Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 11.015
Filter
1.
Dev Sci ; : e13538, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949566

ABSTRACT

Impaired numerosity perception in developmental dyscalculia (low "number acuity") has been interpreted as evidence of reduced representational precision in the neurocognitive system supporting non-symbolic number sense. However, recent studies suggest that poor numerosity judgments might stem from stronger interference from non-numerical visual information, in line with alternative accounts that highlight impairments in executive functions and visuospatial abilities in the etiology of dyscalculia. To resolve this debate, we used a psychophysical method designed to disentangle the contribution of numerical and non-numerical features to explicit numerosity judgments in a dot comparison task and we assessed the relative saliency of numerosity in a spontaneous categorization task. Children with dyscalculia were compared to control children with average mathematical skills matched for age, IQ, and visuospatial memory. In the comparison task, the lower accuracy of dyscalculics compared to controls was linked to weaker encoding of numerosity, but not to the strength of non-numerical biases. Similarly, in the spontaneous categorization task, children with dyscalculia showed a weaker number-based categorization compared to the control group, with no evidence of a stronger influence of non-numerical information on category choice. Simulations with a neurocomputational model of numerosity perception showed that the reduction of representational resources affected the progressive refinement of number acuity, with little effect on non-numerical bias in numerosity judgments. Together, these results suggest that impaired numerosity perception in dyscalculia cannot be explained by increased interference from non-numerical visual cues, thereby supporting the hypothesis of a core number sense deficit. RESEARCH HIGHLIGHTS: A strongly debated issue is whether impaired numerosity perception in dyscalculia stems from a deficit in number sense or from poor executive and visuospatial functions. Dyscalculic children show reduced precision in visual numerosity judgments and weaker number-based spontaneous categorization, but no increasing reliance on continuous visual properties. Simulations with deep neural networks demonstrate that reduced neural/computational resources affect the developmental trajectory of number acuity and account for impaired numerosity judgments. Our findings show that weaker number acuity in developmental dyscalculia is not necessarily related to increased interference from non-numerical visual cues.

2.
Med Biol Eng Comput ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963467

ABSTRACT

Continuous blood pressure (BP) provides essential information for monitoring one's health condition. However, BP is currently monitored using uncomfortable cuff-based devices, which does not support continuous BP monitoring. This paper aims to introduce a blood pressure monitoring algorithm based on only photoplethysmography (PPG) signals using the deep neural network (DNN). The PPG signals are obtained from 125 unique subjects with 218 records and filtered using signal processing algorithms to reduce the effects of noise, such as baseline wandering, and motion artifacts. The proposed algorithm is based on pulse wave analysis of PPG signals, extracted various domain features from PPG signals, and mapped them to BP values. Four feature selection methods are applied and yielded four feature subsets. Therefore, an ensemble feature selection technique is proposed to obtain the optimal feature set based on major voting scores from four feature subsets. DNN models, along with the ensemble feature selection technique, outperformed in estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) compared to previously reported approaches that rely only on the PPG signal. The coefficient of determination ( R 2 ) and mean absolute error (MAE) of the proposed algorithm are 0.962 and 2.480 mmHg, respectively, for SBP and 0.955 and 1.499 mmHg, respectively, for DBP. The proposed approach meets the Advancement of Medical Instrumentation standard for SBP and DBP estimations. Additionally, according to the British Hypertension Society standard, the results attained Grade A for both SBP and DBP estimations. It concludes that BP can be estimated more accurately using the optimal feature set and DNN models. The proposed algorithm has the potential ability to facilitate mobile healthcare devices to monitor continuous BP.

3.
IUCrJ ; 11(Pt 4): 634-642, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38958016

ABSTRACT

Spectroscopic data, particularly diffraction data, are essential for materials characterization due to their comprehensive crystallographic information. The current crystallographic phase identification, however, is very time consuming. To address this challenge, we have developed a real-time crystallographic phase identifier based on a convolutional self-attention neural network (CPICANN). Trained on 692 190 simulated powder X-ray diffraction (XRD) patterns from 23 073 distinct inorganic crystallographic information files, CPICANN demonstrates superior phase-identification power. Single-phase identification on simulated XRD patterns yields 98.5 and 87.5% accuracies with and without elemental information, respectively, outperforming JADE software (68.2 and 38.7%, respectively). Bi-phase identification on simulated XRD patterns achieves 84.2 and 51.5% accuracies, respectively. In experimental settings, CPICANN achieves an 80% identification accuracy, surpassing JADE software (61%). Integration of CPICANN into XRD refinement software will significantly advance the cutting-edge technology in XRD materials characterization.

