Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters











Publication year range
1.
Indian J Ophthalmol ; 70(6): 2107-2110, 2022 06.
Article in English | MEDLINE | ID: mdl-35647992

ABSTRACT

Purpose: The present study was performed to compare the optical quality of the eyes of myopic children before and after treatment with atropine eye drops of different concentrations. Methods: In the study population of 71 patients (131 eyes), 34 patients (63 eyes) were given 0.01% atropine eye drops and 37 patients (68 eyes) were given 0.05% atropine eye drops. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs 100%, 20%, and 9%) under different lighting conditions were measured before and after two weeks of atropine treatment. Results: After using 0.05% atropine eye drops for two weeks, the Strehl ratio decreased from 0.27 ± 0.07 to 0.23 ± 0.07 (P = 0.0026), PVA 20% decreased from 1.15 ± 0.32 to 1.03 ± 0.36 (P = 0.0344), and PVA 9% decreased from 0.74 ± 0.23 to 0.64 ± 0.23 (P = 0.0073). The OSI was significantly higher after using 0.05% than 0.01% atropine eye drops (P = 0.0396), while both the Strehl ratio and PVA 20% were lower after using 0.05% than 0.01% atropine eye drops (P = 0.0087 and P = 0.0492, respectively). Conclusion: The children's optical quality did not change significantly after using 0.01% atropine eye drops, whereas it decreased after using 0.05% atropine eye drops.


Subject(s)
Atropine , Myopia , Child , Eye , Humans , Myopia/diagnosis , Myopia/drug therapy , Ophthalmic Solutions , Visual Acuity
2.
BMC Ophthalmol ; 21(1): 292, 2021 Aug 02.
Article in English | MEDLINE | ID: mdl-34340669

ABSTRACT

BACKGROUND: To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. METHODS: 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12 months after surgery. RESULTS: After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1 month were higher after FS-LASIK than SMILE. CONCLUSION: The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. TRIAL REGISTRATION: This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074.


Subject(s)
Astigmatism , Corneal Wavefront Aberration , Keratomileusis, Laser In Situ , Myopia , Astigmatism/surgery , Corneal Stroma , Humans , Lasers, Excimer/therapeutic use , Myopia/surgery , Prospective Studies , Retrospective Studies
3.
Int J Ophthalmol ; 14(3): 371-377, 2021.
Article in English | MEDLINE | ID: mdl-33747811

ABSTRACT

AIM: To analyze postoperative clinical results after implantation of trifocal intraocular lenses (IOLs) in highly myopic eyes with different axial lengths (ALs). METHODS: This retrospective study describes 61 eyes of 44 patients that were implanted with trifocal diffractive IOLs (AT LISA tri 839MP). Twenty-one eyes (15 patients) were included in the AL<26 mm group, 19 eyes (13 patients) in the AL≥26 mm and <28 mm group, and 21 eyes (16 patients) in the AL≥28 mm group. Postoperative outcomes, including corrected and uncorrected distance visual acuity (UDVA), intermediate and near visual acuity at 167 cd/m2 luminance, depth of focus at 85 cd/m2 luminance, and objective optical quality parameters assessed using the Optical Quality Analysis System (OQAS), were compared among the groups at 3mo. RESULTS: There were no significant differences in the mean UDVA, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity (DCNVA) among the three groups (P>0.05). Better near and intermediate visual acuity (from -1.5 D to -3.0 D) were noted on the defocus curve of the AL<26 mm group (P<0.01 vs AL≥28 mm group). Significantly higher objective scatter index (OSI) values and lower modulation transfer function (MTF) cut-off values, Strehl ratio (SR), and OQAS values (OVs) were observed in the AL≥28 mm group (P<0.01 vs AL<26 mm group). All OQAS parameters had statistically significant correlations with DCNVA and visual acuity at the vergence of -2.5 D (P<0.05 to P<0.01). CONCLUSION: Implantation of trifocal IOLs provides good short-term visual and refractive outcomes in highly myopic eyes with different ALs. However, the near vision decreases in the extremely myopic eyes at lower luminance, which is associated with the lower objective optical quality in these eyes.

