Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 486
Filter
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 321: 124719, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38959690

ABSTRACT

Mineral water is a natural water that originated from an underground water table, a well, or a natural spring which is considered microbiologically intact. The revenue from the bottled mineral water industry will be USD 342.40 billion in 2023, and it is expected to grow at a compound annual growth rate (CAGR) of 5.24 %. Consequently, the discrimination of original bottled mineral water from tap water is an important issue that requires designing sensors for simple and portable identification of these two types of water. In this work, we have developed a Dip-Type colorimetric paper-based sensor array with three organic dyes (Bromothymol Blue, Bromophenol Blue, and Methyl Red) followed by chemometrics' pattern recognition methods (PCA and LDA) for discrimination of original bottled mineral waters from tap waters based on differences in ion variety and ion quantity. Forty brands of mineral water and twenty-six Tap water samples from different regions of Shiraz and other Iranian cities were analyzed by this sensor array. Moreover, these experiments were performed in two consecutive years to check the versatility of the sensor with seasonal changes in waters. This sensor array was able to discriminate these two water types from each other with an accuracy of > 95 % based on the analysis of 85 water samples.

2.
Clin Chim Acta ; 561: 119767, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38857671

ABSTRACT

Biosensors are unique analytical tools for the detection of biomarkers. Of these, autoantibodies against citrullinated proteins (ACPA) are useful for the differential diagnosis of rheumatoid arthritis (RA). The autoantibodies may be detected by immunoassay technology using synthetic cyclic citrullinated peptides (CCP), ie, anti-CCP. Recently, several biosensors have been developed for anti-CCP using CCP and mutated citrullinated vimentin (MCV) as recognition elements. In this review we highlight all currently available ACPA biosensor technology including those based on fluorescence, chemiluminescence, electrochemiluminescence (ECL), surface-enhanced Raman scattering (SERS)-based, surface plasmon resonance (SPR), lateral flow immunoassays (LFIA), and electrochemical. We explore various peptides as recognition elements, electrode modifiers and signal amplification systems thus providing new opportunities for next-generation biosensor design in RA.

3.
Med Microbiol Immunol ; 213(1): 10, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38907945

ABSTRACT

Rapid tests allow outpatient, low cost, reliable, screening for chronic HIV infection. However, data regarding their sensitivity on primary infection remain scarce. The objective of this study was to assess sensitivity of nine HIV rapid tests for primary HIV-1 infection screening. Seventy-five serum samples from patients during HIV-1 primary infection were included. Primary infection was diagnosed by a positive 4th generation ELISA and HIV-1 RNA positivity confirmed by Western blot patterns associated with HIV-1 primary infection. Early seroconversion was defined as the absence of antibodies on HIV-1 Western blot associated with HIV-1 RNA and p24-antigen positivity. An identical sensitivity (95% CI) of 76.7% (65.2-84.2%) was observed for HIV 1/2 STAT-PAK® Assay (STAT-PAK), INSTI™ HIV-1/HIV-2 antibody Test (INSTI), SURE CHECK® HIV 1/2 (SURE CHECK) and MULTISURE HIV rapid test (MULTISURE) with visual reading. Sensitivity was 74.7% (63.8-83.1%) for MULTISURE (automatic reading), 77.0% (66.3-85.1%) for FIRST RESPONSE® Test VIH 1-2.O CARTE (FIRST RESPONSE), 83.8% (73.8-90.5%) for VIKIA HIV1/2® (VIKIA), 88.0% (78.7-93.6%) for Genie™ Fast HIV 1/2 (Genie Fast), 88.6% (79.0-94.1%) for Hexagon HIV (Hexagon), and 92.8% (83.6-96.3%) for Exacto® TEST HIV Pro (Exacto). However, rapid tests performed poorly for the early seroconversion subgroup (n = 14), with sensitivities ranging from 7% (1.3-31.5%) for STAT-PAK, INSTI, SURE CHECK, MULTISURE (automatic reading), to 29% (12-55%) for FIRST RESPONSE, 31% (13-58%) for VIKIA, 43% (21-67%) for Hexagon and 57.1% (32.6-78.6%) for Exacto and Genie Fast. Overall, despite significant discrepancies in sensitivity, HIV rapid tests should be used with caution in the context of a suspected primary infection.