4.
Front Oncol ; 14: 1320220, 2024.
Article in English | MEDLINE | ID: mdl-38962264

ABSTRACT

Background: Our previous studies have demonstrated that Raman spectroscopy could be used for skin cancer detection with good sensitivity and specificity. The objective of this study is to determine if skin cancer detection can be further improved by combining deep neural networks and Raman spectroscopy. Patients and methods: Raman spectra of 731 skin lesions were included in this study, containing 340 cancerous and precancerous lesions (melanoma, basal cell carcinoma, squamous cell carcinoma and actinic keratosis) and 391 benign lesions (melanocytic nevus and seborrheic keratosis). One-dimensional convolutional neural networks (1D-CNN) were developed for Raman spectral classification. The stratified samples were divided randomly into training (70%), validation (10%) and test set (20%), and were repeated 56 times using parallel computing. Different data augmentation strategies were implemented for the training dataset, including added random noise, spectral shift, spectral combination and artificially synthesized Raman spectra using one-dimensional generative adversarial networks (1D-GAN). The area under the receiver operating characteristic curve (ROC AUC) was used as a measure of the diagnostic performance. Conventional machine learning approaches, including partial least squares for discriminant analysis (PLS-DA), principal component and linear discriminant analysis (PC-LDA), support vector machine (SVM), and logistic regression (LR) were evaluated for comparison with the same data splitting scheme as the 1D-CNN. Results: The ROC AUC of the test dataset based on the original training spectra were 0.886±0.022 (1D-CNN), 0.870±0.028 (PLS-DA), 0.875±0.033 (PC-LDA), 0.864±0.027 (SVM), and 0.525±0.045 (LR), which were improved to 0.909±0.021 (1D-CNN), 0.899±0.022 (PLS-DA), 0.895±0.022 (PC-LDA), 0.901±0.020 (SVM), and 0.897±0.021 (LR) respectively after augmentation of the training dataset (p<0.0001, Wilcoxon test). Paired analyses of 1D-CNN with conventional machine learning approaches showed that 1D-CNN had a 1-3% improvement (p<0.001, Wilcoxon test). Conclusions: Data augmentation not only improved the performance of both deep neural networks and conventional machine learning techniques by 2-4%, but also improved the performance of the models on spectra with higher noise or spectral shifting. Convolutional neural networks slightly outperformed conventional machine learning approaches for skin cancer detection by Raman spectroscopy.

5.
Sci Rep ; 14(1): 15015, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951589

ABSTRACT

Predicting physical properties of complex multi-scale systems is a common challenge and demands analysis of various temporal and spatial scales. However, physics alone is often not sufficient due to lack of knowledge on certain details of the system. With sufficient data, however, machine learning techniques may aid. If data are yet relatively cumbersome to obtain, hybrid methods may come to the rescue. We focus in this report on using various types of neural networks (NN) including NN's into which physics information is encoded (PeNN's) and also studied effects of NN's hyperparameters. We apply the networks to predict the viscosity of an emulsion as a function of shear rate. We show that using various network performance metrics as the mean squared error and the coefficient of determination ( R 2 ) that the PeNN's always perform better than the NN's, as also confirmed by a Friedman test with a p-value smaller than 0.0002. The PeNN's capture extrapolation and interpolation very well, contrary to the NN's. In addition, we have found that the NN's hyperparameters including network complexity and optimization methods do not have any effect on the above conclusions. We suggest that encoding NN's with any disciplinary system based information yields promise to better predict properties of complex systems than NN's alone, which will be in particular advantageous for small numbers of data. Such encoding would also be scalable, allowing different properties to be combined, without repetitive training of the NN's.

