Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 390
Filter
1.
Artif Organs ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38957988

ABSTRACT

BACKGROUND: The Food and Drug Administration (FDA) blood pump is an open-source benchmark cardiovascular device introduced for validating computational and experimental performance analysis tools. The time-resolved velocity field for the whole impeller has not been established, as is undertaken in this particle image velocimetry (PIV) study. The level of instantaneous velocity fluctuations is important, to assess the flow-induced rotor vibrations which may contribute to the total blood damage. METHODS: To document these factors, time-resolved two-dimensional PIV experiments were performed that were precisely phase-locked with the impeller rotation angle. The velocity fields in the impeller and in the volute conformed with the previous single blade passage experiments of literature. RESULTS: Depending on the impeller orientation, present experiments showed that volute outlet nozzle flow can fluctuate up to 34% during impeller rotation, with a maximum standard experimental uncertainty of 2.2%. Likewise, the flow fields in each impeller passage also altered in average 33.5%. Considerably different vortex patterns were observed for different blade passages, with the largest vortical structures reaching an average core radii of 7 mm. The constant volute area employed in the FDA pump design contributes to the observed velocity imbalance, as illustrated in our velocity measurements. CONCLUSIONS: By introducing the impeller orientation parameter for the nozzle flow, this study considers the possible uncertainties influencing pump flow. Expanding the available literature data, analysis of inter-blade relative velocity fields is provided here for the first-time to the best of our knowledge. Consequently, our research fills a critical knowledge gap in the understanding of the flow dynamics of an important benchmark cardiovascular device. This study prompts the need for improved hydrodynamic designs and optimized devices to be used as benchmark test devices, to build more confidence and safety in future ventricular assist device performance assessment studies.

2.
ACS Appl Mater Interfaces ; 16(26): 34313-34325, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38907697

ABSTRACT

Boiling heat transfer has a high thermal efficiency by latent heat absorption, which makes it an attractive process for cooling electronic device chips. Critical heat flux (CHF), the maximum heat flux, is a crucial factor determining the operating range of the boiling applications. The CHF can be enhanced by improving the fluid supply to the boiling surface. Herein, micropillar interfacial surfaces have been proposed to increase the CHF by increasing the rewetting flow, which determines the fluid-supply capacity near the bubble contact line. A state-of-art two-phase particle image velocimetry (two-phase PIV) technique is introduced for rewetting flow measurement on micropillar structures (MPSs) to analyze the CHF-enhancement mechanism. The two-phase PIV visualization setup offers high spatial (∼120 µm) and temporal (∼2000 Hz) resolutions for measuring rewetting flow during bubble growth. The MPS samples exhibit enhanced CHF and rewetting flows compared to those on a plain surface. The roughest case, D04G10 sample, had a CHF of 164 W/cm2, 1.84 times higher than that of the plain surface. The D04G10 sample also recorded the highest rewetting velocity of 0.311 m/s, 4.7 times higher than that of the plain surface. The comparison between the rewetting flow and wicking performance shows that wicking-induced flow accounted for a substantial part (∼17%) of the rewetting flow and contributed significantly to the CHF enhancement owing to large rewetting flow by delaying vapor-film formation. Based on these findings, a new CHF model suggested by introducing the rewetting parameter shows a high CHF prediction accuracy of 94%.

3.
Front Neurol ; 15: 1364105, 2024.
Article in English | MEDLINE | ID: mdl-38831781

ABSTRACT

Background: Understanding the risk factors leading to intracranial aneurysm (IA) rupture have still not been fully clarified. They are vital for proper medical guidance of patients harboring unruptured IAs. Clarifying the hemodynamics associated with the point of rupture could help could provide useful information about some of the risk factors. Thus far, few studies have studied this issue with often diverging conclusions. Methods: We identified a point of rupture in patients operated for an IAs during surgery, using a combination of preoperative computed tomography (CT) and computed tomography angiography (CTA). Hemodynamic parameters were calculated both for the aneurysm sac as a whole and the point of rupture. In two cases, the results of CFD were compared with those of the experiment using particle image velocimetry (PIV). Results: We were able to identify 6 aneurysms with a well-demarcated point of rupture. In four aneurysms, the rupture point was near the vortex with low wall shear stress (WSS) and high oscillatory shear index (OSI). In one case, the rupture point was in the flow jet with high WSS. In the last case, the rupture point was in the significant bleb and no specific hemodynamic parameters were found. The CFD results were verified in the PIV part of the study. Conclusion: Our study shows that different hemodynamic scenarios are associated with the site of IA rupture. The numerical simulations were confirmed by laboratory models. This study further supports the hypothesis that various pathological pathways may lead to aneurysm wall damage resulting in its rupture.

