulna Fractures/surgery , Ulna Fractures/diagnostic imaging , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Middle Aged , Adult , Fractures, Comminuted/surgery , Fractures, Comminuted/diagnostic imaging , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Elbow Joint/physiopathology , Treatment Outcome , Retrospective Studies , Follow-Up Studies , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/instrumentation , Fracture Healing , Aged , Patient Reported Outcome Measures , Young Adult
5.
BMC Musculoskelet Disord ; 25(1): 515, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38961403

ABSTRACT

OBJECTIVE: The purpose of this study is to compare radiological and clinical outcomes between alternate levels (C4 and C6) and all levels mini-plate fixation in C3-6 unilateral open-door laminoplasty. METHODS: Ninety-six patients who underwent C3-6 unilateral open-door laminoplasty with alternate levels mini-plate fixation (54 patients in group A) or all levels mini-plate fixation (42 patients in group B) between September 2014 and September 2019 were reviewed in this study. Radiologic and clinical outcomes were assessed. Clinical results included Visual Analogue Scale (VAS) of axial neck pain and Japanese Orthopedic Association (JOA) score. Radiographic results included cervical range of motion (ROM), cervical curvature index (CCI), and the spinal canal expansive parameters including open angle, anteroposterior diameter (APD), and Pavlov`s ratio. RESULTS: There was no significant difference in VAS, JOA score, ROM, and CCI between two groups. There was no significant difference in canal expansion postoperatively between two groups. However, open angle, APD, and Pavlov`s ratio in group A decreased significantly during the follow-up. In group B, APD, Pavlov`s ratio, and open angle were maintained until the final follow-up. There was no hardware failure or lamina reclosure occurred in both groups during the follow-up. The mean cost of group B was higher than that of group A. CONCLUSIONS: Despite the differences in the maintenance of canal expansion, alternate levels mini-plate fixation can achieve similar clinical outcomes as all levels mini-plate fixation in C3-6 unilateral open-door laminoplasty. As evidenced in this study, we believe C3-6 laminoplasty with alternate levels (C4 and C6) mini-plate fixation is an economical, effective, and safe treatment method.


Subject(s)
Bone Plates , Cervical Vertebrae , Laminoplasty , Humans , Cervical Vertebrae/surgery , Cervical Vertebrae/diagnostic imaging , Laminoplasty/methods , Female , Middle Aged , Retrospective Studies , Male , Aged , Treatment Outcome , Range of Motion, Articular , Adult , Neck Pain/etiology , Neck Pain/surgery
6.
J Clin Med ; 13(11)2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38893045

ABSTRACT

Background/Objectives: The use of miniplates for stabilizing bones post orthognathic surgery has surged in popularity due to their efficacy in ensuring stability and hastening recovery. However, controversy exists regarding what should be done with these miniplates after surgery. Some surgeons advocate for their removal, while others suggest leaving them in place. This study sought to assess the frequency, causes, and potential risk factors linked with miniplate removal in orthognathic procedures. Methods: A thorough meta-analysis was conducted by scrutinizing studies from various databases including PubMed, Google Scholar, Embase, and Scopus, focusing on publications spanning from 1989 to 2023. Results: Ten studies meeting the inclusion criteria, encompassing 1603 patients, were chosen for inclusion in the meta-analysis. The male-to-female ratio varied from 0.7:1 to 4:1. Overall, 5595 miniplates were inserted, with 294 (5.3%) being subsequently removed. Primary reasons for miniplate removal included infection (161 cases, 2.9%), exposure of miniplates (34 cases, 0.6%), and palpable plates (23 cases, 0.4%). Other indications comprised pain, patient preference, and temperature sensitivity. Less frequent causes for miniplate removal included sinusitis, secondary surgery, and dental pathology. The mean duration of miniplate removal was 5.5 months, with the majority (56.1%) being removed from the mandible rather than the maxilla. In conclusion, this meta-analysis underscores the importance of miniplate removal when hardware causes complications and physical discomfort. The primary reasons for removing miniplates were infection and plate exposure, with the mandible being the most common removal site. Conclusions: These findings emphasize the need for continued monitoring to assess the fate of miniplates in orthognathic surgery and provide valuable information for future clinical decision-making.

