Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 60(1): 53-58, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-710319

ABSTRACT

Objective The aim of this cross-sectional study was to evaluate the prevalence of low bone mass density in cystic fibrosis patients as well as to evaluate the factors associated with bone mass in such patients. Methods Bone mass density was measured by dual-photon X-ray absorptiometry of lumbar spine (L1-L4), in patients ≤19 years old, or lumbar spine and femur (total and neck) in patients ≥20 years old. Evaluations of nutritional status, biochemical parameters, and lung function were performed. Medication data were obtained from medical records. Results Fifty-eight patients were included in the study (25 males/ 33 females), mean age 23.9 years (16-53years). The prevalence of bone mass below the expected range for age at any site was 20.7%. None of the subjects had history of fracture. Lumbar spine Z-score in cystic fibrosis patients correlated positively with body mass index (r= 0.3, p=0.001), and forced expiratory volume in the first second (% predicted) (r=0.415, p=0.022). Mean lumbar spine Z-score was higher in women (p=0.001), in patients with no pancreatic insufficiency (p=0.032), and in patients with no hospitalization in the last 3 months (p=0.02). After multivariate analysis, body mass index (p= 0.001) and sex (p=0.001) were independently associated with Z-score in lumbar spine. Conclusion Low bone mass is a frequent problem in patients with CF, being independently associated with body mass index, and male sex. .


Objetivo Determinar a prevalência de massa óssea baixa em pacientes adolescentes e adultos com fibrose cística e estudar os fatores potencialmente associados. Métodos Densidade mineral óssea foi determinada por absorciometria por dupla emissão de raios X na coluna lombar em pacientes ≤ 19 anos e na coluna e no fêmur em pacientes ≥ 20 anos. Avaliações nutricionais, bioquímicas e pulmonares foram realizadas. Dados referentes ao tratamento farmacológico foram coletados. Resultados 58 pacientes foram incluídos no estudo (25 homens/33 mulheres), média de idade de 23,9 anos (16-53). Massa óssea abaixo da esperada foi verificada em 20,7% dos pacientes. Não houve histórico de fratura. Z-score da coluna lombar associou-se positivamente com índice de massa corporal (r=0,3; p=0,022), volume expiratório forçado (% previsto) (r=0,415; p=0,001). A média do Z-score da coluna foi mais alta nas mulheres que nos homens (p=0,001), em pacientes que não possuíam insuficiência pancreática (p=0,02) e em pacientes que não haviam sido hospitalizados nos últimos três meses (p=0,032). Os fatores encontrados como preditores independentes de Z-score da coluna lombar foram sexo masculino (p=0,001) e índice de massa corporal (p=0,001). Conclusão Massa óssea baixa é frequente em pacientes com FC, estando associada independentemente com índice de massa corporal e sexo masculino. .


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Bone Density/physiology , Bone Diseases, Metabolic/epidemiology , Cystic Fibrosis/complications , Absorptiometry, Photon , Body Mass Index , Bone Diseases, Metabolic/etiology , Brazil/epidemiology , Cross-Sectional Studies , Exocrine Pancreatic Insufficiency/complications , Femur , Forced Expiratory Volume , Lumbar Vertebrae , Nutritional Status , Prevalence , Risk Factors , Sex Factors
2.
Rev. bras. ortop ; 44(3): 260-265, maio-jun. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-524576

ABSTRACT

Este estudo teve como objectivo o desenvolvimento uma metodologia de fabrico rápido de implantes ortopédicos, em simultaneidade com a intervenção cirúrgica, considerando duas potenciais aplicações na área ortopédica: o fabrico de implantes anatomicamente adaptados e o fabrico de implantes para substituição de perdas ósseas. A inovação do trabalho desenvolvido consiste na obtenção in situ da geometria do implante, através da impressão directa de um material elastomérico (polivinilsiloxano) que permite obter com grande exactidão a geometria pretendida. Após digitalização do modelo obtido em material elastomérico, o implante final é fabricado por maquinagem recorrendo a um sistema de CAD/CAM dedicado. O implante após esterilização, pode ser colocado no paciente. O conceito foi desenvolvido com recurso a tecnologias disponíveis comercialmente e de baixo custo. O mesmo foi testado sob a forma de uma artroplastia da anca realizada in vivo numa ovelha. O acréscimo de tempo de cirurgia foi de 80 minutos sendo 40 directamente resultantes do processo de fabrico do implante. O sistema desenvolvido revelou-se eficiente no alcance dos objectivos propostos, possibilitando o fabrico de um implante durante um período de tempo perfeitamente compatível com o tempo de cirurgia.


This study, aimed the development of a methodology for rapid manufacture of orthopedic implants simultaneously with the surgical intervention, considering two potential applications in the fields of orthopedics: the manufacture of anatomically adapted implants and implants for bone loss replacement. This work innovation consists on the capitation of the in situ geometry of the implant by direct capture of the shape using an elastomeric material (polyvinylsiloxane) which allows fine detail and great accuracy of the geometry. After scanning the elastomeric specimen, the implant is obtained by machining using a CNC milling machine programmed with a dedicated CAD/CAM system. After sterilization, the implant is able to be placed on the patient. The concept was developed using low cost technology and commercially available. The system has been tested in an in vivo hip arthroplasty performed on a sheep. The time increase of surgery was 80 minutes being 40 minutes the time of implant manufacturing. The system developed has been tested and the goals defined of the study achieved enabling the rapid manufacture of an implant in a time period compatible with the surgery time.


Subject(s)
Humans , Arthroplasty , Prostheses and Implants
SELECTION OF CITATIONS
SEARCH DETAIL
...