Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 91
Filter
1.
J Clin Med ; 13(13)2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38999412

ABSTRACT

Background/Objectives: This study aims to analyze the efficacy and safety of the two pelvic fixation systems, S-hooks (SH) and lumbar-sacral-alar-iliac (SAI) screws, when used in association with magnetically controlled growing rods (MCGRs) in non-ambulatory children with severe neuromuscular scoliosis (NMS). Methods: Forty-one patients were retrospectively examined and subdivided corresponding to ilium hook fixation or SAI screws. The major curve correction (%) and pelvic obliquity (PO) correction (%) were assessed utilizing scoliosis plain film radiographs over time. Complications and unplanned return to the operating room (UPROR) were recorded. Patient-specific pre- and postoperative values were included in a backward stepwise regression model to assess UPROR. Results: Mean age at index intervention was 9.4 years. Preoperative main curve was 81° and PO was 22°. 21 and 20 patients were categorized into the SH and SAI subgroups, respectively. Initial curve correction was significantly better in the SAI subgroup (63 vs. 42% in the SH, p = 0.045), while PO correction was equally good. Curve and PO correction were maintained throughout the follow-up period of 55 months. UPROR rate was 38% in the SH subgroup, and 5% in the SAI subgroup (p = 0.010). Regression analysis identified postoperative curve correction as predictive value for UPROR (p = 0.006). Conclusions: SAI screw fixation has a low UPROR rate and achieves superior curve correction. S-hooks are a viable option to correct PO and NMS in children with high operative risk to reduce operative time, but revision surgery is not uncommon.

2.
Trauma Case Rep ; 51: 101018, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38628458

ABSTRACT

The surgical management of patellar fractures typically yielded satisfactory results; however, in situations involving multifragmented patellar fractures or those affecting the inferior pole, it became imperative to employ alternative osteosynthesis techniques that enhanced stability, enabled early rehabilitation initiation, prevented implant failure, and avoided reduction loss before fracture consolidation. In this context, an unconventional osteosynthesis alternative was presented, utilizing an anatomically designed hook plate originally intended for the fifth metatarsal. This technique was successfully applied in three patients with multifragmentary patellar fractures, allowing stable fixation of small or marginal fragments through the plate's hooks without compromising vascularity. Fracture consolidation was achieved without reduction loss, and owing to its low profile, patient discomfort and irritation were minimized compared to traditional tension band or wiring techniques. This approach suggested the potential to forego early plate removal, thereby contributing to a more effective management of patellar fractures. Level of evidence: IV.

3.
Cir Cir ; 2024 Feb 12.
Article in Spanish | MEDLINE | ID: mdl-38346348

ABSTRACT

Objective: To describe the use of negative pressure therapy with (TPNi) and without instillation (TPNs) as adjuvant treatment in the management of orthopedic device-associated infections (IADO). Method: Analytic observational study of records of patients with IADO managed with TPNi and TPNs with 0.9% saline solution, in patients > 18 years, operated on in 2018-2021. Clinical characteristics of infection, infectious agent as well as sociodemographic variables were evaluated. TPN was performed with the V.A.C. VERAFLO™ system. Analysis with χ2, Fisher and t-Student. Statistically accepted value p < 0.05. Results: Sample 40 patients. 75% male. Fractures 42.5% exposed and 57.5% closed. 92.5% applied prophylactic antibiotic (30-120 min). 35% plate implants, 12.5% centromedullary nail, 10% knee prosthesis and 12.5% hip. 47.5% bleeding < 500 ml. 72.5% surgical time of 2-4 hours. Previous hospitalization time, TPNs 3 weeks 55.9% and 4 weeks 26.5%; TPNi, 3 weeks 50% and 4 weeks 33.3%. Conservation of the implant 73.5% TPNs and 50% TPNi (p = 0.341). Wound closure 91.2% with TPNs and 100% with TPNi (p = 1.000). Conclusions: The use of TPNs and TPNi were useful as adjuvant treatments in the management of IADO, in addition they allowed to preserve the implant and wound closure in a large part of the patients.


Objetivo: Describir el uso de la terapia de presión negativa con (TPNi) y sin instilación (TPNs) como tratamiento adyuvante en el manejo de infecciones asociadas a dispositivo ortopédico (IADO). Método: Estudio observacional analítico de expedientes de pacientes con IADO manejados con TPNi y TPNs con solución salina al 0.9%, mayores de 18 años, operados en el periodo 2018-2021. Se evaluaron las características clínicas de infección, el agente infeccioso y las variables sociodemográficas. La TPN se realizó con sistema V.A.C.VERAFLO™. Para los análisis se emplearon las pruebas χ2, Fisher y t de Student. Valor estadísticamente aceptado: p < 0.05. Resultados: La muestra fue de 40 pacientes, el 75% masculinos. Fracturas: 42.5% expuestas y 57.5% cerradas. En el 92.5% se aplicó antibiótico profiláctico (30-120 min). Implantes: 35% placas, 12.5% clavo centromedular, 10% prótesis de rodilla y 12.5% cadera. El 47.5% con sangrado < 500 ml. En el 72.5% un tiempo quirúrgico de 2-4 horas. Tiempo de hospitalización previa: TPNs 3 semanas 55.9% y 4 semanas 26.5%; TPNi 3 semanas 50% y 4 semanas 33.3%. Conservación del implante: 73.5% TPNs y 50% TPNi (p = 0.341). Cierre de herida: 91.2% con TPNs y 100% con TPNi (p = 1.000). Conclusiones: El uso de TPNs y TPNi fue útil como tratamiento adyuvante en IADO, y además permitieron conservar el implante y el cierre de la herida en la mayoría de los pacientes.