4.
Fundam Res ; 4(2): 334-343, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38933520

ABSTRACT

By conducting a two-dimensional experimental study, this paper aims to enhance the understanding of the mechanism of sand convective motions in the vicinity of a wall subjected to long-term cyclic lateral loadings. The experimental tests were conducted in a rectangular sandbox with a transparent front-wall, through which the process of sand particle motions could be recorded by using a high-resolution digital camera. The images were processed with a high time-resolved PIV (Particle Image Velocimetry) system. Based on the experimental data, this work (1) presents the sand flow field in the convective zones; (2) provides means to describe the convection mechanism; (3) proposes the relationships between the loading conditions and dimensions of the region with intense sand movement; and (4) elaborates the similarity of the sand flow velocity structure within the sand convective zones.

5.
Front Med Technol ; 6: 1376649, 2024.
Article in English | MEDLINE | ID: mdl-38756328

ABSTRACT

This study aims to evaluate the fluid dynamic characteristics of the VenusP Valve System™ under varying cardiac outputs in vitro. A thorough hemodynamic study of the valve under physiological cardiac conditions was conducted and served as an independent assessment of the performance of the valve. Flow fields downstream of the valve near the pulmonary bifurcation were quantitatively studied by two-dimensional Particle Image Velocimetry (PIV). The obtained flow field was analyzed for potential regions of flow stasis and recirculation, and elevated shear stress and turbulence. High-speed en face imaging capturing the leaflet motion provided data for leaflet kinematic modeling. The experimental conditions for PIV studies were in accordance with ISO 5840-1:2021 standard, and two valves with different lengths and different orientations were studied. Results show good hemodynamics performance for the tested valves according to ISO 5840 standard without significant regions of flow stasis. Observed shear stress values are all well below established hemolysis limits.

6.
Int J Pharm ; 658: 124209, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38718973

ABSTRACT

The USP Rotating Basket Dissolution Testing Apparatus 1 is listed in the USP as one of the tools to assess dissolution of oral solid dosage forms. Baskets of different mesh sizes can be used to differentiate between dissolution profiles of different formulations. Here, we used Particle Image Velocimetry (PIV) to study the hydrodynamics of the USP Apparatus 1 using baskets with different mesh openings (10-, 20- and 40-mesh) revolving at 100 rpm, when the vessel was filled with 500 mL. The velocity profiles throughout the liquid were found to vary significantly using baskets of different mesh sizes, typically increasing with increased size of the opening of the basket mesh, especially for axial and radial velocities. This, in turn, resulted in a significantly different flow rate through the basket, which can be expected to significantly impact the dissolution rate of the drug product. A comparison between the results of this work with those of a previous study with a 900-mL fill volume (Sirasitthichoke et al., Intern. J. Pharmaceutics, 2021, 607: 120976), shows that although the hydrodynamics in the USP Apparatus 1 changed with fill level in the vessel, the flow rate through the basket was not significantly affected. This implies that tablets dissolving in the two systems would experience similar tablet-liquid medium mass transfer coefficients, and therefore similar initial dissolution rates, but different dissolution profiles because of the difference in volume.