Subject(s)
HIV Antibodies , HIV Infections , HIV-1 , Mass Screening , Sensitivity and Specificity , Humans , HIV Infections/diagnosis , HIV-1/immunology , HIV-1/isolation & purification , Male , Mass Screening/methods , Female , Adult , HIV Antibodies/blood , Middle Aged , RNA, Viral/blood , Enzyme-Linked Immunosorbent Assay/methods , Young Adult , Blotting, Western/methods , Diagnostic Tests, Routine/methods , HIV Testing/methods
4.
Biotechnol J ; 19(6): e2400040, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38863123

ABSTRACT

IMP (inosinic acid) is a crucial intermediate in the purine metabolic pathway and is continuously synthesized in all cells. Besides its role as a precursor for DNA and RNA, IMP also plays a critical or essential role in cell growth, energy storage, conversion, and metabolism. In our study, we utilized the circularly permuted fluorescent protein (cpFP) and IMP dehydrogenase to screen and develop the IMP biosensor, IMPCP1. By introducing a mutation in the catalytically active site of IMPCP1, from Cys to Ala, we disrupted its ability to catalyze IMP while retaining its capability to bind to IMP without affecting the IMP concentration in the sample. To immobilize IMPCP1, we employed the SpyCatcher/SpyTag system and securely attached it to Magarose-Epoxy, resulting in the development of the IMP rapid test kit, referred to as IMPTK. The biosensor integrated into IMPTK offers enhanced stability, resistance to degradation activity, and specific recognition of IMP. It is also resistant to peroxides and temperature changes. IMPTK serves as a rapid and stable assay for analyzing IMP concentrations in fermentation broth. Within the linear range of IMP concentrations, it can be utilized as a substitute for HPLC. The IMPTK biosensor provides a reliable and efficient alternative for monitoring IMP levels, offering advantages such as speed, stability, and resistance to environmental factors.


Subject(s)
Biosensing Techniques , Fermentation , Biosensing Techniques/methods , Escherichia coli/genetics , Escherichia coli/metabolism
5.
J Infect Chemother ; 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38697390

ABSTRACT

OBJECTIVES: An increasing number of drug-resistant bacteria have been identified recently. In particular, drug-resistant bacteria have been linked to unfavorable prognoses in patients with bacteremia, highlighting the need for rapid testing. Our previous studies have focused on the utility of a drug susceptibility testing microfluidic (DSTM) method using microfluidic channels. A system with this DSTM method for screening for ß-lactamases can rapidly detect extended-spectrum ß-lactamases (ESBLs) and metallo-ß-lactamases (MBLs). In this study, we have evaluated the clinical utility of pre-treatment for screening positive blood cultures using the DSTM method. METHODS: A total of 178 positive blood cultures and five simulated samples of MBL-producing bacteria were prepared at Kochi University Hospital, Japan. The pretreatment consisted of a two-step centrifugation. The obtained sediments were screened with the DSTM method for the production of ß-lactamase based on morphological changes in the bacteria after 3 h of incubation. RESULTS: The pretreatment functioned properly for all samples. Of the 25 ESBL samples, 21 were positive for ESBLs. Four false-negative samples, all obtained from the same patient, contained CTX-M-2 enzyme-producing Proteus mirabilis and showed insusceptibility to an ESBL inhibitor. The simulated samples prepared for MBL screening were positive for MBLs. CONCLUSIONS: When combined with a method for rapidly identifying bacterial species, DSTM may enable patients with bloodstream infections to start receiving appropriate treatment within 4 h after positive blood cultures are screened.

6.
Viruses ; 16(5)2024 04 23.
Article in English | MEDLINE | ID: mdl-38793539

ABSTRACT

With the continuous spread of new SARS-CoV-2 variants of concern (VOCs), the monitoring of diagnostic test performances is mandatory. We evaluated the changes in antigen diagnostic tests' (ADTs) accuracy along the Delta to Omicron VOCs transition, exploring the N protein mutations possibly affecting ADT sensitivity and assessing the best sampling site for the diagnosis of Omicron infections. In total, 5175 subjects were enrolled from 1 October 2021 to 15 July 2022. The inclusion criteria were SARS-CoV-2 ADT combined with a same-day RT-PCR swab test. For the sampling site analysis, 61 patients were prospectively recruited during the Omicron period for nasal and oral swab analyses by RT-PCR. Next-Generation Sequencing data were obtained to evaluate the different sublineages. Using RT-PCR as a reference, 387 subjects resulted in becoming infected and the overall sensitivity of the ADT decreased from 63% in the Delta period to 33% in the Omicron period. This decrease was highly statistically significant (p < 0.001), and no decrease in viral load was detected at the RNA level. The nasal site presented a significantly higher viral load than the oral site during the Omicron wave. The reduced detection rate of Omicron infections by ADT should be considered in the global testing strategy to preserve accurate diagnoses across the changing SARS-CoV-2 variants.


