Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
1.
Dental press j. orthod. (Impr.) ; 29(2): e2423282, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1557696

ABSTRACT

ABSTRACT Objective: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. Methods: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. Results: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. Conclusions: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


RESUMO Objetivo: O objetivo deste estudo foi comparar o torque de inserção (TI), a resistência flexural (RF) e as alterações de superfície em mini-implantes ortodônticos de aço inoxidável (MIs-Ai) e de liga de titânio (MIs-Ti). Métodos: Vinte e quatro MIs (2 x 10 mm; MIs-Ai, n = 12; MIs-Ti, n = 12) foram inseridos em blocos de osso artificial de densidades de 20 lb/ft3 (20 PCF) e 40 lb/ft3 (40 PCF). O torque máximo de inserção foi registrado por meio de um torquímetro digital. A resistência flexural foi avaliada nas deflexões de 2, 3 e 4 mm. Topografia de superfície e composição química dos MIs foram avaliadas por Microscopia Eletrônica de Varredura (MEV) e Espectroscopia de Energia Dispersiva de Raios X (EDS). Modelos lineares gerais e mistos foram utilizados para avaliar o efeito do tipo de MI, da densidade óssea e da deflexão nos desfechos avaliados. Resultados: O TI dos MIs-Ti foi 1,1 Ncm maior do que o obtido para os MIs-Ai (P = 0,018). O TI para MIs inseridos em blocos de teste de 40 PCF foi 5,4 Ncm maior do que para aqueles inseridos em blocos de teste 20 PCF (p < 0,001). MIs-Ai inseridos em osso de maior densidade (40 PCF) apresentaram resistência flexural significativamente maior do que outros grupos, em deflexões de 2 mm (98,7 ± 5,1 Ncm), 3 mm (112,0 ± 3,9 Ncm) e 4 mm (120,0 ± 3,4 Ncm) (p < 0,001). A MEV evidenciou fraturas nos MIs-Ti. A EDS revelou incorporação de 18% de C e 2,06% de O nos MIs-Ai e 3,91% de C nos MIs-Ti, ambos submetidos a testes mecânicos. Conclusões: Com base nos resultados desse estudo in vitro, os MIs-Ai aparentam oferecer adequada estabilidade e maior resistência mecânica, em comparação aos MIs-Ti, quando inseridos em osso de maior densidade.

2.
RGO (Porto Alegre) ; 71: e20230050, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1514645

ABSTRACT

ABSTRACT Objectives: The objective was to evaluate the longevity of ceramic restorative materials in the manufacture of endocrown restorations, through an in vitro study on surface roughness and mechanical strength. Methods: Three restorative materials were evaluated and assigned to experimental groups (n=10 disc specimens): Leucite Reinforced Ceramic, Lithium Disilicate and Nanoceramic Resin. These restorative materials were evaluated for surface before and after aging (n=02 specimens) under a stereomicroscope. The specimens were submitted to the average surface roughness test (Ra) (n=10) in a contact roughness meter before and after aging. As well as the biaxial flexural strength test (n=10), after aging, up to a test speed of 0.5 mm/min. Aging was carried out in a thermocycler, with 5,000 cycles with baths of 5 °C ± 1 ° and 55 °C ± 1 °. Fragments after fracture were observed under a stereomicroscope. The data obtained were tabulated and analyzed using the Minitab statistical program. Results: The surfaces of the specimens do not show changes between the restorative materials and also in relation to aging. For the roughness data, the restorative material factors (p=0.867) and aging (p=0.321) were not statistically significant. The DIS group presented the highest values of fracture resistance (p=0.000), in relation to the LEU and REN groups, which were statistically similar. The same statistical pattern was identified for post-fracture fragment data (p=0.030). Conclusions: The aging factors and restorative material do not interfere with the surface roughness performance. However, the mechanical performance and number of fragments after fracture is affected by the restorative material.


RESUMO Objetivos: Objetivou-se avaliar a longevidade de materiais restauradores cerâmicos na confecção de restaurações endocrowns, através de um estudo in vitro sobre rugosidade superficial e resistência mecânica. Métodos: Três materiais restauradores foram avaliados e distribuídos em grupos experimentais (n=10 espécimes em disco): Cerâmica Reforçada por Leucita, Dissilicato de Lítio e Resina Nanocerâmica. Estes materiais restauradores foram avaliados quanto a superfície antes e após ao envelhecimento (N=2 espécimes) em estereomicroscópio. Os espécimes foram submetidos ao ensaio de rugosidade superficial média (Ra) (N=10) em rugosímetro de contato antes e após o envelhecimento. Como também, ao teste de resistência à flexão biaxial (N=10), após envelhecimento, em uma velocidade de ensaio de 0,5 mm/min. O envelhecimento foi realizado uma termocicladora, sendo 5.000 ciclos com banhos de 5 °C ± 1° e 55 °C ± 1°. Os fragmentos após fratura foram observados em estereomicroscópio. Os dados obtidos foram tabulados e analisados no programa estatístico Minitab. Resultados: As superfícies dos espécimes não mostram alterações entre os materiais restauradores e também em relação ao envelhecimento. Para os dados de rugosidade, os fatores materiais restauradores (p=0,867) e envelhecimento (p=0,321) não foram estatisticamente significativos. O grupo DIS apresentou os maiores valores de resistência à fratura (p=0,000), em relação aos grupos LEU e REN que foram estatisticamente semelhantes. O mesmo padrão estatístico foi identificado para os dados de fragmentos após a fratura (p=0,030). Conclusão: Os fatores envelhecimento e material restaurador não interferem quanto a performance da rugosidade superficial. No entanto, o desempenho mecânico e número de fragmentos após a fratura é afetado pelo material restaurador.

3.
Braz. dent. sci ; 26(4): 1-8, 2023. ilus, tab
Article in English | BBO - Dentistry , LILACS | ID: biblio-1512140

ABSTRACT

Objective: To evaluate the biaxial flexural strength (BFS) of lithium disilicate (L), cemented on different substrates (epoxy resin - E and metal - M) with dual-cure resin cement (Rc) and zinc phosphate cement (Zc), not aged, thermally aged (TC) or thermo-mechanical aged (TC/MC). Material and Methods: Disks of L, E, and M were fabricated, and the cementation was performed according to the following groups: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Ten samples from each described group were tested in BFS, ten more samples were subjected to TC (1×104 cycles between 5 ºC and 55 ºC water), and the last 10 samples were subjected to TC/MC (MC: 1.2×106 cycles, 50 N, 3.8 Hz). The BFS test was performed and scanning electron microscopy (SEM) was performed to evaluate the failure mode. The effect of the cementation strategy (cement/substrate) was compared in each aging method and the effect of the aging method was evaluated for each cementation strategy by one-way ANOVA and Tukey post-hoc test (α=0.05). Results: The strength values were highest to M (237.8 ~ 463.9 MPa), in comparison to the E (41.03 ~ 66.76 MPa), despite aging and luting agent. Flexural strength data decreased after TC and TC/MC in groups cemented with Zc, but was stable when cemented with Rc. SEM analysis indicated that failure origins were located at the tensile surface of the L. Conclusion: Lithium disilicate discs cemented to the metallic substrate presented the highest biaxial flexural strength. The cementation with dual-cure resin cement did not decrease BFS after aging (AU)


Objetivo: Avaliar a resistência à flexão biaxial (BFS) do dissilicato de lítio (L), cimentado sobre diferentes substratos (resina epóxi - E e metal - M) com cimento resinoso dual (Rc) e cimento de fosfato de zinco (Zc), não envelhecido, submetido ao envelhecido térmico (TC) ou ao envelhecido térmico-mecânico (TC/MC). Material e Métodos: Foram confeccionados discos de L, E e M, e a cimentação foi realizada de acordo com os seguintes grupos: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Dez amostras de cada grupo descrito foram testadas em BFS, mais dez amostras foram submetidas à TC (1×104 ciclos de imersão em água entre 5 ºC e 55 ºC), e as últimas 10 amostras foram submetidas à TC/MC (MC: 1.2 ×106 ciclos, 50 N, 3.8 Hz). Foram realizados os testes de BFS e a microscopia eletrônica de varredura (MEV) para avaliar o modo de falha. O efeito da estratégia de cimentação (cimento/substrato) foi comparado em cada método de envelhecimento e o efeito do método de envelhecimento foi avaliado para cada estratégia de cimentação por ANOVA a um fator e teste post-hoc de Tukey (α=0,05). Resultados: Os valores de resistência foram maiores para M (237.8 ~ 463.9 MPa), em comparação com E (41.03 ~ 66.76 MPa), independentemente do envelhecimento e do agente cimentante utilizado. Os dados de resistência à flexão diminuíram após TC e TC/MC nos grupos cimentados com Zc, mas se mantiveram estáveis quando cimentados com Rc. A análise MEV indicou que a origem das falhas estava localizada na superfície de tração do L. Conclusão: Os discos de dissilicato de lítio cimentados ao substrato metálico apresentaram maior resistência à flexão biaxial. A cimentação com cimento resinoso dual não diminuiu o BFS após o envelhecimento (AU)


Subject(s)
Aging , Cementation , Flexural Strength
4.
RGO (Porto Alegre) ; 71: e20230006, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1431161

ABSTRACT

ABSTRACT The use of removable partial dentures is considered a common and inexpensive treatment option to rehabilitate edentulous areas. The aim of this study was to evaluate the effect of different materials for provisional removable partial dentures, an in vitro study on surface roughness and fracture resistance. Thermopolymerizable acrylic resin and thermoplastic resin specimens with dimensions of 10 x 10 x 2 mm (blocks) (n=10) and with dimensions of 65 x 20 x 3 mm (bars) (n=10 were analyzed for their surface roughness (Ra) and three-point flexural strength test. All specimens were subjected to oven aging for 60 days at 37°C±0.5°C in distilled water. The statistical analysis was performed with a significance level of 5%, and the surface roughness data were submitted to the Two-way Anova statistical test (P < 0.05) and the mechanical strength data were subjected to One-way Anova statistical test (P < 0.05). For roughness, the factor resin type (P = 0.000) and the factor aging (P = 0.000) were statically significant, as well as showing interaction (P = 0.228). The Thermopolymerizable acrylic resin had the lowest mean roughness values compared to the thermoplastic resin and showed no statistical difference after aging. The same scenario was repeated for flexural strength values; Thermopolymerizable acrylic resin was statistically superior to thermoplastic resin (P = 0.000). Thermopolymerized acrylic resin showed lower surface roughness values and higher flexural strength values compared to thermoplastic resin.