Subject(s)
Drug Liberation , Hydrodynamics , Rheology , Solubility , Tablets , Rheology/methods , Drug Compounding/methods , Drug Compounding/instrumentation , Chemistry, Pharmaceutical/methods , Particle Size , Technology, Pharmaceutical/methods
7.
J Med Imaging (Bellingham) ; 11(3): 037001, 2024 May.
Article in English | MEDLINE | ID: mdl-38765874

ABSTRACT

Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV). Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow. In-plane velocity vectors were measured with oPIV and ePIV. Flow was simulated with CFD using boundary conditions from ePIV and additional duplex-ultrasound (DUS) measurements. Mean differences and 95%-limits of agreement (1.96*SD) of the velocity magnitudes in space and time were compared, and the similarity of vector complexity (VC) and time-averaged wall shear stress (TAWSS) was assessed. Results: Similar flow features were observed between modalities with velocities up to 110 and 330 cm/s in the control and the stenosed model, respectively. Relative to oPIV, ePIV and CFD-ePIV showed negligible mean differences in velocity (<3 cm/s), with limits of agreement of ±25 cm/s (control) and ±34 cm/s (stenosed). CFD-DUS overestimated velocities with limits of agreements of 13±40 and 16.1±55 cm/s for the control and stenosed model, respectively. VC showed good agreement, whereas TAWSS showed similar trends but with higher values for ePIV, CFD-DUS, and CFD-ePIV compared to oPIV. Conclusions: EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.

8.
bioRxiv ; 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38712212

ABSTRACT

A bilateral body plan is predominant throughout the animal kingdom. Bilaterality of amniote embryos becomes recognizable as midline morphogenesis begins at gastrulation, bisecting an embryonic field into the left and right sides. Soon after, left-right asymmetry also starts. While a series of laterality genes expressed after the left-right compartmentalization has been extensively studied, the laterality patterning prior to and during midline morphogenesis has remained unclear. Here, through a biophysical quantification in a high spatial and temporal resolution, applied to a chick model system, we show that a large-scale bilateral counter-rotating cell flow, termed as 'polonaise movements', display left-right asymmetries in early gastrulation. This cell movement starts prior to the formation of the primitive streak, which is the earliest midline structure, and earlier than expression of laterality genes. The cell flow speed and vorticity unravel the location and timing of the left-right asymmetries. The bilateral cell flow exhibited a Left side asymmetry at the beginning, but a transition towards Right dominance. Mitotic arrest that diminishes primitive streak formation resulted in changes in the bilateral flow pattern, but the Right dominance persisted. Our data indicate that the left-right asymmetry in amniote gastrula becomes detectable prior to the point when the asymmetric regulation of the laterality signals at the node leads to the left-right patterning. More broadly, our results suggest that physical processes can play an unexpected but significant role in influencing left-right laterality during embryonic development.

9.
JSES Int ; 8(3): 570-576, 2024 May.
Article in English | MEDLINE | ID: mdl-38707573

ABSTRACT

Background: The relationship between lower mobility, as measured by the elbow forward translation motion (T-motion) test, a new indicator of shoulder joint complex movement that measures elbow position when both dorsal hands are placed on the iliac crest while in a sitting position, and the parameters calculated by ultrasonography is unknown. The purpose of this study was to investigate the limiting factors of T-motion through motion analysis of the humeral head and rotator cuff muscles using ultrasonography in college baseball players. Methods: Thirteen college baseball players participated in this cross-sectional study. The shortest distance from the posterior edge of the glenoid to the humeral head was measured in the static and T-motion positions, and the difference was calculated as the humeral head translation. The velocity of the infraspinatus was calculated during shoulder internal/external rotation using the particle image velocimetry method. These parameters were compared between the throwing and nonthrowing sides to examine the limiting factors of T-motion. Results: This study indicated moderate-to-good reliability for the parameters calculated by ultrasonography. The mean anterior translation distance was significantly greater on the throwing side than on the nonthrowing side (r = 0.56, P = .015). The mean velocity of infraspinatus during internal rotation was significantly lower on the throwing side than on the nonthrowing side (r = 0.51, P = .028). Conclusion: Increased anterior translation of the humeral head and decreased the velocity of infraspinatus are likely correlated with reduced T-motion mobility in college baseball players. These methods showed potential for physical therapy assessment and intervention to prevent shoulder dysfunction.

