Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Publication year range
1.
Arq. bras. oftalmol ; 81(3): 232-238, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-950448

ABSTRACT

ABSTRACT Purpose: To conduct a 10-year follow-up on the surgical correction of large-angle esotropia using monocular surgery, verifying surgical stability over time in both adults and children, and investigating the presence of consecutive exotropia among reviewed patients. Methods: The angles of deviation in primary position were measured using prism cover testing in patients with good vision in both eyes and the Krimsky method in those with severe amblyopia. Among the 46 patients who underwent surgery, 40 were evaluated 10 years post-surgery. Student's t-test and McNemar's test were used for statistical analyses. Results: No significant differences in the angles of deviation in primary position were found between measurements taken 6 months and 10 years post-surgery (p=0.922), as well as between children and adults (p=0.767). Among the 40 reviewed patients, only five presented with exotropia, all of which were small (the largest being XT 15Δ). Therefore, large consecutive exotropia over time was not observed. Conclusion: Our results suggest that monocular surgery to correct large-angle esotropia using large medial rectus recessions and broad lateral rectus resections was viable and safe in both adults and children over short and long terms.


RESUMO Objetivo: Conduzir um acompanhamento de 10 anos de correção cirúrgica de esotropias de grande ângulo com cirurgia monocular, verificando a estabilidade cirúrgica ao longo do tempo em adultos e crianças, investigando a presença de exotropias consecutivas entre os pacientes revisados. Métodos: Os ângulos de desvio em posição primária foram medidos usando teste de cobertura prismática em pacientes com boa visão em ambos os olhos e o método de Krimsky naqueles com ambliopia severa. Entre os 46 pacientes operados, 40 foram avaliados 10 anos após a cirurgia. O teste t-Student e o de McNemar foram usados para análises estatísticas. Resultados: Não foram encontradas diferenças significativas nos ângulos de desvio em posição primária entre as medidas realizadas 6 meses e 10 anos pós-operatórios (p=0,922, assim como entre crianças e adultos (p=0,767). Entre os 40 pacientes revisados, apenas cinco apresentaram exotropias, todas pequenas (sendo o maior XT 15Δ). Portanto grandes exotropias consecutivas ao longo do tempo não foram observadas. Conclusão: Nossos resultados sugerem que a cirurgia monocular para corrigir a esotropias de grande ângulo usando amplos recuos do reto medial e grandes ressecções do reto lateral foi viável e segura tanto em adultos quanto em crianças em curto como a longo prazo.


Subject(s)
Humans , Male , Child, Preschool , Child , Adolescent , Adult , Young Adult , Esotropia/surgery , Ophthalmologic Surgical Procedures/methods , Time Factors , Follow-Up Studies , Treatment Outcome , Oculomotor Muscles/surgery
2.
Rom J Ophthalmol ; 62(1): 42-47, 2018.
Article in English | MEDLINE | ID: mdl-29796433

ABSTRACT

AIM: To assess the relationship between the macular pigment optical density and blue-light issued by computers, glare sensibility, with iris color, age, sex, or refractive errors. MATERIAL AND METHODS: 83 patients (166 eyes) were enrolled in a prospective observational study. They were divided into 2 groups: group 1 (study group) - computer using patients (time spent in front of the computer for minimum 8 hours per day, 5 days per week, 2 years) - 43 patients and group 2 (control group) - 40 patients. The following investigations were conducted in all the selected cases: visual acuity, refraction, biomicroscopy, measurement of the MPOD, glare sensitivity, assessment of eye color. RESULTS: 51.81% of the patients were included in group 1, while the rest, 48.19%, were in group 2. Thus, the MPOD had a mean value of (+/ -SD) 0.42+/ -0.13 (t = -1.08, p = 0.28) in group 1, and 0.44+/ -0.16 on the LE. The results showed a MPOD mean value of 0.51+/ - 0.16 in group 2 and 0.51+/ -0 .16. (t = 0.49, p = 0 .62) on the LE. 55.77% of the patients with light colored iris and 56.14% of those with dark iris had a low MPOD. CONCLUSIONS: The data from our study failed to illustrate a significant correlation between MPOD and blue-light issued by computers. Furthermore, a statistic significant relationship regarding iris color, refractive errors, glare, and MPOD was not observed. ABBREVIATIONS: L = lutein, Z = zeaxanthin, MZ = meso-zeaxanthin, AMD = age related macular degeneration, MPOD = macular pigment optical density, MP = macular pigment, HFP = Heterochromatic Flicker Photometry, RE = right eye, LE = left eye.