RESUMO O uso de próteses parciais removíveis é considerado uma opção de tratamento comum e de baixo custo para reabilitar áreas edêntulas. O objetivo deste estudo foi avaliar o efeito de diferentes materiais para próteses parciais removíveis provisórias, um estudo in vitro sobre rugosidade superficial e resistência à fratura. Espécimes de resina acrílica termopolimerizável e de resina termoplástica com dimensões de 10 x 10 x 2 mm (blocos) (n = 10) e de 65 x 20 x 3 mm (barras) (n = 10) foram analisados em rugosidade superficial média (Ra) e teste de resistência à flexão de três pontos. Todos os espécimes foram submetidos ao envelhecimento em estufa por 60 dias a 37 ° C ± 0,5 ° C em água destilada. A análise estatística se deu com nível de significância de 5%, e os dados de rugosidade superficial foram submetidos ao teste estatístico Anova dois fatores (P <0,05) e os dados de resistência mecânica foram submetidos ao teste estatístico Anova um fator (P <0,05). Para rugosidade, o fator tipo resina (P = 0,000) e o fator envelhecimento (P = 0,000) foram estatisticamente significantes, além de apresentar interação (P = 0,228). A resina acrílica termopolimerizável apresentou menores valores médios de rugosidade em relação à resina termoplástica e não apresentou diferença estatística após envelhecimento. O mesmo cenário foi repetido para valores de resistência à flexão; a resina acrílica termopolimerizável foi estatisticamente superior à resina termoplástica (P = 0,000). A resina acrílica termopolimerizada apresentou menores valores de rugosidade superficial e maiores valores de resistência à flexão em relação à resina termoplástica.

5.
São José dos Campos; s.n; 2023. 57 p. ilus, tab.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1452548

ABSTRACT

Objetivos: Avaliar as propriedades mecânicas, atividade antimicrobiana e citocompatibilidade da zircônia translúcida 5Y-PSZ revestida por vidros experimentais contendo boro e prata. Métodos: Discos 5Y-PSZ (KATANA UTML™, Kuraray Noritake) foram processados e divididos em quatro grupos: polido, sem nenhum revestimento (Controle), aplicação de glaze comercial (Glaze) e vidros experimentais contendo prata (AgCoat) e boro (BCoat). As amostras foram submetidas aos testes de dureza Vickers, testes de flexão biaxial, análise fractográfica e rugosidade através de perfilometria óptica. O potencial antimicrobiano foi caracterizado usando biofilmes de espécie única de Streptococcus mutans e Candida albicans. Foi realizada a quantificação de unidades viáveis formadoras de colônias (UFC), atividade metabólica (CV), ensaios de matriz polissacarídica extracelular (EPS) e biovolume. Biofilmes foram visualizados por microscópio eletrônico de varredura (MEV) e microscopia confocal de varredura a laser (CLSM). A citocompatibilidade foi determinada usando os testes WST-1 e LIVE&DEAD usando células-tronco do ligamento periodontal (PDLSCs) por 24 h. Todas as caracterizações biológicas foram realizadas em triplicatas técnicas e biológicas usando amostras independentes. As análises estatísticas foram realizadas por ANOVA de uma via, teste de Tukey, análise de Weibull e análise de correlação de Pearson. Resultados: BCoat, AgCoat e Glaze alcançaram dureza semelhante, que foi menor que o Controle. BCoat teve a maior resistência à flexão e parâmetros de Weibull (m = 11,5, sF 625 MPa, s0 620) seguido por AgCoat (m = 5,3; sF 464 MPa, s0 478 MPa). BCoat diminuiu significativamente a formação de biofilmes, conforme mostrado pela menor UFC (5,94 log-UFC/mm2) e atividade metabólica (0,17 a.u.) em comparação com os outros grupos (AgCoat: 6,44 log-UFC/mm2, 0,89 a.u.; Glaze: 6,81 log UFC/mm2, 1,21 a.u.; Controle: 6,82 logUFC/mm2, 1,25 a.u.). BCoat e AgCoat apresentaram os menores valores de EPS (0,11 a.u.), seguidos por Glaze e Controle (0,13 a.u.; 0,14 a.u., respectivamente). MEV e CLSM revelaram que os biofilmes no BCoat eram finos, esparsos, com menor biovolume, enquanto os outros grupos produziram biofilmes robustos com maior biovolume. Os ensaios de viabilidade celular não mostraram toxicidade para PDLSCs para todos os grupos. Conclusão: 5Y-PSZ revestida por vidro experimental contendo boro surge como uma estratégia potencial para melhorar as propriedades mecânicas e antimicrobianas do material (AU).


Objectives: To evaluate the mechanical and antimicrobial properties of boroncontaining coating on translucent zirconia (5Y-PSZ). Methods: 5Y-PSZ discs (Control) were coated with a glaze (Glaze), silver- (AgCoat), or boron-containing (BCoat) glasses. The coatings' antimicrobial potential was characterized using S. mutans and C. albicans biofilms through viable colony-forming units (CFU), metabolic activity (CV), and the extracellular polysaccharide matrix (EPS). Biofilm architectures were imaged under scanning electron and confocal laser scanning microscopies (SEM and CLSM). Cytocompatibility was determined at 24 h via WST-1 and LIVE&DEAD assays using periodontal ligament stem cells (PDLSCs). The coatings' effects on mechanical properties were characterized by Vickers hardness, biaxial bending tests, and fractography analysis. Statistical analyses were performed via one-way ANOVA, Tukey's tests, Weibull analysis, and Pearson's correlation analysis. Results: BCoat significantly decreased biofilm formation, having the lowest CFU and metabolic activity compared with the other groups. BCoat and AgCoat presented the lowest EPS, followed by Glaze and Control. SEM and CLSM images revealed that the biofilms on BCoat were thin and sparse, with lower biovolume. In contrast, the other groups all yielded similarly robust biofilms with higher biovolume without compromising PDLSC viability. BCoat, AgCoat, and Glaze also presented similar hardness significantly lower than Control. BCoat had the highest flexural strength, characteristic strength and Weibull parameters (sF : 625 MPa; s0: 620 MPa; m = 11.5), followed by AgCoat (sF : 464 MPa; s0: 478 MPa; m = 5.3). Significance: BCoat is a cytocompatible glass with promising antimicrobial properties that can improve the mechanisms and reliability of 5Y-PSZ (AU).


Subject(s)
Dental Restoration Failure , Dental Plaque , Materials Science , Flexural Strength
6.
Natal; s.n; 2022. 69 p. ilus, tab, graf.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1512936

ABSTRACT

Avaliar a influência de diferentes protocolos de pós processamento e do tipo de impressão 3D na resistência a flexão de três pontos () e estabilidade dimensional de diferentes resinas impressas. Metodologia: A partir da modelagem de uma barra (26 x 2,2 x 2,2mm) em software Meshmixer (Autodesk) e obtenção de arquivo STL, este foi exportado para os softwares das impressoras 3D SLA (Forms 2/Formslab) e LCD (FlashForge Foto 6.0/ FlashForge). Em seguida, 45 barras de cada tipo de resina (Pr - Provisório/Cosmos Temp, Yller; Pl - Placa oclusal/Cosmos Splint, Yller; Mo ­ Modelos/ Cosmos Model, Yller) foram impressas por cada sistema de impressão (SLA e LCD). Após a impressão, as barras de cada tipo de resina foram limpas com álcool isopropílico e distribuídas aleatoriamente (n=15) de acordo com o fator de estudo: "Protocolo de pós processamento" Controle (C: sem pós processamento); Luz Ultravioleta (UV: 15 min em forno Anycubic Wash e Cure Plus, Anycubic) e Micro-ondas (M: 15 min em forno micro-ondas/1.400W). Após, as barras foram submetidas ao teste de  (100KgF, 1mm/min) e os dados (MPa) submetidos à ANOVA 2 fatores e Tukey (5%) para cada tipo de resina. Também foram realizadas as análises complementares de estabilidade dimensional (analisados pelos testes T pareado, ANOVA 2 fatores e Tukey 5%) e MEV das superfícies e fraturas. Resultados: Para a resistência à flexão da resina de modelo, ANOVA 2 fatores indicou que os fatores "Impressora" (p<0,0001) e "Pós processamento" (p<0,0001) apresentaram significância estatística. Os grupos SLAMUV (33.80±4.82AMPa) e LCDMUV (35.93±4.47AMPa) apresentaram maiores valores de , sendo superiores estatisticamente aos grupos sem pós processamento e pós processados em micro-ondas. Para os grupos de resina de provisório, ANOVA 2 fatores revelou que os fatores "Impressora" (p=0,0044) e "Pós processamento" (p<0,0001) apresentaram significância estatística. O grupo LCDPUV apresentou maior resistência à flexão (52,06±12.40AMPa), seguido de SLAPUV (42.86±2.09BMPa) e SLAPMO (26.73±5.48CMPa). Para os grupos de placa, ANOVA 2 fatores mostrou que os fatores "Impressora" (p<0,0001) e "Pós processamento" (p<0,0001) apresentaram significância estatística. O grupo LCDPLUV (91.46±12.33AMPa) apresentou o maior valor de resistência à flexão, sendo estatisticamente superior aos demais grupos. Para estabilidade dimensional, na resina de modelo, o teste T para amostras pareadas demonstrou que apenas as amostras impressas em SLA apresentaram uma alteração significativa da largura e espessura após os métodos de pós processamento. Para o comprimento apenas as amostras pós curadas em luz ultravioleta tiveram alterações significativas (p<0,05). Já com relação a resina para placas o grupo SLAPl-UV a apresentar maiores variações nas três dimensões analisadas (largura: -55,60Aµm; espessura: -12,80Aµm; comprimento: - 93,73Aµm), e por apresentar dados negativos sugere-se expansão do material. Com relação a resina para provisório, em todas as dimensões estudadas o grupo LCDProv-UV apresentou maiores alterações dimensionais (largura: 31,46Aµm; espessura: -28,40Bµm; comprimento: - 86,53Aµm), enquanto o grupo LCDProv-MO apresentou menores alterações (largura: -7,20 Bµm; espessura: -4,40 Aµm; comprimento:18,00Bµm). Conclusão: Pôde-se concluir que o pós processamento em luz ultravioleta promoveu os melhores valores de resistência à flexão para todos os tipos de resinas avaliadas, sendo a técnica de impressão LCD a que apresentou melhores valores de () quando associada ao pós processamento em luz ultravioleta, independente do tipo de resina. A estabilidade dimensional está associada ao tipo de resina e ao pós processamento utilizado (AU).


