Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 942
Filter
1.
Article in English | MEDLINE | ID: mdl-38827185

ABSTRACT

Objectives: The efficacy of uncovered self-expandable metal stents (UCSEMS) versus fully covered self-expandable metal stents for distal malignant biliary obstruction remains controversial. Additionally, the heterogeneity of the disease conditions has been indicated in previous studies because pancreatic and non-pancreatic cancers have different characteristics in clinical course. Therefore, the etiology of biliary obstruction necessitates investigations stratified by primary disease. This study aimed to evaluate the outcomes of UCSEMS, specifically for non-pancreatic cancer-induced distal malignant biliary obstruction. Methods: We conducted a single-center retrospective review to evaluate the time to recurrent biliary obstruction and frequency of adverse events (AEs) in patients receiving UCSEMS for unresectable non-pancreatic cancer-induced malignant biliary obstruction. Results: Overall, 32 patients were enrolled in the study between January 2016 and December 2023. The median time to recurrent biliary obstruction was 140 days. AE rates were low at 3.1% for both pancreatitis and cholecystitis, suggesting a potential benefit of UCSEMS in reducing post-procedural AEs. Conclusion: UCSEMS may reduce the risk of post-procedural AEs and should be considered in patients at high risk of post-endoscopic retrograde cholangiopancreatography pancreatitis. However, the patency period may be shorter, necessitating future comparative research with fully covered self-expandable metal stents to determine the optimal stent choice.

2.
Anticancer Res ; 44(8): 3427-3441, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39060047

ABSTRACT

BACKGROUND/AIM: Self-expandable metallic stent (SEMS) placement is becoming the standard bridge-to-surgery (BTS) strategy for potentially curable left-sided obstructive colorectal cancer (OCRC). The study objective was to evaluate the effectiveness of SEMS placement as a BTS strategy for both right- and left-sided OCRC. PATIENTS AND METHODS: We retrospectively compared the short- and long-term outcomes of patients with OCRC who underwent placement of a SEMS versus a trans-nasal/anal decompression tube (DCT). The cohort comprised 57 patients with stage II/III right-sided OCRC (DCT, n=20; SEMS, n=8) or left-sided OCRC (DCT, n=9; SEMS, n=20). The short-term outcomes were the incidence of postoperative complications, rate of laparoscopic surgery, rate of stoma construction, and postoperative hospital stay; long-term outcomes were the 3-year overall survival (OS) and relapse-free survival (RFS). RESULTS: The SEMS group had a higher rate of laparoscopic surgery (85.7% vs. 6.9%, p<0.001), lower rate of stoma construction (10.7% vs. 34.5%, p=0.03), and shorter postoperative hospital stay (14 vs. 17 days, p=0.04) than the DCT group. Both groups had a similar incidence of postoperative complications. The 3-year OS and RFS were also similar in the DCT and SEMS groups for both right-sided OCRC (OS, 75.0% vs. 87.5%, HR=1.51, 95% CI=0.22-10.25, p=0.7; RFS, 65.0% vs. 50.0%, HR=0.97, 95% CI=0.28-3.36, p=0.9) and left-sided OCRC (OS, 88.8% vs. 90.0%, HR=1.19, 95% CI=0.10-14.29, p=0.9; RFS, 77.8% vs. 85.0%, HR=1.03, 95% CI=0.16-6.5, p=0.9). CONCLUSION: SEMS placement is a reasonable BTS strategy for left- and right-sided OCRC that achieves comparable short- and long-term outcomes to DCT insertion.


Subject(s)
Colorectal Neoplasms , Intestinal Obstruction , Self Expandable Metallic Stents , Humans , Male , Female , Colorectal Neoplasms/surgery , Colorectal Neoplasms/complications , Colorectal Neoplasms/pathology , Self Expandable Metallic Stents/adverse effects , Aged , Middle Aged , Intestinal Obstruction/etiology , Intestinal Obstruction/surgery , Retrospective Studies , Treatment Outcome , Postoperative Complications/etiology , Aged, 80 and over , Decompression, Surgical/methods , Laparoscopy
3.
Phys Eng Sci Med ; 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38976186