6.
Front Netw Physiol ; 4: 1397151, 2024.
Article in English | MEDLINE | ID: mdl-38983123

ABSTRACT

In this study we focus on two subnetworks common in the circuitry of swim central pattern generators (CPGs) in the sea slugs, Melibe leonina and Dendronotus iris and show that they are independently capable of stably producing emergent network bursting. This observation raises the question of whether the coordination of redundant bursting mechanisms plays a role in the generation of rhythm and its regulation in the given swim CPGs. To address this question, we investigate two pairwise rhythm-generating networks and examine the properties of their fundamental components: cellular and synaptic, which are crucial for proper network assembly and its stable function. We perform a slow-fast decomposition analysis of cellular dynamics and highlight its significant bifurcations occurring in isolated and coupled neurons. A novel model for slow synapses with high filtering efficiency and temporal delay is also introduced and examined. Our findings demonstrate the existence of two modes of oscillation in bicellular rhythm-generating networks with network hysteresis: i) a half-center oscillator and ii) an excitatory-inhibitory pair. These 2-cell networks offer potential as common building blocks combined in modular organization of larger neural circuits preserving robust network hysteresis.

7.
PeerJ Comput Sci ; 10: e2103, 2024.
Article in English | MEDLINE | ID: mdl-38983199

ABSTRACT

Images and videos containing fake faces are the most common type of digital manipulation. Such content can lead to negative consequences by spreading false information. The use of machine learning algorithms to produce fake face images has made it challenging to distinguish between genuine and fake content. Face manipulations are categorized into four basic groups: entire face synthesis, face identity manipulation (deepfake), facial attribute manipulation and facial expression manipulation. The study utilized lightweight convolutional neural networks to detect fake face images generated by using entire face synthesis and generative adversarial networks. The dataset used in the training process includes 70,000 real images in the FFHQ dataset and 70,000 fake images produced with StyleGAN2 using the FFHQ dataset. 80% of the dataset was used for training and 20% for testing. Initially, the MobileNet, MobileNetV2, EfficientNetB0, and NASNetMobile convolutional neural networks were trained separately for the training process. In the training, the models were pre-trained on ImageNet and reused with transfer learning. As a result of the first trainings EfficientNetB0 algorithm reached the highest accuracy of 93.64%. The EfficientNetB0 algorithm was revised to increase its accuracy rate by adding two dense layers (256 neurons) with ReLU activation, two dropout layers, one flattening layer, one dense layer (128 neurons) with ReLU activation function, and a softmax activation function used for the classification dense layer with two nodes. As a result of this process accuracy rate of 95.48% was achieved with EfficientNetB0 algorithm. Finally, the model that achieved 95.48% accuracy was used to train MobileNet and MobileNetV2 models together using the stacking ensemble learning method, resulting in the highest accuracy rate of 96.44%.

8.
Neural Netw ; 179: 106498, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38986183

ABSTRACT

This article provides a unified analysis of the multistability of fraction-order multidimensional-valued memristive neural networks (FOMVMNNs) with unbounded time-varying delays. Firstly, based on the knowledge of fractional differentiation and memristors, a unified model is established. This model is a unified form of real-valued, complex-valued, and quaternion-valued systems. Then, based on a unified method, the number of equilibrium points for FOMVMNNs is discussed. The sufficient conditions for determining the number of equilibrium points have been obtained. By using 1-norm to construct Lyapunov functions, the unified criteria for multistability of FOMVMNNs are obtained, these criteria are less conservative and easier to verify. Moreover, the attraction basins of the stable equilibrium points are estimated. Finally, two numerical simulation examples are provided to verify the correctness of the results.

9.
Neural Netw ; 179: 106501, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38986190

ABSTRACT

In the article, the Mittag-Leffler stability and application of delayed fractional-order competitive neural networks (FOCNNs) are developed. By virtue of the operator pair, the conditions of the coexistence of equilibrium points (EPs) are discussed and analyzed for delayed FOCNNs, in which the derived conditions of coexistence improve the existing results. In particular, these conditions are simplified in FOCNNs with stepped activations. Furthermore, the Mittag-Leffler stability of delayed FOCNNs is established by using the principle of comparison, which enriches the methodologies of fractional-order neural networks. The results on the obtained stability can be used to design the horizontal line detection of images, which improves the practicability of image detection results. Two simulations are displayed to validate the superiority of the obtained results.