To evaluate the influence of different post-processing protocols and the type of 3D printing of different printed resins on the three-point bending strength () and dimensional stability. Methodology: A bar was modeled (26 x 2.2 x 2.2mm) on Mishmixer software and a STL file was obtained, the it was exported to the 3D printer software SLA (Forms 2/Formslab) and LCD (FlashForge Photo 6.0/ FlashForge). Then, 45 bars of each type of resin (Pr - Provisional/Cosmos Temp, Yller; Pl - Occlusal Plate/Cosmos Splint, Yller; Mo ­ Models/ Cosmos Model, Yller) were printed by each printing system (SLA and LCD). After printing, the bars of each type of resin were cleaned with isopropyl alcohol and randomly divided (n=15) according to factors: "Post-processing protocol" Control (C: without post-processing); Ultraviolet Light (UV: 15 min in Anycubic Wash and Cure Plus, Anycubic) and Microwave (M: 15 min in microwave oven/1,400W). Thein, the bars were submitted to the  test (100KgF, 1mm/min) and data (MPa) analyzed with 2-way ANOVA and Tukey (5%). Complementary analyzes of dimensional stability (analyzed by paired T tests and 2-way ANOVA) and SEM of surfaces and fractures were also performed. Results: For the flexural strength of the model resin, 2-way ANOVA indicated that the factors "Printer" (p<0.0001) and "Post processing" (p<0.0001) showed statistical significance. The SLAMUV (33.80±4.82AMPa) and LCDMUV (35.93±4.47AMPa) groups presented higher  values, being statistically superior to the groups without post-processing and microwave-processed powders. For the provisional resin groups, 2-way ANOVA revealed that the factors "Printer" (p=0.0044) and "Post processing" (p<0.0001) were statistically significant. The LCDPUV group showed the highest flexural strength (52.06±12.40AMPa), followed by SLAPUV (42.86±2.09BMPa) and SLAPMO (26.73±5.48CMPa). For the plate groups, 2-way ANOVA showed that the factors "Printer" (p<0.0001) and "Post processing" (p<0.0001) were statistically significant. The LCDPLUV group (91.46±12.33AMPa) presented the highest flexural strength value, being statistically superior to the other groups. For dimensional stability, on the template resin, the T-test for paired samples demonstrated that only the SLA printed samples showed a significant change in width and thickness after post-processing methods. For length, only the samples post-cured in ultraviolet light had significant changes (p<0.05). Regarding the resin for plates, the SLAPlUV group presented greater variations in the three dimensions analyzed (width: -55.60Aµm; thickness: -12.80Aµm; length: -93.73Aµm), and for presenting negative data, we suggest material expansion. Regarding the resin for provisional, in all dimensions studied, the LCDProv-UV group showed greater dimensional changes (width: 31.46Aµm; thickness: - 28.40Bµm; length: -86.53Aµm), while the LCDProv-MO group presented minor changes (width: -7.20 Bµm; thickness: -4.40 Aµm; length: 18.00 Bµm). Conclusion: It could be concluded that the post processing in ultraviolet light promoted the best values of flexural strength for all types of resins evaluated, being the LCD printing technique the one that presented the best values of () when associated with post processing in ultraviolet light, regardless of the type of resin. Dimensional stability is associated with the type of resin and post-processing used (AU).


Subject(s)
Dental Materials , Printing, Three-Dimensional , Flexural Strength , Analysis of Variance
7.
Belo Horizonte; s.n; 2022. 23 p.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1415416

ABSTRACT

Reabilitações estéticas e funcionais são tratamentos realizados com bastante frequência na clínica diária do Cirurgião Dentista. Para tais intervenções existem diversos materiais citados na literatura, dentre eles, amálgama, ligas metálicas, resinas compostas e cerâmicas odontológicas. As cerâmicas apresentam inúmeras vantagens que integram estética e resistência, além de adesão aos tecidos dentários, todavia é alvo de uma vasta discussão a respeito de sua resistência mecânica quando se trata de trabalhos minimamente invasivos. A utilização das restaurações cerâmicas em dentes anteriores, submetidos a estresse mecânico reduzido, quando em condições oclusais satisfatórias, é vastamente citada na literatura, inclusive em espessuras extremamente conservadoras. Entretanto, quando se trata de dentes posteriores, onde as cargas oclusais são aumentadas, a espessura torna-se fator preponderante na utilização de tais materiais. Para esclarecer tais dúvidas, o presente estudo tem como objetivo realizar uma revisão da literatura a respeito da influência da espessura das cerâmicas a base de dissilicato de lítio em dentes posteriores na resistência a fratura de tais restaurações. Foi realizado levantamento bibliográfico de artigos publicados nas bases de dados PubMed, Lilacs, Medline, Scielo e Portal de Periódicos CAPES nos últimos 10 anos e, após a leitura dos resumos, selecionados os artigos presentes nesse trabalho. Conclui-se que cerâmicas a base de dissilicato de lítio de espessuras reduzidas devem ser utilizadas em dentes posteriores com cautela, haja vista a importância do equilíbrio oclusal e dos possíveis hábitos parafuncionais muito frequentes nos nossos pacientes.


Aesthetic and functional rehabilitations are treatments performed quite frequently in the daily clinic of the Dental Surgeon. For such interventions there are several materials cited in the literature, among them, amalgam, metal alloys, composite resins and dental ceramics. Ceramics have numerous advantages that integrate aesthetics and resistance, in addition to adhesion to dental tissues, however, it is the subject of a vast discussion regarding their mechanical resistance when it comes to minimally invasive works. The use of ceramic restorations in anterior teeth, submitted to reduced mechanical stress, when in satisfactory occlusal conditions, is widely cited in the literature, including in extremely conservative thicknesses. However, when it comes to posterior teeth, where occlusal loads are increased, thickness becomes a preponderant factor in the use of such materials. To clarify these doubts, the present study aims to review the literature regarding the influence of the thickness of lithium disilicate ceramics in posterior teeth on the fracture resistance of such restorations. A bibliographic survey of articles published in PubMed, Lilacs, Medline, Scielo and Portal de Periódicos CAPES in the last 10 years was carried out and, after reading the abstracts, the articles present in this work were selected. It is concluded that reduced thickness lithium disilicate ceramics should be used in posterior teeth with caution, given the importance of occlusal balance and possible parafunctional habits that are very common in our patients.


Subject(s)
Ceramics , Dental Porcelain , Flexural Strength , Mouth Rehabilitation
8.
J. health sci. (Londrina) ; 23(3): 185-190, 20210920.
Article in English | LILACS-Express | LILACS | ID: biblio-1292749

ABSTRACT

This research aimed to evaluate the bond strength by micro tensile strength (µTBS), elastic modulus (EM) and flexural strength (FS) by the three-point test using three types of composite resins: Charisma Diamond, Filtek Z350 and Tetric N-Ceram Bulk Fill; and three adhesion techniques: adhesive, silane, silane and adhesive. The combinations of each resin with the adhesive technique resulted in nine groups (n = 12). Initially, with the composites, EM and FS tests were performed. Sequentially, each fragment was repaired with the different adhesive systems. All samples were subjected to µTBS testing on a universal assay machine. Data were subjected to the normality test and the parametric ANOVA test. Charisma resin showed the highest values in EM and RF compared to the other composite resins (p <0.05). The highest µTBS value was for silane + adhesive repaired Charisma resin. The lowest µTBS values were in Bulk Fill resin, regardless of adhesive system. The EM and FS results showed that Filtek Z350 resins had the best results, while bulk fill resins had lower results. It was concluded that Charisma and Filtek Z350 resins presented better results. However, in the bulk fill group, the lowest mean values of µTBS, FS and EM were obtained, as well as the lowest value in EM. (AU)


Esta pesquisa teve como objetivo avaliar a resistência de união (RU) por resistência à microtração, módulo de elasticidade (ME) e resistência à flexão (RF) pelo teste de três pontos, utilizando três tipos de resinas compostas: Charisma Diamond, Filtek Z350 e Tetric N-Ceram Bulk Fill; e três técnicas de adesão: adesivo, silano, silano e adesivo. As combinações de cada resina com a técnica adesiva resultaram nove grupos (n = 12). Inicialmente, com os compósitos foram realizados testes de ME e RF. Sequencialmente, cada fragmento foi reparado com os diferentes sistemas adesivos. Todas as amostras foram submetidas ao teste de RU por microtração em uma máquina de ensaio universal. Os dados foram submetidos ao teste de normalidade e ao teste paramétrico ANOVA. A resina Charisma apresentou os maiores valores no ME e RF em relação às demais resinas compostas (p <0,05). O maior valor de RU foi para a resina Charisma reparada com silano + adesivo. Os menores valores de RU foram na resina Bulk Fill, independentemente do sistema adesivo. Os resultados no ME e RF mostraram que as resinas Filtek Z350 obtiveram os melhores resultados, enquanto as resinas bulk fill obtiveram resultados inferiores. Conclui-se que as resinas Charisma e Filtek Z350 apresentaram melhores resultados. Entretanto, no grupo de bulk fill obteve-se as menores médias de RU, RF e ME, bem como o menor valor no ME. (AU)

9.
Rev. bras. med. esporte ; 27(7): 686-688, July 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1351822

ABSTRACT

ABSTRACT Introduction: Centrifugal strength is an important element for strength quality. Developing muscle centrifugal strength can effectively increase the stability of lower limbs and reduce the risk of injury. Objective: To explore the characteristics of contractile force of flexor ahods in strength training and rehabilitation training, and the extensor muscles of the knee joint in athletes with different speeds of centripetal force. Methods: The knee joint muscle group of 8 first-level male high jumpers and 8 second-level male high jumpers were tested by isokinetic centrifugal contraction; the angular test velocity was 60 °/s, 120 °/s, 240 °/s, and the indexes included peak torque, relative peak torque (peak torque/body weight), and the peak torque flexural extension ratio. Results: With the centrifugal contraction of the knee joint muscle group (P < 0.05), the second-level high jumpers should increase the ability of the knee flexor muscle group of the take-off leg. In the case of constant velocity centrifugal contraction (P < 0.01), taking off time must be reduced, that is, taking off speed must be accelerated. Conclusions: The difference in the knee joint muscle isokinetic test results is one of the reasons for the difference in knee joint flexor and extensor muscle contractility under the different speed forces of high jumpers. Level of evidence II; Therapeutic studies - investigation of treatment results.