Subject(s)
COVID-19 , SARS-CoV-2 , Sensitivity and Specificity , Humans , SARS-CoV-2/immunology , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19/virology , COVID-19/immunology , Male , Viral Load , Female , Antigens, Viral/immunology , COVID-19 Serological Testing/methods , Mutation , Middle Aged , Adult , Prospective Studies , RNA, Viral/genetics , Aged
7.
Heliyon ; 10(9): e29938, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38707409

ABSTRACT

Lateral flow immunoassays (LFIA) for antibody detection represent cost-effective and user-friendly tools for serology assessment. This study evaluated a new LFIA prototype developed with a recombinant chimeric antigen from the spike/S and nucleocapsid/N proteins to detect anti-SARS-CoV-2 IgG antibodies. The evaluation of LFIA sensitivity and specificity used 811 serum samples from 349 hospitalized, SARS-CoV-2 RT-qPCR positive COVID-19 patients, collected at different time points and 193 serum samples from healthy controls. The agreement between ELISA results with the S/N chimeric antigen and LFIA results was calculated. The LFIA prototype for SARS-CoV-2 using the chimeric S/N protein demonstrated 85 % sensitivity on the first week post symptoms onset, reaching 94 % in samples collected at the fourth week of disease. The agreement between LFIA and ELISA with the same antigen was 92.7 %, 0.827 kappa Cohen value (95 % CI [0.765-0.889]). Further improvements are needed to standardize the prototype for whole blood use. The inclusion of the novel chimeric S + N antigen in the COVID-19 IgG antibody LFIA demonstrated optimal agreement with results from a comparable ELISA, highlighting the prototype's potential for accurate large-scale serologic assessments in the field in a rapid and user-friendly format.

8.
J Infect Public Health ; 17(6): 1065-1078, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38705059

ABSTRACT

We meta-analyzed the diagnostic accuracy of rapid diagnostic tests (dipsticks) and loop-mediated isothermal amplification (LAMP) method to detect Shigella species. We searched MEDLINE, Embase, Web of Science and Google Scholar from inception to 2023 for studies reporting on the performance of Shigella dipstick and LAMP tests compared with culture or polymerase chain reaction (PCR). Our search identified 2618 studies, of which fourteen met the inclusion criteria for the systematic review. Ten studies covering 4056 tests (from twelve countries) were included in the meta-analysis. The overall pooled sensitivity and specificity were 98% (95% CI: 94-100) and 97% (95% CI: 92-99), respectively. Pooled sensitivity and specificity of dipsticks were 95% and 98%, respectively. In contrast, LAMP showed higher pooled sensitivity (100%) and diagnostic odds ratio (431752), but similar specificity (97%). LAMP and dipstick tests exhibited promising performance, suggesting that they could be useful for assisting in the diagnosis of shigellosis.


Subject(s)
Dysentery, Bacillary , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , Sensitivity and Specificity , Shigella , Humans , Nucleic Acid Amplification Techniques/methods , Shigella/isolation & purification , Shigella/genetics , Dysentery, Bacillary/diagnosis , Dysentery, Bacillary/microbiology , Molecular Diagnostic Techniques/methods , Diagnostic Tests, Routine/methods , Rapid Diagnostic Tests
9.
Rev. clín. esp. (Ed. impr.) ; 224(4): 197-203, Abr. 2024. tab
Article in Spanish | IBECS | ID: ibc-232254

ABSTRACT

Fundamento: Estudiar la prevalencia de anticuerpos neutralizantes en el personal sanitario y de apoyo tras la administración de la segunda dosis de vacuna BNT162b2 (Pfizer–BioNTech). Material y métodos: En diciembre 2021 llevamos a cabo un estudio en el Departamento de Salud de Orihuela, Alicante (España), formado por 1.500 trabajadores. En los participantes del estudio, recogimos variables demográficas y realizamos un test «point-of-care» (POC) de inmunocromatografía para medir la presencia de anticuerpos neutralizantes (OJABIO® SARS-CoV-2 Neutralizing Antibody Detection Kit, fabricado por Wenzhou OJA Biotechnology Co., Ltd.- Wenzhou, Zhejiang, China) antes de la administración de la tercera dosis de vacuna. Resultados: Obtuvimos información completa de 964 (64%) trabajadores, siendo 290 varones y 674 mujeres. La edad media fue de 45,8 años (mín: 18, máx: 68) y el tiempo desde la última dosis (TUD) de vacuna fue 40,5 semanas (mín: 1,71; máx: 47,71). Un total de 131 (13,5%) habían padecido infección por SARS-CoV-2 confirmada mediante RT-PCR. La proporción de sujetos con presencia de anticuerpos neutralizantes fue de 38,5%. En el análisis multivariable el TUD de vacuna (razón de probabilidades ajustada [ORa] semana: 1,07; IC 95%: 1,04; 1,09) y la infección previa por SARS-CoV-2 (ORa: 3,7; IC 95%: 2,39; 5,63) mostraron asociación estadísticamente significativa con la presencia de anticuerpos neutralizantes. Conclusiones: El TUD de vacuna y la infección previa por SARS-CoV-2 determinaron la presencia de anticuerpos neutralizantes en 38,5% del personal sanitario y personal de apoyo.(AU)


