Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 377
Filter
1.
J Arthroplasty ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38897263

ABSTRACT

BACKGROUND: Outpatient primary total knee arthroplasty (TKA) has been well-established as a safe and effective procedure; however, the safety of outpatient revision TKA remains unclear. Therefore, this study utilized a large database to compare outcomes between outpatient and inpatient revision TKA. METHODS: An all-payor database was queried to identify patients undergoing revision TKA from 2010 to 2022. Patients who had diagnosis codes related to periprosthetic joint infection (PJI) were excluded. Outpatient surgery was defined as a length of stay < 24 hours. Cohorts were matched by age, sex, Elixhauser Comorbidity Index, comorbidities (diabetes, obesity, tobacco use), components revised (1-versus 2-component), and revision etiology. Medical complications at 90 days and surgical complications at 1 and 2 years postoperatively were evaluated through multivariate logistic regression. A total of 4,342 aseptic revision TKAs were included. RESULTS: No differences in patient characteristics, procedure type, or revision etiologies were seen between groups. The outpatient cohort had a lower risk of PJI (odds ratio (OR): 0.547, 95% confidence interval (CI): 0.337 to 0.869; P = .012), wound dehiscence (OR: 0.393, 95% CI: 0.225 to 0.658; P < .001), transfusion (OR: 0.241, 95% CI: 0.055 to 0.750; P = .027), reoperation (OR: 0.508, 95% CI: 0.305 to 0.822; P = .007), and any complication (OR: 0.696, 95% CI: 0.584 to 0.829; P < .001) at 90 days postoperatively. At 1 year and 2 years postoperatively, outpatient revision TKA patients had a lower incidence of revision for PJI (OR: 0.332, 95% CI: 0.131 to 0.743; P = .011 and OR: 0.446, 95% CI; 0.217 to 0.859; P = .020, respectively) and all-cause revision (OR: 0.518, 95% CI: 0.377 to 0.706; P < .001 and OR: 0.548, 95% CI: 0.422 to 0.712; P < .001, respectively). CONCLUSIONS: Our findings suggest that revision TKA can be safely performed on an outpatient basis in appropriately selected patients who do not have an increased risk of adverse events relative to inpatient revision TKA. However, we could not ascertain case complexity in either cohort, and despite controlling for several potential confounders, other less tangible differences could exist between groups.

2.
J Arthroplasty ; 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38857712

ABSTRACT

BACKGROUND: The purpose of this study was to evaluate the management and outcomes of aseptic revision total knee arthroplasty (arTKA) with unsuspected positive cultures (UPCs) compared to those with sterile cultures. METHODS: The institutional database at a single tertiary center was retrospectively reviewed for arTKA from January 2013 to October 2023. Patients who met Musculoskeletal Infection Society criteria for periprosthetic joint infection (PJI) based on available preoperative infectious workup, received antibiotic spacers, or did not have at least 1 year of follow-up were excluded. Patients were stratified based on intraoperative cultures into 4 cohorts: sterile cultures, 1 UPC, ≥ 2 UPCs with different organisms, and ≥ 2 UPCs with the same organism. Univariable analyses were used to compare these groups. Kaplan-Meier survivorship analysis assessed infection-free survival at 5 years, and Cox proportional hazards regressions were used to evaluate factors that influence infection-free survival. A total of 691 arTKAs at a mean follow-up of 4.2 years were included in the study. Of these, 49 (7.1%) had 1 UPC with a new organism, 10 (1.4%) had ≥2 UPCs of the same organism, and 2 (0.2%) had ≥2 UPCs with different organisms. RESULTS: Postoperative antibiotics were prescribed to 114 (16.5%) patients-13 (26.5%) with 1 UPC, 6 (60.0%) with ≥2 UPCs of the same organism, and 0 (0.0%) of patients who had ≥2 UPCs of different organisms. There were no differences in infection-free survival at 5 years between patients who had sterile cultures and 1 UPC (96 versus 89%; P = .39) nor between sterile cultures and ≥2 UPCs of different organisms (96 versus 100%; P < .72). However, patients who had ≥2 UPCs of the same organism had significantly worse infection-free survival at 5 years compared to patients who had sterile cultures (58 versus 96%; P < .001). Cox proportional hazards regression suggested that when adjusting for covariates, an American Society of Anesthesiologists classification of ≥3 (hazard ratio [HR] = 3.1; P = .007), ≥2 UPCs of the same organism (HR = 11.0; P < .001), 1 UPC (HR = 4.2; P = .018), and arTKA with hinge constructs (HR = 4.1; P = .008) were associated with increased risk of rerevision for PJI. CONCLUSIONS: Patients who had 1 UPC or ≥2 UPCs with different organisms had similar infection-free survival at 5 years as patients who had sterile cultures. However, patients who had ≥2 UPCs of the same organism had significantly worse infection-free survival at 5 years. Overall, 1 UPC or ≥2 UPCs of the same organism at the time of arTKA may suggest the patient is at higher risk of rerevision for PJI. More studies are needed to determine what interventions can be implemented to mitigate this risk.

