Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Publication year range
1.
Materials (Basel) ; 13(8)2020 Apr 12.
Article in English | MEDLINE | ID: mdl-32290629

ABSTRACT

In this study, the use of Polyvinylchloride (PVC) and High Density Polystyrene (HDPS) was demonstrated as an alternative for the adsorption of Malathion. Adsorption kinetics and isotherms were used to compare three different adsorbent materials: PVC, HDPS, and activated carbon. The adsorption capacity of PVC was three times higher than activated carbon, and a theoretical value of 96.15 mg of Malathion could be adsorbed when using only 1 g of PVC. A pseudo first-order rate constant of 1.98 (1/h) was achieved according to Lagergren kinetic model. The adsorption rate and capacity values obtained in the present study are very promising since with very little adsorbent material it is possible to obtain high removal efficiencies. Phosphorous and sulfur elements were identified through Energy Dispersive X-ray (EDX) analysis and evidenced the malathion adsorption on PVC. The characteristic spectrum of malathion was identified by the Fourier Transform Infrared (FTIR) Spectroscopy analysis. The Thermogravimetric and Differential Thermal Analysis (TG/DTA) suggested that the adsorption of malathion on the surface of the polymers was mainly determined by hydrogen bonds.

2.
Ci. Rural ; 33(6)2003.
Article in Portuguese | VETINDEX | ID: vti-704272

ABSTRACT

In ten dogs with an average mean weight of 14,6 kg, the cervical vertebra 5 and 6 were destabilized and fixed with plates of 2mm of thickness. The purpose of this work was to verify the effect of orthopedic PVC plates on the internal stabilization of the caudal cervical spine of dogs by studying the occurrence of alterations in the bone tissue and fibrous tissue adjacent to the plate after 180 days of permanence of the material in the dogs' organism. PVC causes progressive bone alterations, which, in the long term, could promote the loosening of the screws and failure of the implant. It also induces the formation of foreign body granuloma and inflammatory reactions which could cause degradation of the implant. Thus, PVC plates do not satisfy the majority of properties required of a biomaterial, its use not being recommended in veterinary orthopedics.


Em 10 cães com peso médio de 14,6kg, as vértebras cervicais 5 e 6 foram cirurgicamente desestabilizadas através da secção do disco intervertebral e, em seguida, estabilizadas com placas ortopédicas confeccionadas com PVC de 2mm de espessura, para após 180 dias, proceder-se ao estudo histológico do tecido ósseo e conjuntivo circunvizinho. Constatou-se que o PVC causou alterações ósseas que podem ter favorecido o afrouxamento dos parafusos e a falha do implante. O material induziu ainda à formação de granuloma de corpo estranho e a reações inflamatórias locais que podem ter causado degradação do material implantado. Assim, placas de PVC, apesar de proporcionarem estabilidade e alinhamento da coluna vertebral, não satisfazem a maioria das propriedades necessárias a um biomaterial, não sendo recomendadaa a sua utilização em ortopedia veterinária.

3.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1476049

ABSTRACT

In ten dogs with an average mean weight of 14,6 kg, the cervical vertebra 5 and 6 were destabilized and fixed with plates of 2mm of thickness. The purpose of this work was to verify the effect of orthopedic PVC plates on the internal stabilization of the caudal cervical spine of dogs by studying the occurrence of alterations in the bone tissue and fibrous tissue adjacent to the plate after 180 days of permanence of the material in the dogs' organism. PVC causes progressive bone alterations, which, in the long term, could promote the loosening of the screws and failure of the implant. It also induces the formation of foreign body granuloma and inflammatory reactions which could cause degradation of the implant. Thus, PVC plates do not satisfy the majority of properties required of a biomaterial, its use not being recommended in veterinary orthopedics.


Em 10 cães com peso médio de 14,6kg, as vértebras cervicais 5 e 6 foram cirurgicamente desestabilizadas através da secção do disco intervertebral e, em seguida, estabilizadas com placas ortopédicas confeccionadas com PVC de 2mm de espessura, para após 180 dias, proceder-se ao estudo histológico do tecido ósseo e conjuntivo circunvizinho. Constatou-se que o PVC causou alterações ósseas que podem ter favorecido o afrouxamento dos parafusos e a falha do implante. O material induziu ainda à formação de granuloma de corpo estranho e a reações inflamatórias locais que podem ter causado degradação do material implantado. Assim, placas de PVC, apesar de proporcionarem estabilidade e alinhamento da coluna vertebral, não satisfazem a maioria das propriedades necessárias a um biomaterial, não sendo recomendadaa a sua utilização em ortopedia veterinária.

4.
Ciênc. rural ; Ciênc. rural (Online);27(1): 103-112, Jan.-Mar. 1997. ilus, tab
Article in Portuguese | LILACS | ID: lil-483508

ABSTRACT

Utilizando-se 20 cães, com o segmento lombar da coluna vertebral cirurgicamente desestabilizado na junção das vértebras L2-L3, foram estudadas a toxicidade e o aceite de placas ortopédicas de cloreto de polivinila (PVC) Tigre®, fixadas com parafusos nos corpos vertebrais e com fio ortopédico de aço inoxidável nos processos espinhosos. Apesar de que durante os 45 dias do estudo, verificaram-se resultados favoráveis quanto ao estado clínico-neurológico e resultados dos exames laboratoriais, e que os estudos microscópicos do fígado, rim e linfonodo poptileo não ofereceram indícios conclusivos de toxicidade, o material mostrou não ser inócuo já que desencadeia: (l) reação inflamatória granulomatosa e alterações vasculares no tecido fibroso circunvizinho à placa; (2) hematopoiese esplénica e (3) lesões vertebrais como osteonecrose, osteoporose, osteopenia, osteopetrose e mielofïbrose. Apesar das alterações serem subclínicas, estes dados sugerem que mais pesquisas devem ser realizadas à procura de PVCs menos lesivos, antes de se fazer a indicação deste material em traumatologia vertebral.