Aim: To study the prevalence of neutralizing antibodies in healthcare workers and healthcare support personnel after the administration of the second dose of the BNT162b2 vaccine (Pfizer-BioNTech). Materials and methods: In December 2021, we undertook a study in the Health Department in Orihuela, Alicante (Spain), which consists of 1500 workers. We collected demographic variables about the study participants, and we performed a «point-of-care» immunochromatography test to measure the presence of neutralizing antibodies (OJABIO® SARS-CoV-2 Neutralizing Antibody Detection Kit, manufactured by Wenzhou OJA Biotechnology Co., Ltd. Wenzhou, Zhejiang, China) before the administration of the third dose of the vaccine. Results: We obtained complete information about 964 (64%) workers, which consisted of 290 men and 674 women. The average age was 45,8 years (min. 18, max. 68) and the average time since the last dose of the vaccine was 40,5 weeks (min. 1,71, max. 47,71). A total of 131 participants (13,5%) had suffered infection by SARS-CoV-2 confirmed using RT-PCR. The proportion of participants who showed presence of neutralizing antibodies was 38,5%. In the multivariable analysis, the time since the last dose of the vaccine (aOR week: 1,07; 95%CI: 1,04; 1,09) and previous infection by SARS-CoV-2 (aOR: 3,7; 95CI: 2,39; 5,63) showed a statistically significant association with the presence of neutralizing antibodies. Conclusions: The time since the administration of the last dose of the vaccine and the previous infection by SARS-CoV-2 determined the presence of neutralizing antibodies in 38,5% of the healthcare workers and support workers.(AU)


Subject(s)
Humans , Male , Female , Health Personnel , Antibodies, Neutralizing , Prevalence , /immunology , Spain , /epidemiology
10.
Malar J ; 23(1): 104, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38609964

ABSTRACT

BACKGROUND: While Plasmodium falciparum and Plasmodium vivax cause the majority of malaria cases and deaths, infection by Plasmodium malariae and other Plasmodium species also causes morbidity and mortality. Current understanding of these infections is limited in part by existing point-of-care diagnostics that fail to differentiate them and have poor sensitivity for low-density infections. Accurate diagnosis currently requires molecular assays performed in well-resourced laboratories. This report describes the development of a P. malariae diagnostic assay that uses rapid, isothermal recombinase polymerase amplification (RPA) and lateral-flow-strip detection. METHODS: Multiple combinations of custom RPA primers and probes were designed using publicly available P. malariae genomic sequences, and by modifying published primer sets. Based on manufacturer RPA reaction conditions (TwistDx nfo kit), an isothermal assay was optimized targeting the multicopy P. malariae 18S rRNA gene with 39 °C incubation and 30-min run time. RPA product was visualized using lateral strips (FAM-labeled, biotinylated amplicon detected by a sandwich immunoassay, visualized using gold nanoparticles). Analytical sensitivity was evaluated using 18S rRNA plasmid DNA, and clinical sensitivity determined using qPCR-confirmed samples collected from Tanzania, Ethiopia, and the Democratic Republic of the Congo. RESULTS: Using 18S rRNA plasmid DNA, the assay demonstrates a detection limit of 10 copies/µL (~ 1.7 genome equivalents) and 100% analytical specificity. Testing in field samples showed 95% clinical sensitivity and 88% specificity compared to qPCR. Total assay time was less than 40 min. CONCLUSION: Combined with simplified DNA extraction methods, the assay has potential for future field-deployable, point-of-care use to detect P. malariae infection, which remains largely undiagnosed but a neglected cause of chronic malaria. The assay provides a rapid, simple readout on a lateral flow strip without the need for expensive laboratory equipment.


Subject(s)
Gold , Metal Nanoparticles , RNA, Ribosomal, 18S/genetics , Biological Assay , DNA
11.
Eur J Obstet Gynecol Reprod Biol ; 297: 65-71, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38581887

