Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters











Database
Publication year range
1.
Arq. bras. oftalmol ; Arq. bras. oftalmol;86(6): e2021, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520197

ABSTRACT

ABSTRACT Purpose: To evaluate the visual acuity of healthy and amblyopic children using sweep visual evoked potential and compare the results with those of Snellen visual acuity testing. Methods: A total of 160 children aged 6-17 years were included in the study. Of these, 104 (65%) were aged 7-17 years old, able to verbally communicate, and did not have any systemic or ocular pathology (Group 1). Group 2 included 56 (35%) children aged 6-17 years, able to verbally communicate, and had strabismus or anisometropic amblyopia whose best corrected visual acuity was between 0.1 and 0.8. All subjects underwent a detailed ophthalmological examination and sweep visual evoked potential measurement. Demographic characteristics, ocular findings, best corrected visual acuity, and sweep visual evoked potential results were recorded. Results: In Group 1, the mean and maximum visual acuity values for sweep visual evoked potential were lower than the Snellen best corrected visual acuity (p<0.001, for both, respectively). Bland-Altman analysis revealed that in Group 1, the distribution of the differences between the Snellen best corrected visual acuity and mean sweep visual evoked potential visual acuity was ±0.11 logMAR, and the distribution of the differences between the Snellen best corrected visual acuity and maximum sweep visual evoked potential visual acuity was ±0.023 logMAR. In Group 2, the mean and maximum sweep visual evoked potential visual acuity were lower than the Snellen best corrected visual acuity (p<0.001 and p=0.009, respectively). Bland-Altman analysis revealed that the distribution of the differences between the Snellen best corrected visual acuity and mean sweep visual evoked potential visual acuity was ±0.16 logMAR, and the distribution of the differences between the Snellen best corrected visual acuity and maximum sweep visual evoked potential visual acuity was ±0.19 logMAR. Conclusions: Sweep visual evoked potential visual acuity measurements have comparable results with Snellen visual acuity measurements. This technique is an objective and reliable method for evaluating visual acuity in children.


RESUMO Objetivo: Avaliar a acuidade visual através de po­tenciais evocados visuais de varredura em crianças saudáveis e ambliópicas, comparando-a com a acuidade visual pelo teste de Snellen. Métodos: Foram incluídas no estudo 160 crianças com idades entre 6 e 17 anos. Desse total, 104 crianças (65%) estavam entre 7 e 17 anos de idade, eram capazes de comunicação verbal e não tinham nenhuma patologia ocular ou sistêmica (Grupo 1). O grupo 2 incluiu 56 crianças verbais (35%) com idades entre 6 e 17 anos e portadoras de estrabismo ou ambliopia anisometrópica, com a melhor acuidade visual corrigida entre 0,1 e 0,8. Todos os pacientes foram submetidos a um exame oftalmológico detalhado e a uma medição do potencial evocado visual por varredura. Registraram-se as características demográficas, os achados oculares, a melhor acuidade visual corrigida e os resultados do potencial evocado visual por varredura. Resultados: No Grupo 1, os valores médios e máximos da acuidade visual pelo potencial evocado visual por varredura mostraram-se menores que a melhor acuidade visual corrigida medida através do teste de Snellen (p<0,001 para ambas as medições). Uma análise de Bland-Altman revelou que no grupo 1, a distribuição das diferenças entre a melhor acuidade visual corrigida pelo teste de Snellen e a média do potencial evocado visual por varredura foi de ± 0,11 logMAR, enquanto a distribuição das diferenças entre a melhor acuidade visual corrigida pelo teste de Snellen e o valor máximo do potencial evocado visual por varredura foi de ± 0,023 logMAR. No Grupo 2, os valores médio e máximo do potencial evocado visual por varredura mostraram-se menores que a melhor acuidade visual corrigida pelo teste de Snellen (respectivamente, p<0,001 e p=0,009). A análise de Bland-Altman revelou que a distribuição das diferenças entre a melhor acuidade visual corrigida pelo teste de Snellen e a média do potencial evocado visual por varredura foi de ± 0,16 logMAR, enquanto a distribuição das diferenças entre a melhor acuidade visual corrigida pelo teste de Snellen e o valor máximo do potencial evocado visual por varredura foi de ± 0,19 logMAR. Conclusões: As medidas da acuidade visual através do potencial evocado visual por varredura mostram resultados comparáveis às medidas da acuidade visual pelo teste de Snellen. Essa técnica é um método objetivo e confiável de se avaliar a acuidade visual em crianças.