ABSTRACT

There is little evidence regarding radiation dose perturbation caused by the self-expandable metallic stents (SEMSs) used for transpapillary biliary decompression. We aimed to compare SEMSs with plastic stents (PSs) and clarify their dosimetric characteristics. Fifteen SEMSs (10 braided and 5 lasercut type) and six PSs (diameter: 2.3-3.3 mm) were inserted into a water-equivalent solid phantom. In total, 13 SEMSs had radiopaque markers, whereas the other two did not. Using radiochromic films, the dose difference adjacent to the stents at locations proximal, distal, and arc delivery to the radiation source was evaluated based on comparison to measurement of the dose delivery in phantom without any stent in place. The median values of the dose difference for each stent were used to compare the SEMS and PS groups.Results: The dose difference (median (minimum/maximum)) was as follows: proximal, SEMSs + 2.1% (1.8 / 4.7) / PSs + 5.4% (4.1 / 6.3) (p < 0.001); distal, SEMSs -1.0% (-1.6 /-0.4) / PSs -8.9% (-11.7 / -7.4) (p < 0.001); arc delivery, SEMSs 1.2% (0.9 / 2.3) / PSs 2.2% (1.6 / 3.6) (p = 0.005). These results demonstrated that the dose differences of SEMSs were significantly smaller than those of PSs. On the other hand, the dose difference was large at surface of the radiopaque markers for SEMSs: proximal, 10.3% (7.2 / 20.9); distal, -8.4% (-16.3 / -4.2); arc delivery, 5.5% (4.2 / 9.2). SEMSs for biliary decompression can be safely used in patients undergoing radiotherapy, by focusing on the dose distribution around the stents and by paying attention to local changes in the dose distribution of radiopaque markers.

4.
Ann Gastroenterol ; 37(4): 485-492, 2024.
Article in English | MEDLINE | ID: mdl-38974085

ABSTRACT

Background: Stent selection in the endoscopic management of post-liver-transplant anastomotic biliary strictures remains controversial. This systematic review and meta-analysis aimed to evaluate the potential differences between available stents. Methods: MEDLINE, Cochrane, and Scopus databases were searched until April 2023 for comparative studies evaluating stricture management using multiple plastic stents (MPS) and self-expandable metal stents (SEMS), including fully-covered (FC)- and intraductal (ID)-SEMS. The primary outcome was stricture resolution, while secondary outcomes included stricture recurrence, stent migration and adverse events. Meta-analyses were based on a random-effects model and the results were reported as odds ratios (OR) with 95% confidence intervals (CI). Subgroup analyses by type of metal stent and a cost-effectiveness analysis were also performed. Results: Nine studies (687 patients) were finally included. Considering stricture resolution, SEMS and MPS did not differ significantly (OR 0.99, 95%CI 0.48-2.01; I 2=35%). Stricture recurrence, migration rates and adverse events were also comparable (OR 1.71, 95%CI 0.87-3.38; I 2=55%, OR 0.73, 95%CI 0.32-1.68; I 2=56%, and OR 1.47, 95%CI 0.89-2.43; I 2=24%, respectively). In the subgroup analysis, stricture resolution and recurrence rates did not differ for ID-SEMS vs. MPS or FC-SEMS vs. MPS. Migration rates were lower for ID-SEMS compared to MPS (OR 0.28, 95%CI 0.11-0.70; I 2=0%), and complication rates were higher after FC-SEMS compared to MPS (OR 1.76, 95%CI 1.06-2.93; I 2=0%). Finally, ID-SEMS were the most cost-effective approach, with the lowest incremental cost-effectiveness ratio: 3447.6 £/QALY. Conclusion: Stent type did not affect stricture resolution and recurrence; however, ID-SEMS placement was the most cost-effective approach compared to the alternatives.

