Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49.804
Filter
1.
Adv Sci (Weinh) ; : e2403028, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38946620

ABSTRACT

Superhydrophobic surfaces (SHS) exhibit a pronounced ability to resist wetting. When immersed in water, water does not penetrate between the microstructures of the SHS. Instead, a thin layer of trapped gas remains, i.e., plastron. This fractional wetting is also known as the Cassie-Baxter state (CB). Impairment of superhydrophobicity occurs when water penetrates the plastron and, when complete wetting is achieved, a Wenzel state (W) results. Subsequent recovery back to CB state is one of the main challenges in the field of SHS wetting. Current methods for plastron recovery require complex mechanical or chemical integration, are time-consuming or lack spatial control. Here an on-demand, contact-less approach for performing facile transitions between these wetting states at micrometer length scales is proposed. This is achieved by the use of acoustic radiation force (ARF) produced by high-intensity focused ultrasound (HIFU). Switching from CB to W state takes <100 µs, while the local recovery back to CB state takes <45 s. To the best of authors knowledge, this is the first demonstration of ARF-induced manipulation of the plastron enabling facile two-way controlled switching of wetting states.

2.
Mol Imaging Radionucl Ther ; 33(2): 106-108, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38949459

ABSTRACT

Tc-99m methylene diphosphonate (MDP) is a bone imaging agent used for skeletal staging, but it can also be localized in extraosseous calcifying lesions. We report a case of an 84-year-old woman with breast carcinoma who underwent surgery followed by radiotherapy 10 years ago and now presented with a right axillary mass referred for Tc-99m MDP to exclude bone metastasis. Tc-99m MDP shows intense tracer uptake in the right thoracic region corresponding to the site of calcified soft tissue mass in the right lateral chest wall. Subsequent ultrasonography revealed an ill-defined lesion containing coarse calcifications. Biopsy showed radiation-induced sarcoma. Extra osseous Tc-99m MDP uptake may provide important diagnostic information that may alter patient management.

3.
Heliyon ; 10(12): e32598, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38952362

ABSTRACT

Radiotherapy causes apoptosis mainly through direct or indirect damage to DNA via ionizing radiation, leading to DNA strand breaks. However, the efficacy of radiotherapy is attenuated in malignant tumor microenvironment (TME), such as hypoxia. Tumor vasculature, due to the imbalance of various angiogenic and anti-angiogenic factors, leads to irregular morphology of tumor neovasculature, disordered arrangement of endothelial cells, and too little peripheral coverage. This ultimately leads to a TME characterized by hypoxia, low pH and high interstitial pressure. This deleterious TME further exacerbates the adverse effects of tumor neovascularization and weakens the efficacy of conventional radiotherapy. Whereas normalization of blood vessels improves TME and thus the efficacy of radiotherapy. In addition to describing the research progress of radiotherapy sensitization and vascular normalization, this review focuses on the strategy and application prospect of modulating vascular normalization to improve the efficacy of radiotherapy sensitization.

4.
Heliyon ; 10(12): e32711, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38952365

ABSTRACT

Recently, investigation of advanced shielding materials to be used as an alternative to lead apron has become important. In the current study, MgO loaded into PVC matrix as a non-lead modern shielding composite was modeled to evaluate its performance on radiation protective clothing (RPC). Parameters such as mass attenuation coefficient (MAC), mean free path (MFP), flux buildup factor (FBF), transmission factor (TF) and lead equivalent value (LEV) of samples were calculated using MCNPX Code. The simulation of the MCNP code was validated, by comparing the mass attenuation of concrete sample, with standard XCOM data and very good agreement was attended between XCOM and MC Code results. The MAC of nano and micro-sized samples were also compared with pure PVC and it was found that the nano MgO particle exhibits higher attenuation compared to micro MgO particle and pure PVC. The results show that, the MAC of samples increased to 63.13 % in 1.332 MeV with increasing filler concentration of nano MgO to 50 wt% relative to pure PVC. Investigation of LEV shows that nano MgO sample has more effective than Pb in 1.173 and 1.332 MeV gamma ray energy so that it provides 36.46 % and 11.13 % lighter RPC than Pb ones.