10.
EJNMMI Phys ; 11(1): 58, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38977533

ABSTRACT

BACKGROUND: Residual image noise is substantial in positron emission tomography (PET) and one of the factors limiting lesion detection, quantification, and overall image quality. Thus, improving noise reduction remains of considerable interest. This is especially true for respiratory-gated PET investigations. The only broadly used approach for noise reduction in PET imaging has been the application of low-pass filters, usually Gaussians, which however leads to loss of spatial resolution and increased partial volume effects affecting detectability of small lesions and quantitative data evaluation. The bilateral filter (BF) - a locally adaptive image filter - allows to reduce image noise while preserving well defined object edges but manual optimization of the filter parameters for a given PET scan can be tedious and time-consuming, hampering its clinical use. In this work we have investigated to what extent a suitable deep learning based approach can resolve this issue by training a suitable network with the target of reproducing the results of manually adjusted case-specific bilateral filtering. METHODS: Altogether, 69 respiratory-gated clinical PET/CT scans with three different tracers ( [ 18 F ] FDG, [ 18 F ] L-DOPA, [ 68 Ga ] DOTATATE) were used for the present investigation. Prior to data processing, the gated data sets were split, resulting in a total of 552 single-gate image volumes. For each of these image volumes, four 3D ROIs were delineated: one ROI for image noise assessment and three ROIs for focal uptake (e.g. tumor lesions) measurements at different target/background contrast levels. An automated procedure was used to perform a brute force search of the two-dimensional BF parameter space for each data set to identify the "optimal" filter parameters to generate user-approved ground truth input data consisting of pairs of original and optimally BF filtered images. For reproducing the optimal BF filtering, we employed a modified 3D U-Net CNN incorporating residual learning principle. The network training and evaluation was performed using a 5-fold cross-validation scheme. The influence of filtering on lesion SUV quantification and image noise level was assessed by calculating absolute and fractional differences between the CNN, manual BF, or original (STD) data sets in the previously defined ROIs. RESULTS: The automated procedure used for filter parameter determination chose adequate filter parameters for the majority of the data sets with only 19 patient data sets requiring manual tuning. Evaluation of the focal uptake ROIs revealed that CNN as well as BF based filtering essentially maintain the focal SUV max values of the unfiltered images with a low mean ± SD difference of δ SUV max CNN , STD = (-3.9 ± 5.2)% and δ SUV max BF , STD = (-4.4 ± 5.3)%. Regarding relative performance of CNN versus BF, both methods lead to very similar SUV max values in the vast majority of cases with an overall average difference of δ SUV max CNN , BF = (0.5 ± 4.8)%. Evaluation of the noise properties showed that CNN filtering mostly satisfactorily reproduces the noise level and characteristics of BF with δ Noise CNN , BF = (5.6 ± 10.5)%. No significant tracer dependent differences between CNN and BF were observed. CONCLUSIONS: Our results show that a neural network based denoising can reproduce the results of a case by case optimized BF in a fully automated way. Apart from rare cases it led to images of practically identical quality regarding noise level, edge preservation, and signal recovery. We believe such a network might proof especially useful in the context of improved motion correction of respiratory-gated PET studies but could also help to establish BF-equivalent edge-preserving CNN filtering in clinical PET since it obviates time consuming manual BF parameter tuning.