4.
HardwareX ; 16: e00474, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37771322

ABSTRACT

Screw insertion torque is a widely used/effective method for quantifying fixation strength in orthopedic implant research for different screw geometries, implantation sites, and loads. This work reports the construction of an open-source instrumented benchtop screw insertion device for a total cost of $7545 ($492 + $7053 for equipped sensors), as well as validation of the device and an example use-application. The insertion device is capable of recording the axial load, rotational speed, and applied torque throughout the screw insertion process at 10 samples per second, as demonstrated in the validation test. For this combination of bone analog (20 PCF Sawbones©), screw, and loading, the resolution of the torque sensor was 25% of the maximum measured torque; a different model torque sensor would be required to meet ASTM F543-17, which specifies a resolution of 10% of the maximum torque. This system is optimized for fastener insertion at speeds of 120 rpm or less and axial loading up to 50 N.

5.
Arch Bone Jt Surg ; 11(8): 503-509, 2023.
Article in English | MEDLINE | ID: mdl-37674697

ABSTRACT

Objectives: This study investigates outcomes and complications of the pin and plate fixation technique, which was suggested for distal humerus fractures. It also reports the results of its application in nonunions for the first time. Methods: Forty-nine fracture and 17 nonunion cases who underwent surgery using the technique and were followed for at least 18 months were assessed through the range of motion (ROM), Quick Disabilities of the Arm, Shoulder, and Hand Score (Quick-DASH), Mayo Elbow Performance Score (MEPS), four-category verbal rating scale (VRS-4), and complications. Results: At the last follow-up, the mean scores of flexion, extension deficit, supination, and pronation ranges in fracture cases were 116.7, 22.9, 90.0, and 90.0 degrees, respectively. These values in nonunion cases were 112.2, 26.4, 86.7, and 85.5 degrees, respectively. The average ROM in fracture cases was 93.8, while it was 85.8 degrees in nonunion cases. The mean Quick-DASH in fracture and nonunion patients were 25.2 and 31.1, respectively. According to the MEPS, 77.5% of fracture and 64.7% of nonunion patients had excellent and good results. In fracture cases, the mean scores of VRS-4 at rest, light activity, and hard activity were 1.3, 1.8, and 2.3, respectively. These values in nonunion cases were 1.8, 2.2, and 2.5, respectively. The most common complications were device prominence and ulnar neuropathy. Conclusion: An acceptable union rate and proper elbow function can be expected by using this technique. Owing to the promising results of this study, further high-quality studies are recommended. Hereby this technique is called Persian Fixation.

6.
Rev. venez. cir. ortop. traumatol ; 55(1): 29-37, jun. 2023. ilus, graf
Article in Spanish | LILACS, LIVECS | ID: biblio-1512029

ABSTRACT

Las fracturas supracondíleas en niños se asocian con algunas complicaciones. Su tratamiento estándar es la reducción cerrada y la fijación con alambres en distintas configuraciones. Se realizó un estudio observacional, analítico, prospectivo y longitudinal con pacientes pediátricos que ingresaron con fracturas supracondíleas de húmero tratados quirúrgicamente con alambres de Kirschner con "Técnica Cruzada" en el Hospital Central San Cristóbal enero a junio de 2022. Se incluyeron 30 pacientes. La edad promedio fue 6,3±2,2(3-10) años. La causa más frecuente del traumatismo fue la precipitación de altura en 63,3% de los casos. La posición del codo al momento del accidente fue en extensión en 90%. Todas las fracturas fueron cerradas. El tiempo promedio desde el accidente hasta su atención en emergencia fue de 8,5±13,4(2-72) horas. Los signos clínicos más frecuentes fueron dolor en 100,0%, limitación funcional en 96,7%, aumento de volumen 73,3% y deformidad 50,0%. Según la clasificación AO la más frecuente fue del tipo 13-M/3. 1 III en el 50% de los casos y según Gartland, las tipo IIIA en 53,3%. A las 4 semanas, 100,0% de las fracturas consolidaron, 13,3% presentó valgo y 6,7% varo en la radiografía anteroposterior. Mientras que, en la lateral, 33,3% antecurvatum. La media del ángulo de Baumann fue de 20,27±1,39 grados. La tasa de complicaciones fue de 16,66%, 2(6,7%) casos presentaron neuropraxia y 3(10,0%) granuloma. En conclusión, la Técnica Cruzada es segura en términos de reducción, funcionalidad y tasas de complicaciones en el seguimiento a medio plazo(AU)


