ABSTRACT
BACKGROUND: There is limited information on the discrepancy between the spirometric values calculated with diverse spirometric prediction equations in normal children. OBJECTIVE: To determine the differences in percentage predicted (PP) values calculated through thirteen prediction equations (PEs) in healthy Chilean children. METHODS: We compared the PP values for FVC, FEV1, FEF25-75% and FEV1/FVC obtained by applying thirteen PEs, using GLI-2012 as a gold standard reference equation and including race neutral GLI-2022 in the analysis; PP values are from a group of 208 healthy Chilean children aged 7 to 17 years. RESULTS: In boys, the range of differences for FVC between PEs compared to the reference group went from -5.47% to 20.82% and from -6.4% to 19.74% in girls. For FEV1, in girls, the range of differences went from -5.96% to 18.01% and from -5,04% to 20.67% in boys. Significant differences between GLI-2012 PPs and the other PEs were observed more frequently in girls than in boys (p < 0.001). CONCLUSIONS: There is a wide difference between the spirometric PPs values by different PEs, including race neutral GLI-2022. Our findings, especially given the potential interpretative and clinical implications, might suggest the need for conducting standardized, multicenter studies in Latin America to determine which PEs would better fit pediatric populations in this region.
ABSTRACT
An anomalous origin of the right coronary artery from the pulmonary artery case report. The diagnosis was made by angiotomography. Reimplantation of the right coronary artery into the ascending aorta and reconstruction of the pulmonary artery were conducted.
ABSTRACT
BACKGROUND: The factors influencing sedentary time (ST) of individuals with chronic obstructive pulmonary disease (COPD) have not been thoroughly explored. AIM: To identify determinant factors of ST in individuals with stable COPD. METHODS: Individuals with COPD had their ST and variables of physical activity (PA) cross-sectionally assessed during seven days with an activity monitor. Main variables were ST/day (<1.5 METs), steps/day, time/day in light PA (light PA/day, 1.5-2.9 METs) and in moderate-to-vigorous PA (MVPA/day, ≥3 METs). Additional assessments included 6-min walking test (6MWT), Medical Research Council (MRC) scale, lung function and body composition. Multiple linear regression models were built with variables correlating significantly with ST/day. RESULTS: 50 individuals were analyzed (44 % males; 66 ± 8 years; FEV1 50 ± 19%pred). ST/day was 488 ± 160 min (61 ± 15 % of the day). 6MWT, MRC scale, MVPA/day, steps/day and light PA/day correlated significantly with ST expressed as minutes/day or as % of the day. In the multiple regression analyses, variables explaining the variance of ST in minutes/day were MRC scale (1 %) and light PA/day (53 %) (model R2 = .541, p < 0.001) and of ST in % of the day were steps/day (53 %) and light PA/day (46 %) (model R2 = .994, p < 0.001). CONCLUSION: In individuals with COPD, the variance in sedentary time can be explained by dyspnea in daily life, step count and specially time/day in light PA, which reinforces the increase in light PA (rather than necessarily MVPA) as a strategy to reduce sedentary time.
ABSTRACT
Excess exercise ventilation (high ventilation (VÌE)/carbon dioxide output (VÌCO2)) contributes significantly to dyspnea and exercise intolerance since the earlier stages of chronic obstructive pulmonary disease (COPD). A selective pulmonary vasodilator (inhaled nitric oxide) has shown to increase exercise tolerance secondary to lower VÌE/VÌCO2 and dyspnea in this patient population. We aimed to assess whether a clinically more practical option - oral sildenafil - would be associated with similar beneficial effects. In a randomized, placebo-controlled study, twenty-four patients with mild-to-moderate COPD completed, on different days, two incremental cardiopulmonary exercise tests (CPET) one hour after sildenafil or placebo. Eleven healthy participants performed a CPET in a non-interventional visit for comparative purposes with patients when receiving placebo. Patients (FEV1= 69.4 ± 13.5â¯% predicted) showed higher ventilatory demands (VÌE/VÌCO2), worse pulmonary gas exchange, and higher dyspnea during exercise compared to controls (FEV1= 98.3 ±11.6â¯% predicted). Contrary to our expectations, however, sildenafil (50â¯mg; N= 15) did not change exertional VÌE/VÌCO2, dead space/tidal volume ratio, operating lung volumes, dyspnea, or exercise tolerance compared to placebo (P>0.05). Due to the lack of significant beneficial effects, nine additional patients were trialed with a higher dose (100â¯mg). Similarly, active intervention was not associated with positive physiological or sensory effects. In conclusion, acute oral sildenafil (50 or 100â¯mg) failed to improve gas exchange efficiency or excess exercise ventilation in patients with predominantly moderate COPD. The current study does not endorse a therapeutic role for sildenafil to mitigate exertional dyspnea in this specific patient subpopulation. Clinical trial registry: https://ensaiosclinicos.gov.br/rg/RBR-4qhkf4 Web of Science Researcher ID: O-7665-2019.