11.
Article in English | MEDLINE | ID: mdl-38980216

ABSTRACT

PURPOSE: To optimise the precision and efficacy of orthokeratology, this investigation evaluated a deep neural network (DNN) model for lens fitting. The objective was to refine the standardisation of fitting procedures and curtail subjective evaluations, thereby augmenting patient safety in the context of increasing global myopia. METHODS: A retrospective study of successful orthokeratology treatment was conducted on 266 patients, with 449 eyes being analysed. A DNN model with an 80%-20% training-validation split predicted lens parameters (curvature, power and diameter) using corneal topography and refractive indices. The model featured two hidden layers for precision. RESULTS: The DNN model achieved mean absolute errors of 0.21 D for alignment curvature (AC), 0.19 D for target power (TP) and 0.02 mm for lens diameter (LD), with R2 values of 0.97, 0.95 and 0.91, respectively. Accuracy decreased for myopia of less than 1.00 D, astigmatism exceeding 2.00 D and corneal curvatures >45.00 D. Approximately, 2% of cases with unique physiological characteristics showed notable prediction variances. CONCLUSION: While exhibiting high accuracy, the DNN model's limitations in specifying myopia, cylinder power and corneal curvature cases highlight the need for algorithmic refinement and clinical validation in orthokeratology practice.

12.
Int Immunopharmacol ; 138: 112608, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38981221

ABSTRACT

BACKGROUND: Abdominal aortic aneurysm (AAA) poses a significant health risk and is influenced by various compositional features. This study aimed to develop an artificial intelligence-driven multiomics predictive model for AAA subtypes to identify heterogeneous immune cell infiltration and predict disease progression. Additionally, we investigated neutrophil heterogeneity in patients with different AAA subtypes to elucidate the relationship between the immune microenvironment and AAA pathogenesis. METHODS: This study enrolled 517 patients with AAA, who were clustered using k-means algorithm to identify AAA subtypes and stratify the risk. We utilized residual convolutional neural network 200 to annotate and extract contrast-enhanced computed tomography angiography images of AAA. A precise predictive model for AAA subtypes was established using clinical, imaging, and immunological data. We performed a comparative analysis of neutrophil levels in the different subgroups and immune cell infiltration analysis to explore the associations between neutrophil levels and AAA. Quantitative polymerase chain reaction, Western blotting, and enzyme-linked immunosorbent assay were performed to elucidate the interplay between CXCL1, neutrophil activation, and the nuclear factor (NF)-κB pathway in AAA pathogenesis. Furthermore, the effect of CXCL1 silencing with small interfering RNA was investigated. RESULTS: Two distinct AAA subtypes were identified, one clinically more severe and more likely to require surgical intervention. The CNN effectively detected AAA-associated lesion regions on computed tomography angiography, and the predictive model demonstrated excellent ability to discriminate between patients with the two identified AAA subtypes (area under the curve, 0.927). Neutrophil activation, AAA pathology, CXCL1 expression, and the NF-κB pathway were significantly correlated. CXCL1, NF-κB, IL-1ß, and IL-8 were upregulated in AAA. CXCL1 silencing downregulated NF-κB, interleukin-1ß, and interleukin-8. CONCLUSION: The predictive model for AAA subtypes demonstrated accurate and reliable risk stratification and clinical management. CXCL1 overexpression activated neutrophils through the NF-κB pathway, contributing to AAA development. This pathway may, therefore, be a therapeutic target in AAA.

13.
Article in English | MEDLINE | ID: mdl-38985412

ABSTRACT

PURPOSE: Decision support systems and context-aware assistance in the operating room have emerged as the key clinical applications supporting surgeons in their daily work and are generally based on single modalities. The model- and knowledge-based integration of multimodal data as a basis for decision support systems that can dynamically adapt to the surgical workflow has not yet been established. Therefore, we propose a knowledge-enhanced method for fusing multimodal data for anticipation tasks. METHODS: We developed a holistic, multimodal graph-based approach combining imaging and non-imaging information in a knowledge graph representing the intraoperative scene of a surgery. Node and edge features of the knowledge graph are extracted from suitable data sources in the operating room using machine learning. A spatiotemporal graph neural network architecture subsequently allows for interpretation of relational and temporal patterns within the knowledge graph. We apply our approach to the downstream task of instrument anticipation while presenting a suitable modeling and evaluation strategy for this task. RESULTS: Our approach achieves an F1 score of 66.86% in terms of instrument anticipation, allowing for a seamless surgical workflow and adding a valuable impact for surgical decision support systems. A resting recall of 63.33% indicates the non-prematurity of the anticipations. CONCLUSION: This work shows how multimodal data can be combined with the topological properties of an operating room in a graph-based approach. Our multimodal graph architecture serves as a basis for context-sensitive decision support systems in laparoscopic surgery considering a comprehensive intraoperative operating scene.