Supracondylar fractures in children are associated with some complications. Its standard treatment is closed reduction and fixation with wires in different configurations. An observational, analytical, prospective and longitudinal study was made, with pediatric patients admitted with supracondylar humeral fractures surgically treated with Kirschner wires with the "Cross Technique" at the Hospital Central San Cristóbal from January to June 2022. 30 patients were included. The mean age was 6,3±2,2(3-10) years. The most frequent cause of trauma was high altitude precipitation in 63,3% of the cases. The position of the elbow at the time of the accident was 90% extended. All fractures were closed. The mean time from the accident to emergency care was 8,5±13,4(2-72) hours. The most frequent clinical signs were pain in 100,0%, functional limitation in 96.7%, volume increase in 73,3%, and deformity in 50,0%. According to the AO classification, the most frequent was type 13-M/3. 1 III in 50% of cases and according to Gartland, type IIIA in 53,3%. At 4 weeks, 100,0% of the patients consolidated, 13,3% presented valgus and 6,7% varus on the anteroposterior radiograph. While, on the side, 33,3% antecurvatum. The mean Baumann angle was 20,27 ± 1.39 degrees. The rate of complications was 16,66%, 2 (6,7%) cases presented neuropraxia and 3 (10,0%) granuloma. In conclusion, the Crossover Technique is safe in terms of reduction, functionality, and complication rates in medium-term follow-up(AU)


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Closed Fracture Reduction , Fractures, Closed , Humeral Fractures, Distal , Pain
7.
J Orthop Surg Res ; 18(1): 392, 2023 May 30.
Article in English | MEDLINE | ID: mdl-37254205

ABSTRACT

BACKGROUND: To investigate the possibility of silver (Ag)-induced adverse events and the degree of bone fusion in posterior lumbar interbody fusion surgery using an Ag-containing hydroxyapatite (HA) lumbar interbody cage. METHODS: An Ag-HA cage consisting of highly osteoconductive HA interfused with Ag was developed, and we applied it clinically at three university-affiliated hospitals from April 2020 to December 2020. During the 12-month postoperative observation period, Ag-related adverse events, neuropathy, and postoperative complications were investigated as indicators of safety, while clinical improvement and the fusion status were investigated as indicators of efficacy. Clinical improvement was defined as improvement beyond the minimum clinically important difference (MCID) in the numerical rating scale (NRS; 1.6) for low back and lower limb pain and the Oswestry Disability Index (ODI; 12.8). RESULTS: We performed lumbar interbody fusion using an Ag-HA cage for 48 patients (female, n = 25; mean age, 67.5 years). The mean preoperative NRS was 6.4 (standard deviation, 1.9), while the mean preoperative ODI was 44 [12]. No adverse effects (i.e., argyria) were identified during the 12-month observation period. Surgical site infection occurred in one case, although the implant was preserved via immediate debridement. In total, 39 (81%) participants showed clinical improvement beyond MCID for both NRS and ODI. Bone fusion was achieved at 45 levels (88%) at 6 months and 48 levels (91%) at 12 months postoperatively. CONCLUSIONS: The results of this study suggest that Ag-HA cages can be safely used in spinal fusion procedures and have the potential to prevent postoperative infections, prevent deterioration of the quality of life, and result in favorable outcomes. Larger-scale and longer-term follow-up studies will be required to corroborate these conclusions. Trial registration UMIN 000039964 (date: April 01, 2020).


Subject(s)
Silver , Spinal Fusion , Humans , Female , Aged , Treatment Outcome , Durapatite , Quality of Life , Spinal Fusion/adverse effects , Spinal Fusion/methods , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Retrospective Studies
8.
J Back Musculoskelet Rehabil ; 36(4): 941-946, 2023.
Article in English | MEDLINE | ID: mdl-37248879

ABSTRACT

BACKGROUND: Previous studies have reported altered neural activity in the motor cortex after short-term cast immobilization, even in healthy participants. However, the effects of short-term movement restriction on tissue structure are not well understood. OBJECTIVE: To investigate the effects of short-term lower limb immobilization on muscle tissue hardness. METHODS: Seventeen healthy participants were enrolled in the study. Each participant's non-dominant lower limb was fixed with a soft bandage and medical splint for 10 h. Gastrocnemius muscle tissue hardness was measured using a tissue hardness meter before cast application and immediately after cast removal. Measurements were performed five times for each lower limb, and the three values with the lowest coefficient of variance were adopted as the value of muscle tissue hardness. RESULTS: Gastrocnemius muscle tissue hardness in the immobilized limb was lower after cast removal than that before cast application (from 53.6 to 51.8; p< 0.01), whereas the non-fixed limb showed an increase in muscle tissue hardness at the end of the experiment (from 52.9 to 54.3; p= 0.03). CONCLUSION: The findings indicate that 10 h movement restriction induced a reduction in muscle tissue hardness, suggesting acute adverse effects of cast immobilization for orthopedic treatment.


