1.
Article in English | MEDLINE | ID: mdl-38970466

ABSTRACT

INTRODUCTION: Over the past two decades, transcatheter aortic valve replacement (TAVR) has expanded its application across all surgical risk levels, including low-risk patients, where, due to longer life expectancy, reducing common pitfalls of TAVR is essential. To address these needs, many technological advancements have been developed. Myval and the new generation Myval Octacor (Meril Life Sciences Pvt. Ltd) are novel balloon-expandable (BE) transcatheter heart valve (THV) systems designed for the treatment of severe aortic stenosis. AREAS COVERED: This review aims to illustrate the design features of these novel THVs and the main evidence from available studies. Furthermore, we provide evidence of these THVs' performance in challenging scenarios such as extra-large aortic annuli, bicuspid aortic valves, and valve-in-valve/valve-in-ring procedures. EXPERT OPINION: Myval and Myval Octacor have demonstrated comparable early safety and clinical efficacy to the leading contemporary THVs, exhibiting remarkably low rates of moderate to severe paravalvular leak (PVL) and permanent pacemaker implantation (PPI). The wide range of sizes offered by the Myval family may minimize the risk of under-/oversizing, potentially explaining the lower rates of the aforementioned phenomena. Moreover, the presence of both, internal skirt and external reinforced cuff, may also explain the low rate of moderate to severe PVL.

2.
Clin Case Rep ; 12(7): e9130, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38983876

ABSTRACT

Permanent pacemaker implantation is the main treatment of symptomatic bradyarrhythmia, which has been widely used. Lead implantation is a critical step. When the lead malfunctions and needs to be replaced, extraction or abandonment of the primary lead (in whole or in part) should be determined according to the situation.

3.
Am J Cardiol ; 224: 26-35, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38844197

ABSTRACT

New-generation transcatheter heart valves have significantly improved technical success and procedural safety of transcatheter aortic valve implantation (TAVI) procedures; however, the incidence of permanent pacemaker implantation (PPI) remains a concern. This study aimed to assess the role of anatomic annulus features in determining periprocedural conduction disturbances leading to new PPI after TAVI using the last-generation Edwards SAPIEN balloon-expandable valves. In the context of a prospective single-center registry, we integrated the clinical and procedural predictors of PPI with anatomic data derived from multislice computed tomography. A total of 210 consecutive patients treated with balloon-expandable Edwards transcatheter heart valve were included in the study from 2015 to 2023. Technical success was achieved in 197 procedures (93.8%), and 26 patients (12.4%) required new PPI at the 30-day follow-up (median time to implantation 3 days). At the univariable logistic regression analysis, preprocedural right bundle branch block (odds ratio [OR] 2.24, 95% confidence interval [CI] 1.01 to 4.97, p = 0.047), annulus eccentricity ≥0.25 (OR 5.43, 95% CI 2.21 to 13.36, p <0.001), calcium volume at annulus of the right coronary cusp >48 mm3 (OR 2.60, 95% CI 1.13 to 5.96, p = 0.024), and prosthesis implantation depth greater than membranous septum length (OR 2.17, 95% CI 1.10 to 4.28, p = 0.026) were associated with new PPI risk. In the multivariable analysis, preprocedural right bundle branch block (OR 2.81, 95% CI 1.01 to 7.85, p = 0.049), annulus eccentricity ≥0.25 (OR 4.14, 95% CI 1.85 to 9.27, p <0.001), and annulusright coronary cusp calcium >48 mm3 (OR 2.89, 95% CI 1.07 to 7.82, p = 0.037) were confirmed as independent predictors of new PPI. In conclusion, specific anatomic features of the aortic valve annulus might have an additive role in determining the occurrence of conduction disturbances in patients who underwent TAVI with balloon-expandable valves. This suggests the possibility to use multislice computed tomography to improve the prediction of post-TAVI new PPI risk.