5.
Front Oncol ; 14: 1356592, 2024.
Article in English | MEDLINE | ID: mdl-38952559

ABSTRACT

Primary cardiac malignant tumors are extremely rare, making up about 10% of all primary cardiac tumors. Most of these tumors are primary sarcomas, with primary mesothelioma being even less common. This report details a 53-year-old male patient diagnosed with primary cardiac malignant mesothelioma. The patient had symptoms of chest pain and difficulty breathing. A CT scan showed an enlarged heart, fluid around the heart, and irregular thickening of the pericardium. Diagnosis was confirmed through a surgical biopsy, which showed the presence of malignant mesothelioma. After the procedure, the patient received appropriate cardiac support. Although stable at discharge, the patient unfortunately died three months later due to severe wheezing. There may be a potential link between exposure to radioactive iodine treatment and this outcome. This case highlights the diagnostic and treatment challenges of primary cardiac malignant tumors and reminds physicians to consider this rare disease when evaluating patients with similar symptoms.

6.
Front Public Health ; 12: 1410722, 2024.
Article in English | MEDLINE | ID: mdl-38952739

ABSTRACT

Radiological science and nuclear technology have made great strides in the twenty-first century, with wide-ranging applications in various fields, including energy, medicine, and industry. However, those developments have been accompanied by the inherent risks of exposure to nuclear radiation, which is a source of concern owing to its potentially adverse effects on human health and safety and which is of particular relevance to medical personnel who may be exposed to certain cancers associated with low-dose radiation in their working environment. While medical radiation workers have seen a decrease in their occupational exposure since the 1950s thanks to improved measures for radiation protection, a concerning lack of understanding and awareness persists among medical professionals regarding these potential hazards and the required safety precautions. This issue is further compounded by insufficient capabilities in emergency response. This highlights the urgent need to strengthen radiation safety education and training to ensure the well-being of medical staff who play a critical role in radiological and nuclear emergencies. This review examines the health hazards of nuclear radiation to healthcare workers and the awareness and willingness and education of healthcare workers on radiation protection, calling for improved training programs and emergency response skills to mitigate the risks of radiation exposure in the occupational environment, providing a catalyst for future enhancement of radiation safety protocols and fostering of a culture of safety in the medical community.


Subject(s)
Health Personnel , Occupational Exposure , Radiation Protection , Humans , Occupational Exposure/prevention & control , Radioactive Hazard Release , Radiation Injuries/prevention & control , Health Knowledge, Attitudes, Practice , Awareness
7.
BJU Int ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38953550

ABSTRACT

OBJECTIVES: To evaluate the utility of the 17-gene Genomic Prostate Score® (GPS; MDxHealth, Irvine, CA, USA) performed on prostate cancer at the positive margin of the radical prostatectomy (RP) for its association with risk of subsequent biochemical recurrence (BCR). PATIENTS AND METHODS: We designed a case-cohort for the outcome of BCR, selecting 223 from a cohort of 813 RP patients treated at Johns Hopkins from 2008 to 2017 with positive margins and available clinical data; of these, 213 had available tissue and clinical data. RNA was isolated from formalin-fixed paraffin-embedded tumour tissue adjacent to the positive surgical margin and the GPS was evaluable in 203 of these patients with a score ranging from 0 to 100, with higher scores indicating higher risk. All patients underwent RP with or without adjuvant radiation therapy (ART). The statistical analysis employed Cox proportional hazards regression models for outcome of BCR weighted for case-cohort design. RESULTS: In univariable analysis, every 20-unit increase in the GPS was associated with a nearly threefold increase in risk of BCR (hazard ratio [HR] per 20 units 2.82, P < 0.001). In a multivariable Cox model adjusted for age, race, Cancer of the Prostate Risk Assessment Postsurgical score, Grade Group at the positive margin, and ART, the GPS was significantly associated with BCR (HR 1.56 per 20 units; 95% confidence interval 1.11-2.19; P = 0.011). The study is limited by its retrospective and single institution design. CONCLUSIONS: The GPS at the positive surgical margin could help stratify prognosis and inform clinical decision-making regarding adjuvant therapy after RP.