4.
Int Ophthalmol ; 40(11): 2995-3004, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32617802

ABSTRACT

PURPOSE: To explore objective visual quality in dry eye diseases (DED) and the correlation between corneal nerves and objective visual quality. METHODS: Ninety-eight eyes of 49 patients with DED were included. Each patient was evaluated with the ocular surface disease index (OSDI), eyelid margin signs and meibomian gland assessments; corneal staining; tear film breakup time (TBUT); tear meniscus height (TMH); in vivo confocal microscopic (IVCM); objective visual quality including the objective scatter index (OSI), mean objective scattering index (mOSI), modulation transfer function (MTF) cutoff value and Strehl ratio. RESULTS: A significant correlation was found between the OSDI and mOSI (r = 0.422, p = 0.005), MTF cutoff value (r = - 0.355, p = 0.020), and Strehl ratio (r = - 0.446, p = 0.003). The OSI was significantly correlated with TBUTf (r = - 0.213, p = 0.042). The mOSI, MTF cutoff value, Strehl ratio were correlated with eyelid margin signs and meibomian assessments. Additionally, there was a statistically significant correlation between corneal nerve length and the mOSI (r = - 0.239, p = 0.037), OSI (r = - 0.294, p = 0.028), MTF cutoff value(r = 0.282, p = 0.012), and Strehl ratio (r = 0.299, p = 0.008). CONCLUSIONS: Our study explored that objective visual quality was correlated with clinical symptoms and signs in DED patients. Furthermore, for the first time, our study explored the relationship between corneal nerves and objective visual quality and discovered that longer and wider corneal nerves were associated with better objective visual quality, which suggested that nerve changes may be a factor that related to poor visual quality in DED patients.


Subject(s)
Dry Eye Syndromes , Tears , Cornea , Dry Eye Syndromes/diagnosis , Humans , Meibomian Glands , Prospective Studies
5.
BMC Ophthalmol ; 20(1): 82, 2020 Mar 04.
Article in English | MEDLINE | ID: mdl-32131800

ABSTRACT

BACKGROUND: The current study compared optical quality before and after implantation of a posterior chamber phakic intraocular lens with a central hole [V4c implantable collamer lens (ICL)] under bright and dark lighting conditions by means of the Optical Quality Analysis System™ (OQAS; Visiometrics, Terrassa, Spain). METHODS: This prospective study involved 91 eyes of 46 consecutive high myopia patients (15 males and 31 females, average spherical equivalent - 10.50 ± 0.33D) undergoing implantation of a V4c ICL. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs; 100, 20, and 9%), under different lighting conditions, were measured before and 1 week, 1 month, and 3 months after surgery. RESULTS: All optical parameters showed significant improvements, at all time points, under dark condition after surgery. We observed no significant changes in PVA 9% at 1 week (mean value 0.539, P = 0.12) or 1 month after surgery (mean value 0.573, P = 0.08) under bright condition; but all other postoperative parameters improved significantly. Comparing the two lighting conditions, the OSI decreased more under dark conditions at 1 week (P = 0.02), 1 month (P = 0.004), and 3 months (P = 0.002), but there was no significant difference in any other parameter. In addition, patients were divided into super high myopia (group S, spherical equivalent greater than - 10 D) and high myopia (group H, spherical equivalent from - 6 D to - 10 D), the group S improved significantly more than group H in all parameters, under both bright and dark conditions. CONCLUSIONS: V4c ICL implantation improved optical quality under both bright and dark lighting conditions, and had a better ability to reduce the extent of scattering in the dark. Furthermore, group S achieved greater improvement in visual quality, which should be considered by physicians before surgery.


