Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 229
Filter
1.
Orthop Surg ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38982614

ABSTRACT

Pedicle screw loosening after posterior lumbar fusion is associated with poor bone quality, which often determines screw pull-out strength, insertion torque, and vertebral body loading characteristics. Magnetic resonance imaging (MRI)-based vertebral bone quality (VBQ) score were associated with poor bone quality. Current evidence suggests that pedicle bone quality (PBQ) has a greater impact on screw stability. However, the correlation between MRI-based PBQ score and screw loosening has not been reported. PURPOSE: To introduce and evaluate an MRI-based PBQ score to determine its effectiveness in predicting pedicle screw loosening following lumbar fusion surgery. METHODS: The retrospective study analyzed 244 patients who underwent posterior lumbar interbody fusion (PLIF) with pedicle screws between December 2017 and December 2021, with CT and MRI imaging before surgery. Data collected included patient demographics and preoperative radiological data. Radiographic screw loosening was measured at 12 months postoperatively. Clinical assessments included pain visual analog scale (VAS) and Oswestry Disability Index (ODI) scores. The PBQ score was measured using MRI scans. We use univariate analysis for preliminary screening of the risk factors of screw loosening. Subsequent analysis involved multivariate logistic regression to identify independent predictive factors for screw loosening. We constructed the receiver operating characteristic (ROC) curve to ascertain the discriminative capacity of the PBQ score. The area under the curve (AUC) quantified its predictive accuracy. Additionally, we evaluated the association between PBQ score and screw loosening using Spearman's correlation analysis. RESULTS: Overall, 244 patients who underwent PLIF with pedicle screw fixation participated in this study, including 35 in the loosening group and 209 in the non-loosening group. PBQ score in the loosening group was significantly higher than that in the non-loosening group. On multivariate logistic regression, the higher PBQ score (OR = 8.481, 95% CI: 3.158-22.774; p < 0.001) and the lower mean Hounsfield unit (HU) value of L1-4 (OR = 0.967, 95% CI 0.951-0.984; p < 0.001) were the variables that significantly predicted screw loosening. The AUC for the PBQ score and HU value were 0.751 (95% CI: 0.673-0.828) and 0.702 (95% CI: 0.612-0.791). The PBQ score optimal cutoff to differentiate patients with loosening and with non-loosening was calculated as 3.045 with a sensitivity of 85.7% and specificity of 76.9%, while the optimal cutoff of the HU value was 151.5 with a sensitivity of 64.6% and specificity of 89.5%. CONCLUSIONS: The association between the PBQ score and the propensity for lumbar pedicle screw loosening was found to be substantial. As a predictive measure, the PBQ score outperformed the HU value in forecasting the likelihood of screw loosening post-posterior lumbar fusion.

2.
BMC Musculoskelet Disord ; 25(1): 516, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38970034

ABSTRACT

BACKGROUND: Sacral screw loosening is a typical complication after internal fixation surgery through the vertebral arch system. Bicortical fixation can successfully prevent screw loosening, and how improving the rate of bicortical fixation is a challenging clinical investigation. OBJECTIVE: To investigate the feasibility of improving the double corticality of sacral screws and the optimal fixation depth to achieve double cortical fixation by combining the torque measurement method with bare hands. METHODS: Ninety-seven cases of posterior lumbar internal fixation with pedicle root system were included in this study. Based on the tactile feedback of the surgeon indicating the expected penetration of the screw into the contralateral cortex of the sacrum, the screws were further rotated by 180°, 360°, or 720°, categorized into the bicortical 180° group, bicortical 360° group, and bicortical 720° group, respectively. Intraoperatively, the torque during screw insertion was recorded. Postoperatively, the rate of double-cortex engagement was evaluated at 7 days, and screw loosening was assessed at 1 year follow-up. RESULTS: The bicortical rates of the 180° group, 360° group, and 720° group were 66.13%, 91.18% and 93.75%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05).The rates of loosening of sacral screws in the 180° group, 360° group, and 720° group were 20.97%, 7.35% and 7.81%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05). The bicortical 360° group achieved a relatively satisfactory rate of dual cortical purchase while maintaining a lower rate of screw loosening. CONCLUSION: Manual insertion of sacral screws with the assistance of a torque measurement device can achieve a relatively satisfactory dual cortical purchase rate while reducing patient hospitalization costs.


Subject(s)
Bone Screws , Lumbar Vertebrae , Sacrum , Spinal Fusion , Torque , Humans , Male , Female , Sacrum/surgery , Sacrum/diagnostic imaging , Middle Aged , Aged , Spinal Fusion/instrumentation , Spinal Fusion/methods , Spinal Fusion/adverse effects , Lumbar Vertebrae/surgery , Adult , Feasibility Studies , Treatment Outcome , Follow-Up Studies
3.
Neurospine ; 21(2): 712-720, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38955540

ABSTRACT

OBJECTIVE: To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value. METHODS: A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1-4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL). RESULTS: A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1-4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552-8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%). CONCLUSION: The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.