8.
Int J Radiat Biol ; : 1-9, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38953797

ABSTRACT

PURPOSE: Chromosomal dicentrics and translocations are commonly employed as biomarkers to estimate radiation doses. The main goal of this article is to perform a comparative analysis of yields of both types of aberrations. The objective is to determine if there are relevant distinctions between both yields, allowing for a comprehensive assessment of their respective suitability and accuracy in the estimation of radiation doses. MATERIALS AND METHODS: The analysis involved data from a partial-radiation simulation study with the calibration data obtained through two scoring methods: conventional and PAINT modified. Subsequently, a Bayesian bivariate zero-inflated Poisson model was employed to compare the posterior marginal density of the mean of dicentrics and translocations and assess the differences between them. RESULTS: When employing the conventional method of scoring, the findings indicate that there is no notable disparity between the yield of observed translocations and dicentrics. However, when utilizing the PAINT modified method, a notable discrepancy is observed for higher doses, indicating a relevant difference in the mean number of the two types of aberrations. CONCLUSIONS: The choice of scoring method significantly influences the analysis of radiation-induced aberrations, especially when distinguishing between complex and simple chromosomal formations. Further research and analysis are necessary to gain a deeper understanding of the factors and mechanisms impacting the formation of dicentrics and translocations.

9.
Phys Eng Sci Med ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38954381

ABSTRACT

A fundamental parameter to evaluate the beam delivery precision and stability on a clinical linear accelerator (linac) is the focal spot position (FSP) measured relative to the collimator axis of the radiation head. The aims of this work were to evaluate comprehensive data on FSP acquired on linacs in clinical use and to establish the ability of alternative phantoms to detect effects on patient plan delivery related to FSP. FSP measurements were conducted using a rigid phantom holding two ball-bearings at two different distances from the radiation source. Images of these ball-bearings were acquired using the electronic portal imaging device (EPID) integrated with each linac. Machine QA was assessed using a radiation head-mounted PTW STARCHECK phantom. Patient plan QA was investigated using the SNC ArcCHECK phantom positioned on the treatment couch, irradiated with VMAT plans across a complete 360° gantry rotation and three X-ray energies. This study covered eight Elekta linacs, including those with 6 MV, 18 MV, and 6 MV flattening-filter-free (FFF) beams. The largest range in the FSP was found for 6 MV FFF. The FSP of one linac, retrofitted with 6 MV FFF, displayed substantial differences in FSP compared to 6 MV FFF beams on other linacs, which all had FSP ranges less than 0.50 mm and 0.25 mm in the lateral and longitudinal directions, respectively. The PTW STARCHECK phantom proved effective in characterising the FSP, while the SNC ArcCHECK measurements could not discern FSP-related features. Minor variations in FSP may be attributed to adjustments in linac parameters, component replacements necessary for beam delivery, and the wear and tear of various linac components, including the magnetron and gun filament. Consideration should be given to the ability of any particular phantom to detect a subsequent impact on the accuracy of patient plan delivery.

10.
J Med Ethics ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38955477

ABSTRACT

Patients need to be given the relevant information to be able to give informed consent, which might require the disclosure of a provisional diagnosis. Yet, there is no duty to give information to a patient if that patient is aware that this information exists but chooses not to request it. Diagnostic radiographers and healthcare scientists are often responsible for ensuring that patients have given informed consent for the investigations they undertake, but which were requested by other clinicians. Here we examine if they have a duty to disclose a patient's provisional diagnosis made by a referring clinician if the patient asks for this information as part of the informed consent process to a diagnostic investigation. We first consider aspects of UK law, professional guidance and salient ethical principles, emphasising that while professional codes of practice highlight the need to act in the patient's best interest, they do not require giving patients information they do not require for the examination or have not requested. We then propose that diagnostic radiographers and healthcare scientists placed in such a position use a 'minimally necessary disclosure' framework. This framework fulfils their commitment to their patient and the principle of veracity, while respecting the boundaries of their professional duties. The framework ensures that enough detail is given to the patient for them to be able to give informed consent, while shouldering the diagnostic professional from making a full disclosure, which is the duty of the referring clinician.