Subject(s)
Lens Implantation, Intraocular/methods , Lighting , Myopia/surgery , Optics and Photonics , Phakic Intraocular Lenses , Refraction, Ocular/physiology , Visual Acuity , Adolescent , Adult , Biometry , Female , Follow-Up Studies , Humans , Male , Myopia/physiopathology , Postoperative Period , Prospective Studies , Prosthesis Design , Young Adult
6.
BMC Ophthalmol ; 19(1): 152, 2019 Jul 18.
Article in English | MEDLINE | ID: mdl-31319806

ABSTRACT

BACKGROUND: To compare the postoperative optical quality in eyes with customized selection and random selection of aspheric intraocular lens (IOL) implantation. METHODS: A prospective, nonrandomized study was implemented in adult cataract patients who underwent unilateral phacoemulsification with aspheric IOL implantation. Patients were allocated into two treatment groups: a customized group and a control group. In the customized group, the aspheric IOL selection was based on the corneal spherical aberration to enable the postoperative target ocular spherical aberration closest to zero; in the control group, the aspheric IOLs were chosen using a random strategy. Primary outcome measurements included the following objective optical quality assessments: higher-order aberrations obtained by a Hartmann-shack aberrometer at 4 mm and 6 mm pupil diameters; objective scatter index (OSI), modulation transfer function (MTF) cut-off, Strehl ratio (SR) and a simulated contrast visual acuity-optical quality analysis system value (OV) obtained by a double-pass system with a 4-mm aperture. Subjective visual acuity was measured as secondary outcome. All the patients were followed up for 3 months. RESULTS: Eighty-four patients in the customized group and 78 patients in the control group were evaluated. There was no significant difference in postoperative visual acuity between the two groups (P > 0.05). Significantly less ocular higher-order aberrations were shown in the customized group (P < 0.05). No significant difference was shown in OSI, MTF cut-off, SR and OV between the two groups (P > 0.05). CONCLUSIONS: Although customized selection of aspheric IOL implantation showed less postoperative ocular aberrations, it performed similarly to random selection of aspheric IOL implantation in terms of postoperative visual acuity, simulated contrast visual acuity, intraocular scatter, modulation transfer function and Strehl ratio. TRIAL REGISTRATION: Retrospectively registered on 07/06/2019. Registration number: ChiCTR1900024356 .


Subject(s)
Cataract/physiopathology , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Phacoemulsification , Adult , Aged , Case-Control Studies , Contrast Sensitivity/physiology , Corneal Wavefront Aberration/physiopathology , Female , Humans , Middle Aged , Prospective Studies , Prosthesis Design , Visual Acuity
7.
Transl Vis Sci Technol ; 7(4): 5, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30009091

ABSTRACT

PURPOSE: We evaluated the relationship between ocular surface clinical tests and quality of vision in patients with dry eye disease (DED). METHODS: In this study, 136 eyes of 72 dry eye patients were evaluated retrospectively using the ocular surface disease index (OSDI), measurement of tear film break-up time (TBUT), the Oxford score, Van Bijsterveld score, and Schirmer I test. Quality of vision was assessed with the optical quality analysis system (OQAS) using the objective scatter index (OSI) recorded over 20 seconds without blinking. Correlations between dry eye symptoms and signs, and OSI measurements were evaluated. RESULTS: The OSI and OSI standard deviation (OSI SD) were correlated with TBUT (r = -0.21, P = 0.013 and r = -0.18, P = 0.038, respectively), Oxford score (r = 0.31, P = 0.0002 and r = 0.18, P = 0.032, respectively), and the Van Bijsterveld score (r = 0.33, P = 0.0001 and r = 0.25, P = 0.003, respectively). The OSI also was correlated with the Schirmer test (r = -0.19, P = 0.025), OSDI (r = 0.17, P = 0.04), and the ocular symptoms subscale of the OSDI (r = 0.21, P = 0.01). OSI SD was correlated with the environmental triggers subscale of the OSDI (r = 0.21, P = 0.016). CONCLUSIONS: Quality of vision measured with the OQAS was correlated with dry eye symptoms and signs. The OQAS could be a useful tool to better evaluate visual function in patients with DED. TRANSLATIONAL RELEVANCE: The OQAS provides a better understanding of patient complaints about alteration of vision quality. It might be useful to integrate this objective system in severity assessments and follow-up of DED, especially for treatment evaluations.