14.
Math Biosci ; : 109248, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38986837

ABSTRACT

The dynamics of locally interacting particles that are distributed in space give rise to a multitude of complex behaviors. However the simulation of reaction-diffusion processes which model such systems is highly computationally expensive, the cost increasing rapidly with the size of space. Here, we devise a graph neural network based approach that uses cheap Monte Carlo simulations of reaction-diffusion processes in a small space to cast predictions of the dynamics of the same processes in a much larger and complex space, including spaces modelled by networks with heterogeneous topology. By applying the method to two biological examples, we show that it leads to accurate results in a small fraction of the computation time of standard stochastic simulation methods. The scalability and accuracy of the method suggest it is a promising approach for studying reaction-diffusion processes in complex spatial domains such as those modelling biochemical reactions, population evolution and epidemic spreading.

15.
J Comput Neurosci ; 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38987452

ABSTRACT

Replicating neural responses observed in biological systems using artificial neural networks holds significant promise in the fields of medicine and engineering. In this study, we employ ultra-fast artificial neurons based on antiferromagnetic (AFM) spin Hall oscillators to emulate the biological withdrawal reflex responsible for self-preservation against noxious stimuli, such as pain or temperature. As a result of utilizing the dynamics of AFM neurons, we are able to construct an artificial neural network that can mimic the functionality and organization of the biological neural network responsible for this reflex. The unique features of AFM neurons, such as inhibition that stems from an effective AFM inertia, allow for the creation of biologically realistic neural network components, like the interneurons in the spinal cord and antagonist motor neurons. To showcase the effectiveness of AFM neuron modeling, we conduct simulations of various scenarios that define the withdrawal reflex, including responses to both weak and strong sensory stimuli, as well as voluntary suppression of the reflex.

16.
Methods Mol Biol ; 2780: 303-325, 2024.
Article in English | MEDLINE | ID: mdl-38987475

ABSTRACT

Antibodies are a class of proteins that recognize and neutralize pathogens by binding to their antigens. They are the most significant category of biopharmaceuticals for both diagnostic and therapeutic applications. Understanding how antibodies interact with their antigens plays a fundamental role in drug and vaccine design and helps to comprise the complex antigen binding mechanisms. Computational methods for predicting interaction sites of antibody-antigen are of great value due to the overall cost of experimental methods. Machine learning methods and deep learning techniques obtained promising results.In this work, we predict antibody interaction interface sites by applying HSS-PPI, a hybrid method defined to predict the interface sites of general proteins. The approach abstracts the proteins in terms of hierarchical representation and uses a graph convolutional network to classify the amino acids between interface and non-interface. Moreover, we also equipped the amino acids with different sets of physicochemical features together with structural ones to describe the residues. Analyzing the results, we observe that the structural features play a fundamental role in the amino acid descriptions. We compare the obtained performances, evaluated using standard metrics, with the ones obtained with SVM with 3D Zernike descriptors, Parapred, Paratome, and Antibody i-Patch.


Subject(s)
Computational Biology , Computational Biology/methods , Antigens/immunology , Binding Sites, Antibody , Antibodies/immunology , Antibodies/chemistry , Humans , Antigen-Antibody Complex/chemistry , Antigen-Antibody Complex/immunology , Protein Binding , Machine Learning , Databases, Protein , Algorithms
17.
Sci Rep ; 14(1): 15541, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38969678