4.
Int J Spine Surg ; 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38866586

ABSTRACT

BACKGROUND: Various strategies have been used to reduce pedicle screw loosening following lumbar instrumented fusion, but all strategies have limitations. In this prospective multicenter cohort study, outcomes of elderly patients with reduced bone density who underwent primary or revision fusion surgery using a novel technique of pedicle screw augmentation with demineralized bone fiber (DBF) anchors were evaluated. METHODS: This study included elderly patients (aged >65 years) with dual-energy x-ray absorptiometry-confirmed reduced bone density who required lumbar pedicle screw fixation and were treated with supplemental DBF allograft anchors during primary or revision surgery. The need for DBF anchors was determined by evaluating preoperative computed tomography (CT) scans (for revision surgery) and by the surgeons' tactile feedback intraoperatively during pedicle screw insertion and removal. After determining the pedicle screw void diameter with a sizing instrument, DBF anchors and pedicle screws of the same diameter were placed into the void. CT scans were obtained on postoperative day 2 to assess pedicle breach, pedicle fracture, or anchor material extrusion and at 6 and 12 months postoperatively to assess screw loosening. Thereafter, to minimize radiation exposure, CT scans were only performed for recurrence of pain. RESULTS: Twenty-three patients (79% women; mean age, 74 years) received 50 lumbosacral pedicle screws augmented with DBF anchors. Most surgeries (n = 18, 78%) were revisions, and most anchors were inserted into revision pedicle screw trajectories (n = 33, 66%). Day-2 CT scans revealed no pedicle breach/fracture or extrusion of anchor material. During a mean follow-up of 15 months (12-20 months), no screw loosening was detected, and no patient required pedicle screw revision surgery. There were no adverse events attributable to DBF allografts. CONCLUSIONS: DBF allograft anchors appear to be safe and effective for augmenting pedicle screws during revision surgeries in female elderly patients with reduced bone density. CLINICAL RELEVANCE: Clinically, DBF reduced the rate of pedicle screw loosening in patients with reduced bone density. A significant reduction in screw loosening can decrease the need for revision surgeries, which are costly and carry additional risks. Enhanced bone integration from the DBF may promote better healing and long-term stability.

5.
Orthop Surg ; 16(7): 1718-1725, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38766934

ABSTRACT

OBJECTIVE: Screw loosening is a common complication of internal fixation of pedicle screw. Therefore, the development of a pedicle screw with low loosening rate and high biosafety is of great clinical significance. This study aimed to investigate whether the application of a porous scaffold structure can improve the stability of pedicle screws by comparing the biomechanical properties of novel porous scaffold core pedicle screws (PSCPSs) with those of hollow lateral hole pedicle screws (HLHPSs) in a porcine lumbar spine. METHODS: Thirty-two pedicle screws of both types were implanted bilaterally into the L1-4 vertebrae of four Bama pigs, with our newly designed PSCPSs on the right and HLHPSs on the left. All the Bama pigs were sacrificed 16 weeks postoperatively, and the lumbar spine was freed into individual vertebrae. Biomechanical properties of both the pedicle screws were evaluated using pull-out tests, as well as cyclic bending and pull-out tests, while the mechanical properties were assessed using three-point bending tests. The data generated were statistically analyzed using paired-sample t-tests and two independent sample t-tests. RESULTS: We found that the maximal pull-out forces before and after cyclic bending of the PSCPSs (1161.50 ± 337.98 N and 1075.25 ± 223.33 N) were significantly higher than those of the HLHPSs (948.38 ± 194.32 N and 807.13 ± 242.75 N) (p < 0.05, p < 0.05). In 800 cycles of the bending tests, neither PSCPS nor HLHPS showed loosening or visible detachment, but their maximal pull-out forces after cyclic bending tests decreased compared to those in cycles without cyclic bending tests (7.43% and 14.89%, respectively), with no statistical significance (p > 0.05 and p > 0.05, respectively). Additionally, both screws buckled rather than broke in the three-point bending tests, with no statistically significant differences between the maximal bending load and modulus of elasticity of the two screws (p > 0.05 and p > 0.05, respectively). CONCLUSIONS: Compared with the HLHPSs, the PSCPSs have greater pull-out resistance and better fatigue tolerance with appropriate mechanical properties. Therefore, PSCPSs theoretically have significant potential for clinical applications in reducing the incidence of loosening after pedicle screw implantation.


