ABSTRACT
ABSTRACT Purpose: This quality and reliability study aimed to identify the mass variability of multidose eyedrops and to verify the existence of a reference pattern for the drop volume of eyedrops using standard lubricant eyedrops available on the Brazilian market. Methods: Five brands of lubricant eyedrops were evaluated. An ideal standard 20 µL drop of eyedrops from each manufacturer was captured using an adjustable micropipette. The eyedrop bottles were randomly selected, and five measurements of the samples' masses were collected using calibrated precision scales. Results: The mass of the 20 µL samples varied significantly (p<0.001) among the different manufacturers. However, among eyedrops of the same brand, mass variation was not statistically different. The global mean mass of all weighed drops was 18.24 mg, and non-uniformity was identified across all eyedrop brands. Conclusion: Significant variations in the drop masses of common lubricant eyedrops were identified using standard laboratory equipment. Heterogeneity in the drop volume of standard eyedrop medications suggest that potential dosage discrepancies exist, possibly altering treatment efficacy. A pre-established reference measure may lead to the production of more appropriately sized eyedrops for use in human eyes.
RESUMO Objetivo: Este estudo de qualidade e confiabilidade teve como objetivo identificar a variabilidade da massa do volume da gota de colírios multidose e verificar a existência de um padrão de referência para o volume da gota dos colírios usando lágrimas artificiais do mercado brasileiro. Métodos: Cinco marcas de colírios lubrificantes foram avaliadas quanto ao volume da gota. Uma gota padrão ideal de 20 µL de cada fabricante foi coletada usando uma micropipeta ajustável. Os frascos dos colírios foram selecionados aleatoriamente e cinco medidas das massas das amostras foram coletadas usando escalas de precisão calibradas. Resultados: A massa das amostras de 20 µL variou significativamente (p<0,001) entre os diferentes fabricantes. No entanto, entre os colírios da mesma marca, a variação da massa não foi estatisticamente diferente. A massa média global de todas as gotas pesadas foi de 18,24 mg e foi observada uma não-uniformidade entre todas as marcas de colírios. Conclusão: Identificou-se uma variação significativa nas massas do volume das gotas dos colírios lubrificantes, usando equipamento padrão de laboratório. A heterogeneidade no volume da gota dos colírios testados sugere a existência de discrepâncias potenciais em suas posologias, possivelmente alterando a eficácia do tratamento. Uma medida de referência pré-estabelecida pode levar à produção de colírios com gotas de tamanho mais apropriado para uso em olhos humanos.
ABSTRACT
RESUMO Objetivo: Comparar a eficácia fenilefrina a 10% aplicada pelo próprio paciente por vaporização em olho fechado em relação à instilação de gota em olho aberto em indivíduos que irão realizar exame de fundoscopia e avaliar o nível de dificuldade e a adequação técnica entre os métodos de administração. Métodos: Ensaio clínico controlado, randomizado e pareado realizado em 2014 envolvendo 100 olhos de 50 pacientes na Policlínica Ronaldo Gazolla - RJ, sem doenças oculares ou sistêmicas que comprometiam a dilatação pupilar. Os pacientes foram submetidos à instilação de 1 gota de fenilefrina a 10% e aplicação de vaporizador do mesmo midriático no olho contralateral. O olho em que se instilou o colírio permaneceu aberto, enquanto o olho vaporizado ficou fechado durante as aplicações da medicação. O diâmetro pupilar foi medido antes da aplicação, 10, 20 e 30 minutos após. O processo de instilação ou vaporização foi observado quanto a sua adequação técnica por um dos autores. Após o processo foi perguntado ao paciente questões pré-formuladas sobre a praticidade de ambos os métodos. Resultados: A diferença de midríase média entre os grupos de olhos avaliados em um determinado tempo foi no máximo 0,3 mm , o que não foi clinicamente ou estatisticamente significativo (ANOVA: F = 1,97 e p = 0,163609) . Porém, ao longo do tempo, a diferença entre o diâmetro da pupila no tempo inicial e no tempo de 30 minutos foi 1,15 mm para os olhos vaporizados e 1,58 mm para os olhos instilados com gotas (ANOVA: F = 129,22 e p ≤ 0,0001). Percentual de 60% dos pacientes tocaram a ponta do frasco de colírio nos olhos, enquanto que 12% tocaram o orifício na ponta do vaporizador com os dedos (p < 0,000001). Setenta de dois por cento (72%) consideraram a instilação de gotas fácil ou muito fácil enquanto 62% consideraram a vaporização em olho fechado fácil ou muito fácil (p = 0,238). Conclusão: A instilação de gotas em olhos abertos e a vaporização de olhos fechados da fenilefrina a 10% apresentou eficácia clínica semelhante. A vaporização foi mais segura e apresentou nível de dificuldade um pouco maior do que a instilação, apesar dos pacientes serem experientes para instilar gotas e inexperientes para vaporizar a medicação em olho fechado.