ABSTRACT

OBJECTIVE: We aimed to determine whether the semi-quantitative metalloproteinase-8 (MMP-8) bedside test is a worthwhile indicator in reflecting the severity of of intra-amniotic inflammation (IAI) and in predicting adverse pregnancy outcomes. STUDY DESIGN: This retrospective cohort study comprised 76 singleton-pregnant women admitted to the Seoul National University Bundang Hospital with a diagnosis of preterm premature rupture of membranes (preterm PROM) between 20 weeks 0 days and 33 weeks 6 days of gestation who underwent trans-abdominal amniocentesis to confirm intra-amniotic infection by positive results for aerobic/anaerobic bacteria, fungi, and genital mycoplasma and evaluate lung maturity. The semi-quantitative MMP-8 rapid test kit employs a colourimetric assay to quantify MMP-8 levels in amniotic fluid (AF), expressing results from 0 to 100 percent. Participants were divided into three groups: group 1, including negative MMP-8 test with colour scale of 0 % (negative, n = 17); group 2, including positive MMP-8 test with colour scale < 51 % (weak positive, n = 21); and group 3, including positive MMP-8 test with colour scale of 51 %-100 % (strong positive, n = 38). RESULTS: Approximately 78 % (59/76) of the participants showed a positive MMP-8 test result; all culture-proven AF samples (33.3 % [25/75]) yielded positive MMP-8 test, categorizing these patients into either group 2 or group 3. A significant trend was observed where the rate of positive culture-proven samples increased with the progression from group 1 (negative) to group 3 (strong positive). Both white blood cell counts in AF and maternal serum C-reactive protein levels were found to escalate with the progression of test results from negative to strong positive. This progression was associated with an increased risk of spontaneous preterm birth within 48 h, 7 days, and 14 days from amniocentesis and within 34 weeks of gestation. CONCLUSION: The more the test results progress from negative to strong positive, the shorter the interval from amniocentesis to delivery becomes, and the higher the risk of intra-amniotic infection, spontaneous preterm delivery, and other perinatal complications. This relationship highlights the critical value of the semi-quantitative MMP-8 rapid test in predicting adverse pregnancy outcomes in patients with preterm PROM.


Subject(s)
Amniotic Fluid , Fetal Membranes, Premature Rupture , Matrix Metalloproteinase 8 , Humans , Female , Pregnancy , Fetal Membranes, Premature Rupture/diagnosis , Matrix Metalloproteinase 8/analysis , Matrix Metalloproteinase 8/metabolism , Retrospective Studies , Adult , Amniotic Fluid/microbiology , Pregnancy Outcome , Chorioamnionitis/diagnosis , Amniocentesis , Predictive Value of Tests , Biomarkers/analysis , Premature Birth/diagnosis
12.
Vaccines (Basel) ; 12(3)2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38543941

ABSTRACT

African swine fever (ASF) is a contagious disease of wild boar and domestic pigs notifiable to the World Organisation for Animal Health due to its high socio-economic impact. ASF is caused by the complex ASF virus (ASFV), and it can present different clinical manifestations that can be confused with other diseases; for this reason, laboratory testing is necessary for the proper diagnosis of clinically suspected animals. Despite the efforts put into it over decades, no treatment or safe vaccine is globally available, and disease control is based on early diagnosis and the implementation of strict biosecurity measures. In this context, rapid tests have the potential to accelerate and facilitate the identification of infected animals by giving fast on-site results. In this work, we improved the available point-of-care assays for the diagnosis of the disease by the development of a more specific antigen test and a more sensitive antibody test. This antibody detection test allowed for the earlier detection of infected animals than two commercial indirect ELISAs (statistically significant). Moreover, we developed a combined dual rapid test, unifying, in the same cassette, an antigen detection strip and an antibody detection strip. In this study, we confirmed that this combo approach is a useful tool for implementing rapid tests in the field since it increases the percentage of positive samples detected, even when PCR turns negative, while maintaining a good specificity.

13.
Sci Rep ; 14(1): 7319, 2024 03 27.
Article in English | MEDLINE | ID: mdl-38538635

ABSTRACT

Compared to other infectious diseases, for which LFT development can take years, SARS-CoV-2 antigen LFTS were developed and deployed within months. LFTS for antigen detection were adopted on an unprecedented scale during the COVID-19 pandemic, but many of them lack the sensitivity especially for samples with low viral load. In our previous work, we developed an enhanced signal strip for detection of SARS CoV-2 SI antigens in saliva. Here we introduce some modification to improve the sensitivity, and specificity, and to lower the cost of the strip, by using biotin streptavidin (BS) system. In the modified BS strip, gold-streptavidin and biotinylated Nanobodies (Nbs) against S1 antigen were externally mixed with the tested samples (saliva or nasopharyngeal swab) before their application on the sample pad of the test strip containing angiotensin converting enzyme (ACE-2), as the capturing probe. The study included 320 individuals, with 180 being positively confirmed by RT-PCR and 140 confirmed negative, as well as, 45 health care workers, who were responsible for screening and handling of surgical cases in General Surgery Department and COVID clinic of TBRI. Our results proved that modified BS strip improved the overall sensitivity and specificity of S1antigen detection in saliva samples (95.21% and 99.29% respectively) compared to our previously developed enhanced LFTS (91.66% and 98.57% respectively). Also, the sensitivity of cases with Ct ≤ 30, Ct ≤ 35, and Ct ≤ 40 using the modified BS strip showed higher values (98.54%, 95.38%, and 88.89% respectively), compared to the corresponding results of our previously developed enhanced LFTS (95.86%, 92.31%, and 82.22% respectively). There were no cross-reactions with either Middle East respiratory syndrome corona virus MERS-CoV or SARS-CoV antigens. Furthermore, we found that the lower viral detection limit (LVD) of BS strip was obviously lower than our previous LVD limit of the enhanced LFTS (0.2 × 104 copies/ml vs. 0.4 × 104 copies/ml, respectively). Our developed BS strip showed that saliva samples gave better results than nasopharyngeal swabs of the same patients. The fact of using smaller amounts of Nbs, and ACE2, as well as the dispensing off of conjugate pad when applying BS strip modifications, justified the expected reduction in the costs of the strip. The implementation of BS strips on saliva samples of 45 health co-workers, who were tested 4 and 6 days after exposure to infection, showed an increase in the sensitivity, starting from the 4th day and reaching its highest level on the 6th day in both high risk and paramedic groups (90.9%, and 80.0%, respectively). This study provides evidence that employment of the modified BS system could increase the sensitivity of the strips, lower their cost, and render them an effective screening tool for early detection of the virus in saliva of suspected Covid-19 patients.