RESUMO Introdução: A força centrífuga é um elemento importante na qualidade de força. O desenvolvimento da força centrífuga muscular pode, efetivamente, aumentar a estabilidade dos membros inferiores e reduzir o risco de lesões. Objetivo: Explorar as características da força contrátil do músculo flexor no treinamento de força e de reabilitação, e os músculos extensores da junta do joelho em atletas com diferentes velocidades de força centrípeta. Métodos: O grupo muscular da articulação do joelho de oito saltadores de primeiro escalão do sexo masculino, e oito saltadores de segundo escalão do sexo masculino foi testado por contração centrífuga isocinética. A velocidade de teste angular foi de 60 °/s, 120 °/s, 240 °/s, e os índices incluíram torque de pico, torque de pico relativo (torque de pico/peso corporal) e a razão extensão-flexão de torque de pico. Resultados: Na contração centrífuga do grupo muscular da articulação do joelho (P < 0,05), os saltadores de segundo escalão devem aumentar a habilidade do grupo muscular flexor do joelho da perna de arranque. No caso da contração centrífuga de velocidade constante (P < 0,01), o tempo de arranque deve ser reduzido, ou seja, a velocidade de arranque deve ser acelerada. Conclusões: A diferença nos resultados dos testes isocinéticos do músculo da junta do joelho é uma das razões para a diferença na contratilidade muscular flexor e extensor da junta do joelho sob forças de velocidade diferentes em saltadores. Nível de evidência II; Estudos terapêuticos - investigação de resultados de tratamento.


Resumen Introducción: La fuerza centrífuga es un elemento importante en la calidad de fuerza. El desarrollo de la fuerza centrífuga muscular puede efectivamente aumentar la estabilidad de los miembros inferiores y reducir el riesgo de lesiones. Objetivo: Explorar las características de la fuerza contráctil del músculo flexor en el entrenamiento de fuerza y de rehabilitación, y los músculos extensores de la articulación de la rodilla en atletas con diferentes velocidades de fuerza centrípeta. Métodos: Se testó el grupo muscular de la articulación de la rodilla de 8 saltadores de primer escalafón del sexo masculino, y 8 saltadores de segundo escalafón del sexo masculino por contracción centrífuga isocinética. La velocidad de prueba angular fue de 60 °/s, 120 °/s, 240 °/s, y los índices incluyeron torque de pico, torque de pico relativo (torque de pico/peso corporal) y la razón extensión-flexión de torque de pico. Resultados: En la contracción centrífuga del grupo muscular de la articulación de la rodilla (P<0,05), los saltadores de segundo escalafón deben aumentar la habilidad del grupo muscular flexor de la rodilla de la pierna de arrancada. En el caso de la contracción centrífuga de velocidad constante (P<0,01), el tiempo de arrancada debe reducirse, o sea, la velocidad de arrancada debe acelerar. Conclusiones: La diferencia en los resultados de las pruebas isocinéticas del músculo de la articulación de la rodilla es una de las razones para la diferencia en la contractilidad muscular flexor y extensor de la articulación de la rodilla bajo fuerzas de velocidad diferentes en saltadores. Nivel de evidencia II; Estudios terapéuticos - investigación de resultados de tratamiento.

10.
J. bras. econ. saúde (Impr.) ; 13(1): 55-65, Abril/2021.
Article in Portuguese | ECOS, LILACS | ID: biblio-1252727

ABSTRACT

Objetivo: Analisar o custo-efetividade da utilização de ureteroscópios flexíveis descartáveis em comparação com o uso de ureteroscópios flexíveis reprocessáveis. Métodos: Revisão integrativa de literatura realizada nos bancos de dados SciELO, LILACS e MEDLINE, utilizando os descritores "ureteroscopia", "resistência à flexão", "marketing", "análise de custo-benefício" e "esterilização", cujo objeto trata das vantagens custo-efetivas da utilização do ureteroscópio flexível descartável. Resultados: Trinta e cinco artigos foram encontrados, sendo quatro utilizados no estudo. Além disso, características de sete modelos de ureteroscópios flexíveis comercializados no Brasil mais conhecidos atualmente foram apresentadas. Os resultados foram baseados na análise conjunta dos artigos selecionados e características dos modelos de flexíveis apresentados e discutidos em duas categorias: a evolução dos ureteroscópios flexíveis e marketing mix ­ ureteroscópios flexíveis de uso único. Conclusão: Apesar da escassez de pesquisas que se aprofundem em custos de utilização de um ureteroscópio flexível de uso único, comparado a um reprocessável, são notórios os benefícios advindos das inovações agregadas a esses dispositivos, dando retorno positivo tanto para o profissional que faz seu uso deles quanto para o paciente, fazendo-se necessário analisar mais profundamente a possibilidade de migração da "cultura" de uso de ureteroscópios flexíveis reprocessáveis para os descartáveis


Objective: To analyze the cost-effectiveness of using disposable flexible ureteroscopes versus using reprocessable flexible ureteroscopes. Methods: Integrative literature review conducted in the SciELO, LILACS and MEDLINE databases, using the descriptors ureteroscopy, flexion resistance, marketing, cost-benefit analysis, and sterilization, whose object deals with the cost-effective advantages of using the flexible ureteroscope disposable. Results: Thirty-five articles were found and four were used in the study. In addition, characteristics of seven models of flexible ureteroscopes commercialized in Brazil, that are currently better known, were presented. The results were based on a joint analysis of the selected articles and characteristics of the flexible models presented, and discussed in two categories: the evolution of flexible ureteroscopes; and marketing mix - flexible single-use ureteroscopes. Conclusion: Despite the scarcity of research that deepens the costs of using a flexible single-use ureteroscope when compared to a reprocessable one, the benefits arising from the innovations added to these devices are notorious, giving a positive return both to the professional who uses it and to the patient, making it necessary to further analyze the possibility of migration from the "culture" of using flexible reprocessable ureteroscopes to disposable ones


Subject(s)
Sterilization , Cost-Benefit Analysis , Ureteroscopy , Flexural Strength
11.
Araçatuba; s.n; 2021. 58 p. tab, graf.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1435804

ABSTRACT

A aplicação de selantes de superfície poderá ajudar na diminuição da degradação superficial dos blocos de PMMA para CAD/CAM frente aos desafios de absorção de água, variação de temperatura e desafio erosivo causada pelo suco gástrico (frequente em pacientes com refluxo gastroesofágico (DRGE) ou bulimia. Contudo, poucos estudos na área odontológica foram realizados com essas variáveis, sendo necessário o aprofundamento sobre o assunto. Diante disso, o objetivo deste estudo foi avaliar o impacto de diferentes selantes de superfície (Biscovel LV e Palaseal) na preservação das propriedades mecânicas de polímero de PMMA para CAD/CAM, submetidos a termociclagem (T1 - 5.000 ciclos, de 5 e 55oC ; T2 ­ 10.000 ciclos, de 5 e 55oC) e desafio erosivo (DE1 - imersão em HCl 5% (pH=2,0) durante 45 horas e DE2- 91 horas), por meio da rugosidade de superfície (Ra), microdureza Knoop (MK), resistência flexural (RF) e módulo de elasticidade (ME). Foram confeccionados 90 espécimes quadrados (10x10x3 mm) para as análises de Ra e MK e 180 espécimes retangulares (25x2x2mm) para as análises de RF e ME. Os espécimes foram divididos em grupos (n=10) de acordo com o tratamento de superfície e envelhecimento. Os polimentos realizados foram: PA - pontas de borracha Astropol; PA+SB - polimento com PA + aplicação de selante de superfície Biscover LV e PA+SP - polimento com PA + aplicação de selante de superfície Palaseal. As análises foram realizadas após os tratamentos de superfície e após os períodos dos envelhecimentos. Os dados obtidos foram submetidos ao ANOVA (2 fatores), teste Bonferroni (α=0,05) e a análise de regressão linear simples. Na análise de Ra, em todos os períodos de termociclagem o grupo PA obteve os maiores valores de Ra e PA+SP os menores, com diferença significativa entre eles (p< 0.05). De acordo com a análise de regressão linear, todos os grupos apresentaram tendência linear crescente. Já após DE1 e DE2 os três grupos diferiram estatisticamente entre si (p< 0.05), sendo classificados em ordem crescente de rugosidade em PA+SP < PA+SB< PA. O grupo PA+SP manteve os valores de Ra no decorrer dos períodos de análises. Para RF, ocorreu diminuição significativa dos valores de RF do grupo PA após T1 e T2, diferindo estatisticamente dos demais grupos (p< 0.05). O desafio erosivo diminuiu de forma significante (p< 0.05) os valores de RF dos grupos PA e PA+SP após DE1 e, do grupo PA+SB após DE2. Não houve diferenças significativas nas análises de MK e ME, independente dos tratamentos de superfície e envelhecimentos. Conclui-se que os selantes de superfície foram capazes de preservar a rugosidade de superfície e resistência flexural de polímero de PMMA para CAD/CAM submetidos a termociclagem ou desafio erosivo(AU)


The application of surface sealants can help to reduce the surface degradation of PMMA blocks for CAD/CAM in the face of water absorption challenges, temperature variation and erosive challenge caused by gastric juice (common in patients with gastroesophageal reflux (DRGE) or bulimia. However, few studies in the field of dentistry have been conducted with these variables, requiring a more in-depth look at the subject. Therefore, the aim of this study was to evaluate the impact of different surface sealants (Biscovel LV and Palaseal) on the preservation of mechanical properties of PMMA polymer for CAD/CAM, subjected to thermocycling (T1 - 5,000 cycles, from 5 and 55oC; T2 - 10,000 cycles, from 5 to 55oC) and erosive challenge (DE1 - immersion in 5% HCl (pH=2.0) for 45 hours and DE2-91 hours), through surface roughness (Ra), Knoop microhardness (MK), flexural strength (RF) and modulus of elasticity (ME). The Ra and MK analyzes and 180 rectangular specimens (25x2x2mm) for the RF and ME analyses. Specimens were divided into groups (n=10) according to surface treatment and aging. The polishes performed were: PA - Astropol rubber tips; PA+SB - PA polish + application of Biscover LV surface sealant and PA+SP - polish with PA + application of Palaseal surface sealant. Analyzes were performed after surface treatments and after aging periods. The data obtained were submitted to ANOVA (2 factors), Bonferroni test (α=0.05) and simple linear regression analysis. In the analysis of Ra, in all thermocycling periods, the PA group had the highest values of Ra and PA+SP the lowest, with a significant difference between them (p< 0.05). According to the linear regression analysis, all groups showed an increasing linear trend. After DE1 and DE2, the three groups differed statistically from each other (p< 0.05), being classified in ascending order of roughness in PA+SP < PA+SB < PA. The PA+SP group maintained the Ra values throughout the analysis periods. For RF, there was a significant decrease in the RF values of the PA group after T1 and T2, differing statistically from the others groups (p< 0.05). The erosive challenge significantly decreased (p< 0.05) the RF values of the PA and PA+SP groups after DE1 and of the PA+SB group after DE2. There were no significant differences in the MK and ME analyses, regardless of surface treatments and aging. It was concluded that the surface sealants were able to preserve the surface roughness and flexural strength of PMMA polymer for CAD/CAM submitted to thermocycling or erosive challenge(AU)