ABSTRACT Objective: To compare the effectiveness of phenylephrine 10% applied by a spray onto the eye closed over drop instillation onto an open eye on patients who will perform ophthalmoscopy and assess the level of difficulty and technical adequacy of the administration methods. Methods: The study was a clinical trial, controlled, randomized and paired, performed in 2014, involving 100 eyes of 50 patients in the Polyclinic Ronaldo Gazolla - RJ, with no ocular or systemic diseases that compromised the pupillary dilation. Patients underwent 10% phenylephrine eye drop instillation onto one open eye and spray application onto the other eye, which was closed. Pupillary diameter was measured before application and 10, 20, 30 minutes after. The process of instillation or vaporization was observed for its technical correctness by one of the authors. A questionnaire was asked to the patient about the difficulty of both methods after topical administration. Results: The average mydriasis difference between the eye groups assessed at a given time was at most 0.3 mm, which was not clinically or statistically significant (ANOVA: F = 1.97 and p = 0.163609). However, over time, the difference between the average pupil diameter before application and after 30 minutes was 1.15 mm to vaporized eyes and to 1.58 mm in eyes instilled with drops (ANOVA: F = 129, 22 and p ≤ 0.0001). Sixty per cent of patients touched the tip of the eye drop bottle onto the eye, while 12% touched the tip of the vaporizer with their fingers (p <0.000001). Seventy two percent (72%) considered the drops instillation easy or very easy, while 62% considered vaporization in a closed eye easy or very easy (p = 0.238). Conclusion: The instillation of drops phenylephrine 10% in open eyes and the vaporization onto closed eyes showed similar clinical efficacy. Vaporization was safer and a little more difficult than instillation, despite the patients being experienced for instilling drops and inexperienced to vaporize the medication in a closed eye.
Subject(s)
Humans , Male , Female , Middle Aged , Administration, Topical , Eye/drug effects , Mydriatics/administration & dosage , Ophthalmic Solutions/administration & dosage , Phenylephrine , Instillation, Drug , Randomized Controlled Trial , Surveys and QuestionnairesABSTRACT
RESUMO Objetivo: Avaliar a variação intra e interexaminadores do volume de gotas dispensados de frascos de colírios lubrificantes disponíveis no mercado. Métodos: Foram estudados cinco frascos de colírios lubrificantes e dezenove voluntários participaram deste estudo. A massa média de gotas de 20µl dos colírios foi obtida utilizando micropipeta e balança de precisão e como padrão para comparação com a massa das gotas obtidas pelos voluntários. Cinco gotas de cada frasco foram pesadas individualmente com o tubo de colírio perpendicular à balança, usando o primeiro e segundo dedos da mão direita, de forma que a pressão fosse aplicada somente no meio do frasco. Os experimentos foram realizados em uma sala climatizada a temperatura ambiente (21±1°C). Resultados: Todos os frascos de colírios apresentaram variação estatisticamente significante das massas das gotas obtidas pelos examinadores quando comparadas com a massa média padrão de 0,0182±0,0014g, com exceção da comparação entre os dados do colírio A com o colírio D, que não apresentou variação estatisticamente significante. Conclusão: O presente estudo demonstra a ausência de uniformidade das gotas dispensadas pelos frascos de colírios disponíveis no mercado e a sua inadequação à real necessidade, uma vez que as gotas dispensadas são maiores do que o indicado. Esse fato torna-se um problema quando se trata de período de tratamento prolongado, especialmente com colírios dispendiosos como os indicados para a terapêutica do glaucoma. Nesse sentido, a padronização das gotas de colírios se faz necessária.