3.
Orthop Surg ; 16(7): 1657-1664, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38790115

ABSTRACT

OBJECTIVE: Both porous metal cones and metaphyseal sleeves are excellent implants for reconstructing severe bone defects in the knee joint, but they both exhibit design limitations. The porous metal cone, especially, has significant room for improvement in its shape design. The existing porous metal cones often feature a conical external surface with a relatively small taper, potentially compromising both rotational and axial stability. To improve both axial and rotational stability in porous metal cones, we developed a 3D-printed stepped porous metal cone. This study aimed to assess the short-term clinical outcome of the 3D-printed stepped porous metal cone and to compare it with the clinical outcome of patients who underwent revision total knee arthroplasty (rTKA) with the metaphyseal sleeves during the same period. METHOD: Patients who underwent total knee arthroplasty revision with metaphyseal bone defect reconstruction from 2019 to 2021 were retrospectively analyzed. A total of 61 patients were enrolled in the study, including 15 patients using 3D-printed stepped porous metal cones and 46 patients using metaphyseal metal sleeves. Thirty patients using metaphyseal sleeves were screened by propensity score matching method and compared with those using stepped cones. Analysis included the American Knee Society Score, the Hospital for Special Surgery knee score, the Western Ontario and McMaster Universities Arthritis index, the Short Form 12 (SF-12) health survey, and radiographic assessment with a mean follow-up of 28.5 ± 8.3 months. To conduct comparative analyses, unpaired Student's t-tests were employed for continuous variables, while categorical variables were analyzed using the appropriate Fisher exact or chi-squared test. RESULTS: In this study, the survival rates of both the stepped cone and metaphyseal sleeve were 100%. There was no statistically significant difference in postoperative knee function scores between the two groups (p > 0.05). However, patients in the cone group had significantly higher mental component summary scores on the SF-12 scale (p < 0.05) and higher increases in mean postoperative physical component summary scores than patients in the sleeve group (p < 0.05). In addition, patients in the cone group experienced fewer intraoperative and postoperative complications compared to the sleeve group. CONCLUSION: The 3D-printed stepped porous metal cone can effectively reconstruct bone defects in complex rTKA and provide satisfactory early clinical and radiographic results. The 3D-printed stepped cone provides a more stable structure similar to the sleeve while maintaining the original benefits of the cone making it a promising choice for rTKA.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Printing, Three-Dimensional , Prosthesis Design , Humans , Female , Male , Aged , Retrospective Studies , Arthroplasty, Replacement, Knee/methods , Middle Aged , Porosity , Reoperation/methods
4.
J Arthroplasty ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38797450