10.
Lasers Med Sci ; 39(1): 112, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38656634

ABSTRACT

PURPOSE: To measure the dynamic characteristics of the flow field in a complex root canal model activated by two laser-activated irrigation (LAI) modalities at different activation energy outputs: photon-induced photoacoustic streaming (PIPS) and microshort pulse (MSP). METHODS: A phase-locked micro-scale Particle Image Velocimetry (µPIV) system was employed to characterise the temporal variations of LAI-induced velocity fields in the root canal following a single laser pulse. The wall shear stress (WSS) in the lateral root canal was subsequently estimated from the phase-averaged velocity fields. RESULTS: Both PIPS and MSP were able to generate the 'breath mode' of the irrigant current under all tested conditions. The transient irrigation flush in the root canal peaked at speeds close to 6 m/s. However, this intense flushing effect persisted for only about 2000 µs (or 3% of a single laser-pulse activation cycle). For MSP, the maximum WSS magnitude was approximately 3.08 Pa at an activation energy of E = 20 mJ/pulse, rising to 9.01 Pa at E = 50 mJ/pulse. In comparison, PIPS elevated the WSS to 10.63 Pa at E = 20 mJ/pulse. CONCLUSION: Elevating the activation energy can boost the peak flushing velocity and the maximum WSS, thereby enhancing irrigation efficiency. Given the same activation energy, PIPS outperforms MSP. Additionally, increasing the activation frequency may be an effective strategy to improve irrigation performance further.


Subject(s)
Rheology , Humans , Dental Pulp Cavity/radiation effects , Therapeutic Irrigation/methods , Therapeutic Irrigation/instrumentation , Lasers , Root Canal Irrigants , Photoacoustic Techniques/methods , Root Canal Preparation/methods , Root Canal Preparation/instrumentation
11.
Med Eng Phys ; 126: 104144, 2024 04.
Article in English | MEDLINE | ID: mdl-38621846

ABSTRACT

The present study adopts a smartphone-based approach for the experimental characterization of coronary flows. Technically, Particle Tracking Velocimetry (PTV) measurements were performed using a smartphone camera and a low-power continuous wave laser in realistic healthy and stenosed phantoms of left anterior descending artery with inflow Reynolds numbers approximately ranging from 20 to 200. A Lagrangian-Eulerian mapping was performed to convert Lagrangian PTV velocity data to a Eulerian grid. Eulerian velocity and vorticity data obtained from smartphone-based PTV measurements were compared with Particle Image Velocimetry (PIV) measurements performed with a smartphone-based setup and with a conventional setup based on a high-power double-pulsed laser and a CMOS camera. Smartphone-based PTV and PIV velocity flow fields substantially agreed with conventional PIV measurements, with the former characterized by lower average percentage differences than the latter. Discrepancies emerged at high flow regimes, especially at the stenosis throat, due to particle image blur generated by smartphone camera shutter speed and image acquisition frequency. In conclusion, the present findings demonstrate the feasibility of PTV measurements using a smartphone camera and a low-power light source for the in vitro characterization of cardiovascular flows for research, industrial and educational purposes, with advantages in terms of costs, safety and usability.


Subject(s)
Cardiovascular Physiological Phenomena , Smartphone , Rheology/methods , Blood Flow Velocity , Phantoms, Imaging
12.
Acta Biomater ; 181: 263-271, 2024 06.
Article in English | MEDLINE | ID: mdl-38677636