Subject(s)
Macular Degeneration , Macular Pigment , User-Computer Interface , Visual Acuity , Humans , Light , Lutein , Prospective Studies
3.
Rev. bras. oftalmol ; 72(2): 112-115, mar.-abr. 2013. graf, tab
Article in Portuguese | LILACS | ID: lil-678377

ABSTRACT

OBJETIVO: Avaliar a correlação da fluência e o tempo de parada transoperatória por perda de fixação, como fatores de hiper ou hipocorreções das ametropias pós-Lasik. MÉTODOS: A idade variou entre 19 e 61 anos com média de 31,27 ± 9,99. O tempo mínimo de acompanhamento pós-operatório foi de 90 dias. Foram excluídos indivíduos com topografia corneana pré-operatória com ceratometria máxima maior que 46,5D ou presença de irregularidades; ceratometria média pós-operatória simulada menor que 36,0D; pupilas maiores que 6mm; paquimetria menor que 500 µm; miopia maior que -8,0DE, hipermetropia maior que +5,0DE e astigmatismo maior que -4,0DC. O laser utilizado foi o Esiris Schwind com Eye-Tracking de 350Hz e scanning spot de 0,8 mm. O microcerátomo utilizado foi o M2 da Moria com programação de 130µm de espessura. RESULTADOS: A acuidade visual logMAR pré-operatória com correção variou de 0,40 a 0 com média de 0,23 ± 0,69; a pós-operatória sem correção foi de 0,40 a 0 com média de 0,30 ± 0,68. A mediana foi de 0 logMAR para os dois momentos (p=0,424). No equivalente esférico pré e pós-operatório, notou-se uma óbvia diferença (p< 0,0001), no pré-operatório com média de -4,09 ± 2,83 e o pós com média de -0,04 ± 0,38. A mediana foi de -4,75 no pré e de 0 no pós-operatório. Sessenta e nove casos (78,3%) ficaram plano ± 0,25. A fluência mínima foi de 0,513 mJ/cm² e a máxima de 0,581 mJ/cm² com média de 0,545 ± 0,01, não se percebendo correlação (r= -0,03266; IC 95% -0,241 a 0,178; p= 0,762) entre a fluência e o equivalente esférico final (média= -0,04 ± 0,38) nos olhos operados. O tempo mínimo de parada transoperatória foi de dois segundos e o máximo de 12 segundos com média de 4,90 ± 3,47. Fazendo-se uma correlação (r= 0,08865; IC 95%= -0,123 a 0,293; p= 0,411) entre o equivalente esférico pós-operatório e o tempo de parada transoperatória, não se percebeu diferenças. CONCLUSÃO: Não houve correlação entre a fluência do laser e o tempo de parada transoperatória por perda de fixação, com hiper ou hipocorreções nas ametropias pós-Lasik.


OBJECTIVE: To evaluate the correlation of flow and stopping time intraoperative loss of attachment factors as hypertension or hipocorreções of refractive errors after Lasik. METHODS: The age ranged between 19 and 61 years (mean= 31.27 ± 9.99). The minimum follow-up period was 90 days. Individuals with: corneal topography preoperative maximum keratometry greater than 46.5D or presence of irregularities, corneal curvature postoperative simulated smaller 36.0D, pupils more 6mm; corneal thickness smaller 500 µm; Myopia more -8.0, hyperopia more +5.0DE and astigmatism more -4.0DC. The laser was used with Esir Schwind Eye-Tracking and 350Hz scanning spot of 0.8 mm. The microkeratome used was the Moria M2 with programming 130µm thick. RESULTS: The visual acuity logMAR preoperative correction ranged from 0.40 to 0 (mean= 0.23 ± 0.69) and postoperative uncorrected 0.40-0 (x= 0.30 ± 0, 68). The Median= 0 logMAR for both time points (p= 0.424). For spherical equivalent before and after surgery, we found an obvious difference, with the pre (mean= -4.09 ± 2.83) and post (mean= -0.04 ± 0.38). The Median was -4.75 in the pre and zero postoperatively (p <0.0001). Sixty-nine cases (78.3%) were plan ± 0.25. Fluency minimum= 0.513 mJ/cm2 and maximum= 0.581 mJ/cm2 (mean= 0.545 ± 0.01), no correlation (r = -0.03266, 95% CI -0.241 to 0.178, p = 0.762) between the flow and spherical equivalent (mean = -0.04 ± 0.38) in eyes operated. The minimal downtime during surgery was 02 seconds and maximum was 12 seconds (mean= 4.90 ± 3.47). Making a correlation (r = 0.08865, 95% CI = -0.123 to 0.293, p = 0.411) between the postoperative spherical equivalent and downtime during surgery, not perceived differences. CONCLUSION: There was no correlation between the fluency of the laser during surgery and downtime due to loss of fixation with hipocorreções in hyper-or post-Lasik ametropia.