ABSTRACT
Objective: To explore the feasibility of two magnetic resonance imaging (MRI) sequences-high-resolution T2-weighted (HR T2) and Look-Locker T1 (LL T1) relaxometry-for the investigation focal lung lesions (FLLs). As a secondary objective, we analyzed the diagnostic accuracy of these sequences. Materials and Methods: This was a prospective observational study involving 39 subjects with FLLs scanned in a 1.5-T MRI system with LL T1 relaxometry and HR T2 sequences focused on the FLL region, in addition to a conventional protocol. All images were evaluated by two radiologists, working independently, who were blinded to other findings. Results: Most of the examinations (31 of the LL T1 relaxometry sequences and 36 of the HR T2 sequences) were of adequate diagnostic quality. Nondiagnostic examinations were considered so mainly because of limited coverage of the sequences. Of the FLLs studied, 19 were malignant, 17 were benign, and three were excluded from the accuracy analysis because there was no definitive diagnosis. Although LL T1 relaxometry could not distinguish between benign and malignant lesions, the signal intensity at its first inversion time (160 ms) differed between the two groups. The HR T2 sequence was considered the best sequence for assessing specific morphological characteristics, especially pseudocavities and pleural tags. We found that MRI showed better accuracy than did computed tomography (86% vs. 74%). Conclusion: Both MRI sequences are feasible for the evaluation of FLLs. Images at 160 ms of the LL T1 relaxometry sequence helped distinguish between benign and malignant lesions, and the HR T2 sequence was considered the best sequence for evaluating specific morphological characteristics.
Objetivo: Explorar a viabilidade de imagens de alta resolução T2 (T2 AR) e relaxometria T1 Look-Locker (T1 LL) para lesões pulmonares focais (LPFs). Como objetivo secundário, analisamos a precisão diagnóstica dessas sequências. Materiais e Métodos: Este é um estudo observacional prospectivo com 39 sujeitos com LPFs examinados em um sistema de ressonância magnética 1.5T com imagens T1 LL e T2 AR focadas na região das LPFs, além de um protocolo convencional. As imagens foram avaliadas por dois radiologistas independentes e cegos para o estudo. Imagens de tomografia computadorizada estavam disponíveis, mas foram avaliadas sem conhecimento dos outros resultados. Resultados: A maioria dos exames apresentou qualidade diagnóstica adequada em ambas as sequências (T1 LL em 31 exames e T2 AR em 36). Exames considerados não diagnósticos estavam principalmente relacionados à cobertura limitada das sequências. Das LPFs estudadas, 19 eram malignas, 17 eram benignas e três casos foram excluídos da análise de precisão de malignidade por falta de um diagnóstico definitivo. A relaxometria T1 LL não conseguiu distinguir entre lesões benignas e malignas, mas a análise da intensidade do sinal do primeiro tempo de inversão (160 ms) diferiu entre os grupos. A T2 AR foi considerada a melhor sequência para avaliar características morfológicas específicas, especialmente pseudocavidades e apêndices pleurais. A ressonância magnética teve melhor precisão em comparação com a tomografia computadorizada (86% e 74%, respectivamente). Conclusão: Ambas as sequências são viáveis na avaliação de LPFs. Imagens a 160 ms da sequência T1 LL ajudaram a distinguir lesões benignas de malignas, e a T2 AR foi considerada a melhor sequência na avaliação de algumas características morfológicas específicas.