5.
J Dig Dis ; 25(5): 310-317, 2024 May.
Article in English | MEDLINE | ID: mdl-38973135

ABSTRACT

OBJECTIVES: Unresectable ampullary cancer (AC) is a rare disease entity. The risk factors for recurrent biliary obstruction (RBO) following endoscopic biliary stenting (EBS) for unresectable AC remain unknown. In this study we aimed to evaluate the cumulative RBO rate and to identify risk factors for RBO following palliative EBS in patients with unresectable AC. METHODS: This multicenter retrospective observational study enrolled consecutive patients with unresectable AC who had undergone palliative EBS between April 2011 and December 2021. The cumulative rate of and risk factors for RBO following palliative EBS were evaluated via multivariate analysis. RESULTS: The study analysis comprised 107 patients with a median age of 84 years (interquartile range 79-88 years). Plastic stents (PSs) and self-expandable metal stents (SEMSs) were placed in 53 and 54 patients, respectively. Functional success was accomplished in 104 (97.2%) patients. Of these, RBO occurred in 62 (59.6%) patients, with obstruction and complete/partial migration occurring in 47 and 15 patients, respectively. The median time to RBO was 190 days. Multivariate analysis showed that PS was associated with a higher rate of RBO compared to SEMS (hazard ratio [HR] 2.48; P < 0.01) and that the presence of common bile duct stones/sludge immediately after EBS was an independent risk factor for RBO (HR 1.99; P = 0.04). CONCLUSIONS: The use of SEMS compared to PS during EBS reduced the time to RBO in patients with unresectable AC. Common bile duct stones/sludge immediately after EBS was a risk factor for RBO.


Subject(s)
Ampulla of Vater , Cholestasis , Common Bile Duct Neoplasms , Palliative Care , Recurrence , Stents , Humans , Male , Female , Aged, 80 and over , Retrospective Studies , Aged , Ampulla of Vater/surgery , Risk Factors , Cholestasis/etiology , Cholestasis/surgery , Stents/adverse effects , Common Bile Duct Neoplasms/surgery , Common Bile Duct Neoplasms/complications , Palliative Care/methods , Self Expandable Metallic Stents/adverse effects , Cholangiopancreatography, Endoscopic Retrograde/adverse effects
6.
Ann Coloproctol ; 40(3): 268-275, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38946096

ABSTRACT

PURPOSE: Stenting is a useful treatment option for malignant colonic obstruction, but its role remains unclear. This study was designed to establish how stents have been used in Queensland, Australia, and to review outcomes. METHODS: Patients diagnosed with colorectal cancer in Queensland from January 1, 2008, to December 31, 2014, who underwent colonic stent insertion were reviewed. Primary outcomes of 5-year survival, 30-day mortality, and overall length of survival were calculated. The secondary outcomes included patient and tumor factors, and stoma rates. RESULTS: In total, 319 patients were included, and distant metastases were identified in 183 patients (57.4%). The 30-day mortality rate was 6.6% (n=21), and the 5-year survival was 11.9% (n=38). Median survival was 11 months (interquartile range, 4-27 months). A further operation (hazard ratio [HR], 0.19; P<0.001) and chemotherapy and/or radiotherapy (HR, 0.718; P=0.046) reduced the risk of 5-year mortality. The presence of distant metastases (HR, 2.052; P<0.001) and a comorbidity score of 3 or more (HR, 1.572; P=0.20) increased mortality. Surgery was associated with a reduced risk of mortality even in patients with metastatic disease (HR, 0.14; P<0.001). Twenty-two patients (6.9%) ended the study period with a stoma. CONCLUSION: Colorectal stenting was used in Queensland in several diverse scenarios, in both localized and metastatic disease. Surgery had a survival advantage, even in patients with metastatic disease. There was no survival difference according to whether patients were socioeconomically disadvantaged, diagnosed in a major city or not, or treated at private or public hospitals. Stenting proved a valid treatment option with low stoma rates.

7.
J Clin Med ; 13(13)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38999371

ABSTRACT

Esophagectomy, while a pivotal treatment for esophageal cancer, is not without adverse events. Among these, anastomotic leak (AL) is the most feared complication, threatening patient lives and incurring significant healthcare costs. The management of AL is complex and lacks standardization. Given the high morbidity and mortality rates associated with redo-surgery, which poses risks for already fragile patients, various endoscopic treatments have been developed over time. Self-expandable metallic stents (SEMSs) were the most widely used treatment until the early 2000s. The mechanism of action of SEMSs includes covering the wall defect, protecting it from secretions, and promoting healing. In 2010, endoscopic vacuum therapy (EVT) emerged as a viable alternative for treating ALs, quickly gaining acceptance in clinical practice. EVT involves placing a dedicated sponge under negative pressure inside or adjacent to the wall defect, aiming to clear the leak and promote granulation tissue formation. More recently, the VAC-Stent entered the scenario of endoscopic treatment of post-esophagectomy ALs. This device combines a fully covered SEMS with an integrated EVT sponge, blending the ability of SEMSs to exclude defects and maintain the patency of the esophageal lumen with the capacity of EVT to aspirate secretions and promote the formation of granulation tissue. Although the literature on this new device is not extensive, early results from the application of VAC-Stent have shown promising outcomes. This review aims to synthesize the preliminary efficacy and safety data on the device, thoroughly analyze its advantages over traditional techniques and disadvantages, explore areas for improvement, and propose future directions.