ABSTRACT

BACKGROUND: Recent studies have focused on the safety and efficacy of performing primary total knee arthroplasty (TKA) in an outpatient setting. Despite being associated with greater costs, much less is known about the accompanying impact on revision TKA (rTKA). The purpose of this study was to describe the trends in costs and outcomes of patients undergoing inpatient and outpatient rTKA. METHODS: An observational cohort study was conducted using commercial claims databases. Patients who underwent 1-component and 2-component rTKA in an inpatient setting, hospital outpatient department (HOPD), or ambulatory surgery center (ASC) from 2018 to 2020 were included. The primary outcome was the 30-day episode-of-care costs following rTKA. Secondary outcomes included surgical cost, 90-day readmission rate, and emergency department visit rate. Covariates for analyses included patient demographics, surgery type, and indication for revision. RESULTS: There were 6,515 patients who were identified, with 17.0% of rTKAs taking place in an outpatient setting. On adjusted analysis, patients in the highest quartile of 30-day postoperative costs were more likely to be those whose rTKA was performed in an inpatient setting. One-component revisions were more common in an outpatient setting (HOPD, 50.7%; ASC, 62.0%) compared to an inpatient setting (39.6%). The 90-day readmission rates were higher (P = .003) for rTKAs performed in inpatient (+9.2%) and HOPD (+8.6%) settings compared to those in an ASC. CONCLUSIONS: The ASC may be a suitable setting for simpler revisions performed for less severe indications and is associated with lower costs and 90-day readmission and emergency department visit rates.

5.
Orthop Clin North Am ; 55(3): 323-332, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38782504

ABSTRACT

This study was a retrospective cohort analysis of 20 patients who underwent 23 revision total knee arthroplasty procedures in a single geographic region of the United States from January 2015 to February 2023. We analyzed their 25-OH vitamin D levels preoperatively and postoperatively at 1 month, 3 months, 6 months, 1 year, and 2 years. We categorized their supplementation regimens by dose: none, low dose (1000 IU and below), medium dose (1001-5000 IU), and high dose (>5000 IU). We found that there was a high incidence of vitamin D deficiency in this patient population.


Subject(s)
Arthroplasty, Replacement, Knee , Dietary Supplements , Reoperation , Vitamin D Deficiency , Vitamin D , Humans , Retrospective Studies , Vitamin D Deficiency/epidemiology , Male , Female , Reoperation/statistics & numerical data , Aged , Vitamin D/blood , Vitamin D/administration & dosage , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Aged, 80 and over , Incidence
6.
Int Orthop ; 2024 May 06.
Article in English | MEDLINE | ID: mdl-38709260

ABSTRACT

PURPOSE: Unexpected positive cultures are defined as a single positive culture in intraoperative samples taken during revision surgery after prosthetic joint infection was preoperatively ruled out. This study aims to determine the prevalence of unexpected positive cultures (UPC) in revision total knee arthroplasty (TKA) after unicompartmental knee arthroplasty (UKA). As a secondary objective, this study aims to compare the re-intervention rate in this specific group, between UPC and non-UPC patients. The hypothesis is that the UPC prevalence in patients who undergo a revision TKA after UKA is not higher than in other TKA revision cases and this does not increase the risk of re-intervention. METHODS: This is a retrospective study where all patients who underwent a UKA revision from January 2016 to February 2023 in a high-volume arthroplasty centre, were analyzed. Unexpected positive culture prevalence in this group of patients was obtained. RESULTS: During the included period, 270 UKA revision surgeries were performed. Eight cases had at least two positive cultures and were therefore excluded. The final analysis included 262 patients. Of these, 8 (3.05%) patients presented UPCs and the isolated microorganisms were low-virulence organisms. None of the UPC patients received any treatment. No statistical differences were found between UPC and non-UPC groups in the analyzed variables. CONCLUSION: The prevalence of unexpected positive cultures in patients following revision of unicompartmental knee arthroplasty is lower than in patients who undergo a revision of total knee arthroplasty. In UKA patients a UPC does not seem to increase the risk of a re-intervention, so it can be safely ignored if ICM criteria are not met.