Subject(s)
Humans , Male , Female , Young Adult , Middle Aged , Keratomileusis, Laser In Situ , Refractive Errors , Visual Acuity
4.
Rev. bras. oftalmol ; 71(3): 164-172, maio-jun. 2012. graf, tab
Article in Portuguese | LILACS | ID: lil-643914

ABSTRACT

OBJETIVO: Verificar as variações entre manhã e tarde da refração, da acuidade visual, das medidas da pressão ocular e dos parâmetros biomecânicos da córnea em pacientes operados de ceratotomia radial e interesse em retratamento refrativo; correlacionar os parâmetros biomecânicos da córnea com a refração, com a acuidade visual e com as suas variações. MÉTODOS: Foram examinados trinta e oito olhos de 19 pacientes pela manhã (9 am) e à tarde (6 pm), obtendo-se refração esfero-cilíndrica dinâmica, acuidade visual (logMAR) sem correção (AVsc) e corrigida (AVcc) e parâmetros do ORA (Ocular Response Analyzer): histerese corneana (corneal hysteresis - CH), fator de resistência da córnea (corneal resistance factor - CRF), pressão intraocular (intraocular pressure &- IOP) calibrada para o padrão Goldmann (IOPg) e pressão compensada da córnea (IOPcc). Considerando a não distribuição normal das variáveis (teste de Kolmogorov-Smirnov), o teste de Wilcoxon signed rank foi utilizado para verificar significância nas diferenças entre as medidas da manhã e as da tarde de cada variável. O teste de Spearman foi utilizado para verificar correlações das medidas do ORA com o estado refracional e com a acuidade visual pela manhã e à tarde, assim como para verificar as correlações entre as medidas do ORA pela manhã e à tarde e as variações da refração e da acuidade visual. RESULTADOS: Grau esférico (E), equivalente esférico (EE), equivalente desfoco (ED), AVsc, IOPcc e IOPg variaram significativamente (Wilcoxon, p<0,05) entre manhã e tarde, havendo maior hipermetropia, pior acuidade visual não corrigida, maior pressão ocular e menor CH pela manhã. Nas medidas pela manhã, observaram-se correlações positivas (Spearman, p<0,05) do EE e do ED com IOPcc (rs=0,39 e 0,34 respectivamente), mas não com IOPg. Nas medidas da tarde, não houve correlações significantes entre os parâmetros refracionais e os pressóricos. Observaram-se correlações negativas (Spearman, p<0,05) entre AVsc (logMAR) e CH pela manhã e à tarde (rs= -0,48 e rs= -0,51), entre E e CH pela manhã e à tarde (rs= -0,66 e -0,76), entre E e CRF pela manhã e à tarde (rs= -0,40 e -0,47), entre EE e CH pela manhã e à tarde (rs= -0,70 e -0,68), entre EE e CRF pela manhã e à tarde (rs= -0,41 e -0,46), entre ED e CH pela manhã e a tarde (rs= -0,64 e -0,54) e entre ED e CRF pela manhã e a tarde (rs= -0,35 e -0,34). Observou-se correlação significante e negativa do CRF pela manhã com a variação do ED (p = 0,05; rs = -0,30) e com a variação da AVsc (p = 0,04; rs = -0,33). CONCLUSÃO: Maior hipermetropia pela manhã foi associada a maior pressão compensada (IOPcc), mas não com IOPg em pacientes operados de ceratotomia radial, o que deve ser considerado no planejamento do retratamento refrativo. Parâmetros biomecânicos (CRF e CH) mais baixos foram associados com maior hipermetropia e pior acuidade visual. Uma tendência de haver maior flutuação relacionada com córneas mais fracas foi encontrada. Novos estudos envolvendo parâmetros biomecânicos derivados do sinal do ORA, além dos parâmetros CH e CRF (derivados das pressões de aplanamento do ORA), juntamente com dados tomográficos da córnea e de aberrometria total são necessários.