Subject(s)
Leg , Muscle, Skeletal , Humans , Adult , Hardness , Muscle, Skeletal/physiology , Lower Extremity
9.
Skeletal Radiol ; 52(3): 393-404, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35536358

ABSTRACT

Carbon-fiber-reinforced polyetheretherketone (CFR-PEEK) orthopedic implants are gaining popularity in oncologic applications as they offer many potential advantages over traditional metallic implants. From an imaging perspective, this instrumentation allows for improved evaluation of adjacent anatomic structures during radiography, computed tomography (CT), and magnetic resonance imaging (MRI). This results in improved postoperative surveillance imaging quality as well as easier visualization of anatomy for potential image-guided percutaneous interventions (e.g., pain palliation injections, or ablative procedures for local disease control). CFR-PEEK devices are also advantageous in radiation oncology treatment due to their decreased imaging artifact during treatment planning imaging and decreased dose perturbation during radiotherapy delivery. As manufacturing processes for CFR-PEEK materials continue to evolve and improve, potential orthopedic applications in the spine and appendicular skeleton increase. An understanding of the unique properties of CFR-PEEK devices and their impact on imaging is valuable to radiologists delivering care to orthopedic oncology patients in both the diagnostic and interventional settings. This multidisciplinary review aims to provide a comprehensive insight into the radiologic, surgical, and radiation oncology impact of these innovative devices.


Subject(s)
Spinal Neoplasms , Humans , Carbon Fiber/chemistry , Spinal Neoplasms/surgery , Polymers , Benzophenones , Polyethylene Glycols/chemistry , Ketones/chemistry , Carbon/chemistry
10.
Rev. venez. cir. ortop. traumatol ; 54(2): 53-61, dic. 2022. ilus
Article in Spanish | LILACS, LIVECS | ID: biblio-1516086

ABSTRACT

La Impresión 3D es una tecnología emergente utilizada cada vez más en medicina. En los países en vías de desarrollo, donde las fracturas por motocicletas y automóviles se encuentran en aumento, la disponibilidad de fijadores externos para el manejo de fracturas abiertas es un problema frecuente. La impresión 3D puede ser una alternativa económica e igualmente confiable a los dispositivos tradicionales elaborados con acero o titanio. El objetivo de este trabajo es mostrar la experiencia con el uso de Impresión 3D y su aplicación en el manejo clínico de fracturas abiertas diafisiarias de tibia. Se realizó un estudio pre-experimental y prospectivo. Se incluyeron 14 pacientes con fracturas de tibia AO/ASIF 42A, 42B y 42C tratados con un fijador externo con rótulas elaboradas con Impresión 3D como medida de Control de Daños en Ortopedia desde su ingreso hasta su resolución definitiva. Todos los pacientes fueron de sexo masculino, con un promedio de edad 23,16 años con 50% entre 20-23 años. Las fracturas fueron 42,85% tipo 42A, 37,71% 42B y 21,42% 42C. El 78,57% de las fracturas fueron ocasionadas por motocicletas: 57,14% grado II según Gustilo y Anderson, un 28,57% grado III y 14,28% grado I. El 37,71% eran politraumatizados. Ninguno de los pacientes presentó complicaciones como pérdida de la reducción, aflojamiento de las rótulas, ruptura o fatiga de las rótulas ni fatiga de la barra. La impresión 3D demostró ser una herramienta y alternativa útil en el manejo agudo de fracturas abiertas diafisiarias de tibia(AU)


3D Printing is an emerging technology used more and more in medicine. In developing countries, where motorcycle and automobile fractures are on the rise, the availability of external fixators for the management of open fractures is a frequent problem. 3D printing can be a cheap and equally reliable alternative to traditional devices made of steel or titanium. The objective of this work is to show the experience with the use of 3D Printing and its application in the clinical management of open diaphyseal fractures of the tibia. A pre-experimental and prospective study was made. 14 patients with AO/ASIF tibia fractures 42A, 42B and 42C treated with an external fixator with 3D-printed ball-caps as a Damage Control measure in Orthopedics from admission to final resolution were included. All patients were male, with an average age of 23,16 years, 50% between 20-23 years. The fractures were 42,85% type 42A, 37,71% 42B and 21,42% 42C. 78,57% of the fractures were caused by motorcycles: 57,14% grade II according to Gustilo and Anderson, 28,57% grade III and 14.28% grade I. 37,71% were polytraumatized. None of the patients had complications such as loss of reduction, loosening of the patellas, rupture or fatigue of the patellas, or rod fatigue. 3D printing proved to be a useful tool and alternative in the acute management of open diaphyseal fractures of the tibia(AU)