2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;84(2): 140-148, Mar,-Apr. 2021. tab, graf
Article in English | LILACS | ID: biblio-1153128

ABSTRACT

ABSTRACT Purpose: To determine visual impairment due to optic pathway tumors in children unable to perform recognition acuity tests. Methods: Grating visual acuity scores, in logMAR, were obtained by sweep visually evoked potentials (SVEP) in children with optic pathway tumors. The binocular grating visual acuity deficit was calculated by comparison with age-based norms and then assigned to categories of visual impairment as mild (from 0.10 to 0.39 logMAR), moderate (from 0.40 to 0.79 logMAR), or severe (≥0.80 logMAR). Interocular differences were calculated by subtraction and considered increased if >0.10 logMAR. Results: The participants were 25 children (13 boys; mean ± SD age, 35.1 ± 25.9 months; median age, 32.0 months) with optic pathway tumors (24 gliomas and 1 embryonal tumor), mostly located at the hypothalamic-chiasmatic transition (n=21; 84.0%) with visual abnormalities reported by parents (n=17; 68.0%). The mean grating acuity deficit was 0.60 ± 0.36 logMAR (median, 0.56 logMAR). Visual impairment was detected in all cases and was classified as mild in 10 (40.0%), moderate in 8 (32.0%), and severe in 7 (28.0%) children, along with increased interocular differences (>0.1 logMAR) (n=16; 64.0%). The remarkable ophthalmological abnormalities were nystagmus (n=17; 68.0%), optic disc cupping and/or pallor (n=13; 52.0%), strabismus (n=12; 48.0%), and poor visual behavior (n=9; 36.0%). Conclusion: In children with optic pathway tumors who were unable to perform recognition acuity tests, it was possible to quantify visual impairment by sweep-visually evoked potentials and to evaluate interocular differences in acuity. The severity of age-based grating visual acuity deficit and interocular differences was in accordance with ophthalmological abnormalities and neuroimaging results. Grating visual acuity deficit is useful for characterizing visual status in children with optic pathway tumors and for supporting neuro-oncologic management.(AU)


RESUMO Objetivo: Determinar o grau de deficiência visual em crianças com tumores da via óptica incapazes de informar a acuidade visual de reconhecimento. Método: A acuidade visual de grades, em logMAR, foi estimada por potenciais visuais evocados de varredura em crianças com tumores das vias ópticas. O déficit da acuidade visual de grades binocular foi calculado em relação ao valor mediano normativo esperado para a idade e a deficiência visual, classificada como leve (0,10 a 0,39 logMAR), moderada (0,40 a 0,79 logMAR) ou grave (≥0,80 logMAR). Diferenças inter-oculares foram calculadas por subtração e consideradas aumentadas se >0,10 logMAR. Resultados: Foram avaliadas 25 crianças (13 meninos; média de idade ± DP=35,1± 25,9 meses; mediana=32,0 meses) com tumores da via óptica (24 gliomas e 1 tumor embrionário) localizados particularmente na transição hipotalâmico-quiasmática (n=21; 84,0%) e com anormalidades visuais detectadas pelos pais (n=17; 68,0%). A média do déficit da acuidade de grades foi 0,60 ± 0,36 logMAR (mediana=0,56 logMAR). Observou-se deficiência visual leve em 10 (40,0%), moderada em 8 (32,0%) e grave em 7 (28,0%), além de aumento da diferença interocular da acuidade visual (n=16; 64,0%). As principais alterações oftalmológicas encontradas foram: nistagmo (n=17; 68,0%), aumento da escavação do disco óptico e/ou palidez (n=13; 52,0%), estrabismo (n=12; 48,0%) e comportamento visual pobre (n=9; 36,0%). Conclusão: Em crianças com tumor da via óptica e incapazes de responder aos testes de acuidade visual de reconhecimento, foi possível quantificar deficiência visual por meio dos potenciais visuais evocados de varredura e avaliar a diferença interocular da acuidade visual de grades. A gravidade do déficit da acuidade visual de grades relacionado à idade e a diferença interocular da acuidade visual de grades foram congruentes com alterações oftalmológicas e neuroimagem. O déficit da acuidade visual de grades foi útil à caracterização do estado visual em crianças com tumores da via óptica e ao embasamento da assistência neuro-oncológica.(AU)


Subject(s)
Humans , Child , Visual Pathways/pathology , Visual Acuity , Optic Nerve Glioma/pathology , Vision Disorders/etiology , Evoked Potentials, Visual
3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;79(5): 303-307, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-827963

ABSTRACT

ABSTRACT Purpose: To investigate the contributions of transient pattern-reversal visual evoked potentials in the diagnosis of ocular malingering at a Brazilian university hospital. Methods: Adult patients with suspected malingering in one or both eyes were referred for visual evoked potential testing. Data from patients' medical records were reviewed and analyzed retrospectively. Data analysis included the distance optotype visual acuity based on a ETDRS retro-illuminated chart and the transient pattern-reversal visual evoked potential parameters of latency (milliseconds) and amplitude (microvolts) for the P100 component, using checkerboards with visual subtenses of 15' and 60'. Motivations for malingering were noted. Results: The 20 subjects included 11 (55%) women. Patient ages ranged from 21 to 61 years (mean= 45.05 ± 11.76 years; median= 49 years). In 8 patients (6 women), both eyes exhibited reduced visual acuity with normal pattern-reversal visually evoked potential parameters (pure malingerers). The remaining 12 patients (7 men) exhibited reduced vision in only 1 eye, with simulated reduced vision in the contralateral eye (exaggerators). Financial motivation was noted in 18 patients (9 men). Conclusion: Normal pattern-reversal visually evoked potential parameters with suspected ocular malingering were observed in a 20 patient cohort. This electrophysiological technique appeared to be useful as a measure of visual pathway integrity in this specific population.


RESUMO Objetivo: Investigar a contribuição dos potenciais visuais evocados por padrões reversos no diagnóstico de simulação de baixa de visão em um hospital universitário do Brasil. Métodos: Um grupo de pacientes adultos com suspeita de simulação de baixa de visão em um ou ambos os olhos foi avaliado e os dados analisados retrospectivamente. Foram medidos: acuidade visual de optotipos informada para longe utilizando a tabela ETDRS, parâmetros dos potenciais visuais evocados por padrões reversos de latência (milissegundos) e amplitude (microvolts) para o componente P100 com estímulos de ângulos visuais de 15' e 60'. A motivação do paciente para a simulação foi anotada. Resultados: Os participantes foram 20 indivíduos com 11 (55%) do sexo feminino. A idade variou de 21 a 61 anos (média= 45,05 ± 11,76 anos; mediana= 49 anos). Em 8 pacientes (6 mulheres) ambos os olhos tinham acuidade visual reduzida com parâmetros dos potenciais visuais evocados por padrão reverso normais para ambos os olhos (simuladores puros). Uma subsérie separada de 12 pacientes (7 homens) tinha visão reduzida em apenas um olho e estavam simulando redução da visão no outro olho (exacerbadores). A motivação financeira foi observada em 18 pacientes (9 homens). Conclusões: Parâmetros dos potenciais visuais evocados por padrões reversos normais foram encontrados neste grupo de 20 pacientes com suspeita de simulação. Esta técnica eletrofisiológica pode ser útil como uma medida da integridade do sistema visual nesta população de doentes.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Young Adult , Vision Disorders/diagnosis , Vision Disorders/physiopathology , Evoked Potentials, Visual/physiology , Malingering/diagnosis , Malingering/physiopathology , Photic Stimulation , Time Factors , Visual Pathways/physiopathology , Brazil , Visual Acuity/physiology , Blindness/diagnosis , Blindness/physiopathology , Reproducibility of Results , Retrospective Studies , Hospitals, University
4.
Arq. neuropsiquiatr ; Arq. neuropsiquiatr;73(4): 309-313, 04/2015. graf
Article in English | LILACS | ID: lil-745756

ABSTRACT

Objective : To verify the relationship between intracranial pressure and flash visual evoked potentials (F-VEP) in patients with cryptococcal meningitis. Method The sample included adults diagnosed with cryptococcal meningitis admitted at a reference hospital for infectious diseases. The patients were subjected to F-VEP tests shortly before lumbar puncture. The Pearson’s linear correlation coefficient was calculated and the linear regression analysis was performed. Results : Eighteen individuals were subjected to a total of 69 lumbar punctures preceded by F-VEP tests. At the first lumbar puncture performed in each patient, N2 latency exhibited a strong positive correlation with intracranial pressure (r = 0.83; CI = 0.60 - 0.94; p < 0.0001). The direction of this relationship was maintained in subsequent punctures. Conclusion : The intracranial pressure measured by spinal tap manometry showed strong positive association with the N2 latency F-VEP in patients with cryptococcal meningitis. .


Objetivo : Verificar a relação entre pressão intracraniana e potencial evocado visual por flash (PEV-F) em pacientes com meningite criptocócica. Método A amostra incluiu pacientes admitidos em um hospital de referência para doenças infecciosas. Realizou-se PEV-F antes de cada punção lombar. Calculou-se o coeficiente de correlação de Pearson e a equação de regressão linear entre as variáveis latência N2 e pressão intracraniana inferida através de raquimanometria. Resultados Dezoito pacientes foram submetidos a um total de 69 punções lombares. A latência N2 mostrou correlação positiva forte com a pressão de abertura verificada na primeira punção lombar a que cada paciente foi submetido (r = 0,83; IC = 0,60 – 0,94; p < 0,0001). A positividade da correlação foi mantida nas aferições subsequentes. Conclusão Houve associação positiva forte entre a latência N2 do PEV-F e pressão intracraniana em pacientes com meningite criptocócica. .


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Evoked Potentials, Visual/physiology , Intracranial Hypertension/physiopathology , Intracranial Pressure/physiology , Meningitis, Cryptococcal/physiopathology , Cerebrospinal Fluid Leak/physiopathology , Cerebrospinal Fluid Pressure/physiology , Intracranial Hypertension/etiology , Meningitis, Cryptococcal/complications , Photic Stimulation/methods , Reference Values , Regression Analysis , Spinal Puncture , Time Factors
5.
Arq. bras. oftalmol ; Arq. bras. oftalmol;77(4): 238-242, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-728656

ABSTRACT

Purpose: The goal of this cross-sectional observational study was to quantify the pattern-shift visual evoked potentials (VEP) and the thickness as well as the volume of retinal layers using optical coherence tomography (OCT) across a cohort of Parkinson's disease (PD) patients and age-matched controls. Methods: Forty-three PD patients and 38 controls were enrolled. All participants underwent a detailed neurological and ophthalmologic evaluation. Idiopathic PD cases were included. Cases with glaucoma or increased intra-ocular pressure were excluded. Patients were assessed by VEP and high-resolution Fourier-domain OCT, which quantified the inner and outer thicknesses of the retinal layers. VEP latencies and the thicknesses of the retinal layers were the main outcome measures. Results: The mean age, with standard deviation (SD), of the PD patients and controls were 63.1 (7.5) and 62.4 (7.2) years, respectively. The patients were predominantly in the initial Hoehn-Yahr (HY) disease stages (34.8% in stage 1 or 1.5, and 55.8 % in stage 2). The VEP latencies and the thicknesses as well as the volumes of the retinal inner and outer layers of the groups were similar. A negative correlation between the retinal thickness and the age was noted in both groups. The thickness of the retinal nerve fibre layer (RNFL) was 102.7 μm in PD patients vs. 104.2 μm in controls. Conclusions: The thicknesses of retinal layers, VEP, and RNFL of PD patients were similar to those of the controls. Despite the use of a representative cohort of PD patients and high-resolution OCT in this study, further studies are required to establish the validity of using OCT and VEP measurements as the anatomic and functional biomarkers for the evaluation of retinal and visual pathways in PD patients. .


Objetivo: Este estudo observacional transversal controlado visou quantificar os potenciais evocados visuais com estímulo de padrões alternantes (PEV), a espessura e o volume das camadas retinianas com tomografia de coerência óptica (TCO) num grupo de pacientes com doença de Parkinson (DP). Métodos: Quarenta e três pacientes com DP e 38 controles. Procedimentos: pacientes e controles foram submetidos a exames neurológico e oftalmológico detalhados, sendo incluídos pacientes com DP idiopática e excluídos casos com glaucoma ou aumento da pressão intraocular. Todos os participantes foram estudados com PEV e TCO de Fourier, sendo quantificadas as latências de P100, a espessura e o volume das camadas retinianas interna e externa. Resultados: A média das idades e desvio-padrão dos pacientes com DP e controles foram respectivamente 63,1(7,5) e 62,4 (7,2) anos. Os pacientes com DP situaram-se predominantemente nos estágios iniciais de Hoehn-Yahr (34.8% no estágio 1 ou 1.5; 55.8 % no estágio 2). Não foram observadas diferenças entre os dois grupos quanto às latências dos PEV, a espessura e o volume das camadas retinianas. Observamos uma correlação negativa entre a espessura das camadas retinianas e a idade em ambos os grupos. Não se observou diferença significativa quanto à espessura da camada retiniana das fibras do nervo óptico (CRFNO), que foi de 102,7 μm nos pacientes e 104,2 μm nos controles. Conclusões: A espessura das camadas retinianas, os PEV e a espessura da CRFNO foi semelhante nos pacientes com DP e controles. Apesar desse grupo representativo de pacientes com DP e da alta resolução da TCO utilizada neste estudo, mais estudos são necessários para estabelecer o papel da TCO e dos PEV como biomarcadores anatômico e funcional na avaliação ...


Subject(s)
Female , Humans , Male , Middle Aged , Evoked Potentials, Visual , Parkinson Disease/physiopathology , Retina/anatomy & histology , Tomography, Optical Coherence/methods , Case-Control Studies , Cross-Sectional Studies , Fourier Analysis
6.
Rev. bras. oftalmol ; 71(5): 328-330, set.-out. 2012.
Article in English | LILACS | ID: lil-654995

ABSTRACT

Citicoline may be used in many neurological disorders. Combined treatment of citicoline with patching in amblyopia has previously been researched. The purpose of this paper is to illustrate the effect of citicoline in non-patching amblyopic patient. A 11-year-old amblyopic boy underwent complete ophthalmological examinations, including VEP with flash and pattern stimulus. Two averages of 100 sweep were performed for flash stimulus. Pattern reversal stimulus obtained with high contrast was performed with 60', 30' and 15' checks stimuli. The VEP was repeated 90 days later after a therapy with citicoline and vitamin and the results compared with the responses of the previous recording session. The visual acuity (VA) was 0,7 in the RE and 1,0 in the LE. The VEP pattern amplitude was normal in both eyes. Delayed in latency was detected for all spatial frequency stimulus (SFS) in the RE. Delay in latency was detected only for high SFS in the LE. After the treatment, the VA was 1,0 in both eyes. The latency was normalized with low SFS on the RE and with high SFS on the LE. The flash VEP was normal before and after the therapy. In conclusion, the citicoline demonstrated that it was effective in the treatment of amblyopic eye without patching. The VA and the VEP latency improvement demonstrated that the citicoline enhance the transmission of the electric impulse from retina to visual cortex. Further research is required to understand the immediate and long-term effect of coline treatment in amblyopic patients.


A citicolina pode ser utilizada em vários problemas neurológicos. O tratamento combinado de citicolina e oclusão na ambliopia já foi previamente relatado. O objetivo deste estudo é ilustrar o efeito da citicolina em paciente amblíope sem o tratamento oclusivo. Um menino de 11 anos de idade foi submetido a um exame oftalmológico completo incluindo PEV do tipo flash e do tipo padrão reverso. Para o PEV tipo flash, foram analisadas duas médias de 100 estímulos cada uma. Para o PEV do tipo padrão reverso, foram utilizados estímulos de alto contraste de 60', 30' e 15'. O PEV foi repetido 90 dias depois do tratamento com citicolina e vitaminas e os resultados comparados com os exames antes do tratamento. A acuidade visual era de 0,7 no olho direito e 1,0 no olho esquerdo. A amplitude do PEV era normal em ambos os olhos. Era presente um aumento da latência a todas as frequências espaciais de estimulação (FEE) no olho direito e somente à alta FEE no olho esquerdo. Após o tratamento, a acuidade visual era de 1,0 em ambos os olhos. A latência se normalizou à baixa FSS no olho direito e à alta FSS no olho esquerdo. O PEV tipo flash era normal antes e depois do tratamento. Em conclusão, a citicolina demonstrou ser eficaz no tratamento de olhos amblíopes sem oclusão. A melhora da acuidade visual e da latência do PEV demonstraram que a citicolina restaura a transmissão elétrica do impulso da retina ao cortex visual. Pesquisas futuras são necessárias para entender o efeito imediato e a longo prazo da citicolina no tratamento de pacientes amblíopes.


Subject(s)
Humans , Male , Child , Amblyopia/drug therapy , Cytidine Diphosphate Choline/therapeutic use , Evoked Potentials, Visual , Nootropic Agents/therapeutic use , Visual Acuity
7.
Arq. bras. oftalmol ; Arq. bras. oftalmol;74(1): 37-43, Jan.-Feb. 2011. ilus, graf, tab
Article in English | LILACS | ID: lil-589937

ABSTRACT

PURPOSES: To standardize and validate the technique of axonal electrovisiogram (AxEvg), defining its normative values and parameters and characterizing its findings in normal individuals. METHODS: We enrolled 140 normal individuals (280 eyes) divided into seven groups according to age, each one with 10 males and 10 females. The technique was based on monocular visual stimulation by a 0 dB intensity bright flash on Ganzfeld bowl at a presentation rate of 1.4 Hz. Golden cup electrodes were used and electrical waves were acquired after artifact rejection. For each amplitude and implicit time peak we calculated the mean, median, pattern deviation, minimum and maximum values and 95 percent confidence interval. RESULTS: Monocular visual stimulation with bright flash under mesopic conditions was the standard technical procedure established. The normal AxEvg waveform consists of an initial positive wave (named P1, with mean amplitude of 2.0 mV and mean implicit time peak of 23.1 ms) followed by a negative wave (named N1, with mean amplitude of -3.9 mV and mean implicit time peak of 41.4 ms). No significant differences were observed between males and females or between right and left eyes, but there was an increased P1 and N1 implicit time peaks according to age. Implicit time characteristics suggest that P1 wave represents an optic nerve electrical potential and N1 wave represents an inner retinal layers potential. CONCLUSIONS: AxEvg can be considered a pre-chiasmatic visual evoked potential capable to reliably record the electrical activity of optic nerve and inner retina. The findings suggest that AxEvg may be useful as an electrophysiological test in the diagnosis of neuroretinal diseases.


OBJETIVOS: Padronizar e validar a técnica de realização do eletrovisuograma axonal (EVA), definir seus valores normativos e caracterizar os achados em indivíduos normais. MÉTODOS: Estudo descritivo com 140 indivíduos (280 olhos) normais. Os participantes foram divididos em sete grupos de acordo com a idade, cada qual com 10 indivíduos do sexo masculino e 10 do sexo feminino. Definiu-se como técnica de exame a estimulação monocular por flash luminoso com intensidade de 0 dB na cúpula de Ganzfeld a uma frequência de 1,4 Hz. Foram utilizados eletrodos com cúpula de ouro e foram analisados os traçados elétricos obtidos após rejeição de artefatos. Para cada amplitude e tempo de culminação foram calculados a média, a mediana, o desvio-padrão, os valores mínimo e máximo e o intervalo de confiança de 95 por cento representando uma faixa de normalidade para os valores. RESULTADOS: A técnica de exame padronizada foi a estimulação visual monocular por flash em condições mesópicas. O traçado normal do eletrovisuograma axonal consistiu numa onda positiva inicial (P1, com amplitude média de 2,0 mV e tempo de culminação médio de 23,1 ms) seguida de uma onda negativa (N1, com amplitude média de -3,9 mV e tempo de culminação médio de 41,4 ms). Não foram observadas diferenças significativas entre os sexos e entre os olhos direito e esquerdo, mas os tempos de culminação de P1 e de N1 aumentaram proporcionalmente com a idade. CONCLUSÕES: O eletrovisuograma axonal é um exame de potencial visual evocado pré-quiasmático, capaz de registrar de forma confiável e reprodutível a atividade elétrica do nervo óptico e da retina interna, podendo ser utilizado na propedêutica eletrofisiológica na investigação de lesões neurorretinianas.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Female , Humans , Infant , Male , Middle Aged , Young Adult , Axons/physiology , Evoked Potentials, Visual/physiology , Optic Nerve/physiology , Retina/physiology , Electroretinography , Photic Stimulation , Reference Values
8.
Arq. bras. oftalmol ; Arq. bras. oftalmol;71(4): 475-479, jul.-ago. 2008. graf, tab
Article in English | LILACS | ID: lil-491874

ABSTRACT

PURPOSE: To determine age norms for grating visual acuity and interocular acuity differences measured by the sweep-visually evoked potentials (VEP) technique in the first three years of life. METHODS: Monocular grating visual acuity was measured using the sweep-VEP in 67 healthy normal infants and children in the first 36 months of life. RESULTS: Sweep-VEP grating acuity ranged from 0.80 logMAR (20/125 Snellen equivalent) in the first month of life to 0.06 logMAR (20/20 Snellen equivalent) at 36 months of age. Lower normal limits (95th percentile limit) ranged from 0.95 logMAR (20/180) to 0.12 logMAR (20/25) with a progression of approximately 3 octaves in the first 36 months of age. The largest acceptable interocular acuity difference for clinical purposes was 0.10 logMAR. CONCLUSIONS: Age norms for grating acuity along with interocular acuity differences were determined using the sweep-VEP technique. These norms should be incorporated in clinical practice for precise diagnosis of visual status in infants and preverbal children.


OBJETIVOS: Propor valores normativos de acuidade visual de grades e sua respectiva diferença interocular medidas pelo potencial visual evocado de varredura nos primeiros três anos de vida. MÉTODOS: Foram avaliadas 67 crianças sadias, sem doenças oculares, que tiveram a acuidade visual medida pelos potenciais evocados visuais de varredura. RESULTADOS: A acuidade visual média variou de 0,80 logMAR (equivalente de Snellen de 20/125) no primeiro mês de vida a 0,06 logMAR (equivalente de Snellen de 20/20) aos 36 meses. Os limites normais inferiores (percentil 95 por cento) variaram de 0,95 logMAR (20/180) a 0,12 logMAR (20/25) com progressão de aproximadamente 3 oitavas nos primeiros 36 meses de vida. A diferença interocular máxima aceitável foi de 0,10 logMAR. CONCLUSÕES: Os valores normativos de acuidade visual e de diferença interocular de acuidade foram obtidos pela técnica do potencial visual evocado de varredura. Propõe-se sua adoção na prática clínica para diagnóstico preciso do estado visual de bebês e de crianças pré-verbais.


Subject(s)
Child, Preschool , Humans , Infant , Evoked Potentials, Visual/physiology , Vision Tests/methods , Vision, Monocular/physiology , Visual Acuity/physiology , Pattern Recognition, Visual/physiology , Reference Values , Sensory Thresholds/physiology
9.
Arq. bras. oftalmol ; Arq. bras. oftalmol;70(4): 713-717, jul.-ago. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-461966

ABSTRACT

OBJETIVO: Descrever os principais fatores intervenientes observados durante a aquisição e análise do exame de eletrorretinograma multifocal (ERGmf), que afetam o registro gráfico das ondas obtidas e portanto sua análise. MÉTODOS: Análise dos fatores de erro observados durante a aquisição de 100 exames seqüenciais de eletrorretinograma multifocal, realizados com o Reti System da Roland Consult, no período de maio a julho de 2005. Os exames de eletrorretinograma multifocal foram realizados conforme recomendações internacionais, respeitando-se os parâmetros preestabelecidos do equipamento, com 61 elementos, e ângulo visual de 30°. Todos os pacientes foram submetidos à avaliação oftalmológica completa, excluindo-se aqueles com transparência inadequada de meios, córneas planas e os incapazes de visualizar as linhas de fixação. RESULTADOS: Os fatores intervenientes, que poderiam causar erros na interpretação dos resultados obtidos, observados e corrigidos durante a realização dos exames foram: fixação excêntrica, movimentação dos olhos, contração do orbicular, contração da musculatura cervical, não-correção adequada, não-transparência adequada do eletrodo corneano, deslocamento do eletrodo em geral para baixo, descentralização do suporte da lente corretora, distância inadequada paciente-monitor em pacientes com alta ametropia, altura inadequada dos olhos em relação ao centro da tela, ruído na freqüência de 60 HZ (rede elétrica) e de campo eletromagnético, impedâncias elevadas. No processamento das ondas, a utilização excessiva de filtros para remoção de ruídos dos registros obtidos, pode interferir na análise dos resultados obtidos. CONCLUSÕES: Cuidados simplesmente observacionais durante a aquisição dos sinais são de importância significativa para a obtenção de registros com boa morfologia e baixo nível de ruído. Permitindo, por meio de sua pronta correção, a análise correta e adequada da amplitude e do tempo implícito dos picos N1 e P1, fundamentais...


PURPOSE: To describe the main intervening factors observed during the acquisition and analysis of multifocal electroretinogram (mfERG), that could affect the recorded signal, the obtained responses and their analysis. METHODS: The error factors observed during the acquisition of 100 sequential multifocal electroretinogram tests, in the period of May to July, 2005 were analyzed. The examinations of multifocal electroretinogram were carried out in agreement with international guideline recommendations, taking into account the established parameters of equipment, with 61 elements, and visual angle of 30°. All patients had been submitted to complete ophthalmologic examination, excluding those with inadequate transparency of ways, flat corneas and those incapable to visualize a central fixation target. RESULTS: The intervening factors, that could cause artifacts and errors in the interpretation of the obtained results, observed and corrected during the acquisition of multifocal electroretinogram were: eccentric or poor fixation, eye movements, orbicular contraction, cervical muscle contraction, inadequate transparency of the corneal electrode, electrode displacement, lens support decentralization, inadequate viewing distance in patients with high refractive errors, eye height inadequacy in relation to the center of the screen, electrical noise in 60 HZ frequency and electromagnetic field and high impedances. Excessive use of filters in wave processing for noise and artifact removal can interfere with the analysis of the obtained results. CONCLUSION: Simple observational cares during signal acquisition are of significant importance to ensure accuracy of the topographical electroretinogram information, good waveform morphology and low noise level register. Through their ready correction, the correct and adjusted analysis of the amplitude and of implicit time of peaks N1, P1 and N2 is reliable. Digital smooth system with specific frequency peak...


Subject(s)
Humans , Electroretinography/methods , Electroretinography/instrumentation , Eye Movements/physiology , Fixation, Ocular/physiology
SELECTION OF CITATIONS
SEARCH DETAIL