PURPOSE: To verify the morning to evening variations of refraction, visual acuity, intraocular pressure and biomechanical parameters on patients operated by radial keratotomy who presented for refractive re-treatments; and to correlate the biomechanical parameters with refraction, visual acuity and their variations among morning and evening. METHODS: 19 patients were examined, respectively thirty-eight eyes in the morning (9 am) and evening (6 pm), recording sphere-cylindrical dynamic refraction, visual acuity (logMAR) without correction (AVsc) and corrected (AVcc) and ORA (Ocular Response Analyzer) parameters: corneal hysteresis (CH), corneal resistance factor (CRF), intraocular pressure calibrated for Goldmann (IOPg) e corneal compensated (IOPcc). Variables had no normal distribution (Kolmogorov-Smirnov test), so that the Wilcoxon signed rank was used for testing the significance on the differences for each variable between morning and afternoon. The Spearman test was used for assessing the correlations between the ORA parameters and refraction, visual acuity in the morning and afternoon, as well as to verify the correlations between the ORA parameters and the variations on refraction and visual acuity. RESULTS: Sphere (E), spherical equivalent (EE), defocus equivalent (ED), AVsc, IOPcc e IOPg varied significantly (Wilcoxon, p<0.05) between morning and evening. There was more hyperopia, worse visual acuity, higher pressure and lower CH in the morning measurements. In the morning measurements, there was a positive correlation (Spearman, p<0.05) between EE and ED and IOPcc (rs=0.39 and 0.34 respectively), but not with IOPg. In the evening measurement, there were no correlations between the refractive and pressure measurements. Negative correlations were observed (Spearman, p<0.05) between AVsc (logMAR) and CH in the morning and in the evening (rs= -0.48 e rs= -0,51), between E and CH in the morning and in the evening (rs= -0.66 and -0.76), between E and CRF in the morning and in the evening (rs= -0.40 and -0.47), between EE and CH in the morning and in the evening (rs= -0.70 and -0.68), between EE and CRF in the morning and in the evening (rs= -0.41 and -0.46), between ED and CH in the morning and in the evening (rs= 0.64 and -0.54) and between ED and CRF in the morning and in the evening (rs= -0.35 and -0.34). There was a significant negative correlation between the morning measurement of CRF and the variation of defocus equivalent (p = 0.05; rs = -0.30) and the variation of AVsc (p = 0.04; rs = -0.33). CONCLUSION: More hyperopia was recorded in the morning which was associated with higher compensated pressure (IOPcc) but not with IOPg ten years after RK. Lower biomechanical parameters (CRF e CH) were associated with higher hyperopia and worse visual acuity. A trend was observed for having higher fluctuation on weaker corneas. New studies involving the variables derived from the waveform signals, beyond CH and CRF (derived from the applanation pressures) along with data from corneal tomography and wavefront aberrometry are necessary.


Subject(s)
Humans , Postoperative Complications , Keratotomy, Radial/adverse effects , Circadian Rhythm/physiology , Cornea/pathology , Hyperopia/etiology , Refraction, Ocular/physiology , Biomechanical Phenomena , Visual Acuity/physiology , Retrospective Studies , Cornea/surgery , Hyperopia/physiopathology , Intraocular Pressure/physiology
5.
Rev. bras. oftalmol ; 68(2): 76-82, mar.-abr. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-517485

ABSTRACT

Objetivo: apresentar os resultados refracionais da utilização de lente intra-ocular tórica na correção do astigmatismo corneano durante a cirurgia da catarata.Métodos: Foram estudados prospectivamente 27 olhos de 18 pacientes portadores de catarata com astigmatismo corneano topográfico maior que 1,0DC e menor que 3,0DC, submetidos à cirurgia de catarata pelo sistema de facoemulsificação no período de julho a dezembro de 2007. Resultados: A acuidade visual não corrigida foi de > 20/40 em 92,59% (25 olhos); a refração pós-operatória foi plana em 66,61% e entre + 0,50 em 92,60%. Conclusão: a utilização da LIO tórica se apresenta como uma boa opção para a neutralização do astigmatismo corneano entre 1,0 e 3,0 dioptrias.


Purpose: To present refraction results using toric intraocular lens for correcting corneal astigmatism duringcataract surgery. Methods: The study comprised 27 eyes of 18 cataract patients with topographic corneal astigmatism higher than 1.0D and lower than 3.0D, submitted to cataract surgery using the phacoemulsification system, during the period of july to december 2007. Results: Non-corrected visual acuity was >20/40 in 92.59% (25 eyes); post-surgical refraction was plana in 66.61% and + 0.50 in 92.60%. Conclusion: the use of toric IOL is a good option to neutralize corneal astigmatism between 1.0 and 3.0 diopters.

SELECTION OF CITATIONS
SEARCH DETAIL
...