Subject(s)
Humans , Male , Female , Adolescent , Fractures, Open , Accidents, Traffic , Medical Records , Data Collection
11.
J Ayub Med Coll Abbottabad ; 34(Suppl 1)(3): S608-S612, 2022.
Article in English | MEDLINE | ID: mdl-36414577

ABSTRACT

Background: : A host of different methodologies have been implemented in the management of distal humerus fractures, including conservative measures and surgical fixation with a variety of plates. This study was conducted to evaluate the functional outcome of open reduction and internal fixation of extra articular distal humerus fractures with distal humerus locking compression plate. Methods: This is a retrospective cohort study of patients with close extra articular distal humerus fractures who underwent open reduction and internal fixation with a distal humerus locking compression plate at Ghurki Trust Teaching Hospital from July 2017 to December 2019. Various demographic indicators were used for data analysis and radiological union was assessed in serial follow-ups. Functional outcome was evaluated using the Mayo Performance Elbow Score at the final follow-up. Results: Thirty-one patients presented with extra-articular fracture of humerus (N=31) with average age 33.5±9.90 years. The average follow-up period was 13.8 months. Radiological union was achieved in 14.8 weeks (range 12-20 weeks). Out of 31 patients, 28 had excellent results with mean Mayo Elbow Performance Score of 94.8. Two patients (6.5%) had radial nerve palsy post-operatively. Conclusion: This study shows that open reduction and internal fixation of extra-articular distal humerus fractures with distal humerus locking compression plates allows for stable fixation, good functional outcome, and low complication rates.


Subject(s)
Humeral Fractures , Humans , Young Adult , Adult , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Retrospective Studies , Treatment Outcome , Humerus , Fracture Fixation, Internal/methods
12.
Clin Shoulder Elb ; 25(3): 230-235, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35971602

ABSTRACT

BACKGROUND: Unstable distal clavicles experience high non-union rates, prompting surgeons to recommend surgery for more predictable outcomes. There is a lack of consensus on the optimal method of surgical fixation, with an array of techniques described in the literature. We describe an alternative method of fixation involving the use of a distal clavicular anatomical locking plate with Fibertape cerclage augmentation in our series of patients. METHODS: Nine patients (8 males and 1 female), with a mean age of 36 years, who sustained unstable fracture of the distal clavicle in our institution were treated with our described technique. Postoperative range of motion, functional and pain scores, and time to radiographic union were measured over a mean follow-up period of 10 months. Incidences of postoperative complications were also recorded. RESULTS: At the last patient consult, the mean visual analog scale score was 0.88±0.35, with a mean Disabilities of the Arm, Shoulder, and Hand (DASH) score of 1.46±0.87 and American Shoulder and Elbow Surgeons (ASES) score of 94.1±3.57. The mean range of motion achieved was forward flexion at 173°±10.6°, abduction at 173°±10.6°, and external rotation at 74.4°±10.5°. All patients achieved internal rotation at a vertebral height of at least L2 with radiographical union at a mean of 10 weeks. No removal of implants was required. CONCLUSIONS: Our described technique of augmented fixation of the distal clavicle is effective, produces good clinical outcomes, and has minimal complications.

13.
Polymers (Basel) ; 14(14)2022 Jul 07.
Article in English | MEDLINE | ID: mdl-35890557

ABSTRACT

Osteosynthesis systems are used to fixate bone segments in maxillofacial surgery. Titanium osteosynthesis systems are currently the gold standard. However, the disadvantages result in symptomatic removal in up to 40% of cases. Biodegradable osteosynthesis systems, composed of degradable polymers, could reduce the need for removal of osteosynthesis systems while avoiding the aforementioned disadvantages of titanium osteosyntheses. However, disadvantages of biodegradable systems include decreased mechanical properties and possible foreign body reactions. In this review, the literature that focused on the in vitro and in vivo performances of biodegradable and titanium osteosyntheses is discussed. The focus was on factors underlying the favorable clinical outcome of osteosyntheses, including the degradation characteristics of biodegradable osteosyntheses and the host response they elicit. Furthermore, recommendations for clinical usage and future research are given. Based on the available (clinical) evidence, biodegradable copolymeric osteosyntheses are a viable alternative to titanium osteosyntheses when applied to treat maxillofacial trauma, with similar efficacy and significantly lower symptomatic osteosynthesis removal. For orthognathic surgery, biodegradable copolymeric osteosyntheses are a valid alternative to titanium osteosyntheses, but a longer operation time is needed. An osteosynthesis system composed of an amorphous copolymer, preferably using ultrasound welding with well-contoured shapes and sufficient mechanical properties, has the greatest potential as a biocompatible biodegradable copolymeric osteosynthesis system. Future research should focus on surface modifications (e.g., nanogel coatings) and novel biodegradable materials (e.g., magnesium alloys and silk) to address the disadvantages of current osteosynthesis systems.