11.
Emerg Radiol ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38955874

ABSTRACT

PURPOSE: To evaluate patient and procedure-related factors contributing to the radiation dose, cumulative fluoroscopy time (CFT), and procedural time (PT) of Arterial Embolization (AE) for suspected active bleeding. METHODS: Data on patients who underwent AE for suspected bleeding was retrospectively gathered between January 2019 and April 2022. Data collected included the dependent variables consisting of dose-area product (DAP), CFT, PT, and independent variables consisting of demographic, bleeding-specific, and procedure-specific parameters. All statistical computations were performed in SPSS statistics. The alpha value was set at 0.05. RESULTS: Data from a total of 148 AE were collected with an average patient's age of 61.06 ± 21.57 years. Higher DAP was independently associated with male sex (p < 0.002), age ranges between 46 and 65 years (p = 0.019) and > 66 years (p = 0.027), BMI above 30 (p = 0.016), attending with less than 10 years of experience (p = 0.01), and bleeding in the abdomen and pelvis (p = 0.027). Longer CFT was independently associated with attending with less than 10 years of experience (p < 0.001), having 2 (p = 0.004) or > 3 (p = 0.005) foci of bleed, and age between 46 and 65 years (p = 0.007) and ≥ 66 years (p = 0.017). Longer PT was independently associated with attending with less than 10 years of experience (p < 0.001) and having 2 (p = 0.014) or > 3 (p = 0.005) foci of bleed. CONCLUSION: The interventionist experience influenced radiation dose, CFT and PT. Dose was also affected by patients' sex, age, BMI, as well as bleeding location. CFT was also affected by patients' age, and both CFT and PT were also affected by the number of bleeding foci. These findings highlight the multifaceted factors that affect radiation dose and procedural time, emphasizing the importance of interventionist expertise, patient's age, sex, BMI, location and number of bleeds.

12.
Vet Med Sci ; 10(4): e1497, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38952252

ABSTRACT

BACKGROUND: Annually, a massive amount of broiler litter (BL) is produced in the world, which causes soil and surface water pollution due to its high nitrogen content and microbial count. While ruminants can use this non-protein nitrogen (NPN) source for microbial protein synthesis. This issue becomes more critical when protein sources are unavailable or very expensive. One of the sources of NPN is BL which is produced at a considerable amount in the world yearly. OBJECTIVES: This aim of this research was to conduct a survey of non-thermal technologies such as electrocoagulation (EC), ultraviolet (UV) radiation, and ultrasound (US) waves on the microbial safety and nutritional value of BL samples as a protein source in ruminant diets. MATERIALS AND METHODS: The methodology of this study was based on the use of an EC device with 24 V for 60 min, UV-C light radiation (249 nm) for 1 and 10 min, and US waves with a frequency of 28 kHz for 5, 10 and 15 min to process BL samples compared with shade-dried samples. Chemical composition and nutritional values of processed samples were determined by gas production technique and measurement of fermentation parameters in vitro. RESULTS: Based on the results, microbial safety increased in the samples processed with the US (15 min). The EC method had the best performance in reducing the number of fungi and mould. However, none of the methods could remove total bacteria and fungi. Digestibility of BL was similar in shade-dried, EC, and US (10 min) treatments. In general, the use of EC and US15 without having adverse effects on gas production caused a decrease in the concentration of ammonia nitrogen. In contrast, it caused a decrease in neutral detergent fibre (NDF) in the investigated substrate. CONCLUSIONS: In general, it can be concluded that the use of US5 and EC methods without having a negative effect on the parameters of gas production and fermentation in vitro, while reducing NDF, causes a significant reduction in the microbial load, pathogens, yeast, and mould. Therefore, it is suggested to use these two methods to improve feed digestibility for other protein and feed sources.


Subject(s)
Chickens , Fermentation , Nutritive Value , Ultraviolet Rays , Animals , Ultrasonic Waves , Manure/analysis , Manure/microbiology
13.
Front Oncol ; 14: 1405486, 2024.
Article in English | MEDLINE | ID: mdl-38957315

ABSTRACT

Introduction: Immunotherapy is revolutionizing the management of multiple cancer types. However, only a subset of patients responds to immunotherapy. One mechanism of resistance is the absence of immune infiltrates within the tumor. In situ vaccine with local means of tumor destruction that can induce immunogenic cell death have been shown to enhance tumor T cell infiltration and increase efficacy of immune checkpoint blockade. Methods: Here, we compare three different forms of localize tumor destruction therapies: radiation therapy (RT), vascular targeted photodynamic therapy (VTP) and cryoablation (Cryo), which are known to induce immunogenic cell death, with their ability to induce local and systemic immune responses in a mouse 4T1 breast cancer model. The effects of combining RT, VTP, Cryo with anti-PD1 was also assessed. Results: We observed that RT, VTP and Cryo significantly delayed tumor growth and extended overall survival. In addition, they also induced regression of non-treated distant tumors in a bilateral model suggesting a systemic immune response. Flow cytometry showed that VTP and Cryo are associated with a reduction in CD11b+ myeloid cells (granulocytes, monocytes, and macrophages) in tumor and periphery. An increase in CD8+ T cell infiltration into tumors was observed only in the RT group. VTP and Cryo were associated with an increase in CD4+ and CD8+ cells in the periphery. Conclusion: These data suggest that cell death induced by VTP and Cryo elicit similar immune responses that differ from local RT.