Subject(s)
Polymers , Dental Prosthesis , Polymethyl Methacrylate , Computer-Aided Design , Dental Materials , Denture, Partial, Temporary , Flexural Strength
12.
São José dos Campos; s.n; 2021. 104 p. ilus, graf, tab.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1362033

ABSTRACT

O objetivo principal deste estudo foi avaliar a influência de diferentes formatos de defeitos superficiais controlados na resistência à flexão em 4 pontos da vitrocerâmica de dissilicato de lítio. Para isso, o estudo foi dividido em dois experimentos, in silico e in vitro. Uma barra para ensaio de flexão 4 pontos foi modelada em CAD e exportada para software CEA para simulação de Análise Estática Estrutural Mecânica por meio do método de elementos finitos. Já para o experimento in vitro, foram confeccionados espécimes em formato de barra a partir de blocos de vitrocerâmica de dissilicato de lítio, que foram divididos em 3 grupos experimentais (n=5) de acordo com o formato do defeito: GC ­ Nenhum; GE ­ Defeito esférico em superfície; GP ­ Defeito pontiagudo em superfície. Para avaliar a morfologia, dimensão dos defeitos introduzidos e rugosidade da superfície do dissilicato de lítio, foram realizadas microscopias eletrônicas de varredura (MEV) e análise por perfilometria óptica 3D. Foi realizado ensaio de resistência à flexão 4 pontos para determinar a resistência à flexão dos espécimes de cada grupo experimental. O grupo controle (GC) apresentou resistência à flexão em 4 pontos média de 217,1 ± 38,2 MPa já os grupos defeito pontiagudo (GP) e defeito esférico (GE) apresentaram resistência à flexão em 4 pontos média de 61,6 ± 2,8 MPa e 186,7 ± 29,4 MPa. A análise qualitativa realizada por microscopia eletrônica de varredura nos espécimes do grupo GP1 possibilitou a visualização de defeitos que apresentam diversas quinas e vértices, além de quatro trincas extensas na superfície do material, localizadas nos vértices da base quadrangular da pirâmide. A partir da análise por perfilometria óptica 3D, observou-se que o grupo controle (GC) apresentou rugosidade média de 0,0614 ± 0,0127 µm, enquanto o grupo defeito pontiagudo (GP) apresentou rugosidade média de 0,0730 ± 0,0313 µm. A partir da análise pelo método de elementos finitos simulando o teste de flexão em 4 pontos, observou-se que o valor de tensão máxima principal atingido pelo grupo controle (GC) foi 108,0 MPa, enquanto o grupo defeito pontiagudo (GP) e o grupo defeito esférico (GE) atingiram valores de tensão máxima principal de 292,0 MPa e 205,5 MPa respectivamente. Para a análise do comportamento mecânico de uma restauração indireta do tipo table-top em dissilicato de lítio e a influência do formato do defeito pelo mesmo método, observou-se que o defeito pontiagudo (GP) apresentou o maior valor de tensão máxima principal, de 284,6 MPa contra 266,15 para a restauração com defeitos esféricos. A restauração sem defeitos presentes obteve valor de 254 MPa. Concluiu-se que os defeitos superficiais promovem a diminuição da resistência à flexão da vitrocerâmica de dissilicato de lítio, sendo o defeito pontiagudo mais prejudicial que o defeito esférico.


The main objective of this study was to evaluate the influence of different shapes of controlled surface defects on the 4-point flexural strength of lithium disilicate glass ceramic. For this, the study was divided into two experiments, in silico and in vitro. A 4-point bending test bar was modeled in CAD and exported to CEA software for simulation of Mechanical Structural Static Analysis using the finite element method. For the in vitro experiment, bar-shaped specimens were made from lithium disilicate glass-ceramic blocks, which were divided into 3 experimental groups (n=5) according to the shape of the defect: GC ­ None; GE ­ Spherical surface defect; GP ­ Sharp surface defect. To assess the morphology, dimension of introduced defects and surface roughness of lithium disilicate, scanning electron microscopy (SEM) and analysis by 3D optical profilometry were performed. A 4-point flexural strength test was performed to determine the flexural strength of the specimens from each experimental group. The control group (CG) had a mean 4-point flexion strength of 217.1 ± 38.2 MPa, whereas the pointed defect (GP) and spherical defect (SG) groups had a mean 4-point flexion strength of 61.6 ± 2.8 MPa and 186.7 ± 29.4 MPa. Qualitative analysis performed by scanning electron microscopy in specimens from the GP1 group allowed the visualization of defects that present several corners and vertices, in addition to four extensive cracks on the surface of the material, located in the vertices of the quadrangular base of the pyramid. From the analysis by 3D optical profilometry, it was observed that the control group (CG) had a mean roughness of 0.0614 ± 0.0127 µm, while the sharp defect group (GP) had a mean roughness of 0.0730 ± 0.0313 µm. From the analysis by the finite element method simulating the 4-point bending test, it was observed that the maximum principal stress value reached by the control group (CG) was 108.0 MPa, while the sharp defect group (GP) and the spherical defect (GE) group reached maximum principal stress values of 292.0 MPa and 205.5 MPa respectively. For the analysis of the mechanical behavior of an indirect restoration of the table-top type in lithium disilicate and the influence of the defect shape by the same method, it was observed that the pointed defect (GP) had the highest maximum principal stress value, of 284.6MPa against 266.15 for the restoration with spherical defects. The restoration with no defects present obtained a value of 254MPa. It was concluded that superficial defects promote a decrease in the flexural strength of lithium disilicate glass-ceramic, with the sharp defect being more harmful than the spherical defect.


Subject(s)
Ceramics , Flexural Strength , Microscopy, Electron, Scanning , Finite Element Analysis , Biomimetic Materials , Lithium
13.
Braz. dent. sci ; 24(4): 1-10, 2021. tab, ilus, graf
Article in English | LILACS, BBO - Dentistry | ID: biblio-1293129

ABSTRACT

Objective: The purpose of this in vitro study is to evaluate the effect of four finish line configurations and two cement types on the fracture resistance of zirconia copings. Material and Methods: Forty yttrium tetragonal zirconia polycrystals copings were manufactured on epoxy resin dies with four preparation designs: knife edge, chamfer, deep chamfer 0.5, 1 mm and shoulder 1 mm. The copings were cemented with two cement types (glass ionomer and resin cement); (n = 5). Two strain gauges were attached on each coping before they were vertically loaded till fracture with a universal testing machine. Data were analyzed by 2-way analysis of variance ANOVA (p < .05). Fractured specimens were examined for mode of failure with digital microscope. Results: Knife edge showed the highest mean fracture resistance (987.04 ± 94.18) followed by Chamfer (883.28 ± 205.42) followed by Shoulder (828.64 ± 227.79) and finally Deep chamfer finish line (767.66 ± 207.09) with no statistically significant difference. Resin cemented copings had higher mean Fracture resistance (911.76 ± 167.95) than glass ionomer cemented copings (821.55 ± 224.24) with no statistically significant difference. Knife edge had the highest strain mean values on the buccal (374.04 ± 195.43) and lingual (235.80 ± 103.46) surface. Shoulder finish line showed the lowest mean strain values on the buccal (127.47 ± 40.32) and lingual (68.35 ± 80.68) with no statistically significant difference. Resin cemented copings had higher buccal (295.05 ± 167.92) and lingual (197.38 ± 99.85) mean strain values than glass ionomer copings (149.14 ± 60.94) and (90.27 ± 55.62) with no statistically significant difference. Conclusion: Vertical knife edge finish line is a promising alternative and either adhesive or conventional cementation can be used with zirconia copings (AU)


Objetivo: O objetivo deste estudo in vitro é avaliar o efeito de quatro configurações de términos cervicais e dois tipos de cimentos na resistência à fratura de copings de zircônia. Material e Métodos: Quarenta copings de zircônia tetragonal policristalina estabilizada por ítrio foram confeccionados em matrizes de resina epóxi com quatro tipos de términos cervicais: lâmina de faca, chanfro, chanfro largo 0,5, 1 mm e ombro 1 mm. Os copings foram cimentados com dois tipos de cimento (ionômero de vidro e cimento resinoso); (n = 5). Dois extensômetros foram fixados em cada coping antes de serem carregados verticalmente até a fratura com uma máquina de teste universal. Os dados foram analisados por análise de variância ANOVA 2 fatores (p < 0,05). Os espécimes fraturados foram examinados quanto ao modo de falha com microscópio digital. Resultados: A Lâmina de faca apresentou a maior média de resistência à fratura (987,04 ± 94,18) seguida pelo Chanfro (883,28 ± 205,42), pelo Ombro (828,64 ± 227,79) e finalmente o Chanfro largo (767,66 ± 207,09), sem diferença estatisticamente significativa. Os copings cimentados com cimento resinoso apresentaram maior média de resistência à fratura (911,76 ± 167,95) em relação aos copings cimentados com ionômero de vidro (821,55 ± 224,24), sem diferença estatisticamente significativa. A lâmina de faca apresentou os maiores valores médios de deformação na superfície vestibular (374,04 ± 195,43) e lingual (235,80 ± 103,46). O término em ombro apresentou os menores valores médios de deformação na superfície vestibular (127,47 ± 40,32) e lingual (68,35 ± 80,68), sem diferença estatisticamente significativa. Os copings cimentados com resina apresentaram maiores valores médios de deformação na superfície vestibular (295,05 ± 167,92) e lingual (197,38 ± 99,85) do que os copings cimentados com ionômero de vidro (149,14 ± 60,94) e (90,27 ± 55,62), sem diferença estatisticamente significativa. Conclusão: O término cervical em lâmina de faca é uma alternativa promissora e a cimentação adesiva ou convencional pode ser usada na cimentação de copings de zircônia. (AU)


Subject(s)
Prosthodontics , Zirconium , Cementation , Tooth Preparation , Flexural Strength
14.
Dental press j. orthod. (Impr.) ; 25(6): 43-48, Nov.-Dec. 2020. tab, graf
Article in English | LILACS, BBO - Dentistry | ID: biblio-1154053

ABSTRACT

ABSTRACT Objective: To evaluate different concentrations of Galla chinensis extract (GCE) added to poly(methyl methacrylate) (PMMA), which is widely used for fabrication of removable orthodontic appliances, regarding the effectiveness of this herbal extract on antimicrobial effect and flexural strength of PMMA. Methods: Acrylic resin samples containing 0.4%, 0.8% and 1.6% GCE were prepared. Flexural strength was investigated via three-point flexural strength test for the 15 acrylic resin blocks of each concentration. Disk diffusion test was used to evaluate antibacterial effects of incorporating the same concentrations of GCE into acrylic resin. All these three groups were compared with the control group, with no added GCE, regarding flexural strength and antibacterial properties. Results: Comparison of flexural strength between the three study groups and the control group showed significant differences between the groups (P=0.018). However, there was no significant difference between the groups containing GCE. There were significant differences in antimicrobial activity between the four groups (P=0.026). Conclusion: Within the limitations of this study, it is suggested that incorporation of GCE into PMMA would be beneficial for antimicrobial activity and flexural strength of PMMA, but further studies on other physical properties and antimicrobial effects on other bacterial strain would be beneficial prior to clinical investigations.