ABSTRACT
Thromboembolic events incidence is low in pediatrics; high suspicion and explicit management algorithms are essential. We present a 12-year-old female patient with two weeks of dyspnea, orthopnea, and ankle edema. Tests showed metabolic acidosis, hyperlactatemia, elevated D-dimer, and positive SARS-CoV-2 CRP. The echocardiogram showed severe right ventricular dysfunction and supra-systemic pulmonary hypertension. Chest CT angiography showed extensive bilateral pulmonary thromboembolism. Anticoagulant therapy was started. She presented with hemodynamic instability. Adrenaline, norepinephrine, milrinone, and nitric oxide were started. The clinical picture was extremely severe in the first 24 hours. It was decided to perform systemic thrombolysis with alteplase, which led to an improvement. Cardiorespiratory stabilization and anticoagulation are the mainstays of therapy in massive pulmonary thromboembolism. Fibrinolytic therapy is used in selected high-risk cases. In this patient, systemic reperfusion therapy with alteplase was performed with no significant complications.
La incidencia de eventos tromboembólicos es baja en pediatría; es importante la alta sospecha y algoritmos claros de manejo. Presentamos una paciente de 12 años, con 2 semanas de disnea, ortopnea y edema de tobillos. Exámenes evidenciaron acidosis metabólica, hiperlactatemia, dímero D elevado y PCR SARS-CoV-2 positiva. Ecocardiograma con disfunción grave de ventrículo derecho e hipertensión pulmonar suprasistémica. Angio-TAC de tórax mostró extenso tromboembolismo pulmonar bilateral. Se inició terapia anticoagulante. Evolucionó con inestabilidad hemodinámica. Inició adrenalina, norepinefrina, milrinona y óxido nítrico. Primeras 24 horas de extrema gravedad. Se decidió realización de trombólisis sistémica con alteplasa, y evolucionó con progresión a la mejoría. Los pilares de terapia en tromboembolismo pulmonar (TEP) masivo son la estabilización cardiorrespiratoria y la anticoagulación. En casos seleccionados como de alto riesgo, se utiliza terapia fibrinolítica. En esta paciente, se realizó terapia de reperfusión sistémica con alteplasa, sin complicaciones de importancia en el procedimiento.
ABSTRACT
Background: Asthma onset or worsening of the disease in adulthood may be associated with occupational asthma (OA) or work-exacerbated asthma (WEA). Oscillometry and respiratory modeling offer insight into the pathophysiology and contribute to the early diagnosis of respiratory abnormalities. Purpose: This study aims to compare the changes due to OA and WEA and evaluate the diagnostic accuracy of this method. Patients and Methods: Ninety-nine volunteers were evaluated: 33 in the control group, 33 in the OA group, and 33 in the WEA group. The area under the receiver operator characteristic curve (AUC) was used to describe diagnostic accuracy. Results: Oscillometric analysis showed increased resistance at 4 hz (R4, p<0.001), 20 hz (R20, p<0.05), R4-R20 (p<0.0001), and respiratory work (p<0.001). Similar analysis showed reductions in dynamic compliance (p<0.001) and ventilation homogeneity, as evaluated by resonance frequency (Fr, p<0.0001) and reactance area (p<0.0001). Respiratory modeling showed increased peripheral resistance (p<0.0001), hysteresivity (p<0.0001), and damping (p<0.0001). No significant changes were observed comparing OA with WEA in any parameter. For OA, the diagnostic accuracy analyses showed Fr as the most accurate among oscillometric parameters (AUC=0.938), while the most accurate from respiratory modeling was hysteresivity (AUC=0.991). A similar analysis for WEA also showed that Fr was the most accurate among traditional parameters (AUC=0.972), and hysteresivity was the most accurate from modeling (AUC=0.987). The evaluation of differential diagnosis showed low accuracy. Conclusion: Oscillometry and modeling have advanced our understanding of respiratory abnormalities in OA and WEA. Furthermore, our study presents evidence suggesting that these models could aid in the early diagnosis of these diseases. Respiratory oscillometry examinations necessitate only tidal breathing and are straightforward to conduct. Collectively, these practical considerations, coupled with the findings of our study, indicate that respiratory oscillometry in conjunction with respiratory modeling, may enhance lung function assessments in OA and WEA.