14.
Front Oncol ; 14: 1386058, 2024.
Article in English | MEDLINE | ID: mdl-38957327

ABSTRACT

Introduction: Precise patient positioning with image guidance (IGRT) is essential for safe prostate radiotherapy. We present the first report of utilizing a CT-visible hydrogel spacer, used to decrease rectal radiation dose, as a surrogate fiducial marker to aid in daily IGRT with cone-beam CT (CBCT) in stereotactic radiotherapy (SABR) for prostate cancer. Materials and methods: Prior to CT simulation, patients underwent placement of three intraprostatic gold fiducial markers and radiopaque hydrogel spacer per standard practice. At treatment, after initial setup, a CBCT was acquired and fused to the planning CT based on 3-dimensional matching of the spacer. A second alignment was then performed based on the fiducial markers. The six directional shifts (three linear and three rotational) were recorded, and the differences compared. Results: 140 individual fractions across 41 consecutive patients were evaluated. Mean/median differences between hydrogel spacer-based and fiducial-based alignment in linear (vertical, longitudinal, lateral) and rotational (rotation, pitch, roll) shifts were 0.9/0.6mm, 0.8/0.5mm, and 0.6/0.4mm, and 0.38/0, 0.62/0, and 0.35/0 degrees, respectively. No difference was observed in 9.9%, 22.9%, and 22.14% of linear shifts, and 65.7%, 65%, and 66.4% rotational shifts, respectively. Significantly smaller differences were observed in the latter 70 fractions vs. the former, and results were consistent across evaluators. Conclusions: For precise daily IGRT with CBCT for prostate SABR, alignment using a radiopaque hydrogel spacer was highly comparable to intraprostatic fiducial markers. This represents the first report supporting an additional indication of IGRT for a CT-visible hydrogel spacer, to further enhance treatment accuracy and potentially obviate the need for the additional fiducial marker procedure.

15.
J Radiol Prot ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38959875

ABSTRACT

BACKGROUND: Anecdotal reports are appearing in the scientific literature about cases of brain tumors in interventional physicians who are exposed to ionizing radiation. In response to this alarm, several designs of leaded caps have been made commercially available. However, the results reported on their efficacy are discordant. OBJECTIVE: To synthesise, by means of a systematic review of the literature, the capacity of decreasing radiation levels conferred by radiation attenuating devices (RAD) at the cerebral level of interventional physicians. METHODOLOGY: A systematic review were performed including the following databases: MEDLINE, SCOPUS, EBSCO, Science Direct, Cochrane Controlled Trials Register (CENTRAL), WOS, WHO International Clinical Trials Register, Scielo and Google Scholar, considering original studies that evaluated the efficacy of RAD in experimental or clinical contexts from January 1990 to May 2022. Data selection and extraction were performed in triplicate, with a fourth author resolving discrepancies. RESULTS: Twenty articles were included in the review from a total of 373 studies initially selected from the databases. From these, twelve studies were performed under clinical conditions encompassing 3801 fluoroscopically guided procedures, ten studies were performed under experimental conditions with phantoms, with a total of 88 procedures, four studies were performed using numerical calculations with a total of 63 procedures. The attenuation and effectiveness of provided by the caps analysed in the present review varying from 12.3% to 99.9%, y 4.9% to 91% respectively. CONCLUSION: RAD were found to potentially provide radiation protection, but a high heterogeneity in the shielding afforded was found. This indicates the need for local assessment of cap efficiency according to the practice.