8.
Arch Orthop Trauma Surg ; 144(5): 2283-2295, 2024 May.
Article in English | MEDLINE | ID: mdl-38625551

ABSTRACT

INTRODUCTION: The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates. METHODS: Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan-Meier curve and compared between groups via Log-Rank-Tests. RESULTS: 3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7). CONCLUSION: There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Prosthesis Failure , Registries , Reoperation , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Germany/epidemiology , Reoperation/statistics & numerical data , Male , Aged , Female , Tibia/surgery , Middle Aged , Bone Cements
9.
Knee ; 48: 157-165, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38642542

ABSTRACT

BACKGROUND: Revision total knee arthroplasty can successfully restore function and relieve pain for patients with failed knee replacements. Mobile-bearing implants were designed to provide greater congruency between the implant and the polyethylene insert. The goal of this study was to review the clinical outcomes and survivorship for a revision mobile-bearing tibial design. METHODS: A retrospective outcomes review was conducted to assess survivorship and clinical outcomes for a mobile bearing tibial tray, used with metaphyseal sleeves, in revision total knee arthroplasty. RESULTS: At time of furthest follow-up, KM estimates (95% CI; n with further follow-up) for all-cause revision were 82.5% (75.8%; 87.5%; 42) at 7 years for the clinical assumption (CA), and 88.5% (84.4%,91.6%; 53) at 13 years for the registry assumption (RA). For revision of the tray as the endpoint, survivorship estimates were 93.4% (87.0%,96.7%; 42) at 7 years for CA, and 96.2% (93.2%,97.9%; 53) at 13 years for RA. CONCLUSION: In this single-center registry evaluation, we found excellent mid-term survivorship and clinical outcomes for a mobile-bearing tibial tray used with metaphyseal sleeves in revision total knee arthroplasty.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Prosthesis Failure , Registries , Reoperation , Humans , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Retrospective Studies , Male , Aged , Female , Middle Aged , Tibia/surgery , Treatment Outcome , Aged, 80 and over
10.
J Arthroplasty ; 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38677340

ABSTRACT

BACKGROUND: Highly porous metal tibial metaphyseal cones (TMCs) are commonly utilized in revision total knee arthroplasty (TKA) to address bone loss and obtain biologic fixation. Mid-term (5 to 10 year) studies have previously demonstrated excellent survivorship and high rates of osseointegration, but longer-term studies are lacking. We aimed to assess long-term (≥ 10 year) implant survivorship, complications, and clinical and radiographic outcomes after revision TKA with TMCs. METHODS: Between 2004 and 2011, 228 revision TKAs utilizing porous tantalum TMCs with stemmed tibial components were performed at a single institution and were retrospectively reviewed. The mean age at revision was 65 years, the mean body mass index was 33, and 52% were women. Implant survivorship, complications, and clinical and radiographic outcomes were assessed. The mean follow-up was 6.3 years. RESULTS: The 10-year survivorship free of aseptic loosening leading to TMC removal was 97%, free of any TMC removal was 88%, free of any re-revision was 66%, and free of any reoperation was 58%. The most common indications for re-revision were periprosthetic joint infection, instability, and aseptic femoral component loosening. The 10-year nonoperative complication rate was 24%. The mean Knee Society scores increased from 38 preoperatively to 69 at 10 years. There were 8 knees that had evidence of partial, progressive tibial radiolucencies at 10 years. CONCLUSIONS: Porous tantalum TMCs demonstrated persistently durable longer-term survivorship with a low rate of implant removal. The rare implant removals for component loosening or instability were offset by those required for periprosthetic joint infection, which accounted for 80% of cone removals. Porous tantalum TMCs provide an extremely reliable tool to address tibial bone loss and achieve durable long-term fixation in revision TKA. LEVEL OF EVIDENCE: IV.