4.
J Clin Med ; 13(11)2024 May 22.
Article in English | MEDLINE | ID: mdl-38892761

ABSTRACT

Background/Objectives: Despite procedural improvements, post-transcatheter aortic valve replacement (TAVR) conduction disorders remain high. Analyzing the data from a monocentric TAVR registry, this study aims to determine predictive factors for PPI (primary outcome), the indication for PPI, and long-term outcomes among these patients (secondary outcomes). Methods: Conducted at Clairval Hospital in Marseille, France, this retrospective study included all consecutive patients from June 2012 to June 2019. Clinical, electrocardiographic, echocardiographic, and procedural data were collected, with outcomes assessed annually. Logistic regression identified PPI predictors and survival analyses were performed. Results: Of the 1458 patients initially considered, 1157 patients were included. PPI was needed in 21.5% of patients, primarily for third-degree atrioventricular block (46.4%). Predictor factors for PPI included baseline right bundle branch block (ORadj 2.49, 95% CI 1.44 to 4.30; p = 0.001), longer baseline QRS duration (ORadj 1.01, 95% CI 1.00 to1.02, p = 0.002), and self-expandable valves (ORadj 1.82, 95% CI, 1.09 to 3.03; p = 0.021). Seven-year estimated mortality was higher in PPI (43.3%) vs. non-PPI patients (30.9%) (log rank p = 0.048). PPI was an independent predictive factor of death (ORadj 2.49, 95% CI 1.4 to 4.3; p = 0.002). Conclusions: This study reveals elevated rates of PPI post-TAVR associated with increased mortality. These results underscore the pressing necessity to refine our practices, delineate precise indications, and enhance the long-term prognosis for implanted patients.

6.
Article in English | MEDLINE | ID: mdl-38871537

ABSTRACT

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

7.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38866455

ABSTRACT

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac Pacing, Artificial , Heart Valve Prosthesis , Pacemaker, Artificial , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aged , Time Factors , Aged, 80 and over , Treatment Outcome , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , United States/epidemiology
8.
Cureus ; 16(4): e58166, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38741795

ABSTRACT

Atrioventricular (AV) block is a common cardiac conduction disorder that is frequently encountered in clinical practice; however, the association with rare systemic conditions such as transthyretin amyloidosis (ATTR) is heavily underdiagnosed. ATTR amyloidosis is a systemic disorder characterized by the deposition of abnormal transthyretin protein fibrosis in various organs including the heart and vasculature, resulting in progressive organ dysfunction. We present a rare case of high-grade AV block unveiling ATTR cardiac amyloidosis with unusual hemodynamics, specifically severe supine hypertension with severe orthostatic hypotension. These findings posed a diagnostic challenge, underscoring the importance of a comprehensive diagnostic approach and meticulous review of medical history. Following pacemaker placement and the diagnosis of ATTR cardiac amyloidosis, our patient was started on a Tafamidis regimen.

9.
Cureus ; 16(5): e60339, 2024 May.
Article in English | MEDLINE | ID: mdl-38751404

ABSTRACT

We present the case of an elderly female who presented to the emergency department with dizziness. She was found to have an acute chronic kidney injury complicated by a complete heart block (CHB). She received a transvenous pacemaker and was taken for hemodialysis (HD) with complete resolution of her heart block. The following day, she was noted to be symptomatic and bradycardic. A repeat electrocardiogram showed a recurrence of the CHB. She was taken again for HD which led to the resolution of her conduction abnormalities. Electrophysiology was consulted and she had a permanent pacemaker implanted prior to being discharged.

11.
J Cardiothorac Surg ; 19(1): 296, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778360

ABSTRACT

BACKGROUND: There is little literature on the use of temporary pacemakers in children with fulminant myocarditis. Therefore, we summarized the use of temporary cardiac pacemakers in children with fulminant myocarditis in our hospital. METHODS: The clinical data of children with fulminant myocarditis treated with temporary pacemakers in Wuhan Children's Hospital from January 2017 to May 2022 were retrospectively analyzed. RESULTS: A total of 6 children were enrolled in the study, including 4 boys and 2 girls, with a median age of 50 months and a median weight of 15 kg. The average time from admission to pacemaker placement was 2.75 ± 0.4 h. The electrocardiogram showed that all 6 children had third-degree atrioventricular block (III°AVB). The initial pacing voltage, the sensory sensitivity of the ventricle and the pacing frequency were set to 5-10 mV, 5 V and 100-120 bpm respectively. The sinus rhythm was recovered in 5 patients within 61 h (17-134) h, and the median time of using temporary pacemaker was 132 h (63-445) h. One of the children had persistent III°AVB after the temporary pacemaker. With parental consent, the child was fitted with a permanent pacemaker on the 12th day of his illness. CONCLUSIONS: When fulminant myocarditis leads to severe bradycardia or atrioventricular block in children, temporary pacemakers have the characteristics of high safety to improve the heart function.


Subject(s)
Atrioventricular Block , Myocarditis , Pacemaker, Artificial , Humans , Myocarditis/therapy , Myocarditis/physiopathology , Male , Female , Child, Preschool , Retrospective Studies , Child , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Infant , Electrocardiography , Cardiac Pacing, Artificial/methods , Bradycardia/therapy , Bradycardia/physiopathology , Treatment Outcome
12.
World J Cardiol ; 16(4): 168-172, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38690219

ABSTRACT

Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk. Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings. However, procedural characteristics have at least as much impact on the final need for a permanent pacemaker and potentially on the pacing rate. In this regard, long-term follow-up and understanding of the impact of long-term stimulation is of utmost importance.