8.
Clin Endosc ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38978397

ABSTRACT

Endoscopic ultrasound (EUS)-guided interventions have evolved rapidly in recent years, with dedicated metal stents playing a crucial role in this process. Specifically, the invention of biflanged short metal-covered stents, including lumen-apposing metal stents (LAMS), and modifications in a variety of tubular self-expandable metal stents (SEMS), have led to innovations in EUS-guided interventions. LAMS or non-LAMS stents are commonly used in the EUS-guided drainage of pancreatic fluid collections, especially in cases of walled-off necrosis. Additionally, LAMS is commonly considered for drainage of the EUS-guided gallbladder or dilated common bile duct and EUS-guided gastroenterostomy. Fully or partially covered tubular SEMS with several new designs are being considered for EUS-guided biliary drainage. This review focuses on advances in SEMS for EUS-guided interventions and discusses related research results.

9.
Article in English | MEDLINE | ID: mdl-39044062

ABSTRACT

PURPOSE: During endoscopic ear surgery (EES), it is important to maintain a clear view of the endoscopic camera to achieve a clean field. In this study, a self-expandable external auditory canal (EAC) retainer was developed to enable a more efficient and safer EES. This study aimed to evaluate the retainer's efficacy and safety in EES. METHODS: Among adult patients scheduled for endoscopic tympanoplasty, 50 participants were recruited. They were assigned to either the retainer or control group in a 1:1 ratio. The anatomical characteristics, number of endoscopic cleanings during surgery, surgeon's satisfaction, and other factors were evaluated. RESULTS: No differences were observed in the surgical direction, EAC size measured on preoperative temporal bone computed tomography scans, location and size of tympanic membrane perforation, or bleeding degree between the two groups. When comparing the surgical time, including retainer insertion and removal, the time was similar between groups (retainer group, 35 min; control group, 33.2 min). The frequency of endoscopic cleaning per minute was statistically significantly lower in the retainer group than in the control group (0.18 times per minute, p = 0.048). No side effects, including sensory abnormalities or allergic reactions, were reported in any patient who used the retainer. CONCLUSION: A reduction in unnecessary endoscopic cleaning during EES was observed while using the self-expandable retainer, leading to increased surgeon satisfaction and efficiency. Furthermore, as a safe method without side effects, the retainer could be widely used to various indications for EES beyond tympanoplasty.

10.
World J Transplant ; 14(2): 91081, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38947975

ABSTRACT

BACKGROUND: Endoscopic management is the first-line therapy for post-liver-transplant anastomotic strictures. Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months, data on safety and duration for metal stents in this setting is scarce. Due to limited access to endoscopic retrograde cholangiopancreatography (ERCP) during the coronavirus disease 2019 pandemic in our centre, there was a change in practice towards increased usage and length-of-stay of the Kaffes biliary intraductal self-expanding stent in patients with suitable anatomy. This was mainly due to the theoretical benefit of Kaffes stents allowing for longer indwelling periods compared to the traditional plastic stents. AIM: To compare the safety and efficacy profile of different stenting durations using Kaffes stents. METHODS: Adult liver transplant recipients aged 18 years and above who underwent ERCP were retrospectively identified during a 10-year period through a database query. Unplanned admissions post-Kaffes stent insertion were identified manually through electronic and scanned medical records. The main outcome was the incidence of complications when stents were left indwelling for 3 months vs 6 months. Stent efficacy was calculated via rates of stricture recurrence between patients that had stenting courses for ≤ 120 d or > 120 d. RESULTS: During the study period, a total of 66 ERCPs with Kaffes insertion were performed in 54 patients throughout their stenting course. In 33 ERCPs, the stent was removed or exchanged on a 3-month interval. No pancreatitis, perforations or deaths occurred. Minor post-ERCP complications were similar between the 3-month (abdominal pain and intraductal migration) and 6-month (abdominal pain, septic shower and embedded stent) groups - 6.1% vs 9.1% respectively, P = 0.40. All strictures resolved at the end of the stenting course, but the stenting course was variable from 3 to 22 months. The recurrence rate for stenting courses lasting for up to 120 d was 71.4% and 21.4% for stenting courses of 121 d or over (P = 0.03). There were 28 patients that were treated with a single ERCP with Kaffes, 21 with removal after 120 d and 7 within 120 d. There was a significant improvement in stricture recurrence when the Kaffes was removed after 120 d when a single ERCP was used for the entire stenting course (71.0% vs 10.0%, P = 0.01). CONCLUSION: Utilising a single Kaffes intraductal fully-covered metal stent for at least 4 months is safe and efficacious for the management of post-transplant anastomotic strictures.