ABSTRACT Objective: To evaluate the intra and inter variations of eye drops volume dispensed from bottles available on the market. Methods: Five bottles of lubricant eye drops were studied and nineteen volunteers participated in this study. The average mass from 20µl of eye drops was obtained using accuracy micropipette and balance, and used as standard for comparison with the mass of the drops obtained by the volunteers. Five drops of each vial were individually weighed with the tube perpendicular to the balance, using the first and second fingers of the right hand, so that the pressure was applied only in the middle of the flask. The experiments were performed in a room temperature (21±1°C). Results: All eye drops bottles showed a statistically significant variation on masses of the drops obtained by examiners when compared with the standard average weight of 0.0182±0,0014g, except when compared A with D eye drops, with no statistically significant variation. Conclusion: This study demonstrates the lack of uniformity of drops dispensed by eye drops bottles available in the market and its inadequacy to the real need, since the dispensed drops are larger than indicated.This fact becomes a problem when it comes to long treatment period, especially with expensive drops as indicated for glaucoma therapy. In this sense, the standardization of drops of eye drops is necessary.
Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Drug Packaging/standards , Lubricant Eye Drops/administration & dosage , Lubricant Eye Drops/standards , Instillation, Drug , Drug Administration Schedule , Drug Costs , Equipment Design , Lubricant Eye Drops/economicsABSTRACT
RESUMO Objetivo: Determinar o grau de dificuldade para instilação tópica ocular em idosos, com ou sem o auxílio de dispositivo de apoio facial, por meio de questionário. Observar qual método foi tecnicamente melhor para aplicação tópica ocular de gotas. Métodos: O estudo foi um ensaio clínico, controlado, randomizado e pareado, realizado em 50 pacientes idosos de setembro de 2015 a junho de 2016 na Policlínica Ronaldo Gazolla, Lapa-Rio de Janeiro. Um frasco de colírio Optive® foi acoplado ao dispositivo de apoio facial denominado Eyedrop®. Cada participante instilou o colírio com ou sem o auxílio do dispositivo em cada um dos olhos, sendo que a seleção ocular foi feita aleatoriamente. Foi perguntado ao paciente questões pré-formuladas sobre a dificuldade de ambos os métodos e a técnica de administração tópica ocular foi avaliada. Resultados: A instilação de gotas foi considerada difícil ou muito difícil por 10% dos idosos com o auxílio do dispositivo e por 36% sem o auxílio (p = 0,0047). Houve toque da ponta do colírio com os tecidos oculares em 64% dos pacientes que não usaram o Eyedrop® e em 4% dos que o utilizaram (p=0,000001). A maior dificuldade descrita na instilação tradicional foi acertar o olho com a gota (32%) e com o dispositivo de apoio foi entender seu uso(4%). Conclusão: A maioria dos idosos instila colírios erroneamente, tocando a ponta do frasco em tecidos oculares, o que favorece sua contaminação. O dispositivo de apoio facial tornou mais segura e fácil a instilação.