14.
Chinese Journal of Orthopaedics ; (12): 1077-1083, 2022.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-957101

ABSTRACT

Objective:Comparison of four methods in intraoperative abduction angles (AA) measurements of human cast immobilization in developmental dysplasia of the hip (DDH) by visual inspection and electronic software according to different body surface markers.Methods:Data were retrospectively collected from January 2019 to November 2021 in a total of 27 patients (54 hips) who underwent closed or simple open reduction. There were 6 males and 21 females with an average age of 13.2 months. Five doctors used visual inspection and mobile phone software to measure the AA of the hip joint immediately during the operation, and compared with the postoperative MRI measurement results (AA-MRI). The four methods of intraoperative measurement were: Junior visualization (AA-JV), the intersection angle between the line connecting the center of the popliteal fossa and the contact center of the plaster frame and the line connecting the two ischial tuberosities; the same methods as method one by Senior visualization (AA-SV); the intersection angle between the line connecting the center of the popliteal fossa and the center of the anus and the line connecting the ischial tubercle (anus-popliteal, AA-AP); the intersection of the vertical line between the center of the popliteal fossa and the groin and the horizontal line of the center of the anus and the vertical line connecting the two ischial tuberosities intersect (anus-groin crease-popliteal, AA-AGCP). The t-test, correlation coefficient, linear regression and Bland-Altman test were used to evaluate the measurements. Results:Comparing the four intraoperative and postoperative AA-MRI measurement methods, AA-JV (42.69°±4.13°) < AA-SV (44.80°±4.08°) < AA-AGCP (46.25°±5.15°) < AA-MRI (47.68°±4.21°) < AA-AP (51.77°±5.30°), and the difference between AA-JV and AA-SV, AA-AP and AA-AGCP was statistically significant ( t=2.53, P=0.013; t=5.47, P=0.001), there was no significant difference between AA-AGCP and AA-MRI ( t=1.57, P=0.118). The inter-group agreement of the five methods ICC test ranged from 0.807 to 0.892, and the intra-group average agreement of AA-MRI was 0.948. All ICC results were greater than 0.75 with good agreement. Linear regression results showed that the four intraoperative measurement methods had a good or moderate linear relationship with AA-MRI, AA-AGCP ( R 2=0.499)>AA-AP ( R 2=0.318)>AA-SV ( R 2=0.253)>AA-JV ( R 2=0.217), AA-AGCP was the best measurement method. The results of Bland-Altman scatterplot of AA-AGCP and AA-MRI were in good agreement, the mean and standard deviation of bias were -0.796±3.247, and the limit of agreement was 95% LoA (-7.16, -5.57). Conclusion:The AA method of visualization before Spica casting was smaller than truth. The method AA-AGCP objectively by landmarks was the advocated means measuring abduction angle during operation with highly consistency, agreement and easily performed.

15.
Clin Anat ; 35(4): 454-460, 2022 May.
Article in English | MEDLINE | ID: mdl-34837269

ABSTRACT

Posterior fixations with lateral mass screws have become popular. The Roy-Camille and the Magerl techniques have been established and screw length was identified as a particularly important element. Sex and ethnicity are significant factors in cervical spine morphology, but few studies have been performed for screw length. We performed measurements using computed tomography (CT) images of adult patients hospitalized for surgery of the cervical spine, with targeted 3D data analysis. The final number of patients was 47 (33 men, 14 women) and 235 vertebrae. With the Roy-Camille technique, the screw length was longest at C3 (men: 13.0 mm ± 1.9 mm, women: 13.0 mm ± 1.9 mm) and smallest at C7 (men: 10.8 mm ± 1.8 mm, women: 9.4 mm ± 1.2 mm). With the Magerl technique, the screw length was smallest at C3 (men: 14.8 mm ± 1.6 mm, women: 14.3 mm ± 1.6 mm) and longest at C7 for men (16.8 mm ± 2.8 mm), and at C6 for women (15.4 mm ± 3.0 mm). To differ from spinal canal or pedicle, cervical lateral mass showed no obvious morphological differences from that of subjects of other ethnicity. The placement of a standard lateral mass screw would not cause complications in Japanese patients, even with the use of devices designed in North America or Europe. However, the anatomical background is essential because it is important to optimize the selection for each patient to avoid complications considering sex and individual differences.