ABSTRACT

Physics-informed neural networks (PINN) have recently become attractive for solving partial differential equations (PDEs) that describe physics laws. By including PDE-based loss functions, physics laws such as mass balance are enforced softly in PINN. This paper investigates how mass balance constraints are satisfied when PINN is used to solve the resulting PDEs. We investigate PINN's ability to solve the 1D saturated groundwater flow equations (diffusion equations) for homogeneous and heterogeneous media and evaluate the local and global mass balance errors. We compare the obtained PINN's solution and associated mass balance errors against a two-point finite volume numerical method and the corresponding analytical solution. We also evaluate the accuracy of PINN in solving the 1D saturated groundwater flow equation with and without incorporating hydraulic heads as training data. We demonstrate that PINN's local and global mass balance errors are significant compared to the finite volume approach. Tuning the PINN's hyperparameters, such as the number of collocation points, training data, hidden layers, nodes, epochs, and learning rate, did not improve the solution accuracy or the mass balance errors compared to the finite volume solution. Mass balance errors could considerably challenge the utility of PINN in applications where ensuring compliance with physical and mathematical properties is crucial.

18.
IEEE Trans Hum Mach Syst ; 54(3): 317-324, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38974222

ABSTRACT

Ultrasound imaging or sonomyography has been found to be a robust modality for measuring muscle activity due to its ability to image deep-seated muscles directly while providing superior spatiotemporal specificity compared to surface electromyography-based techniques. Quantifying the morphological changes during muscle activity involves computationally expensive approaches for tracking muscle anatomical structures or extracting features from brightness-mode (B-mode) images and amplitude-mode (A-mode) signals. This paper uses an offline regression convolutional neural network (CNN) called SonoMyoNet to estimate continuous isometric force from sparse ultrasound scanlines. SonoMyoNet learns features from a few equispaced scanlines selected from B-mode images and utilizes the learned features to estimate continuous isometric force accurately. The performance of SonoMyoNet was evaluated by varying the number of scanlines to simulate the placement of multiple single-element ultrasound transducers in a wearable system. Results showed that SonoMyoNet could accurately predict isometric force with just four scanlines and is immune to speckle noise and shifts in the scanline location. Thus, the proposed network reduces the computational load involved in feature tracking algorithms and estimates muscle force from the global features of sparse ultrasound images.

19.
Cas Lek Cesk ; 162(7-8): 294-297, 2024.
Article in English | MEDLINE | ID: mdl-38981715

ABSTRACT

The advent of large language models (LLMs) based on neural networks marks a significant shift in academic writing, particularly in medical sciences. These models, including OpenAI's GPT-4, Google's Bard, and Anthropic's Claude, enable more efficient text processing through transformer architecture and attention mechanisms. LLMs can generate coherent texts that are indistinguishable from human-written content. In medicine, they can contribute to the automation of literature reviews, data extraction, and hypothesis formulation. However, ethical concerns arise regarding the quality and integrity of scientific publications and the risk of generating misleading content. This article provides an overview of how LLMs are changing medical writing, the ethical dilemmas they bring, and the possibilities for detecting AI-generated text. It concludes with a focus on the potential future of LLMs in academic publishing and their impact on the medical community.


Subject(s)
Neural Networks, Computer , Humans , Natural Language Processing , Language , Publishing/ethics
20.
Int Urol Nephrol ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38982018

ABSTRACT

BACKGROUND: Artificial intelligence (AI) has emerged as a promising avenue for improving patient care and surgical outcomes in urological surgery. However, the extent of AI's impact in predicting and managing complications is not fully elucidated. OBJECTIVES: We review the application of AI to foresee and manage complications in urological surgery, assess its efficacy, and discuss challenges to its use. METHODS AND MATERIALS: A targeted non-systematic literature search was conducted using the PubMed and Google Scholar databases to identify studies on AI in urological surgery and its complications. Evidence from the studies was synthesised. RESULTS: Incorporating AI into various facets of urological surgery has shown promising advancements. From preoperative planning to intraoperative guidance, AI is revolutionising the field, demonstrating remarkable proficiency in tasks such as image analysis, decision-making support, and complication prediction. Studies show that AI programmes are highly accurate, increase surgical precision and efficiency, and reduce complications. However, implementation challenges exist in AI errors, human errors, and ethical issues. CONCLUSION: AI has great potential in predicting and managing surgical complications of urological surgery. Advancements have been made, but challenges and ethical considerations must be addressed before widespread AI implementation.

SELECTION OF CITATIONS
SEARCH DETAIL
...