ABSTRACT

The remarkable damage-tolerance of enamel has been attributed to its hierarchical microstructure and the organized bands of decussated rods. A thorough characterization of the microscale rod evolution within the enamel is needed to elucidate this complex structure. While prior efforts in this area have made use of single particle tracking to track a single rod evolution to various degrees of success, such a process can be both computationally and labor intensive, limited to the evolution path of a single rod, and is therefore prone to error from potentially tracking outliers. Particle image velocimetry (PIV) is a well-established algorithm to derive field information from image sequences for processes that are time-dependent, such as fluid flows and structural deformation. In this work, we demonstrate the use of PIV in extracting the full-field microstructural distribution of rods within the enamel. Enamel samples from a wild African lion were analyzed using high-energy synchrotron X-ray micro-tomography. Results from the PIV analysis provide sufficient full-field information to reconstruct the growth of individual rods that can potentially enable rapid analysis of complex microstructures from high resolution synchrotron datasets. Such information can serve as a template for designing damage-tolerant bioinspired structures for advanced manufacturing. STATEMENT OF SIGNIFICANCE: Thorough characterization and analysis of biological microstructures (viz. dental enamel) allows us to understand the basis of their excellent mechanical properties. Prior efforts have successfully replicated these microstructures via single particle tracking, but the process is computationally and labor intensive. In this work, optical flow imaging algorithms were used to extract full-field microstructural distribution of enamel rods from synchrotron X-ray computed tomography datasets, and a field method was used to reconstruct the growth of individual rods. Such high throughput information allows for the rapid production/prototyping and advanced manufacturing of damage-tolerant bioinspired structures for specific engineering applications. Furthermore, the algorithms used herein are freely available and open source to broaden the availability of the proposed workflow to the general scientific community.


Subject(s)
Dental Enamel , Synchrotrons , Dental Enamel/chemistry , Dental Enamel/diagnostic imaging , Animals , X-Ray Microtomography , Rheology , Optical Imaging/methods
13.
Sci Rep ; 14(1): 5368, 2024 03 04.
Article in English | MEDLINE | ID: mdl-38438434

ABSTRACT

Ultrasonic irrigation during root canal treatment can enhance biofilm disruption. The challenge is to improve the fluid flow so that the irrigant reaches areas inaccessible to hand instrumentation. The aim of this study is to experimentally investigate how the flow field and hydrodynamic forces induced by ultrasonic irrigation are influenced by the ultrasound power and file insertion depth. A root canal phantom was 3D printed and used as a mold for the fabrication of a PDMS channel. An ultrasonic instrument with a #15K-file provided the irrigation. The flow field was studied by means of Particle Image Velocimetry (PIV). The time averaged velocity and shear stress distributions were found to vary significantly with ultrasound power. Their maximum values increase sharply for low powers and up to a critical power level. At and above this setting, the flow pattern changes, from the high velocity and shear stress region confined in the vicinity of the tip, to one covering the whole root canal domain. Exceeding this threshold also induces a moderate increase in the maximum velocities and shear stresses. The insertion depth was found to have a smaller effect on the measured velocity and shear stresses. Due to the oscillating nature of the flow, instantaneous maximum velocities and shear stresses can reach much higher values than the mean, especially for high powers. Ultrasonic irrigation will benefit from using a higher power setting as this does produce greater shear stresses near the walls of the root canal leading to the potential for increased biofilm removal.


Subject(s)
Dental Pulp Cavity , Ultrasonics , Ultrasonography , Phantoms, Imaging , Biofilms
14.
Clin Med Insights Cardiol ; 18: 11795468231221413, 2024.
Article in English | MEDLINE | ID: mdl-38449712

ABSTRACT

Supra-aortic extra-anatomic debranch (SAD) are prosthetic surgical grafts used to revascularize head and neck arteries that would be blocked during a surgical or hybrid procedure used in treating ascending and arch of the aorta pathologies. However, bypassing the supra-aortic arteries but not occluding their orifice might introduce potential for competitive flow that reduces bypass patency. Competitive flow within the bypasses across the supra-aortic arteries has not previously been identified. This research identified haemodynamics due to prophylactic inclusion of bypasses from the brachiocephalic artery (BCA) to the left common carotid artery (LCCA), and from the LCCA to left subclavian artery (LSA). Four model configurations investigated the risk of competitive flow and the necessity of intentionally blocking the proximal LSA and/or LCCA. Particle image velocimetry (PIV) was used to assess haemodynamics in each model configuration. We found potential for competitive flow in the BCA-LCCA bypass when the LSA was blocked, in the LSA-LCCA bypass, when the LCCA alone or LCCA and LSA were blocked. Flow stagnated at the start of systole within the RCCA-LCCA bypass, along with notable recirculation zones and reciprocating flow occurring throughout systolic flow. Flow also stagnated in the LCCA-LSA bypass when the LCCA was blocked. There was a large recirculation in the LCCA-LSA bypass when both the LCCA and LSA were blocked. The presence of competitive flow in all other configurations indicated that it is necessary to block or ligate the native LCCA and LSA once the debranch is made and the thoracic endovascular aortic repair (TEVAR) completed.