11.
J Arthroplasty ; 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38599530

ABSTRACT

BACKGROUND: Despite its limitations, a culture remains the "gold standard" for pathogen identification in patients who have periprosthetic joint infection (PJI). Recently, a synovial fluid antigen test has been introduced by a commercial entity. The purpose of this multicenter study was to determine the accuracy of the antigen test in the diagnosis of PJI. METHODS: This retrospective study identified 613 patients undergoing revision total knee arthroplasty who had undergone preoperative synovial fluid analysis. A PJI was defined using the 2018 International Consensus Meeting (ICM) criteria. Patients who had an extended period (> 180 days) from aspiration to revision procedure (n = 62), those presenting within 90 days of their index arthroplasty procedure (n = 17), and patients who had an inconclusive ICM score (n = 8) were excluded. Using receiver operator characteristic curve analyses, we examined the utility of the microbial identification (MID) antigen test and any positive culture (either preoperative or intraoperative) in the diagnosis of PJI. RESULTS: A total of 526 patients were included. Of these, 125 (23.8%) were ICM positive and 401 (76.2%) were ICM negative. Culture demonstrated an area under the curve (AUC) of 0.864, sensitivity of 75.2%, and specificity of 97.5%. On the other hand, the MID test exhibited an AUC of 0.802, sensitivity of 61.6%, and specificity of 98.8%. The AUC of culture was significantly higher than that of the MID test (P = .037). The MID test was positive in 41.9% of culture-negative PJI cases. We also observed a high rate of discordance (29.7%) when both culture and the MID test were positive in the ICM-positive group. CONCLUSIONS: Synovial fluid antigen testing does not provide additional clinical benefit when compared to traditional cultures for the diagnosis of PJI. The antigen test had low sensitivity in the diagnosis of PJI and a relatively high rate of discordance with culture. LEVEL OF EVIDENCE: Level III.

12.
J Arthroplasty ; 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38604279

ABSTRACT

BACKGROUND: Tibial bone defects are commonly encountered in revision total knee arthroplasty (rTKA) and can be managed with metaphyseal cones or sleeves. Few studies have directly compared tibial cones and sleeves in rTKA, and none have limited this comparison to the most severe tibial defects. The purpose of this study was to evaluate and compare the outcomes of metaphyseal cones and sleeves for tibial reconstruction in rTKA regarding implant fixation and clinical outcomes. METHODS: A retrospective review was conducted on patients undergoing rTKA in which metaphyseal cones or sleeves were utilized for addressing metaphyseal bone loss (34 cones and 18 sleeves). Tibial bone loss was classified according to the Anderson Orthopaedic Research Institute bone defect classification, with types 2B and 3 being included. Patient-reported outcomes and postoperative complications were collected, and a radiographic evaluation of osseointegration or loosening was performed. RESULTS: There were 52 knees included (34 cones, 18 sleeves), with a median follow-up of 41.0 months. All-cause implant survival was 100% at 2 years and 96% (95% confidence interval: 76 to 99%) at 4 years, with 98% of tibial components demonstrating osseointegration at the final follow-up. During follow-up, there were a total 11 revisions, of which 1 sleeve was revised secondary to implant loosening. Tibial sleeves had a higher risk of revision compared to tibial cones (P < .01), and sleeves fixed with a hybrid technique were more likely to need revision than cones fixed by the same method (P = .01). CONCLUSIONS: Porous metaphyseal tibial cones and tibial metaphyseal sleeves both performed well at a 41-month median follow-up with no difference in aseptic survivorship between the 2 constructs. Both demonstrate high rates of osseointegration, low rates of aseptic failure, and significant improvement in Knee Society Scores in patients with severe tibial defects in rTKA.

13.
R I Med J (2013) ; 107(5): 7-10, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38687260

ABSTRACT

CASE: We report a rare case of mycobacterial periprosthetic joint infection (PJI) after primary total knee arthroplasty 14 years earlier. Progressive knee pain over three years with a negative PJI infectious workup led to revision total knee arthroplasty. A surprising result was isolation of Mycobacterium avium from tissue cultures taken at time of revision surgery. After six months of antibiotic treatment, the patient is alive with well- functioning pain-free TKA at over one-year follow-up. CONCLUSION: Periprosthetic joint infection can present acutely or chronically years following total knee arthroplasty. Depending on the infecting organism, patients can present with sepsis, or a more indolent slower course that mimics aseptic loosening. In the absence of positive pre-operative labs and cultures, and based on the Musculoskeletal Infection Society (MSIS) criteria, aseptic loosening is a diagnosis of exclusion. An atypical infectious organism should be considered a possible cause and may require specialized cultures of operative specimens.