Subject(s)
Lumbar Vertebrae , Pedicle Screws , Animals , Swine , Biomechanical Phenomena , Lumbar Vertebrae/surgery , Porosity , Materials Testing
6.
BMC Musculoskelet Disord ; 25(1): 418, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807200

ABSTRACT

BACKGROUND: It was reported the paraspinal muscle played an important role in spinal stability. The preoperative paraspinal muscle was related to S1 screw loosening. But the relationship between preoperative and postoperative change of psoas major muscle (PS) and S1 pedicle screw loosening in degenerative lumbar spinal stenosis (DLSS) patients has not been reported. This study investigated the effects of preoperative and follow-up variations in the psoas major muscle (PS) on the first sacral vertebra (S1) screw loosening in patients with DLSS. METHODS: 212 patients with DLSS who underwent lumbar surgery were included. The patients were divided into the S1 screw loosening group and the S1 screw non-loosening group. Muscle parameters were measured preoperatively and at last follow-up magnetic resonance imaging. A logistic regression analysis was performed to investigate the risk factors for S1 screw loosening. RESULTS: The S1 screw loosening rate was 36.32% (77/212). The relative total cross-sectional areas and relative functional cross-sectional areas (rfCSAs) of the PS at L2-S1 were significantly higher after surgery. The increased rfCSA values of the PS at L3-S1 in the S1 screw non-loosening group were significantly higher than those in the S1 screw loosening group. The regression analysis showed male, lower CT value of L1 and longer segment fusion were independent risk factors for S1 screw loosening, and postoperative hypertrophy of the PS was a protective factor for S1 screw loosening. CONCLUSIONS: Compared to the preoperative muscle, the PS size increased and fatty infiltration decreased after surgery from L2-3 to L5-S1 in patients with DLSS after short-segment lumbar fusion surgery. Postoperative hypertrophy of the PS might be considered as a protective factor for S1 screw loosening. MRI morphometric parameters and postoperative selected exercise of PS for DLSS patients after posterior lumbar fusion surgery might contribute to improvement of surgical outcome.


Subject(s)
Lumbar Vertebrae , Pedicle Screws , Psoas Muscles , Spinal Fusion , Spinal Stenosis , Humans , Male , Spinal Stenosis/surgery , Spinal Stenosis/diagnostic imaging , Female , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Aged , Psoas Muscles/diagnostic imaging , Middle Aged , Follow-Up Studies , Spinal Fusion/instrumentation , Spinal Fusion/adverse effects , Magnetic Resonance Imaging , Sacrum/diagnostic imaging , Sacrum/surgery , Retrospective Studies , Risk Factors , Aged, 80 and over , Preoperative Period
7.
Orthop Surg ; 16(6): 1461-1472, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38714346

ABSTRACT

OBJECTIVES: It is now understood that pedicle screw loosening at the implant-bone interface can lead to poor screw-bone interface purchase and decreased fixation stability. Previous biomechanical tests used cadaveric vertebrae and pull-out or torque loads to assess the effect of the insertional direction of pedicle screws on screw loosening. However, these tests faced challenges in matching biomechanical differences among specimens and simulating in vivo loads applied on pedicle screws. This study aimed to evaluate the effect of the insertional direction of pedicle screws on screw loosening using tension-compression-bending loads and synthetic bone vertebrae. METHODS: Polyaxial pedicle screws were inserted into nine synthetic bone vertebrae in three directions (three samples per group): cranial, parallel, and caudad (-10°, 0°, +10° of the pedicle screw rod to the upper plane of the vertebra, respectively). Pedicle screws in the vertebrae were loaded using a polyethylene block connected to a material testing machine. Tension-compression-bending loads (100N-250N) with 30,000 cycles were applied to the pedicle screws, and displacements were recorded and then cycle-displacement curve was drawn based on cycle number. Micro-CT scans were performed on the vertebrae after removing the pedicle screws to obtain images of the screw hole, and the screw hole volume was measured using imaging analysis software. Direct comparison of displacements was conducted via cycle-displacement curve. Screw hole volume was analyzed using analysis of variance. The correlation between the displacement, screw hole volume and the direction of pedicle screw was assessed by Spearman correlation analysis. RESULTS: The smallest displacements were observed in the caudad group, followed by the parallel and cranial groups. The caudad group had the smallest screw hole volume (p < 0.001 and p = 0.009 compared to the cranial and parallel groups, respectively), while the volume in the parallel group was greater than that in the cranial group (p = 0.003). Correlation analysis revealed that the insertional direction of the pedicle screw was associated with the displacement (p = -0.949, p < 0.001) and screw hole volume (p = -0.944, p < 0.001). CONCLUSION: Strong correlations were found between the insertional direction of the pedicle screw and relevant parameters, including displacement and screw hole volume. Pedicle screw insertion in the caudad direction resulted in the least pedicle screw loosening.