ABSTRACT
Resistant M. tuberculosis strains threaten pulmonary tuberculosis (P-TB) control since they limit drug options. Drug repositioning and new development strategies are urgently required to overcome resistance. Studies have already shown the beneficial role of the oral antidiabetic metformin as an anti-tuberculosis adjuvant drug. This work aimed to develop an inhalatory dry powder co-formulation of metformin and moxifloxacin to figure out a future option for P-TB treatment. Pre-formulation evaluations indicated the physicochemical compatibility of constituents, demonstrating powder crystallinity and acceptable drug content. Eight moxifloxacin-metformin dry powder formulations were produced by spray drying, and solid-state characterizations showed partial amorphization, ascribed to moxifloxacin. Four formulations containing L-leucine exhibited micromeritic and in vitro deposition profiles indicating pulmonary delivery suitability, like spherical and corrugated particle surface, geometric diameters < 5 µm, high emitted doses (>85 %), and mass median aerodynamic diameters between 1-5 µm. The use of a second spray dryer model further optimized the aerodynamic properties and yield of the best formulation, demonstrating the influence of the equipment used on the product obtained. Moreover, the final formulation showed high in vitro cell tolerability and characteristics in permeability studies indicative of good drug retention in the lungs.
ABSTRACT
Children are at higher risk of atelectasis due to their anatomical and physiological particularities. Several physiotherapy techniques are used to treat atelectasis, but only four studies cite methods in pediatric patients undergoing Invasive Mechanical Ventilation (IMV). The objective of this study was to evaluate the Structured Respiratory Physiotherapy Protocol (SRPP) for airway clearance and lung reexpansion for infants on IMV with atelectasis. This is a prospective study including 30 infants (mean ± standard deviation age 8.9 ± 8.0 months; weight 7.5 ± 3.0 kg; BMI 15.8 ± 1.6 kg/cm2 and IMV duration 7.7 ± 4.3 days). The sample was randomized into a Control Group (CG), which received routine physiotherapy, and an Intervention Group (IG), submitted to SRPP (postural drainage, mechanical thoracic vibration, manual hyperinflation, stretching of the accessory respiratory muscles, and functional positioning). Both groups were evaluated before and after physiotherapy for respiratory effort using the Wood Downes Score (WD) and pulmonary aeration using lung ultrasonography (Lung Ultrasound Score â LUS). The outcome of the intervention was evaluated by the magnitude of the effect by the Hedges' g test [(small (0.2 < Hedges' g < 0.5), moderate (0.5 < Hedges' g < 0.8) and large (Hedges' g > 0.8) effects]. There were large within-group effects on the reduction of WD in the CG after intervention in both the CG (Hedges' g = -1.53) and IG (Hedges' g = -2.2). There was a moderate effect on LUS reduction in the CG (Hedges' g = -0.64) and a large effect on IG (Hedges' g = -1.88). This study has shown that the SRPP appears to be safe and may be effective in improving airway clearance and lung reexpansion in children on IMV with atelectasis.
Subject(s)
Pulmonary Atelectasis , Respiration, Artificial , Respiratory Therapy , Humans , Pulmonary Atelectasis/therapy , Prospective Studies , Infant , Female , Male , Respiratory Therapy/methods , Respiration, Artificial/methods , Treatment Outcome , Physical Therapy Modalities , Intensive Care Units, Pediatric , Lung/physiopathology , Lung/diagnostic imaging , Clinical ProtocolsABSTRACT
Diffuse pulmonary lymphangiomatosis (DLP) is an extremely rare silent disease, characterized by proliferation and thickening of abnormal pulmonary, pleural, and mediastinal soft tissue lymphatic channels. Its clinical presentation is nonspecific symptoms such as cough, dyspnea, and hemoptysis. Tomographic findings for DLP include thickening of the interlobular septa and peribronchovascular interstitium and ground glass opacities. Nevertheless, the anterior mediastinal mass, associated with thickening of interlobular septa and peribronchovascular interstitial, ground glass opacities, pleural effusion, diffuse infiltration of the mediastinum and pleural thickening in a patient with lymphangiomas, DLP should be suspected as a differential diagnosis.