15.
Front Bioeng Biotechnol ; 12: 1367141, 2024.
Article in English | MEDLINE | ID: mdl-38532875

ABSTRACT

Induced pluripotent stem cell (iPSC)-derived cardiac organoids offer a versatile platform for personalized cardiac toxicity assessment, drug screening, disease modeling, and regenerative therapies. While previous image-based contractility analysis techniques allowed the assessment of contractility of two-dimensional cardiac models, they face limitations, including encountering high noise levels when applied to three-dimensional organoid models and requiring expensive equipment. Additionally, they offer fewer functional parameters compared to commercial software. To address these challenges, we developed an open-source, particle image velocimetry-based software (PIV-MyoMonitor) and demonstrated its capacity for accurate contractility analysis in both two- and three-dimensional cardiac models using standard lab equipment. Comparisons with four other open-source software programs highlighted the capability of PIV-MyoMonitor for more comprehensive quantitative analysis, providing 22 functional parameters and enhanced video outputs. We showcased its applicability in drug screening by characterizing the response of cardiac organoids to a known isotropic drug, isoprenaline. In sum, PIV-MyoMonitor enables reliable contractility assessment across various cardiac models without costly equipment or software. We believe this software will benefit a broader scientific community.

16.
J Biomech Eng ; 146(7)2024 07 01.
Article in English | MEDLINE | ID: mdl-38511303

ABSTRACT

Lowery urinary tract symptoms (LUTS) affect a large majority of the aging population. 3D Dynamic MRI shows promise as a noninvasive diagnostic tool that can assess bladder anatomy and function (urodynamics) while overcoming challenges associated with current urodynamic assessment methods. However, validation of this technique remains an unmet need. In this study, an anatomically realistic, bladder-mimicking in vitro flow model was created and used to systematically benchmark 3D dynamic MRI performance using a highly controllable syringe pump. Time-resolved volumes of the synthetic bladder model were obtained during simulated filling and voiding events and used to calculate volumetric flowrate. During MRI acquisitions, pressure during each event was recorded and used to create PV loops for work assessment. Error between control and MRI-derived volume for voiding and filling events exhibited 3.36% and 4.66% differences, respectively. A slight increase in average error was observed for MRI-derived flowrate when compared to the control flowrate (4.90% and 7.67% for voiding and filling, respectively). Overall, average error in segmented volumes increased with decreasing volume flowrate. Pressure drops were observed during voiding. Pressure increased during filling. Enhanced validation of novel 3D MRI urodynamics is achieved by using high-resolution PIV for visualizing and quantifying velocity inside the bladder model, which is not currently possible with 3D Dynamic MRI.


Subject(s)
Urinary Bladder , Urodynamics , Urinary Bladder/diagnostic imaging , Magnetic Resonance Imaging
17.
Ann Biomed Eng ; 52(5): 1378-1392, 2024 May.
Article in English | MEDLINE | ID: mdl-38407724

ABSTRACT

An in silico study is performed to investigate fluid dynamic effects of central venous catheter (CVC) placement within patient-specific cavo-atrial junctions. Prior studies show the CVC infusing a liquid, but this study focuses on the placement without any liquid emerging from the CVC. A 7 or 15-French double-lumen CVC is placed virtually in two patient-specific models; the CVC tip location is altered to understand its effect on the venous flow field. Results show that the CVC impact is trivial on flow in the superior vena cava when the catheter-to-vein ratio ranges from 0.15 to 0.33. Results further demonstrate that when the CVC tip is directly in the right atrium, flow vortices in the right atrium result in elevated wall shear stress near the tip hole. A recirculation region characterizes a spatially variable flow field inside the CVC side hole. Furthermore, flow stagnation is present near the internal side hole corners but an elevated wall shear stress near the curvature of the side hole's exit. These results suggest that optimal CVC tip location is within the superior vena cava, so as to lower the potential for platelet activation due to elevated shear stresses and that CVC geometry and location depth in the central vein significantly influences the local CVC fluid dynamics. A thrombosis model also shows thrombus formation at the side hole and tip hole. After modifying the catheter design, the hemodynamics change, which alter thrombus formation. Future studies are warranted to study CVC design and placement location in an effort to minimize CVC-induced thrombosis incidence.