The tissue reaction and toxicity ofpolyvinylchloride (PVC) orthopedic plates, jixed by screws Io lhe vertebral bodies and by cerdage vires to lhe spinous processes, were tested in twenty dogs with lhe lumbar spine destabitized ai L2-L3. During the 45 days of the study, the technique was considered effective based on clinical results. Microscópio studiesjromfragments of the tiver, kidney and popliteat lymph node, did not suggest PVC plates toxicity, buí it were observed: l) granulomatous inflammatory reaction and vascular alterations in íhefibrous lissues adjacent to theplate; 2) splenic hematopoiesis and 3) vertebral osteonecrosis, osteoporosis, osteopetrosis, osteopenia and myelofibrosis. Although these alterations were found subclinics, more research should be done in order to found harmiess PVC, before introducing this material in spinal traumatology.

5.
Ci. Rural ; 27(1)1997.
Article in Portuguese | VETINDEX | ID: vti-703214

ABSTRACT

The tissue reaction and toxicity ofpolyvinylchloride (PVC) orthopedic plates, jixed by screws Io lhe vertebral bodies and by cerdage vires to lhe spinous processes, were tested in twenty dogs with lhe lumbar spine destabitized ai L2-L3. During the 45 days of the study, the technique was considered effective based on clinical results. Microscópio studiesjromfragments of the tiver, kidney and popliteat lymph node, did not suggest PVC plates toxicity, buí it were observed: l) granulomatous inflammatory reaction and vascular alterations in íhefibrous lissues adjacent to theplate; 2) splenic hematopoiesis and 3) vertebral osteonecrosis, osteoporosis, osteopetrosis, osteopenia and myelofibrosis. Although these alterations were found subclinics, more research should be done in order to found harmiess PVC, before introducing this material in spinal traumatology.


Utilizando-se 20 cães, com o segmento lombar da coluna vertebral cirurgicamente desestabilizado na junção das vértebras L2-L3, foram estudadas a toxicidade e o aceite de placas ortopédicas de cloreto de polivinila (PVC) Tigre®, fixadas com parafusos nos corpos vertebrais e com fio ortopédico de aço inoxidável nos processos espinhosos. Apesar de que durante os 45 dias do estudo, verificaram-se resultados favoráveis quanto ao estado clínico-neurológico e resultados dos exames laboratoriais, e que os estudos microscópicos do fígado, rim e linfonodo poptileo não ofereceram indícios conclusivos de toxicidade, o material mostrou não ser inócuo já que desencadeia: (l) reação inflamatória granulomatosa e alterações vasculares no tecido fibroso circunvizinho à placa; (2) hematopoiese esplénica e (3) lesões vertebrais como osteonecrose, osteoporose, osteopenia, osteopetrose e mielofïbrose. Apesar das alterações serem subclínicas, estes dados sugerem que mais pesquisas devem ser realizadas à procura de PVCs menos lesivos, antes de se fazer a indicação deste material em traumatologia vertebral.

6.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1474957

ABSTRACT

The tissue reaction and toxicity ofpolyvinylchloride (PVC) orthopedic plates, jixed by screws Io lhe vertebral bodies and by cerdage vires to lhe spinous processes, were tested in twenty dogs with lhe lumbar spine destabitized ai L2-L3. During the 45 days of the study, the technique was considered effective based on clinical results. Microscópio studiesjromfragments of the tiver, kidney and popliteat lymph node, did not suggest PVC plates toxicity, buí it were observed: l) granulomatous inflammatory reaction and vascular alterations in íhefibrous lissues adjacent to theplate; 2) splenic hematopoiesis and 3) vertebral osteonecrosis, osteoporosis, osteopetrosis, osteopenia and myelofibrosis. Although these alterations were found subclinics, more research should be done in order to found harmiess PVC, before introducing this material in spinal traumatology.


Utilizando-se 20 cães, com o segmento lombar da coluna vertebral cirurgicamente desestabilizado na junção das vértebras L2-L3, foram estudadas a toxicidade e o aceite de placas ortopédicas de cloreto de polivinila (PVC) Tigre®, fixadas com parafusos nos corpos vertebrais e com fio ortopédico de aço inoxidável nos processos espinhosos. Apesar de que durante os 45 dias do estudo, verificaram-se resultados favoráveis quanto ao estado clínico-neurológico e resultados dos exames laboratoriais, e que os estudos microscópicos do fígado, rim e linfonodo poptileo não ofereceram indícios conclusivos de toxicidade, o material mostrou não ser inócuo já que desencadeia: (l) reação inflamatória granulomatosa e alterações vasculares no tecido fibroso circunvizinho à placa; (2) hematopoiese esplénica e (3) lesões vertebrais como osteonecrose, osteoporose, osteopenia, osteopetrose e mielofïbrose. Apesar das alterações serem subclínicas, estes dados sugerem que mais pesquisas devem ser realizadas à procura de PVCs menos lesivos, antes de se fazer a indicação deste material em traumatologia vertebral.

SELECTION OF CITATIONS
SEARCH DETAIL