14.
J Innov Card Rhythm Manag ; 15(4): 5829-5837, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38715549

ABSTRACT

Permanent right ventricular apical pacing deteriorates cardiac systolic function in some patients. We investigated an alternative site for permanent pacemaker (PPM) lead positioning with the goal of achieving more physiological pacing. A total of 132 patients with bradyarrhythmias underwent PPM implantation at the right ventricular outflow tract (RVOT) with conventional active-fixation leads. A real-time cross-correlation analysis (CCA) was performed using the Synchromax® software (EXO Health, Seattle, WA, USA) to determine the optimal site for ventricular lead implantation based on the cardiac synchrony index. The follow-up period ranged from 6-36 months, and the following parameters were assessed: pacing capture threshold, lead stability, and the need for lead repositioning. Adequate parameters were achieved in 129 patients (98%), and there were no procedure-related complications. At follow-up, no leads were dislodged, pacing thresholds remained stable, and no lead required repositioning. Using real-time CCA as an intraoperative parameter during PPM implantation at the septal RVOT helps to achieve cardiac synchrony in the vast majority of cases. This technique is a simple, effective, and safe way to simplify and standardize PPM implantation at the RVOT.

15.
Article in English | MEDLINE | ID: mdl-38657782

ABSTRACT

OBJECTIVES: The long-term impact of permanent pacemaker (PPM) implantation on survival after cardiac surgery remains ill defined. We aimed to investigate the effect of PPM on survival and explore factors driving outcomes using meta-regression according to the type of surgery. METHODS: MEDLINE, EMBASE, and the Cochrane Library Central Register of Controlled Trials were searched through October 2023 to identify studies reporting the long-term outcomes of PPM implantation. The primary outcome was all-cause mortality during follow-up. The secondary outcome was heart failure rehospitalization. The subgroup analysis and meta-regression analysis were performed according to the type of surgery. RESULTS: A total of 28 studies met the inclusion criteria. 183,555 patients (n = 6298; PPM, n = 177,257; no PPM) were analyzed for all-cause mortality, with a weighted median follow-up of 79.7 months. PPM implantation was associated with increased risks of all-cause mortality during follow-up (hazard ratio, 1.22; confidence interval, 1.08-1.38, P < .01) and heart failure rehospitalization (hazard ratio, 1.24; confidence interval, 1.01-1.52, P = .04). Meta-regression demonstrated the adverse impact of PPM was less prominent in patients undergoing mitral or tricuspid valve surgery, whereas studies with a greater proportion with aortic valve replacement were associated with worse outcomes. Similarly, a greater proportion with atrioventricular block as an indication of PPM was associated with worse survival. CONCLUSIONS: PPM implantation after cardiac surgery is associated with a greater risk of long-term all-cause mortality and heart failure rehospitalization. This impact is more prominent in patients undergoing aortic valve surgery or atrioventricular block as an indication than those undergoing mitral or tricuspid valve surgery.

16.
J Cardiol ; 2024 Apr 06.
Article in English | MEDLINE | ID: mdl-38583663

ABSTRACT

BACKGROUND: With the widespread use of permanent pacemakers (PPM), and increased mortality associated with pacemaker endocarditis, it is essential to evaluate comorbidities that could potentially increase the risk of infective endocarditis (IE). Heart failure (HF), a common comorbidity, has not been well studied as an independent risk factor for development of IE in individuals with PPM. METHODS: The US National Inpatient Sample database was used to sample individuals with PPM. Patients with concomitant implantable cardioverter defibrillator, acute heart failure, history of endocarditis, intravenous drug use, prosthetic heart valves, or central venous catheter infection were excluded. Propensity matching was performed to match patients with and without HF. Pre- and post-match logistic regression was performed to assess HF as an independent risk factor for IE. A subgroup analysis was performed comparing IE rates between patients with HF with reduced (HFrEF) vs preserved (HFpEF) ejection fraction. RESULTS: Out of 333,571 patients with PPM included in the study, 121,862 (37 %) had HF. HF patients were older and had a higher prevalence of females. All comorbidities except for dental disease and cancer were more prevalent in the HF group. Patients with HF were 1.30 times more likely to develop IE [OR: 1.30 (1.16-1.47); p < 0.001]. The two cohorts were then matched for age, gender, and 20 comorbidities using a 1:1 propensity score matching algorithm. After matching, HF was still independently associated with increased risk of IE [OR: 1.62 (1.36-1.93); p < 0.001]. In our sub-group analysis, HFrEF and HFpEF patients had similar IE rates. CONCLUSION: In PPM population, HF was associated with an increased risk of IE compared to those without HF. We hypothesize that HF being a low-flow and high-inflammatory state might have contributed to this increased risk. Larger studies are required to corroborate our findings and evaluate the need for antimicrobial prophylaxis for this population.