Subject(s)
Bone Screws , Cervical Vertebrae , Adult , Cervical Vertebrae/anatomy & histology , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/surgery , Europe , Female , Humans , Male , Neck , Tomography, X-Ray Computed
16.
Eur J Oral Sci ; 129(5): e12800, 2021 10.
Article in English | MEDLINE | ID: mdl-34131965

ABSTRACT

Titanium osteosynthesis is currently the gold standard in orthognathic surgery. Use of biodegradable osteosyntheses avoids removal of plates/screws in a second operation. This systematic review aimed to assess the efficacy and morbidity of biodegradable vs. titanium osteosyntheses in orthognathic surgery (PROSPERO CRD42018086477). Patients with syndromic disorder(s) and/or cleft lip/palate were excluded. Randomised, prospective and retrospective controlled studies were searched for in nine databases (February 2021). The time periods perioperative, short-term, intermediate, long-term, and overall follow-up were studied. Meta-analyses were performed using random-effects models. A total of 9073 records was assessed, of which 33 were included, comprising 2551 patients. Seven RCTs had 'some concerns' while another seven RCTs had 'high' risk of bias (Cochrane-RoB2). No differences in malunion (qualitative analyses), mobility of bone segments [RR 1.37 (0.47; 3.99)], and malocclusion [RR 0.93 (0.39; 2.26)] were found. The operative time was longer in the biodegradable group [SMD 0.50 (0.09; 0.91)]. Symptomatic plate/screw removal was comparable among both groups [RR 1.29 (0.68; 2.44)]. Skeletal stability was similar in most types of surgery. Biodegradable osteosyntheses is a valid alternative to titanium osteosyntheses for orthognathic surgery, but with longer operation times. Since the quality of evidence varied from very low to moderate, high-quality research is necessary to elucidate the potential of biodegradable osteosyntheses.


Subject(s)
Cleft Lip , Cleft Palate , Orthognathic Surgery , Humans , Morbidity , Prospective Studies , Retrospective Studies , Titanium
17.
J Back Musculoskelet Rehabil ; 34(6): 957-964, 2021.
Article in English | MEDLINE | ID: mdl-34092597

ABSTRACT

OBJECTIVE: The aim of the study was to identify the efficacy of dynamic fixation using rigid tape (RT) in rehabilitation after surgery of terrible triad injury of the elbow (TTIE). METHODS: Sixty patients who underwent surgery of TTIE were equally randomly divided into RT group and hinged external fixation brace (HEFB) group. Dynamic fixations were applied for 8 weeks. General rehabilitation programs were performed for 3 months, 5 times a week. Follow-up (FU) was at six months. Main outcomes included pain (Visual Analogue Scale, VAS), muscle strength, range of motion (ROM), Elbow Function (Mayo Elbow Performance Index, MEPI), Quality of Life (QOL) (Short Form 36 Questionnaire, SF-36). RESULTS: There were significant time x group interactions for pain, ROM, MEPI, SF-36 (all p= 0.000), which demonstrated positive efficacy of both the two interventions. Difference at each time-point (except for baseline) of pain and ROM between the two groups was statistically significant (all p< 0.05). Some differences between the two groups were not statistically significant which at 14d on MEPI (p= 0.108) and at 21d (p= 0.259) and FU (p= 0.402) on QOL. Moreover, the increased muscle strength at each time-point had no statistically significant difference between the two groups (all p> 0.05). CONCLUSIONS: Both RT and HEFB could significantly improve the postoperative functional outcomes of the TTIE. However, early rehabilitation intervention could increase pain, which affected the corresponding function (MEPI) and QOL. Note that this kind of impact was short-term and reversible. The muscle strength and ROM were not affected by the increased severe pain, maintaining a trend of improvement. In addition, the subjects in the RT group improved faster and more efficiently and had better results with pain, ROM, MEPI, and QOL compared to the subjects in the HEFB group.


Subject(s)
Elbow Joint , Quality of Life , Elbow/surgery , Elbow Joint/surgery , Fracture Fixation , Humans , Range of Motion, Articular , Retrospective Studies , Treatment Outcome
18.
Rev. venez. cir. ortop. traumatol ; 53(1): 27-34, jun. 2021. tab
Article in Spanish | LIVECS, LILACS | ID: biblio-1252908

ABSTRACT

Las técnicas quirúrgicas mínimamente invasivas ayudan a que el proceso natural de la consolidación ósea ocurra proporcionando estabilidad biomecánica suficiente para obtener los mejores resultados. El objetivo de este trabajo es mostrar los resultados clínicos y radiológicos del tratamiento de las fracturas diafisiarias de tibia con osteosíntesis mínimamente invasiva con placa por cara lateral. Se realizó un estudio clínico observacional, prospectivo, longitudinal y no concurrente. Se incluyeron pacientes mayores de 18 años, de ambos sexos, con diagnósticos de fracturas diafisiarias de tibia 42A, 42B ó 42C, abiertas o cerradas. Se estableció tiempo de seguimiento mínimo de 6 meses. Se incluyeron 23 pacientes, 82,60% de sexo masculino. Promedio de edad de 21±5,63(16­49) años. La fractura más frecuente fue la 42B2 en 26,00% de los casos, y 34,80% fracturas fueron abiertas. A las 12 semanas, 65,10% habían alcanzado consolidación Montoya III; y para la semana 16, 91,30% de los pacientes. De acuerdo a la escala ASAMI, se alcanzaron resultados excelentes en 100,00% pacientes para la semana 16. No se presentaron complicaciones como infección, aflojamiento séptico o aséptico del implante, ni fatiga del mismo. El uso de la técnica MIPO para tratamiento de fracturas diafisiarias de la tibia, por cara lateral es una técnica efectiva y segura, con alta tasas de consolidación, mínimas complicaciones y buenos resultados finales(AU)