7.
Med Eng Phys ; 129: 104176, 2024 07.
Article in English | MEDLINE | ID: mdl-38906569

ABSTRACT

OBJECTIVE: To evaluate and compare the biomechanical behavior of three-dimensionally (3D) printed patient-specific Ti6Al4V with commercially made titanium mini plates following Lefort-I osteotomy using finite element analysis. METHODS: Le Fort I osteotomy was virtually simulated with a 5 mm maxillary advancement and mediolateral rotation in the coronal plane, resulting in a 3 mm gap on the left side's posterior. Two fixation methods were modeled using software to compare 3D-printed Ti6Al4V and commercial titanium mini plates, both featuring a 4-hole l-shape with thicknesses of 0.5 mm and 0.7 mm at the strategic piriform rim and zygomaticomaxillary buttress locations. Using ANSYS R19.2, finite element models were developed to assess the fixation plates and maxilla's stress, strain, and displacement responses under occlusal forces of 125, 250, and 500 N/mm². RESULTS: This comparative analysis revealed slight variation in stress, strain, and displacement between the two models under varying loading conditions. Stress analysis indicated maximum stress concentrations at the vertical change in the left posterior area between maxillary segments, with the Ti6Al4V model exhibiting slightly higher stress values (187 MPa, 375 MPa, and 750 MPa) compared to the commercial titanium model (175 MPa, 351 MPa, and 702 MPa). Strain analysis showed that the commercial titanium model recorded higher strain values at the bending area of the l-shaped miniplate. Moreover, displacement analysis revealed a maximum of 3 mm in the left posterior maxilla, with the Ti6Al4V model demonstrating slightly lower displacement values under equivalent forces. CONCLUSION: The maximum stress, strain, and segment displacement of both fixation models were predominantly concentrated in the area of the gap between the maxillary segments. Notably, both fixation models exhibited remarkably close values, which can be attributed to the similar design of the fixation plates.


Subject(s)
Alloys , Bone Plates , Finite Element Analysis , Osteotomy, Le Fort , Printing, Three-Dimensional , Stress, Mechanical , Titanium , Biomechanical Phenomena , Humans , Osteotomy, Le Fort/instrumentation , Mechanical Phenomena , Maxilla/surgery , Materials Testing
8.
J Maxillofac Oral Surg ; 23(3): 524-530, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38911404

ABSTRACT

Introduction: To compare the biomechanical parameters of microplates and the combined miniplate-microplate for fixing zygomaticomaxillary complex (ZMC) fractures using nonlinear finite element analysis (FEA). Material and Methods: Two samples of ZMC fracture models were prepared. In sample 1 (S1), the fractures were stabilized with microplates, and in sample 2 (S2), with miniplates plus microplates. FEA software was used to measure the displacement, Von Mises stress distribution (VMSD), and maximum principal stress distribution (MPSD). Results: The displacement was 6.7 µm in the L-shaped plate of both samples, 4.4 µm in the S1 lateral-edge plate, 4.8 µm in the S2 lateral-edge plate, 5.8 µm in the S1 bottom-edge plate, and 5.6 µm in the S2 bottom-edge plate. The VMSD was 41.1 MPa in the S1 lateral-edge plate, 24.3 MPa in the S2 lateral-edge plate, 7.6 MPa in the S1 Lshaped plate, 9.6 MPa in S2 L-shaped plate, 28.5 MPa in the S1 bottom-edge plate, and 11.8 MPa in the S2 bottom-edge plate. The MPSD was 46.2 MPa in the S1 lateral-edge plate, 26.4 MPa in the S2 lateral-edge plate, 3.6 MPa in S1 L-shaped plate, 4.2 MPa in S2 L-shaped plate, 30.9 MPa in S1 bottom-edge plate, and 14.1 MPa in the S2 bottom-edge plate. Conclusion: The L-shaped and lateral-edge plates in both samples had the highest and lowest amount of displacement, respectively. The lateral-edge plates in both samples had the highest VMSD and MPSD, which was higher in S1 than S2. The L-shaped plate had the lowest VMSD and MPSD in both samples.