ABSTRACT
PURPOSE: To report a case of an asymptomatic patient with a pulmonary aneurysmal arterio-venous malformation successfully treated with a vascular plug. CASE REPORT: An active 30-year-old male patient, residing at 3000 ft above sea level was referred due to an incidental finding on a CT scan of a 37 mm vascular mass localized in the lower lobe of the right lung, which corresponded to a pulmonary arteriovenous malformation with a single feeding artery. The patient was treated with an Amplatzer vascular plug, which effectively excluded the afferent vessel. An angio CT at 19 months follow-up revealed a hypodense residual mass of 9.0 mm in diameter with no arterial filling or venous drainage. The patient is fully active and remains asymptomatic at 24 months follow-up. CONCLUSION: An unusual case of a pulmonary aneurysmal arteriovenous malformation successfully treated with a vascular plug is presented, highlighting the efficiency of this procedure.
ABSTRACT
Complete atrioventricular septal defect (CAVSD) can lead to the development of pulmonary obstructive vascular disease due to high pulmonary blood flow and pressures. This study aimed to evaluate the changes in pulmonary hemodynamics with aging and with patent ductus arteriosus (PDA) in children with CAVSD. We retrospectively evaluated 137 children (94% with trisomy 21, median age of 195 (25-2963) days, 58.4% female) with CASVD referred to cardiac catheterization from January 2000 to December 2020. Those with associated congenital heart disease, except PDA, had been excluded. They were divided into three age terciles (T1, T2, and T3). Aging was directly associated with higher mean (T1: 34.2 ± 9.1; T2: 37.1 ± 5.8; T3: 42 ± 10.6 mmHg, p < 0.001) and diastolic (T1: 19.4 ± 5.3; T2 21.6 ± 5.0; T3: 26.0 ± 9.5 mmHg, P < 0.001) pulmonary arterial pressures, and with higher pulmonary vascular resistance (T1: 3.24 ± 1.69, T2: 3.47 ± 1.19; T3: 4.49 ± 3.91 Wu.m2, p = 0.023). This resulted in a loss of eligibility for anatomical correction, which became evident only after 300 days of age. PDA was associated with a higher mean (37.2 [35.9; 38.5] vs. 41.3 [37.5; 45.0] mmHg, p = 0.049) and diastolic (21.7 [20.7; 22.6] vs. 26.4 [24.1; 29.0] mmHg, p = 0.001) pulmonary pressure, and resistor-compliance time (0.28 [0.26; 0.29] vs. 0.36 [0.31; 0.40], p = 0.001) after adjusting for age and sex. In children with CAVSD, aging was associated with worsening of pulmonary vascular hemodynamics, particularly when PDA was associated, resulting in loss of eligibility for anatomical correction after 10 months of age as the first surgical option.
ABSTRACT
In this review, we approach the main morphologic and developmental aspects of the congenital cardiovascular malformation known as tetralogy of Fallot with pulmonary atresia. It is recognized that pulmonary atresia associated with a deficient ventricular septation can occur in several situations. However, the tetralogy presentation in particular, with frequent but not invariable concomitance of systemic-to-pulmonary collateral arteries supplying the lungs entirely or in part, poses surgical challenges. The variations in the morphology of such collateral arteries and the intracardiac anatomy are discussed.
ABSTRACT
Objective: Cryoballoon ablation for pulmonary vein isolation is a time-efficient procedure that can alleviate stress on electrophysiology lab resources. This analysis modeled the impact of cryoballoon ablation on electrophysiology lab operation using data from Latin America. Methods: Data from centers in Argentina, Mexico, Colombia, and Chile of the were used as inputs for an electrophysiology lab efficiency simulation model. The model used the assumption that either two (today's electrophysiology lab operations) or three (including electrophysiology lab operational changes) cryoballoon ablation procedures could be performed per day. The endpoints were the percentage of days that resulted in 1) overtime and 2) time left for an extra non-ablation electrophysiology procedure. Results: Data from a total of 232 procedures from six Latin American centers were included in the analysis. The average electrophysiology lab occupancy time for all procedures in Latin America was 132 ± 62 minutes. In the Current Scenario (two procedures per day), 7.4% of simulated days resulted in overtime, and 81.4% had enough time for an extra electrophysiology procedure. In the Enhanced Productivity Scenario (three procedures per day), 16.4% of days used overtime, while 67.4% allowed time for an extra non-ablation electrophysiology procedure. Conclusions: Using real-world, Latin American-specific data, we found that with operational changes, three ablation procedures could feasibly be performed daily, leaving time for an extra electrophysiology procedure on more than half of days. Thus, use of cryoballoon ablation is an effective tool to enhance electrophysiology lab efficiency in resource-constrained regions such as Latin America.