11.
Clin Endosc ; 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38872407

ABSTRACT

Background/Aims: Advanced pancreatic and biliary tract cancers can invade the duodenum and cause duodenal hemorrhagic stenosis. This study aimed to evaluate the efficacy of covered self-expandable metal stents in the treatment of cancer-related duodenal hemorrhage with stenosis. Methods: Between January 2014 and December 2016, metal stents were placed in 51 patients with duodenal stenosis. Among these patients, a self-expandable covered metal stent was endoscopically placed in 10 patients with hemorrhagic duodenal stenosis caused by pancreatobiliary cancer progression. We retrospectively analyzed the therapeutic efficacy of the stents by evaluating the technical and clinical success rates based on successful stent placement, degree of oral intake, hemostasis, stent patency, and overall survival. Results: The technical and clinical success rates were 100%. All 10 patients achieved a Gastric Outlet Obstruction Scoring System score of three within two weeks after the procedure and had no recurrence of melena. The median stent patency duration and overall survival after stent placement were 52 days (range, 20-220 days) and 66.5 days (range, 31-220 days), respectively. Conclusions: Endoscopic placement of a covered metal stent for hemorrhagic duodenal stenosis associated with pancreatic or biliary tract cancer resulted in duodenal hemostasis, recanalization, and improved quality of life.

12.
Article in English | MEDLINE | ID: mdl-38845460

ABSTRACT

BACKGROUND AND AIM: Endoscopic ultrasound-guided gastroenterostomy is a procedure used to connect the stomach and dilated afferent loop using a stent under endoscopic ultrasound for afferent loop syndrome. However, the actual efficacy and safety of this procedure remain unclear. Therefore, this retrospective study aimed to evaluate the efficacy and safety of endoscopic ultrasound-guided gastroenterostomy using a laser-cut-type fully covered self-expandable metallic stent and an anchoring plastic stent for afferent loop syndrome. METHODS: Technical and clinical success rates, adverse events, recurrent intestinal obstruction rates, time to recurrent intestinal obstruction, and technical and clinical success rates of re-intervention were evaluated in intended patients who underwent endoscopic ultrasound-guided gastroenterostomy for afferent loop syndrome from October 2018 to August 2022. RESULTS: In 25 intended patients with afferent loop syndrome who intended endoscopic ultrasound-guided gastroenterostomy, the technical success rate was 100% (25/25), whereas the clinical success rate was 96% (24/25). Two patients experienced grade ≥ 3 early adverse events, including one with intra-abdominal abscess and one with hypotension. Both events were attributed to intestinal fluid leakage. No late adverse events were observed. The recurrent intestinal obstruction rate was 32% (8/25), and the median time to recurrent intestinal obstruction was 6.5 months (95% confidence interval: 2.8-not available). The technical and clinical success rates of re-intervention were both 100% (8/8). CONCLUSIONS: Endoscopic ultrasound-guided gastroenterostomy using a fully covered self-expandable metallic stent and an anchoring plastic stent is effective and safe as a treatment procedure for afferent loop syndrome.