16.
Phys Med Biol ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38959910

ABSTRACT

OBJECTIVE: To develop and benchmark a novel 3D dose verification technique consisting of polymer-gel-dosimeter (PGD) with cone-beam-CT (CBCT) readout through a two-institution study. The technique has potential for wide and robust applicability through reliance on CBCT readout. Approach: Three treatment plans (3-Field, TG119-C-shape spine, 4-target SRS) were created by two independent institutions (Institution A and B). A Varian Truebeam LINAC was used to deliver the plans to NIPAM polymer gel dosimeters produced at both institutions using an identical approach. For readout, a slow CBCT scan mode was used to acquire pre- and post-irradiation images of the gel (1 mm slice thickness). Independent gel analysis tools were used to process the PGD images (A: VistaAce software, B: in-house MATLAB code). Comparing planned and measured doses, the analysis involved a combination of 1D line profiles, 2D contour plots, and 3D global gamma maps (criteria ranging between 2%1mm and 5%2mm, with a 10% dose threshold). Main Results: For all gamma criteria tested, the 3D gamma pass rates were all above 90% for 3-field and 88% for the SRS plan. For the C-shape spine plan, we benchmarked our 2% 2mm result against previously published work using film analysis (93.4%). For 2%2mm, 99.4% (Institution A data), and 89.7% (Institution B data) were obtained based on VistaAce software analysis, 83.7% (Institution A data), and 82.9% (Institution B data) based on MATLAB. Significance: The benchmark data demonstrate that when two institutions follow the same rigorous procedures gamma passing rates up to 99%, for 2%2mm criteria can be achieved for substantively different treatment plans. The use of different software and calibration techniques may have contributed to the variation in the 3D gamma results. By sharing the data across institutions, we observe the gamma passing rate is more consistent within each pipeline, indicating the need for standardized analysis methods.

17.
J Histotechnol ; : 1-7, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38957981

ABSTRACT

H vessels are an essential link in angiogenic-osteogenic coupling and orchestrate the process of bone healing. H vessels are critically deficient in the setting of radiation-induced fractures, which have been reported to occur in up to 25% of patients undergoing radiotherapy. By increasing H-vessel proliferation, Deferoxamine (DFO) revitalizes the physiologic response to skeletal injury and accelerates irradiated fracture repair. H-vessel quantification is therefore an important outcome measure in histologic analysis of bone healing. However, an optimized protocol for staining H vessels in formalin-fixed paraffin-embedded (FFPE) tissue sections has not been reported. With this protocol, we describe a method of staining FFPE bone samples with minimal background fluorescence and high signal-to-noise ratio. We examined mandibular specimens in a rat model of bone healing from a range of fracture conditions, including healthy bone (Fx), irradiated bone (XFx), and irradiated bone with DFO treatment (XFx-DFO). Quantitative analysis revealed a significant increase of H vessels in the XFxDFO group compared to both the Fx and XFx groups. By optimizing immunofluorescent staining of H vessels in FFPE samples across a range of fracture conditions, we offer investigators an efficacious means of producing reliable imaging for quantitative analysis of H vessels in an irradiated fracture callus.

18.
Vestn Oftalmol ; 140(3): 19-26, 2024.
Article in Russian | MEDLINE | ID: mdl-38962975

ABSTRACT

PURPOSE: This study comparatively analyzed the morphology of eye tissues after laser exposure using the latest generation of transscleral laser techniques - micropulse transscleral cyclophotocoagulation (MP-TSCPC) and laser activation of scleral hydropermeability (LASH) - in an anatomical experiment. MATERIAL AND METHODS: The study used pulsed-periodic radiation of an Er-glass fiber laser (λ=1.56 µm) and radiation of a diode laser (λ=0.81 µm) in the micropulse mode. A comparative morphological evaluation of histological preparations of target scleral and ciliary body (CB) tissues was performed with the study of laser-induced changes occurring after LASH and MP-TSCPC. RESULTS: The study of histological preparations obtained after MP-TSCPC and LASH did not reveal any noticeable signs of an inflammatory reaction or significant destructive changes. There were no signs of pronounced coagulative changes in the form of disorganization of connective and muscle tissue in the exposure area. At the same time, MP-TSCPC was accompanied by thinning and discontinuity of the CB pigment epithelium in the projection of its flat part and expansion of the gaps between the anterior connective tissue fibers fixing the CB to the sclera, which is likely a factor contributing to uveoscleral outflow. After LASH, in the irradiated areas at the level of the outer layers of the sclera (¾ of its thickness) located in the projection of the flat part of the ciliary body, multiple slit-like cavities and enlargements (stretching) of interfiber spaces were revealed with simultaneous compaction of the inner part of the sclera (» of its thickness). CONCLUSION: The identified morphological changes may indicate certain differences in the mechanisms of intraocular pressure (IOP) reduction after MP-TSCPC and LASH. The results of this study suggest that the enhancement of uveoscleral outflow of intraocular fluid and the hypotensive effect after MP-TSCPC may be associated with laser-induced expansion of the interspaces between the anterior connective tissue fibers of the CB in the suprachoroidal space. With LASH, the possible mechanism of lowering IOP may be related rather to an increase in transscleral filtration due to the appearance of slit-like interfiber spaces in the sclera, caused by local contraction of scleral fibers in the area of laser exposure. The absence of pronounced destructive changes at the histological level indicates the gentle nature of both laser techniques and the possibility of expanding the indications for the use of LASH in the treatment of glaucoma, including at its earlier stages.


