1.
Nucleus (La Habana) ; (57): 31-37, Jan.-June 2015.
Article in English | LILACS | ID: lil-754876

ABSTRACT

Simulation of a linear accelerator (linac) head requires determining the parameters that characterize the primary electron beam striking on the target which is a step that plays a vital role in the accuracy of Monte Carlo calculations. In this work, the commissioning of photon beams (6 MV and 15 MV) of an Elekta Precise accelerator, using the Monte Carlo code EGSnrc, was performed. The influence of the primary electron beam characteristics on the absorbed dose distribution for two photon qualities was studied. Using different combinations of mean energy and radial FWHM of the primary electron beam, deposited doses were calculated in a water phantom, for different field sizes. Based on the deposited dose in the phantom, depth dose curves and lateral dose profiles were constructed and compared with experimental values measured in an arrangement similar to the simulation. Taking into account the main differences between calculations and measurements, an acceptability criteria based on confidence limits was implemented. As expected, the lateral dose profiles for small field sizes were strongly infl uenced by the radial distribution (FWHM). The combinations of energy/FWHM that best reproduced the experimental results were used to generate the phase spaces, in order to obtain a model with the motorized wedge included and to calculate output factors. A good agreement was obtained between simulations and measurements for a wide range of fi eld sizes , being all the results found within the range of tolerance.


La simulación del cabezal de un acelerador lineal requiere de la determinación de los parámetros que caracterizan el haz primario de electrones que incide en el blanco de radiación, los cuales juegan un papel importante en la exactitud de los cálculos con Monte Carlo. En este trabajo se realizó la habilitación de los haces de fotones (6 MV y 15 MV) de un acelerador Elekta Precise, empleando el código de Monte Carlo EGSnrc. De forma adicional se estudió la influencia que ejerce cambios en las características del haz primario de electrones sobre la distribución de dosis absorbida en diferentes campos de radiación. Basado en la dosis absorbida, curvas de dosis en profundidad y perfiles de dosis se calcularon y compararon con valores experimentales medidos en un arreglo similar a las simulaciones empleando criterios de aceptabilidad. Los perfiles de dosis para campos pequeños resultaron ser fuertemente dependientes de la distribución radial (FWHM). Las combinaciones de energías/FWHM que mejor se ajustaron a las mediciones se emplearon en la generación de espacios de fases, para obtener un modelo con la cuña motorizada y para el cálculo de los factores de campo. Se obtuvo muy buena correspondencia entre las mediciones y las simulaciones realizadas, encontrándose todos los resultados dentro de los márgenes de tolerancias.

SELECTION OF CITATIONS
SEARCH DETAIL