Objetivos: La ablación con criobalón para el aislamiento de venas pulmonares es un procedimiento que ahorra tiempo y puede ahorrar recursos del laboratorio de electrofisiología. Este análisis modeló el impacto de la ablación con criobalón en el funcionamiento del laboratorio de electrofisiología utilizando datos de América Latina. Métodos: Los datos de los centros de Argentina, México, Colombia y Chile del se utilizaron como datos de entrada para un modelo de simulación de la eficiencia del laboratorio de electrofisiología. El modelo partió del supuesto de que se podían realizar dos (operaciones actuales del laboratorio de electrofisiología) o tres (incluidos los cambios operativos del laboratorio de electrofisiología) procedimientos de ablación con criobalón por día. Los criterios de valoración eran el porcentaje de días en los que se producían 1) horas extraordinarias y 2) tiempo restante para un procedimiento electrofisiológico adicional no relacionado con la ablación. Resultados: Se incluyeron en el análisis los datos un total de 232 procedimientos de seis centros latinoamericanos. El tiempo medio de ocupación del laboratorio de electrofisiología para todos los procedimientos en Latinoamérica fue de 132 ± 62 minutos. En el escenario actual (dos procedimientos por día), el 7,4% de los días simulados resultaron en horas extras, y el 81,4% tuvo tiempo suficiente para un procedimiento de electrofisiología adicional. En el escenario de productividad mejorada (tres procedimientos por día), el 16,4% de los días utilizó horas extraordinarias, mientras que el 67,4% dispuso de tiempo suficiente para un procedimiento electrofisiológico extra sin ablación. Conclusiones: Utilizando datos del mundo real específicos de América Latina, descubrimos que, aplicando cambios operativos, es factible realizar tres procedimientos de ablación al día, lo que deja tiempo para un procedimiento de electrofisiología adicional en más de la mitad de los días. Por lo tanto, el uso de la ablación con criobalón es una herramienta eficaz para mejorar la eficiencia de los laboratorios de electrofisiología en regiones con recursos limitados como América Latina.
Subject(s)
Atrial Fibrillation , Cryosurgery , Pulmonary Veins , Registries , Humans , Cryosurgery/methods , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Latin America , Time FactorsABSTRACT
Background: Lower limb amputation surgery is associated with a high risk of venous thromboembolism. There is evidence that pharmacological thromboprophylaxis is not widely prescribed to patients undergoing this type of procedure. Objectives: To investigate the profile of the thromboprophylaxis practices of angiologists and vascular surgeons in Brazil during the perioperative period of lower limb amputation surgery and conduct a descriptive analysis of the findings. Methods: This is a cross-sectional, descriptive study, with simple probabilistic sampling, carried out with angiologists and vascular surgeons working in Brazil. Data were collected through electronic questionnaires, from February to June 2023. Results: There were 237 respondents, 58.6% of whom conduct thrombotic risk stratification. Of these, 86.3% use the Caprini score. Only 27% of participants stratify patients' bleeding risk. Low molecular weight heparin is the medication of choice for 85.7% of study participants, 78.9% of whom use a dosage of 40 IU per day. Around 46.8% use direct oral anticoagulants in addition to low molecular weight heparin and rivaroxaban is the drug they most often prescribe (94.6%). A little more than half (51.15%) routinely recommend pharmacological thromboprophylaxis until hospital discharge. Conclusions: The study revealed the heterogeneous nature of conduct related to prescription of pharmacological thromboprophylaxis, highlighting the need for more studies to support prophylaxis decision-making in this patient population.