RESUMO Objetivo: Avaliar se diferentes concentrações de extrato de Galla chinensis (EGC) adicionado ao polimetilmetacrilato (PMMA), que é amplamente utilizado para a fabricação de aparelhos ortodônticos removíveis, interferem no efeito antimicrobiano desse extrato e na resistência à flexão do PMMA. Métodos: Foram preparadas amostras de resina acrílica com concentrações de 0,4%, 0,8% e 1,6% de EGC. Para a avaliação da resistência à flexão, utilizou-se o teste de flexão em três pontos para as 15 amostras de resina em cada concentração. O teste de disco-difusão foi utilizado para avaliar os efeitos antibacterianos da incorporação das mesmas concentrações de EGC na resina acrílica. Esses três grupos foram comparados ao grupo controle, sem adição do EGC, em relação à resistência à flexão e quanto às propriedades antimicrobianas. Resultados: As comparações dos três grupos com o grupo controle mostraram diferenças significativas (p=0,018) para a resistência à flexão. Entretanto, não houve diferença significativa entre os grupos contendo EGC. Foram encontradas diferenças significativas na atividade antimicrobiana entre os quatro grupos (p=0,026). Conclusão: Dentro das limitações desse estudo, parece que a incorporação de EGC no PMMA seria benéfica para a atividade antimicrobiana e a resistência à flexão do PMMA. Porém, estudos adicionais sobre outras propriedades físicas e sobre os efeitos antimicrobianos contra diferentes cepas de bactérias seriam interessantes antes de se fazer pesquisas clínicas.


Subject(s)
Acrylic Resins , Denture Bases , Flexural Strength , Anti-Infective Agents , Anti-Bacterial Agents/pharmacology , Materials Testing , Plant Extracts/pharmacology
15.
São José dos Campos; s.n; 2020. 89 p. il., graf., Tab..
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1224640

ABSTRACT

Com advento dos implantes osseointegráveis gerou se a possibilidade de pacientes edêntulos adquirirem próteses fixas. Para tanto são necessários procedimentos de conexão destes implantes à prótese fixa implantossuportada, como furos e entalhes, além de materiais que confiram maior rigidez ao sistema. Dentre os materiais mais usados como infraestrutura destas próteses estão as ligas metálicas como o cobalto-cromo (Co-Cr) fundido, o titânio (Ti) e compósitos. Os compósitos poliméricos reforçados por fibras de carbono (CPRFC) vêm ganhando destaque, porém interrupções nas fibras como furos podem gerar redução das suas propriedades mecânicas. Atualmente, com o desenvolvimento de novas propostas de tratamento de maxila e mandíbula edêntulas, como o tratamento All on Four®, existe a sobre extensão das próteses, gerando cantiléveres mais longos causando maiores tensões sobre o sistema protético, quando perfuradas para a adaptação de munhões. O objetivo deste trabalho é analisar o efeito da concentração de tensão nos CPRFC submetidos a cargas de flexão, com furo.. Para isso, foram confeccionados dois laminados compósitos em fibra de carbono. Um CPRFC foi produzido com matriz termoplástica de poli(sulfeto de fenileno) PPS, processado por Moldagem de Compressão a Quente, e outro da com matriz termorrígida de epóxi, processado via Moldagem por Transferência de Resina (RTM). Após a produção tanto o laminado termoplástico (TP) quanto o termorrígido (TR) foram perfurados e ensaiados em flexão de quatro pontos. O laminado carbono/PPS foi testado com furo de 4 mm, 5 mm e 6 mm. O carbono/epóxi foi testado com furo de 4 mm e 6 mm. Realizou-se então o ensaio de flexão em quatro pontos para determinação da resistência e módulo em flexão. Foi também realizada análise de fratura em flexão. Como resultados houve uma maior resistência e módulo de elasticidade para os laminados TR em todos os grupos comparados aos TP. A presença de furos nas dimensões estudadas não apresentou diferenças significativas no módulo de elasticidade, porém houve diferenças entre a força máxima de ruptura nos compósitos com furo. Portanto, o uso de CPRFC, apesar de que suas propriedades mecânicas em flexão serem menores que ligas metálicas, estes podem ser usados em infraestruturas protéticas devido ao seu alto módulo de elasticidade(AU)


With the advent of osseointegrated implants, the possibility of edentulous patients to acquire fixed prostheses was created. Therefore, procedures are required to connect these implants to the implant-supported fixed prosthesis, such as holes and notches, in addition to materials that provide greater stiffness to the system. Among the materials most used as infrastructure for these prostheses are metallic alloys such as molten cobalt-chromium (Co-Cr), titanium (Ti) and composites. Polymeric composites reinforced by carbon fibers (CPRFC) have been gaining prominence, however interruptions in fibers such as holes can reduce their mechanical properties. Currently, with the development of new proposals for the treatment of edentulous maxilla and mandible, such as the All on Four® treatment, there is an over extension of the prostheses, generating longer cantilevers, causing greater stress on the prosthetic system. The objective of this work is to carry out the analysis of the stress concentration in the CPRFC subjected to bending loads with hole. One of the possibilities of using CPRFC is the acquisition of pre-molded arc-shaped bars, to be drilled for the adaptation of trunnions, which serves as an infrastructure in Bränemark protocols, to be later screwed to the implants. Two carbon fiber composite laminates were manufactured. One CPRFC was produced with the association of thermoplastic matrix of poly (phenylene sulphide) PPS, processed by Hot Compression Molding, and another of the association of carbon fibers with epoxy matrix, processed via Resin Transfer Molding (RTM). After production, both the thermoplastic (TP) and the thermo-rigid (TR) laminates were cut and drilled. The TP laminate was tested without hole, with 4 mm hole, with 5 mm hole and with 6 mm hole. The TR material were divided into three groups, without hole, with a 4 mm hole and with a 6 mm hole. The four-point bending test was then performed to determine the strength and stiffness of laminates. A fracture analysis of delamination was also performed. As a result, there was a greater resistance and modulus of elasticity for the TR laminates in all groups compared to TP. The presence of holes in the studied dimensions did not present significant differences in the modulus of elasticity, however there were differences between the maximum breaking force in composites with a hole. Therefore, the use of CPRFC even though its mechanical properties in bending are less than metallic alloys, these can be used in prosthetic infrastructures due to their high modulus of elasticity(AU)


Subject(s)
Carbon Fiber/adverse effects , Flexural Strength/drug effects
16.
Odontología (Ecuad.) ; 22(2): 45-59, 2020.
Article in Spanish | LILACS | ID: biblio-1103546

ABSTRACT

En conductos radiculares curvos, la utilización de limas que eviten desvíos y fracturas del instrumento por fatiga y que mantengan curvaturas originales son aspectos importantes en el tratamiento endodóntico. Ob-jetivo: Se evaluó la resistencia a la fatiga cíclica de cuatro sistemas reciprocantes en una canaleta dinámica que simuló tres curvaturas diferentes. Materiales y Método: Estudio in vitro; la muestra con 48 limas se dividió en cuatro grupos (n= 12/grupo): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) y Reciproc® Blue (RB), cuatro limas de cada sistema se usaron en una canaleta que simuló tres angulaciones 45°, 60° y 90°; montadas en un motor X-Smart Plus®, las limas se introdujeron 23 mm en los conductos para ser activadas continuamente a 300/500 oscilaciones/minuto hasta que se produjo la fractura. Se registró tiempo y zona de fractura. Se realizó el test Kruskal Wallis con un nivel de confianza del 95% para las comparaciones. Resul-tados: RB presentó mayor resistencia a la fatiga cíclica que WO y WOG en todas las angulaciones y que R a 90° (p= <0,05). R presentó mayor resistencia que WOG a 45° y 60°, sin embargo, a 90° WOG fue superior que R y WO (p<0,05). No hubo diferencias en cuanto a la zona de fractura que aconteció en la porción apical. Conclusiones: La resistencia se reduce cuando aumenta el grado de curvatura. RB fue significativamente más resistente a la fatiga cíclica que WO y WOG en todas las angulaciones y que R a 90°. La zona de fractura se produjo en la porción apical de las limas.


In the curved canals, the use of files that avoid deviations and fractures of the instrument due to fatigue and that maintain original curvatures are important aspects in endodontic treatment. Objective: The resistance to cyclic fatigue of four reciprocating systems was evaluated in a dynamic gutter that stimulated three different curvatures. Materials and Method: In vitro study, the sample with 48 files was divided into four groups (n = 12 /group): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) and Reciproc® Blue (RB), four files from each system were used in a gutter that simulated three angulations 45o , 60 o and 90 o . The files which were mounted on an X-smart Plus® were inserted 23 mm into the conduits to be continuously activated at 300/500 oscillations per minute until the fracture occurred. Time and fracture zone were recorded. The Krustal Wallis test was performed with a 95% confidence level for the comparisons. Results: RB presented greater resis-tance to cyclic fatigue than WO and WOG at 45o and 60o, however, at 90o WOG was higher than R and WO (p<0.05). There were no differences regarding the fracture zone occurred in the apical portion. Conclusions: The resistance decreases when the degree of curvature increases. RB was significantly more resistance to cyclic fatigue than WO and WOG at all angulations and R at 90o. The fracture zone occurred in the apical portion of the files.