Subject(s)
Biotin , COVID-19 , Neoplasm Proteins , Humans , Streptavidin , SARS-CoV-2 , Pandemics , Saliva , COVID-19/diagnosis , Antigens, Viral , Nasopharynx , Specimen Handling
14.
Biosensors (Basel) ; 14(2)2024 Feb 02.
Article in English | MEDLINE | ID: mdl-38392001

ABSTRACT

Tuna is an excellent food product, relatively low in calories, that is recommended for a balanced diet. The continuously increasing demand, especially for bluefin-tuna-based food preparations, and its relatively high market price make adulteration by intentionally mixing with other lower-priced tunas more prospective. The development of rapid methods to detect tuna adulteration is a great challenge in food analytical science. We have thus developed a simple, fast, and low-cost molecular rapid test for the visual detection of tuna adulteration. It is the first sensor developed for tuna authenticity testing. The three species studied were Thunnus thynnus (BFT), Thunnus albacares, and Katsuwonus pelamis. DNA was isolated from fresh and heat-treated cooked fish samples followed by PCR. The PCR products were hybridized (10 min) to specific probes and applied to the rapid sensing device. The signal was observed visually in 10-15 min using gold nanoparticle reporters. The method was evaluated employing binary mixtures of PCR products from fresh tissues and mixtures of DNA isolates from heat-treated tissues (canned products) at adulteration percentages of 1-100%. The results showed that the method was reproducible and specific for each tuna species. As low as 1% of tuna adulteration was detected with the naked eye.


Subject(s)
Metal Nanoparticles , Tuna , Animals , Tuna/genetics , Gold , Prospective Studies , DNA
15.
Molecules ; 29(3)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38338421

ABSTRACT

Food and fish adulteration is a major public concern worldwide. Apart from economic fraud, health issues are in the forefront mainly due to severe allergies. Sardines are one of the most vulnerable-to-adulteration fish species due to their high nutritional value. Adulteration comprises the substitution of one fish species with similar species of lower nutritional value and lower cost. The detection of adulteration, especially in processed fish products, is very challenging because the morphological characteristics of the tissues change, making identification by the naked eye very difficult. Therefore, new analytical methods and (bio)sensors that provide fast analysis with high specificity, especially between closely related fish species, are in high demand. DNA-based methods are considered as important analytical tools for food adulteration detection. In this context, we report the first DNA sensors for sardine species identification. The sensing principle involves species recognition, via short hybridization of PCR-amplified sequences with specific probes, capture in the test zone of the sensor, and detection by the naked eye using gold nanoparticles as reporters; thus, avoiding the need for expensive instruments. As low as 5% adulteration of Sardina pilchardus with Sardinella aurita was detected with high reproducibility in the processed mixtures simulating canned fish products.