9.
J Orofac Orthop ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748283

ABSTRACT

OBJECTIVES: This study aimed to analyze the global scholarly production of articles related to temporary anchorage devices (TADs) from 1998-2023 in peer-reviewed dental journals indexed in the Web of Science. MATERIALS AND METHODS: A database of TADs-related articles was created via a Web of Sciences structured search. The bibliometric characteristics of the studies, including the number of citations, publication year, journal title, journal impact factor (IF), authorship, contributing institutions and countries, thematic field, and study design, were extracted. Keyword co-occurrence network analyses and the correlation between the number of citations and the article age, journal IF, and journal quartile of each article were performed. RESULTS: The top 50 cited articles were published from 1999-2016, and the total number of citations ranged from 82-602, with 160.36 citations/paper on average. Most of the articles originated from Japan (n = 12), with the most remarkable contributions from Nihon and Okayama Universities, Japan (n = 5, each). The American Journal of Orthodontics and Dentofacial Orthopedics had the most cited articles, with 196.57 citations/paper on average. A significant positive correlation occurred between the number of citations and publication age (rho = 0.392, P = 0.005). CONCLUSION: Our scientometric analysis reported the characteristics of TADs-related articles published over 25 years. Most highly-cited articles were published between 2005 and 2008. The positive correlation between articles' publication date and the number of citations might impact the top 50 within the next 5-10 years.

10.
Br J Oral Maxillofac Surg ; 62(5): 441-447, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38637215

ABSTRACT

The parasymphysis area of the mandible is highly dynamic because it is subjected to both occlusal and muscular forces. As a result, the fractures in this transition zone have a special pattern, posing a challenge for surgeons whether to use one miniplate versus two miniplates, as per Champy's recommendations. The commonest complication resulting to treat this area is mental nerve paraesthesia due to the dissection and stretching of the nerve. Hence, an in vitro research study of a newly designed 'Zeta' miniplate is performed, to evaluate the biomechanical behaviour using finite element (FE) analysis and biomechanical analysis along with a comparison study with the conventional miniplate configurations. The results showed that the Zeta miniplate produces the lowest stresses 17.511 MPa and the least total structural deformation of 0.0011 mm after applying the maximum occlusal bite force. On application of torsional load, total structural deformation was 0.0004 mm and von Mises (VM) stress value was 0.24 MPa which was lowest when compared with the two miniplate system. Hence, the newly developed Zeta miniplate is superior in terms of stability. Another benefit of its design is that it helps in preventing mental nerve paraesthesia and tooth root damage while fixing and stabilising the fractured bony segments.


Subject(s)
Bite Force , Bone Plates , Finite Element Analysis , Fracture Fixation, Internal , Mandible , Mandibular Fractures , Stress, Mechanical , Mandibular Fractures/surgery , Humans , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Mandible/surgery , Torsion, Mechanical , Equipment Design , Materials Testing , Paresthesia/etiology , Mandibular Nerve , Titanium/chemistry , Miniaturization
11.
Br J Oral Maxillofac Surg ; 62(4): 349-360, 2024 May.
Article in English | MEDLINE | ID: mdl-38604919

ABSTRACT

This review examines the prevailing modalities for fractures of the anterior mandible, which represent a significant proportion of the maxillofacial injuries commonly treated by oral and maxillofacial surgeons. The article traces the historical shift from conservative techniques to the dominant management strategies of open reduction and fixation. Encompassing a range of studies, the review, in accordance with PRISMA 2020 recommendations, meticulously examines various fixation methods, assessing their efficacy in achieving stability of fracture, early healing, and mobilisation. The comparison of these methods highlights their unique advantages and limitations, and demonstrates the need for more nuanced and precise approaches. The review emphasises evidence-based methodology in the management of anterior mandibular fractures (AMF), highlighting the benefits offered by innovative techniques such as 3D miniplates. It also acknowledges the advantages provided by older fixation devices such as lag screws. The importance of postoperative outcomes and the need for tailored treatment strategies are recognised, considering the complex nature of these fractures.


Subject(s)
Fracture Fixation, Internal , Mandibular Fractures , Humans , Bone Plates , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Mandibular Fractures/surgery , Mandibular Fractures/therapy
12.
Korean J Orthod ; 54(2): 108-116, 2024 03 25.
Article in English | MEDLINE | ID: mdl-38533598