18.
J Am Heart Assoc ; 13(9): e032777, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38639357

ABSTRACT

BACKGROUND: A delayed and recurrent complete atrioventricular block (CAVB) is a life-threatening complication of transcatheter aortic valve replacement (TAVR). Post-TAVR evaluation may be important in predicting delayed and recurrent CAVB requiring permanent pacemaker implantation (PPI). The impact of new-onset right bundle-branch block (RBBB) after TAVR on PPI remains unknown. METHODS AND RESULTS: In total, 407 patients with aortic stenosis who underwent TAVR were included in this analysis. Intraprocedural CAVB was defined as CAVB that occurred during TAVR. A 12-lead ECG was evaluated at baseline, immediately after TAVR, on postoperative days 1 and 5, and according to the need to identify new-onset bundle-branch block (BBB) and CAVB after TAVR. Forty patients (9.8%) required PPI, 17 patients (4.2%) had persistent intraprocedural CAVB, and 23 (5.7%) had delayed or recurrent CAVB after TAVR. The rates of no new-onset BBB, new-onset left BBB, and new-onset RBBB were 65.1%, 26.8%, and 4.7%, respectively. Compared with patients without new-onset BBB and those with new-onset left BBB, the rate of PPI was higher in patients with new-onset RBBB (3.4% versus 5.6% versus 44.4%, P<0.0001). On post-TAVR evaluation in patients without persistent intraprocedural CAVB, the multivariate logistic regression analysis showed that new-onset RBBB was a statistically significant predictor of PPI compared with no new-onset BBB (odds ratio [OR], 18.0 [95% CI, 5.94-54.4]) in addition to the use of a self-expanding valve (OR, 2.97 [95% CI, 1.09-8.10]). CONCLUSIONS: Patients with new-onset RBBB after TAVR are at high risk for PPI.


Subject(s)
Aortic Valve Stenosis , Bundle-Branch Block , Cardiac Pacing, Artificial , Electrocardiography , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , Bundle-Branch Block/physiopathology , Bundle-Branch Block/diagnosis , Aortic Valve Stenosis/surgery , Aged, 80 and over , Aged , Cardiac Pacing, Artificial/adverse effects , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Atrioventricular Block/diagnosis , Atrioventricular Block/physiopathology , Risk Factors , Retrospective Studies , Treatment Outcome , Time Factors , Postoperative Complications/etiology , Postoperative Complications/therapy , Postoperative Complications/diagnosis , Recurrence
20.
J Formos Med Assoc ; 2024 Mar 12.
Article in English | MEDLINE | ID: mdl-38480086

ABSTRACT

OBJECTIVE: The use of RDV in SAVR is associated with risk of conduction abnormality requiring PPM implantation, when compared to conventional bioprosthetic valves. We aimed to evaluate the outcome after selective placement of annular compression sutures during surgical aortic valve replacement (SAVR) using Intuity rapid deployment valve (RDV). METHODS: This is a retrospective study of prospectively enrolled patients receiving SAVR using Intuity RDV. Selective placement of commissural compression suture was assessed for all patients based on their annular morphology. Outcomes including operative mortality, rate of pacemaker rate, paravalvular leak and change in trans-valvular pressure gradient were analyzed. RESULTS: 56 consecutive patients underwent SAVR with the INTUITY RDV at our institution from January 2020 to November 2021. The Mean age of our cohort was 69.9 ± 10.6 years with a EuroSCORE II of 3.4 ± 2.4%. 28.6% (16/56) of patients had notable conduction abnormalities pre-operatively, which included atrial fibrillation and left/right bundle branch block. Compression sutures were selectively applied in 19/56 (33.9%) patients. Of which, 13 were bicuspid aortic valve. Post-operatively, we observed no conduction abnormality requiring PPM implantation. In addition, only 3 of the 56 (5.4%) had any degree of paravalvular leak on post-operative echocardiography (all ≤ mild). The mean reduction in trans-valvular gradient was 29.9 mmHg and the mean pressure gradient at 1 month and 1 year follow-up were 9.3 ± 3.6 mmHg and 10.2 ± 4.1 mmHg, respectively. CONCLUSIONS: Selective placement of compression suture helps to avoid unnecessary oversizing, which may reduce the risk of paravalvular leak and post-operative PPM implantation.