Subject(s)
Gold , Metal Nanoparticles , Animals , Reproducibility of Results , DNA/genetics , Fish Products
16.
Rev Clin Esp (Barc) ; 224(4): 197-203, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38423384

ABSTRACT

AIM: To study the prevalence of neutralizing antibodies in healthcare workers and healthcare support personnel after the administration of the second dose of the BNT162b2 vaccine (Pfizer-BioNTech). MATERIALS AND METHODS: In December 2021, we undertook a study in the Health Department in Orihuela, Alicante (Spain), which consists of 1500 workers. We collected demographic variables about the study participants, and we performed a "point-of-care" immunochromatography test to measure the presence of neutralizing antibodies (OJABIO® SARS-CoV-2 Neutralizing Antibody Detection Kit, manufactured by Wenzhou OJA Biotechnology Co., Ltd. Wenzhou, Zhejiang, China) before the administration of the third dose of the vaccine. RESULTS: We obtained complete information about 964 (64%) workers, which consisted of 290 men and 674 women. The average age was 45,8 years (min. 18, max. 68) and the average time since the last dose of the vaccine was 40,5 weeks (min. 1,71, max. 47,71). A total of 131 participants (13,5%) had suffered infection by SARS-CoV-2 confirmed using RT-PCR. The proportion of participants who showed presence of neutralizing antibodies was 38,5%. In the multivariable analysis, the time since the last dose of the vaccine (aOR week: 1,07; 95%CI: 1,04; 1,09) and previous infection by SARS-CoV-2 (aOR: 3,7; 95CI: 2,39; 5,63) showed a statistically significant association with the presence of neutralizing antibodies. CONCLUSIONS: The time since the administration of the last dose of the vaccine and the previous infection by SARS-CoV-2 determined the presence of neutralizing antibodies in 38,5% of the healthcare workers and support workers.


Subject(s)
COVID-19 , Vaccines , Male , Humans , Female , SARS-CoV-2 , Prevalence , Spain/epidemiology , BNT162 Vaccine , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/prevention & control , Health Personnel , Antibodies, Neutralizing , Serologic Tests , COVID-19 Testing
17.
J Clin Microbiol ; 62(3): e0113623, 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38319119

ABSTRACT

Antimicrobial resistance (AMR) is one of the major public health problems worldwide. Multiple strategies have been put in place to address this problem. One of them is the rapid detection of the mechanisms of resistance, such as extended-spectrum beta-lactamases (ESBLs) and/or carbapenemases. We conducted a multicenter study that included nine European centers for the assessment of prototypes of a novel lateral flow immunoassay-based device (BL-DetecTool) for a rapid detection of ESBL (NG-Test CTX-M-MULTI DetecTool) and/or carbapenemases (NG-Test CARBA 5 DetecTool) from Enterobacterales and Pseudomonas aeruginosa in positive urine, positive blood cultures, and rectal swabs. We performed a prospective analysis between January 2021 and June 2022, including overall 22,010 samples. Based on each hospital information, the sensitivity to detect CTX-M was 84%-100%, 90.9%-100%, and 75%-100% for urine, positive blood cultures, and enriched rectal swabs, respectively. On the other hand, the sensitivity to detect carbapenemases was 42.8%-100%, 75%-100%, and 66.6%-100% for urine, positive blood cultures, and enriched rectal swab, respectively. BL-DetecTool allows a rapid and reliable detection of ESBL and carbapenemases directly from urine, positive blood cultures, or enriched rectal swabs, being an easy technique to implement in the workflow of clinical microbiology laboratories. IMPORTANCE: The assessed rapid assay to detect CTX-M beta-lactamases and carbapenemases directly from clinical samples can favor in the rapid detection of these mechanisms of resistance and hence the administration of a more adequate antimicrobial treatment.


Subject(s)
Anti-Infective Agents , beta-Lactamases , Humans , beta-Lactamases/analysis , Bacterial Proteins , Microbial Sensitivity Tests , Anti-Bacterial Agents
18.
J Microbiol Methods ; 219: 106897, 2024 04.
Article in English | MEDLINE | ID: mdl-38342249

ABSTRACT

Salmonella is as an intracellular bacterium, causing many human fatalities when the host-specific serotypes reach the host gastrointestinal tract. Nontyphoidal Salmonella are responsible for numerous foodborne outbreaks and product recalls worldwide whereas typhoidal Salmonella are responsible for Typhoid fever cases in developing countries. Yet, Salmonella-related foodborne disease outbreaks through its food and water contaminations have urged the advancement of rapid and sensitive Salmonella-detecting methods for public health protection. While conventional detection methods are time-consuming and ineffective for monitoring foodstuffs with short shelf lives, advances in microbiology, molecular biology and biosensor methods have hastened the detection. Here, the review discusses Salmonella pathogenic mechanisms and its detection technology advancements (fundamental concepts, features, implementations, efficiency, benefits, limitations and prospects). The time-efficiency of each rapid test method is discussed in relation to their limit of detections (LODs) and time required from sample enrichment to final data analysis. Importantly, the matrix effects (LODs and sample enrichments) were compared within the methods to potentially speculate Salmonella detection from environmental, clinical or food matrices using certain techniques. Although biotechnological advancements have led to various time-efficient Salmonella-detecting techniques, one should consider the usage of sophisticated equipment to run the analysis by moderately to highly trained personnel. Ultimately, a fast, accurate Salmonella screening that is readily executed by untrained personnels from various matrices, is desired for public health procurement.