ABSTRACT

Objective: : A three-dimensional-printed individual titanium plate was applied for maxillary protraction to eliminate side effects and obtain the maximum skeletal effect. This study aimed to explore the stress distribution characteristics of sutures during maxillary protraction using individual titanium plates in various directions and locations. Methods: : A protraction force of 500 g per side was applied at forward and downward angles between 0° and 60° with respect to the Frankfort horizontal plane, after which the titanium plate was moved 2 and 4 mm upward and downward, respectively. Changes in sutures with multiple protraction directions and various miniplate heights were quantified to analyze their impact on the maxillofacial bone. Results: : Protraction angle of 0-30° with respect to the Frankfort horizontal plane exhibited a tendency for counterclockwise rotation in the maxilla. At a 40° protraction angle, translational motion was observed in the maxilla, whereas protraction angles of 50-60° tended to induce clockwise rotation in the maxilla. Enhanced protraction efficiency at the lower edge of the pyriform aperture was associated with increased height of individual titanium plates. Conclusions: : Various protraction directions are suitable for patients with different types of vertical bone surfaces. Furthermore, when the titanium plate was positioned lower, the protraction force exhibited an increase.

13.
J Clin Med ; 13(6)2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38541832

ABSTRACT

Background: Wagstaffe fracture constitutes an indirect injury to the AITFL and can precipitate syndesmotic instability. The prevailing fixation methods often involve the use of mini-screws or K-wires, with absorbable suture repair reserved for cases with small or comminuted fragments exhibiting instability. In this study, we devised a mini-plate fixation method capable of securing the fracture fragment irrespective of its size or condition. Methods: A retrospective chart review was conducted on patients who underwent surgery for ankle fractures between May 2022 and October 2023. The surgical technique involved direct fixation of the Wagstaffe fracture using mini-plate fixation. Radiologic evaluation was performed using postoperative CT images, and clinical outcomes were assessed using the OMAS and VAS. Results: Fourteen patients with an average age of 62.5 years were included. Most fractures were associated with the supination-external rotation type. The average preoperative OMAS significantly improved from 5.95 to 83.57 postoperatively. The average VAS score decreased from 7.95 preoperatively to 0.19 postoperatively. Conclusions: The mini-plate technique for Wagstaffe fractures exhibited dependable fixation strength, effective fracture reduction, a minimal complication rate, and judicious surgical procedure duration.

14.
J Orthod Sci ; 13: 3, 2024.
Article in English | MEDLINE | ID: mdl-38516116

ABSTRACT

OBJECTIVE: Measuring the condylar volume changes after treatment with skeletally anchored type IV Herbst appliance vs. Twin Force Bite Corrector (TFBC) in class II malocclusion in young adult patients. MATERIALS AND METHODS: Twenty class II malocclusion participants were randomly involved in our randomized clinical study. They are divided equally into two groups: group I (10 patients with an age range of 16 to 18 years and a mean age of (17.15 ± 0.62) (five males and five females) with a mean Angle formed between (A) point and (Nasion) point and (B) point, to determine anteroposterior relation between maxilla and mandible (ANB) of 6.20 (1.03) and a mean mandibular length of 106.1 (1.7), who were treated by a skeletally anchored type IV Herbst appliance, supported at the mandible by two mini-plates fixed bilaterally at the mandibular symphysis; group II (10 patients with an age range of 15 to 18 years and a mean age of (16.85 ± 0.33) (six males and four females) with a mean ANB of 6.80 (0.89) and a mean mandibular length of 107.3 (2.36), who were treated by a TFBC that was installed just mesial to the tube of the maxillary first permanent molar and distal to the bracket of the lower canine for 4 months. According to the Index of Orthognathic Functional Treatment Need (IOFTN) index, the participants in both groups have grade 4 (great need for treatment) as they have excessive overjet (6-9 mm). Cone-beam computed tomography (CBCT) was taken just before installing fixed functional appliances and after the removal. The condylar volume was measured using Dolphin software. Parametric measurements were performed by the independent t-test, while non-parametric variables (percent change) were compared by the Mann-Whitney U-test. RESULTS: On the right side, the Herbst group recorded a percent increase (median = 1.23%), while TFBC recorded a median percent decrease (-7.85%). This change is statistically significant (P = 0.008). CONCLUSIONS: The difference in the condylar volume was significantly higher with the mini-plate anchored Herbst appliance than with the dentally anchored TFBC group.