Subject(s)
Pedicle Screws , Biomechanical Phenomena , Humans , Materials Testing , Prosthesis Failure , Spine/surgery , X-Ray Microtomography
8.
Article in English | MEDLINE | ID: mdl-38808689

ABSTRACT

The treatment of Giant Cell Tumor (GCT) in the distal radius poses challenges due to the intricate anatomical features of the bone. It often necessitates the use of long implant plates or the interconnection of multiple short plates after tumor excision. However, the deployment of metal plates may increase the risk of screw loosening and various complications. To address these challenges, this study proposes the adoption of carbon fiber-reinforced PEEK (CFRP) as the base material. As a unique strategy, performance parameters (PP) were developed to compare CFRP implant plates with a Ti-6Al-4V plate using the Finite-element Method. The focus was on four elements: the screw axial force, bone growth, callus formation, and bone resorption. The investigation into the screw axial force involved analyzing the internal force of the screw. The remaining parameters were evaluated using the stress, strain, or elastic energy induced in the bones. The findings showed that the second screw endured the largest screw axial force, measuring 10.16 N under a 90-degree 10-N loading at the translocated bone. The model without a callus exerted a significantly greater force on the screw than the model with a callus, leading to screw loosening in the early stage of treatment. The maximum PP, reached 1.62, was achieved with an angle-ply [456/-456] laminate, featuring a weighting fraction of 0.7 for bone growth and 0.1 for the other parameters. This study provides a generalized methodology for assessing the performances of CFRP implants and offers guidelines for future development in composite implant plate technology.

9.
Int J Spine Surg ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38744483

ABSTRACT

BACKGROUND: Atlantoaxial transarticular fixation, also called the Magerl technique, is said to be the most robust biomechanical method of fixation of the atlantoaxial vertebrae. However, the procedure carries a risk of spinal cord and vertebral artery injury during the insertion process, especially in patients with a high-riding vertebral artery. In this study, a computed tomography (CT)-based navigation system was used for preoperative planning and insertion. This investigation sought to determine the rate and direction of screw perforation as well as the incidence of screw loosening in computer-assisted atlantoaxial transarticular fixation. METHODS: Sixty patients (31 men and 29 women; mean ± SD age: 65.3 ± 19.6 years) who received atlantoaxial transarticular screw insertion with preoperative CT navigation were analyzed. We investigated screw position and loosening by CT at the final follow-up. RESULTS: Of the 108 screws inserted, the rate of Grade 2 or higher perforation was 4.6% (5/108). Nine of 81 (11.1%) screws inserted into the 44 patients who were followed for at least 6 months showed loosening. Logistic regression analysis revealed that unilateral insertion (odds ratio: 8.50, 95% confidence interval: 1.53-47.2, P = 0.014) was significantly associated with the incidence of screw loosening. CONCLUSIONS: The screw perforation rate of Grade 2 or higher in computer-assisted atlantoaxial transarticular screw fixation was 4.6%, with comparable frequencies of perforation direction. Unilateral insertion was a significant independent factor associated with screw loosening, which occurred in 11.1% of insertions. CLINICAL RELEVANCE: Spine surgeons should follow up with patients with caution because screws with unilateral insertion are prone to loosening.

10.
Spine J ; 2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38685274

ABSTRACT

BACKGROUND CONTEXT: MRI-based vertebral bone quality (VBQ) score is an effective predictor of pedicle screw loosening after lumbar fusion surgery and has been recognized as a valuable tool for assessing preoperative bone quality. Due to the lateral curvature of lumbar spine of degenerative scoliosis, accurate measurement of VBQ score by conventional measurement methods that capture MRI signal intensity at L1-4 may be limited under certain conditions. To this end, a new simplified S1 VBQ score method has been proposed, which is comparable to the previous L1-4 VBQ score or S1 Hounsfield unit (HU) value, and has high accuracy and reliability. PURPOSE: To evaluate the predictive value of MRI-based S1 VBQ score for pedicle screw loosening following surgery for adult degenerative scoliosis (ADS). STUDY DESIGN/SETTING: Retrospective single-center cohort. PATIENT SAMPLE: We reviewed 92 patients who underwent posterior lumbar interbody fusion (PLIF) with pedicle screw fixation for ADS between January 2017 and January 2020. OUTCOME MEASURES: Association between S1 VBQ score and pedicle screw loosening following surgery for ADS. METHODS: We retrospectively reviewed the records of all patients who performed PLIF between January 2017 and January 2020. The clear zone around pedicle screws≥1 mm can be identified as screw loosening. The S1 VBQ score is calculated from the S1 central-based non-contrast T1-weighted magnetic resonance imaging (MRI). The signal intensity (SI) of the cerebrospinal fluid (CSF) was then measured using ROI placed at the L3 level to normalize the results. Multivariate logistic regression analysis was performed to identify independent risk factors for screw loosening. Then, constructed a receiver operating characteristic (ROC) curve and determined the threshold (cut-off) of VBQ score with high sensitivity and specificity based on Youden Index. RESULTS: A total of 92 patients were included, including 34 males and 58 females. The mean age of the patients was 61.23±1.23 years old. At 1-year follow-up, the screw loosening rate was 56.5% (52/92). The age and levels of fixation were higher in the loosening group than in the non-loosening group (p=.036, p=.025). Patients in the loosening group had a greater VBQ score compared to patients in the non-loosening group (3.31±0.41 vs 3.01±0.28, p=.001). Multivariate logistic regression analysis showed that advanced age (OR, 1.090; 95% CI 1.005-1.183; p=.039) and higher VBQ score (OR, 5.778; 95% CI 2.889-16.177; p=.001) were independent risk factors for screw loosening. In addition, the ROC curve were created to assess the role of VBQ score as predictors of screw loosening with a diagnostic accuracy of 74.6% (95% CI 64.2%-85.1%).The most suitable threshold for the VBQ score as determined by the Youden Index was 3.175 (sensitivity: 76.0%, specificity: 83.3%). CONCLUSIONS: Higher S1 VBQ score was significantly associated with pedicle screw loosening following surgery for ADS. The S1 VBQ score can be used as an effective preoperative predictor, which has the potential clinical application.