8.
Journal of Medical Postgraduates ; (12): 163-168, 2018.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-700794

ABSTRACT

Objective Systemic lupus erythematosus (SLE) cause irreversible damage to multiple organs of the body.This article evaluates the changes in tear film quality and visual quality in patients with SLE.Methods In the study,we selected 66 patients with SLE (66 right eyes) for the study group and 59 healthy volunteers (59 right eyes) for the control group,The measurements of BUT,corneal fluorescein staining(FL) score and SIt were taken in turn for both two groups.Anterior segment OCT was used for measuring the CET,CCT,TMD,TMH and TMA.OQAS Ⅱ system was taken for MTFcutoff,SR,static OSI,OV (100%,20%,9%) and dynamic OSI.Differences of the parameters were compared between the two groups.The data correlation was assessed by Spearman rank correlation analysis.Results There were significant differences in SIt,BUT,FL score,CET,TMH,TMD and TMA between the two groups(P<0.05),but no significant difference in CCT (P>0.05).The differences of static OSI,MTFcutoff,SR,OV100%,OV20%,OV9% between the two groups were statistically significant(P<0.01).The △OSI(differences between dynamic and static OSI) had the difference between the two groups(t=4.615,P<0.001).TMA was positively correlated with CET,SIt,and BUT (P<0.05),and had no correlation with OSI,MTFcutoff,SR,OV100%,OV20%,OV9% (P>0.05).Anti-ds-DNA is positively correlated with SIt,TMA,MTFcutoff and SR (r =0.346,0.208,0.257,0.197,P<0.05) and negatively correlated with OSI(r=-0.292,P<0.05).There was no correlation between ANA,C3,C4 and the parameters of tear film and visual quality (P>0.05).Conclusion SLE may affect the amount and stability of the patient's tears and affects the corneal epithelial thickness and visual quality.

9.
International Eye Science ; (12): 1090-1094, 2017.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-641217

ABSTRACT

Orthokeratology is a kind of rigid contact lens which have reverse geometric desi, with higher oxygen permeability and security.Overnight wearing of orthokeratology can decrease the central corneal curvature and increase peripheral corneal curvature by flatting the central department of corneal, thus reduce the refraction of myopia.Through a period of time of wearing orthokeratology lens, patients can obtain good eyesight without frame glasses.Insisting on wearing orthokeratology lens can control the development of myopia.Orthokeratology is widely applied in the control of juvenile myopia, so we need scientific evaluation system to measure the visual quality after wearing orthokeratology lens.Here are the methods that used to evaluate the visual quality after wearing orthokeratology lens.

10.
J Fr Ophtalmol ; 37(7): 540-7, 2014 Sep.
Article in French | MEDLINE | ID: mdl-25059995

ABSTRACT

PURPOSE: To assess quality of vision by measuring ocular light scattering with two platforms and comparing them to traditional tests, in healthy subjects and cataract patients. PATIENTS AND METHODS: One hundred and sixty-eight eyes divided in two groups were examined by the same clinician in a prospective study (group 1, healthy controls, with a mean age of 31.22 [± 6.76]; and group 2, patients presenting with cataract, with a mean age of 60.36 [± 10.27]). Patients with ocular surface disease were excluded from this study. Each group responded to the VF-14 questionnaire, underwent an examination with lens opacities assessed by LOCS III and a measurement of ocular light scattering with two platforms: the OQAS (Visiometrics(©)) and the C-Quant (Oculus(©)). We analyzed correlations between indices of light scattering with the two platforms (respectively OSI and log(s)) and traditional quality of vision tests (VF-14 questionnaire and LOCS III). RESULTS: Strong correlations were found between the OSI and LOCS III. Moderate correlations were found between the OSI and the VF-14 questionnaire, as well as between log(s), VF-14 questionnaire and LOCS III. CONCLUSION: Indices of light scattering seems to be valid tools to assess quality of vision, thus lending themselves to routine testing of visual function.