13.
Clin J Gastroenterol ; 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38849634

ABSTRACT

We report a case of an 87 year-old woman who was admitted with jaundice, but had no pain or fever. Contrast-enhanced computed tomography revealed a tumor in the head of the pancreas, which caused distal malignant biliary obstruction. Initial transpupillary drainage by endoscopic retrograde cholangiopancreatography (ERCP) was difficult due to severe biliary stricture caused by the tumor, but cannulation of the pancreatic duct was successful. Pancreatic ductal adenocarcinoma was revealed through cytologic examination of pancreatic juice and the patient underwent percutaneous transhepatic biliary drainage (PTBD). 16 days after the jaundice was resolved, an uncovered Zilver® metallic stent was successfully deployed using a guidewire from the PTBD route, and the patient was discharged with palliative care due to advanced age. However, 54 days after discharge, the patient presented with black vomiting and recurrent jaundice. ERCP revealed an obstructed stent with black debris, and further evaluation revealed a ruptured pseudoaneurysm that branched off the gastroduodenal artery within the metallic biliary stent. Angiography revealed that embolization was successful. The patient recovered and was discharged without further episodes.

14.
J Clin Med ; 13(12)2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38929948

ABSTRACT

Background: Esophageal self-expandable metal stents (SEMS) are an important endoscopic tool. These stents have now been adapted successfully to manage post-bariatric surgery complications such as anastomotic leaks and strictures. In centers of expertise, this has become the primary standard-of-care treatment given its minimally invasive nature, and that it results in early oral feeding, decreased hospitalization, and overall favorable outcomes. Self-expandable metal stents (SEMS) fractures are a rare complication of unknown etiology. We aimed to investigate possible causes of SEMS fractures and highlight a unique endoscopic approach utilized to manage a fractured and impaled SEMS. Methods: This is a retrospective study of consecutive patients who underwent esophageal SEMS placement between 2015-2021 at a tertiary referral center to identify fractured SEMS. Patient demographics, stent characteristics, and possible etiologies of fractured SEMS were identified. A comprehensive literature review was also conducted to evaluate all prior cases of fractured SEMS and to hypothesize fracture theories. Results: There were seven fractured esophageal SEMS, of which six were used to manage post-bariatric surgery complications. Five SEMS were deployed with their distal ends in the gastric antrum and proximal ends in the distal esophagus. All stents fractured within 9 weeks of deployment. Most stents (5/7) were at least 10 cm in length with fractures commonly occurring in the distal third of the stents (6/7). The wires of a fractured SEMS were embedded within the esophagogastric junction in one case, prompting the use of an overtube that was synchronously advanced while steadily extracting the stent. Discussion: We suggest the following four etiologies of SEMS fractures: anatomical, physiological, mechanical, and chemical. Stent curvature at the stomach incisura can lead to strain- and stress-related fatigue due to mechanical bending with exacerbation from respiratory movements. Physiologic factors (gastric body contractions) can result in repetitive squeezing of the stent, adding to metal fatigue. Intrinsic properties (long length and low axial force) may be contributing factors. Lastly, the stomach acidic environment may cause nitinol-induced chemical weakness. Despite the aforementioned theories, SEMS fracture etiology remains unclear. Until more data become available, it may be advisable to remove these stents within 6 weeks.

15.
Gastroenterol Hepatol ; : 502218, 2024 Jun 08.
Article in English, Spanish | MEDLINE | ID: mdl-38857753

ABSTRACT

INTRODUCTION: Self-expandable metallic stents (SEMS) have been widely placed for unresectable distal malignant biliary obstruction (UDMBO). However, the dysfunction rate is 19-40% and its treatment is controversial. We aimed asses the efficacy and safety of a secondary biliary stents (uncovered (UC) versus fully-covered (FC) stent) for the management of occluded SEMS. PATIENTS AND METHODS: Between 2015 and June 2023, 41 patients with UDMBO underwent secondary biliary stent placement as "stent-in-stent" (20 FCSEMS and 21 UCSEMS). The primary outcomes were technical and clinical success of SEMS placement. Secondary outcomes included adverse events (AEs), patency and survival. Patients were prospectively followed until death or loss of follow-up. RESULTS: Technical (100% vs 85.5%) and clinical (100% vs 95.2%) success rates were similar in FCSEMS and UCSEMS groups. The median follow-up period was 510 days (range 290-630). The median duration of stent patency of FCSEMS (220 days, IQR 137.5-442.5) was longer than UCSEMS (150 days, IQR 110-362.5) (P=0.395), although stent dysfunction within 6 months was not different between groups. Multivariate analysis indicated that sex (HR=0.909, 0.852-0.970), antitumor treatment (HR=0.248, 0.032-0.441), stent patency (HR=0.992, 0.986-0.998) and clinical success (HR=0.133, 0.026-0.690) were significant factors for overall survival. There were no remarkable differences in AEs. CONCLUSIONS: The placement of additional biliary stent using the stent-in-stent method is an effective and safe rescue treatment for patients with UDMBO and occluded stent. In addition, the use of FCSEMS compared UCSEMS has unclear benefits regarding stent patency and overall survival.

