Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Mikrochim Acta ; 190(8): 321, 2023 07 25.
Article in English | MEDLINE | ID: mdl-37491620

ABSTRACT

Neglected tropical diseases are those caused by infectious agents or parasites and are considered endemic in low-income populations. These diseases also have unacceptable indicators and low investment in research, drug production, and control. Tropical diseases such as leishmaniasis are some of the main causes of morbidity and mortality around the globe. Electrochemical immunosensors are promising tools for diagnostics against these diseases. One such benefit is the possibility of assisting diagnosis in isolated regions, where laboratory infrastructure is lacking. In this work, different peptides were investigated to detect antibodies against Leishmania in human and canine serum samples. The peptides evaluated (395-KKG and 395-G) have the same recognition site but differ on their solid-binding domains, which ensure affinity to spontaneously bind to either graphene oxide (GO) or graphene quantum dots (GQD). Cyclic voltammetry and differential pulse voltammetry were employed to investigate the electrochemical behavior of each assembly step and the role of each solid-binding domain coupled to its anchoring material. The graphene affinity peptide (395-G) showed better reproducibility and selectivity when coupled to GQD. Under the optimized set of experimental conditions, negative and positive human serum samples responses were distinguished based on a cut-off value of 82.5% at a 95% confidence level. The immunosensor showed selective behavior to antibodies against Mycobacterium leprae and Mycobacterium tuberculosis, which are similar antibodies and potentially sources of false positive tests. Therefore, the use of the graphene affinity peptide as a recognition site achieved outstanding performance for the detection of Leishmania antibodies.


Subject(s)
Biosensing Techniques , Graphite , Leishmaniasis , Animals , Dogs , Humans , Carbon/chemistry , Graphite/chemistry , Reproducibility of Results , Immunoassay , Peptides , Antibodies , Leishmaniasis/diagnosis
2.
Biosensors (Basel) ; 12(10)2022 Oct 17.
Article in English | MEDLINE | ID: mdl-36291021

ABSTRACT

The development of immunosensors to detect antibodies or antigens has stood out in the face of traditional methods for diagnosing emerging diseases such as the one caused by the SARS-CoV-2 virus. The present study reports the construction of a simplified electrochemical immunosensor using a graphene-binding peptide applied as a recognition site to detect SARS-CoV-2 antibodies. A screen-printed electrode was used for sensor preparation by adding a solution of peptide and reduced graphene oxide (rGO). The peptide-rGO suspension was characterized by scanning electron microscopy (SEM), Raman spectroscopy, and Fourier transform infrared spectroscopy (FT-IR). The electrochemical characterization (electrochemical impedance spectroscopy-EIS, cyclic voltammetry-CV and differential pulse voltammetry-DPV) was performed on the modified electrode. The immunosensor response is based on the decrease in the faradaic signal of an electrochemical probe resulting from immunocomplex formation. Using the best set of experimental conditions, the analytic curve obtained showed a good linear regression (r2 = 0.913) and a limit of detection (LOD) of 0.77 µg mL-1 for antibody detection. The CV and EIS results proved the efficiency of device assembly. The high selectivity of the platform, which can be attributed to the peptide, was demonstrated by the decrease in the current percentage for samples with antibody against the SARS-CoV-2 S protein and the increase in the other antibodies tested. Additionally, the DPV measurements showed a clearly distinguishable response in assays against human serum samples, with sera with a response above 95% being considered negative, whereas responses below this value were considered positive. The diagnostic platform developed with specific peptides is promising and has the potential for application in the diagnosis of other infections that lead to high antibody titers.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , Humans , Graphite/chemistry , Biosensing Techniques/methods , Electrochemical Techniques/methods , SARS-CoV-2 , Spectroscopy, Fourier Transform Infrared , Immunoassay , COVID-19/diagnosis , Electrodes , Limit of Detection , Peptides