ABSTRACT
OBJECTIVE: To verify the relationship between sarcopenia and sleep in individuals with chronic obstructive pulmonary disease (COPD). METHODS: Individuals with COPD were cross-sectionally assessed for lung function (spirometry), sleep (both subjectively [Pittsburgh Sleep Quality Index, PSQI] and objectively [Actiwatch sleep monitor]) and the presence of sarcopenia (handgrip strength by dynamometry). All tests were carried out in accordance with international standards. RESULTS: Twenty-nine individuals with COPD were analyzed (16 women; 69 ± 7 years; BMI 27 ± 5 kg/m2; FEV1 59 ± 19% predicted). Upon division in groups according to the presence or absence of sarcopenia, individuals with sarcopenia (in comparison to those without sarcopenia) had shorter sleep time (81 [75-85] vs. 86 [81-90] %; p = 0.043), lower sleep efficiency (77 [69-83] vs. 85 [75-87] %; p = 0.038), longer time awake after sleep onset (92 [71-120] vs. 58 [47-83] minutes; p = 0.0012) and more marked sleep fragmentation, represented by a higher number of sleep blocks/night (46 [41-49] vs. 34 [26-48]; p = 0.018), higher number of awake blocks/night (45 [40-49] vs. 34 [26-48]; p = 0.018) and shorter duration of sleep blocks/night (9 [8-10] vs. 14 [8-58] minutes; p = 0.043). There was no statistical difference when comparing the PSQI variables between the groups. However, handgrip strength was negatively associated with PSQI components 2 [R= -0.51, p = 0.005] and 5 [R= -0.39, p = 0.037]. CONCLUSION: Individuals with COPD and sarcopenia (as measured by handgrip strength) have worse objectively measured sleep outcomes. This was not the case regarding a self-reported perception of worse sleep quality, although there was weak-to-moderate association between handgrip strength and subjective sleep.
ABSTRACT
BACKGROUND: Pulmonary artery trunk aneurysm (PATA) is a rare and complex vascular anomaly characterized by the abnormal dilation of the initial portion of the pulmonary artery, posing significant diagnostic and therapeutic challenges. PURPOSE: This clinical case report aims to describe the follow-up of a patient with PATA, emphasizing the role of imaging in diagnosis and monitoring, as well as discussing potential associations with other conditions. RESEARCH DESIGN: The study is designed as a clinical case report, detailing the longitudinal follow-up of a single patient with PATA. STUDY SAMPLE: The subject of this study is a 48-year-old female patient with a history of idiopathic hypertension who developed a PATA. Data Collection and/or Analysis: Since 2010, the patient underwent various imaging exams, including echocardiography, computed tomography, and catheter angiography, to detect and evaluate the aneurysm at different stages. RESULTS: The imaging results indicated a progression of the aneurysm over time, underscoring the importance of imaging in the early identification and monitoring of PATA. The report also explores the possible association of PATA with conditions such as pulmonary hypertension, Behçet's disease, and Hughes-Stovin syndrome, highlighting the diagnostic complexity. CONCLUSIONS: Imaging diagnosis is crucial for the detection, characterization, and monitoring of PATA, providing essential information for selecting appropriate treatment options and achieving a satisfactory prognosis. An individualized treatment approach, considering both medical and surgical options, is necessary based on the clinical characteristics of each patient.
ABSTRACT
The distribution of pulmonary blood flow is uneven and can be described as a three-zone model, the West zones: zone 1 occurs whenever alveolar pressure exceeds arterial pressure; zone 2 when the arterial pressure is greater than alveolar but the alveolar pressure exceeds the venous pressure; and finally zone 3 when both arterial and venous pressures exceed alveolar pressure. Consequently, the blood flow is almost determined by the difference between the arterial and venous pressures in zone 3 and between arterial and alveolar pressures in zone 2 and ceases in zone 1. The understanding of this subject may be difficult to some medical students. Therefore, to improve the learning of this topic in our physiology course, we used a didactic model to demonstrate the core concept of flow down gradients and its application to pulmonary blood flow. We modeled a Starling resistor by placing a collapsible tube inside a hermetic chamber of variable pressure. Transparent turbine flowmeters were connected to the upstream and downstream extremities of the Starling resistor, and we generated a constant airflow with a brushless motor. By maintaining the input (arterial) pressure constant and varying the chamber (alveolar) pressure, we could simulate the three zones and demonstrate the resulting flow through the turbines. In conclusion, our demonstration using a Starling resistor model combined with visible turbine flowmeters can be used to facilitate comprehension of important concepts in physiology involving flow down gradients, such as pulmonary blood flow.NEW & NOTEWORTHY The understanding of respiratory physiology is a challenge to medical students. To improve the learning of pulmonary blood flow distribution through lung vessels in our physiology course, we modeled a Starling resistor model combined with visible turbine flowmeters. Our model can significantly improve the core concept of flow down gradients teaching and its application to West zones.