ABSTRACT Objective: To determine the degree of difficulty for topical ocular instillation in the elderly, through a questionnaire, with or without the aid of facial support device. Observe which method was technically better to topical ocular application of drops. Methods: The study was a clinical trial, controlled, randomized and paired, which was conducted in 50 elderly patients from September 2015 to June 2016 at the Polyclinic Ronaldo Gazolla, Lapa, Rio de Janeiro. A Optive® eyedrop bottle was attached to a facial support device called Eyedrop®. Each participant instilled an eye drop with or without the device help in each of both eyes, wherein the eye selection was made randomly. He was asked to answer pre-formulated questions about the difficulty of both methods and the topical ocular administration technique was evaluated. Results: Eye drop instillation was difficult or very difficult for 10% of the elderly with the device aid and for 36% without it (p = 0.0047). There were bottle tip touch onto the ocular tissues in 64% of patients who did not use Eyedrop® and 4% who used it (p = 0.000001). The greatest difficulty described in traditional instillation was to head properly the eye drop (32%) and when the support device was used, it was to understand how to use it (4%). Conclusion: Most elderly instills eye drops mistakenly, touching the tip of the bottle onto ocular tissues, which favors contamination. The facial support device increased security and facility in instillation.
Subject(s)
Humans , Male , Female , Aged , Administration, Topical , Equipment and Supplies , Eye/drug effects , Lubricant Eye Drops , Ophthalmic Solutions/administration & dosage , Perception , Randomized Controlled Trial , Surveys and QuestionnairesABSTRACT
RESUMO Objetivo: Determinar o volume médio das gotas produzidas pelos colírios lubrificantes em diferentes ângulos de inclinação e determinar o custo médio do tratamento. Métodos: Determinação do volume da gota de 3 frascos originais dos colírios lubrificantes Artelac®, Hylo Comod®, Lacrima® Plus, Systane® UL, Lacrifilm®, Hyabak®, Lacribell®, Ecofilm®, Mirugell®, Plenigell®, Fresh Tears®, Optive® e Endura® à inclinação de 90º e 45º. Determinou-se o número médio de gotas em cada frasco e foi feita avaliação farmacoeconômica dos colírios. Resultados: O volume das gotas variou de 32,2 a 64,0 µL a 45o e de 29,1 a 65,1 µL a 90o. A diferença entre as gotas em cada inclinação foi de 2 a 24% e o custo anual dos colírios de acordo com a inclinação variou de R$2,73 a R$130,73. A Duração Máxima de Tratamento (DMT) foi de 29,3 a 51,4 dias na inclinação de 45o, e de 28,8 a 48,4 dias a 90º, sendo que a diferença na DMT foi de 0,5 até 8 dias a mais ou a menos, de acordo com a marca. Conclusão: Nenhum dos colírios estudados apresentou gotas ideais para o olho humano, levando a um desperdício do produto e maior custo para o fabricante e para o consumidor. Percebemos que existe uma variação significativa no volume da gota de acordo com a inclinação do frasco, e que uma variação maior do que 10% traria impactos financeiros para o paciente.
ABSTRACT Objective: To determine the mean drop volume produced by artificial tear solutions in different inclination angles and to determine the mean cost of the treatment. Methods: The drop volume of 3 original bottles of the artificial tear solutions Artelac®, Hylo Comod®, Lacrima® Plus, Systane® UL, Lacrifilm®, Hyabak®, Lacribell®, Ecofilm®, Mirugell®, Plenigell®, Fresh Tears®, Optive® and Endura® were determined at the inclination of 90º and 45º. The mean number of drops in each bottle was determined and a pharmacoeconomic evaluation of the drops was made. Results: The drop volume ranged from 32.2 to 64.0 µL at 45º and from 29.1 to 65.1 µL at 90º. The difference between drops in each inclination varied from 2 to 24%. The annual cost was from R$2,73 to R$130,73 according to the inclination of the bottle. The Maximum Duration of Treatment (MDT) was from 29.3 to 51.4 days at 45o and from 28.8 to 48.4 days at 90º, being the difference in MDT from 0.5 to 8 more or less days depending on each brand. Conclusion: None of the collyria studied presented ideal drops for human eyes, leading to a waste of the product and higher cost for the manufacturer and the consumer. We noted that there is a significant variation in the drop volume according to the inclination of the bottle, and that a variation of over 10% would bring financial impact for the patient.