11.
J Prosthodont Res ; 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38616127

ABSTRACT

PURPOSE: This study aimed to investigate whether the presence of a mesial cantilever influences the biomechanical behavior and screw loosening in fixed partial dentures (FPDs) with a distally tilted implant in the atrophic posterior maxilla and where to best place the distal implant. METHODS: Two configurations of implant-supported four-unit FPDs were modelled using finite element analysis. Five interabutment distances were considered. The stress and strain distributions in the implants, abutments, and prosthetic screws were verified under occlusal loading. The development of the axial force on the abutments and screws was also examined. Two-sample t-tests were used to identify differences (P < 0.05). RESULTS: The von Mises stress distributions of the components in the two configurations were similar, as were the maximum plastic strains of the distal prosthetic screws, distal implants, and 30° abutments. The difference in the maximum plastic strains of the straight abutments was statistically significant. The preload of the 30° abutment screws was significantly reduced after the initial loading. In the absence of a mesial cantilever, the axial force on the straight abutments increased. However, when a mesial cantilever was used, the preload of the straight abutments was maintained, and the axial force on the prosthetic screws fluctuated less. The axial force fluctuation of the abutments gradually decreased as the interabutment distance increased. CONCLUSIONS: Mesial cantilever usage had minimal effect on stress or strain distribution in FPD implants, abutments, or prostheses. However, it helped resist screw loosening. The distal screw access hole was preferably positioned close to the prosthetic end.

12.
Eur Spine J ; 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38619634

ABSTRACT

INTRODUCTION: Despite modern fixation techniques, spinopelvic fixation failure (SPFF) after adult spinal deformity (ASD) surgery ranges from 4.5 to 38.0%, with approximately 50% requiring reoperation. Compared to other well-studied complications after ASD surgery, less is known about the incidence and predictors of SPFF. AIMS/OBJECTIVES: Given the high rates of SPFF and reoperation needed to treat it, the purpose of this systematic review and meta-analysis was to report the incidence and failure mechanisms of SPF after ASD surgery. MATERIALS/METHODS: The literature search was executed across four databases: Medline via PubMed and Ovid, SPORTDiscus via EBSCO, Cochrane Library via Wiley, and Scopus. Study inclusion criteria were patients undergoing ASD surgery with spinopelvic instrumentation, report rates of SPFF and type of failure mechanism, patients over 18 years of age, minimum 1-year follow-up, and cohort or case-control studies. From each study, we collected general demographic information (age, gender, and body mass index), primary/revision, type of ASD, and mode of failure (screw loosening, rod breakage, pseudarthrosis, screw failure, SI joint pain, screw protrusion, set plug dislodgment, and sacral fracture) and recorded the overall rate of SPF as well as failure rate for each type. For the assessment of failure rate, we required a minimum of 12 months follow-up with radiographic assessment. RESULTS: Of 206 studies queried, 14 met inclusion criteria comprising 3570 ASD patients who underwent ASD surgery with pelvic instrumentation (mean age 65.5 ± 3.6 years). The mean SPFF rate was 22.1% (range 3-41%). Stratification for type of failure resulted in a mean SPFF rate of 23.3% for the pseudarthrosis group; 16.5% for the rod fracture group; 13.5% for the iliac screw loosening group; 7.3% for the SIJ pain group; 6.1% for the iliac screw group; 3.6% for the set plug dislodgement group; 1.1% for the sacral fracture group; and 1% for the iliac screw prominence group. CONCLUSION: The aggregate rate of SPFF after ASD surgery is 22.1%. The most common mechanisms of failure were pseudarthrosis, rod fracture, and iliac screw loosening. Studies of SPFF remain heterogeneous, and a consistent definition of what constitutes SPFF is needed. This study may enable surgeons to provide patient specific constructs with pelvic fixation constructs to minimize this risk of failure.