Subject(s)
Ciliary Body , Laser Coagulation , Sclera , Sclera/surgery , Ciliary Body/surgery , Humans , Laser Coagulation/methods , Laser Coagulation/adverse effects , Glaucoma/surgery , Glaucoma/physiopathology , Lasers, Semiconductor/therapeutic use , Lasers, Semiconductor/adverse effects
19.
Int J Biometeorol ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963428

ABSTRACT

The purpose of this study is to understand a physical mechanism to determine the surface temperature of clothes in calm and fine conditions of outdoors. We observed surface temperatures of polo shirts of the same material and design but different colors. The shirts were placed in unshaded and well-ventilated outdoor, open spaces on sunny summer days. The maximum difference between dark green or black and white was more than 15 °C during calm, fine weather and was greatest when the solar radiation was strong. If the transmission of solar radiation energy through a shirt is ignored to calculate the absorption by the shirt, the difference in solar radiation absorption due to different colors is as much as 24% in the maximum, and if considered, we concluded that an absorption difference of 34% led to a temperature difference of 15℃. When we compared the brightness of the colors, we found that the albedo of both the visible and NIR bands explained why the red and green colors were so different with respect to the surface temperatures we observed. The reflection in the NIR bands was also an important determinant of the surface temperature. An additional experiment using masks showed that the temperature difference between white and black was almost eliminated at a wind speed of ~ 3 m/s. The color of clothing is therefore a target for small-scale adaptation to climate change.

20.
Cancer Biol Ther ; 25(1): 2371632, 2024 Dec 31.
Article in English | MEDLINE | ID: mdl-38946404

ABSTRACT

To investigate the impact of the effective radiation dose to immune cells (EDIC) and gross tumor volume (GTV) on lymphopenia and survival in patients with locally advanced esophageal squamous cell carcinoma (LAESCC). Between January 2013 and December 2020, 272 LAESCC patients were treated with definitive radiotherapy in two institutions. Based on radiation doses to the lungs, heart, and body region scanned, EDIC was calculated as an equal uniform dose to the total blood considering blood flow and fraction effect. The radiotherapy plan was used to calculate the GTVs. Lymphopenia was graded based on the lowest lymphocyte count during RT. The overall survival (OS), progress-free survival (PFS), and local recurrence-free survival (LRFS) were analyzed statistically. The lowest lymphocyte count was significantly correlated with EDIC (r= -0.389, p < .001) and GTV (r= -0.211, p < .001). Lymphopenia, EDIC, and GTV are risk factors for patients with ESCC. In a Kaplan-Meier analysis with EDIC and GTV as stratification factors, lymphopenia was not associated with OS in the EDIC>12.9 Gy group (p = .294)and EDIC ≤ 12.9 Gy group, and it was also not associated with OS in GTV>68.8 cm3 group (p = .242) and GTV ≤ 68.8 cm3 group(p = .165). GTV and EDIC had an impact on the relationship between lymphopenia and OS in patients with LAESCC undergoing definitive RT. Poorer OS, PFS, and LRFS are correlated with lymphopenia, higher EDIC, and larger GTV.


Subject(s)
Esophageal Neoplasms , Esophageal Squamous Cell Carcinoma , Lymphopenia , Humans , Lymphopenia/etiology , Esophageal Squamous Cell Carcinoma/pathology , Esophageal Squamous Cell Carcinoma/mortality , Esophageal Squamous Cell Carcinoma/radiotherapy , Male , Female , Middle Aged , Esophageal Neoplasms/mortality , Esophageal Neoplasms/pathology , Esophageal Neoplasms/radiotherapy , Aged , Adult , Retrospective Studies , Prognosis , Aged, 80 and over , Tumor Burden , Lymphocyte Count , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...