Subject(s)
Central Venous Catheters , Thrombosis , Humans , Vena Cava, Superior , Heart Atria , Hemodynamics
18.
J Exp Biol ; 227(5)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38284759

ABSTRACT

Sessile barnacles feed by sweeping their basket-like cirral fan through the water, intercepting suspended prey. A primary component of the diet of adult barnacles is copepods that are sensitive to fluid disturbances and capable of escaping. How do barnacles manage to capture copepods despite the fluid disturbances they generate? We examined this question by describing the feeding current architecture of 1 cm sized Balanus crenatus using particle image velocimetry, and by studying the trajectories of captured copepods and the escapes of evading copepods. We found that barnacles produce a feeding current that arrives both from behind and the sides of the barnacle. The flow from the sides represents quiescent corridors of low fluid deformation and uninterrupted by the beating cirral fan. Potential prey arriving from behind are likely to encounter the cirral fan and, hence, capture here is highly unlikely. Accordingly, most captured copepods arrived through the quiet corridors, while most copepods arriving from behind managed to escape. Thus, it is the unique feeding flow architecture that allows feeding on evasive prey. We used the Landau-Squire jet as a simple model of the feeding current. For the Reynolds number of our experiments, the model reproduces the main features of the feeding current, including the lateral feeding corridors. Furthermore, the model suggests that smaller barnacle specimens, operating at lower Reynolds numbers, will produce a fore-aft symmetric feeding current without the lateral corridors. This suggests an ontogenetic diet shift from non-evasive prey to inclusion of evasive prey as the barnacle grows.


Subject(s)
Copepoda , Thoracica , Animals , Hydrodynamics , Rheology , Water
19.
Micromachines (Basel) ; 15(1)2024 Jan 04.
Article in English | MEDLINE | ID: mdl-38258219

ABSTRACT

This study emphasizes the potential risk posed by microplastics, particularly in tap water. Numerous studies have reported the removal of microplastics, but the limitations in addressing this issue remain challenging. To tackle this problem, a new method is introduced using tandem flexible structures (FSs) for microplastic removal. The present study focused on understanding the hydrodynamic characteristics between FSs to utilize microplastic removal. This comprehension of fluid flow and FSs offers valuable insights for improving the efficiency of microplastic removal methods. Therefore, the optimal conditions for removing microplastics were experimentally investigated inside the FSs gap region. Based on the gap distance and height, the flow structures between FSs were investigated. A small secondary vortex structure that could trap particles from upstream was continuously maintained behind the upstream FSs under certain geometric conditions. It is shown that this vortex structure has an effective way of confining the particles from upstream. The persistency of a small secondary vortex was also evaluated. This study may be helpful to researchers working on microplastic removal and FSs with a tandem arrangement.

20.
R Soc Open Sci ; 11(1): 231265, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38179082

ABSTRACT

During swimming, many fishes use pectoral fins for propulsion and, in the process, move substantial amounts of water rearward. However, the effect that this upstream wake has on the caudal fin remains largely unexplored. By coordinating motions of the caudal fin with the pectoral fins, fishes have the potential to create constructive flow interactions which may act to partially recapture the upstream energy lost in the pectoral fin wake. Using experimentally derived velocity and pressure fields for the silver mojarra (Eucinostomus argenteus), we show that pectoral-caudal fin (PCF) coordination enables the circulation and interception of pectoral fin wake vortices by the caudal fin. This acts to transfer energy to the caudal fin and enhance its hydrodynamic efficiency at swimming speeds where this behaviour occurs. We also find that mojarras commonly use PCF coordination in nature. The results offer new insights into the evolutionary drivers and behavioural plasticity of fish swimming as well as for developing more capable bioinspired underwater vehicles.

SELECTION OF CITATIONS
SEARCH DETAIL
...