Subject(s)
Arthroplasty, Replacement, Knee , Prosthesis-Related Infections , Reoperation , Aged , Female , Humans , Male , Anti-Bacterial Agents/therapeutic use , Arthroplasty, Replacement, Knee/adverse effects , Mycobacterium avium/isolation & purification , Mycobacterium avium-intracellulare Infection/diagnosis , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/drug therapy
14.
J Arthroplasty ; 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38640968

ABSTRACT

BACKGROUND: Revision total hip arthroplasty (THA) and total knee arthroplasty (TKA) tremendously burden hospital resources. This study evaluated factors influencing perioperative costs, including emergency department (ED) visits, readmissions, and total costs-of-care within 90 days following revision surgery. METHODS: A retrospective analysis of 772 revision TKAs and THAs performed on 630 subjects at a single center between January 2007 and December 2019 was conducted. Cost data were available from January 2015 to December 2019 for 277 patients. Factors examined included comorbidities, demographic information, preoperative Anesthesia Society of Anesthesiologists score, implant selection, and operative indication using mixed-effects linear regression models. RESULTS: Among 772 revisions (425 THAs and 347 TKAs), 213 patients required an ED visit, and 90 required hospital readmission within 90 days. There were 22.6% of patients who underwent a second procedure after their initial revision. Liver disease was a significant predictor of ED readmission for THA patients (multivariable odds ratio [OR]: 3.473, P = .001), while aseptic loosening, osteolysis, or instability significantly reduced the odds of readmission for TKA patients (OR: 0.368, P = .014). In terms of ED visits, liver disease increased the odds for THA patients (OR: 1.845, P = .100), and aseptic loosening, osteolysis, or instability decreased the odds for TKA patients (OR: 0.223, P < .001). Increased age was associated with increased costs in both THA and TKA patients, with significant cost factors including congestive heart failure for TKA patients (OR: $7,308.17, P = .004) and kidney disease for THA patients. Revision surgeries took longer than primary ones, with TKA averaging 3.0 hours (1.6 times longer) and THA 2.8 hours (1.5 times longer). CONCLUSIONS: Liver disease increases ED readmission risk in revision THA, while aseptic loosening, osteolysis, or instability decreases it in revision TKA. Increased age and congestive heart failure are associated with increased costs. These findings inform postoperative care and resource allocation in revision arthroplasty. LEVEL OF EVIDENCE: Economic and Decision Analysis, Level IV.

15.
Arthroplast Today ; 26: 101340, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38455865

ABSTRACT

Background: In revision total knee arthroplasty, tibial cones have demonstrated improved longevity and reduced incidence of aseptic loosening. Several currently available "off-the-shelf" (OTS) cone systems may not have sizes to accommodate all patient bone morphologies. Methods: Computed tomographies from one hundred primary total knee arthroplasty patients and dimensions of 4 OTS cones were obtained. Press-fit stems were positioned in 3D tibia models to fit the diaphyseal trajectory. Cones were positioned around the stem at 1, 6, and 13 mm resections measured from the trough of the medial tibial plateau, simulating proximal tibial cuts and bone loss. Tibias were examined for cortical breaching following modeled cone preparation. Results: Increased rate of breaching was observed as size and depth of the cone increased. In 2/49 (4.1%) male and 19/46 (41.3%) female tibias, cones could not be positioned without breaching. No breaches were found in 22/49 (45.0%) male and 5/46 (10.9%) female tibias. For every 1 centimeter increase in patient height, odds of breaching decreased by 12% (odds ratio: 0.88, confidence interval: 0.84, 0.92). For every size increase in cone width, odds of breaching increased by 34% (odds ratio: 1.34, confidence interval: 1.28, 1.47). Placing cones deeper also increased breaching compared to the 1 mm cut. Conclusions: In revision total knee arthroplasty, smaller OTS or custom tibial cones may be needed to fit a patient's proximal tibial geometry. This is especially true in patients not accommodated by the OTS cone sizes we tested, which impacted shorter patients and/or those with substantial bone loss requiring more tibial resection and deeper cone placement. Use of smaller or custom tibial cones should be considered where indicated.