13.
J Prosthodont ; 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38512996

ABSTRACT

PURPOSE: Complications can and do occur with implants and their restorations with causes having been proposed for some single implant complications but not for others. METHODS: A review of pertinent literature was conducted. A PubMed search of vibration, movement, and dentistry had 175 citations, while stress waves, movement, and dentistry had zero citations as did stress waves, movement. This paper discusses the physics of vibration, elastic and inelastic collision, and stress waves as potentially causative factors related to clinical complications. RESULTS: Multiple potential causes for interproximal contact loss have been presented, but it has not been fully understood. Likewise, theories have been suggested regarding the intrusion of natural teeth when they are connected to an implant as part of a fixed partial denture as well as intrusion when a tooth is located between adjacent implants, but the process of intrusion, and resultant extrusion, is not fully understood. A third complication with single implants and their crowns is abutment screw loosening with several of the clinical characteristics having been discussed but without determining the underlying process(es). CONCLUSIONS: Interproximal contact loss, natural tooth intrusion, and abutment screw loosening are common complications that occur with implant retained restorations. Occlusion is a significant confounding variable. The hypothesis is that vibration, or possibly stress waves, generated from occlusal impact forces on implant crowns and transmitted to adjacent teeth, are the causative factors in these events. Since occlusion appears to play a role in these complications, it is recommended that occlusal contacts provide centralized stability on implant crowns and not be located on any inclined surfaces that transmit lateral forces that could be transmitted to an adjacent tooth and cause interproximal contact loss or intrusion. The intensity, form, and location of proximal contacts between a natural tooth located between adjacent single implant crowns seem to play a role in the intrusion of the natural tooth. Currently, there is a lack of information about the underlying mechanisms related to these occurrences and research is needed to define any confounding variables.

14.
Ther Clin Risk Manag ; 20: 185-194, 2024.
Article in English | MEDLINE | ID: mdl-38496352

ABSTRACT

Purpose: We conducted a longitudinal study to examine the predictive role of risk factors in the occurrence of pedicle screw loosening, assessed through pre- and post-operative computed tomography (CT) scans. Methods: A total of 103 patients with degenerative lumbar disease who had undergone L4/5 pedicle screw fixation (involving 412 screws) were included in this study. They were subsequently categorized into two groups-the "loosening group" and the "non-loosening group". The axial and sagittal angles of the screw trajectory in pre- and post-operative CT images were measured, and the deviation angles were computed. Additionally, measurements were taken of the Hounsfield unit (HU) within the screw entry point area, the pedicle, and the vertebral body in preoperative CT images. Logistic regression analysis was employed to ascertain the risk factors influencing the occurrence of screw loosening. Results: Elderly patients who experienced screw loosening tended to have bilateral screw issues at the L5 level (p < 0.005). The HU of the pedicle (p < 0.001), age (p < 0.001), and the axial deviation angle (p = 0.014) were identified as independent factors predicting screw loosening. Additionally, when HU of the pedicle < 126.5 or age ≥ 53.5 years, the axial deviation angle was found to be smaller in the group experiencing screw loosening (p = 0.018 and p = 0.019). Conclusion: Loosening of screws positioned at L5 was found to be more prevalent in elderly patients, particularly exhibiting a bilateral occurrence. Independent predictors of this phenomenon included a low HU value in the pedicle, advanced age in patients, and a substantial axial deviation angle. In the case of elderly patients with a low HU value in the pedicle, a reduced axial surgical deflection was necessitated to prevent the occurrence of screw loosening.

15.
Article in English | MEDLINE | ID: mdl-38498785

ABSTRACT

PURPOSE: This study aimed to identify the technical complications associated with maxillary complete-arch implant-supported fixed prostheses (ISFPs) and to evaluate the survival rates of both implants and prostheses. Additionally, we sought to analyze the impact of the presence of cantilevers, the type of prosthetic abutment, and the number of implants on the occurrence of complications. MATERIALS AND METHODS: Data were obtained from standardized clinical assessments carried out in a single appointment by two calibrated professionals using information from dental records. RESULTS: The sample consisted of 64 patients rehabilitated with ISFPs classified as hybrid prostheses (metal-resin). The survival rate for implants was 98.6% after 1 to 12 years (5.2 years ± 36.6 months) and was 100% for the prostheses after a follow-up period of 12 to 144 months (mean 48.1 ± 33.94 months). The most frequent complications were occlusal wear (82.8% of patients) and loosening of prosthetic screws (16.6%) and abutments (8.1%). Screw loosening frequency was significantly greater in 30-degree abutments compared with straight abutments (P=0.008), but no significant difference was found between 17-degree and 30-degree abutments. Prostheses with a higher occurrence of screw loosening had a greater average CL/AP spread ratios (0.9 ô€€€ 0.5). In addition, abutments installed on distal implants were more likely to loosen (P<0.001). The absence of mutually protected occlusion did not significantly influence the loosening of screws and prosthetic abutments. CONCLUSIONS: Implantsupported fixed maxillary complete-arch rehabilitations have high survival rates but are subject to technical complications.