Minimally invasive surgical techniques help the natural bone healing process to occur, by providing enough biomechanical stability to obtain the best results. The objective is to show the clinical and radiological results of the treatment of diaphyseal tibial fractures with minimally invasive osteosynthesis with lateral plating. An observational, prospective, longitudinal and non-concurrent clinical study was made. Patients older than 18 years, both sexes, with diagnoses of open or closed tibial shaft fractures 42A, 42B or 42C, were included. A minimum follow-up time of 6 months was established. 23 patients were included, 82,60% male. Average age of 21 years. The most frequent fracture was 42B2 in 26,00% cases, and 34,80% were open fractures. At 12 weeks, 65,10% had reached Montoya III consolidation criterias; and for week 16, 91,30% of the patients. According to the ASAMI scale, excellent results were achieved in 100,00% patients. There were no complications such as infection, septic or aseptic loosening of the implant, or fatigue of the implant. The use of the MIPO technique for the treatment of diaphyseal fractures of the tibia on the lateral aspect is an effective and safe technique, with high rates of union, minimal complications and good final results(AU)


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Orthopedic Fixation Devices , Tibial Fractures/surgery , Bone Plates , Fracture Fixation, Internal , Tibial Fractures/classification , Prospective Studies , Minimally Invasive Surgical Procedures
19.
Arch. méd. Camaguey ; 25(2): e7003, mar.-abr. 2021. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1248833

ABSTRACT

RESUMEN Fundamento: las luxaciones puras del tobillo son lesiones muy infrecuentes, causadas por trauma de alta energía en especial los accidentes del tránsito y caídas de alturas. El tratamiento es por lo general quirúrgico. Objetivo: conocer una paciente con luxación traumática, pura y abierta de la articulación del tobillo. Presentación del caso: paciente de 50 años de edad, mestiza, femenina sin antecedentes mórbidos de salud, la cual sufrió caída de una altura aproximada de tres metros y es traída al cuerpo de guardia del Servicio de Ortopedia y Traumatología por presentar dolor e impotencia funcional total del tobillo derecho. Mediante la exploración física se detectó luxación abierta del tobillo derecho con franca exposición de las superficies articulares de la tibia distal y el astrágalo, además de tendones y partes blandas. Al tener en cuenta todos los elementos anteriores, se decidió llevar la paciente al quirófano, para tratamiento de tipo quirúrgico. De manera inmediata se realizó limpieza, irrigación pulsátil y desbridamiento de la herida en la articulación del tobillo, sutura de las partes blandas dañadas y se colocó fijación externa tipo Hoffman® en configuración de tipo triangular. Conclusiones: el tratamiento por general consiste en la reducción e inmovilización por seis semanas, sin embargo, en caso de afección severa de las partes blandas, donde se necesite la observación y cura de las heridas de forma sistemática, está justificado el uso de la fijación externa como lo es en el caso que se presentó.

20.
World J Clin Cases ; 9(8): 1814-1826, 2021 Mar 16.
Article in English | MEDLINE | ID: mdl-33748230

ABSTRACT

BACKGROUND: With the modernization of society and transportation in the last decades in China, the incidence of high-energy trauma increased sharply in China, including that of acetabular fractures. AIM: To establish different finite element models for acetabular posterior column fractures involving the quadrilateral area of the acetabulum. METHODS: The three-dimensional models of the normal and fractured pelvis and the five internal fixations were established using the computed tomography data of the pelvis of a living volunteer. After the vertebral body model was inserted in the way of origin matching and all cancellous bones were copied using the duplicated cancellous bone model as the subtractive entity, the Boolean operation was performed on the pelvis model to obtain the model of the complete pelvis cortical and cancellous bones. RESULTS: In the standing position, the maximum stress was 46.21 MPa. In the sitting position, the sacrum bore the simulated gravity load at the upper end. When comparing the five fixations, there were no significant differences in the stress mean values among groups (sitting: P = 0.9794; standing: P = 0.9741). In terms of displacement, the average displacement of the internal iliac plate group was smaller than that of the spring plate group (P = 0.002), and no differences were observed between the other pairs of groups (all P > 0.05). In the standing position, there were no significant differences in the mean value of displacement among the groups (P = 0.2985). It can be seen from the stress nephogram of the internal fixations in different positions that the stress of the internal fixation was mainly concentrated in the fracture segment. CONCLUSION: There were no significant differences among the fixations for acetabular posterior column fractures involving the quadrilateral area of the acetabulum.

SELECTION OF CITATIONS
SEARCH DETAIL