16.
J Med Case Rep ; 18(1): 147, 2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38459591

ABSTRACT

BACKGROUND: The transition from revision total knee arthroplasty (RTKA) to arthrodesis involves the replacement of cemented femoral and tibial stems with a modular nail designed for arthrodesis. This conversion process is associated with challenges such as bone loss, blood loss, and prolonged surgical durations. Effectively addressing these complexities through a less invasive surgical approach could be pivotal in enhancing patient outcomes and minimizing associated complications. CASE PRESENTATION: A 75-year-old white Caucasian female patient with a revision total knee arthroplasty (RTKA) performed with a modular uncemented rotating-hinge system, reporting an history of recurrent patellar dislocation, was referred to our institution after a fall resulting in periprosthetic tibial plateau fracture. The fracture was treated with open reduction and internal fixation, but afterwards the patient had been unable to walk again. Tibial stem was mobilized, and extensor mechanism was insufficient due to chronic incomplete quadriceps tendon rupture. The femoral stem was stable, so we decided to convert the rotating-hinge in a arthrodesis with an uncemented modular knee fusion nail maintaining the previous femoral stem. CONCLUSIONS: The result was a successful arthrodesis with minimal bone and blood loss, reduced operative time, and optimal functional outcome at the one-year follow-up. This case highlights the advantage of using a modular knee revision platform system that gives the opportunity to convert a RTKA in arthrodesis.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Female , Aged , Arthroplasty, Replacement, Knee/methods , Reoperation/methods , Knee Joint/surgery , Arthrodesis/methods , Retrospective Studies , Treatment Outcome
17.
Orthop Traumatol Surg Res ; : 103856, 2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38438108

ABSTRACT

Treatment strategies for periprosthetic distal femoral fracture depend on the type of fracture, level with respect to the prosthesis, and prosthesis fixation. The usual treatment is internal fixation by nail or locking plate. This can be more difficult when the fracture is close to the joint, is destabilizing the prosthesis or is associated with reduced bone stock, and implant exchange should be considered, depending on the patient's health status. The aim is to obtain the fastest possible recovery while limiting complications and minimizing surgery time for often frail and elderly patients. The present study details the implant revision technique in periprosthetic distal femoral fracture, which requires experience in traumatology and prosthetic revision and material adapted to the situation. LEVEL OF EVIDENCE: V, expert opinion.

18.
Article in English | MEDLINE | ID: mdl-38504019

ABSTRACT

INTRODUCTION: The purpose of this retrospective study was to compare the medium-term clinical and radiographic outcomes of two series of patients treated for revision TKA: one implanted with trabecular metal (TM) augments and one implanted with classic titanium augments. MATERIALS AND METHODS: A total of 85 patients with a type 2 AORI defect underwent revision TKA and were treated either with TM epiphyseal augments directly screwed in the bone or with traditional titanium augments. There were 46 patients in the TM group and 39 patients in the titanium group included in the study. All the patients received the same varus-valgus constrained implant and no metaphyseal fixation devices were used. RESULTS: After a mean follow-up of 66.4 months, no statistically significant difference was observed in terms of failure for aseptic loosening between the two groups (4% in the TM group and 7.8% in the titanium group, p = 0.35). The ten-year survival using aseptic loosening as endpoint was 90.5% (95% CI 94.1-98.6) in the TM group and 85% (95% CI 101.9-119.3) in the titanium group (p = 0.26). A statistically significant difference was detected for the presence of RLL. No RLL were found under the studied TM augments compared to 13.7% of the titanium augments (p = 0.01). CONCLUSION: The use of TM augments directly screwed to the epiphysis of the femur and the tibia reduced the incidence of RLL compared to standard titanium augments during revision TKA with promising medium-term results.