16.
Biosci Trends ; 18(1): 83-93, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38417874

ABSTRACT

The adequacy of screw anchorage is a critical factor in achieving successful spinal fusion. This study aimed to use machine learning algorithms to identify critical variables and predict pedicle screw loosening after degenerative lumbar fusion surgery. A total of 552 patients who underwent primary transpedicular lumbar fixation for lumbar degenerative disease were included. The LASSO method identified key features associated with pedicle screw loosening. Patient clinical characteristics, intraoperative variables, and radiographic parameters were collected and used to construct eight machine learning models, including a training set (80% of participants) and a test set (20% of participants). The XGBoost model exhibited the best performance, with an AUC of 0.884 (95% CI: 0.825-0.944) in the test set, along with the lowest Brier score. Ten crucial variables, including age, disease diagnosis: degenerative scoliosis, number of fused levels, fixation to S1, HU value, preoperative PT, preoperative PI-LL, postoperative LL, postoperative PT, and postoperative PI-LL were selected. In the prospective cohort, the XGBoost model demonstrated substantial performance with an accuracy of 83.32%. This study identified crucial variables associated with pedicle screw loosening after degenerative lumbar fusion surgery and successfully developed a machine learning model to predict pedicle screw loosening. The findings of this study may provide valuable information for clinical decision-making.


Subject(s)
Pedicle Screws , Spinal Fusion , Humans , Prospective Studies , Spinal Fusion/adverse effects , Spinal Fusion/methods , Retrospective Studies , Treatment Outcome
17.
Asian Spine J ; 18(1): 137-145, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38379148

ABSTRACT

The purpose of this study was to assess the factors affecting caudal screw loosening after spinopelvic fixation for adult patients with spinal deformity. This meta-analysis calculated the weighted mean difference (WMD) and odds ratio (OR) using Review Manager ver. 5.3 (RevMan; Cochrane, London, UK). The loosening group was older than the control group (WMD, 2.17; 95% confidence interval [CI], 0.48-3.87; p=0.01). The S2 alar-iliac (S2AI) could prevent the caudal screw from loosening (OR, 0.43; 95% CI, 0.20-0.94; p=0.03). However, gender distribution (p=0.36), the number of fusion segments (p=0.24), rod breakage (p=0.97), T-score (p=0.10), and proximal junctional kyphosis (p=0.75) demonstrated no difference. Preoperatively, only pelvic incidence (PI) in the loosening group was higher (WMD, 5.08; 95% CI, 2.71-7.45; p<0.01), while thoracic kyphosis (p=0.09), lumbar lordosis (LL) (p=0.69), pelvic tilt (PT) (p=0.31), pelvic incidence minus lumbar lordosis (PI-LL) (p=0.35), sagittal vertical axis (SVA) (p=0.27), and T1 pelvic angle (TPA) demonstrated no difference (p=0.10). PI-LL (WMD, 6.05; 95% CI, 0.96-11.14; p=0.02), PT (WMD, 4.12; 95% CI, 0.99-7.26; p=0.01), TPA (WMD, 4.72; 95% CI, 2.35-7.09; p<0.01), and SVA (WMD, 13.35; 95% CI, 2.83-3.87; p=0.001) were higher in the screw loosening group immediately postoperatively. However, TK (p=0.24) and LL (p=0.44) demonstrated no difference. TPA (WMD, 8.38; 95% CI, 3.30-13.47; p<0.01), PT (WMD, 6.01; 95% CI, 1.47-10.55; p=0.01), and SVA (WMD, 23.13; 95% CI, 12.06-34.21; p<0.01) were higher in the screw loosening group at the final follow-up. However, PI-LL (p=0.17) demonstrated no significant difference. Elderly individuals were more susceptible to the caudal screw loosening, and the S2AI screw might better reduce the caudal screw loosening rate than the iliac screws. The lumbar lordosis and sagittal alignment should be reconstructed properly to prevent the caudal screw from loosening. Measures to block sagittal alignment deterioration could also prevent the caudal screw from loosening.

18.
World Neurosurg ; 184: e129-e136, 2024 04.
Article in English | MEDLINE | ID: mdl-38253180

ABSTRACT

OBJECTIVE: To investigate S2 alar screw (S2AS) accuracy and factors associated with S2AS loosening and lumbosacral nonunion. METHODS: We retrospectively reviewed patients who underwent lumbosacral fusion surgery with S2AS addition under fluoroscopy. S2AS loosening and lumbosacral nonunion were analyzed using a 1-year postoperative computed tomography. S2AS insertion accuracy was originally classified as accurate, short, anterior perforation, lateral perforation, and sacroiliac joint (SIJ) deviation among lateral perforation. Clinical data including sex, age, body mass index, fused segments, fusion procedure, primary or revision surgery, Japanese Orthopedic Association scores and complications were collected. Factors associated with S2AS loosening and lumbosacral nonunion were analyzed. RESULTS: A total of 37 patients (74 screws, age: 63.78 ± 13.57 years, female/male: 14/23 patients, body mass index: 23.11 ± 2.53, fused segments: 1-4 levels, revision: 38%) were included. S2AS loosening and lumbosacral nonunion were observed in 18 screws (13%) and 8 patients (22%) respectively. Only 35 screws (47%) were inserted accurately in our classification. Short, lateral perforation, and anterior perforation were observed in 14 screws (19%), 22 screws (30%), and 3 screws (4.1%). SIJ deviation was seen in 15 screws (20%) Factors associated with S2AS loosening were older age (P = 0.038), fusion levels (P = 0.011), and SIJ deviation (P < 0.001). S2AS loosening affects S1 pedicle screw (S1PS) loosening (P = 0.001). Furthermore, S2AS loosening is a risk factor for lumbosacral nonunion (P = 0.046). CONCLUSIONS: S2AS insertion under fluoroscopy is inaccurate. S2AS loosening induces S1PS loosening and lumbosacral nonunion. Surgeons should avoid deviating to SIJ, especially in older patients and relatively longer fusion.