Em canais radiculares curvos, o uso de limas que evitem desvios e fraturas do instrumento devido à fadiga e que mantêm as curvaturas originais são aspectos importantes no tratamento endodôntico. Objetivo: avaliar a resistência à fadiga cíclica de quatro sistemas reciprocantes em uma canaleta artificial que simula três curva-turas diferentes. Materiais e Método: estudo in vitro; a amostra com 48 limas foi dividida em quatro grupos (n = 12 / grupo): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) e Reciproc® Blue (RB), quatro limas de cada sistema foram usadas em uma canaleta que simulo três angulações 45 °, 60 ° e 90 °; se montaram em um motor X Smart Plus®, as limas foram inseridas 23 mm nos condutos para serem ativadas continuamente a 300/350 oscilações / minuto até ocorrer uma fratura. O tempo e a zona de fratura foram registrados. O teste de Kruskal Wallis foi realizado com um nível de confiança de 95% para as comparações. Resultados: O RB apresenta maior resistência à fadiga cíclica que o WO e o WOG em todas as angulações e que R a 90 ° (p = <0,05). R apresentou maior resistência que WOG a 45 ° e 60 °, no entanto, a 90 ° WOG foi maior que R e WO (p <0,05). No existiu diferença na zona de fratura que ocorreu na porção apical. Conclusões: a resistência diminui quando o grau de curvatura aumenta. RB foi significativamente mais resistente à fadiga cíclica do que WO e WOG em todos os ângulos e R a 90 °. A zona de fratura ocorre na parte apical das limas.


Subject(s)
Dental Pulp Cavity , Endodontics , Flexural Strength , Stress, Mechanical , In Vitro Techniques
17.
Natal; s.n; 25 jun. 2019. 71 p. ilus, graf, tab.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1552254

ABSTRACT

Objetivo: Investigar o efeito de técnicas de acabamento/polimento, da espessura e do envelhecimento in situ na resistência à flexão, topografia superficial e adesão celular de uma zircônia ultratranslúcida. Metodologia: Duzentas e quarenta barras de zircônia (UT: Prettau Anterior/Ultratranslúcida, Zirkonzahn, Gais, Itália) foram cortadas, lixadas e sinterizadas, sendo metade (120) nas dimensões finais de 8 x 2 x 1mm e as demais nas dimensões de 8 x 2 x 0,5mm. As barras foram divididas em 16 grupos (n=15) de acordo com três fatores: "envelhecimento in situ" (E: com e sem), "espessura"(1: 1 mm ou 05: 0,5mm) e "Acabamento e Polimento" (C: Controle; B:borrachas DhPro, Paraná Brasil; P: Asperização com pontas diamantadas KG Sorensen 4135; PB: Asperização com pontas diamantadas + Pontas de borrachas ). Para os grupos experimentais submetidos ao envelhecimento in situ, foram selecionados 15 pacientes (comitê de ética - 3.133.187), as amostras foram incluídas nas próteses totais provisórias dos pacientes, que utilizaram as próteses com as barras durante 60 dias. As barras foram submetidas ao ensaio de mini flexão de três pontos (1mm/min, 100 kgf). Duas amostras de cada grupo foram preparadas para as análises topográficas em Microscopia Eletrônica de Varredura (MEV), Difração de raios X (DRX), Microscopia de Força Atômica (AFM) e rugosidade superficial. Para o ensaio de adesão celular, seis blocos de zircônia ultra translúcida (2,5 x 2,5 mm), de cada grupo, foram contaminadas com C. albicans (ATCC 90028) para contagem da unidade formadora de colônia (UFC/mL). Os dados do ensaio de mini flexão (MPa) foram analisados por meio de ANOVA (3 fatores) e Tukey (5%); e os dados do ensaio de adesão celular pelo teste Kruskal Wallis (5%). Resultados: ANOVA (3 fatores) revelou que apenas o fator "Acabamento e Polimento" foi estatisticamente significativo para a resistência à mini flexão (p=0,0001). O desgaste apenas com broca diamantada produziu valores de resistência à mini flexão (variando de 257,1 a 292,9MPa) estatisticamente inferiores em relação aos grupos polidos apenas com discos de borracha (variando de 449,8 a 513,5 MPa), para todas as condições experimentais. No que diz respeito à adesão celular, o teste de Kruskal wallis não revelou diferenças significativas entre os grupos experimentais (p=0,053), apesar da rugosidade ter sido estatisticamente significante por meio do ANOVA (p = 0,001) e diferente entre todos os grupos. Conclusão: O ajuste de peças monolíticas de zircônia ultratranslúcida deve ser realizado idealmente com discos de borracha de poliuretano impregnadas com diamantes. Para a adesão celular, os protocolos de acabamento e polimento não interferem na adesão fúngica, apenas na rugosidade superficial, sendo as amostras polidas com borrachas as de maior lisura (AU).


Introduction: The aim of this study was to investigate the influence of different protocols of finishing and polishing, thickness, and aging in situ on flexural strength and cell adhesion of ultratranslucent zirconia. Methodology: 240 zirconia bars (UT: Prettau Anterior/Ultratranslucent, zirkonzahn, Gais, Italy) were cut, polished and sintered, presenting final dimensions of 1,0 x 2 x 8mm, and 0,5 x 2 x 8mm. The bars were divided among 16 groups (n=15) in accordance to three factors "in situ aging"­ 2 levels (With and Withouth "E"), "thickness" ­ 2 levels (1- 1 mm or 05- 0,5mm) and "Finishing and Polishing" ­ 4 levels (CControl, B- Rubber polishing; P- grinding with burs; PB- grinding with burs + polishing). To the experimental groups submitted to in situ aging, 15 patients were selected (ethics commitee - 3.133.187), the samples were included on the temporary prothesis, and the patients used the prothesis with the bars during 60 days. The bars were submitted to mini flexure three points test (1mm/min, load cell 100 kgf). Two samples of each group were prepared to the topographical analysis on Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD), Atomic Force Microscopy (AFM), and surface roughness. For the cell adhesion assay, six blocks of ultratranslucent zirconia (2.5 x 2.5 mm), of each group were contaminated with the C. albicans (ATCC 90028) for counting the colony forming units (CFU / mL). Results: The mechanical test results were analyzed using ANOVA (3 factors) and Tukey (5%); and the cell adhesion assay data by the Kruskal Wallis test (5%. Results: ANOVA (3 factors) revealed that only the "Finishing and Polishing" factor was statistically significant for mini-flexure strength (p = 0.0001). The finishing and polishing with rubber polishers produced mini-flexure resistance values (varying from 257,1 to 292,9 Mpa) statistically lower in relation to the groups polished only with rubber discs (varying from 449,8 to 513,5 Mpa) to all experimental conditions. Concerning to cell adhesion, Kruskal wallis test did not reveal any significant differences between the experimental groups (p=0,053), despite of the fact that, the surface roughness presented itself statistically significant through ANOVA (p = 0,001) and difference between all groups. Conclusion: The adjustment of ultratranslucent zirconia monolithic should preferably be performed with rubber polishers impregnated with polyurethan. Concerning to cell adhesion, the protocols of finishing and polishing do not interfer at fungal adhesion, only on surface roughness, when the samples are polished with the smoothest rubbers (AU).


Subject(s)
Humans , Surface Properties , Cell Adhesion , Dental Polishing , Dental Porcelain , Flexural Strength , Analysis of Variance
18.
RFO UPF ; 24(2): 256-262, maio/ago. 2 2019. tab, ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1049445

ABSTRACT

Objetivo: avaliar a influência de diferentes modos de polimerização sobre a resistência à flexão de três pontos de duas resinas compostas. Métodos: foram confeccionadas 88 amostras, sendo divididas em dois grupos, conforme a resina composta utilizada: Filtek Z350 XT e Forma. Os grupos foram subdivididos, de acordo com diferentes modos de polimerização, em: G1- Z350 por 20s a 1.000 mw/cm²; G2- Forma por 20s a 1.000 mw/cm²; G3- Z350 por 20s a 1.000 mw/cm² e micro-ondas por 3 minutos em 450w; G4- Forma por 20s a 1.000 mw/cm² e micro-ondas por 3 minutos em 450w; G5- Z350 por 2 vezes de 3s a 3.200 mw/cm²; G6- Forma por 2 vezes de 3s a 3.200 mw/cm²; G7- Z350 por 2 vezes de 3s a 3.200 mw/cm² e micro-ondas por 3 minutos em 450w; G8- Forma por 2 vezes de 3s a 3.200 mw/cm² e micro-ondas por 3 minutos em 450w. As amostras foram submetidas ao teste de resistência à flexão de 3 pontos, sob taxa de carregamento de 50 N/min, até a falha completa. Os dados foram analisados estatisticamente por análise de variância com dois fatores (two-way ANOVA) e teste de Tukey. Resultados: não houve diferenças estatísticas entre as resinas compostas e os modos de polimerização utilizados. Conclusão: de acordo com os resultados do estudo, e dentre suas limitações, os modos de polimerização não influenciaram a resistência à flexão, independentemente da resina composta testada. (AU)


Objective: to evaluate the influence of different polymerization modes on the three-point flexural strength of two composite resins. Methods: 88 samples were produced and divided into two groups according to the composite resin used: Filtek Z350 XT and Forma. The groups were subdivided according to different polymerization modes into: G1- Z350 for 20 s at 1000 mw/cm²; G2- Forma for 20 s at 1000 mw/cm²; G3- Z350 for 20 s at 1000 mw/cm² and microwave for 3 min at 450w; G4- Forma for 20 s at 1000 mw/cm² and microwave for 3 min at 450w; G5- Z350 2x for 3 s at 3200 mw/cm²; G6- Forma 2x for 3 s at 3200 mw/cm²; G7- Z350 2x for 3 s at 3200 mw/cm² and microwave for 3 min at 450w; and G8- Forma 2x for 3 s at 3200 mw/cm² and microwave for 3 min at 450w. The samples were subjected to the three-point flexural strength test under a 50 N/min loading rate until complete failure. The data were statistically analyzed using two-way analysis of variance (two-way ANOVA) and Tukey's test. Results: there were no statistical differences between the composite resins and the polymerization modes used. Conclusion: according to the study results and within its limitations, the polymerization modes did not affect flexural strength, regardless of the composite resin tested. (AU)


Subject(s)
Composite Resins/chemistry , Polymerization , Flexural Strength , Reference Values , Materials Testing , Analysis of Variance , Nanoparticles/chemistry , Light-Curing of Dental Adhesives/methods , Microwaves
19.
Belo Horizonte; s.n; 2019. 138 p. ilus, tab, graf.
Thesis in English, Portuguese | BBO - Dentistry , LILACS | ID: biblio-1016420