19.
Arch Orthop Trauma Surg ; 144(4): 1703-1712, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38488903

ABSTRACT

INTRODUCTION: There are two variants regarding the low location of the patella in relation to the tibio-femoral joint line: patella baja (PB) and pseudo-patella baja (PPB). The purpose of this study is to investigate the incidence of PB and PPB in a cohort of patients that underwent revision total knee arthroplasty (rTKA) for aseptic reasons and describe any differences in each group's ROM. METHODS: This retrospective study included 114 patients that underwent aseptic revision TKA surgery between 2017 and 2022. Patients were revised either for stiffness (Group 1) or aseptic loosening/instability (Group 2). The Insall-Salvati ratio (ISR) and Blackburne-Peel ratio (BPR) were used to evaluate the patellar position. ISR < 0.8 defined PB, while cases with ISR ≥ 0.8 and BPI < 0.54 were defined as PPB. ROM was measured and a subanalysis was conducted to investigate the progression of the values of ISR and BPR. RESULTS: 55 patients comprised Group 1, and 59 patients comprised Group 2. Overall, 13 cases (11.4%) had PB before rTKA and 24 (21%) had PB after rTKA. Cases with PPB were 13 (11.4%) before and 34 (29.9%) after rTKA. Group 1 patients presented with more PB before and after rTKA (12.8% vs 10.2% and 27.3% vs 15.2% respectively). However, after rTKA Group 1 patients presented with less PPB (20%) compared to Group 2 (39%) (p = 0.02). In Group 1, patients with PPB after rTKA had less ROM compared to those without PPB [83.2 (± 21.9) vs 102.1 (± 19.9) (p = 0.025)]. The subanalysis (69 patients) showed a statistically significant decrease in ISR before and after rTKA (p = 0.041), and from the native knee to post-rTKA (p = 0.001). There was a statistically significant decrease in BPR before and after rTKA (p = 0.001) and from the native knee to both pre- and post-rTKA (p < 001). CONCLUSION: After undergoing rTKA, the incidences of both patella baja (PB) and pseudo-patella baja (PPB) increased. Stiffness in the knee was associated with a higher incidence of PB, while non-stiffness cases showed a significantly higher incidence of PPB. Patients with stiff knees and PPB after rTKA experienced a significant reduction in range of motion (ROM). Additionally, the study revealed a noteworthy decrease in ISR and BPR with each subsequent surgery. This information is crucial for healthcare providers, as it sheds light on potential risks and outcomes of rTKA, allowing for improved patient management and surgical decision-making. LEVEL OF EVIDENCE: III.


Subject(s)
Arthroplasty, Replacement, Knee , Joint Diseases , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/adverse effects , Patella/surgery , Incidence , Retrospective Studies , Knee Joint/surgery , Joint Diseases/surgery , Range of Motion, Articular , Knee Prosthesis/adverse effects
20.
Arthroplast Today ; 25: 101271, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38304246

ABSTRACT

Background: No objective radiographic scoring system exists to classify metaphyseal cone stability. Our purpose was to create a novel, systematic method to radiographically evaluate metaphyseal cone fixation based on radiographic findings suggestive of cone stability. Methods: A retrospective analysis was conducted of revision total knee arthroplasty patients (6/2015-12/2017) using porous titanium femoral or tibial metaphyseal cones in conjunction with short cemented stems (50 mm-75 mm). Minimum follow-up was 2 years. Survivorship free of aseptic loosening and reoperation, as well as radiographic evaluation using a novel cone zone scoring system were analyzed. Results: Forty-nine revision total knee arthroplasties were included in the study (12 femoral, 48 tibial cones), the majority, performed for aseptic loosening (25/49, 51%). Median follow-up was 39 months (range 25-58). Using the radiographic cone zone scoring method, >90% of all femoral cones were classified as likely stable or stable with strong, statistically significant intraclass correlations between all 3 reviewers. Similarly, >97% of all tibial cones were classified as likely stable or stable, with moderate, statistically significant intraclass correlations between all 3 reviewers. Only 1 femoral and 1 tibial cone were considered at risk of loosening. The study sample demonstrated 100% survivorship free of revision for aseptic loosening without evidence of radiographic loosening in any case. Conclusions: Using a novel systematic cone zone scoring and classification method, the overwhelming majority of femoral and tibial cones were classified as likely stable or stable, with no identified cases of aseptic loosening or related revision. Further studies are needed to validate this objective classification method.

SELECTION OF CITATIONS
SEARCH DETAIL
...