Subject(s)
Biosensing Techniques , Foodborne Diseases , Humans , Food Microbiology , Salmonella , Foodborne Diseases/microbiology , Food , Biosensing Techniques/methods
19.
Microbiol Spectr ; 12(2): e0325323, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38189332

ABSTRACT

Rapid HIV tests are critical to HIV surveillance and universal testing and treatment programs. We assessed longitudinal patterns in indeterminate HIV rapid test results in an African population-based cohort. Prospective HIV rapid antibody test results, defined by two parallel rapid tests, among participants aged 15-49 years from three survey rounds of the Rakai Community Cohort Study, Uganda, from 2013 to 2018, were assessed. An indeterminate result was defined as any weak positive result or when one test was negative and the other was positive. A total of 31,405 participants contributed 54,459 person-visits, with 15,713 participants contributing multiple visits and 7,351 participants contributing 3 visits. The prevalence of indeterminate results was 2.7% (1,490/54,469). Of the participants with multiple visits who initially tested indeterminate (n = 591), 40.4% were negative, 18.6% were positive, and 41.0% were indeterminate at the subsequent visit. Of the participants with two consecutive indeterminate results who had a third visit (n = 67), 20.9% were negative, 9.0% were positive, and 70.2% remained indeterminate. Compared to a prior negative result, a prior indeterminate result was strongly associated with a subsequent indeterminate result [adjusted prevalence ratio, 23.0 (95% CI = 20.0-26.5)]. Compared to men, women were more likely to test indeterminate than negative [adjusted odds ratio, 2.3 (95% CI = 2.0-2.6)]. Indeterminate rapid HIV test results are highly correlated within an individual and 0.6% of the population persistently tested indeterminate over the study period. A substantial fraction of people with an indeterminate result subsequently tested HIV positive at the next visit, underscoring the importance of follow-up HIV testing protocols.IMPORTANCERapid HIV tests are a critical tool for expanding HIV testing and treatment to end the HIV epidemic. The interpretation and management of indeterminate rapid HIV test results pose a unique challenge for connecting all people living with HIV to the necessary care and treatment. Indeterminate rapid HIV test results are characterized by any weak positive result or discordant results (when one test is negative and the other is positive). We systematically tested all participants of a Ugandan population-based, longitudinal cohort study regardless of prior test results or HIV status to quantify longitudinal patterns in rapid HIV test results. We found that a substantial fraction (>15%) of participants with indeterminate rapid test results subsequently tested positive upon follow-up testing at the next visit. Our findings demonstrate the importance of follow-up HIV testing protocols for indeterminate rapid HIV test results.


Subject(s)
HIV Infections , Male , Humans , Female , Cohort Studies , Prospective Studies , HIV Infections/epidemiology , Longitudinal Studies , Uganda/epidemiology , HIV Testing
20.
Trans R Soc Trop Med Hyg ; 118(2): 127-135, 2024 02 01.
Article in English | MEDLINE | ID: mdl-37818849

ABSTRACT

BACKGROUND: Human immunodeficiency virus (HIV) rapid diagnostic tests (RDTs) are widely used. However, buffer stockouts commonly lead to utilising non-approved liquids, resulting in errors. Our aim was to evaluate the diagnostic accuracy of an alternative buffer. METHODS: Paired Determine HIV-1/2 rapid tests with commercial buffer and locally produced 0.01M phosphate-buffered saline (PBS) were performed on consecutive consenting individuals requiring HIV testing. Serum samples were sent for confirmation through the local gold-standard algorithm (Murex HIV Ag/Ab, Hexagon HIV with/without Geenius HIV 1/2). Test accuracy, κ and exact McNemar's test were also carried out. RESULTS: Of 167 participants, 137 had confirmatory testing. The sensitivity of the Determine HIV-1/2 test using PBS compared with the gold standard was 100% (95% confidence interval [CI] 90.5 to 100) with a specificity of 98% (95% CI 92.9 to 99.8). The κ value was 0.94 compared with the gold standard and 0.92 compared with the Determine HIV-1/2 test using the commercial buffer. McNemar's test showed no evidence of differing sensitivities. Due to operational constraints, the study included 37 of the 49 positive cases as determined by the sample size calculation, resulting in an attained power of 80% instead of the intended 90%. CONCLUSIONS: These results suggest that 0.01M PBS is an alternative solution for Determine HIV-1/2 when buffer stockouts occur.


Subject(s)
Biomedical Research , HIV Infections , HIV-1 , Humans , HIV Infections/diagnosis , HIV Antibodies , Gambia , HIV Testing , Sensitivity and Specificity , HIV-2 , Phosphates
SELECTION OF CITATIONS
SEARCH DETAIL
...