Subject(s)
Cataract/physiopathology , Diagnostic Techniques, Ophthalmological/instrumentation , Light , Scattering, Radiation , Visual Acuity/physiology , Adult , Aged , Aged, 80 and over , Case-Control Studies , Humans , Middle Aged , Prospective Studies , Young Adult
11.
J Fr Ophtalmol ; 37(3): 188-94, 2014 Mar.
Article in French | MEDLINE | ID: mdl-24560942

ABSTRACT

PURPOSE: To assess the functional impact of the severity of dry eye on the quality of vision by measuring an Objective Scatter Index (OSI) using double pass aberrometry. PATIENTS AND METHODS: Twenty-eight patients (56 eyes) with dry eye syndromes of varying severity participated in this study. A double-pass aberrometer was used to measure the dynamic changes in the OSI for 20 seconds. The mean and standard deviations of the OSI and the number of blinks occurring during the examination were compared as a function of the clinical severity of dry eye disease. RESULTS: The mean OSI increased with the severity of dry eye syndrome with a significant difference for stages 3 (P<0.01) and 4 (P<0.001) compared to stages 1 and 2, without a significant difference based on age (P>0.8) or visual acuity (P>0.2). Standard deviation of the OSI also increased with the severity of dry eye disease, with a significant difference for stages 3 (P<0.01) and 4 (P<0.0001) compared to stages 1 and 2, with no significant increase in the number of blinks (P>0.2). The values of the OSI standard deviation represented the dynamic nature of aberrometric changes related to the instability of the tear film. CONCLUSION: Quality of vision of patients deteriorated in relation to the severity of their dry eye. The analysis of OSI standard deviation appears to be an objective way to assess the intensity of subjective visual disturbances reported by patients with dry eye syndrome. It also provides a new tool to assess the severity of damage to the ocular surface.


Subject(s)
Aberrometry , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/physiopathology , Vision, Ocular , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Severity of Illness Index
12.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-53712

ABSTRACT

PURPOSE: To evaluate the efficacy of Optical Quality Analysis System (OQAS(R)) instrument for the assessment of dry eye syndrome. METHODS: Dynamic recording of double-pass (DP) retinal images was performed in 1 eye dry eye patients (20 eyes) and in healthy controls (20 eyes) for 20 seconds after eye blinking. RESULTS: The mean objective scatter Index (OSI) value was 4.53 in dry eyes, 0.67 in healthy eyes and the standard deviation of OSI was 1.20 in dry eyes and 1.18 in healthy eyes. The patients with dry eyes showed significantly higher mean OSI and standard deviation values. Ocular scatter increased over time and significant changes occurred 13.5 seconds after blinking. The difference in OSI value between 0 second and 20 seconds was significantly greater in dry eye patients (4.15) than in controls (0.32). CONCLUSIONS: Ocular scatter increased over time after blinking. The dry eye patients had larger and more variable ocular scatter index than the controls. OQAS(R) may be useful to detect and follow-up tear film-related patient complaints in dry eye syndrome.


Subject(s)
Humans , Blinking , Dry Eye Syndromes , Retinaldehyde , Tears
13.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-53713

ABSTRACT

PURPOSE: To evaluate the change of visual quality after wearing orthokeratology lenses overnight. METHODS: This study included 13 patients (24 eyes) who wore orthokeratology lenses for the first time. Visual quality was assessed with the optical quality analysis system (OQAS) using the double-pass technique. The value of modulation transfer function (MTF) cutoff, Strehl ratio, and objective scatter index (OSI) were measured at baseline and 4 weeks after wearing the lenses. RESULTS: The mean spherical equivalent decreased from -2.70 +/- 1.03 diopters (D) to 0.03 +/- 0.36 D after 4 weeks of wearing orthokeratology lenses and uncorrected visual acuity improved from log MAR 0.88 +/- 0.17 to log MAR 0.03 +/- 0.04. The MTF cutoff decreased from 38.20 +/- 11.01 to 34.79 +/- 10.30 and the Strehl ratio decreased from 0.24 +/- 0.07 to 0.21 +/- 0.07 but without statistical significance. The OSI significantly increased from 0.38 +/- 0.19 to 0.72 +/- 0.40 after wearing orthokeratology lenses. CONCLUSIONS: Orthokeratology lenses were effective for correction of myopia and astigmatism. The OSI increased after wearing the lenses, but MFT cutoff and Strehl ratios were not affected.