15.
J Maxillofac Oral Surg ; 23(1): 107-113, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38312972

ABSTRACT

The aim of this study was to compare the stability and clinical outcomes between the two miniplates and sagittal split plate (SSOP) in angle fracture fixation. Thirty-eight patients with a mandibular angle fracture were selected and divided randomly into two groups. Intervention was treated with SSOP, and the control group was treated with conventional two miniplates. Clinical evaluation included occlusion, edema, nerve affection, wound dehiscence and mouth opening. Radiographic parameters included the measurement of inter-ramus distance, inter-mental distance and bone density. All clinical parameters were evaluated at one week, one month and three months intervals. Radiographic parameters were evaluated immediately postoperative, and after three months. Results showed that SSOP had less postoperative complications (10.50%) than the two miniplates (31.60%). It can be concluded that both methods offered high performance in management of mandibular angle fractures. However, SSOP group had a significantly shorter operating time, increased bone density and less edema. Clinical trial registration number: NCT03839368.

16.
J Maxillofac Oral Surg ; 23(1): 114-121, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38312983

ABSTRACT

Purpose: To evaluate and compare the efficacy of three osteosynthesis systems in fixation of mandibular angle fractures using Finite Element Analysis. Materials and Methods: In this study, we used a three-dimensional finite element analysis to assess the stress, deformation and strain in three different groups with bite force loads. A three-dimensional finite element model of the mandible with three different plating techniques using modelling software 'Solidworks2018' and was analysed for stress, deformation and strain produced in the bone following biting loads of different magnitude using analysing software 'ANSYS Workbench'. Results: In this study, we found out that the tensile forces in the matrix miniplate with vertical struts were well distributed in the cortical and cancellous bone on comparison with other two fixation systems in fixation of the mandibular angle fracture and therefore prevents lateral displacement, torsion and bending. The matrix miniplate system revealed less displacement of the fracture segments as compared to the other two plating systems. Conclusion: The use of matrix miniplate for the treatment of mandibular angle fractures can be considered efficacious. The stress transferred onto the cortical & cancellous bone is least in the matrix plate leading to better stability of the fixation system.

17.
Front Bioeng Biotechnol ; 12: 1353797, 2024.
Article in English | MEDLINE | ID: mdl-38375455

ABSTRACT

Objective: Compare the spine's stability after laminectomy (LN) and laminoplasty (LP) for two posterior surgeries. Simultaneously, design a new vertebral titanium porous mini plate (TPMP) to achieve firm fixation of the open-door vertebral LP fully. The objective is to enhance the fixation stability, effectively prevent the possibility of "re-closure," and may facilitate bone healing. Methods: TPMP was designed by incorporating a fusion body and porous structures, and a three-dimensional finite element cervical model of C2-T1 was constructed and validated. Load LN and LP finite element models, respectively, and analyze and simulate the detailed processes of the two surgeries. It was simultaneously implanting the TPMP into LP to evaluate its biomechanical properties. Results: We find that the range of motion (ROM) of C4-C5 after LN surgery was greater than that of LP implanted with different plates alone. Furthermore, flexion-extension, lateral bending, and axial rotation reflect this change. More noteworthy is that LN has a much larger ROM on C2-C3 in axial rotation. The ROM of LP implanted with two different plates is similar. There is almost no difference in facet joint stress in lateral bending. The facet joint stress of LN is smaller on C2-C3 and C4-C5, and larger more prominent on C5-C6 in the flexion-extension. Regarding intervertebral disc pressure (IDP), there is little difference between different surgeries except for the LN on C2-C3 in axial rotation. The plate displacement specificity does not significantly differ from LP with vertebral titanium mini-plate (TMP) and LP with TPMP after surgery. The stress of LP with TPMP is larger in C4-C5, C5-C6. Moreover, LP with TMP shows greater stress in the C3-C4 during flexion-extension and lateral bending. Conclusion: LP may have better postoperative stability when posterior approach surgery is used to treat CSM; at the same time, the new type of vertebral titanium mini-plate can achieve almost the same effect as the traditional titanium mini-plate after surgery for LP. In addition, it has specific potential due to the porous structure promoting bone fusion.

18.
Cureus ; 16(1): e53031, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38410334

ABSTRACT

This case report documents the diagnosis and successful management of a substantial periapical lesion located in the lower left region of the jaw. The patient presented with clinical symptoms indicative of periapical pathology, and radiographic examination revealed an extensive radiolucent lesion. The chosen treatment approach involved endodontic intervention coupled with surgical decompression, leading to the resolution of the lesion and restoration of oral health. This case underscores the significance of an accurate diagnosis and a multidisciplinary treatment approach in addressing large periapical lesions.

19.
Orthod Craniofac Res ; 27(1): 102-109, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37496461

ABSTRACT

OBJECTIVE: This finite element analysis (FEA) aimed to assess the stress distribution in the mandible and fixation system with various directions of the intermaxillary fixation (IMF) using mini-implants (MIs) and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy (BSSRO). MATERIALS AND METHODS: A total of nine mandibular advancement models were set according to the position of the MIs (1.6 mm in diameter, 8 mm in length) and direction of the IMF elastics (1/4 inch, 5 oz). Major and minor principal stresses in the cortical and cancellous bones, von Mises stresses in the fixation system (miniplate and monocortical screws), and bending angles of the miniplate were analysed. RESULTS: Compressive and tensile stress distributions in the mandible and von Mises stress distributions in the fixation system were greater in models with a Class III IMF elastic direction and a higher IMF elastic force than in models with a Class II IMF elastic direction and a lower IMF elastic force. The bending angle of the miniplate was negligible. CONCLUSIONS: Stress distributions in the bone and fixation system varied depending on the direction, amount of force, and position of IMF elastics and MIs. Conclusively, IMF elastics in the Class II direction with minimal load in the area close to the osteotomy site should be recommended.


Subject(s)
Dental Implants , Mandibular Advancement , Orthodontic Anchorage Procedures , Osteotomy, Sagittal Split Ramus , Finite Element Analysis , Bone Plates , Bone Screws , Stress, Mechanical , Mandible/surgery
20.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1021929

ABSTRACT

BACKGROUND:Fractures of the fifth metacarpal shaft are common in the clinic,and surgical treatment is mostly performed with open reduction plate fixation,but postoperatively,most patients require removal of the internal fixation and require secondary hospitalization.Transcutaneous fixation with a Kirschner wire has many advantages,such as less trauma,small incision,and no need for reoperation. OBJECTIVE:To comparatively analyze the clinical efficacy of percutaneous fixation of a Kirschner wire with miniplate placement in the transverse plane for treatment of the fifth metacarpal shaft fracture. METHODS:A total of 60 patients who underwent surgery for the fifth metacarpal shaft fracture at Binzhou Medical University Hospital between May 2018 and May 2020 were retrospectively analyzed and divided into two groups according to the operation method.30 patients in the plate group were treated with open reduction miniplate internal fixation;30 patients in the Kirschner wire group were treated with closed reduction and percutaneous fixation with a Kirschner wire(of which 5 patients were treated with mini-incision incision assisted fixation).The length of hospital stay,operation time,incision healing grade,incision length,intraoperative blood loss,intraoperative fluoroscopy number,and postoperative complications were compared between the two groups.The fracture healing time,grip strength,and the motion range of the fifth metacarpophalangeal joint were recorded in the two groups,and the functional outcomes of the fingers were evaluated by the total active movement method. RESULTS AND CONCLUSION:(1)Patients in both groups were followed up for 13-18 months.The differences in hospital stay,operation time,and incision healing grade between the two groups were not statistically significant(P>0.05).(2)The amount of intraoperative blood loss and incision length in the Kirschner wire group were less than those in the plate group(P<0.05).The number of intraoperative fluoroscopies in the plate group was less than that in the Kirschner wire group(P<0.05).There was no significant difference in the fracture healing time between the two groups(P>0.05).(3)At the last follow-up,the efficacy was evaluated according to the total active movement method.The excellent and good rate was 87%in the Kirschner wire group and 90%in the plate group,with no significant difference.There were no significant differences between the two groups in the motion range and grip strength of the fifth metacarpophalangeal joint at the last follow-up(P>0.05).(4)Pin tract infection occurred in one case after Kirschner wire placement,which improved after giving iodophor to enhance the dressing change.There was 1 case of pin tail irritating skin symptoms,which resolved after the removal of the Kirschner wires.There were 12 patients in the plate group who were hospitalized after 12 months for personal reasons for plate removal,and all in the Kirschner wire group were removed on an outpatient basis.In the plate group,three patients developed sensory numbness of the skin on the dorsal side of the distal fifth metacarpal and the dorsal side of the little finger,which resolved gradually with oral administration of mecobalamin after surgery.There were no instances of nonunion and refracture with internal fixation in either group.(5)Our results showed that both of these surgical procedures achieved good results in the treatment of fifth metacarpal shaft fracture with excellent functional recovery of the fingers,but the transverse fixation with percutaneous Kirschner wire has many advantages,such as less trauma,small incision,low cost,and convenient removal of internal fixation.

SELECTION OF CITATIONS