Subject(s)
Pedicle Screws , Spinal Fusion , Humans , Male , Female , Aged , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed , Spinal Fusion/methods , Fluoroscopy
19.
Clin Implant Dent Relat Res ; 26(2): 289-298, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37675656

ABSTRACT

INTRODUCTION: This in vitro study aims to biomechanically evaluate the influence of medium contamination for example, saliva, blood, chlorhexidine (liquid and gel), and fluoride mouthwash on the biomechanical behavior of implant abutments' screws under static and dynamic loading. METHODS: Forty five Ti6Al4V commercial dental implants and abutments were tested in this study. Two main mechanical tests were carried out in the selected media. The first, static, aimed to evaluate the torque loss after the first tightening. The second, dynamic, involved a random cyclic load range between 0 and 200 N to evaluate torque loss due to mastication. In addition, metallographic longitudinal and cross-sections of the abutment-implant apparatus were examined to evaluate the abutment screw-abutment-implant interface. RESULTS: The static torque test showed that irrespective of the media, no statistical difference in static torque loss was found prior to dynamic loading. For the dynamic tests, torque-angle evolution analysis during tightening to 30 Ncm and after the spectrum loading, showed the same global mechanical behavior for all media, but the statistical analysis indicated a difference between the groups in reverse torque values (RTV) and in the torque loss due to dynamic loading. The medium groups CHX, CHX-gel, and Fluoride mouthwash, showed a meaningful torque loss due to loading, but the medium groups, control (no medium), blood and saliva showed an opposite trend and required a higher torque to open the abutment screws. The microstructural analysis revealed clear signs of cold-welding/galling, post-dynamic loading in these latter groups. CONCLUSIONS: The presence of lubrication/contamination media (CHX mouthwash/CHX-gel/Fluoride mouthwash) reduces the preload generated due to tightening but prevents damage due to galling. The observed reduction of RTV clearly emphasizes the need for frequent abutment screw retightening for implant-supported prosthetic long-term stability.


Subject(s)
Dental Implants , Resilience, Psychological , Fluorides , Mouthwashes , Dental Abutments , Dental Stress Analysis , Torque , Dental Implant-Abutment Design
20.
Arch Orthop Trauma Surg ; 144(1): 121-130, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37698623

ABSTRACT

BACKGROUND: Surgical treatment of midshaft clavicle fractures is associated with quick recovery and low risk of non-union. However, fixation failure may occur in case of severe comminution fractures. Moreover, clinical outcomes may be affected when clavicle fractures occur in combination with other injuries, particularly those involving the lower extremities, as the use of crutches or walkers may hinder the process of rehabilitation by adding strain on the acromioclavicular (AC) joint, resulting in possible fixation failure. This study aims to identify risk factors for fixation failure of midshaft clavicle fractures and elucidate the role of combined fractures in treatment outcomes. METHODS: This study included patients diagnosed with midshaft clavicle fractures who underwent initial surgery between January 2012 and November 2021 at a designated regional trauma center hospital. Retrospective evaluation of fixation failure was carried out in 352 patients with midshaft clavicle fractures using standard clinical evaluation protocols and conventional radiographs. The prevalence of fixation failure and the effects of several demographic variables on the risk of fixation failure and non-union were examined. Multivariate logistic regression analysis was carried out to identify independent risk factors for fixation failure. RESULTS: Fixation failure occurred in 40 patients (11.4%). Multivariate analysis identified comminution [odds ratio (OR) 3.532, p value = 0.003, 95% confidence interval (CI) 1.55-8.05)] and fewer number of screws (OR 0.223, p value = 0.022, 95% CI 0.06-0.80) as risk factors for fixation failure. Surgical techniques using wire cerclage reduced the chances of fixation failure in comminuted fractures (OR 0.63, p value = 0.033, 95% CI 0.05-0.80). Combined fractures that required rehabilitation using walkers or crutches increased the risk of non-union (OR 19.043, p value = 0.032, 95% CI 1.28-282.46). CONCLUSIONS: Additional fixation of comminuted fractures using cerclage can reduce the risk of treatment failure, while multiple fractures or rehabilitation for ambulation increases the risk of the same. LEVEL OF EVIDENCE: III.


Subject(s)
Fractures, Bone , Fractures, Comminuted , Fractures, Multiple , Humans , Retrospective Studies , Fractures, Comminuted/surgery , Fractures, Multiple/etiology , Clavicle/surgery , Clavicle/injuries , Fractures, Bone/therapy , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Bone Plates , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...