17.
Gastrointest Endosc ; 2024 May 08.
Article in English | MEDLINE | ID: mdl-38729316

ABSTRACT

[BACKGROUND AND AIMS]: Endoscopic interventions for bile duct stones (BDS) with benign choledochojejunal anastomotic stenosis (bCJS) are challenging. Therefore, we investigated endoscopic interventions for BDS with bCJS. [METHODS]: Seventeen patients with BDS with bCJS were retrospectively analyzed. Patient characteristics, technical success, adverse events (AEs), and recurrence were evaluated. [RESULTS]: In 17 patients, the median diameters of the bile duct and BDS were both 8 mm. The median number of BDS was 3. The technical success rate was 94% (16/17). Ten patients underwent balloon dilation at the choledochojejunal anastomotic site (CAS), the median diameter of balloon dilation was 10.5 mm, and waist disappearance was achieved in 2. Six patients had fully covered self-expandable metal stents (FCSEMS) with a diameter of 10 mm placed at the CAS. BDS were removed after balloon dilation or FCSEMS removal, and 6 out of 16 patients were treated with a combination of lithotripsy and 5 with peroral direct cholangioscopy (PDCS). Regarding AEs, perforation at the CAS by balloon dilation occurred in 1 patient. The median follow-up was 3701 days. Nine out of 16 patients (56%) had recurrence. The patients treated with combination of PDCS at BDS removal (p=0.022) and waist disappearance at the CAS by balloon dilation (p=0.035) had significantly fewer recurrences. [CONCLUSIONS]: Endoscopic interventions for BDS with bCJS are useful and relatively safe; however, long-term follow-ups showed frequent recurrences. Recurrence was common in patients not treated with the combination of PDCS at BDS removal and those without waist disappearance at the CAS by balloon dilation.

18.
Asian Cardiovasc Thorac Ann ; 32(4): 227-230, 2024 May.
Article in English | MEDLINE | ID: mdl-38751049

ABSTRACT

PURPOSE: To describe our clinical experience of endovascular exclusion of popliteal artery aneurysms using the new self-expandable covered stent SOLARIS® (Scitech Medical, Brazil), and to report its results in the context of surgical and endovascular treatment of popliteal artery aneurysms. CASE REPORT: Among 20 popliteal artery aneurysms undergoing open or endovascular repair in 2022 and 2023, two patients were successfully treated with the Solaris stentgraft. Both patients had a patent popliteal artery and three run-off vessels. After stentgraft implantation, they received dual antiplatelet therapy for three months and they were followed-up with Duplex scan and clinical evaluation after three months, and every six months thereafter. After three months, one Solaris stentgraft had complete thrombosis and the other ruptured, requiring surgical removal. No complications were observed among the other aneurysms treated with open repair or with the Viabahn® stentgraft. CONCLUSIONS: Endovascular treatment of popliteal aneurysms with the new covered self-expandable stent Solaris resulted in severe complications in the two cases reported, and in worse short-term outcomes than endovascular repair with Viabahn® and open repair. Its off-label use to treat popliteal artery aneurysms should be therefore discouraged.


Subject(s)
Aneurysm , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Popliteal Artery , Prosthesis Design , Stents , Humans , Popliteal Artery/diagnostic imaging , Popliteal Artery/surgery , Popliteal Artery/physiopathology , Aneurysm/surgery , Aneurysm/diagnostic imaging , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Male , Aged , Vascular Patency , Platelet Aggregation Inhibitors/therapeutic use , Female , Time Factors , Middle Aged , Dual Anti-Platelet Therapy , Computed Tomography Angiography , Popliteal Artery Aneurysm
SELECTION OF CITATIONS
SEARCH DETAIL
...