Subject(s)
Humans , Astigmatism , Myopia , Visual Acuity
14.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-150674

ABSTRACT

PURPOSE: To investigate the results using the OQAS and the Pentacam in cataract patients classified according to the type of lens opacity. METHODS: The present study included 124 eyes of 92 patients who had cataract surgery at Seoul St. Mary's Hospital from December 2011 to January 2012 and were classified into nuclear, cortical, and posterior subcapsular cataract patients. The lens opacity was determined with OSI, MTF, Strehl ratio, width 10%, width 50% and the opacity of Scheimpflug image by the OQAS and the Pentacam. Additionally, the correlation between subjective cataract classification and objective opacity value was analyzed. RESULTS: The nuclear cataract group showed a 6.40 +/- 2.41 OSI value and had high opacity. The cortical cataract group showed the highest MTF cut-off value (12.02 +/- 6.19 C/deg). When evaluating Pentacam results, the posterior subcapsular cataract group had the lowest average level of lens opacity (9.12 +/- 1.08) followed by in increasing order, the cortical cataract group (9.79 +/- 1.67) and the nuclear cataract group (11.08 +/- 1.84). The results were statistically significant (p < 0.001). The OSI value of the OQAS was significantly correlated with nuclear and posterior opacity (p = 0.049, p = 0.039, respectively) except cortical opacity (p = 0.781). MTF and nuclear opacity showed statistically significant correlation and the lens opacity of Pentacam was correlated with nuclear and posterior opacities. In cortical cataract with severe peripheral opacity, the cortical opacity showed significant correlation with Maximum. CONCLUSIONS: The OQAS and Pentacam results showed high correlation with the nuclear and posterior opacities which can be useful for cataract surgery.


Subject(s)
Humans , Cataract , Classification , Seoul
15.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-197757

ABSTRACT

PURPOSE: To evaluate objectively the improvement level of a patient's visual function using the NEI-VFQ-25 questionnaire pre- and post-operatively and the OQAS results from the patient group who had the same corrected visual acuity pre- and post-operatively. METHODS: We examined and compared the NEI-VFQ-25 test, OSI, MTF cut-off, strehl ratio, OQAS, and width at 50% and 10% in 24 eyes of 24 patients who had cataract surgery between December 2011 and February 2012. The patients' corrected visual acuity in both eyes had no change (0.8 and 0.8) pre-operatively and 2 months post-operatively (1.0 and 1.0). RESULTS: The satisfaction level regarding the patients' visual function increased. The NEI-VFQ-25 test was 71.54 +/- 14.88 points pre-operatively and 85.70 +/- 6.17 points post-operatively. OSI decreased to 3.13 +/- 1.66 (OSI value) and 1.53 +/- 0.58 (OSI value), and MTF cut off value improved from 14.51 +/- 6.97 (C/deg) to 27.63 +/- 8.98 (C/deg). Strehl ratio was improved to 0.09 +/- 0.03 and 0.14 +/- 0.03, width at 50% improved to 8.44 +/- 3.73 and 4.52 +/- 1.90 and width at 10% improved to 35.30 +/- 15.22 and 18.04 +/- 8.87 pre- and post-operatively, respectively. CONCLUSIONS: The NEI-VFQ-25 test reflected the vision improvement in patients where after cataract surgery, determination of the visual function improvement only through vision would not be possible. In addition, the OQAS showed the quality of vision improved through quantified values.


Subject(s)
Humans , Cataract , Eye , Phacoemulsification , Surveys and Questionnaires , Vision, Ocular , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL