Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Dental press j. orthod. (Impr.) ; 28(4): e232338, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1514054

ABSTRACT

ABSTRACT Objective: This study was designed to analyze and compare the cusp and apex movements of the maxillary canines and first molars during canine retraction in the first step of extraction space closure, and to evaluate if these teeth follow a curvilinear (acceleration and/or deceleration) movement rate. Material and Methods: Twenty-five patients (23.3 ± 5.1 years of age) were enrolled. The retraction of the maxillary canines was accomplished using nickel-titanium closed coil springs (100gf) on 0.020-in stainless steel archwire. Oblique cephalograms were traced and superimposed on the anatomic best fit of the maxilla (before the retraction [T0], and after one month [T1], three [T3], five [T5] and seven [T7] months). Statistics was based in a normally distributed data. Multilevel procedures were used to derive polynomials for each of the measurements. Student's t-test and one-way repeated measures ANOVA were conducted. The level of significance of 5% was adopted. Results: Canine cusps and apexes did not follow a quadratic curve regarding horizontal movement (neither accelerate nor decelerate). Canine and molar cusps showed more horizontal movement than apexes (4.80 mm vs. 2.78 mm, and 2.64 mm vs. 2.17 mm, respectively). Conclusions: Canine did not accelerate or decelerate overtime horizontally; the cusps and apexes of the canines and molars showed more horizontal movement and larger rate at the beginning of canine retraction, followed by significantly smaller and constant movement rate after the first month.


RESUMO Objetivo: O objetivo deste estudo foi analisar a movimentação das cúspides e dos ápices de caninos e primeiros molares superiores durante a retração de caninos na primeira fase do fechamento do espaço pós-extração, e avaliar se esses dentes apresentam mudança na taxa de movimentação (aceleração e/ou desaceleração). Material e Métodos: Vinte e cinco pacientes (idade = 23,3 ± 5,1 anos) foram incluídos. A retração dos caninos superiores foi realizada com molas helicoidais fechadas de níquel-titânio (100gf) em arco 0,020" de aço inoxidável. Foram feitos traçados cefalométricos de telerradiografias oblíquas e sobrepostos ao melhor ajuste anatômico da maxila (antes da retração [T0]; após um mês [T1], três meses [T3], cinco meses [T5] e sete meses [T7]). A estatística foi baseada em dados com distribuição normal. Procedimentos multiníveis foram usados para derivar polinômios para cada uma das medidas. Teste t de Student e ANOVA de uma via para medidas repetidas foram realizados, adotando-se um nível de significância de 5%. Resultados: As cúspides e os ápices dos caninos não seguiram uma curva quadrática em relação ao movimento horizontal (sem aceleração ou desaceleração). As cúspides dos caninos e molares apresentaram mais movimento horizontal do que os ápices (4,80 mm vs. 2,78 mm e 2,64 mm vs. 2,17mm, respectivamente). Conclusões: A movimentação horizontal dos caninos não acelerou ou desacelerou ao longo do tempo; as cúspides e os ápices dos caninos e molares apresentaram maior movimento horizontal e maior taxa de movimentação no início da retração dos caninos, seguida por uma taxa de movimentação significativamente menor e constante após o primeiro mês.

2.
Dental press j. orthod. (Impr.) ; 26(1): e2119204, 2021. tab, graf
Article in English | LILACS, BBO - Dentistry | ID: biblio-1154065

ABSTRACT

ABSTRACT Objective: Evaluate the height, thickness and cortical density of the palatal bone of adults with different vertical facial patterns using Cone-Beam Computed Tomography (CBCT). Methods: This study analyzed 75 CBCTs of patients between 18 and 35 years old (45 men and 30 women). The CBCTs were classified into three groups based on their facial pattern: normodivergent, hypodivergent and hyperdivergent as determined from lateral cephalograms synthesized from the CBCTs. The height, cortical thickness and cortical density of the palatal bone were measured at 4, 8, 12, 16 and 20mm posterior to the incisive foramen, and at 3, 6 and 9mm lateral to the midpalatal suture. ANOVA with Tukey post-hoc tests were used for analysis of the data, at significance level of p< 0.05. Results: The hypodivergent pattern had a significant difference and the greatest height and cortical thickness of the palatal bone, followed by the hyperdivergent and the normodivergent patterns. No significant differences were found in minimum and maximum values of cortical density. Conclusion: The palatal bone is a favorable anatomical area to install different orthodontic temporary anchorage devices (TADs), where individuals with the hypodivergent vertical facial pattern have a higher height and cortical thickness of the palatal bone, followed by the hyperdivergent pattern and finally the normodivergent pattern. No significant differences in the cortical density of the palatal bone in the three facial patterns were found.


RESUMO Objetivo: Avaliar a altura, a espessura e a densidade cortical do osso palatino em adultos com diferentes padrões faciais verticais, utilizando a tomografia computadorizada de feixe cônico (TCFC). Métodos: O presente estudo analisou 75 TCFCs de pacientes com idades entre 18 e 35 anos (45 homens e 30 mulheres). As TCFCs foram classificadas em três grupos, de acordo com seus padrões faciais: normodivergentes, hipodivergentes e hiperdivergentes, conforme determinado na radiografia cefalométrica lateral reconstruída das TCFCs. Altura, espessura e densidade cortical do osso palatino foram aferidas a 4, 8, 12, 16 e 20 mm para posterior do forame incisivo e a 3, 6 e 9 mm lateralmente à sutura transpalatina. Os testes ANOVA e post-hoc de Tukey foram utilizados para análise dos dados, com nível de significância de p< 0,05. Resultados: O padrão hipodivergente apresentou uma diferença significativa e a maior altura e espessura cortical do osso palatino, seguido pelos padrões hiperdivergente e normodivergente. Nenhuma diferença estatisticamente significativa foi encontrada nos valores mínimos e máximos da densidade cortical. Conclusão: O osso palatino é uma área anatomicamente favorável para instalar diferentes dispositivos de ancoragem temporária. Indivíduos com padrão facial vertical hipodivergente apresentam maior altura e espessura cortical do osso palatino, seguido do padrão hiperdivergente e finalmente do padrão normodivergente. Não foi encontrada qualquer diferença significativa na densidade cortical do osso palatino entre os três padrões faciais.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Dental Implants , Orthodontic Anchorage Procedures , Palate/surgery , Palate/diagnostic imaging , Face , Cone-Beam Computed Tomography
3.
Ortho Sci., Orthod. sci. pract ; 14(53): 80-84, 2021. tab, ilus, graf
Article in Portuguese | BBO - Dentistry | ID: biblio-1223872

ABSTRACT

Resumo Este estudo piloto testou a hipótese de que os dispositivos temporários de ancoragem (DATs) fabricados de Aço 316L são mais resistentes à corrosão, mesmo em meio com flúor, do que os DATs fabricados a partir de ligas de titânio, para tanto foram realizadas medições eletroquímicas em Potenciostato. Materiais e Métodos: Quatro amostras de cada material foram testadas em cada conjunto de teste, a formulação artificial de saliva de Fusayama foi usada como eletrólito solução neste estudo de corrosão in vitro, sem flúor em sua composição e, em um segundo momento, com a concentração de 1500ppM de flúor em sua composição. No teste, uma polarização catódica foi então realizada aumentando essa voltagem por 5 minutos ou até que se obtivessem os pitins de corrosão. Em saliva artificial contendo até 1500ppmF- foi repetido esse teste com novas amostras de cada material em solução de saliva artificial sem a presença de flúor. Resultados: Os resultados de escala de corrente de indução foram inseridos no software OriginPro8 para confecção dos gráficos de valores. Tratando-se de um número reduzido de amostras, para não violar a confiabilidade do estudo, não se realizou teste estatístico. Dentre todas as ligas metálicas utilizadas atualmente, a liga de Ti6Al4V apresentou uma boa resistência à corrosão em saliva artificial. Entretanto a corrosão dessas ligas ocorre em contato com altas concentrações de flúor, diferentemente da liga de Aço 316L, que além da corrosão faz a passivação da superfície. (AU)


Abstract The aim of this pilot study was to test the hypothesis that temporary anchoring devices (TADs) made of 316L steel are more resistant to corrosion even in fluorine environment than DATs manufactured in addition to titanium alloys, for this Potentiostat electrochemical measurements were performed. Materials and Methods: Four pieces of each material were tested in each test set, an application of Fusayama artificial saliva was used as an electrolytic solution in this study of in vitro corrosion, without fluorine in its composition and in a second moment with 1500ppM of fluorine in its composition. In the test, a cathodic polarization was performed by increasing this voltage for 5 minutes or until the corrosion pins were obtained. In artificial saliva containing up to 1500ppmF- this test was repeated with new samples of each material in artificial saliva solution without fluorine. Results: The results of the induction current scale were inserted into OriginPro8 software for making value graphs. As there was a small number of samples, in order not to violate the study's reliability no statistical test was performed. Among all metal alloys currently used the Ti6Al4V alloy showed good resistance to corrosion in artificial saliva. However, the corrosion of these alloys occurs in contact with high fluorine concentration, unlike 316L steel alloy, which in addition to corrosion makes surface passivation. (AU)


Subject(s)
Orthodontic Appliances , Dental Etching , Orthodontic Anchorage Procedures
4.
Braz. dent. sci ; 23(3): 1-7, 2020. tab
Article in English | BBO - Dentistry , LILACS | ID: biblio-1117493

ABSTRACT

Objective: The aim of this systematic review was to compare the clinical failure rate of orthodontic miniscrews in maxilla and mandible. Material and Methods: Randomized controlled trials of patients in orthodontic treatment, which required miniscrews for orthodontic intervention reporting the failure rate of miniscrews in the maxilla and mandible were searched in Pubmed database. Two authors independently reviewed all identified titles and abstracts for eligibility. Comparison between failures in maxilla and mandible were estimated using pairwise meta-analysis to calculate the relative risk (RR) of failure and the 95% confidence intervals using a random-effect model. The reports of randomized trials were assessed for bias using the Cochrane risk of bias tool. Results: Four studies fulfilled the eligibility criteria. 299 patients with a total of 628 miniscrews installed were included in the analysis. The analysis showed a 0.55 RR (95% CI 0.23­1.29) and I2 = 85%. All studies had an unclear risk of bias regarding to the two following items: allocation concealment, blinding of participants and personnel. All studies had a low risk of bias with regard to incomplete outcome data and selective reporting. The results did not demonstrate statistical difference between risk of failure of miniscrew between maxilla and mandible. Conclusion: The results of the meta-analysis showed that miniscrews installed in maxilla presents reduced risk of failure. A tendency of higher number of failures in mandible was also demonstrated. However, results should be interpreted with caution because of the very low quality of included studies and the differences among methodologies. (AU)


Objetivo: A presente revisão sistemática objetivou comparar a taxa de falha clínica de mini-implantes ortodônticos instalados em maxila e mandíbula. Materiais e Métodos: Ensaios clínicos controlados e randomizados que reportaram a taxa de falha de mini-implantes instalados em maxila e mandíbula de pacientes necessitando tratamento ortodôntico foram pesquisados na base de dados do Pubmed. Dois autores revisaram independentemente os títulos e resumos identificados com base nos critérios de elegibilidade. Comparações entre as falhas na maxila e mandíbula foram estimadas utilizando meta-análise pareada para cálculo do risco relativo (RR) de falha e dos intervalos de confiança de 95%, usando um modelo de efeito aleatório. Os reportes dos estudos incluídos foram avaliados quanto ao risco de viés seguindo os critérios da Cochrane para ensaios clínicos randomizados. Resultados: Quatro estudos preencheram os critérios de elegibilidade. No total, 299 pacientes e 628 mini-implantes instalados foram incluídos na análise. A análise apresentou um RR 0,55 (IC 95% 0,23-1,29) e I2 = 85%. Todos os estudos apresentaram um risco claro de viés em relação aos dois itens seguintes: ocultação de alocação, cegamento dos participantes e profissionais. Todos os estudos apresentaram um baixo risco de viés no que diz respeito a dados de desfecho incompletos e reporte seletivo. Não foi demonstrada diferença estatisticamente significativa entre mini-implantes instalados em maxila e mandíbula. Conclusão: Os resultados da meta-análise demonstraram um menor risco de falhas em mini-implantes instalados na maxila e uma tendência para maior número de falhas na mandíbula. Contudo, os resultados devem ser interpretados com cautela, dadas a baixa qualidade dos estudos incluídos e as diferenças entre suas metodologias (AU)


Subject(s)
Dental Implants , Review , Orthodontic Anchorage Procedures , Network Meta-Analysis , Mandible , Maxilla
5.
RFO UPF ; 24(1): 67-72, 29/03/2019. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1048423

ABSTRACT

Objective: To present a case report that used an osseointegrated implant as skeletal anchorage unit in asso-ciation with fixed orthodontic appliance for the treatment of an adult patient with vertical asymmetric skeletal discrepancy. Case report: In this case, the pre-existing osseointegrated implant in the region of element 21 was used as an auxiliary of skeletal anchorage for leveling the upper occlusal plane. This was performed with the straight wire technique, Capelozza prescription pattern I, .022" slot, using the sequence of thermal--activated nickel-titanium arches of .014", .016", .017"X.025" and .019"X.025", followed by the steel arch of.019" X.025". Final considerations: The results presented in this report showed the osseointegrated implant asa good option when used as a resource of auxiliary anchorage in orthodontics, providing better comfort andaesthetic conditions to the treatment and simplifying the technique. (AU)


Objetivo: apresentar um relato de caso em que se utilizou um implante osteointegrado como uni-dade de ancoragem esquelética em associação com aparelho ortodôntico fixo, no tratamento de um paciente adulto com discrepância esquelética vertical assimétrica. Relato do caso: neste caso, foi utilizado o implante osteointegrado pré-existente na região do elemento 21 como auxílio de anco-ragem esquelética para o nivelamento do plano oclusal superior, por meio da técnica straight-wire, prescrição Capelozza padrão I, slot .022", utilizan-do a sequência de arcos de níquel-titânio termo-ativado .014", .016", .017"X.025" e .019X.025", seguido por arco de aço .019" X.025". Conside-rações finais: os resultados apresentados neste re-lato demonstraram ser o implante osteointegrado uma boa opção, quando utilizado como recurso de ancoragem auxiliar em ortodontia, conferindo melhores condições de conforto e estética ao trata-mento, bem como simplificação técnica. (AU)


Subject(s)
Humans , Male , Adult , Dental Occlusion , Orthodontic Anchorage Procedures/methods , Facial Asymmetry/therapy , Orthodontic Appliances, Fixed , Radiography, Panoramic , Treatment Outcome , Facial Asymmetry/diagnostic imaging , Bone-Anchored Prosthesis
6.
Ortho Sci., Orthod. sci. pract ; 10(39): 223-233, 2017. ilua
Article in Portuguese | LILACS, BBO - Dentistry | ID: biblio-868271

ABSTRACT

A expansão rápida da maxila osseossuportada tem sido amplamente utilizada na clínica ortodôntica, entretanto ainda existem dúvidas em relação ao planejamento e efeitos do tratamento. É objetivo do presente artigo relatar um caso clínico descrevendo passo a passo as etapas de planejamento, confecção e instalação do aparelho. Paciente com mordida cruzada posterior, 11 anos de idade foi indicada para tratamento com aparelho. Inicialmente, foi realizada tomografia computadorizada de feixe cônico a fim de planejar o local ideal de instalação de 4 mini-implantes considerando a disponibilidade óssea no palato. Imediatamente após a instalação dos mini-implantes foi realizada moldagem, adaptação de mini-implantes de latão no alginato e confeccionado modelo de trabalho. O disjuntor em acrílico, apoiado apenas nos mini-implantes, foi adaptado em boca e a paciente instruída a ativar o torno expansor » de volta pela manhã e a noite durante 14 dias. Após esse período nova tomografia foi realizada, assim como após o tempo de contenção de 4 meses. Mensurações nas tomografias mostraram expansão maxilar sem efeitos de vestibularização de molares. Após 4 meses foi observada leve redução da expansão esquelética e inclinação lingual dos dentes posteriores. Pode ser concluído que o tratamento foi bem sucedido, resultando em correção da mordida cruzada posterior sem efeitos colaterais nos dentes posteriores.(AU)


Rapid bone-borne maxillary expansion has been widely used in orthodontic clinic, however there are still some doubts about its planning and treatment effects. The aim of this paper is to report a case describing step-by-step planning, manufacturing and installation of the appliance. Patient with posterior crossbite, 11 years-old was indicated to treatment with this appliance. A cone bean computed tomography was achieved to plan the ideal site for installing 4 miniscrews, considering bone availability of the palatal area. Immediately after miniscrews insertion, an impression was taken and miniscrews were inserted in the alginate to obtain the cast model. The acrylic appliance, supported exclusively on miniscrews, was adapted and the patient instructed to activate » turn twice a day for 14 days. After this period a new tomography was obtained and also after a 4-month retention period. Tomography measurements showed maxillary expansion with no molars vestibularization. After 4 months there was a slight decrease on maxillary expansion and molars lingual tipping. It can be concluded that the treatment was successful with correction of the crossbite and no deleterious effects in the posterior teeth.(AU)


Subject(s)
Humans , Female , Child , Cone-Beam Computed Tomography , Orthodontic Anchorage Procedures , Orthodontics , Palatal Expansion Technique
7.
Bauru; s.n; 2016. 81 p. ilus, tab.
Thesis in English | LILACS, BBO - Dentistry | ID: biblio-881296

ABSTRACT

The aim of this study was to assess maxillary, mandibular and glenoid fossa changes after bone anchored maxillary protraction (BAMP) therapy in patients with unilateral complete cleft lip and palate (UCLP). Methods: The experimental group comprised 24 patients with UCLP and maxillary sagittal deficiency with a mean initial age of 11.8 years. Cone-beam computed tomography (CBCT) exams of 24 patients with UCLP taken before (T1) and 18 months (T1) after beginning BAMP therapy were selected from the files of the Hospital of Rehabilitation of Craniofacial Anomalies. CBCTs were superimposed at the cranial base. Three-dimensional displacements of landmarks placed in surface models were quantified and visualized in color-coded maps and semi-transparency superimpositions. Kolmogorov-smirnov test was used to calculate distribution of normality. Paired t test was used to compare cleft and non-cleft sides (p<0.05). Results: A point and non-cleft central incisor displaced toward anterior (1.66mm), inferior (1.21mm) and to the cleft side. Orbitale, Infraorbitale foramen and maxillary first permanent molar displaced similarly toward anterior, inferior and medial direction. The zygoma displaced similarly toward anterior and inferior, however the cleft side showed a significantly greater lateral displacement compared to the non-cleft side. The superior concavity of the glenoid fossa showed symmetrical displacement toward anterior, lateral and superior, while the anterior and posterior eminences showed symmetrical displacements toward anterior, lateral and inferior. The mandible showed an overall symmetrical inferior and posterior displacement except for the medial pole of the condyle, which showed a significantly greater lateral displacement on the cleft side. Conclusions: Maxilla showed an anterior and inferior displacement. The glenoid fossa and the overall mandible symmetrically displaced downward and backward. The zygoma of the cleft side was the only maxillary landmark to show significantly greater lateral displacement than the non-cleft side, as well as the medial pole of the condyle on the cleft side.(AU)


O objetivo deste trabalho foi avaliar as alterações da maxila, mandíbula e fossa glenóide após o tratamento com protração maxilar ancorada em osso (BAMP) em pacientes com fissura unilateral completa de lábio e palato (UCLP). Métodos: o grupo experimental foi composto por 24 pacientes com UCLP e deficiência sagital de maxila com idade inicial de 11,8 anos. Foram selecionados exames de tomografia computadorizada de feixe cônico (CBCT) de 24 pacientes com fissura UCLP realizadas antes e após 18 meses de terapia com BAMP pertencentes ao Hospital de Reabilitação de Anomalias Craniofaciais. Os exames de CBCT foram sobrepostos pela base do crânio. Deslocamentos tridimensionais foram mensurados por meio de pontos colocados em modelos de superfície, bem como foram visualizados em mapas coloridos e sobreposições de semi-transparência. A distribuição de normalidade foi calculada por meio do teste de Kolmogorov-Smirnov. A comparação entre os lados com e sem fissura foi realizada por meio do teste t pareado (p<0.05). Resultados: O ponto A e o incisivo central superior do lado sem fissura deslocaram para anterior (1.66mm), inferior (1.21mm) e para o lado da fissura. Os pontos Orbitário, Forame Infra-orbitário e os primeiros molares permanentes superiores se deslocaram simetricamente para anterior, inferior e medial. O ponto Zigomático deslocou simetricamente para anterior e inferior, porém o lado da fissura apresentou um deslocamento significantemente maior para lateral comparado ao lado sem fissura. A concavidade superior da fossa glenóide apresentou um deslocamento simétrico para anterior, lateral e superior. As eminências anterior e posterior da fossa glenóide apresentaram um deslocamento simétrico para anterior, lateral e inferior. No geral, não houve diferença estatisticamente significante entre os lados com e sem fissura para o deslocamente inferior e posterior da mandíbula. O polo medial do côndilo foi o único ponto em que o lado da fissura apresentou um deslocamento significantemente maior para lateral quando comparado ao lado sem fissura. Conclusões: A maxila mostrou um deslocamento simétrico para anterior e inferior. A fossa glenóide e a mandíbula mostraram um deslocamento simétrico para inferior e para trás. Entretanto, os pontos zigomático e polo medial apresentaram um deslocamento lateral significantemente maior no lado da fissura.(AU)


Subject(s)
Humans , Male , Female , Child , Adolescent , Cleft Lip/therapy , Cleft Palate/therapy , Glenoid Cavity/pathology , Mandible/pathology , Maxilla/pathology , Orthodontic Anchorage Procedures/methods , Palatal Expansion Technique , Anatomic Landmarks , Case-Control Studies , Cleft Lip/pathology , Cleft Palate/pathology , Cone-Beam Computed Tomography , Glenoid Cavity/diagnostic imaging , Imaging, Three-Dimensional , Mandible/diagnostic imaging , Maxilla/diagnostic imaging , Statistics, Nonparametric , Treatment Outcome
8.
Bauru; s.n; 2013. 220 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: lil-707690

ABSTRACT

Este estudo investigou os efeitos do laser em baixa intensidade na movimentação ortodôntica com a intenção de promover a ancoragem e a inibição da dor pós-ativação, bem como a verificação da preservação da integridade tecidual. A amostra constou de um total de 74 molares e pré-molares superiores e inferiores que serviram de ancoragem na fase de retração inicial de caninos realizada com molas de NiTi, com força de 150g. Um dos molares/pré-molares escolhido aleatoriamente foi irradiado com laser de diodo (LI), seguindo o seguinte protocolo de aplicação: 780mm/70mW/105J/cm2/4,2J por ponto/Et= 42J para os molares e 42J para os prémolares nos dias 0, 7 e 14 pós-ativação, sendo que o contralateral foi considerado placebo (LNI). A retração durou em média 3 meses, num total de 9 aplicações de laser. Utilizou-se modelos de gesso e tomografias computadorizadas do feixe cônico (TCFC) para a verificação da perda de ancoragem dos molares. Os modelos adquiridos a cada mês foram medidos com paquímetro digital e as tomografias adquiridas nos tempos iniciais (T0) e finais (T4) foram analisadas por meio da análise 3D (Radiomemory). Nas tomografias foi também avaliada uma possível reabsorção na crista óssea alveolar (CA), por meio da distância desta (CA) até a junção cementoesmalte (JCE), comparando-se T0 e T4 e a quantidade de reabsorção radicular, por meio da diferença de comprimento radicular inicial e final. Para avaliação da sintomatologia dolorosa comparando-se o LI e o LNI foi utilizado uma escala visual analógica após 12, 24, 48 e 72 horas após a irradiação, na qual os pacientes marcavam de 0 a 10 em consonância com a dor experimentada. Para os modelos, empregou-se a análise da variância a dois critérios e a um critério, seguido pelo teste de Tukey, em seguida aplicou-se o teste t pareado, para a mensuração da diferença total comparando-se o lado irradiado (LI) com o lado não irradiado (LNI). Para as tomografias na comparação entre os tempos T0 e T4 da perda de...


This study investigated the effects of low level laser in orthodontic movement, aiming to promote anchorage and inhibition of pain after activation, as well as to analyze the maintenance of tissue integrity after utilization of laser and orthodontic movement. The sample was composed of 74 maxillary and mandibular molars and premolars that served as anchorage in the initial retraction stage of canines, performed with NiTi coil springs with force of 150g. One of the randomly selected molars/premolars was irradiated with diode laser (LI), according to the following application protocol: 780mm/70mW/105J/cm2/4.2J per point/Et= 42J for molars and 42J for premolars at days 0, 7 and 14 after activation, and the contralateral tooth was considered as (LNI). The retraction lasted 3 months in the average, adding up to 9 laser applications. Dental casts and cone beam computed tomographies (CBCT) were evaluated to analyze the anchorage loss of molars. The dental casts obtained every month were measured with a digital pachymeter and the tomographies obtained at initial (T0) and final periods (T4) were assessed by 3D analysis (Radiomemory). The tomographies were also assessed to evaluate a possible resorption of the alveolar bone crest (CA), by measuring the distance between it (CA) and the cementoenamel junction (JCE), comparing T0 and T4 and the quantity of root resorption, by the difference between the initial and final root lengths. The painful symptomatology was analyzed by comparison of LI and LNI using a visual analogue scale after 12, 24, 48 and 72 hours, in which the patients indicated from 0 to 10 according to the pain experienced. For the dental casts, two-way and one-way analysis of variance were applied, followed by the Tukey test and then by the paired t test, for measurement of the total difference comparing the irradiated (LI) and non-irradiated (LNI) sides. The paired t test was applied for comparison between periods T0 and T4 of anchorage loss...


Subject(s)
Humans , Male , Female , Adolescent , Tooth Movement Techniques/methods , Toothache/prevention & control , Orthodontic Anchorage Procedures/methods , Low-Level Light Therapy/methods , Analysis of Variance , Pain Measurement , Reference Values , Time Factors , Treatment Outcome
9.
Araçatuba; s.n; 2011. 83 p. tab, graf, ilus.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-866807

ABSTRACT

Os mini-implantes ortodônticos têm comprovado sua eficiência clínica provendo uma ancoragem absoluta, estes dispositivos podem ser instalados sobre pequenos espaços de tecido ósseo, mas devem ser inseridos efetuando uma técnica cirúrgica muito precisa. Devido ao alto índice de contatos radiculares verificado na literatura científica pela utilização clínica dos mini-implantes, surgiu o interesse para estudar mediante tomografia computadorizada, o posicionamento tridimensional de mini-implantes ortodônticos inseridos através de um guia radiográfico-cirúrgico (RAAG). Foram considerados dois grupos neste estudo, o grupo experimental (GE) prospectivo que incluiu um total de 21 pacientes, 14 pacientes do sexo feminino e 7 do sexo masculino, com 18 anos em média. Neste grupo foram inseridos 21 parafusos ortodônticos auto-perfurantes (POAF) com diâmetro de 1.4mm e 8.0mm de comprimento por um mesmo profissional e utilizou-se um guia radiográfico-cirúrgico Ring Accupunture Auricular Guide (RAAG) com diâmetro de 3.0mm. No grupo controle (Gc) retrospectivo foram inseridos 25 (POAF) na maxila sem nenhum tipo de guia radiográfico-cirúrgico, este grupo controle (Gc) incluiu 10 pacientes do sexo feminino e 15 do sexo masculino com 18 anos em média, cada um dos POAF foi instalado por diferentes profissionais. Após a inserção dos POAF todos os 46 pacientes foram submetidos a Tomografia Dental Computadorizada mediante o Tomógrafo ICAT CONE BEAM. Para a comparação entre os grupos de estudados neste ensaio, foram utilizados os testes Kruskall Wallis e “t” de Student. O grupo experimental GE apresentou uma porcentagem de 88% de inserção equidistante de POAF, evidenciando significância estatística em relação ao grupo Gc. O lado direito do grupo experimental GE apresentou melhor posicionamento dos POAF, evidenciando significância estatística em relação ao lado esquerdo do mesmo GE. Os grupos controle Gc1 e Gc2 apresentaram 100% falhas de posicionamento dos POAF, em relação ao centro...