ABSTRACT

Dentes bovinos têm sido utilizados como substitutos aos humanos em pesquisas odontológicas. Entretanto, faltam dados que suportem o uso da dentina radicular bovina, sobretudo, que analisem o efeito da idade nas propriedades do substrato. Assim, analisou-se o efeito da idade nos aspectos morfológicos, químicos e físicos das dentinas radiculares humana e bovina, em função dos terços da raiz. Trata-se de um estudo experimental, in vitro, aprovado pelo Comitê de Ética em Pesquisa (COEP-UFMG 1.803.933) e pela Comissão de Ética no Uso de Animais (CEUAUFMG 372/2016). A amostra foi composta por dentes unirradiculares, cujas dentinas radiculares foram categorizadas em: humana jovem (HJ, 20-30 anos); humana madura (HM, acima de 60 anos); bovina jovem (BJ, 24-36 meses); e bovina adulta (BA, acima de 48 meses). Os dentes foram seccionados abaixo da junção amelocementária e ao longo eixo da raiz, para a obtenção de hemisecções. Uma hemisecção foi escolhida e cortes foram feitos para a obtenção dos espécimes, conforme cada método de análise. Para as análises dos aspectos morfológicos ­ número, diâmetro e área dos túbulos dentinários ­ os espécimes foram analisados em Microscópio Eletrônico de Varredura. A composição química foi analisada por Espectroscopia de Raios X por Dispersão em Energia, Espectroscopia por Comprimento de Onda Dispersivo e Espectroscopia Raman por Transformada de Fourier. Na análise das propriedades mecânicas, os espécimes foram submetidos aos testes de nanoindentação, resistência à flexão em três pontos e compressão. Para a análise da resistência ao cisalhamento por extrusão, as raízes receberam tratamento endodôntico e foram fixados pinos de fibra de vidro com cimentos resinosos (dual convencional e autoadesivo). As raízes foram seccionadas nos terços radiculares e os espécimes testados em máquina universal de ensaios. Adicionalmente, avaliou-se o grau de conversão dos cimentos resinosos. Os dados foram analisados em software estatístico, nível de significância de 5%. A HM apresentou os menores valores para número, diâmetro e área de túbulos dentinários (p<0,05). A HM apresentou maiores valores de cálcio, razão Ca/P e concentração mineral relativa, com diminuição na organização e qualidade do colágeno (p<0,05). A HM apresentou os maiores valores de nanodureza, módulo de elasticidade e resistência à compressão, mas os menores valores de resistência à flexão e módulo de elasticidade à flexão (p<0,05). A HM apresentou os menores valores de resistência de união, com diferenças entre os terços radiculares (p<0,05). O grau de conversão dos cimentos apresentou uma diminuição ao longo dos terços radiculares (p<0,05). Concluiu-se que a idade possui um efeito nos aspectos morfológicos, químicos e físicos da dentina radicular humana, sem efeito na dentina bovina. Assim, quando da necessidade de substituição da dentina radicular humana pela bovina em pesquisas, é necessário considerar o efeito da idade nos desfechos analisados.


Bovine teeth have been used as a substitute for human teeth in dental research. However, there is a lack of data that support the use of bovine root dentin, mainly, that analyze the effect of age on the properties of the substrate. Thus, the effect of age on the morphological, chemical and physical aspects of human and bovine root dentin was analyzed, in function of the root thirds. This is an in vitro experimental study, approved by the Research Ethics Committee (protocol number: 1.803.933) and the Ethics Committee on the Use of Animals (protocol number: 372/2016). The sample was composed of single-rooted teeth and root dentin was categorized into: young human (YH, 20-30 years); old human (OH, above 60 years); young bovine (YB, 24-36 months); and adult bovine (AB, over 48 months). The roots were sectioned below the cement-enamel and longitudinally to produce two hemi-sections. One hemi-section was chosen and sections were made to obtain the specimens, according to each method of analysis. For the analyzes of the morphological aspects - number, diameter and area of the dentinal tubules - the specimens were analyzed in Scanning Electron Microscope. The chemical composition was analysed by Energy Dispersive Spectroscopy, Wavelength Dispersive Spectroscopy and Fourier Transformed Raman Spectroscopy. In the analysis of the mechanical properties, the specimens were submitted to nano-indentation, three-point flexural and compression tests. For the analysis of the push-out bond strength test, the roots received endodontic treatment and fiber post with resin cements (conventional and selfadhesive dual) were fixed. The roots were sectioned in the root thirds and the specimens tested in a universal testing machine. Additionally, the degree of conversion of the resin cements was evaluated. The data were analyzed in statistical software, level of significance of 5%. The OH presented the lowest values for number, diameter and area of dentinal tubules (p<0.05). OH showed higher values of calcium, Ca/P ratio and relative mineral concentration, with decrease in the organization and quality of the collagen (p<0.05). The OH showed the highest values of nano-hardness, elastic modulus and compressive strength, but the lowest values of flexural strength and flexural modulus (p<0.05). The OH presented the lowest values of bond strength, with differences among the root thirds (p<0.05). The degree of conversion of the cements showed a decrease along the root thirds (p<0.05). It was concluded that age has an effect on the morphological, chemical and physical aspects of human root dentin, with no effect on bovine dentin. Thus, when it is necessary to replace the human root dentin by the bovine in research, it is necessary to consider the effect of age on the analysed outcomes.


Subject(s)
Tooth Root , Resin Cements , Dental Pins , Dentin , Fractures, Compression , Elastic Modulus , Flexural Strength , Hardness Tests , Microscopy
20.
Belo Horizonte; s.n; 2019. 138 p. ilus, tab.
Thesis in English, Portuguese | LILACS, BBO - Dentistry | ID: biblio-1016737

ABSTRACT

Dentes bovinos têm sido utilizados como substitutos aos humanos em pesquisas odontológicas. Entretanto, faltam dados que suportem o uso da dentina radicular bovina, sobretudo, que analisem o efeito da idade nas propriedades do substrato. Assim, analisou-se o efeito da idade nos aspectos morfológicos, químicos e físicos das dentinas radiculares humana e bovina, em função dos terços da raiz. Trata-se de um estudo experimental, in vitro, aprovado pelo Comitê de Ética em Pesquisa (COEP-UFMG 1.803.933) e pela Comissão de Ética no Uso de Animais (CEUAUFMG 372/2016). A amostra foi composta por dentes unirradiculares, cujas dentinas radiculares foram categorizadas em: humana jovem (HJ, 20-30 anos); humana madura (HM, acima de 60 anos); bovina jovem (BJ, 24-36 meses); e bovina adulta (BA, acima de 48 meses). Os dentes foram seccionados abaixo da junção amelocementária e ao longo eixo da raiz, para a obtenção de hemisecções. Uma hemisecção foi escolhida e cortes foram feitos para a obtenção dos espécimes, conforme cada método de análise. Para as análises dos aspectos morfológicos ­ número, diâmetro e área dos túbulos dentinários ­ os espécimes foram analisados em Microscópio Eletrônico de Varredura. A composição química foi analisada por Espectroscopia de Raios X por Dispersão em Energia, Espectroscopia por Comprimento de Onda Dispersivo e Espectroscopia Raman por Transformada de Fourier. Na análise das propriedades mecânicas, os espécimes foram submetidos aos testes de nanoindentação, resistência à flexão em três pontos e compressão. Para a análise da resistência ao cisalhamento por extrusão, as raízes receberam tratamento endodôntico e foram fixados pinos de fibra de vidro com cimentos resinosos (dual convencional e autoadesivo). As raízes foram seccionadas nos terços radiculares e os espécimes testados em máquina universal de ensaios. Adicionalmente, avaliou-se o grau de conversão dos cimentos resinosos. Os dados foram analisados em software estatístico, nível de significância de 5%. A HM apresentou os menores valores para número, diâmetro e área de túbulos dentinários (p<0,05). A HM apresentou maiores valores de cálcio, razão Ca/P e concentração mineral relativa, com diminuição na organização e qualidade do colágeno (p<0,05). A HM apresentou os maiores valores de nanodureza, módulo de elasticidade e resistência à compressão, mas os menores valores de resistência à flexão e módulo de elasticidade à flexão (p<0,05). A HM apresentou os menores valores de resistência de união, com diferenças entre os terços radiculares (p<0,05). O grau de conversão dos cimentos apresentou uma diminuição ao longo dos terços radiculares (p<0,05). Concluiu-se que a idade possui um efeito nos aspectos morfológicos, químicos e físicos da dentina radicular humana, sem efeito na dentina bovina. Assim, quando da necessidade de substituição da dentina radicular humana pela bovina em pesquisas, é necessário considerar o efeito da idade nos desfechos analisados.


Bovine teeth have been used as a substitute for human teeth in dental research. However, there is a lack of data that support the use of bovine root dentin, mainly, that analyze the effect of age on the properties of the substrate. Thus, the effect of age on the morphological, chemical and physical aspects of human and bovine root dentin was analyzed, in function of the root thirds. This is an in vitro experimental study, approved by the Research Ethics Committee (protocol number: 1.803.933) and the Ethics Committee on the Use of Animals (protocol number: 372/2016). The sample was composed of single-rooted teeth and root dentin was categorized into: young human (YH, 20-30 years); old human (OH, above 60 years); young bovine (YB, 24-36 months); and adult bovine (AB, over 48 months). The roots were sectioned below the cement-enamel and longitudinally to produce two hemi-sections. One hemi-section was chosen and sections were made to obtain the specimens, according to each method of analysis. For the analyzes of the morphological aspects - number, diameter and area of the dentinal tubules - the specimens were analyzed in Scanning Electron Microscope. The chemical composition was analysed by Energy Dispersive Spectroscopy, Wavelength Dispersive Spectroscopy and Fourier Transformed Raman Spectroscopy. In the analysis of the mechanical properties, the specimens were submitted to nano-indentation, three-point flexural and compression tests. For the analysis of the push-out bond strength test, the roots received endodontic treatment and fiber post with resin cements (conventional and selfadhesive dual) were fixed. The roots were sectioned in the root thirds and the specimens tested in a universal testing machine. Additionally, the degree of conversion of the resin cements was evaluated. The data were analyzed in statistical software, level of significance of 5%. The OH presented the lowest values for number, diameter and area of dentinal tubules (p<0.05). OH showed higher values of calcium, Ca/P ratio and relative mineral concentration, with decrease in the organization and quality of the collagen (p<0.05). The OH showed the highest values of nano-hardness, elastic modulus and compressive strength, but the lowest values of flexural strength and flexural modulus (p<0.05). The OH presented the lowest values of bond strength, with differences among the root thirds (p<0.05). The degree of conversion of the cements showed a decrease along the root thirds (p<0.05). It was concluded that age has an effect on the morphological, chemical and physical aspects of human root dentin, with no effect on bovine dentin. Thus, when it is necessary to replace the human root dentin by the bovine in research, it is necessary to consider the effect of age on the analysed outcomes.


Subject(s)
Tooth Root , Resin Cements , Dental Pins , Dentin/anatomy & histology , Fractures, Compression , Flexural Strength , Hardness Tests , In Vitro Techniques , Microscopy, Electrochemical, Scanning , Microscopy
SELECTION OF CITATIONS
SEARCH DETAIL
...