Introduction: Orthodontic Mini-Screws Self Drilling (ODMS) has proven to be effective providing an efficient absolute anchorage. It could be placed in restricted sites, but requiring a precise surgical technique. Recently (ODMS) have become more popular, thus problems has emerged for example; root contact, would lead to perforation or cause other root injuries. However, no systematic study has evaluated the tridimensional position of (ODMS) into the alveolar process, thus in order to diminish iatrogenic root damage a rapid insertion radiographic surgical guide (RAAG) was proposed to place (ODMS) precisely in the interradicular bone. A specific tomography software was used to evaluated the tridimensional position of (ODMS) and its inaccuracy was estimated

Subject(s)
Humans , Male , Female , Adolescent , Cone-Beam Computed Tomography , Orthodontic Anchorage Procedures , Orthodontics
10.
Araçatuba; s.n; 2011. 83 p. tab, graf, ilus.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: lil-711319

ABSTRACT

Os mini-implantes ortodônticos têm comprovado sua eficiência clínica provendo uma ancoragem absoluta, estes dispositivos podem ser instalados sobre pequenos espaços de tecido ósseo, mas devem ser inseridos efetuando uma técnica cirúrgica muito precisa. Devido ao alto índice de contatos radiculares verificado na literatura científica pela utilização clínica dos mini-implantes, surgiu o interesse para estudar mediante tomografia computadorizada, o posicionamento tridimensional de mini-implantes ortodônticos inseridos através de um guia radiográfico-cirúrgico (RAAG). Foram considerados dois grupos neste estudo, o grupo experimental (GE) prospectivo que incluiu um total de 21 pacientes, 14 pacientes do sexo feminino e 7 do sexo masculino, com 18 anos em média. Neste grupo foram inseridos 21 parafusos ortodônticos auto-perfurantes (POAF) com diâmetro de 1.4mm e 8.0mm de comprimento por um mesmo profissional e utilizou-se um guia radiográfico-cirúrgico Ring Accupunture Auricular Guide (RAAG) com diâmetro de 3.0mm. No grupo controle (Gc) retrospectivo foram inseridos 25 (POAF) na maxila sem nenhum tipo de guia radiográfico-cirúrgico, este grupo controle (Gc) incluiu 10 pacientes do sexo feminino e 15 do sexo masculino com 18 anos em média, cada um dos POAF foi instalado por diferentes profissionais. Após a inserção dos POAF todos os 46 pacientes foram submetidos a Tomografia Dental Computadorizada mediante o Tomógrafo ICAT CONE BEAM. Para a comparação entre os grupos de estudados neste ensaio, foram utilizados os testes Kruskall Wallis e “t” de Student. O grupo experimental GE apresentou uma porcentagem de 88% de inserção equidistante de POAF, evidenciando significância estatística em relação ao grupo Gc. O lado direito do grupo experimental GE apresentou melhor posicionamento dos POAF, evidenciando significância estatística em relação ao lado esquerdo do mesmo GE. Os grupos controle Gc1 e Gc2 apresentaram 100% falhas de posicionamento dos POAF, em relação ao centro...


Introduction: Orthodontic Mini-Screws Self Drilling (ODMS) has proven to be effective providing an efficient absolute anchorage. It could be placed in restricted sites, but requiring a precise surgical technique. Recently (ODMS) have become more popular, thus problems has emerged for example; root contact, would lead to perforation or cause other root injuries. However, no systematic study has evaluated the tridimensional position of (ODMS) into the alveolar process, thus in order to diminish iatrogenic root damage a rapid insertion radiographic surgical guide (RAAG) was proposed to place (ODMS) precisely in the interradicular bone. A specific tomography software was used to evaluated the tridimensional position of (ODMS) and its inaccuracy was estimated

Subject(s)
Humans , Male , Female , Adolescent , Cone-Beam Computed Tomography , Orthodontic Anchorage Procedures , Orthodontics
SELECTION OF CITATIONS
SEARCH DETAIL
...